HomeMy WebLinkAboutPLANS Deck 452 Skyline Dr 2024-10-19PERMIT #24-EP-00392 Field Copy Print out legibly & in color and have on-site for inspector REVIEWED BY SAFEbuilt - 10/9/2024 - BY PBland SITE PLAN REVIEWED FOR BUILDING COMPLIANCE NO PORTION OF ANY BUILDING OR STRUCTURE SHALL ENCROACH INTO OR OVER AN EASEMENT LINES ISOLATED FOOTING SCALE 1/2"=1'-0" POST TO BEAM 3 DETAIL SCALE 1"=1'-0" POST TO BEAM 2 DETAIL SCALE 1" = 1'-0" POST TO BEAM 1 DETAIL SCALE 1"=1'-0" ALL INFORMATION ON THESE DRAWINGS ARE THE INTELLECTUAL PROPERTY OF SKY POND ENGINEERING AND MAY NOT BE REUSED OR DISTRIBUTED WITHOUT THE COMPANY'S CONSENT. DE C K D R A W I N G S 45 2 S K Y L I N E D R I V E , E S T E S P A R K , C O , 8 0 5 1 7 300 E. Elkhorn, Estes Park, CO, 80517 504-940-8278 REV DATE COMMENT PERMIT SET09/19/240 SHEET NUMBER: POJECT NUMBER: 24138E S1 SITE & LOAD INFORMATION 1. CODE: 2021 INTERNATIONAL RESIDENTIAL CODE 2. SITE ELEVATION: 7,511 FT. 3. EXPOSURE CATEGORY: B 4. FROST DEPTH:30IN 5. GROUND SNOW LOAD: 65 PSF 6. LIVE LOAD: 40 PSF 7. DEAD LOAD: 10 PSF 8. ULTIMATE WIND SPEED: 175 MPH 9. ALLOWABLE BEARING PRESSURE: 2,500 PSF. GENERAL 1. ALL WORK SHALL BE DONE IN CONFORMANCE WITH THE 2021 INTERNATIONAL RESIDENTIAL CODE. 2. ENGINEERING SCOPE IS TO PROVIDE STRUCTURAL DRAWINGS FOR TWO DECKS. 3. ONLY THE FINAL REVISION OF THIS DRAWING SHALL BE USED FOR CONSTRUCTION. IT IS THE BUILDERS RESPONSIBILITY TO ENSURE IT HAS THE FINAL REVISION. 4. DETAIL DRAWINGS SUPERCEDE ANY VISUAL APPEARANCE IN THE MAIN SECTION AND PLAN VIEWS. 5. ALL FIELD MEASUREMENTS TO BE VERIFIED BY CONTRACTOR BEFORE CONSTRUCTION. 6. IT IS THE OWNER'S RESPONSIBILITY TO CONFIRM THE ALLOWABLE BEARING PRESSURE, WHICH HAS NOT BEEN BASED ON A GEOTECHNICAL STUDY, AND IS ASSUMED AT 2,500 PSF. CONCRETE 1. ALL CONCRETE DESIGN IS BASED ON ACI318 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. 2. CONCRETING FORMING PROCEDURES SHALL BE USED IN ACCORDANCE WITH ACI. 3. ALL STRUCTURAL CONCRETE SHALL HAVE MINIMUM 28-DAY COMPRESSIVE STRENGTHS AT 3,500 PSI. 4. CONCRETE SHALL BE PROPORTIONED USING TYPE I/II CEMENT. CONCRETE SUSCEPTIBLE TO FREEZING SHALL BE FORMULATED FOR MAXIMUM FROST RESISTANCE IN ACCORDANCE WITH ACI. 5. ALL EXPOSED EDGES AND CORNERS SHALL BE CHAMFERED MIN. 3/4". 6. ALL EXTERNAL FOOTINGS SHALL REACH A DEPTH OF 30" FOR FROST. 7. FOOTINGS THAT LAND ON BEDROCK SHALL BE DOWELED W/ (4) #4 VERTICAL MINIMUM OF 8" INTO BOTH ROCK AND CONCRETE, EPOXIED TO THE BEDROCK. 8. ALL POST BASES SHALL BE ABA SIMPSON STRONG TIE AND INSTALLED PER MANUFACTURER INSTRUCTIONS, U.N.O. REINFORCING STEEL 1. ALL FABRICATION AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI318 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. 2. REINFORCING BARS SHALL CONFORM TO ASTM A615 AND SHALL BE GRADE 60. 3. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 3" CLEAR FROM BOTTOM OF CONCRETE FOOTING, 2" ELSEWHERE, U.N.O. STRUCTURAL WOOD FRAMING 1. ANY NON-DETAILED CONNECTIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2021. CONTACT ENGINEER FOR ANY CLARIFICATIONS. 2. ALL ENGINEERED WOOD PRODUCTS SHALL BE DESIGNED AND INSTALLED PER MANUFACTURER. 3. ALL LUMBER, FLOOR JOISTS, AND POSTS SHALL BE DOUGLAS FIR-LARCH NO. 2 AND BETTER, U.N.O. 4. ALL EXTERIOR TREADS SHALL BE DOUGLAS FIR NO.1 OR BETTER. PRESSURE TREATMENT AND SEALING IS ALLOWED U.N.O. 5. PROVIDE BLOCKING AT BEARING LOCATIONS OF JOISTS & BUILT-UP COLUMNS. 6. SIMPSON HANGERS SHALL BE LU210 OR EQUIVALENT AT ALL 90° CONNECTIONS @ 2X JOISTS, LSSJ HANGERS AT ALL 0 - 45° CONNECTIONS @ 2X JOISTS, AC CAP @ POST-BEAM CONNECTIONS, AND LPCZ CAP @ BEAM-BEAM CONNECTION U.N.O. 7. AT ALL BEARING LOCATIONS FOR JOISTS SIMPSON H2.5A SHALL BE USED. 8. SIMPSON HL CONNECTOR SHALL BE PROVIDED AS BEAM TIE-DOWNS WHERE NESSESARY. 9. DECK SHALL HAVE TOP DECKING RATED JOIST SPANS. 10. DECK MEMBERS SHALL BE PRESSURE TREATED. 11. LEAD HOLES FOR LAG BOLTS AND SCREWS SHALL BE DRILLED IN ACCORDANCE WITH THE AITC TIMBER CONSTRUCTION MANUAL. 12. DECKING AND RAILING NOT SHOWN FOR CLARITY. 13. LEDGERS SHALL MATCH JOIST DEPTHS W/ 3-5/8" LEDGERLOKS @ 8" STAGGERED VERTICALLY (REF. R507.9.1.3(1) IRC). 14. ALL HARDWARE SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS. 15. SIMPSON STRONG TIE HANGERS AND CONNECTORS SHALL BE USED FOR ALL CONNECTIONS, U.N.O. 16. RAIL SYSTEMS SHALL BE IN ACCORDANCE WITH 2021 IRC R507.10. 17. STAIR SYSTEMS SHALL BE IN ACCORDANCE WITH 2021 IRC R511.7. 2 X 8 J O I S T S @ 1 6 " O .C . 2 X 8 J O I S T S @ 1 6 " O .C . EXISTING HOUSE ( 2 ) 2 X 8 B E A M ( T Y P.) 2X8 LEDGER (TYP.) N (2) 2X10 BEAM (TYP.) 2 X 1 0 J O I S T S @ 1 6 " O .C . (3) 2X8 BEAM EXISTING HOUSE 2X10 LEDGER (TYP.) N (2 ) 2 X 1 0 (2) 2 X 1 0 FRONT DECK FRAMING PLAN SCALE 1/4"=1'-0" 2X6 WALL 2X10 JOIST FLASHING 1/2" LAG SCREWS OR LEDGERLOCKS LU210 SIMPSON HANGER SHEATHING DECKINGEXISTING FLOOR 5 1/2" 2" DTT1Z SIMPSON HOLD-DOWN DEVICE MIN. 750LB CAPACITY AT 4 LOCATIONS EVENLY DISTRIBUTED ALONG DECK AND ONE WITHIN 24" OF EA. END OF THE LEDGER. HOLD-DOWN DEVICES SHALL FULLY ENGAGE DECK JOIST PER HOLD-DOWN MANUFACTURER ALL FULLY THREADED 3/8" LAG SCREW PREDRILLED W/ MIN. 3" PENETRATION TO CENTER OF TOP PLATE, STUDS, OR HEADER DECK CONNECTION DETAIL SCALE: 1" = 1' - 0" ABA SIMPSON POST BASE 6X6 POST OR (2) 2X8 BEAM #4 VERT. 2'-6" ISOLATED FOOTING REBAR SCHEDULE Diameter Vertical rebar <18"3 18"-36"5 >36"6 BLOCKING LPC6Z SIMPSON POST CAP (3)2X8 BEAMH2.5A SIMPSON HURRICANE TIE 2X10 JOIST 6X6 POST 6X6 POST (2) 2X10 BEAM/ (2) 2X8 BEAM(2)1/2" THRU BOLTS(2) 2X10 BEAM (2)2X10 JOIST LU210 SIMPSON HANGER JOIST TO BEAM DETAIL SCALE: 1" = 1' - 0" EXISTING POST 1'-0" 1'-0"1'-0" 1'-0" 1'-0"1'-2"1'-0"1'-0"1'-0" 1'-0" 1'-0"1'-8"1'-8" 10'-6 3/4"6'-9 1/2" BACK DECK FRAMING PLAN SCALE 1/4"=1'-0" EXISTING POST (2) 2X8 BEAM 5'-1 1/2" 14'-10"3'-1"4'-5"2'-8" 6'-0" 8'-0" 10'-3"4'-11" 5'-7" 4'-11" 6'-3" 7'-2 1/4" 5'-9 3/4" (2) 1/2" THRU BOLTS SEE FRAMING PLAN FOR DIMENSIONS HUC210-2 SIMPSON HANGER 09/19/24 PERMIT #24-EP-00392 Field Copy Print out legibly & in color and have on-site for inspector REVIEWED BY SAFEbuilt - 10/9/2024 - BY PBland Connectors & fasteners in contact with preservative-treated wood shall be of hot dipped, zinc coated galvanized steel, stainless steel, silicone bronze or copper ALL BEAM/JOIST SPLICES MUST OCCUR OVER POST/SUPPORT WITH 1 1/2" BEARING Plastic composite decking, treads and handrail to comply with R507.2.2 & bear a label of compliance with ASTM D7032. Verify composite decking can span the required joist spacing - per manufacturers installation instructions & specifications. Verify span of joists for wood decking material with Table R507.7 OPEN HOLE INSPECTION REQUIRED FOR DEPTH & SIZE OF CAISSONS/PIERS - BEFORE CONCRETE IS POURED CAISSONS/FOOTERS SHALL BE SUPPORTED ON UNDISTURBED NATURAL SOILS OR COMPACTED ENGINEERED FILL - PER 403.1 Wood materials used to be Preservative-treated or approved Naturally durable wood in accordance with Section R317 & AWPA U1 - Unless noted otherwise on this drawing Ends of joists, rafters, beams or girders shall have not less than 1 1/2" of bearing on wood or metal - 3" min. on masonry or concrete per R502.6 & R802.6 GUARDRAILS FOR 2021 IRC R507.10.1Support of guards - Where guards are supported on deck framing, guard loads shall be transferred to the deck framing with a continuous load path to the deck joists. R507.10.1.1Guards supported by side of deck framing - Where guards are connected to the interior or exterior side of a deck joist or beam, the joist or beam shall be connected to the adjacent joists to prevent rotation of the joist or beam. Connections relying only on fasteners in end grain withdrawal are not permitted. R507.10.1.2Guards supported on top of deck framing - Where guards are mounted on top of the decking, the guards shall be connected to the deck framing or blocking and installed in accordance with manufacturer’s instructions to transfer the guard loads to the adjacent joists. R507.10.2Wood posts at deck guards - Where 4-inch by 4-inch (102 mm by 102 mm) wood posts support guard loads applied to the top of the guard, such posts shall not be notched at the connection to the supporting structure. R507.10.3Plastic composite guards - shall comply with the provisions of Section R507.2.2. R507.10.4Other guards - shall be in accordance with either manufacturer’s instructions or accepted engineering principles. DECK - Min. Stair / Handrail Rqmts (R311.7 ): 1. Stairways to be not less than 36" in width 2. Risers = 7 3/4" max 3. Treads = 10" min. 4. The length of Run and the height of Riser shall not vary more than 3/8" in the entire run of the stair. 5. Stairs are required to be illuminated 6. Open risers opening = less than 4" 7. Nosing = 3/4" min. 8. Handrail reqd for 4 or more risers 9. Handrail = 34" min. - 38" max 10. Handrail to be continuous one side min. 11. Hand-grip = 1-1/4" min to 2" max 12. Handrails to return to wall, post or terminal AP P R O V E D b y S A F E b u i l t ; 20 2 1 I n t e r n a t i o n a l C o d e s Su b j e c t t o i n s p e c t i o n a n d c o m p l i a n c e t o a l l Re l e v a n t , a d o p t e d B u i l d i n g & M u n i c i p a l Co d e s 10 / 0 9 / 2 0 2 4