HomeMy WebLinkAboutPLANS Basement Remodel 174 Stanley Circle Dr 2021-09-28PERMIT #21EP-00454
Field Copy
Subject to Field
Inspections
PLANS AND CONSTRUCTION SHALL MEET THE 2015
IRC AND ALL APPLICABLE FOR THE TOWN OF ESTES
PARK MUNICIPAL CODES & ORDINANCES
DO NOT COVER WORK UNTIL IT HAS
BEEN APPROVED BY INSPECTION -
IF YOU HAVE FAILED A ROUGH
INSPECTION YOU MUST HAVE AN
APPROVED REINSPECTION BEFORE
YOU COVER THE WORK UP.
REVIEWED BY
PAMELA BLAND
The entire building must be
provided with Smoke Detectors
located as required by code.
CO Detectors are Required wihtin
15 ft. of ALL Bedrooms
Drywall under stairs Min
1/2" if enclosed as storage
Minimum ceiling height is 7’0”,
under beams & ducts 6’-4” is
permissible
All habitable space requires
heat supply and pressure
relief.
Basement Finish Insulation:
Continuous Insulation = R15
OR
Cavity framing Insulation = R19
on exterior walls
Cement based substrate or equal
on shower walls
Maintain 30" clear working space in
front of mech applicances for work
access
Toilets & Lavatories shall be provided with
a min. of 21 inches in front each fixture
- each side of Toilets shall have 15 inches
from the center line of the toilet and any
sidewall or other obstructions.
Provide 50 cfm fan in
bathroom - vented to exterior
- when no natural ventilation
is provided by window
Min. one window &
well to meet egress
requirements
Showers - min. inside dim. of 900 sq. in. -
finished 72 in. above the floor with a
non-absorbent material. Shower door min.
clear opening width is 22 inches - P2708.1
exception #2 - Shower door clearance 24
inches in front of door opening.
SD/CO
Provide Combustion Air to Mech Rm
- that is obtained from outdoors -
when fuel fire appliances or garage
that communicates with dwelling
SD
Fire Block shall be provided in
wood framed walls per locations
designated in R302.11
PERMIT #21EP-00454
Field Copy
Provide anti-scald valves
on shower or shower/tub
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
09/28/2021
REVIEWED BY
PAMELA BLAND
DO NOT COVER WORK UNTIL IT HAS BEEN
APPROVED BY INSPECTION -
IF YOU HAVE FAILED A ROUGH INSPECTION YOU
MUST HAVE AN APPROVED REINSPECTION
BEFORE YOU COVER THE WORK UP.
When flow velocity needs
to be controlled - like on
washers - water hammer
arrestors shall be
installed in accordance
with manufacturer's
instructions (R2903.5)
Bathroom - 15 & 20 Amp Dedicated
Circuit - GFCI protected - min. one
outlet within 36" of outside edge of
lav. basin per lavatory located on an
adjacent wall.
Arc fault protection required at
electrical openings
Provide Tamper Resistant
Receptacles
Replacement of existing
receptacles outlets shall comply
with NEC 406.4 D 1-6
Laundry areas 15 & 20 amp - GFCI
protected - & not less than one
receptacle outlet to supply the
laundry laundry equipment.
PERMIT #21EP-00454
Field Copy
REVIEWED BY
PAMELA BLAND
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
09/28/2021
DO NOT COVER WORK UNTIL IT HAS BEEN
APPROVED BY INSPECTION -
IF YOU HAVE FAILED A ROUGH INSPECTION YOU
MUST HAVE AN APPROVED REINSPECTION
BEFORE YOU COVER THE WORK UP.
Subject to Field Inspections
PER E4003.11 - LUMINAIRES WITHIN THE ACTUAL OUTSIDE DIMENSION
OF THE BATHTUB OR SHOWER TO A HEIGHT OF 8 FEET VERTICALLY
FROM THE TOP OF THE BATHTUB RIM OR SHOWER THRESHOLD SHALL
BE MARKED FOR DAMP LOCATIONS - WHERE SUBJECT TO SHOWER
SPRAY SHALL BE MARKED FOR WET LOCATIONS.
PER E4002.11 - A RECEPTACLE SHALL NOT BE INSTALLED
WITHIN OR DIRECTLY OVER A BATHTUB OR SHOWER STALL