HomeMy WebLinkAboutPLANS Remodel Cabin 5-6 1750 Fall River Rd 2021-10-06PERMIT #21-EP-00468
Field Copy
Print out in color and have
on site for inspector
Bathrooms - 15 & 20 amp
circuit installed in bathrooms
to be GFCI protected
Arc fault protection required at
electrical openings - except
bathrooms
Provide Tamper Resistant
Receptacles
Replacement of existing
receptacles outlets shall
comply with NEC 406.4
D 1-6
Cement based
substrate or equal on
shower/tub walls
Glazing installed in
hazardous locations
as defined in Section
R308.4 shall be
Tempered Glass
Freeze Protect pipes
per P2603.5
Provide 50 cfm fan in
bathroom - vented to
exterior - when no
natural ventilation is
provided by window
Fire Block shall be provided in wood framed
walls per locations designated in R302.11
Provide Anti-Scald
valves on shower or
tub/shower combination
valves
Toilets & Lavatories & Shower -
See Figure R307.1 for clearances
Showers shall be finished 72" above
floor with non-absorbent material.
Shower door min. clear opening 24"
SD/CO - SD to be installed inside of each separate sleeping area and
outside each door in the immediate vicinity of the bedrooms. (R315.3)
CO must be installed outside each bedroom within 15' of each room
Air gap required at or within dishwasher -
per P2717.1
Appliance and all Equipment
Vent Terminations shall be per
manufacturers specifications
If kitchen hood greater than
400 cfm, must have approx
equal make up air on
automatically controlled
damper - Per M1503.6
Hardwired appliances are
required to have a
disconnect within sight or
a lockable means at
circuit breaker
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
10/06/2021
REVIEWED BY
SAFEBUILT - PBLAND