HomeMy WebLinkAboutPLANS Residential Remodel 1911 Crags Ct 2022-06-0660 V 2/6X6/8 BATH CLOSET BATH CLOSET TLT. REMOVE EXISTING VANITY, TOP AND SINK. MODIFY PLBG. FOR NEW DBL. SINK. REMOVE EXISTING TOILET AND MODIFY PLBG. FOR NEW LOCATION. REMOVE EXISTING TUB/SHOWER AND MODIFY PLBG. FOR NEW SHOWER. REMOVE EXISTING POCKET DOOR AS PER NEW WORK. REMOVE EXISTING CLOSET SHELVING AS NEEDED FOR NEW WORK.REMOVE EXISTING HVAC CHASE AND REWORK DUCT WORK. 2/4X6/8 LI N E N 15" 5S 2R2S 1R1S 34 " 60" SHOWER 12 " NEW 2X4 STUD WALL @ 16" O.C.-TYP. NEW MDF. CLOSET SHELVING. NEW FLOORING THROUGHT. 2/8X7/0 BARN NEW WORK BATH PLAN SCALE: 1/4"= 1'-0" A1.01911 CRAGS CT.BATH REMODEL @ ESTES PARK, COLORADO 80517 EXISTIN / DEMO BATH PLAN SCALE: 1/4"= 1'-0" LEGEND: PERMIT #22-EP-00277 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND Fire Block per section R302.11 All work shall be performed by Licensed Contractors OR by the homeowner residing in the dwelling. SEE HANDOUTS FOR ADDITIONAL CODE NOTES AND GUIDANCE The entire building must be provided with Smoke Detectors/CO Alarms KEEP ALL PERMIT DOCUMENTS TOGETHER & ON-SITE FOR INSPECTORS REVIEW This structure must comply with the requirements of the 2020 National Electrical Code APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 06/06/2022 DO NOT COVER WORK UNTIL IT HAS BEEN APPROVED BY INSPECTION - IF YOU HAVE FAILED A ROUGH INSPECTION YOU MUST HAVE AN APPROVED REINSPECTION BEFORE YOU COVER THE WORK UP - OR INSPECTOR TELLS YOU DIFFERENTLY. GFCI protection shall be provided for lighting outlets install on a wall & switches within 3' horizontally & 8' vertically on wall from the top of the bathtub rim or shower stall threshold - & include space directly above (210.8 - 2020 NEC amendment) BATHROOM CLEARANCES: Toilets - must be provided with a minimum of 21 inches in front of the toilet and lavatory. Toilets must also have 15 inches from the center line of the toilet and any sidewall or other obstructions. Showers – shall have a minimum inside dimension of 900 square inches, capable of encompassing a 30 inch circle and be finished 72 inches above the floor with non- absorbent materials. Shower door minimum clear opening width is 22 inches (see section P2708.1 exception 2) Shower door clearance shall have 24” in front of door opening. - Bathroom - 15 or 20 Amp Dedicated Circuit to be GFCI protected - min. one outlet within 36" of outside edge of lav basin per lavatory located on an adjacent wall. ELECTRICAL NOTES: PER SECTION R307 & TABLE 307.1 - Exterior walls adjacent to showers and tubs shall provide air barrier & insulated. See Table N1102.4.1.1 - Cement based substrate or equal on shower/tub walls - Freeze Protect pipes per P2603.5 - Provide 50 cfm fan in bathroom - vented to exterior - when no natural ventilation is provided by window - Provide Anti-Scald Valve on shower PLAN REVIEW NOTES -- RELATED TO BATHROOM DO NOT COVER WORK UNTIL IT HAS BEEN APPROVED BY INSPECTION - IF YOU HAVE FAILED A ROUGH INSPECTION YOU MUST HAVE AN APPROVED REINSPECTION BEFORE YOU COVER THE WORK UP - OR INSPECTOR TELLS YOU DIFFERENTLY.