HomeMy WebLinkAboutPLANS Residential Remodel 905 Elk Ridge Ct 2022-06-20DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
GENERAL PROJECT NOTES AND INFORMATIONPROPERTY INFORMATION
ADDRESS:905 ELK RIDGE CT
ESTES PARK, CO 80517
PARCEL:2531212012
ZONING:E - ESTATE (1/2 ACRE)
DISTRICT:3300
JURISDICTION:TOWN OF ESTES PARK
LOT SIZE:0.44 ACRES
TYPE:RESIDENTIAL
OCCUPANCY:SINGLE FAMILY
YEAR BUILT:2002
REMODELED:NONE
TOTAL AREA:1280 MAIN, 1280 BASEMENT
ELECTRIC:ESTES PARK L&P
WATER:ESTES PARK
SEWER:E.P.S.D.
GAS:EXCEL
INTERNET:UNKNOWN
1) THESE DRAWINGS ARE BASED UPON FIELD MEASUREMENTS. ALL DIMENSIONS MUST BE VERIFIED IN FIELD PRIOR TO ANY
DEMOLITION, CONSTRUCTION, OR ORDERING OF MATERIALS.
2) ALL DIMENSIONS ARE FROM FACE OF STRUCTURE TO FACE OF STRUCTURE, UNLESS NOTED OTHERWISE.
3) THIS IS A REMODEL / ADDITION TO AN EXISTING STRUCTURE AND DIMENSIONS MAY NEED TO BE ADJUSTED IN FIELD.
4) ALL DIMENSIONS MARKED WITH ± ARE APPROXIMATE.
5) INSPECT AND VERIFY EXISTING CONDITIONS. NOTIFY G.C. OF ANY DISCREPANCIES OR QUESTIONS.
6) ALL WORK SHALL COMPLY WITH LOCAL CODES AND REGULATIONS.
7) MAINTAIN A CLEAN AND SAFE WORK-SITE AT ALL TIMES. CLEAN UP CONSTRUCTION DEBRIS ON A REGULAR BASIS.
8) ALL NEW WINDOWS AND DOORS SHALL BE SIZED FOR AND INSTALLED WITHIN EXISTING OPENINGS, UNLESS NOTED
OTHERWISE.
REMOVE
EXISTING
SHOWER
REMOVE
EXISTING
WALLS
AND DOOR
AS SHOWN
REMOVE
EXISTING
TOILET AND
REINSTALL IN
NEW LOCATION
REMOVE
EXISTING
WALL AS
SHOWN
EXISTING VANITY
TO REMAIN
REMOVE EXISTING WINDOWS.
FRAMED OPENINGS TO REMAIN
AND FILLED IN AS SHOWN ON SHEET A2
REMOVE
EXISTING
TUB
EXISTING DOORS AND WALLS
TO REMAIN AS SHOWN
PREPARE FLOOR FOR NEW TILE
OTHER NOTES AND INFORMATION
EXISTING
COLOR KEY
NEW
DEMOLITION
BY OWNER
A1
06 / 07 / 2022
N
E
I
L
&
J
O
Y
C
E
J
O
H
N
S
O
N
BA
T
H
R
O
O
M
R
E
M
O
D
E
L
90
5
E
L
K
R
I
D
G
E
C
T
-
E
S
T
E
S
P
A
R
K
,
C
O
8
0
5
1
7
OF 2
SHEET NUMBER
ISSUE DATE
REVISIONS
PROJECT INFO AND
DEMOLITION PLAN
SHEET TITLE
-
-
-
CLIENT APPROVED
PERMIT
APPLICATION SET
PROVIDE THE IN FLOOR
HEATING SPECS ON SITE
FOR THE INSPECTOR
ELECTRICAL CODE
COMPLIANCE TO BE
VERIFIED ON SITE BY
INSPECTOR
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
06/20/2022
This structure must comply
with the requirements of the
2020 National Electrical Code
Reviewed by
SAFEbuilt
06/20/2022
PRINT PLANS IN COLOR AND HAVE FOR
INSPECTOR AT TIME OF INSPECTION
PROPOSED FLOOR PLAN
SCALE: 1/2" = 1'-0"
ELECTRICAL AND LIGHTING
SCALE: 1/8" = 1'-0"
4'-0" MIN CLEAR
REINSTALL EXISTING
TOILET IN NEW LOCATION 2'-6" DOOR
GLASS PANEL
FLOOR TO CEILING
NICHE
SIZE
T.B.D.
DRAIN
24" x 36" WINDOW
TEMPERED
24" x 36" WINDOW
TEMPERED
4 OR 5
SHELVES
16" DEEP3'
-
6
"
C
L
E
A
R
3'
-
0
"
EXISTING
VANITY
TO REMAIN
2'-0"
EXISTING DOORS
TO REMAIN
FILL IN REMAINING OPENING
IN EXISTING WALL FRAMING
FOR SMALLER WINDOW
NEW TILE FLOOR
WITH IN-FLOOR HEAT
THERMOSTAT AND WIRING
FOR IN-FLOOR HEAT
NEW TILE FLOOR
WITH IN-FLOOR HEAT
2x4 WALLS
16" O.C.
2x6 WALL
16" O.C.
24" GRAB-BAR
VERTICAL
36" GRAB-BAR
HORIZONTAL
FOOT NICHE
SHAVING
SHELF
36" GRAB-BAR
HORIZONTAL
A2
06 / 07 / 2022
N
E
I
L
&
J
O
Y
C
E
J
O
H
N
S
O
N
BA
T
H
R
O
O
M
R
E
M
O
D
E
L
90
5
E
L
K
R
I
D
G
E
C
T
-
E
S
T
E
S
P
A
R
K
,
C
O
8
0
5
1
7
OF 2
SHEET NUMBER
ISSUE DATE
REVISIONS
PROPOSED FLOOR
PLAN
SHEET TITLE
-
-
-
CLIENT APPROVED
PERMIT
APPLICATION SET
MUST PASS SHOWER
LINE TEST
TEMPORARY SHORING
MAY BE REQUIRED
Reviewed by
SAFEbuilt