Loading...
HomeMy WebLinkAboutPLANS PV System 333 Ute Ln 2024-04-25814 E 1475 N Lehi, UT 84043 m: (309) 645-0999 Solar Professional Engineering Consulting 2024.03.12 admin@lucenteng.co Redrocks Roof and Solar LLC 3514 W 29th Ave, Apt 4 Denver, CO 80211 RE: Engineering Services Rupp Residence 333 Ute Ln, Estes Park, CO 7.6 kW System Solo Job #4432492 To Whom It May Concern, A. Assumptions from Field Observation provided by Redrocks Roof and Solar LLC Roof Roof B Roof Finish :Asphalt Shingle Asphalt Shingle Roof Underlayment :OSB OSB Roof Profile :Gable Gable Roof Structural System :Metal Plate Trusses Metal Plate Trusses Truss Top Chord/Setup :2 x 4 / Fink 2 x 4 / Fink Chord/Rafter Wood Grade : Truss/Rafter Spacing :24'' o.c.24'' o.c. Roof Slope :23 deg 23 deg Max Top Chord/Rafter Span :7.32 ft 7.32 ft Bearing Wall Type : Convl Lt-Frame Constr CLFC Foundation : Permanent Concrete Permanent Concrete Stories : Two Single B. Building Design Criteria Code : 2021 IRC (ASCE 7-16) Risk Category : II Roof Live Load : 20 psf (0 psf at panels) Occupancy Class : R-3 Ground Snow Load : 72 psf Roof Dead Load : 6.5 psf Ult Wind Speed : 175 mph PV Dead Load : 3 psf Exposure Category : C Total Dead Load : 9.5 psf C. Summary of Existing Structure Results Roof - Adaquate to support the additional imposed loads. No structural upgrades are required. Lucent Engineering, P.C. April 17, 2024 We have reviewed the following information regarding the solar panel installation for this project. Alterations to these documents or plans shall not be made without direct written consent of the Engineer of Record. The following structural design regarding the proposed alterations have been prepared from these assumptions. The verification of the field observations is the responsibility of the contractor. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the sealed plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies. After review of the field observations and based on our calculations and in accordance with the applicable building codes and current industry standards, the existing roof structure supporting the proposed alterations consisting of the solar array has been determined to be: Spruce-Pine-Fir MSR 1650f-1.5E or better Nicholas J Bowens Digitally signed by Nicholas J Bowens DN: CN=Nicholas J Bowens, dnQualifier=A01410D0000018B9785AC0B0001555A, O=LUCENT ENGINEERING P.C., C=US Date: 2024.04.17 21:49:45-06'00' REVIEWED BY SAFEBUILT 04/25/2024 D. Solar Panel Support Bracket Anchorage 1. 2. Manufacturer's Panel Bracket Connection to Roof Chord/Rafter Member: Fastener : (2) #14 SS Screws per Bracket NDS Withdrawl Value : 157 lbs/inch Min. Thread Length and Pentration Depth : 2.5'' 3. 4. E. Overall Summary Sincerely, Nicholas J. Bowens, PE License No. 61540 Limits of Scope of Work and Liability Page 2 of 2 Rupp Residence Should you have any questions regarding this letter or if you require further information, do not hesitate to contact me. Considering the existing roof's slope, size, spacing, condition, and calculated loads, the panel bracket supports shall be placed no greater than 48 in. o/c. Panel supports connections shall be staggered to distribute load to adjacent trusses. Solar panels shall be designed, mounted, and installed in accordance with the most recent ''Ironridge Manual'', which can be found on the Ironridge website (http://ironridge.com). Based on the information supplied to us at the time of this report, on the evaluation of the existing structure, and solar array panel bracket connection, it is our opinion that the roof system will adequately support the additional loads imposed by the solar array. This evaluation conforms to 2021 IRC and current industry standards. The existing structure is assumed to have been designed and constructed following appropriate codes at the time of erection and assumed to have appropriated permits. The calculations performed are only for the roof framing supporting the solar array installation referenced in the stamped plans and were completed according to generally recognized structural analysis standards and procedures, professional engineering, and design experience opinions and judgements. Existing deficiencies which are unknown or were not observed during the time the site observation are not included in this scope of work. All solar panel modules, racking, and mounting equipment shall be designed and installed per the manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and/or certification letter and notify the Engineer of Record of any discrepancies prior to starting construction. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. The contactor shall also verify that there are no damage/deficiencies (i.e., dry rot, water damage, termite damage, framing member/connection damage, etc.) to framing that was not addressed in the stamped plans, calculations, and/or certification letter and notify the Engineer of Record of any concerns prior to starting construction. Lucent Engineering, P.C.April 17, 2024 04/17/24 REVIEWED BY SAFEBUILT 04/25/2024 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 J.L.ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: STREET VIEW: COVER - PV01 PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS ELECTRICAL EQUIPMENT PV MODULES: (18) HANWHA Q.PEAK DUO BLK ML-G10 400 DC SYSTEM SIZE 7.2 KW DC INVERTER(S): (1) SOLAREDGE SE7600H-US (240V) AC SYSTEM SIZE 7.6 KW AC (18) SOLAREDGE S440 OPTIMIZERS RACKING RACKING: IRONRIDGE XR-100 ATTACHMENT: QUICKMOUNT HALO ULTRAGRIP WITH RD STRUCTURAL SCREWS APPLICABLE GOVERNING CODES 2023 NEC 2021 IBC 2021 IRC 2021 IFC SITE SPECIFICATIONS OCCUPANCY: R-3 ZONING: RESIDENTIAL WIND SPEED: 175 mph SNOW LOAD: 72 lb/ft2 EXPOSURE CATEGORY: B STREET VIEW AERIAL VIEW PV01 COVER PV02 SITE PLAN PV03 ROOF PLAN PV04 MOUNTING DETAIL PV05 LINE DIAGRAM PV06 ELECTRICAL CALCS PV07 LABELS PV08 PLACARD PV09 SITE PHOTOS PV09.1 ELEVATION DETAIL SHEET INDEX GENERAL NOTES 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE 04/17/24 SAFEbuilt APPROVED Subject to inspection and compliance to all relevant Adopted Building and Municipal codes. Changes in Plans MUST be approved. D.GRAHAM 04/25/2024 2021 I-CODES 2021 IECC 24-ep-00107 PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION ALL APPROVED OR REVISED DOCUMENTS SHALL BE PRINTED ON A MINMUM 11X17 PAPER PLAN REVIEWED FOR STRUCTURAL ONLY BY SAFEBUILT ELECTRICAL INSPECTIONS AND PLAN REVIEWS (IF REQUIRED) PER THE STATE OF COLORADO. JB ACINV JB JB M MSP ACINV AC JB J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK ARRAY DETAILS: MOUNTING PLANE:AZIMUTH:TILT: MP1 275° 23° MP2 95° 23° CLOSE UP OF HOME VISIBLE, LOCKABLE, LABELEDAC DISCONNECT LOCATEDWITHIN 10' OF UTILITY METER SITE PLAN - PV02 EQUIPMENT LEGEND: INVERTERVISIBLE, LOCKABLE, LABELEDAC DISCONNECT METER SOCKET (FOR UTILITY PV METER) UTILITY METER MAIN SERVICE PANEL LC LOAD CENTER FIRE ACCESS PATHWAY (3' TYP) C INV PV AC MSP M COMBINER BOX PROPERTY LINEBATTBATTERY(IES) SUB SUB PANEL SD SERVICE DISCONNECT JB JUNCTION BOX PV MODULES 33 3 U t e L n 190'-10" 190'-9" 188'-11" 120'-10" FR O N T O F H O M E DR I V E W A Y MP1 TRENCHING THROUGH CONCRETE APPROX: 30' 18" MIN DEPTH PVC SCH40 MP2 04/17/24 REVIEWED BY SAFEBUILT 04/25/2024 JB M MSP ACINV AC JB J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: EQUIPMENT INFORMATION:ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA RACKING MANUFACTURER: IRONRIDGE ROOF TYPE: ASPHALT SHINGLE PV MODULE COUNT: 18 RACKING PART NUMBER: XR-100 ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA:MODULE COUNT * 21.14 ft² = 380.52 ft² ATTACHMENTS:QUICKMOUNT HALO ULTRAGRIP WITH RD STRUCTURAL SCREWS RAFTER/TOP CHORD SIZE:2x4 ROOF AREA:1934 ft² ATTACHMENT QTY:29 RAFTER/TOP CHORD SPACING:24"PERCENT OF ROOF COVERED: 20% SPLICE QTY:6 ATTACHMENT SPACING 48" ARRAY WEIGHT:MODULE COUNT * 48.5 lbs = 873 lbs MIDCLAMP QTY:30 POINT LOAD:ARRAY lbs/ATTACHMENT QTY = 30.1 lbs ENDCLAMP QTY:12 DISTRIBUTED LOAD: (lbs/ft²)ARRAY WEIGHT/AREA = 2.29 lbs/ft² SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK ATTACHMENT LEGEND: ATTACHMENTS SPLICE RAILING ROOF PLAN - PV03 3'-0" 4'-0" 3'-0" 04/17/24 REVIEWED BY SAFEBUILT 04/25/2024 RAIL (E) COMP SHINGLE ROOF (1 LAYER) ATTACHMENT PV MODULE (E) RAFTER/TOP CHORD DETAIL, MOUNTING AND FLASHING RD STRUCTURAL SCREW PN RD-1430-01-M1 WITH 2-1/2" MIN. EMBEDMENT (PER MANUFACTURER) 4" RAIL 2.5" MIN. EMBED. FLASHING (SEE DATASHEET FOR DETAILS) RAIL 1" PV MODULE FRAME RAIL ATTACHMENT 3 RAIL PV MODULE MAX SPAN1'-8" MAX. 21 FRONT VIEW 10" MIN - 1'-4" MAXPortrait: 2'-8" MIN - 3'-10" MAX Landscape: 1'-2" MIN - 2'-0" MAX 10" MIN - 1'-4" MAX SIDE VIEW3 (E) RAFTER/TOP CHORDS (E) RAFTER/TOP CHORD END CLAMP DETAILS MID CLAMP DETAILS21 END CLAMP MID CLAMP Portrait: 2'-8" MIN - 3'-10" MAX Landscape: 1'-2" MIN - 2'-0" MAX J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: EQUIPMENT INFORMATION:ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA RACKING MANUFACTURER: IRONRIDGE ROOF TYPE: ASPHALT SHINGLE PV MODULE COUNT: 18 RACKING PART NUMBER: XR-100 ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA:MODULE COUNT * 21.14 ft² = 380.52 ft² ATTACHMENTS:QUICKMOUNT HALO ULTRAGRIP WITH RD STRUCTURAL SCREWS RAFTER/TOP CHORD SIZE:2x4 ROOF AREA:1934 ft² ATTACHMENT QTY:29 RAFTER/TOP CHORD SPACING:24"PERCENT OF ROOF COVERED: 20% SPLICE QTY:6 ATTACHMENT SPACING 48" ARRAY WEIGHT:MODULE COUNT * 48.5 lbs = 873 lbs MIDCLAMP QTY:30 POINT LOAD:ARRAY lbs/ATTACHMENT QTY = 30.1 lbs ENDCLAMP QTY:12 DISTRIBUTED LOAD: (lbs/ft²)ARRAY WEIGHT/AREA = 2.29 lbs/ft² SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK MOUNTING DETAIL - PV04 04/17/24 REVIEWED BY SAFEBUILT 04/25/2024 1Ø, 120/240 VAC TO UTILITY GRID (E) UTILITY METER 3 (E) LOADS N G (N) 40A-2P (N) 200A-2P (N) 225A EXTERIOR MAIN SERVICE PANEL AND SERVICE DISCONNECT NEW MAIN SERVICE PANEL TOBE INSTALLED IN COMPLIANCEWITH NEC 230.85 AND 230.67 (E) GROUNDINGELECTRODE L1 L2 N G SOLAREDGE SE7600H-US (240V) UL 1741 COMPLIANTINTEGRATED RAPID SHUTDOWN DC DISCONNECT AC DC GND 1 ====== STRING (1) 1 ====== STRING (2) NEMA 3R J-BOX 2 8 MODULES 10 MODULES (N) PV AC DISCONNECT 60A NON-FUSED, VISIBLE, LOCKABLE,LABELED, OPEN240V, 2-POLE 4 (N) PV AC DISCONNECT 60A NON-FUSED, VISIBLE, LOCKABLE,LABELED, OPEN240V, 2-POLE 3 J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF UTILITYMETER LINE DIAGRAM - PV05 SOLAREDGE SE7600H-US (240V) SPECS MAX INPUT VOLTAGE: 480 V MAX INPUT CURRENT: 20 A MAXIMUM OUTPUT POWER: 7600 W MAXIMUM OUTPUT CURRENT: 32 A NOM. OUTPUT VOLTAGE: 240 V 1-PHASE, 60 Hz, UL 1741 LISTED HANWHA Q.PEAK DUO BLK ML-G10 400 SPECS POWER MAX (PMAX):400 W OPEN CIRCUIT VOLTAGE (VOC):45.3 V MAX POWER-POINT CURRENT (IMP):10.77 A MAX POWER-POINT VOLTAGE (VMP):37.13 V SHORT CIRCUIT CURRENT (ISC):11.14 A SERIES FUSE RATING: 20 A EQUIPMENT SCHEDULE PV MODULES:(18)HANWHA Q.PEAK DUO BLK ML-G10 400 400 W INVERTERS:(1) SOLAREDGE SE7600H-US (240V)7600 W AC DISCONNECT(S): (2)PV AC DISCONNECT, 240V, 2-POLE 60 A OPTIMIZER(S): (18)SOLAREDGE S440 15 A TAG CONDUCTOR DETAILS GROUND DETAILS CONDUIT SIZE 1 (2) 10 AWG PV-WIRE, USE-2 COPPER (1) 6 AWG BARE COPPER N/A - FREE AIR 2 (4) 10 AWG THHN/THWN-2 COPPER (1) 10 AWG THWN-2 COPPER 3/4" EMT 3 (3) 8 AWG THWN-2 COPPER (1) 10 AWG THWN-2 COPPER 3/4" EMT 4 (3) 8 AWG THWN-2 COPPER (1) 10 AWG THWN-2 COPPER 1.5" PVC-40 (Trenching) *LOAD SIDE CONNECTION* NEC 705.12(B) TRENCHING THROUGH CONCRETE APPROX: 30' 18" MIN DEPTH PVC SCH40 INTERACTIVE SYSTEM TYPE 04/17/24 ELECTRICAL INSPECTIONS AND PLAN REVIEWS (IF REQUIRED) PER THE STATE OF COLORADO. J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK SYSTEM OCPD CALCULATIONS INVERTER MODEL(S): SOLAREDGE SE7600H-US (240V) # OF INVERTERS:1 MAX OUTPUT CURRENT: 32A (MAX OUTPUT CURRENT) X 125% ≤ OCPD RATING (32A) X 1.25 = 40 ≤ 40A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES 4-6 .80 7-9 .70 10-20 .50 GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: DISCONNECT NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.41] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAKSWITCH STRING CALCULATIONS MAXIMUM STRING CALCULATION MODULES IN SERIES: 10 NOMINAL STRING VOLTAGE: 400 V MAX STRING OPERATING CURRENT: 10.00 A MAX STRING DC POWER: 4000 W ELECTRICAL CALCS - PV06 MAIN PANEL UPGRADE MAIN BUSBAR RATING: 225 A MAIN DISCONNECT RATING: 200A PV OCPD RATING: 40 A (MAIN BUS RATING X 120%) - MAIN DISCONNECT RATING >= OCPD RATING (225A X 1.2) - 200A = 70A, ≥ 40A, OK TAG CONDUCTOR DETAILS GROUND DETAILS CONDUIT SIZE CONDUCTOR RATING AMBIENTTEMP DEGREE COLUMN TEMPDERATE # OF CONDUCTOR DERATE CONDUCTOR RATING W/ DERATES CONDUIT FILL 1 (2) 10 AWG PV-WIRE, USE-2 COPPER (1) 6 AWG BARE COPPER N/A - FREE AIR 40 A 34°C 90°C 0.96 1 38 A N/A - FREE AIR 2 (4) 10 AWG THHN/THWN-2 COPPER (1) 10 AWG THWN-2 COPPER 3/4" EMT 40 A 34°C 90°C 0.96 0.8 31 A 19.8% 3 (3) 8 AWG THWN-2 COPPER (1) 10 AWG THWN-2 COPPER 3/4" EMT 50 A 34°C 75°C 0.94 1 47 A 24.6% 4 (3) 8 AWG THWN-2 COPPER (1) 10 AWG THWN-2 COPPER 1.5" PVC-40 (Trenching)50 A 34°C 75°C 0.94 1 47 A 6.6% ELECTRICAL INSPECTIONS AND PLAN REVIEWS (IF REQUIRED) PER THE STATE OF COLORADO. J.L.ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK LABELS - PV07 LABEL 6MARKED AT AC DISCONNECTING MEANS. [NEC 690.54] LABEL 5 EQUIPMENT CONTAINING OVERCURRENTDEVICES IN CIRCUITS SUPPLYING POWER TO ABUSBAR OR CONDUCTOR SUPPLIED FROMMULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES.[NEC 705.12(B)(2)(3)(c)] LABEL 3PLACED ADJACENT TO THE BACK-FED BREAKER FROMTHE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR. [NEC 705.12(B)(2)(3)(b)] LABEL 7 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACEDAT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS,PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(D)(2)] LABEL 9SIGN LOCATED ON OR NO MORE THAN 3FTFROM INITIATION DEVICE [NEC 690.56(C)(2)]. LABEL 8FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY:SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROMSERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARECONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [NEC 690.56(C)(1)] LABEL 1 PLACED ON THE MAIN DISCONNECTING MEANS FOR THE PV SYSTEM. [NEC 690.13(B)] LABELING NOTES:1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINEEXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.2. LABELING REQUIREMENTS BASED ON THE 2023 NATIONAL ELECTRIC CODE, OSHA STANDARD19010.145, ANSI Z535.3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [NEC 690.31(D)(2)] LABEL 2 FOR PV DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPENPOSITION. [NEC 690.13(B)] LABEL 11 LABEL TO BE PLACED AT THE MAIN BILLING METER PER XCEL ENERGY. WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD !WARNING THIS EQUIPMENT IS FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC POWER SOURCE TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PHOTOVOLTAIC SYSTEM CONNECTED RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 32.00 240 LABEL 10LABEL TO BE PLACED AT THE AC DISCONNECT.PV AC DISCONNECT EXISTING SUB PANEL (ONLY IF WHERE POINTOF INTERCONNECTION IS MADE) ** ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ELECTRICAL DIAGRAM PAGE. ** JUNCTION BOX MAIN SERVICE PANEL AC DISCONNECT PV COMBINER SUBPANEL - IF USED TO COMBINE PV OUTPUTCIRCUITS OR INVERTER (ONLY IF PVINTERCONNECTIONCONSISTS OF LOAD SIDE BREAKER) (ONLY IF PV INTERCONNECTIONCONSISTS OF LOAD SIDE BREAKER) 1 2 3 4 5 2 3 4 5 1161 9 3 7 7 8 11 10 LABEL 5 PLACED ON EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TOA BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLESOURCES[NEC 705.10] REVIEWED BY SAFEBUILT 04/25/2024 JB M MSP ACINV AC JB J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK CAUTION 333 Ute Ln, Estes Park CO 80517 DIRECTORY: PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.10] PLACARD - PV08 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: MAIN DISTRIBUTION UTILITY DISCONNECT INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH AC DISCONNECT PV ARRAY FR O N T O F H O M E REVIEWED BY SAFEBUILT 04/25/2024 J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK SITE PHOTOS: PHOTOS - PV09 REVIEWED BY SAFEBUILT 04/25/2024 J.L. ELECTRIC & CONTRACTING, LLC 3514 W 29th Ave Apt 4 DENVER, CO 80211 License #EC.0102586 CONTRACTOR INFORMATION: SITE INFORMATION MICHAEL RUPP 333 UTE LN ESTES PARK, CO 80517 AC SYSTEM SIZE: 7.6 KW AC DC SYSTEM SIZE: 7.2 KW DC LAT, 40.3436795 LONG, -105.5284558 (18) HANWHA Q.PEAK DUO BLK ML-G10 400 (1) SOLAREDGE SE7600H-US (240V) (18) SOLAREDGE S440 DRAWN BY: SoloCAD 4/17/2024 TOWN OF ESTES PARK 1. 2. 3.4. ELEVATION DETAIL - PV09.1 1 EAST EXTERIOR WALL (N) UTILITY METER AND MAIN SERVICE PANEL 2 (N) PV AC DISCONNECT 3 (N) PV AC DISCONNECT 4 (N) SOLAREDGE INVERTER SOUTH EXTERIOR SIDE REVIEWED BY SAFEBUILT 04/25/2024 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500V, 168h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400Pa) and wind loads (4000Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. Q.PEAK DUO BLK ML-G10 385-405 ENDURING HIGH PERFORMANCE PR E L I M I N A R Y DETAIL A 16 mm 8.5 mm24.5 mm 1088 mm 1879 mm 4 × Mounting slots (DETAIL A) Frame 1045 mm 996 mm 32 mm 8 × Drainage holes 395.5 mm 4 × Grounding points ø4.5 mm Label •1200 mm •1200 mm RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P O W E R [ % ] YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 155 2 5 200 1 0 98 86 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] Į [%/K] +0.04 ȕ [%/K] −0.27 Ȗ [%/K] −0.34 NMOT [°C] 43±3 [V] 1000 [A] 20 C/TYPE 2 [Pa] 3600/2660 −40°C - +85°C [Pa] 5400/4000 385 390 395 400 405 [W] 385 390 395 400 405 [A] 11.04 11.07 11.10 11.14 11.17 [V] 45.19 45.23 45.27 45.30 45.34 [A] 10.59 10.65 10.71 10.77 10.83 [V] 36.36 36.62 36.88 37.13 37.39 [%] ≥19.6 ≥19.9 ≥20.1 ≥20.4 ≥20.6 [W] 288.8 292.6 296.3 300.1 303.8 [A] 8.90 8.92 8.95 8.97 9.00 [V] 42.62 42.65 42.69 42.72 42.76 [A] 8.35 8.41 8.46 8.51 8.57 [V] 34.59 34.81 35.03 35.25 35.46 Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98% of nominal power dur- ing first year. Thereafter max. 0.5% degradation per year. At least 93.5% of nominal power up to 10 years. At least 86% of nominal power up to 25 years. All data within measurement toler- ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25°C, 1000W/m2). Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q C E L L S Q. P E A K D U O B L K M L - G 1 0 _ 3 8 5 - 4 0 5 _ 2 0 2 1 - 0 2 _ R e v 0 1 _ E N PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Class II Maximum Reverse Current IR Fire Rating based on ANSI/UL 61730 Max. Design Load, Push/Pull Permitted Module Temperature on Continuous DutyMax. Test Load, Push/Pull ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5W/-0W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP I MPP Voltage at MPP VMPP Efficiency1 Ș MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP I MPP Voltage at MPP VMPP 1Measurement tolerances PMPP ±3%; ISC; VOC ±5% at STC: 1000W/m2, 25±2°C, AM 1.5 according to IEC 60904-3 • 2 800W/m², NMOT, spectrum AM 1.5 MECHANICAL SPECIFICATION Format 1879mm × 1045mm × 32mm (including frame) Weight 22.0kg Front Cover 3.2mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 22 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mm Protection class IP67, with bypass diodes Cable 4mm² Solar cable; (+) ≥1200mm, (−) ≥1200mm Connector Stäubli MC4, Hanwha Q CELLS HQC4; IP68 TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature QUALIFICATIONS AND CERTIFICATES IEC 61215:2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. REVIEWED BY SAFEBUILT 04/25/2024 REVIEWED BY SAFEBUILT 04/25/2024 REVIEWED BY SAFEBUILT 04/25/2024 REVIEWED BY SAFEBUILT 04/25/2024 REVIEWED BY SAFEBUILT 04/25/2024 Tech Brief :PTWSPÄLK.YV\UKPUNMVY,]LY`(WWSPJH[PVU The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. UFO Family of Components <UP]LYZHS-HZ[LUPUN6IQLJ[<-6 The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and FDQÀWDZLGHUDQJHRIPRGXOHKHLJKWV he g ore <UP]LYZHS-HZ[L The UFO securely b Rails. It comes asse FDQÀWDZLGHUDQJH :[VWWLY:SLL]L The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp. )6::™ Splice Bonded Structural Splice connects rails with built-in bonding teeth. No tools or hardware needed. )VUKLK([[HJOTLU[Z The bonding bolt attaches and bonds the L-foot to the rail. It is installed with the same socket as the rest of the system. .YV\UKPUN3\N A single Grounding Lug connects an entire row of PV modules to the grounding conductor. )6::™ Splice Bonded Structural Splice il i h b il i :`Z[LT+PHNYHT <3*LY[PÄJH[PVU The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. 0YVU9PKNL0UJ(SSYPNO[ZYLZLY]LK=PZP[^^^PYWH[LU[ZJVTMVYWH[LU[PUMVYTH[PVU=LYZPVU Tech Brief *YVZZ:`Z[LT*VTWH[PIPSP[` -LH[\YL -S\ZO4V\U[ ;PS[4V\U[ .YV\UK4V\U[ XR Rails ((XR100 & XR1000 UFO/Stopper ((( BOSS™ Splice ((N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Compatible with most MLPE manufacturers. Refer to system installation manual. Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. í Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for JURXQGLQJOXJVDQGÀHOGLQVWDOOHGHTXLSPHQWJURXQGFRQGXFWRUV (*& $PLQLPXPRIWZRPLFURLQYHUWHUVPRXQWHGWRWKH same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. .V[V0YVU9PKNLJVT<-6 REVIEWED BY SAFEBUILT 04/25/2024 REVIEWED BY SAFEBUILT 04/25/2024 Cut Sheet © 2022 IronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information. QM-RD-1430-01-M1 Cut Sheet Rev 1.1 21 .43 5/16" Head .22 3.00 #14 DIA .26 .57 .13 1. Self Drilling Screw, #14, Wood Tip 2. Washer, EPDM Backed ITEM NO DESCRIPTION QTY IN KIT 1 Self Drilling Screw, #14, Wood Tip 1 2 Washer, EPDM Backed 1 PART NUMBER DESCRIPTION RD-1430-01-M1 RD Structural Screw Property Value Material 300 Series Stainless Steel Finish Clear Property Value Material 300 Series Stainless Steel Finish Clear QuickMount® RD Structural Screw REVIEWED BY SAFEBUILT 04/25/2024