HomeMy WebLinkAboutPLANS Residential Remodel 155 Davis St 2024-01-25Existing Field Photos
PERMIT #24-EP-00013
Field Copy
Print out legibly & in color and have on site for inspector
REVIEWED BY SAFEbuilt 1/25/24 - PBLAND
All habitable space requires heat
supply and pressure relief.
Fire Block shall be provided in wood framed
walls per locations designated in R302.11
Float all walls - use treated sill
plates (recommended)
Replacement of existing receptacles
outlets shall comply with NEC 406.4 D 1-6
PLANS AND CONSTRUCTION SHALL MEET
THE 2021 IRC, 2023 NEC AND ALL APPLICABLE
MUNICIPAL CODES & ORDINANCES
DO NOT COVER WORK UNTIL IT HAS
BEEN APPROVED BY INSPECTION -
IF YOU HAVE FAILED A ROUGH
INSPECTION YOU MUST HAVE AN
APPROVED REINSPECTION BEFORE
YOU COVER THE WORK UP.
All basement receptacles including
unfinished rooms to be GFCI
Min. one window and well to meet
egress requirements for each sleeping
room
max window sill height 44"
The entire building must be
provided with Smoke Detectors
located as required by code.
CO Detectors are Required wihtin
15 ft. of ALL Bedrooms
Arc fault protection required at
electrical openings
Provide Tamper Resistant
Receptacles
APPROVED by SAFEbuilt;
2021 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
01/25/2024
All permanently installed lighting fixtures,
excluding kitchen appliance lighting fixtures,
shall contain only high-effacy lighting
sources.
Permanently installed lighting fixtures shall be
controlled with a dimmer, an occupant sensor
control or another control that is installed or built
into the fixture.
except bathrooms, hallways, exterior lighting,
lighting designed for safety or security.
SD
SD
SD/CO
within 15' of bdrms