HomeMy WebLinkAboutAsbestos Inspection Report 950 Black Canyon Drive 2020-10-25
Asbestos Inspection
Report
Prepared for:
Craftsman Built Homes and Remodels
Mr. John Tormalehto
1200 Graves Ave, STE 203
Estes Park, CO 80517
Performed At:
950 Black Canyon Drive
Estes Park, CO
October 25, 2020
Project # 6596.20
Inspection and Report by:
Century Environmental Hygiene, LLC
3201 E. Mulberry St, Unit C
Fort Collins, CO 80524
Executive Summary
The property located at 950 Black Canyon Drive, Estes Park, CO was inspected for Asbestos
Containing Materials (ACMs) prior to a remodel. No asbestos was found in any of the materials
sampled. Any materials/areas not mentioned in this report should be assumed ACM until
sampled.
Purpose and Scope
The purpose of the inspection was to conduct an inspection and sampling of any suspect
materials prior to a remodel (see sketches in Appendix D for remodel area).
Methods
The inspection was performed on October 16th, 2020 by Paul Jaeckel a Certified Asbestos
Building Inspector (CDPHE # 830) of Century Environmental Hygiene, LLC (CEH) (ACF
14837). The survey was performed in accordance with protocols described in Regulation #8.
Homogeneous materials were determined by: 1) identifying a list of all materials suspected of
containing asbestos; 2) Classifying these materials as Surfacing, Thermal Systems, or
Miscellaneous material type; 3) Subdividing each material as necessary into Homogeneous
Materials based on color, texture, appearance and other observable factors; 4) identifying the
location(s) of each Homogeneous Material; 5) determining the quantity range of surfacing
materials (quantity range is <1000 SF, 1000-5000 SF, or over 5000 SF). Detailed measurements
are also included if so indicated in the proposal.
Methods for sampling were as described in Regulation 8. A minimum of 1-2 samples for each
Miscellaneous Homogeneous Material is collected. A minimum of 3 samples of each Thermal
System Homogenous Material is collected unless there are less than three linear or square feet of
such material in which case one sample per location is collected. A minimum of 3, 5 or 7
samples of each Surfacing Homogeneous Material were collected depending on the quantity
range identified. Samples are pseudo-randomly located except for surfacing materials which are
either located using a random sampling scheme as recommended in the EPA pink book, using
Table 2. Samples are assigned a unique sample number and submitted to a NVLAP accredited
lab under proper chain of custody for analysis by EPA methods for polarized light microscopy
((EPA-600/M4-82-020, 1982 and EPA-600/R-93/116, July 1993).
The assessment is performed by categorizing materials for friability, current damage, and type of
damage, but this information is only reported for materials that are found to be ACM.
Building Information
According to the Larimer County assessor the house was built in 1983 and is approximately
4,230 sq. ft.
Findings
The drywall, texture, flooring, wallpaper, attic insulation, roofing, and exterior side found in the
remodel area were all sampled, and all came back as Non-ACM. All material locations and sample
results are provided in Table 1 (Appendix A). Sample locations are provided in the sampling
forms (Appendix C).
Sampled by:
Paul Jaeckel, Building Inspector
Attachments:
A. Results data table
B. Lab report
C. Field data sheet
D. Plans or sketches
Disclaimer:
If the owner of the property elects to use certain abatement contractors, CEH reserves the right to decline further
involvement in the project. No evaluations beyond those described in the report have been made and CEH is not
responsible for any hazards or risks, apparent or otherwise, other than those included in this evaluation. As with any
conclusions made based on visual observations and/or random and limited sampling, there is an inherent possibility
that undetected conditions exist, and CEH does not accept liability for any not reasonably ascertainable from the data
or observations made. Sampling can be inherently obtrusive, and CEH does not accept liability for any damage to the
property reasonably occurring during the course of the work in connection with its duties. The only warrantee
expressed or implied is that the work conforms to standard industry practice at the time it was performed. In the
unlikely event a defect in the work is noted, the client has the option to request that the defect be remedied at no
additional cost, or a pro rata deduction in the fee billed. CEH’s maximum liability to any party shall not exceed the
fee for the defective portion of the work. Any reports issued are for the sole use of the client and reliance on it by
others it at their sole risk.
APPENDIX A
Asbestos Sampling Results
950 Black Canyon Drive, Estes Park, CO
Date of Sampling: October 16, 2020
Material Location of Material Sample Number Quantity
Condition Friability Type
Result/ Classification
Pink drywall with joint compound
and tape Throughout house 101620PJ-DTJ01-01 to -02 <5,000 SF Good
Non-Friable
(II)M Non-ACM
Knockdown wall and ceiling
texture Throughout main floor 101620PJ-TXT01-01 to -06 <5,000 SF Good
Non-Friable
(II)S Non-ACM
Orange peel wall and ceiling
texture Throughout basement 101620PJ-TXT02-01 to -03 <1,000 SF Good
Non-Friable
(II)S Non-ACM
Spray on acoustic Main floor ceilings 101620PJ-SOA01-01 to -03 <1,000 SF Good Friable S Non-ACM
Beige 3" tile pattern sheet vinyl
flooring with brown adhesive Bathroom 1 101620PJ-SVF01-01 to -02 <90 SF Good
Non-Friable
(II)M Non-ACM
Yellow 2" tile pattern sheet vinyl
flooring with yellow adhesive Bathroom 2 101620PJ-SVF02-01 to -02 ~90 SF Good
Non-Friable
(II)M Non-ACM
Beige terrazo pattern sheet vinyl
flooring with light colored
adhesive
Work shop/closets 101620PJ-SVF03-01 to -02 ~300 SF Good
Non-Friable
(II)M Non-ACM
Beige reeds wallpaper with clear
adhesive Bathroom 1 101620PJ-WPA01-01 to -02 ~150 SF Good
Non-Friable
(II)M Non-ACM
Dark blue with flowers wallpaper
with clear adhesive Bathroom 2 101620PJ-WPA02-01 to -02 ~200 SF Good
Non-Friable
(II)M Non-ACM
Gray loose attic insulation Attic 101620PJ-AI01-01 to -02 ~2,000 SF Good Friable M Non-ACM
Gray/tan/blue roofing shingles
with brown/black felt Roof 101620PJ-RSG01-01 to -02 ~2,000 SF Good
Non-Friable
(II)M Non-ACM
Gray exterior siding East exterior side 101620PJ-ES01-01 to -02 ~300 SF Good
Non-Friable
(II)M Non-ACM
Table abbreviation explanations:
ACM-I/C = ACM that contains inconsistent results for the group of samples that characterize this material’s asbestos content. The material appeared to the Inspector during the inspection to be the same material type, but results
indicated that it wasn’t exactly the same. According to CDPHE rules, with 1 or more samples indicating asbestos being present, the whole group must be treated as ACM. Unless client performs relevant point counts and/or
additional sampling to further clarify the material’s asbestos content.
ACM = Asbestos-Containing Material. Samples according to AHERA quantities were collected and indicate the material contains over 1% asbestos and is defined by state and/or federal regulations as ACM. In some cases,
inconsistencies may occur (see lab report). For example, four out of five samples collected of this material type may contain asbestos and one did not. In this case, at client’s request, additional sampling might help determine if
the one sample represents a different material application in a sub-part of the area that is non-ACM. An example of when this can happen is when a building is textured, one room is remodeled later and a texture-to-match
existing is used.
ACM-prog = ACM with progressive stop analysis. The material is ACM based on the results received, but not all of the samples were analyzed. Under progressive analysis, samples in a group are analyzed until one sample is
positive to keep within the project sample budget. At client’s request, additional samples can be analyzed to confirm that the material is homogeneous, although additional lab fees apply
Non-ACM indicates that at least the minimum numbers of required samples were analyzed for that type and quantity of material and that all samples indicated 1% or less asbestos so the material is classified by state and federal
agencies as non-ACM. Note that some OSHA requirements still apply if traces of asbestos are present.
P-ACM = Presumed ACM. This material can contain asbestos but was not sampled, and must be treated as ACM in accordance with state and/or federal regulations
OSHA-ACM. This material is considered ACM by OSHA but not by EPA/CDPHE because EPA and CDPHE allow joint compound used as filler at seams, edges, and screw holes etc. in drywall is not ACM if the composite of
the drywall and joint compound is 1% or less asbestos. Note that only a limited effort was made to determine if the material is used only at seams etc. and there is the possibility in parts of the building that a skim coat does
it
Asbestos Sampling Results
950 Black Canyon Drive, Estes Park, CO
Date of Sampling: October 16, 2020
M: Miscellaneous
S: Surfacing
T: TSI
Low % ACM. This material either contained a trace of asbestos, in which case it is ACM unless a Point Count (PC) analysis is performed and it is determined to be 1% or less asbestos by PC, or the material contained a low
percentage of asbestos e.g. 1-2% and a PC could still be performed and interpreted the same way. The client should consider requesting PC analysis of some or all samples to determine if the material may qualify as non-ACM.
(PC): If this term appears as a suffix, it indicates that Point Count analysis was employed and the Point Count results replaced the PLM result when the results were interpreted.
exist.
APPENDIX B
12421 W. 49TH AVENUE, UNIT #6
WHEAT RIDGE, CO 80033 (303) 463-8270
BULK ASBESTOS TEST REPORT
PAGE 1 OF 7
CLIENT:ANALYSIS DATE:10-20-20
CENTURY ENVIRONMENTAL HYGIENE REPORTING DATE:10-22-20
3201 E. MULBERRY STREET, UNIT C RECEIPT DATE:10-19-20
FORT COLLINS, CO 80524 CLIENT JOB NO.:6596.20
CLIENT PROJECT:950 BLACK CANYON DR., ESTES PARK, CO
DCMSL PROJECT:CEH1272
PERCENTAGE COMPOSITION BY VISUAL ESTIMATE
TOTAL
DCMSL SAMPLE SAMPLE TOTAL PERCENTAGE
SAMPLE NUMBER DATE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED
NUMBER (C) (C)DESCRIPTION OF SAMPLE TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS
-1 101620PJ-DTJ01-01 10-16-20 A.WHITE PAINT 1.0%ND 0.0 100.0 100.0
B.WHITE DRYWALL MUD 5.0%ND 0.0 100.0 100.0
C.TAN/WHITE FIBROUS 30.0%ND 100.0 0.0 100.0
D.PINK DRYWALL 64.0%ND ____________1.0 99.0 100.0
ND
-2 101620PJ-DTJ01-02 10-16-20 A.YELLOW/WHITE PAINT 0.5%ND 0.0 100.0 100.0
B.WHITE DRYWALL MUD 4.0%ND 0.0 100.0 100.0
C.TAN FIBROUS 25.0%ND 100.0 0.0 100.0
D.PINK DRYWALL 70.5%ND ____________1.0 99.0 100.0
ND
-3 101620PJ-TXT01-01 10-16-20 A.WHITE PAINT 12.0%ND 0.0 100.0 100.0
B.WHITE TEXTURE 88.0%ND ____________0.0 100.0 100.0
ND
-4 101620PJ-TXT01-02 10-16-20 A.WHITE PAINT 8.0%ND 0.0 100.0 100.0
B.WHITE TEXTURE 92.0%ND ____________0.0 100.0 100.0
ND
-5 101620PJ-TXT01-03 10-16-20 A.PINK DRYWALL 12.0%ND 0.0 100.0 100.0
B.WHITE PAINT 20.0%ND 0.0 100.0 100.0
C.WHITE TEXTURE 24.0%ND 0.0 100.0 100.0
D.TAN FIBROUS 44.0%ND ____________100.0 0.0 100.0
ND
-6 101620PJ-TXT01-04 10-16-20 A.PINK DRYWALL 20.0%ND 0.0 100.0 100.0
B.WHITE PAINT 22.0%ND 0.0 100.0 100.0
C.TAN FIBROUS 25.0%ND 100.0 0.0 100.0
D.WHITE TEXTURE 33.0%ND ____________0.0 100.0 100.0
ND
12421 W. 49TH AVENUE, UNIT #6
WHEAT RIDGE, CO 80033 (303) 463-8270
BULK ASBESTOS TEST REPORT
PAGE 2 OF 7
CLIENT:ANALYSIS DATE:10-20-20
CENTURY ENVIRONMENTAL HYGIENE REPORTING DATE:10-22-20
3201 E. MULBERRY STREET, UNIT C RECEIPT DATE:10-19-20
FORT COLLINS, CO 80524 CLIENT JOB NO.:6596.20
CLIENT PROJECT:950 BLACK CANYON DR., ESTES PARK, CO
DCMSL PROJECT:CEH1272
PERCENTAGE COMPOSITION BY VISUAL ESTIMATE
TOTAL
DCMSL SAMPLE SAMPLE TOTAL PERCENTAGE
SAMPLE NUMBER DATE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED
NUMBER (C) (C)DESCRIPTION OF SAMPLE TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS
-7 101620PJ-TXT01-05 10-16-20 A.PINK DRYWALL 6.0%ND 0.0 100.0 100.0
B.WHITE PAINT 20.0%ND 0.0 100.0 100.0
C.WHITE TEXTURE 30.0%ND 0.0 100.0 100.0
D.TAN FIBROUS 44.0%ND ____________100.0 0.0 100.0
ND
-8 101620PJ-TXT01-06 10-16-20 A.WHITE PAINT 10.0%ND 0.0 100.0 100.0
B.WHITE TEXTURE 90.0%ND ____________0.0 100.0 100.0
ND
-9 101620PJ-TXT02-01 10-16-20 A.WHITE DRYWALL 3.0%ND 0.0 100.0 100.0
B.WHITE PAINT 25.0%ND 0.0 100.0 100.0
C.WHITE TEXTURE 27.0%ND 0.0 100.0 100.0
D.TAN FIBROUS 45.0%ND ____________100.0 0.0 100.0
ND
-10 101620PJ-TXT02-02 10-16-20 A.YELLOW PAINT 5.0%ND 0.0 100.0 100.0
B.TAN FIBROUS 40.0%ND 100.0 0.0 100.0
C.WHITE TEXTURE 55.0%ND ____________0.0 100.0 100.0
ND
-11 101620PJ-TXT02-03 10-16-20 A.WHITE PAINT 12.0%ND 0.0 100.0 100.0
B.WHITE TEXTURE 15.0%ND 0.0 100.0 100.0
C.PINK DRYWALL 25.0%ND 0.5 99.5 100.0
D.TAN FIBROUS 48.0%ND ____________100.0 0.0 100.0
ND
-12 101620PJ-SOA01-01 10-16-20 A.WHITE FOAMY CEILING TEXTURE 100.0%ND ____________1.0 99.0 100.0
ND
12421 W. 49TH AVENUE, UNIT #6
WHEAT RIDGE, CO 80033 (303) 463-8270
BULK ASBESTOS TEST REPORT
PAGE 3 OF 7
CLIENT:ANALYSIS DATE:10-20-20
CENTURY ENVIRONMENTAL HYGIENE REPORTING DATE:10-22-20
3201 E. MULBERRY STREET, UNIT C RECEIPT DATE:10-19-20
FORT COLLINS, CO 80524 CLIENT JOB NO.:6596.20
CLIENT PROJECT:950 BLACK CANYON DR., ESTES PARK, CO
DCMSL PROJECT:CEH1272
PERCENTAGE COMPOSITION BY VISUAL ESTIMATE
TOTAL
DCMSL SAMPLE SAMPLE TOTAL PERCENTAGE
SAMPLE NUMBER DATE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED
NUMBER (C) (C)DESCRIPTION OF SAMPLE TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS
-13 101620PJ-SOA01-02 10-16-20 A.WHITE FOAMY CEILING TEXTURE 100.0%ND ____________1.0 99.0 100.0
ND
-14 101620PJ-SOA01-03 10-16-20 A.WHITE FOAMY CEILING TEXTURE 100.0%ND ____________1.0 99.0 100.0
ND
-15 101620PJ-SVF01-01 10-16-20 A.TAN MASTIC 10.0%ND 5.0 95.0 100.0
B.GREY FIBROUS RESIN 40.0%ND 50.0 50.0 100.0
C.YELLOW/GREY RESINOUS TILE 50.0%ND ____________0.0 100.0 100.0
ND
-16 101620PJ-SVF01-02 10-16-20 A.TAN MASTIC 7.0%ND 3.0 97.0 100.0
B.GREY FIBROUS RESIN 40.0%ND 50.0 50.0 100.0
C.YELLOW/GREY RESINOUS TILE 53.0%ND ____________0.0 100.0 100.0
ND
-17 101620PJ-SVF02-01 10-16-20 A.TAN MASTIC 0.5%ND 0.0 100.0 100.0
B.WHITE MASTIC 0.5%ND 0.0 100.0 100.0
C.GREY FIBROUS RESIN 42.0%ND 60.0 40.0 100.0
D.YELLOW/GREY RESINOUS TILE 57.0%ND ____________0.0 100.0 100.0
ND
-18 101620PJ-SVF02-02 10-16-20 A.TAN MASTIC 0.5%ND 0.0 100.0 100.0
B.WHITE MASTIC 0.5%ND 0.0 100.0 100.0
C.GREY FIBROUS RESIN 40.0%ND 60.0 40.0 100.0
D.YELLOW/GREY RESINOUS TILE 59.0%ND ____________0.0 100.0 100.0
ND
-19 101620PJ-SVF03-01 10-16-20 A.WHITE MASTIC 0.5%ND 0.0 100.0 100.0
B.GREY FIBROUS RESIN 30.0%ND 60.0 40.0 100.0
C.MULTICOLORED RESINOUS TILE 69.5%ND ____________0.0 100.0 100.0
ND
12421 W. 49TH AVENUE, UNIT #6
WHEAT RIDGE, CO 80033 (303) 463-8270
BULK ASBESTOS TEST REPORT
PAGE 4 OF 7
CLIENT:ANALYSIS DATE:10-20-20
CENTURY ENVIRONMENTAL HYGIENE REPORTING DATE:10-22-20
3201 E. MULBERRY STREET, UNIT C RECEIPT DATE:10-19-20
FORT COLLINS, CO 80524 CLIENT JOB NO.:6596.20
CLIENT PROJECT:950 BLACK CANYON DR., ESTES PARK, CO
DCMSL PROJECT:CEH1272
PERCENTAGE COMPOSITION BY VISUAL ESTIMATE
TOTAL
DCMSL SAMPLE SAMPLE TOTAL PERCENTAGE
SAMPLE NUMBER DATE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED
NUMBER (C) (C)DESCRIPTION OF SAMPLE TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS
-20 101620PJ-SVF03-02 10-16-20 A.WHITE MASTIC 2.0%ND 0.0 100.0 100.0
B.GREY FIBROUS RESIN 30.0%ND 60.0 40.0 100.0
C.MULTICOLORED RESINOUS TILE 68.0%ND ____________0.0 100.0 100.0
ND
-21 101620PJ-WPA01-01 10-16-20 A.CLEAR MASTIC 1.0%ND 0.0 100.0 100.0
B.WHITE PAINT 1.0%ND 0.0 100.0 100.0
C.WHITE PLASTER 3.0%ND 0.0 100.0 100.0
D.WHITE/TAN WALLPAPER 95.0%ND ____________80.0 20.0 100.0
ND
-22 101620PJ-WPA01-02 10-16-20 A.CLEAR MASTIC 1.0%ND 0.0 100.0 100.0
B.TAN FIBROUS 1.0%ND 100.0 0.0 100.0
C.WHITE PAINT 2.0%ND 0.0 100.0 100.0
D.WHITE PLASTER 3.0%ND 0.0 100.0 100.0
E.WHITE/TAN WALLPAPER 93.0%ND ____________80.0 20.0 100.0
ND
-23 101620PJ-WPA02-01 10-16-20 A.CLEAR MASTIC 2.0%ND 0.0 100.0 100.0
B.WHITE PAINT 2.0%ND 0.0 100.0 100.0
C.TAN FIBROUS 35.0%ND 100.0 0.0 100.0
D.BLUE/YELLOW WALLPAPER 61.0%ND ____________65.0 35.0 100.0
ND
-24 101620PJ-WPA02-02 10-16-20 A.CLEAR MASTIC 2.0%ND 0.0 100.0 100.0
B.WHITE PAINT 2.0%ND 0.0 100.0 100.0
C.TAN FIBROUS 35.0%ND 100.0 0.0 100.0
D.MULTICOLORED WALLPAPER 61.0%ND ____________65.0 35.0 100.0
ND
12421 W. 49TH AVENUE, UNIT #6
WHEAT RIDGE, CO 80033 (303) 463-8270
BULK ASBESTOS TEST REPORT
PAGE 5 OF 7
CLIENT:ANALYSIS DATE:10-20-20
CENTURY ENVIRONMENTAL HYGIENE REPORTING DATE:10-22-20
3201 E. MULBERRY STREET, UNIT C RECEIPT DATE:10-19-20
FORT COLLINS, CO 80524 CLIENT JOB NO.:6596.20
CLIENT PROJECT:950 BLACK CANYON DR., ESTES PARK, CO
DCMSL PROJECT:CEH1272
PERCENTAGE COMPOSITION BY VISUAL ESTIMATE
TOTAL
DCMSL SAMPLE SAMPLE TOTAL PERCENTAGE
SAMPLE NUMBER DATE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED
NUMBER (C) (C)DESCRIPTION OF SAMPLE TYPE RANGE %IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS
-25 101620PJ-AI01-01 10-16-20 A.GREY FIBROUS 100.0%ND ____________100.0 0.0 100.0
ND
-26 101620PJ-AI01-02 10-16-20 A.GREY FIBROUS 100.0%ND ____________100.0 0.0 100.0
ND
-27 101620PJ-RSG01-01 10-16-20 A.BLACK TAR 10.0%ND 0.0 100.0 100.0
B.MULTICOLORED ROCK 15.0%ND 0.0 100.0 100.0
C.BLACK FIBROUS TAR 30.0%ND 20.0 80.0 100.0
D.BROWN FIBROUS TAR 45.0%ND ____________65.0 35.0 100.0
ND
-28 101620PJ-RSG01-02 10-16-20 A.MULTICOLORED ROCK 15.0%ND 0.0 100.0 100.0
B.BLACK TAR 20.0%ND 0.0 100.0 100.0
C.BROWN FIBROUS TAR 25.0%ND 65.0 35.0 100.0
D.BLACK FIBROUS TAR 40.0%ND ____________20.0 80.0 100.0
ND
-29 101620PJ-ES01-01 10-16-20 A.GREY PAINT 14.0%ND 0.0 100.0 100.0
B.GREY FIBROUS RESINOUS PLASTER 86.0%ND ____________30.0 70.0 100.0
ND
-30 101620PJ-ES01-02 10-16-20 A.GREY PAINT 8.0%ND 0.0 100.0 100.0
B.GREY FIBROUS RESINOUS PLASTER 92.0%ND ____________30.0 70.0 100.0
ND
FOR CALCULATION PURPOSES, TRACE (TR) IS ASSUMED TO BE 0.5%.
(C) INFORMATION PROVIDED BY CLIENT (I) INSEPARABLE LAYERS ND - NONE DETECTED
12421 W. 49TH AVENUE, UNIT #6
WHEAT RIDGE, CO 80033 (303) 463-8270
BULK ASBESTOS TEST REPORT
PAGE 6 OF 7
CLIENT:ANALYSIS DATE:10-20-20
CENTURY ENVIRONMENTAL HYGIENE REPORTING DATE:10-22-20
3201 E. MULBERRY STREET, UNIT C RECEIPT DATE:10-19-20
FORT COLLINS, CO 80524 CLIENT JOB NO.:6596.20
CLIENT PROJECT:950 BLACK CANYON DR., ESTES PARK, CO
DCMSL PROJECT:CEH1272
THE SAMPLE(S) WAS/WERE RECEIVED IN ACCEPTABLE CONDITION. THIS TEST REPORT RELATES ONLY TO THE ITEMS TESTED. THE RESULTS OF THIS REPORT APPLY TO THE SAMPLE(S) RECEIVED
FROM THE CLIENT AND THE VALIDITY OF THE RESULTS ARE DEPENDENT ON ANY INFORMATION SUPPLIED BY THE CLIENT. THIS REPORT MAY NOT BE REPRODUCED EXCEPT IN FULL WITHOUT
THE WRITTEN APPROVAL OF THE LABORATORY.
ALL INFORMATION PROVIDED BY CLIENTS, INCLUDING SAMPLE RESULTS, IS CONSIDERED PROPRIETARY AND CONFIDENTIAL. CLIENT RESULTS AND OTHER INFORMATION WILL NOT BE
RELEASED TO ANYONE BUT THE CLIENT EXCEPT BY CLIENT REQUEST. WHEN THE LABORATORY IS REQUIRED BY LAW OR AUTHORIZED BY CONTRACTUAL ARRANGEMENTS TO RELEASE
CONFIDENTIAL INFORMATION, THE CLIENT OR INDIVIDUAL CONCERNED SHALL, UNLESS PROHIBITED BY LAW, BE NOTIFIED OF THE INFORMATION PROVIDED.
APPENDIX C
APPENDIX D