Loading...
HomeMy WebLinkAboutPLANS 23-504 225 Park Ln, walkway to grease trap 2023-09-20NORTH ELEVATION SCALE 1/4" = 1'-0" END WALKWAY JOIST REMOVABLE LADDER CANTILEVERED EDGE BEAMS PER PLAN EXISTING GRADE EXISTING GRADE EXISTING PLATFORM FRAMING TO REMAIN GREASE TRAP WEST ELEVATION SCALE 1/4" = 1'-0" GUARDRAIL PER PLAN REMOVABLE LADDER CANTILEVERED EDGE BEAMS PER PLAN EDGE OF ROOF 2x4 RAILS @ TOP, MIDDLE & BTM. MAX 27" OPENING BETWEEN RAILS AND 4" FROM TOP OF WALKWAY FLOOR ATTACH MIDDLE & BTM RAILS W/ SIMPSON A34 CLIP, EACH SIDE C T L T H O M P S O N PR O J E C T L O C A T I O N : CL I E N T : co n t a c t : DATE: PROJECT # SCALE: PER PLAN DESIGN/CHK: DRAWN: RE V I S I O N / I S S U E DA T E NO . 1 TH E S E D R A W I N G S A N D A C C O M P A N Y I N G SP E C I F I C A T I O N S , A S I N S T R U M E N T S O F S E R V I C E AR E T H E E X C L U S I V E P R O P E R T Y O F T H E EN G I N E E R A N D T H E I R U S E A N D P U B L I C A T I O N SH A L L B E R E S T R I C T E D T O T H E O R I G I N A L S I T E F O R WH I C H T H E Y W E R E P R E P A R E D . R E U S E , RE P R O D U C T I O N O R P U B L I C A T I O N B Y A N Y ME T H O D I N W H O L E O R I N P A R T I S P R O H I B I T E D EX C E P T B Y W R I T T E N P E R M I S S I O N F R O M T H E EN G I N E E R . T I T L E T O T H E S E P L A N S A N D SP E C I F I C A T I O N S S H A L L R E M A I N W I T H T H E EN G I N E E R W I T H O U T P R E J U D I C E , A N D V I S U A L CO N T A C T W I T H T H E M S H A L L C O N S T I T U T E P R I M A FA C I E E V I D E N C E O F A C C E P T A N C E O F T H E S E RE S T R I C T I O N S . CO P Y R I G H T CT L | T H O M P S O N , I N C O R P O R A T E D AL L R I G H T S R E S E R V E D . CT L I T H O M P S O N I N C O R P O R A T E D 40 0 N o r t h L i n k L a n e Fo r t C o l l i n s , C O 8 0 5 2 4 P: 9 7 0 - 2 0 6 - 9 4 5 5 F: 9 7 0 - 2 0 6 - 9 4 4 1 ww w . c t l t . c o m 73 5 4 S O U T H P I E R C E S T R E E T LI T T L E T O N , C O L O R A D O MI K E M C C O Y 30 3 - 5 1 4 - 6 7 4 2 DTH DTH FC10726.000 04/04/2023 CL A I R E ' S R E S T A U R A N T M A I N T E N A N C E W A L K W A Y ES T E S P A R K , C O L O R A D O BL U E P E A K S R O O F I N G SHEET NUMBER: 1OF SHEETS 2 3 22 5 P A R K L A N E UP D A T E D E S I G N C R I T E R I A 04 / 0 5 / 2 0 2 3 PL A N R E V I E W C O M M E N T S 09 / 2 7 / 2 0 2 3 MA I N T E N A N C E WA L K W A Y P L A N S1MAINTENANCE WALKWAY FRAMING PLAN SCALE 1/4" = 1'-0" EXISTING PLATFORM TO REMAIN. MIN 30" WIDTH AROUND ENTIRE PLATFORM HAS BEEN CONFIRMED BY CONTRACTOR EX I S T I N G 1 1 7 8" T J I 3 6 0 RA F T E R S @ 2 4 " O . C . TO R E M A I N (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 (2 ) 2 x 6 HSS2.5x0.125" COLUMN @ 4' O.C. ALTERNATE POSTS SO ONLY ONE POINT LOAD IS ADDED TO EACH EXISTING RAFTER CANTILEVER WALKWAY BEAMS UP TO 1' FOR LADDER BRACING 2x 6 J O I S T S @ 1 6 " O . C . 1'-4 " EXISTING RAFTER PACK OUT TJI WEB PER MANUFACTURER SPECIFICATIONS. MIN 16" SECTION ATTACH STEEL PLATE TO RAFTER W/ (4) 14"Øx3" SDWS SCREWS ⅊6"x6"x14" A36 STEEL. WELD TO COLUMN W/ 1 4" FILLET WELD EACH SIDE NEW HSS2.5x0.125" ROUND COLUMN. ALTERNATE RAFTERS THAT COLUMNS ARE ATTACHED TO NEW BEAM PER PLAN. ATTACH TO COLUMN W/ CCOQ COLUMN CAP W/ 1 4" FILLET WELD TO TOP OF COLUMN NEW PLATFORM JOISTS PER PLAN A NEW COLUMN TO RAFTER 2. Limitations: It is the contractors/owners responsibility to verify and coordinate all dimensions prior to construction. 1. Framing: Misc: All framing shall be in accordance with the provisions of 2015 IBC. All connections or members not shown are per code or the general contractor/owner. All manufactured wood products shall be installed per the manufacturers specifications. Refer to the code for additional requirements. All wood shall be pressure treated. Provide solid blocking to transmit all point loads continuous to the foundation as necessary. GENERAL NOTES Soils: Assumed per 2015 IBC Table 1806.2 and to be verified at Open-hole by CTL I THOMPSON. Assumed allowable bearing pressure: Max. 1,500 psf ATTACH COLUMN ON ALTERNATING RAFTERS PER NOTES ABOVE 4x4 DF#2 POST @ 48" O.C., ATTACH TO DOUBLE JOIST W/ (2) 1 4"Ø BOLTS AT EACH POST 1 1 NOTE : THE LADDER IS TO BE A DETACHABLE LADDER THAT LEANS AGAINST THE CANTILEVERED BEAM. THE LADDER WILL BE DETACHABLE AND NOT A PERMANENT FIXTURE TO NOT ALLOW PUBLIC ACCESS TO THE PLATFORM NOTE : ALL WOOD TO BE PRESSURE TREATED LUMBER 2' - 6 " 2" SQUARE PLATE WASHER AT FRONT AND BACK OF BOLT, TYP 31 2" 1" , T Y P 2x4 DF#2 TOP RAIL. ATTACH TO TOP OF POST W/ (2) 412" LAG SCREWS, TYP EACH RAIL NOTE : ROOF HATCH BEHIND GUARDRAIL REMOVED FOR CLARITY 3'-0" 2 2 2 2 Guard along this walkway must be minimum 42" above walking surface, openings in guard cannot exceed 21" Max 21" opening Reviewed by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 10/03/2023