HomeMy WebLinkAboutPLANS PV System 1755 Dekker Circle 2023-06-2306/19/2023 1104 Industrial Blvd. Albion, MI 49224 (913) 304-2381 GLS&E Project #: 230530-A Next Energy Solar 8925 Pieper Rd., Building A, Unit D Wellington, CO 80549 (970) 900-2003 RE: Structural Roof Evaluation for the Dale Residence: 1755 Dekker Cir., Estes Park, CO 80517 To whom it may concern: Per your request, I have reviewed the existing structure for the additional loading from the proposed PV system that is to be installed by Next Energy Solar at the above address. This review includes evaluation of the existing structure’s ability to handle the additional gravitational loads associated with the new system. Evaluation assumptions: 1. The structure is in conformance with the building codes at time of construction. 2. Bracing required by original designer/manufacturer is installed as required. 3. The conditions of the overall roof structure are consistent with those represented in the initial site inspection photos and as provided by Next Energy Solar in the Site Survey package. Evaluation Criteria: Code: IRC 2015 Edition; ASCE 7-10 Wind speed: 175 mph (3-sec gust) Risk Category: II Exposure Category: C Elevation: 7875 ft Ground Snow Load: 65 psf Mean Roof Height: 20 ft Roof Pitch: 18 degrees Construction Type: Rafters Rafter Size, Spacing: 2x4 rafters @ 24” O.C. Roofing Material: Asphalt Shingles Number of Panels: 6 (Roof #1), 21 (Roof #2), 22 (Roof #3), & 13 (Roof #4) Panel Area: 127.98 ft2 (Roof #1), 447.93 ft2 (Roof #2), 469.26 ft2 (Roof #3), & 277.29 ft2 (Roof #4) 06/19/2023 REVIEWED BY SAFEBUILT 06/23/2023 06/19/2023 1104 Industrial Blvd. Albion, MI 49224 (913) 304-2381 The addition of the PV system will result in design loads less than 105% of the loads the structure is currently designed for. The live load can be omitted in the areas where the PV system will be installed as there will no longer be access. In my professional opinion the existing roof is adequate for carrying the additional loads associated with the proposed solar array system with the following conditions: 1. Construction shall conform to all pertinent state and local building codes and ordinances. 2. It is recommended that roof attachments alternate between rafters to distribute loads. 3. The engineer-of-record shall be consulted if conditions other than those specified in this letter are encountered. 4. Attachments shall be Everest K2 Systems Splice Foot XL with M5 x 60mm DIN 571 hex head lag screws with minimum 2” embedment installed per manufacturer’s specifications with a maximum spacing of 48” unless permitted in writing by the engineer. 5. All components shall be installed per manufacturer’s specifications. The solar array will be mounted parallel to the existing roof no more than 6” above the roof surface. Any change in wind loads to the structure from the panel addition are assumed to be negligible. Regards, Dunley M. Stults, PE* Great Lakes Solar & Engineering, PLLC 1104 Industrial Blvd. Albion, MI 49224 Colorado License No. 58994 06/19/2023 REVIEWED BY SAFEBUILT 06/23/2023 06/19/2023 1104 Industrial Blvd. Albion, MI 49224 (913) 304-2381 Roof Dead Loads (ASCE Table C3-1): Asphalt Shingles 2 PSF 5/8” Plywood Sheathing 2 PSF Roof Framing 4 PSF Solar Panel Array 2.25 PSF Dead Load Without Panels 8.0 PSF Dead Load With Panels 10.25 PSF Roof Live Load: Existing Roof Live Load 20 PSF Roof Live Load with Solar Panels 0 PSF Roof Snow Load (ASCE 7-16): Ground Snow Load (pg) 65 PSF Exposure Factor (Ce) 0.9 Thermal Factor (Ct) 1.1 Importance Factor (I) 1.0 Flat Roof Snow Load (Pf) 45.05 PSF Slippery Surface Slope Factor (Cs) 0.90 Reduced Roof Snow Load (Slippery Surface) 40.55 PSF Load Combinations (ASCE 7-16 Section 2.4.1): Without Panels With Panels DL + Lr X X DL + SL 8.0 psf DL + 45.05 psf SL 8.0 psf DL + point loads from panel DL and SL 06/19/2023 REVIEWED BY SAFEBUILT 06/23/2023 06/19/2023 1104 Industrial Blvd. Albion, MI 49224 (913) 304-2381 Wind Calculations Roof #1 (ASCE 7-16) – Conservatively assume Zone 2n for entire array: GCp Zone 2n (127.98 sq.ft) -1.4 Figure 30.3 (2A-I) Gcpi 0.18 Table 26.13-1 Kh 0.90 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Ke 0.80 Table 26.9-1 qh 45.28 PSF Equation 26.10-1 Design Pressures Equation 30.3-1 Pressure (Zone 2n) -71.54 PSF 9156 LB Connection Check – Roof #1: Shear Capacity 215 LBS Manufacturer’s Tables Uplift Capacity 505 LBS Manufacturer’s Tables # of Connections Provided 20 Min. Connections Req’d 19 Factor of Safety 1.05 Wind Calculations Roof #2 (ASCE 7-16) – Conservatively assume Zone 2n for entire array: GCp Zone 2n (447.93 sq.ft) -1.0 Figure 30.3 (2A-I) Gcpi 0.18 Table 26.13-1 Kh 0.90 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Ke 0.80 Table 26.9-1 qh 45.28 PSF Equation 26.10-1 Design Pressures Equation 30.3-1 Pressure (Zone 2n) -53.43 PSF 23935 LB Connection Check – Roof #2: Shear Capacity 215 LBS Manufacturer’s Tables Uplift Capacity 505 LBS Manufacturer’s Tables # of Connections Provided 83 Min. Connections Req’d 48 Factor of Safety 1.72 06/19/2023 REVIEWED BY SAFEBUILT 06/23/2023 06/19/2023 1104 Industrial Blvd. Albion, MI 49224 (913) 304-2381 Wind Calculations Roof #3 (ASCE 7-16) – Conservatively assume Zone 2n for entire array: GCp Zone 2n (469.26 sq.ft) -1.0 Figure 30.3 (2A-I) Gcpi 0.18 Table 26.13-1 Kh 0.90 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Ke 0.80 Table 26.9-1 qh 45.28 PSF Equation 26.10-1 Design Pressures Equation 30.3-1 Pressure (Zone 2n) -53.43 PSF 25075 LB Connection Check – Roof #3: Shear Capacity 215 LBS Manufacturer’s Tables Uplift Capacity 505 LBS Manufacturer’s Tables # of Connections Provided 85 Min. Connections Req’d 50 Factor of Safety 1.70 Wind Calculations Roof #4 (ASCE 7-16) – Conservatively assume Zone 2n for entire array: GCp Zone 2n (277.29 sq.ft) -1.0 Figure 30.3 (2A-I) Gcpi 0.18 Table 26.13-1 Kh 0.90 Table 26.10-1 Kht 1 Equation 26.8-1 Kd 0.85 Table 26.6-1 Ke 0.80 Table 26.9-1 qh 45.28 PSF Equation 26.10-1 Design Pressures Equation 30.3-1 Pressure (Zone 2n) -53.43 PSF 14816 LB Connection Check – Roof #4: Shear Capacity 215 LBS Manufacturer’s Tables Uplift Capacity 505 LBS Manufacturer’s Tables # of Connections Provided 30 Min. Connections Req’d 30 Factor of Safety 1.00 06/19/2023 REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING SCOPE:22.320 KW DC ROOF MOUNT SOLAR PV SYSTEM WITH 62 SILFAB SOLAR SIL-360 NX 360W PV MODULES WITH 31 AP SYSTEM DS3-L MICROINVERTERS COVER SHEET AUTHORITIES HAVING JURISDICTION: BUILDING: ESTES PARK ZONING: ESTES PARK UTILITY: ESTES PARK UTILITIES PV-1 PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX CODE REFERENCES PROJECT ADDRESS 1755 DEKKER CIRCLE, ESTES PARK, CO 80517 OWNER:NATHAN DALE CONTRACTOR: DESIGNER:ESR HOUSE PHOTO PHOTOVOLTAIC ROOF MOUNT SYSTEM 62 MODULES-ROOF MOUNTED - 22.320 kW DC, 23.808 kW AC 1755 DEKKER CIRCLE, ESTES PARK, CO 80517 PV-1 COVER SHEET PV-2 PLOT PLAN WITH ROOF PLAN PV-3 ROOF PLAN & MODULES PV-4 ELECTRICAL PLAN PV-5 ATTACHMENT DETAIL PV-6 ELECTRICAL LINE DIAGRAM PV-7 WIRING CALCULATION PV-8 LABELS PV-9 PLACARD PV-10 MICROINVERTER CHART PV-11+ EQUIPMENT SPECIFICATIONS PARCEL ID:0546593 PROJECT TO COMPLY WITH THE FOLLOWING: 2020 NATIONAL ELECTRICAL CODE (NEC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) ARRAY LOCATIONS NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 PROJECT SITE 1.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. 2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2020. 3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. 4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. 5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24. 7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. 10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 11.ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 12.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)] 13.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 14.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. 15.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41. 16.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 17.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)] 18.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 19.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 20.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 21.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. 22.MODULE DOES NOT EXCEED THE SLOPE OF ROOF B 06/19/2023 SEAL LIMITED TO STRUCTURAL COMPONENTS SAFEbuilt APPROVED Subject to inspection and compliance to all relevant Adopted Building and Municipal codes. Changes in Plans MUST be approved. D.GRAHAM 06/23/2023 I-CODES 2015 23-ep-00275 PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION INSTALLATION INSTRUCTIONS AND MANUALS MUST BE ON JOB FOR THE INSPECTOR AT THE TIME OF INSPECTION FOR ALL EQUIPMENT. APPROVAL IS FOR STRUCTURAL REVIEW ONLY. ELECTRICAL INSPECTIONS TO BE PER THE STATE OF COLORADO. 164'-85" 29 4 ' - 4 " 15 6 ' - 8 8 " 23 2 ' - 5 " M S P U M M S D 1 PLOT PLAN WITH ROOF PLAN SCALE: 1"=30'-0"PV-2 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING PROJECT DESCRIPTION: 62 x SILFAB SOLAR SIL-360 NX 360W PV MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES DC SYSTEM SIZE: 22.320kW DC AC SYSTEM SIZE: 23.808kW AC PLOT PLAN WITH ROOF PLAN PV-2 EQUIPMENT SUMMARY 62 SILFAB SOLAR SIL-360 NX 360W MONO MODULES 31 AP SYSTEM DS3-L MICROINVERTERS (E) FENCE ROOF #4 (6) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM ROOF #1 (11) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM ROOF ARRAY AREA #1:- 217.14 SQ FT. ROOF ARRAY AREA #2:- 414.54 SQ FT. ROOF ARRAY AREA #3:- 355.32 SQ FT. ROOF ARRAY AREA #4:- 118.44 SQ FT. ROOF ARRAY AREA #5:- 118.44 SQ FT. E X I S T I N G D R I V E W A Y 2 - S T O R Y H O U S E (E) TREES PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E (E) MAIN SERVICE PANEL PR O P E R T Y L I N E DE K K E R C I R C L E ROOF #2 (21) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM ROOF #3 (18) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM (E) UTILITY METER/MAIN COMBO (ON POLE) PE A K V I E W D R ROOF #5 (6) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM B 06/19/2023 SEAL LIMITED TO STRUCTURAL COMPONENTS REVIEWED BY SAFEBUILT 06/23/2023 2 0 ' - 8 " 25'- 3 " 6'-2 " 4 ' - 0 " M S P U M M S D 1 0 ' - 7 " 3 ' - 0 " 3'-0 " 20'- 8 " 3'-0 " 21'- 1 " 3 ' - 2 " 2 5 ' - 3 " MODULE TYPE, DIMENSIONS & WEIGHT 1 ROOF PLAN & MODULES PV-3 SCALE: 3/32" = 1'-0" ROOF PLAN & MODULES REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING NUMBER OF MODULES = 62 MODULES MODULE TYPE = SILFAB SOLAR SIL-360 NX 360W MONO MODULES MODULE WEIGHT = 44 LBS / 20.0KG. MODULE DIMENSIONS = 72.13" x 39.4" = 19.74 SF SILFAB SOLAR SIL-360 NX 360W MODULES 72 . 1 3 " 39.4" PV-3 MSP - MAIN SERVICE PANEL - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - TRUSS LEGEND ROOF DESCRIPTION ROOF TYPE COMP. SHINGLE ROOF ROOF PITCH AZIMUTH TRUSS SIZE TRUSS SPACING #1 18°232°2"X4"24" #2 18°142°2"X4"24" #3 18°232°2"X4"24" #4 18°142°2"X4"24" #5 18°322°2"X4"24" ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 11 217.14 607.28 36 #2 21 414.54 770.83 54 #3 18 355.32 804.47 44 #4 6 118.44 421.47 28 #5 6 118.44 421.47 28 TOTAL 62 1223.88 4691.09 26 UM - UTILITY METER (195) EVEREST K2 SPLICE FOOT XL ATTACMENTS (N) UNIRAC SOLARMOUNT RAIL 36" F I R E S E T B A C K 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K R O O F # 1 P I T C H - 1 8 ° A Z I M . - 2 3 2 ° 36" F I R E S E T B A C K 3 6 " F I R E S E T B A C K ROO F # 2 PITC H - 18 ° AZIM . - 142 ° 3 6 " F I R E S E T B A C K ROO F # 4 PITC H - 18 ° AZIM . - 142 ° ROOF #4 (6) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM ROOF #1 (11) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM (E) MAIN SERVICE PANEL ROOF #2 (21) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM ROOF #3 (18) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM (E) UTILITY METER/MAIN COMBO (ON POLE) MSD - MAIN SERVICE DISCONNECT 36 " F I R E S E T B A C K ROOF #5 (6) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH AP SYSTEM ROO F # 5 PITC H - 18 ° AZIM . - 322 ° B 36" F I R E S E T B A C K 3 6 " F I R E S E T B A C K 36" F I R E S E T B A C K ROO F # 3 PITC H - 18 ° AZIM . - 232 ° 06/19/2023 SEAL LIMITED TO STRUCTURAL COMPONENTS REVIEWED BY SAFEBUILT 06/23/2023 C P A C D M S P U M M S D JB JB JB JB JB 1 ELECTRICAL PLAN PV-4 SCALE: 3/32" = 1'-0" ELECTRICAL PLAN REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING PV-4 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 62 SILFAB SOLAR SIL-360 NX 360W MICRO INVERTERS 31 AP SYSTEM DS3-L MICROINVERTERS JUNCTION BOXES 5 JUNCTION BOXES RAILS 45 UNIRAC SOLARMOUNT RAIL SPLICE 24 SPLICE KIT MODULE CLAMPS 88 MID MODULE CLAMPS END CLAMPS 72 END CLAMPS / STOPPER SLEEVE ATTACHMENTS 195 EVEREST K2 SPLICE FOOT XL ATTACMENTS - JUNCTION BOXJB UM MSP - UTILITY METER - MAIN SERVICE PANEL - CONDUIT ACD - AC DISCONNECT - COMBINER PANELCP - DS3-L MICROINVERTER LEGEND (N) CONDUIT RUN (N) JUNCTION BOX (TYP.) (31) AP SYSTEM DS3-L MICROINVERTERS UNDER EVERY 2ND MODULE CIRCUIT #2 (10 MODULES) CIRCUIT #3 (10 MODULES) CIRCUIT #1 (10 MODULES) (E) UTILITY METER/MAIN COMBO (ON POLE) (N) FUSED AC DISCONNECT (N) COMBINER PANEL (E) MAIN SERVICE PANEL CIRCUIT #4 (8 MODULES) CIRCUIT #5 (8 MODULES) CIRCUIT #5 CIRCUIT #6 CIRCUIT #1 CIRCUIT #2 CIRCUIT #3 CIRCUIT #4 CIRCUIT LEGENDS CIRCUIT #7 CIRCUIT #7 (8 MODULES) CIRCUIT #6 (8 MODULES) MSD - MAIN SERVICE DISCONNECT B REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING ATTACHMENT DETAIL PV-52ATTACHMENT DETAIL (ENLARGED VIEW) PV-5 1 ATTACHMENT DETAIL (SIDE VIEW) PV-5 SCALE: N.T.S. SCALE: N.T.S. SEE (2/PV-5) FOR ENLARGED VIEW PV MODULE (E) COMP. SHINGLE ROOF2"X4" TRUSS @ 24 " O.C. PV MODULE GROUNDING END/MID CLAMP (E) COMP. SHINGLE ROOF 2"X4" TRUSS @ 24" O.C. M5 X 60MM DIN 571, METRIC, HEX HEAD LAG SCREW BOLTS, A2 STAINLESS STEEL WITH MIN. 2" PENETRATION INTO SUPPORT EVEREST K2 SYSTEMS SPLICE FOOT XL ATTACHMENTS 6 " UNIRAC SOLARMOUNT RAIL 06/19/2023 SEAL LIMITED TO STRUCTURAL COMPONENTS REVIEWED BY SAFEBUILT 06/23/2023 LOAD LINE G 125A Fuses PV FUSE AC DISCONNECT 240V, 1ɸ, 3W 200A RATED NEMA 3R BRANCH TERMINATOR (ET-TERM) -+ 2 -+ 1 -+-+-+ BRANCH #5 -+ 2 -+ 1 -+-+-+ BRANCH #6 L1 L2 G G L1 L2 L1 L2 20A/2P 20A/2P COMBINER PANEL, 200A, 120/240V, 3W, NEMA 3R, UL LISTED +- +-JUNCTION BOX, 600V, NEMA 3R, UL LISTED 20A/2P === === 21 BRANCH #7 8765 -+-+-+-+-++- === -+ 2 -+ 1 -+-+-+ BRANCH #3 -+ 2 -+ 1 -+-+-+ BRANCH #4 +- +- 10987 === === AP SYSTEM DS3-L MICROINVERTERS 20A/2P 20A/2P L1 L2 L1 L2 1 2 3 L1 L2 G VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10' OF INTERCONNECTION -+ 2 -+ 1 -+-+-+ BRANCH #2 +- 10987 === (62) SILFAB SOLAR SIL-360 NX 360W MONO MODULES 20A/2P L1 L2 L1 L2 4 E G N NL2L1 M EXISTING GROUNDING ELECTRODE SYSTEM TO EARTH REF. NEC 250.52, 250.53(A) LOAD SIDE INTERCONNECTION AT MAIN SERVICE PANEL PER ART. 705.12 GEC G N (E) MAIN BREAKER TO HOUSE 240V, 200A/2P (E) MAIN SERVICE PANEL, 200A RATED, 240V (E) MAIN SERVICE DISCONNECT,200A RATED, 240V (E) MAIN BREAKER TO HOUSE 240V, 200A/2P L1 L2 N G BI-DIRECTIONAL UTILITY METER 120/240V 1ɸ, 3-W 8765 8765 8765 L1 L2 -+ 2 -+ 1 -+-+-+ BRANCH #1 +- 10987 === 20A/2P G LOAD SIDE CONNECTION 2020 NEC 705.12(B)(1)(a) / 705.12(B)(1)(b) REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-6 SCALE: NTS PV-6 1 2 3 4 QTY CONDUCTOR INFORMATION CONDUIT TYPE CONDUIT SIZE CU#12AWG -PV WIRE/USE-2 N/A N/A(1)CU#6AWG -BARE COPPER IN FREE AIR (14)CU#12AWG -THHN (L1,L2)NMB IN ATTIC 3/4"(1)CU#12AWG -THHN GND (2)THHN (L1,L2)EMT, LFNC, NMB OR LFMC(1)THHN GND (2)THHN (L1,L2)EMT, LFNC, NMB OR LFMC CU#6AWG - DC SYSTEM SIZE: 22.320 kW DC AC SYSTEM SIZE: 23.808 kW AC (62) SILFAB SOLAR SIL-360 NX 360W MONO MODULES WITH (31) AP SYSTEM DS3-L MICROINVERTERS (3) BRANCH CIRCUITS OF 10 MODULES & 5 MICROINVERTERS AND (4) BRANCH CIRCUITS OF 8 MODULES & 4 MICROINVERTERS ARE CONNECTED IN PARALLEL 1-1/4" 1-1/4" NOTE WIRE SCHEDULE CALLOUT (E) IS EXISTING SYSTEM (14) CU#1AWG - CU#1AWG -NOTE: ALL CONDUCTOR SIZES CAN BE SHOWN AS IN THE TABLE OR CODE APPROVED EQUIVALENT #12/2 ROMEX IN ATTIC (1)THHN GNDCU#6AWG - INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES: 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH GROUNDING & GENERAL NOTES: 1. A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [NEC 690.47(C)(3)] 2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 5. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BE INSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS. 8. ALL NEW SERVICE INSTALLATIONS AND REPLACEMENTS REQUIRE A SURGE-PROTECTIVE DEVICE (SPD) IN ACCORDANCE WITH [NEC 230.67]. THE SPD SHALL BE TYPE 1 OR TYPE 2 AND IS REQUIRED TO BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO. RACKING NOTES: 1. BOND EVERY OTHER RAIL WITH #6 BARE COPPER ELECTRICAL INSPECTIONS AND PLAN REVIEWS (IF REQUIRED) PER THE STATE OF COLORADO. REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING WIRING CALCULATIONS PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 AMBIENT TEMPERATURE SPECS RECORD LOW TEMP -27° AMBIENT TEMP (HIGH TEMP 2%)24° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.28%/°C SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #SILFAB SOLAR SIL-360 NX 360W MODULE VMP 37.11V IMP 9.70A VOC 45.40V ISC 10.20A TEMP. COEFF. VOC -0.28%/°C MODULE DIMENSION 72.13"L x 39.4"W x 1.5"D (In Inch) PV-7 ELECTRICAL NOTES 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.WHERE SIZES OF SOLADECK, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THE SOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. INVERTER SPECIFICATIONS MANUFACTURER / MODEL #AP SYSTEM DS3-L MICROINVERTER NOMINAL AC POWER 0.768 KW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 3.20A ELECTRICAL INSPECTIONS AND PLAN REVIEWS (IF REQUIRED) PER THE STATE OF COLORADO. REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING LABELS PV-8 TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! ELECTRICAL SHOCK HAZARD LABEL LOCATION: AC DISCONNECT COMBINER MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT CODE REF: NEC 690.13(B) LABEL- 1: !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: UTILITY METER MAIN SERVICE PANEL SUBPANEL CODE REF: NEC 705.12(D)(3) & NEC 690.59 LABEL- 2: TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL WARNING! LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL MAIN SERVICE DISCONNECT COMBINER CODE REF: NEC 110.27(C) & OSHA 1910.145 (f) (7) LABEL- 3: LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) SUBPANEL (ONLY IF SOLAR IS BACK-FED) CODE REF: NEC 690.13 (F), NEC 705.12(B) (3-4) & NEC 690.59 LABEL- 4: CAUTION! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEED LABEL LOCATION: MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED) SUBPANEL (ONLY IF SOLAR IS BACK-FED) CODE REF: NEC 705.12(B)(2)(c) LABEL- 5: SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT CODE REF: IFC 605.11.3.1(1) & NEC 690.56(C)(1)(a) LABEL- 6: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: AC DISCONNECT CODE REF: NEC 690.13(B) LABEL- 7: LABEL- 8: LABEL LOCATION: MAIN SERVICE PANEL SUBPANEL AC DISCONNECT CODE REF: NEC 690.13(B) PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLATGE 240 V WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE ! RATED AC OUTPUT CURRENT 99.20 A LABEL LOCATION: UTILITY METER LABEL- 14: LABEL LOCATION: AC DISCONNECT CODE REF: NEC 690.13(B) LABEL- 13: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PV SYSTEM DISCONNECT REVIEWED BY SAFEBUILT 06/23/2023 C P A C D M S P U M M S D JB JB JB JB JB REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING PLACARD 1755 DEKKER CIRCLE, ESTES PARK, CO 80517 PV-9 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(A)(B), [NEC 705.10]) NOTE: PLACARD MAYNOT BE DISPLAYED UNLESS REQUIRED BY UTILITY COMPANY LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535. 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] (N) PV ARRAY MULTIPLE SOURCES OF POWER CAUTION: (N) JUNCTION BOX (TYP.) (E) UTILITY METER/MAIN COMBO (ON POLE) (N) AC DISCONNECT (N) COMBINER PANEL (E) MAIN SERVICE PANEL REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING MICRO INVERTER CHART MICRO INVERTER CHART 1-10 2 3 4 11-20 21-30 31-40 41-50 51-60 5 61-70 6 7 8 9 10 1 PV-10 REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING EQUIPMENT SPECIFICATION PV-11 REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING EQUIPMENT SPECIFICATION PV-12 REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING EQUIPMENT SPECIFICATION PV-13 REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING EQUIPMENT SPECIFICATION PV-14 REVIEWED BY SAFEBUILT 06/23/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER NA T H A N D A L E RE S I D E N C E 17 5 5 DE K K E R C I R C L E , ES T E S P A R K , CO 8 0 5 1 7 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS DATE:04/18/2023 DRAWN BY ESR NEXT ENERGY SOLAR 8925 PIEPER RD BUILDING A UNIT D WELLINGTON, CO 80549 (970)900-2003 A04/20/2023REVISION B06/08/2023CITY COMMENTS C06/09/2023PANELS RATING EQUIPMENT SPECIFICATION PV-15 REVIEWED BY SAFEBUILT 06/23/2023