HomeMy WebLinkAboutPLANS Patio 915 Moraine Ave 2021-05-204.12.21
4.12.21
4.12.21
4.12.21
4.12.21
4.12.21
"This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek
and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek
assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or
damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this
report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of
the tested material, product or service must first be approved in writing by Intertek. The observations and test results
in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or
service is or has ever been under an Intertek certification program."
1
REPORT NUMBER: 102083832MID-001d
ORIGINAL ISSUE DATE: April 28, 2015
REVISED DATE: NA
EVALUATION CENTER
Intertek
8431 Murphy Drive
Middleton, WI 53562
Rendered To:
Serge Ferrari
Zone Industrielle BP 54
38352 La Tour Du Pin Cedex
38110 LA TOUR DU PIN
France
Catherine Merillon
catherine.merillon@sergeferrari.com
PRODUCT EVALUATED: Precontraint 502
EVALUATION PROPERTY: NFPA 701-10, METHOD 1
STANDARD METHODS OF FIRE TESTS FOR FLAME
PROPAGATION OF TEXTILES AND FILMS
Report of Testing Precontraint 502 for compliance with the applicable
requirements of the following criteria: NFPA 701-10, METHOD 1 Standard
Methods of Fire Tests for Flame Propagation of Textiles and Films
TE
S
T
R
E
P
O
R
T
Serge Ferrari April 28, 2015
Report No. 102083832MID-001d Page 2 of 8
1 Table of Contents
1 TABLE OF CONTENTS ..................................................................................................... 2
2 INTRODUCTION ................................................................................................................ 3
3 TEST SAMPLES ................................................................................................................ 3
3.1. SAMPLE SELECTION ................................................................................................. 3
3.2. SAMPLE AND ASSEMBLY DESCRIPTION................................................................. 3
4 TESTING AND EVALUATION METHODS ......................................................................... 3
4.1. TEST STANDARD ....................................................................................................... 3
4.2. DEVIATIONS FROM THE STANDARD METHOD ....................................................... 4
5 TESTING AND EVALUATION RESULTS .......................................................................... 4
5.1. RESULTS AND OBSERVATIONS ............................................................................... 4
6 CONCLUSION ................................................................................................................... 5
7 REVISION SUMMARY ....................................................................................................... 5
Serge Ferrari April 28, 2015
Report No. 102083832MID-001d Page 3 of 8
2 Introduction
Intertek has conducted testing for Serge Ferrari on Precontraint 502 to assess the propagation
of flame beyond the area exposed to the ignition source. Testing was conducted in accordance
with NFPA 701-10, Method 1 - Standard Methods of Fire Tests for Flame Propagation of
Textiles and Films. This evaluation began April 27, 2015 and ended April 27, 2015.
3 Test Samples
3.1. SAMPLE SELECTION
Samples were submitted to Intertek directly from the client. Samples were not independently
selected for testing. Samples were received at the Evaluation Center on April 21, 2015 in good
condition.
3.2. SAMPLE AND ASSEMBLY DESCRIPTION
Sample Name: Precontraint 502
Sample Description: Polyester yarns coated with PVC flame retardant on both sides and
varnished.
Weight: 590 g/m² ± 5%, Thickness: 0.47mm ± 10%, Polyester 1100 dtex: 28% - PVC flame
retardant 72%
The test specimen identified as Precontraint 502 was cut into 5.9 in. x 15.75 in. samples by
Intertek. The samples were weighed in grams before testing. Ten specimens were numbered,
weighed and conditioned for at least 30 min. at 220± 5°F (105± 3°C) before testing. The
specimens were removed from the oven one at a time and tested within 2 minutes.
4 Testing and Evaluation Methods
4.1. TEST STANDARD
The top edge of the specimen was attached to a pin bar so that the specimen was centered and
the long dimension of the specimen is in the vertical position with 0.75” binder clips attached to
the specimen at each bottom corner to hold it taut. A specified test flame is applied to the
bottom center of the specimen for 45 seconds and then removed with eye observation
continued.
The average weight loss of ten specimens was not greater than forty percent (40%). The
percent weight loss of any individual specimen did not exceed the mean percent weight loss
value. The average floor flame of ten specimens was not greater than 2 seconds.
Serge Ferrari April 28, 2015
Report No. 102083832MID-001d Page 4 of 8
4.2. Deviations from the Standard Method
No deviations.
5 Testing and Evaluation Results
5.1. RESULTS AND OBSERVATIONS
Environmental Conditions: 72.8⁰F and 48% R.H.
Sample
No. Wt. Before (g)
Wt. After test
(g)
Percent Wt.
Loss
AfterFlame
Floor
Flame
1 36.33 35.83 1.38 0.0 0.0
2 36.14 35.09 2.91 0.0 0.0
3 36.46 35.04 3.89 0.0 0.0
4 36.86 35.81 2.85 0.0 0.0
5 36.97 35.26 4.63 0.0 3.0
6 35.75 34.87 2.46 0.0 0.0
7 35.68 34.42 3.53 0.0 0.0
8 35.69 35.18 1.43 0.0 0.0
9 36.53 35.48 2.87 0.0 0.0
10 36.15 35.46 1.91 0.0 0.0
Average 36.26 35.24 2.79 0.0 0.3
Any fragments that fell to the floor did not burn more than 2 seconds. The average weight loss
of the ten samples was less than 40%. The mean percent weight loss value plus three standard
deviations of the percent weight loss is 5.77.
Based on this information it is concluded the specimen passes the test criteria.
Serge Ferrari April 28, 2015
Report No. 102083832MID-001d Page 5 of 8
6 Conclusion
Intertek has conducted testing for Serge Ferrari on Precontraint 502 to assess the propagation
of flame beyond the area exposed to the ignition source. Testing was conducted in accordance
with NFPA 701-10 Standard Methods of Fire Tests for Flame Propagation of Textiles and Films-
Method 1.
The sample PASSED the testing criteria for NFPA 701-10, Method 1 - Standard Methods of Fire
Tests for Flame Propagation of Textiles and Films.
INTERTEK
Reported by: _____________________
Tolu Bamikunle
Lab Technician III, Verification Center
Reviewed by: _____________________
Sandy Osborne
Lab Technician II, Verification Center
7 Revision Summary
DATE SUMMARY
April 28, 2015 Original Report