HomeMy WebLinkAboutPLANS Remodel 585 Audubon St B 2021-05-20Per contractor this is drawn incorrectly. No such wall exists at this location. APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 05/20/2021 Reviewed by SAFEbuilt 05/20/2021 Although drawings show a change from existing to proposed, per contractor there will be no change to this 3/4 bath. See letter. General Notes: -Min (1) emergency escape and rescue opening req’d per bedroom -Glazing to be tempered per R308 -Min (1) programmable thermostat req’d -Smoke alarm req’d in each sleeping room -Smoke/CO alarm req’d w/in 15’ vicinity of bedroom exterior. -Fireblock/Draftstop all chases and penetrations 2015 IECC -75% OF LAMPS SHALL BE HIGH EFFICIENCY -ALL DUCT WORK LOCATED OUSIDE THE THERMAL ENVELOPE SHALL BE TESTED FOR LEAKAGE Reviewed by SAFEbuilt 05/20/2021 Reviewed by SAFEbuilt 05/20/2021 Reviewed by SAFEbuilt 05/20/2021 R312.1.3 Opening limitations. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a sphere 4 inches (102 mm) in diameter. Reviewed by SAFEbuilt 05/20/2021 PO Box 2373, Estes Park, CO 80517 Phone: 970-586-6551 Fax: 970-586-5148 To whom it may concern: I am writing this letter to address the plan review comments associated with: 1.I believe the following drawings are the same location but don’t want to assume anything: Storage vs new master bath? RESPONSE- You are correct. The new bath will be located where the exisng storage area is 2.The following area is not in compliance with Section R307: Date: 5/12/2021 Jurisdiction: Estes Park Project: Addition Site Address: 585 B Audobon St. Permit#: 21-EP-00184 Contact Person: Jared Kingswood Reviewed by SAFEbuilt 05/20/2021 RESPONSE- We will not be doing any work on this bathroom and it is not part of the permit 3.This does not meet code Code Section reads: R312.1.3 Opening limitations. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a sphere 4 inches (102 mm) in diameter. Exceptions: 1. The triangular openings at the open side of stair, formed by the riser, tread and bottom rail of a guard, shall not allow passage of a sphere 6 inches (153 mm) in diameter. 2. Guards on the open side of stairs shall not have openings that allow passage of a sphere 43/8 inches (111 mm) in diameter. RESPONSE- This should read “Spacing between opening s to be less than 4” “ It seems like these can just be redlined on the plans instead of having to redraw everything. Please let me know if you need anything else. Jared Kingswood (970) 214-8007 jared@homesbykingswood.com Reviewed by SAFEbuilt 05/20/2021