HomeMy WebLinkAboutPLANS Remodel 456 Skyline Dr 2021-02-26EX I S T I N G UP DO W N MAIN LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0"N MAIN LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0"N SHOWER DIMENSIONS SCALE: 1/4" = 1'-0" MAIN LEVEL FLOOR COVERINGS SCALE: 1/16" = 1'-0" GENERAL NOTES 1) ALL DIMENSIONS ARE FROM FACE OF STRUCTURE TO FACE OF STRUCTURE, UNLESS NOTED OTHERWISE. 2) THIS IS A REMODEL / ADDITION TO AN EXISTING STRUCTURE AND DIMENSIONS MAY NEED TO BE ADJUSTED IN FIELD. 3) ALL DIMENSIONS MARKED WITH ± ARE APPROXIMATE. 4) INSPECT AND VERIFY EXISTING CONDITIONS. NOTIFY G.C. OF ANY DISCREPANCIES OR QUESTIONS. 5) ALL WORK SHALL COMPLY WITH LOCAL CODES AND REGULATIONS. 6) MAINTAIN A CLEAN AND SAFE WORK-SITE AT ALL TIMES. CLEAN UP CONSTRUCTION DEBRIS ON A REGULAR BASIS. 7) INSTALL 2x8 BLOCKING IN LOCATIONS TO BE COORDINATED WITH G.C. AND OWNER. 8) ASBESTOS TEST PERFORMED BY EARTH ENERGY ENVIRONMENT ON 12/20 INDICATED NO PRESENCE OF HAZARDOUS MATERIALS. EQUAL EQUAL 3'-8"1'-4" 5'-0"2'-10" 7'-10" EQUAL EQUAL 11'-9" ± 30" x 18" FIXED (2) 36" x 48" CASEMENT EGRESS 2' - 8 " 6' - 1 " 11'-1 1/2" ±5'-6" 1'-0" APPROX 17'-4" OVERALL 1'- 0 " AP P R O X 2 6 ' - 4 " O V E R A L L 70" x 47" FIXED 35" x 47" CASEMENT 70 " x 4 7 " F I X E D EDGE OF FIREPLACE 5'-6"9"9"3'-10" ± 24" x 18" FIXED 5' - 6 " UP REBUILD EXISTING STAIRS TO MEET CODE (6) RISERS MAX 7-3/4" EACH (5) TREADS MIN 10" EACH 4'- 0 " 2'- 0 " GAME ROOM 11'-9" x 14'-5" ENTRY 5'-6" x 8'-7" HALLWAY 16'-8" x 5'-6" BENCH AND CUBBIES BY OWNER SHOWER 5'-0" x 8'-5"POWDER EXISTING DINING EXISTING KITCHEN EXISTING SOAKING TUB RAISED LEDGE 24" x 16" NICHE 9" EXISTING VENT EXISTING WATER SHUT-OFF TO REMAIN 2'-11 1/2" 5' - 2 " 10 " ± BENCH 30" WIDE FROSTED GLASS SHOWER DOOR 2' - 8 " EX I S T I N G G.C. INSTALL MIRROR PROVIDED BY CLIENT RECESS NEW FLOOR IN SHOWER ROOM TO ALLOW FOR SLOPED SHOWER PAN AND PROPER DRAINAGE EXISTING ELECTRICAL PANEL RE-INSULATE EAST AND WEST EXTERIOR WALLS IN WORK AREA RE-INSULATE EAST AND WEST EXTERIOR WALLS IN WORK AREA GARAGE EXISTING NEW STEPS RE-USE EXISTING STONE COUNTERTOPLIVING ROOM EXISTING INSULATE BETWEEN CEILING AND FLOOR BELOW BATHROOM AND CLOSET. PATCH & PAINT CEILING IN AREAS WHERE GYP BD WAS REMOVED FOR WORK BEING DONE ON UPPER LEVEL. LIVING ROOM EXISTING 1' - 4 " 1' - 4 " 1' - 4 " 4'- 0 " 2' - 2 " ± 2' - 0 " 6" VERIFY DIMENSION WITH TUB CHOSEN 1'-4" TOP OF BENCH 18"-20" ABOVE FLOOR BOTTOM OF NICHE 36" ABOVE FLOOR TOP OF DECK VERIFY HEIGHT WITH TUB CHOSEN TOP OF LEDGE VERIFY HEIGHT WITH TILE CHOSEN EXISTING 5'-0 " 3 0 ° INSTALL NEW WOOD CAP OVER EXPOSED TOP OF FOUNDATION TILE FLOOR L.V.T. FLOOR EXISTING CABINETS TO REMAIN NEW COUNTERTOP AND BACKSPLASH 3" T Y P I C A L EXISTING COLOR KEY NEW DEMOLITION BY OWNER NEW VANITY RE-INSTALL EXISTING TOILET A1 02 / 17 / 2021 SA R A H & J O H N M I L B U R N R E S I D E N C E R E M O D E L 45 6 S K Y L I N E D R I V E - E S T E S P A R K , C O 8 0 5 1 7 OF 3 SHEET NUMBER ISSUE DATE REVISIONS MAIN LEVEL FLOOR PLANS SHEET TITLE - - - CLIENT APPROVEDFINAL SET TO BE USED FOR:ENGINEERING, ESTIMATING, PERMITTING, AND CONSTRUCTION SHOWER LINER TEST REQUIRED. IF THERE IS NO THRESHOLD A TEMPORARY THRESHOLD TO BE BUILT NOT LESS THAN 2" HIGH. TYPICAL FOR ALL SHOWER TESTS. TEMPERED GLASS ALL SHOWER DOORS TO OPEN OUTWARD, MUST HAVE 22" OF CLEARANCE WITH DOOR OPEN OUT. WINDOWS CLOSER THAN 24" FROM FLOOR TO SILL AND MORE THAN 72" FROM OPENING TO GROUND REQIRE FALL PROTECTION FOR THE WINDOW MINIMUM U FACTOR FOR REPLACEMENT WINDOWS TO BE .32 OR LESS 4 OR MORE STAIRS REQUIRE HANDRAIL SAFEbuilt APPROVED Subject to inspection and compliance to all relevant Adopted Building and Municipal codes. Changes in Plans MUST be approved. D.GRAHAM 02/26/2021 PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION I-CODES 2015 21-EP-00064 (2) 2x8 HEADER (2) K, (1) J EACH SIDE (2) 2x8 HEADER (2) K, (1) J EACH SIDE (2 ) 2 x 1 2 HE A D E R (3 ) K , ( 2 ) J EA C H S I D E (2) 1-3/4" x 11-7/8" LVL HEADER (4) K, (3) J EACH SIDE UPPER LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0"N UPPER LEVEL FLOOR COVERINGS SCALE: 1/16" = 1'-0" MAIN LEVEL STRUCTURAL SCALE: 1/8" = 1'-0" (2) 2x12 HEADER (2) K, (2) J EACH SIDE UPPER LEVEL STRUCTURAL SCALE: 1/8" = 1'-0" STRUCTURAL NOTES Building Code Information 2015 IRC Risk Category II Roof Dead Load = 15 psf Floor Dead Load = 10 psf Floor Live Load = 40 psf Ground snow load = 65 psf (at 7500' elev) Roof snow load = 50 psf Vult = 175 mph, Exp C Seismic Design Category B All lumber shall be Hem Fir #2 or better. All LVL material shall be 1.9E minimum grade. Van Horn Engineering Frank Roberts - PE# 39508 Phone 970.586.9388 frank@vanhornengineering.com OPTIONAL SHOWER SCALE: 1/4" = 1'-0" 24" x 24" BENCH 12" x 12" NICHE 30" WIDE FROSTED GLASS SHOWER DOOR 5' - 0 " 2'-8"3'-10"3'-2" (2) 2x8 HEADER (1) K, (1) J EACH SIDE (2 ) 2 x 8 HE A D E R (2 ) K , ( 1 ) J EA C H S I D E RECESS NEW FLOOR IN SHOWER ROOM TO ALLOW FOR SLOPED SHOWER PAN AND PROPER DRAINAGE RAISED FLOOR FRAMING MIN 2x8 AT 16" OC SUPPORTED ON LEDGER ON SLAB REBUILD EXISTING STAIRS TO MEET CODE (6) RISERS MAX 7-3/4" EACH (5) TREADS MIN 10" EACH (2) SIDE STRINGERS, (2) MID STRINGERS 5' - 0 " 5' - 1 0 " 10 ' - 1 0 " 2'-10"4'-2"6'-7" ± 6" 6" 6'-2"4'-4"3'-1" ± 4'-4"2'-8"2'-8"3'-11" ± CLOSET ORGANIZATION SYSTEM BY OWNER 1'- 1 1 " 3' - 7 " TILE FLOOR WITH ELECTRIC HEAT BENEATH EXTENT OF NEW FLOORING OR REPAIR OF EXISTING T.B.D. BATHROOM AND CLOSET 13'-7" x 10'-10" 24" x 16" NICHE 24" x 24" BENCH 30" WIDE FROSTED GLASS SHOWER DOOR INSULATE FLOORS IN BATHROOM AND CLOSET MASTER BEDROOM 13'-7" x 14'-11" DECK EXISTING PAINT NO PAINT DOWN LAUNDRY EXISTING BATHROOM EXISTING BEDROOM EXISTING BEDROOM EXISTING HALLWAY EXISTING OPTIONAL NEW CABINET ABOVE TOILET - T.B.D. G.C. TO INSTALL CLIENT SUPPLIED VANITY, MED CAB, AND MIRROR 18 " x 3 6 " C A S E M E N T 2'-6" CLR 2'-2" GENERAL NOTES 1) ALL DIMENSIONS ARE FROM FACE OF STRUCTURE TO FACE OF STRUCTURE, UNLESS NOTED OTHERWISE. 2) THIS IS A REMODEL / ADDITION TO AN EXISTING STRUCTURE AND DIMENSIONS MAY NEED TO BE ADJUSTED IN FIELD. 3) ALL DIMENSIONS MARKED WITH ± ARE APPROXIMATE. 4) INSPECT AND VERIFY EXISTING CONDITIONS. NOTIFY G.C. OF ANY DISCREPANCIES OR QUESTIONS. 5) ALL WORK SHALL COMPLY WITH LOCAL CODES AND REGULATIONS. 6) MAINTAIN A CLEAN AND SAFE WORK-SITE AT ALL TIMES. CLEAN UP CONSTRUCTION DEBRIS ON A REGULAR BASIS. 7) INSTALL 2x8 BLOCKING IN LOCATIONS TO BE COORDINATED WITH G.C. AND OWNER. 8) ASBESTOS TEST PERFORMED BY EARTH ENERGY ENVIRONMENT ON 12/20 INDICATED NO PRESENCE OF HAZARDOUS MATERIALS. EXISTING COLOR KEY NEW DEMOLITION BY OWNER 36" WIDE GLASS PANEL BARN DOOR REFER TO DOCUMENTS FOR MORE INFORMATION A2 02 / 17 / 2021 SA R A H & J O H N M I L B U R N R E S I D E N C E R E M O D E L 45 6 S K Y L I N E D R I V E - E S T E S P A R K , C O 8 0 5 1 7 OF 3 SHEET NUMBER ISSUE DATE REVISIONS UPPER LEVEL FLOOR PLANS AND ALL STRUCTURAL SHEET TITLE - - - CLIENT APPROVEDFINAL SET TO BE USED FOR:ENGINEERING, ESTIMATING, PERMITTING, AND CONSTRUCTION TEMPERED GLASS REVIEWED BY SAFEBUILT 02/26/2021 WOOD IN CONTACT WITH CONCRETE IS TO TREATED OR OTHER APPROVED MATERIAL ALL SHOWER DOORS TO OPEN OUTWARD, MUST HAVE 22" OF CLEARANCE WITH DOOR OPEN OUT. SHOWER LINER TEST REQUIRED. IF THERE IS NO THRESHOLD A TEMPORARY THRESHOLD TO BE BUILT NOT LESS THAN 2" HIGH. TYPICAL FOR ALL SHOWER TESTS. MAIN LEVEL DEMOLITION PLAN SCALE: 1/8" = 1'-0"N UPPER LEVEL DEMOLITION PLAN SCALE: 1/8" = 1'-0"N MAIN LEVEL ELECTRICAL LAYOUT SCALE: 1/8" = 1'-0"NMAIN LEVEL LIGHTING LAYOUT SCALE: 1/8" = 1'-0"N UPPER LEVEL ELECTRICAL LAYOUT SCALE: 1/8" = 1'-0"NUPPER LEVEL LIGHTING LAYOUT SCALE: 1/8" = 1'-0"N ELECTRICAL SYMBOLS 1) ALL FIXTURES ARE TO BE SELECTED BY OWNER. 2) LOCATIONS SHOWN ARE TO BE USED ONLY FOR REFERENCE. 3) ELECTRICIAN TO VERIFY ALL CODES AND REQUIREMENTS ARE FOLLOWED. 4) COORDINATE WITH OWNER ON RELOCATION OF EXISTING FIXTURES WHERE NECESSARY. ELECTRICAL NOTES 2' - 7 ½" ± 5' - 1 " 5' - 0 " 2' - 3 " ± 5'-1½"11'-0"3'-5½" ± 3'-0" EQUAL EQUAL 10'-2½" ±7'-0"2'-4½" ± 11'-5½" ± 1½" 4½" 9' - 7 ½" ± RE-USE EXISTING STONE COUNTERTOP REMOVE EXISTING STEPS AND BARN DOOR EXISTING CABINETS TO REMAIN NEW COUNTERTOP AND BACKSPLASH 3' - 2 " REBUILD EXISTING STAIRS TO MEET CODE EXISTING ELECTRICAL PANEL DUPLEX OUTLET PHONE/DATA OUTLET WITH LED NITELITE OUTLET WITH U.S.B. PORTS SMOKE DETECTOR C/O AND SMOKE ELECTRIC BASEBOARD TOE-KICK HEATER SWITCH RECESSED CAN OR PUCK RECESSED WET LOCATION DECORATIVE SURFACE FAN & LIGHT WITH HEAT WALL MOUNT VANITY LIGHT CEILING FAN (NO LIGHT) THERMOSTAT HEAT UNDER FLOOR TILE CAR CHARGER HEAT UNDER FLOOR TILE EXISTING TO REMAIN CHARGING AREA WITH OUTLETS AND (2) USB PORTS AT 48" AFF COORDINATE WITH OWNER EXISTING TO REMAIN EXISTING TO REMAIN TO EXISTING TO EXISTING LIGHT TO EXISTING FAN TO EXISTING GENERAL NOTES 1) ALL DIMENSIONS ARE FROM FACE OF STRUCTURE TO FACE OF STRUCTURE, UNLESS NOTED OTHERWISE. 2) THIS IS A REMODEL / ADDITION TO AN EXISTING STRUCTURE AND DIMENSIONS MAY NEED TO BE ADJUSTED IN FIELD. 3) ALL DIMENSIONS MARKED WITH ± ARE APPROXIMATE. 4) INSPECT AND VERIFY EXISTING CONDITIONS. NOTIFY G.C. OF ANY DISCREPANCIES OR QUESTIONS. 5) ALL WORK SHALL COMPLY WITH LOCAL CODES AND REGULATIONS. 6) MAINTAIN A CLEAN AND SAFE WORK-SITE AT ALL TIMES. CLEAN UP CONSTRUCTION DEBRIS ON A REGULAR BASIS. 7) INSTALL 2x8 BLOCKING IN LOCATIONS TO BE COORDINATED WITH G.C. AND OWNER. 8) ASBESTOS TEST PERFORMED BY EARTH ENERGY ENVIRONMENT ON 12/20 INDICATED NO PRESENCE OF HAZARDOUS MATERIALS. EXISTING COLOR KEY NEW DEMOLITION BY OWNER EXISTING ELECTRICAL PANEL EXISTING ELECTRICAL PANEL ADJUST EXISTING ELECTRICAL AS NEEDED FOR NEW WALLS AND WINDOWS ADJUST EXISTING ELECTRICAL AS NEEDED FOR NEW WALLS AND WINDOWS EXISTING LIGHT TO REMAIN A3 02 / 17 / 2021 SA R A H & J O H N M I L B U R N R E S I D E N C E R E M O D E L 45 6 S K Y L I N E D R I V E - E S T E S P A R K , C O 8 0 5 1 7 OF 3 SHEET NUMBER ISSUE DATE REVISIONS DEMOLITION AND ELECTRICAL SHEET TITLE - - - CLIENT APPROVEDFINAL SET TO BE USED FOR:ENGINEERING, ESTIMATING, PERMITTING, AND CONSTRUCTION GFCI THIS STRUCTURE MUST CONFORM TO THE 2020 NEC REVIEWED BY SAFEBUILT 02/26/2021 2015 IECC 75% OF LAMPS TO BE OF HIGH EFFICENCY