Loading...
HomeMy WebLinkAboutPLANS Solar 152 Stanley Circle Dr 2023-02-081.1.1 PROJECT NOTES: 1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B) 1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.1.7 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.2.1 SCOPE OF WORK: 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.3.1 WORK INCLUDES: GENERAL NOTES N2017M 1.3.2 PV ROOF ATTACHMENTS - UNIRAC FLASHLOC COMP 1.3.3 PV RACKING SYSTEM INSTALLATION - UNIRAC LIGHT 1.3.4 PV MODULE AND INVERTER INSTALLATION - HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 / ENPHASE IQ8PLUS-72-2-US 1.3.5 PV EQUIPMENT GROUNDING 1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.3.7 PV LOAD CENTERS (IF INCLUDED) 1.3.8 PV METERING/MONITORING (IF INCLUDED) 1.3.9 PV DISCONNECTS 1.3.10 PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.3.11 PV FINAL COMMISSIONING 1.3.12 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE OWNER NAME:MIKE KINGSWOOD AUTHORITIES HAVING JURISDICTION BUILDING: ESTES PARK ZONING: ESTES PARK UTILITY: ESTES PARK UTILITY DESIGN SPECIFICATIONS OCCUPANCY: ІІ CONSTRUCTION: SINGLE-FAMILY ZONING:RESIDENTIAL GROUND SNOW LOAD: 30 PSF WIND EXPOSURE: В WIND SPEED: 140 MPH APPLICABLE CODES & STANDARDS BUILDING: IBC 2018 RESIDENTIAL: IRC 2018 ELECTRICAL: NEC 2020 FIRE:IFC 2018 PROJECT INFORMATION PROJECT MANAGER NAME: PHONE: CONTRACTOR NAME: PHONE: VENTARA DBA PRO BID ENERGY 303-304-6588 DANNY GLENNON B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 T-001.00 COVER PAGE (SHEET 1) 01 AERIAL PHOTO NOT TO SCALE N EW S 02 PLAT MAP NOT TO SCALE SHEET LIST TABLE SHEET NUMBER SHEET TITLE T-001 COVER PAGE G-001 NOTES A-101 SITE PLAN A-102 ELECTRICAL PLAN A-103 SOLAR ATTACHMENT PLAN E-601 LINE DIAGRAM E-602 DESIGN TABLES E-603 PLACARDS S-501 ASSEMBLY DETAILS R-001 RESOURCE DOCUMENT R-002 RESOURCE DOCUMENT R-003 RESOURCE DOCUMENT R-004 RESOURCE DOCUMENT R-005 RESOURCE DOCUMENT R-006 RESOURCE DOCUMENT R-007 RESOURCE DOCUMENT STA N L E Y C I R C L E D R NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp AC KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 ASSESSOR'S #: 3525154027 SCOPE OF WORK SYSTEM SIZE: ATTACHMENT TYPE: MSP UPGRADE: STC: 18 X 400W = 7.200KW PTC: 18 X 371.5W = 6.687KW (18) HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 (18) ENPHASE IQ8PLUS-72-2-US UNIRAC FLASHLOC COMP NO ARRAY 1: WATTS: 2.400 KW TILT: 30 DEGREES AZIMUTH: 100 DEGREES PV WATTS KWH'S/YR: _______KWH/S. ARRAY 2: WATTS: 4.800 KW TILT: 30 DEGREES AZIMUTH: 270 DEGREES PV WATTS KWH'S/YR: _______KWH/S. TOTAL PV WATTS KWH'S/YR: _______KWH/S. 2/10/2023 2.1.1 SITE NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.2.1 EQUIPMENT LOCATIONS: 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). 2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.3.1 STRUCTURAL NOTES: 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS. 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 2.4.1 WIRING & CONDUIT NOTES: 2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 2.4.4 VOLTAGE DROP LIMITED TO 1.5%. 2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GRAY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. 2.5.1 GROUNDING NOTES: 2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICROINVERTER MANUFACTURERS' INSTRUCTIONS. 2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D). 2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. 2.7.1 INTERCONNECTION NOTES: 2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)] 2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)]. 2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)]. 2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C). 2.7.6 FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (B)(2)(1) 2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)]. N2017M N2017M B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 G-001.00 NOTES (SHEET 2) 2/10/2023 A-101.00 SITE PLAN (SHEET 3) ENTRANCE B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 01/32" = 1'-0" SITE PLAN01 16' 32' N EW S N EW S AREA OF WORK PROPERTY LINE GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ST A N L E Y C I R C L E D R AC COMBINER BOX AC DISCONNECT METER/COMBO 49'-8" 58'-1" 83'-5" 87'-6" 2/10/2023 MODULE: HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400 WATTS 41.1" 74" B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 A-102.00 ELECTRICAL PLAN (SHEET 4) 01/8" = 1'-0" ELECTRICAL PLAN014' 8' N EW S A MODULE STRINGING B MODULE STRINGING FIRE CLEARANCE GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE (N) (1) AC COMBINER BOX (N) (1) AC DISCONNECT EXTERIOR PV EQUIPMENT INTERIOR PV EQUIPMENT (E) (1) METER/COMBO (E) (1) SUB PANEL (N) (1) JUNCTION BOX 18 IN. FIRE ACCESS PATH 18 IN. FIRE ACCESS PATH 3 FT. FIRE ACCESS PATH 3 FT. FIRE ACCESS PATH 18 IN. FIRE ACCESS PATH 18 IN. FIRE ACCESS PATH 3 FT. FIRE ACCESS PATH 18 IN. FIRE ACCESS PATH 18 IN. FIRE ACCESS PATH ARRAY 1 - 4.800 KW [x12] (N) MODULES TILT: 30 DEGREES ROOF PITCH: 7:12 AZIMUTH: 190 DEGREES ARRAY 2 - 2.400 kW [x6] (N) MODULES TILT: 30 DEGREES ROOF PITCH: 7:12 AZIMUTH: 100 DEGREES A A AAA AAAAВВВ В В В В В В 2/10/2023 MODULE: HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400 WATTS 41.1" 74" B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 A-103.00 SOLAR ATTACHMENT PLAN (SHEET 5) 01/8" = 1'-0" SOLAR ATTACHMENT PLAN014' 8' N EW S ROOF RAFTERS GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE (SEE SHEET S-501 FOR MOUNTING DETAILS) ROOF MATERIAL IS ASPHALT SHINGLE 27'-7" 17'-3" 2/10/2023 PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN DISCONNECT PER NEC 690.12 SYSTEM COMPLIANT WITH NEC 690.13 EQUIPMENT LEFT OF LINE IS (N) NEW UNLESS OTHERWISE NOTED. EQUIPMENT RIGHT OF LINE IS (E) EXISTING UNLESS OTHERWISE NOTED. (N) AC COMBINER BOX, 125A ENPHASE IQ COMBINER 4 (X-IQ-AM1-240-4) 120/240V, 1Ø, 3W MAX. CONTINUOUS CURRENT: 65A MAX. OCPD: 90A L1 N L2 ENPHASE ENVOY COMMUNICATIONS GATEWAY G CB3 15A CB1 20A CB2 20A 2 (E) GROUNDING ELECTRODE GROUND ROD TO UTILITY GRID (OH) L2 N L1 (Е) SUB PANEL 240/120 V 1Ø, 3W MAIN BUSS: 125A MAX BREAKER SIZE: (125A X 1.2) - 100A = 50A (E) UTILITY METER GN GN TO (E) LOADS (E) MAIN 100A 3 L2 L1 N L2 L1 N (N) 30A/2P CB4 G SW1 (N) AC DISCONNECT, 30A BLACK RED G BLACK RED IN BRANCH IN BRANCH 1 (N) (18) HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400 WATTS (N) (18) ENPHASE IQ8PLUS-72-2-US RATED POWER: 290W (N) JUNCTION BOX A 9 B 9 PROJECT DESCRIPTION TO INCLUDE: SYSTEM DC RATING: 7.200KW INSTALL TYPE: ROOF BATTERY: NO AHJ: ESTES PARK UTILITY: ESTES PARK UTILITY PROJECT SPECIFICATIONS TO INCUDE: SYSTEM AC RATING: SYSTEM SIZE: 5.220KW MAX AC CURRENT: 21.78A MAX AC POWER: 5.220 KVA NOMINAL OPERATING AC VOLTAGE: 240V (Е) METER/COMBO 240/120 V 1Ø, 3W MAIN BUSS: 125A CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%)BASE AMP.DERATED AMP.TERM. TEMP. RATING AMP. @ TERMINAL 1 1 10 AWG THWN-2, COPPER 0.75'' DIA EMT 4 20A 10 AWG THWN-2, COPPER 0.91 (35.3 °C)0.8 10.89A 13.61A 40A 29.12A 75°C 35A 2 1 10 AWG THWN-2, COPPER 0.75'' DIA EMT 2 N/A 10 AWG THWN-2, COPPER 0.91 (35.3 °C)1 21.78A 27.23A 40A 36.4A 75°C 35A 3 1 10 AWG THWN-2, COPPER 0.75'' DIA EMT 2 30A 10 AWG THWN-2, COPPER 0.91 (35.3 °C)1 21.78A 27.23A 40A 36.4A 75°C 35A B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 E-601.00 LINE DIAGRAM (SHEET 6) MODULE STRINGING MODULE STRINGING A B 2/10/2023 DISCONNECTS INVERTERS OCPDS MODULES ASHRAE EXTREME LOW -27°C (-16.6°F), SOURCE: FORT COLLINS (AWOS) (40.45°; -105°) ASHRAE 2% HIGH 35.3°C (95.5°F), SOURCE: FORT COLLINS (AWOS) (40.45°; -105°) REF.QTY.RATED CURRENT MAX VOLTAGE CB1-2 2 20A 240VAC CB3 1 15A 240VAC CB4 2 30A 240VAC REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 SQUARE D DU221RB OR EQUIV.30A 240VAC REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-18 18 HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400W 371.5W 11.14A 10.77A 45.3V 37.13V -0.122V/°C (-0.27%/°C)20A REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-18 18 ENPHASE IQ8PLUS-72-2-US 240V FLOATING 20A 290W 1.21A 15A 60V 97.0% SYSTEM SUMMARY BRANCH #1 BRANCH #2 INVERTERS PER BRANCH 9 9 MAX AC CURRENT 10.89A 10.89A MAX AC OUTPUT POWER 2,610W 2,610W ARRAY STC POWER 7,200W ARRAY PTC POWER 6,687W MAX AC CURRENT 21.78A MAX AC POWER 5,220W DERATED (CEC) AC POWER 5,220W BILL OF MATERIALS CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION MODULE HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 PM1-18 18 PIECES 1 HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400W 144 HALF-CELLS, MONOCRYSTALLINE SILICON INVERTER ENPHASE IQ8PLUS-72-2-US I1-18 18 PIECES 1 ENPHASE IQ8PLUS-72-2-US 290W INVERTER DISCONNECT SQUARE D DU222RB SW1 1 PIECE 1 SQUARE D DU222RB, NON FUSED, 2-POLE, 60A, 240VAC OR EQUIVALENT MISC ELECTRICAL EQUIPMENT GEN-CABLE-CLIP HDWR21-111 90 PIECES 1 GENERIC CABLE CLIP AC COMBINER PANEL ENPHASE-IQ4-PANEL EP1 1 PIECE 1 ENPHASE IQ COMBINER 4 (X-IQ-AM1-240-4) WIRING ENPHASE Q-12-20-200 EN1-18 18 PIECES 1 ENPHASE ENGAGE (TM) TRUNK CABLE WIRING ENPHASE Q-TERM-10 EN19 1 BUNDLE 10 ENPHASE ENGAGE (TM) BRANCH TERMINATOR WIRING ENPHASE Q-SEAL-10 EN20 1 BUNDLE 10 ENPHASE ENGAGE (TM) WATERTIGHT SEALING CAP WIRING GEN-10-AWG-THWN-2-CU-RD WR1-3 110 FEET 1 10 AWG THWN-2, COPPER, RED (LINE 1) WIRING GEN-10-AWG-THWN-2-CU-BLK WR1-3 110 FEET 1 10 AWG THWN-2, COPPER, BLACK (LINE 2) WIRING GEN-10-AWG-THWN-2-CU-WH WR2-3 20 FEET 1 10 AWG THWN-2, COPPER, WHITE (NEUTRAL) WIRING GEN-10-AWG-THWN-2-CU-GR WR1-3 65 FEET 1 10 AWG THWN-2, COPPER, GREEN (GROUND) WIREWAY ENPHASE ET-SPLK-05 EN5 1 BUNDLE 5 ENPHASE ENGAGE (TM) ENGAGE COUPLER WIREWAY GEN-EMT-0.75'' DIA WW1-4 65 FEET 1 EMT CONDUIT, 0.75'' DIA OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC CB1-2 2 PIECES 1 CIRCUIT BREAKER, 20A, 240VAC OCPD GENERIC MANUFACTURER GEN-CB-15A-240VAC CB3 1 PIECE 1 CIRCUIT BREAKER, 15A, 240VAC OCPD GENERIC MANUFACTURER GEN-CB-30A-240VAC CB4 1 PIECE 1 CIRCUIT BREAKER, 30A, 240VAC TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB-4-4X JB1 1 PIECE 1 TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKS B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 E-602.00 DESIGN TABLES (SHEET 7) 2/10/2023 B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 E-603.00 PLACARDS (SHEET 8) N E W S !CAUTION! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: MAIN DISTRIBUTION UTILITY DISCONNECT FRONT BACK LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED BACKGROUND; “WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVE YELLOW BACKGROUND. [ANSI Z535] ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL 1 AT EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (2" X 4"). [NEC 690.13]. POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING LABEL 2 AT POINT OF INTERCONNECTION OVERCURRENT DEVICE (2" X 4"). [NEC 705.12(B)(2)(3)(B)]. LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS (4" X 3"). [NEC 690.54] LABEL 4 AT EACH AC DISCONNECTING MEANS (4" X 1"). [NEC 690.13(B)]. DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8"). [NEC 690.56(B)] WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV SYSTEM DISCONNECTING MEANS. PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BATHROOMS [NEC 690.4(D),(E)] PHOTOVOLTAIC POWER SOURCE LABEL 9 AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS (5 3/4" X 1 1/8"). [NEC 690.31(G)] LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS LABEL 6 AT RAPID SHUTDOWN SYSTEM (3 3/4" X 5 1/4"). [NEC 690.56(C)(1)(A)]. WARNING LABEL 7 AT POINT OF INTERCONNECTION (2 3/4" X 1 5/8"). [NEC 705.12(B)(3)] WARNING SOLAR ELECTRIC CIRCUIT BREAKER IS BACKFEED LABEL 8 AT POINT OF INTERCONNECTION (2" X 1"). [NEC 705.12(B)(3)] CAUTION SOLAR ELECTRIC SYSTEM CONNECTED LABEL 10 AT UTILITY METER (5 3/4" X 1 1/8") [NEC 690.56(B)] RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL 5 AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2"). [NEC 690.56(C)(3)]. AC DISCONNECT PHOTOVOLTAIC SYSTEM POWER SOURCE RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE AMPS VOLTS PHOTOVOLTAIC SYSTEM DISCONNECT INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED WEST SIDE OF THE HOUSE 21.78 240 DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM PV ARRAY PV ARRAY 2/10/2023 SHEET KEYNOTES 1. ROOF MATERIAL: ASPHALT SHINGLE 2. ROOF STRUCTURE: KNEE WALL 3. ATTACHMENT TYPE: UNIRAC FLASHLOC 4. MODULE MANUFACTURER: HANWHA Q-CELLS 5. MODULE MODEL: Q.PEAK DUO BLK ML-G10+ 400 6. MODULE LENGTH: 74'' 7. MODULE WIDTH: 41.1'' 8. MODULE WEIGHT: 48.5 LBS. 9. SEE SHEET A-103 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 18" FROM RIDGE, 36" FROM EDGE 11. RAFTER SPACING: 24 IN. O.C. 12. RAFTER SIZE: 2Х4 IN. NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 3-1/2 IN. 15. TOTAL # OF ATTACHMENTS: 40 16. TOTAL AREA: 380.18 SQ. FT. 17. TOTAL WEIGHT: 976.38 LBS. 18. WEIGHT PER ATTACHMENT: 24.41 LBS. 19. DISTRIBUTED LOAD: 2.57 PSF 20. MAX. HORIZONTAL STANDOFF: 48 IN. 21. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITH MODULE MANUFACTURER'S INSTRUCTIONS 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER (OR EQUIV.): UNIRAC 24. RAIL MODEL (OR EQUIVALENT): LIGHT 25. RAIL WEIGHT: 0.491 PLF. 26. MAX. RAFTER SPAN: 8 FT. 27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. S-501 D5 20 11 121413151822 RO O F S L O P E 910 10 6 21 7 S-501 D4 3 1 54 252423 8 27 1 2 1. FIELD VERIFY ALL MEASUREMENTS GENERAL NOTES SS LAG BOLT W/ SS EPDM BONDED WASHER SS SERRATED T-BOLT SS SERRATED FLANGE NUT FLASHLOC BASE MILL OR DARK B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 02.08.2023 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE S-501.00 ASSEMBLY DETAILS (SHEET 9) 2/10/2023 B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 11.11.2022 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 R-001.00 RESOURCE DOCUMENT (SHEET 10) B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 11.11.2022 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 R-002.00 RESOURCE DOCUMENT (SHEET 11) B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 11.11.2022 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 R-003.00 RESOURCE DOCUMENT (SHEET 12) B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 11.11.2022 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 R-004.00 RESOURCE DOCUMENT (SHEET 13) B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 11.11.2022 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 R-005.00 RESOURCE DOCUMENT (SHEET 14) B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 11.11.2022 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 R-006.00 RESOURCE DOCUMENT (SHEET 15) B F A D E 2 3 DESIGN BY: A C D E G H B C F G H 1 4 5 6 DATE: CHECKED BY: REVISIONS V.S. M.M. 11.11.2022 PAPER SIZE: 11" x 17" (ANSI B) V.2.1 ENGINEER OF RECORD UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 7.200 kWp DC / 5.220 kWp АС KINGSWOOD RESIDENCE 152 STANLEY CIRCLE DR ESTES PARK, CO 80517 APN: 3525154027 CONTRACTOR PHONE: LIC. NO.: HIC. NO.: ELE. NO.: ADDRESS: VENTARA DBA PRO BID ENERGY 3975 E. 56TH AVE UNIT B1 COMMERCE CITY, CO 80022 EC.0101800 R-007.00 RESOURCE DOCUMENT (SHEET 16)