HomeMy WebLinkAboutPLANS Solar 152 Stanley Circle Dr 2023-02-081.1.1 PROJECT NOTES:
1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE
(NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS,
AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S
(AHJ) APPLICABLE CODES.
1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM
INSPECTED PRIOR TO PARALLEL OPERATION
1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH
THE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B)
1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND
SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN
PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4:
PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE
INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519
COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY
1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT
FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7.
1.1.7 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE
CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE
IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED
ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3].
1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED
TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE
INSTALLED AS REQUIRED BY THE NEC AND AHJ.
1.2.1 SCOPE OF WORK:
1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE
GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE
RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN,
SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE
PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT.
1.3.1 WORK INCLUDES:
GENERAL NOTES
N2017M
1.3.2 PV ROOF ATTACHMENTS - UNIRAC FLASHLOC COMP
1.3.3 PV RACKING SYSTEM INSTALLATION - UNIRAC LIGHT
1.3.4 PV MODULE AND INVERTER INSTALLATION - HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 /
ENPHASE IQ8PLUS-72-2-US
1.3.5 PV EQUIPMENT GROUNDING
1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX
1.3.7 PV LOAD CENTERS (IF INCLUDED)
1.3.8 PV METERING/MONITORING (IF INCLUDED)
1.3.9 PV DISCONNECTS
1.3.10 PV GROUNDING ELECTRODE & BONDING TO (E) GEC
1.3.11 PV FINAL COMMISSIONING
1.3.12 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV
1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE
OWNER
NAME:MIKE KINGSWOOD
AUTHORITIES HAVING JURISDICTION
BUILDING: ESTES PARK
ZONING: ESTES PARK
UTILITY: ESTES PARK UTILITY
DESIGN SPECIFICATIONS
OCCUPANCY: ІІ
CONSTRUCTION: SINGLE-FAMILY
ZONING:RESIDENTIAL
GROUND SNOW LOAD: 30 PSF
WIND EXPOSURE: В
WIND SPEED: 140 MPH
APPLICABLE CODES & STANDARDS
BUILDING: IBC 2018
RESIDENTIAL: IRC 2018
ELECTRICAL: NEC 2020
FIRE:IFC 2018
PROJECT INFORMATION
PROJECT MANAGER
NAME:
PHONE:
CONTRACTOR
NAME:
PHONE:
VENTARA DBA PRO BID ENERGY
303-304-6588
DANNY GLENNON
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
T-001.00
COVER PAGE
(SHEET 1)
01 AERIAL PHOTO
NOT TO SCALE
N
EW
S
02 PLAT MAP
NOT TO SCALE
SHEET LIST TABLE
SHEET NUMBER SHEET TITLE
T-001 COVER PAGE
G-001 NOTES
A-101 SITE PLAN
A-102 ELECTRICAL PLAN
A-103 SOLAR ATTACHMENT PLAN
E-601 LINE DIAGRAM
E-602 DESIGN TABLES
E-603 PLACARDS
S-501 ASSEMBLY DETAILS
R-001 RESOURCE DOCUMENT
R-002 RESOURCE DOCUMENT
R-003 RESOURCE DOCUMENT
R-004 RESOURCE DOCUMENT
R-005 RESOURCE DOCUMENT
R-006 RESOURCE DOCUMENT
R-007 RESOURCE DOCUMENT
STA
N
L
E
Y
C
I
R
C
L
E
D
R
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp AC
KINGSWOOD RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
ASSESSOR'S #: 3525154027
SCOPE OF WORK
SYSTEM SIZE:
ATTACHMENT TYPE:
MSP UPGRADE:
STC: 18 X 400W = 7.200KW
PTC: 18 X 371.5W = 6.687KW
(18) HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400
(18) ENPHASE IQ8PLUS-72-2-US
UNIRAC FLASHLOC COMP
NO
ARRAY 1:
WATTS: 2.400 KW
TILT: 30 DEGREES
AZIMUTH: 100 DEGREES
PV WATTS KWH'S/YR: _______KWH/S.
ARRAY 2:
WATTS: 4.800 KW
TILT: 30 DEGREES
AZIMUTH: 270 DEGREES
PV WATTS KWH'S/YR: _______KWH/S.
TOTAL PV WATTS KWH'S/YR: _______KWH/S.
2/10/2023
2.1.1 SITE NOTES:
2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS
AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.
2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,
MECHANICAL, OR BUILDING ROOF VENTS.
2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND
PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION
NEC 110.26.
2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN
ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S
INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE
BUILDING OR STRUCTURE.
2.2.1 EQUIPMENT LOCATIONS:
2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY
NEC 110.26.
2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR
EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C)
AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).
2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES
ACCORDING TO NEC 690.34.
2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER
IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.
2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL
ACCORDING TO NEC APPLICABLE CODES.
2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR
OUTDOOR USAGE WHEN APPROPRIATE.
2.3.1 STRUCTURAL NOTES:
2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO
CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A
DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A
MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,
ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS.
2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS.
IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL
REQUIREMENTS.
2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND
SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED
CONTRACTOR.
2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE
SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.
2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE
STAGGERED AMONGST THE ROOF FRAMING MEMBERS.
2.4.1 WIRING & CONDUIT NOTES:
2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.
CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE
REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.
2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.
2.4.4 VOLTAGE DROP LIMITED TO 1.5%.
2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING
SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE
WIRING CLIPS.
2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS:
PHASE A OR L1- BLACK
PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE
PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION
NEUTRAL- WHITE OR GRAY
IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE
TO BE MARKED ORANGE [NEC 110.15].
2.5.1 GROUNDING NOTES:
2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,
AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR
SUCH USE.
2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND
MINIMUM NEC TABLE 250.122.
2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES
CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).
2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC
690.45 AND MICROINVERTER MANUFACTURERS' INSTRUCTIONS.
2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS
SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF
WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT
THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS'
INSTALLATION REQUIREMENTS.
2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH
THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING
CONDUCTOR TO ANOTHER MODULE.
2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED
GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]
2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC
250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR
INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO
NEC 250, NEC 690.47 AND AHJ.
2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO
REDUCE FIRE HAZARDS
2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:
2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH
IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO
THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).
2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE
LOCKABLE, AND BE A VISIBLE-BREAK SWITCH
2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A
RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY
RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D).
2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9,
AND 240.
2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR
GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B).
2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION
ACCORDING TO NEC 690.11 AND UL1699B.
2.7.1 INTERCONNECTION NOTES:
2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC
705.12 (B)]
2.7.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY
NOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)].
2.7.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT
CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE
BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE
BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE
END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)].
2.7.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL
RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF
BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE
EXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C).
2.7.6 FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12
(B)(2)(1)
2.7.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH
SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42
2.7.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT
FROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)].
N2017M
N2017M
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
G-001.00
NOTES
(SHEET 2)
2/10/2023
A-101.00
SITE PLAN
(SHEET 3)
ENTRANCE
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
01/32" = 1'-0"
SITE PLAN01 16' 32'
N
EW
S
N
EW
S
AREA OF WORK
PROPERTY LINE
GENERAL NOTES
1. FIELD VERIFY ALL MEASUREMENTS
2. ITEMS BELOW MAY NOT BE ON THIS PAGE
ST
A
N
L
E
Y
C
I
R
C
L
E
D
R
AC COMBINER BOX
AC DISCONNECT
METER/COMBO
49'-8"
58'-1"
83'-5"
87'-6"
2/10/2023
MODULE:
HANWHA Q-CELLS
Q.PEAK DUO BLK ML-G10+ 400
400 WATTS
41.1"
74"
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
A-102.00
ELECTRICAL PLAN
(SHEET 4)
01/8" = 1'-0"
ELECTRICAL PLAN014' 8'
N
EW
S
A MODULE STRINGING
B MODULE STRINGING
FIRE CLEARANCE
GENERAL NOTES
1. FIELD VERIFY ALL MEASUREMENTS
2. ITEMS BELOW MAY NOT BE ON THIS PAGE
(N) (1) AC COMBINER BOX
(N) (1) AC DISCONNECT
EXTERIOR PV EQUIPMENT
INTERIOR PV EQUIPMENT
(E) (1) METER/COMBO
(E) (1) SUB PANEL
(N) (1) JUNCTION BOX
18 IN. FIRE ACCESS PATH
18 IN. FIRE ACCESS PATH 3 FT. FIRE ACCESS PATH
3 FT. FIRE ACCESS PATH
18 IN. FIRE ACCESS PATH
18 IN. FIRE ACCESS PATH
3 FT. FIRE ACCESS PATH
18 IN. FIRE ACCESS PATH
18 IN. FIRE ACCESS PATH
ARRAY 1 - 4.800 KW
[x12] (N) MODULES
TILT: 30 DEGREES
ROOF PITCH: 7:12
AZIMUTH: 190 DEGREES
ARRAY 2 - 2.400 kW
[x6] (N) MODULES
TILT: 30 DEGREES
ROOF PITCH: 7:12
AZIMUTH: 100 DEGREES
A
A
AAA
AAAAВВВ
В
В
В
В
В
В
2/10/2023
MODULE:
HANWHA Q-CELLS
Q.PEAK DUO BLK ML-G10+ 400
400 WATTS
41.1"
74"
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
A-103.00
SOLAR ATTACHMENT PLAN
(SHEET 5)
01/8" = 1'-0"
SOLAR ATTACHMENT PLAN014' 8'
N
EW
S
ROOF RAFTERS
GENERAL NOTES
1. FIELD VERIFY ALL MEASUREMENTS
2. ITEMS BELOW MAY NOT BE ON THIS PAGE
FLUSH MOUNT SOLAR MODULES
ATTACHED TO ROOF SURFACE (SEE
SHEET S-501 FOR MOUNTING DETAILS)
ROOF MATERIAL IS ASPHALT SHINGLE
27'-7"
17'-3"
2/10/2023
PV SYSTEM EQUIPPED WITH RAPID
SHUTDOWN DISCONNECT PER NEC 690.12
SYSTEM COMPLIANT WITH NEC 690.13
EQUIPMENT LEFT
OF LINE IS (N) NEW
UNLESS OTHERWISE NOTED.
EQUIPMENT RIGHT
OF LINE IS (E) EXISTING
UNLESS OTHERWISE NOTED.
(N) AC COMBINER BOX, 125A
ENPHASE IQ COMBINER 4
(X-IQ-AM1-240-4)
120/240V, 1Ø, 3W
MAX. CONTINUOUS CURRENT: 65A
MAX. OCPD: 90A
L1 N L2
ENPHASE ENVOY
COMMUNICATIONS
GATEWAY
G
CB3
15A
CB1
20A
CB2
20A 2
(E) GROUNDING
ELECTRODE
GROUND
ROD
TO UTILITY
GRID (OH)
L2
N
L1
(Е) SUB PANEL
240/120 V 1Ø, 3W
MAIN BUSS: 125A
MAX BREAKER SIZE:
(125A X 1.2) - 100A = 50A
(E)
UTILITY
METER
GN
GN
TO (E)
LOADS
(E) MAIN
100A
3
L2
L1
N
L2
L1
N (N)
30A/2P
CB4
G
SW1
(N) AC DISCONNECT, 30A
BLACK
RED
G
BLACK
RED
IN BRANCH
IN BRANCH
1
(N) (18) HANWHA Q-CELLS
Q.PEAK DUO BLK ML-G10+ 400
400 WATTS
(N) (18) ENPHASE
IQ8PLUS-72-2-US
RATED POWER: 290W
(N) JUNCTION BOX
A
9
B
9
PROJECT DESCRIPTION TO INCLUDE:
SYSTEM DC RATING: 7.200KW
INSTALL TYPE: ROOF
BATTERY: NO
AHJ: ESTES PARK
UTILITY: ESTES PARK UTILITY
PROJECT SPECIFICATIONS TO INCUDE:
SYSTEM AC RATING:
SYSTEM SIZE: 5.220KW
MAX AC CURRENT: 21.78A
MAX AC POWER: 5.220 KVA
NOMINAL OPERATING AC VOLTAGE: 240V
(Е) METER/COMBO
240/120 V 1Ø, 3W
MAIN BUSS: 125A
CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS
ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING
CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR.
FACTOR
CONDUIT FILL
FACTOR
CONT.
CURRENT
MAX. CURRENT
(125%)BASE AMP.DERATED
AMP.TERM. TEMP. RATING AMP. @ TERMINAL
1 1
10 AWG THWN-2, COPPER 0.75'' DIA EMT 4 20A 10 AWG THWN-2, COPPER 0.91 (35.3 °C)0.8 10.89A 13.61A 40A 29.12A 75°C 35A
2 1
10 AWG THWN-2, COPPER 0.75'' DIA EMT 2 N/A 10 AWG THWN-2, COPPER 0.91 (35.3 °C)1 21.78A 27.23A 40A 36.4A 75°C 35A
3 1
10 AWG THWN-2, COPPER 0.75'' DIA EMT 2 30A 10 AWG THWN-2, COPPER 0.91 (35.3 °C)1 21.78A 27.23A 40A 36.4A 75°C 35A
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
E-601.00
LINE DIAGRAM
(SHEET 6)
MODULE STRINGING
MODULE STRINGING
A
B
2/10/2023
DISCONNECTS
INVERTERS
OCPDS
MODULES
ASHRAE EXTREME LOW -27°C (-16.6°F), SOURCE: FORT COLLINS (AWOS) (40.45°; -105°)
ASHRAE 2% HIGH 35.3°C (95.5°F), SOURCE: FORT COLLINS (AWOS) (40.45°; -105°)
REF.QTY.RATED CURRENT MAX VOLTAGE
CB1-2 2 20A 240VAC
CB3 1 15A 240VAC
CB4 2 30A 240VAC
REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE
SW1 1 SQUARE D DU221RB OR EQUIV.30A 240VAC
REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING
PM1-18 18 HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400W 371.5W 11.14A 10.77A 45.3V 37.13V
-0.122V/°C (-0.27%/°C)20A
REF.QTY.MAKE AND MODEL AC
VOLTAGE GROUND OCPD
RATING
RATED
POWER
MAX OUTPUT
CURRENT
MAX INPUT
CURRENT
MAX INPUT
VOLTAGE
CEC WEIGHTED
EFFICIENCY
I1-18 18 ENPHASE IQ8PLUS-72-2-US 240V FLOATING 20A 290W 1.21A 15A 60V 97.0%
SYSTEM SUMMARY
BRANCH #1 BRANCH #2
INVERTERS PER BRANCH 9 9
MAX AC CURRENT 10.89A 10.89A
MAX AC OUTPUT POWER 2,610W 2,610W
ARRAY STC POWER 7,200W
ARRAY PTC POWER 6,687W
MAX AC CURRENT 21.78A
MAX AC POWER 5,220W
DERATED (CEC) AC POWER 5,220W
BILL OF MATERIALS
CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION
MODULE HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 PM1-18 18 PIECES 1
HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400W 144 HALF-CELLS, MONOCRYSTALLINE SILICON
INVERTER ENPHASE IQ8PLUS-72-2-US I1-18 18 PIECES 1 ENPHASE IQ8PLUS-72-2-US 290W INVERTER
DISCONNECT SQUARE D DU222RB SW1 1 PIECE 1
SQUARE D DU222RB, NON FUSED, 2-POLE, 60A, 240VAC OR EQUIVALENT
MISC ELECTRICAL EQUIPMENT GEN-CABLE-CLIP HDWR21-111 90 PIECES 1 GENERIC CABLE CLIP
AC COMBINER PANEL ENPHASE-IQ4-PANEL EP1 1 PIECE 1
ENPHASE IQ COMBINER 4 (X-IQ-AM1-240-4)
WIRING ENPHASE Q-12-20-200 EN1-18 18 PIECES 1 ENPHASE ENGAGE (TM) TRUNK CABLE
WIRING ENPHASE Q-TERM-10 EN19 1 BUNDLE 10
ENPHASE ENGAGE (TM) BRANCH TERMINATOR
WIRING ENPHASE Q-SEAL-10 EN20 1 BUNDLE 10
ENPHASE ENGAGE (TM) WATERTIGHT SEALING CAP
WIRING GEN-10-AWG-THWN-2-CU-RD WR1-3 110 FEET 1
10 AWG THWN-2, COPPER, RED (LINE 1)
WIRING GEN-10-AWG-THWN-2-CU-BLK WR1-3 110 FEET 1
10 AWG THWN-2, COPPER, BLACK (LINE 2)
WIRING GEN-10-AWG-THWN-2-CU-WH WR2-3 20 FEET 1 10 AWG THWN-2, COPPER, WHITE (NEUTRAL)
WIRING GEN-10-AWG-THWN-2-CU-GR WR1-3 65 FEET 1
10 AWG THWN-2, COPPER, GREEN (GROUND)
WIREWAY ENPHASE ET-SPLK-05 EN5 1 BUNDLE 5
ENPHASE ENGAGE (TM) ENGAGE COUPLER
WIREWAY GEN-EMT-0.75'' DIA WW1-4 65 FEET 1
EMT CONDUIT, 0.75'' DIA
OCPD GENERIC MANUFACTURER GEN-CB-20A-240VAC CB1-2 2 PIECES 1
CIRCUIT BREAKER, 20A, 240VAC
OCPD GENERIC MANUFACTURER GEN-CB-15A-240VAC CB3 1 PIECE 1
CIRCUIT BREAKER, 15A, 240VAC
OCPD GENERIC MANUFACTURER GEN-CB-30A-240VAC CB4 1 PIECE 1
CIRCUIT BREAKER, 30A, 240VAC
TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB-4-4X JB1 1 PIECE 1
TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKS
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
E-602.00
DESIGN TABLES
(SHEET 7)
2/10/2023
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
E-603.00
PLACARDS
(SHEET 8)
N
E
W
S
!CAUTION!
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM ROOF MOUNTED SOLAR ARRAYS WITH
SAFETY DISCONNECTS AS SHOWN:
MAIN DISTRIBUTION
UTILITY DISCONNECT
FRONT BACK
LABELING NOTES
1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE,
INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535
1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING
JURISDICTION.
1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED.
1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED
BACKGROUND; “WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVE
YELLOW BACKGROUND. [ANSI Z535]
ELECTRICAL SHOCK HAZARD
TERMINALS ON THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
WARNING
LABEL 1
AT EACH DISCONNECTING MEANS FOR
PHOTOVOLTAIC EQUIPMENT (2" X 4").
[NEC 690.13].
POWER SOURCE
OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
WARNING
LABEL 2
AT POINT OF INTERCONNECTION
OVERCURRENT DEVICE (2" X 4").
[NEC 705.12(B)(2)(3)(B)].
LABEL 3
AT POINT OF INTERCONNECTION, MARKED
AT DISCONNECTING MEANS (4" X 3").
[NEC 690.54]
LABEL 4
AT EACH AC DISCONNECTING MEANS
(4" X 1").
[NEC 690.13(B)].
DIRECTORY
PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE
DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING
MEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8").
[NEC 690.56(B)]
WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A
DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV
SYSTEM DISCONNECTING MEANS.
PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN
BATHROOMS
[NEC 690.4(D),(E)]
PHOTOVOLTAIC POWER SOURCE
LABEL 9
AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING
METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE
SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS,
OR FLOORS (5 3/4" X 1 1/8").
[NEC 690.31(G)]
LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND;
REFLECTIVE
[IFC 605.11.1.1]
SOLAR PV SYSTEM
EQUIPPED WITH
RAPID SHUTDOWN
TURN RAPID SHUTDOWN SWITCH TO
THE "OFF" POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE SHOCK
HAZARD IN ARRAY
SOLAR ELECTRIC
PV PANELS
LABEL 6
AT RAPID SHUTDOWN SYSTEM
(3 3/4" X 5 1/4"). [NEC 690.56(C)(1)(A)].
WARNING
LABEL 7
AT POINT OF INTERCONNECTION
(2 3/4" X 1 5/8").
[NEC 705.12(B)(3)]
WARNING
SOLAR ELECTRIC
CIRCUIT BREAKER
IS BACKFEED
LABEL 8
AT POINT OF INTERCONNECTION
(2" X 1").
[NEC 705.12(B)(3)]
CAUTION
SOLAR ELECTRIC SYSTEM CONNECTED
LABEL 10
AT UTILITY METER (5 3/4" X 1 1/8")
[NEC 690.56(B)]
RAPID SHUTDOWN
SWITCH FOR
SOLAR PV SYSTEM
LABEL 5
AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2").
[NEC 690.56(C)(3)].
AC DISCONNECT
PHOTOVOLTAIC SYSTEM
POWER SOURCE
RATED AC
OUTPUT CURRENT
NOMINAL OPERATING
AC VOLTAGE
AMPS
VOLTS
PHOTOVOLTAIC SYSTEM
DISCONNECT
INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED
PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED
WEST SIDE OF THE HOUSE
21.78
240
DUAL POWER SUPPLY
SOURCES: UTILITY GRID
AND PV SOLAR
ELECTRIC SYSTEM
PV ARRAY
PV ARRAY
2/10/2023
SHEET KEYNOTES
1. ROOF MATERIAL: ASPHALT SHINGLE
2. ROOF STRUCTURE: KNEE WALL
3. ATTACHMENT TYPE: UNIRAC FLASHLOC
4. MODULE MANUFACTURER: HANWHA Q-CELLS
5. MODULE MODEL: Q.PEAK DUO BLK ML-G10+ 400
6. MODULE LENGTH: 74''
7. MODULE WIDTH: 41.1''
8. MODULE WEIGHT: 48.5 LBS.
9. SEE SHEET A-103 FOR DIMENSION(S)
10. MIN. FIRE OFFSET: 18" FROM RIDGE, 36" FROM EDGE
11. RAFTER SPACING: 24 IN. O.C.
12. RAFTER SIZE: 2Х4 IN. NOMINAL
13. LAG BOLT DIAMETER: 5/16 IN.
14. LAG BOLT EMBEDMENT: 3-1/2 IN.
15. TOTAL # OF ATTACHMENTS: 40
16. TOTAL AREA: 380.18 SQ. FT.
17. TOTAL WEIGHT: 976.38 LBS.
18. WEIGHT PER ATTACHMENT: 24.41 LBS.
19. DISTRIBUTED LOAD: 2.57 PSF
20. MAX. HORIZONTAL STANDOFF: 48 IN.
21. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITH
MODULE MANUFACTURER'S INSTRUCTIONS
22. STANDOFF STAGGERING: YES
23. RAIL MANUFACTURER (OR EQUIV.): UNIRAC
24. RAIL MODEL (OR EQUIVALENT): LIGHT
25. RAIL WEIGHT: 0.491 PLF.
26. MAX. RAFTER SPAN: 8 FT.
27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX.
S-501
D5
20
11
121413151822
RO
O
F
S
L
O
P
E
910
10
6 21
7
S-501
D4
3
1
54
252423
8
27
1 2
1. FIELD VERIFY ALL MEASUREMENTS
GENERAL NOTES
SS LAG BOLT
W/ SS EPDM BONDED WASHER
SS SERRATED T-BOLT
SS SERRATED FLANGE NUT
FLASHLOC BASE
MILL OR DARK
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
02.08.2023
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
D4 DETAIL (TRANSVERSE)
NOT TO SCALE D5 DETAIL (LONGITUDINAL)
NOT TO SCALE
D1 RACKING DETAIL (TRANSVERSE)
NOT TO SCALE
D3 RACKING DETAIL (TOP)
NOT TO SCALE
D2 RACKING DETAIL (LONGITUDINAL)
NOT TO SCALE
S-501.00
ASSEMBLY DETAILS
(SHEET 9)
2/10/2023
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
11.11.2022
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
R-001.00
RESOURCE DOCUMENT
(SHEET 10)
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
11.11.2022
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
R-002.00
RESOURCE DOCUMENT
(SHEET 11)
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
11.11.2022
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
R-003.00
RESOURCE DOCUMENT
(SHEET 12)
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
11.11.2022
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
R-004.00
RESOURCE DOCUMENT
(SHEET 13)
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
11.11.2022
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
R-005.00
RESOURCE DOCUMENT
(SHEET 14)
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
11.11.2022
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
R-006.00
RESOURCE DOCUMENT
(SHEET 15)
B F
A D E
2
3
DESIGN BY:
A C D E G H
B C F G H
1
4
5
6
DATE:
CHECKED BY:
REVISIONS
V.S.
M.M.
11.11.2022
PAPER SIZE: 11" x 17" (ANSI B)
V.2.1
ENGINEER OF RECORD
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM:
7.200 kWp DC / 5.220 kWp АС
KINGSWOOD
RESIDENCE
152 STANLEY CIRCLE DR
ESTES PARK, CO 80517
APN: 3525154027
CONTRACTOR
PHONE:
LIC. NO.:
HIC. NO.:
ELE. NO.:
ADDRESS:
VENTARA DBA PRO BID ENERGY
3975 E. 56TH AVE UNIT B1
COMMERCE CITY, CO 80022
EC.0101800
R-007.00
RESOURCE DOCUMENT
(SHEET 16)