Loading...
HomeMy WebLinkAboutPLANS Deck 475 Pioneer Ln 2023-06-06FRAMING NOTES STRUCTURAL WOOD FRAMING: A. EXCEPT WHERE NOTED OTHERWISE, ALL 2" LUMBER SHALL BE WEATHER TREATED DOUGLAS FIR S4S #2 OR BETTER, AND ALL SOLID TIMBER BEAMS AND POSTS SHALL BE DOUGLAS FIR-LARCH #2, UNLESS OTHERWISE NOTED. B. PROVIDE SOLID BLOCKING AT SUPPORTS FOR WOOD JOISTS. WITHIN DECK JOIST SPACES BENEATH SOLID OR BUILT-UP COLUMNS NOTED ON PLANS, BLOCKING OF AREA EQUIVALENT TO COLUMN ABOVE SHALL BE PROVIDED FOR PROPER LOAD TRANSFER. C. UNLESS OTHERWISE NOTED, STEEL CONNECTORS SUCH AS THOSE MANUFACTURED BY THE SIMPSON COMPANY SHALL BE USED TO JOIN BEAMS, JOISTS, OR POSTS TO OTHER MEMBERS AT FLUSH-FRAMED CONDITIONS. CONNECTOR CONDITIONS NOT OTHERWISE NOTED SHALL UTILIZE HANGERS OF A SIZE SPECIFICALLY DESIGNED FOR THE MEMBER SUPPORTED, AS SHOWN IN MANUFACTURER'S PUBLISHED TABLES. D. ALL WOOD FRAMING MEMBERS IN CONTACT WITH CONCRETE OR CMU SHALL BE WEATHER TREATED. E. JOIST TAPE TO BE USED ON TOP FACING SURFACES OF ALL DECK FRAMING. LOCATION INFORMATION ADDRESS: 475 Pioneer Ln Estes Park CO 80517 PARCEL NUMBER: 3524105004 SCHEDULE: 0601217 LOT INFORMATION: LOT SIZE: 1.0 ACRES ZONING: E-1 ESTATE DESIGN CRITERIA PROJECT TEAM CLIENT / OWNER RICHARD HOWARD 475 PIONEER LN ESTES PARK CO 80517 CONTRACTOR DRAFTING / PLANWORK VOYAGER ONE DESIGN COMPANY STEVE RANDALL (970) 443.0704 VoyagerOneDesign@gmail.com ENGINEER OF RECORD VAN HORN ENGINEERING FRANK ROBERTS (970) 586-9388 Frank@vanhornengineering.com GENERAL PROJECT NOTES 1) DIMENSIONS ARE TYPICALLY TO FACE OF MASONRY OR CONCRETE, AND FACE OF FRAMING MEMBER, UNLESS NOTED OTHERWISE. 2) THIS PROJECT IS IN ADDITION TO AN EXISTING STRUCTURE AND DIMENSIONS MAY NEED TO BE VERIFIED AND/OR ADJUSTED IN FIELD. 3) ALL DIMENSIONS MARKED WITH ± ARE APPROXIMATE. 4) INSPECT AND VERIFY EXISTING CONDITIONS. NOTIFY G.C. OR OWNER OF ANY DISCREPANCIES OR QUESTIONS. 5) ALL WORK SHALL COMPLY WITH LOCAL CODES AND REGULATIONS. 6) MAINTAIN A CLEAN AND SAFE WORK-SITE AT ALL TIMES. CLEAN UP CONSTRUCTION DEBRIS ON A REGULAR BASIS. 7) THE AGE AND CONDITION OF EXISTING STRUCTURE SUGGESTS NO PRESENCE OF ASBESTOS OR HAZARDOUS MATERIALS. SHALL ANY SUSPICIOUS MATERIALS BE DISCOVERED, THE G.C. SHALL HALT WORK UNTIL TESTING AND PROPER DISPOSAL CAN BE ACCOMPLISHED. 8) ALL NEW MATERIALS AND FINISHES SHALL MATCH EXISTING UNLESS SPECIFIED IN THESE DRAWINGS OR DICTATED BY CLIENT/OWNER. COORDINATE ALL FINAL SELECTIONS WITH G.C. AND CLIENT/OWNER PRIOR TO ORDERING OR INSTALLING. 9) ALL FRAMING AND LUMBER TO BE TREATED OR SIMILAR WEATHER TREATED MATERIAL UNLESS OTHERWISE NOTED. TOP OF JOIST TO BE COATED WITH WEATHER TREATMENT. 10) NOTICE: USE OF THESE PLANS CONTEMPLATES FURTHER COORDINATION AMONG THE OWNER AND THEIR CONTRACTOR(S), THE DESIGNER, AND THE ENGINEERS. DESIGN AND CONSTRUCTION ARE COMPLEX. ALTHOUGH THE DESIGNER AND OTHER CONSULTANTS HAVE PERFORMED THEIR SERVICES WITH DUE CARE, ADN DILIGENCE, THEY CANNOT GUARANTEE PERFECTION. COMMUNICATION IS IMPERFECT, AND EVERY CONTINGENCY CANNOT BE ANTICIPATED. ANY AMBIGUITY OR DISCREPANCY DISCOVERED BY THE USE OF THESE PLANS SHALL BE REPORTED IMMEDIATELY TO ORIGINATOR OR SAID PLANS. A NOTICE OF FAILURE TO COOPERATE SHALL RELIEVE THE DESIGNER / ARCHITECT / ENGINEER / DESIGNER FROM RESPONSIBILITY FOR ANY CONSEQUENCES. CHANGES MADE FROM THE PLANS WITHOUT CONSENT OF THE DESIGNER SHALL RELIEVE THE DESIGNER OF RESPONSIBILITY FOR ALL CONSEQUENCES CAUSE BY SUCH CHANGES. FOUNDATION NOTES FOUNDATION DESIGN: DESIGN OF PIERS BASED ON PERFORMANCE OF EXISTING PIERS AND A MAXIMUM ALLOWABLE BEARING PRESSURE OF 2500 LBS PER SQUARE FOOT (DEAD LOAD PLUS FULL LIVE LOAD) PLACED ON THE UNDISTURBED NATURAL SOILS, COMPACTED STRUCTURAL FILL OR NATIVE STONE, BELOW FROST DEPTH. CAST-IN-PLACE CONCRETE: A. ALL CONCRETE DESIGN IS BASED ON THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318). B. ALL STRUCTURAL CONCRETE SHALL HAVE MINIMUM 28-DAY COMPRESSIVE STRENGTHS AS FOLLOWS: FOOTINGS 3000 PSI; SLABS ON GRADE 3500 PSI. C. CONCRETE SHALL BE PROPORTIONED UTILIZING TYPE I/II CEMENT. CONCRETE SUSCEPTIBLE TO FREEZING SHALL BE FORMULATED FOR MAXIMUM FROST RESISTANCE IN ACCORDANCE WITH "ACI MANUAL OF CONCRETE PRACTICE". D. ALL ANCHOR BOLTS SHALL BE LOCATED AT A MINIMUM OF 5 BOLT DIAMETERS FROM CONCRETE EDGE. CONCRETE FOOTING AND FOUNDATION SHALL HAVE MIN FROST PROTECTION OF 30" TO GRADE. EXTERIOR DECK PIERS SHALL BE POURED TO ELEVATIONS AS SHOWN ON PLANS, MIN 6" ABOVE FINISHED GRADE. E. CONTRACTOR VERIFY TOP OF CONCRETE ELEVATIONS WITH EXISTING AND PROPOSED GRADE. REINFORCING STEEL: A. ALL DETAILING, FABRICATION, AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE "ACI MANUAL OF CONCRETE PRACTICE". B. REINFORCING BARS SHALL CONFORM TO ASTM SPECIFICATION A615 AND SHALL BE GRADE 60, EXCEPT TIES, FIELD BENT BARS WHERE PERMITTED BY NOTE ON PLAN, OR BARS TO BE WELDED WHICH SHALL BE GRADE 40. ANCHOR BOLTS: A. SHALL CONFORM TO ASTM F1554 GRADE 36 WITH A MIN ½" DIAMETER BY 8" LENGTH. B. POST INSTALLED ANCHORS TO BE DRILLED AND EPOXIED W/ SIMPSON AT-XP ACRYLIC ADHESIVE AND 6" MINIMUM EMBEDMENT. APPLICABLE CODES: 2015 International Residential Code (IRC) COUNTY: Town of ESTES PARK ZONING CLASSIFICATION: E-1 ESTATE Setbacks 25' front, 5' sides, 10' rear Maximum Height 30'-0" Minimum Width 20'-0" OCCUPANCY: Single Family Residence FEMA FLOOD ZONE: X, area of minimal flood hazard Project Elevation: 7843’ Ground Snow Load (Pg) 69 psf Wind Speed: 175 mph Exposure C Seismic Design Category: B Assumed Soil Bearing Pressure: 2,500 psf Vicinity Map Project Address: 475 Pioneer Ln Estes Park CO 80517 34 B l a c k C a n y o n D r 7 Deck and Wall - Section View Scale: 3/16" = 1'-0"7Deck South Facing Elevation Scale: 1/4" = 1'-0"5 New Framing - Isometric View Scale: N/A3 New Deck Isometric View Scale: N/A1 New Foundation - Plan View Scale: 1/4" = 1'-0"6 New Framing - Plan View Scale: 1/4" = 1'-0"4 New Deck - Plan View Scale: 1/4" = 1'-0"2 New Deck - Post and Railing Detail Scale: 1/2" = 1'-0"9 TREX TRANSCEND LINE OF DECKING, COLOR: ROPE SWING 2 5 / 8 " RDI POSTS AND RAILING 7 A1 8 A1 6 1/2" RE-USE EXISTING 2X8 DECK FRAMING ADD NEW 2X8 JOISTS @ 24" O.C. VERIFY ALL JOISTS HAVE JOIST HANGERS INSTALLED NEW JOIST TAPE TOP SIDE OF ALL JOISTS EXISTING 8" DECK PIERS NEW 10" DECK PIERS New Deck Railing and Pier - Detail Scale: 1/2" = 1'-0"8 Site Plan 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATIONS AND PROTECTION OF ALL EXISTING UTILITIES. CONTRACTOR SHALL CONTACT REPRESENTATIVES FROM THE RESPECTIVE UTILITY COMPANIES TO HAVE ALL OF THEIR UTILITIES AND FACILITIES LOCATED PRIOR TO WORK PROCEEDING. 2. CONTRACTOR SHALL PROTECT ALL ADJACENT IMPROVEMENTS FROM DAMAGE AND EROSION. ALL DISTURBED AREAS SHALL BE RESTORED TO A MINIMUM OF THEIR ORIGINAL CONDITION. 3. LOCATION OF EXISTING HOUSE AND DECK ON LOT APPROXIMATED FROM AERIAL IMAGERY AS SHOWN ON LARIMER COUNTY ASSESSOR GIS. 4. PROPOSED DECK IS TO BE OVER EXISTING DECK FOOTPRINT, WHICH IS ASSUMED TO HAVE BEEN PREVIOUSLY PERMITTED IN IT'S CURRENT LOCATION AND SIZE, CONTRACTOR TO VERIFY. Ma c G r e g o r A v e 34 Project Site 475 Pioneer Ln EXISTING POSTS TO BE CUT FLUSH WITH TOP OF JOISTS, VERIFY EXISTENCE OF (2) GALVANIZED ½" THRU BOLTS EACH POST STAIN / SEAL END GRAIN OF ALL POSTS MAXIMUM 4" Φ SPHERICAL OPENING RDI METAL RAILING (2) ½" GALVANIZED BOLTS TREX DECKING: TRANSCEND LINE, COLOR: ROPE SWING RDI AVALON TOP RAILING AND POST CAPS (2) ½" GALVANIZED BOLTS EXISTING 2X8 RIM JOIST SIMPSON AB POST BASE CONNECTION (2) #4 VERTICAL REBAR EACH PIER POSSIBLE SHALLOW ROCK CONDITIONS, DRILL AND EPOXY AS NEEDED W/ MIN 6" EMBED NEW 8" CONCRETE PIER RDI METAL POST W/ POST CAP SIMPSON LUS28 DECK JOIST HANGER PROJECT NARRATIVE THE EXISTING DECK BOARDS ARE STARTING TO ROT OUT AND THE EXISTING RAILING DOES NOT MEET RESIDENTIAL BUILDING CODE. EXTENT OF THIS PROJECT IS AS FOLLOWS: REPLACE THE 2X6 DECK BOARDS WITH TREX TRANSCEND LINE OF DECKING, IN THE COLOR OF ROPE SWING. NEW DECK JOISTS ARE TO BE INSTALLED AT 24" O.C. ADDING TO THE EXISTING DECK JOISTS ALREADY IN PLACE. JOIST SPACING AFTER NEW JOISTS ARE ADDED TO RESULT IN 12" O.C. SPACING. REPLACE ANY OF THE EXISTING DECK JOISTS AS NEEDED. INSTALL JOIST TAPE ON TOP OF EVERY JOIST. NEW 10" PIERS AND NEW 4X4 POSTS TO BE ADDED UNDER RIM JOIST. NEW POST SPACING TO BE AROUND 3'-3" O.C. EXISTING RAILING TO BE REPLACED WITH RDI METAL POSTS AND RAILING. RDI AVALON RAIL TOP CAP TO BE INSTALLED OVER OVER RAILINGS AND POSTS. THE FIRST SECTION OF RAILING WHICH IS HALF AS TALL AS THE REST IS TO BE REPLACED WITH A COMPARABLE SECTION OF RAILING. RAILING SECTION NEXT TO ENTRY DOOR IS NOT TO BE REPLACE. EXISTING 2X6 DECKING NEXT TO ENTRY DOOR IS NOT TO BE REPLACED. NEW PRESSURE TREATED 4X4 DECK POSTS W/ (2) GALVANIZED ½" LAG BOLTS EACH POST RDI METAL POST 36 " M I N DECK WORK TO BE OVER EXISTING +/ - 4 ' - 6 " +/ - 2 ' - 0 " 475 PIONEER LN PARCEL NUMBER: 3524105004 THIS SECTION OF WALL IS A BUMP-OUT FROM THE LIVING ROOM, THESE ARE THE PRESUMED CONDITIONS, CONTACT ENGINEER WITH QUESTIONS IF OTHER CONDITIONS APPLY RDI AVALON RAILING AND POST CAP 8"4" 3'-3"3'-3" 6'-6" EXISTING COLOR KEY NEW DEMOLITION CONCRETE RAILING THIS SECTION OF RAILING TO BE REPLACED WITH ANOTHER OF SIMILAR SIZE 7 A1 8 A1 26'-0" 10 ' - 6 " 475 PIONEER LN 475 PIONEER LN 475 PIONEER LN STRUCTURAL NOTES Van Horn Engineering Frank Roberts - PE# 39508 Phone 970.586.9388 frank@vanhornengineering.com NEW PRESSURE TREATED DECK JOIST THIS SECTION OF RAILIG AND DECKING NOT TO BE REPLACED +/ - 2 0 " 3' - 2 " 10" ADD (4) SIMPSON DTT1Z TENSION TIES EVENLY SPACED ALONG LEDGER BOARD EXISTING LEDGER BOARD, VERIFY/UPGRADE CONNECTION TO HOUSE W/ (2) 3 5/8" LEDGERLOKS OR 1/2"X4" LAGS @ 8" O.C. Pr o j e c t : H o w a r d D e c k P r o j e c t F i l e : 4 7 5 P i o n e e r L n C D s M o d i fied : M a y 2 2 , 2 0 2 3 P r i n t : M a y 2 2 , 2 0 2 3 D r a w n b y : S M R C h e c k e d b y : F E R Sheet Number A1 Voyager One Design Co. Date Sheet Title New Deck Cover Page and Construction Plan May 22, 2023 of 1 Ho w a r d D e c k P r o j e c t 47 5 P i o n e e r L n Es t e s P a r k , C O 8 0 5 1 7 DA T E RE V I S I O N BY Scale ¼" = 1'-0" 5/22/2023 R312.1.3 Opening limitations. Required guards shall not have openings from the walking surface to the required guard height that allow passage of a sphere 4 inches (102 mm) in diameter. Less than APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 06/06/2023