Loading...
HomeMy WebLinkAboutPLANS New SFD 2311 Larkspur Ave 2021-0121Lark s p u r D r i v e Lot 15 15' drainage & utility easement (typical) 15' drainage & utility easement (typical) 15' drainage & utility easement (typical) edge asphalt edge asphalt ±1' asphalt ENCROACHMENT N 3 9 ° 0 5 ' 1 2 " W 1 8 2 . 4 4 ' N 3 8 ° 5 8 ' 5 6 " E 2 1 4 . 4 7 ' S 5 1 ° 0 4 ' 0 5 " E 1 3 3 . 1 1 ' S 2 0 ° 5 6 ' 4 2 " W 2 3 3 . 9 1 ' O u t L o t " B " L o t 1 8 L o t 1 6 L o t 1 4 S o u t h S t . V r a i n A v e n u e B a s i s o f B e a r i n g s 29 . 0 ' 56.0' 29 . 0 ' 56.0' 97.0' 18.0' 22.0' proposed driveway proposed residence 3 telephone risers & transformer R=40.00' L=42.25' =60°30'46" Ch=40.31' CB=S 81°06'22" W 107.5' Date Date Date Description Description Description REVISIONS 532 West 66th Street, Loveland, CO 80538 PLS Corporation CLIENT Party Chief Print Date Field Date PLS PM ST Office 970.669.2100 - Info@plscorporation.com TITLE PROJECT NO. NOTICE: According to Colorado law you must commence any legal action based upon any defect in this survey within three years after you first discover such defect. In no event, may any action based upon any defect in this survey be commenced more than ten years from the date of the certification shown hereon. October 12, 2020 n/a n/a MBS MBS n/a The GCI Company CARRIAGE HILLS 6TH FILING, Lot 15 Plot Plan Section 1, Township 4 North, Range 73 West, 6th PM, Larimer County, CO 20102.001b Notes: -This is not a Land Survey. -No wetlands determinations were made this date. -Address: 2311 Larkspur Ave Estes Park, CO -Distances shown are in U.S. Survey Feet Legal Description (per assessor): Lot 15, Carriage Hills - 6th Filing, County of Larimer, State of Colorado. 0 60 30 N o r t h - S c a l e 1 " = 3 0 ' 2311 Larkspur Av Estes Park Co 80517 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 01/21/2021 This structure must comply with the requirements of the 2017 National Electrical Code All Irrigation Sprinkler Taps Shall be Protected by an Approved Back Flow Device All architectural plans, engineered foundation plans, soils reports, truss drawings, energy code report or ResCheck must be onsite for inspections. SOFFITS (EAVES) WITHIN 5FT SETBACK SHALL BE PROTECTED WITH FIRE RESISTANT MATERIALS. NO OPENINGS ALLOWED. 11.23.20 Adam Denton, PE Digitally signed by Adam Denton, PE DN: C=US, E=adam@dentonengineeringllc.com, O="Denton Engineering, LLC", OU=Structural Engineer, CN="Adam Denton, PE" Reason: I am the author of this document Date: 2020.11.23 16:34:30-07'00' Reviewed by SAFEbuilt 01/21/2021 11.23.20 R408.2 Openings for under-floor ventilation. The minimum net area of ventilation openings shall be not less than 1 square foot (0.0929 m2) for each 150 square feet (14 m2) of under-floor area. One ventilation opening shall be within 3 feet (915 mm) of each corner of the building. Ventilation openings shall be covered for their height and width with any of the following materials provided that the least dimension of the covering shall not exceed 1/4 inch (6.4 mm): 1. Perforated sheet metal plates not less than 0.070 inch (1.8 mm) thick. 2. Expanded sheet metal plates not less than 0.047 inch (1.2 mm) thick. 3. Cast-iron grill or grating. 4. Extruded load-bearing brick vents. 5. Hardware cloth of 0.035 inch (0.89 mm) wire or heavier. 6. Corrosion-resistant wire mesh, with the least dimension being 1/8 inch (3.2 mm) thick. Exception: The total area of ventilation openings shall be permitted to be reduced to 1/1,500 of the under-floor area where the ground surface is covered with an approved Class I vapor retarder material and the required openings are placed to provide cross ventilation of the space. The installation of operable louvers shall not be prohibited. Reviewed by SAFEbuilt 01/21/2021 R311.3.1 Floor elevations at the required egress doors. Landings or finished floors at the required egress door shall be not more than 11/2 inches (38 mm) lower than the top of the threshold. R311.3.2 Floor elevations for other exterior doors. Doors other than the required egress door shall be provided with landings or floors not more than 73/4 inches (196 mm) below the top of the threshold. Exception: A top landing is not required where a stairway of not more than two risers is located on the exterior side of the door, provided that the door does not swing over the stairway. R311.3.3 Storm and screen doors. Storm and screen doors shall be permitted to swing over exterior stairs and landings. R311.3 Floors and landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall be not less than the door served. Every landing shall have a dimension of not less than 36 inches (914 mm) measured in the direction of travel. The slope at exterior landings shall not exceed 1/4 unit vertical in 12 units horizontal (2 percent).