Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS Solar 1720 Olympian Ln 2020-12-07
SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME RE I N S , B R E N D A 17 2 0 O L Y M P I A N L A N E ES T E S P A R K , C O L O R A D O , 80 5 1 7 (9 7 0 ) 5 8 6 - 1 6 5 7 11/09/2020 FREEDOM SOLAR, LLC Project NameSTREET ADDRESSCITY & STATE PV-0 SCOPE OF WORK SYSTEM RATING GOVERNING CODES COVER SHEET INDEX 2017 NATIONAL ELECTRICAL CODE 2015 INTERNATIONAL RESIDENTIAL CODE UNDERWRITERS LABORATORIES (UL) STANDARDS OSHA 29 CFR 1910.269 TO INSTALL A SOLAR PHOTOVOLTAIC (PV) SYSTEM AT THE REINS RESIDENCE, LOCATED AT 1720 OLYMPIAN LANE, ESTES PARK, COLORADO. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. 7.47 kW DC STC 6.28 kW AC PROJECT LOCATION VICINITY MAP PV-0 COVER PV-1 SITE MAP AND PV LAYOUT PV-2 STRING MAP AND MONITORING LAYOUT PV-3 ELECTRICAL DIAGRAM PV-4 EQ WALL & MOUNTING DETAIL PV-5 SYSTEM LABELING DETAIL PV-6 SAFETY PLAN EQUIPMENT SUMMARY (18)SUNPOWER SPR-A415-G-AC PV MODULES (18)SUNPOWER SPR-A415-G-AC [240V] PV INVERTERS (172) (16 X 10.75') LINEAR FEET SUNPOWER INVISIMOUNT PV Installation Professional Josh Meade Cert #PV-041115-010201 PV ARRAY #1 (10) MODULES PV ARRAY #2 (08) MODULES SUNPOWER INVISIMOUNT RAIL (TYP.) RAFTER (TYP.) ON 24" CENTERS S5! VERSABRACKET ATTACHMENT (TYP.) SUNPOWER PV MODULE (TYP.) DETAIL: TOWN OF ESTES PARK REVENUE METER #23116 GROUNDING ELECTRODE MAIN DISTRIBUTION PANEL SOLAR LOAD CENTER MONITORING PV AC DISCONNECT - VISIBLE BREAK - LOCKABLE - LABELED SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME RE I N S , B R E N D A 17 2 0 O L Y M P I A N L A N E ES T E S P A R K , C O L O R A D O , 80 5 1 7 (9 7 0 ) 5 8 6 - 1 6 5 7 11/09/2020 FREEDOM SOLAR, LLC PV-1 SITE MAP & PV LAYOUT CONSTRUCTION NOTES 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4.) TYP. ROOF ATTACHMENT SPACING SHALL BE 6'-0" MAX FOR LAG BOLT TYPE ROOF ATTACHMENTS ANCHORED TO RAFTERS 5.) TYP. ROOF ATTACHMENT SPACING SHALL BE 4'-6" MAX FOR S-5! CLAMPS ANCHORED TO STANDING SEAM ROOF PANELS 33714LEAD ID: CONSTRUCTION SUMMARY (18)(SUNPOWER SPR-A415-G-AC) SOLAR MODULES, 7.47 kW DC STC MODULE DIMENSIONS = 40.0" X 72.2" X 1.57" (18)SUNPOWER SPR-A415-G-AC [240V] PV INVERTERS COMBINED INVERTER OUTPUT = 6.28 kW AC. (172) (16 X 10.75') LINEAR FEET SUNPOWER INVISIMOUNT (72)S5! Versabracket ROOF ATTACHMENTS SITE DETAILS ROOF TYPE: STANDING SEAM METAL ARRAY #1 - TILT = 45°, AZIMUTH = 167° ARRAY #2 - TILT = 18°, AZIMUTH = 167° INSTALLATION DIFFICULTY = 8 => NORMAL (1)SUNPOWER MONITORING S-5 VERSABRACKETS SHALL BE SPACED NO MORE THAN 2' APART ALONG THE LENGTH OF THE RAIL, AND 1' APART FOR THE AREAS CLOSE TO THE EDGE OF THE ROOF. PV-2 STRING MAP & MONITORING LAYOUT SUNPOWER SUPERVISOR S/N____________________________ SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME RE I N S , B R E N D A 17 2 0 O L Y M P I A N L A N E ES T E S P A R K , C O L O R A D O , 80 5 1 7 (9 7 0 ) 5 8 6 - 1 6 5 7 11/09/2020 FREEDOM SOLAR, LLC (4) AWG #10 THWN-2 (1) AWG #8 THWN-2 GND IN 3/4" CONDUIT SUNPOWER MONITORING 20A 20A 20A JUNCTION BOXES: TRANSITION FROM DG CABLE TO AWG #10 THWN-2 NEMA 3R, UL LISTED SOLAR LOAD CENTER 240VAC, 125A NEMA 3R, UL LISTED (3) 2P-20A BREAKERS 08 MODULES 10 MODULES 600V FOUR WIRE DIRECT BURIAL CABLE IF CT CONDUCTORS ARE EXTENDED PRODUCTION CT ON L1 (3) AWG #6 THWN-2 (1) AWG #8 THWN-2 GND IN 1" CONDUIT BRANCH #1 BRANCH #2 EXISTING GROUNDING ELECTRODE SYSTEM MAIN SERVICE DISCONNECT 240V, 200A200A M POINT OF INTERCONNECTION (1) 2P-40A CIRCUIT BREAKER INSTALLED AT OPPOSITE END OF BUS FROM MAIN DISCONNECT 40A PV AC DISCONNECT 240VAC, 60A NON-FUSIBLE, NEMA 3R, UL LISTED CONSUMPTION CTS ON L1 & L2 MAIN DISTRIBUTION PANEL SQD-HOME LINE METER MAIN 1P3W 240V, 200A BUS SOLAR ARRAY -7.47 kW DC STC (18) (SUNPOWER SPR-A415-G-AC) MODULES (18) (SUNPOWER SPR-A415-G-AC) INVERTERS 240VAC, 1.45A MAX CEC WEIGHTED EFFICIENCY 97.0% NEMA 4R, UL LISTED, INTERNAL GFDI TOWN OF ESTES PARK REVENUE METER #23116 1-PHASE, 240V SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME RE I N S , B R E N D A 17 2 0 O L Y M P I A N L A N E ES T E S P A R K , C O L O R A D O , 80 5 1 7 (9 7 0 ) 5 8 6 - 1 6 5 7 11/09/2020 FREEDOM SOLAR, LLC ELECTRICAL NOTES PV-3 ELECTRICAL DIAGRAM 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90°C WET ENVIRONMENT UNLESS OTHERWISE NOTED. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MAXIMUM MOUNTING HEIGHT FROM GRADE TO CENTER OF METER SOCKET SHALL BE 72" FOR RESIDENTIAL SINGLE PHASE METER SOCKETS 0-320 AMPS. MINIMUM MOUNTING HEIGHT IS 30" FROM FOR AUSTIN ENERGY, AND 48" FOR ALL OTHER JURISDICTIONS 9.) MINIMUM HORIZONTAL CLEARANCE FROM GAS REGULATOR TO ANY ELECTRICAL ENCLOSURE IS 36", EXCEPT AUSTIN ENERGY WHICH REQUIRES 48" CLEARANCE FROM GAS TO METER SOCKET 10.) PV DISCONNECT SHALL BE VISIBLE, LOCKABLE AND LABELED AND THE DOOR CANNOT BE OPENED WHEN HANDLE IS IN ON POSITION 11.) BY DEFAULT THE MONITORING DEVICE IS SHOWN CONNECTED TO A 20-AMP BREAKER IN THE SOLAR LOAD CENTER. ALTERNATIVELY, THE MONITORING DEVICE MAY BE CONNECTED TO A 20-AMP BREAKER AT THE MAIN DISTRIBUTION PANEL. CALCULATIONS FOR CURRENT CARRYING CONDUCTORS CALCULATIONS FOR OVERCURRENT DEVICES INVERTER OUTPUT WIRE AMPACITY CALCULATION [NEC 690.8(A)(3)]: 1.45A PER INVERTER (SUNPOWER SPR-A415-G-AC [240V]) MAXIMUM INVERTER BRANCH CURRENT = (11)(1.45A) = 16.0A CONTINUOUS USE: #10 WIRE 75°C DERATED AMPACITY = (0.80)(35.0A) = 28.0A 28.0A > 16.0A CONDITIONS OF USE: #10 WIRE 90°C DERATED AMPACITY = (0.91)(0.70)(40.0A) = 25.5A 25.5A > 16.0A SOLAR LOAD CENTER OUTPUT WIRE AMPACITY CALCULATION [NEC 690.8(A)(3)]: 1.45A PER INVERTER (SUNPOWER SPR-A415-G-AC [240V]) COMBINED CURRENT = (18)(1.45A) = 26.1A #6 WIRE 75°C DERATED AMPACITY = (0.80)(65A) = 52.0A 52.0 > 26.1A CONDITIONS OF USE: #6 WIRE 90°C DERATED AMPACITY = (0.91)(75A) = 68.3A 68.3A > 26.1A INVERTER BRANCH AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.45A PER INVERTER (SUNPOWER SPR-A415-G-AC [240V]) MAXIMUM BRANCH INVERTER CURRENT = (11)(1.45A) = 16.0A MINIMUM OCPD = (16.0A)(1.25) = 20A USE 2P-20A BREAKERS IN SOLAR LOAD CENTER FOR INVERTER BRANCH OCPD SYSTEM AC CURRENT CALCULATION [NEC 690.8(A)(3)]: 1.45A PER INVERTER (SUNPOWER SPR-A415-G-AC [240V]) COMBINED CURRENT = (18)(1.45A) = 26.1A MINIMUM OCPD = (26.1A)(1.25) = 32.6A USE 2P-40A BREAKER IN MDP FOR SYSTEM OCPD PV-4 EQ.WALL & MOUNTING DETAIL EQUIPMENT ELEVATION 1NTS MOUNTING DETAIL 3NTS MOUNTING METHOD 2NTS SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME RE I N S , B R E N D A 17 2 0 O L Y M P I A N L A N E ES T E S P A R K , C O L O R A D O , 80 5 1 7 (9 7 0 ) 5 8 6 - 1 6 5 7 11/09/2020 FREEDOM SOLAR, LLC MAIN DISTRIBUTION PANEL POINT OF INTERCONNECTION -OUTSIDE HOUSE TOWN OF ESTES PARK REVENUE METER PV AC DISCONNECT SOLAR LOAD CENTER MONITORING FROM PV ARRAY 61.3 In 4.50 in 123.50 in RAFTERS @ 2 4 " O . C . T Y P . STANDIN G M E T A L S E A M R O O F SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME RE I N S , B R E N D A 17 2 0 O L Y M P I A N L A N E ES T E S P A R K , C O L O R A D O , 80 5 1 7 (9 7 0 ) 5 8 6 - 1 6 5 7 11/09/2020 FREEDOM SOLAR, LLC > RED BACKGROUND > WHITE LETTERING > MIN. 3/8" LETTER HEIGHT > ALL CAPITAL LETTERS > ARIAL OR SIMILAR FONT > REFLECTIVE, WEATHER RESISTANT MATERIAL, UL 969 SIGNAGE REQUIREMENTSNOTE: NOT ALL LABELS MAY BE APPLICABLE WARNING: PHOTOVOLTAIC POWER SOURCE REQ'D BY: NEC 690.13(B)B REQ' BY: AHJ E REQ'D BY: AHJ APPLY TO: REVENUE METER SOCKET (IF APPLICABLE) G 2" ADDRESS NUMBERS REQ'D BY: NEC 705.12(B)(2)(3)(b)D WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. REQ'D BY: NEC 690.13(B) APPLY TO: PV DISCONNECT APPLY TO: REVENUE METER SOCKET (IF APPLICABLE) WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE APPLY TO: DISTRIBUTION EQUIPMENT ADJACENT TO BACK-FED BREAKER A APPLY TO: PV DISCONNECT REVENUE METER REQ'D BY: FREEDOM SOLAR H APPLY TO: MONITORING DEVICE ENCLOSURE MONITORING APPLY TO: PV DISCONNECT IREQ'D BY: 690.56(1)(a) PV SYSTEM DISCONNECT APPLY TO: RACEWAYS, CABLE TRAYS, OTHER WIRING METHODS, AND ENCLOSURES THAN CONTAIN PV SYSTEM DC CONDUCTORS REQ'D BY: NEC 690.31(G)(3)C PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT: 26.1A OPERATING VOLTAGE: 240 VAC APPLY TO: MAIN DISTRIBUTION PANEL JREQ'D BY: FREEDOM SOLAR SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS REQ'D BY: AHJ F APPLY TO: PV METER SOCKET (IF APPLICABLE) PV METER PV-5 SYSTEM LABELING DETAIL D R I V E W A Y SHEET NUMBER DESIGN BY: ADESIGN PACKET REVDATE REVISIONS DESCRIPTION CONTRACTOR FREEDOM SOLAR LLC 4801 FREIDRICH LN, STE 100 AUSTIN, TX 78744 TECL # 28621 TBPE FIRM # F-17690 PROJECT NAME SHEET SIZE ANSI B 11" x 17" SHEET NAME RE I N S , B R E N D A 17 2 0 O L Y M P I A N L A N E ES T E S P A R K , C O L O R A D O , 80 5 1 7 (9 7 0 ) 5 8 6 - 1 6 5 7 11/09/2020 FREEDOM SOLAR, LLC PV-6 SAFETY PLAN DRAW IN CONTROLLED ACCESS ZONE (CAZ) BOUNDARY AND LADDER PLACEMENT ON SITE PLAN BELOW. HARD HAT IS REQUIRED AT ALL TIMES IN CAZ CONDUCT SAFETY MEETING WITH ALL CREW MEMBERS ON SITE AT THE BEGINNING OF EACH JOB. USE SIGN IN SHEET BELOW. 1. _________________________________________ 2. _________________________________________ 3. _________________________________________ 4. _________________________________________ 5. _________________________________________ GUEST SIGN IN 1. _________________________________________ 2. _________________________________________ 3. _________________________________________COMPETENT PERSON: ___________________________ JOB START DATE: _________________ Datasheet 400–425 W Residential AC Module SunPower® Maxeon® Technology Built specifically for use with the SunPower Equinox™ system, the only fully integrated solution designed, engineered and warranted by one manufacturer. Highest Power Density Available. SunPower’s new Maxeon® Gen 5 cell is 65% larger than prior generations, delivering the most powerful cell and highest-efficiency panel in residential solar. The result is more power per square meter than any commercially available solar. Highest Lifetime Energy and Savings. Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.1 Best Reliability. Best Warranty. With more than 25 million modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. And Better. SunPower® Maxeon® Technology •Most powerful cell in home solar 2 •Delivers unmatched reliability 3 •Patented solid metal foundation prevents breakage and corrosion Factory-integrated Microinverter (MI) •Highest-power integrated AC module in solar •60% lighter than prior SunPower MIs •Engineered and calibrated by SunPower for SunPower AC modules sunpower.com A-Series: A425 | A415 | A400 SunPower® Residential AC Module AC Electrical Data IInverterr Model: SSPWR--AA4 @240 VAC Peak Output Power 366 VA Max. Continuous Output Power 349 VA Nom. (L–L) Voltage/Range2 (V) 240 / 211–264 Max. Continuous Output Current (A) 1.45 Max. Units per 20 A (L–L) Branch Circuit3 11 CEC Weighted Efficiency 97.0% Nom. Frequency 60 Hz Extended Frequency Range 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 5.8 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor (adjustable) 0.7 lead. / 0.7 lag. 1 SunPower 415 W, 22.2% efficient, compared to a Conventional Panel on same-sized arrays (260 W, 16% efficient, approx. 1.6 m²), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.” PVSC 2018). 2 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of January 2019. 3 #1 rank in “Fraunhofer PV Durability Initiative for Solar Modules: Part 3.” PVTech Power Magazine, 2015. Campeau, Z. et al. “SunPower Module Degradation Rate,” SunPower white paper, 2013. 4 Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide #518101 for more information. 5 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. See www.sunpower.com/facts for more reference information. For more details, see extended datasheet www.sunpower.com/datasheets Specifications included in this datasheet are subject to change without notice. ©2019 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo and MAXEON are registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. Please read the Safety and Installation Instructions 532628 for additional details. 532618 RevA Tested Operating Conditions Operating Temp. ȫr)WRr)ȫr&WR°C) Max. Ambient Temp. 122°F (50°C) Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m² front & back Snow: 125 psf, 6000 Pa, 611 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 66 Monocrystalline Maxeon Gen 5 Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 46.5 lbs (21.1 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1703 • UL 1741 / IEEE-1547 • UL 1741 AC Module (Type 2 fire rated) • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA) 4 (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment 6 Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with InvisiMount racking and InvisiMount accessories (UL 2703): • Module grounding and bonding through InvisiMount • Class A fire rated When used with AC module Q Cables and accessories (UL 6703 and UL 2238)6 : • Rated for load break disconnect PID Test Potential-induced degradation free DC Power Data SPR-A425-G-AC SPR-A415-G-AC SPR-A400-G-AC Nom. Power 5 (Pnom) 425 W 415 W 400 W Power Tol. +5/í0% +5/í0% +5/í0% Module Efficiency 22.8 22.3 21.5 Temp. Coef. (Power) í0.29%/°C Shade Tol. Integrated module-level max. power point tracking Improve Support, Reduce Maintenance Costs An intuitive monitoring website enables you to: • See a visual map of customer sites • Remotely manage hundreds of sites • Receive elective system reports • Locate system issues and remotely diagnose • Diagnose issues online • Drill down for the status of individual devices Add Value for Customers With the SunPower Monitoring System customers can: • See what their solar system produces each day, month, or year • Optimize their solar investment and save on energy expenses • See their energy use and estimated bill savings • See their solar system’s performance using the SunPower monitoring website or mobile app SunPower EnergyLink—Plug-and-Play Installation This complete solution for residential and commercial monitoring and control includes the SunPower® PV Supervisor 6 (PVS6) which improves the installation process, overall system reliability, and customer experience. • Compact footprint for improved aesthetics • Robust cloud connectivity and comprehensive local connectivity • Flexible configuration of devices during installation • Consumption metering • Revenue-grade production metering (pending) • Web-based commissioning • Remote diagnostics of PVS6 and inverters • Durable UL Type 3R enclosure reduces maintenance costs • Easy integration with SunPower eBOS Robust Cloud Connectivity Multiple options to maintain optimal connectivity: •Hardwired Ethernet •Wi-Fi • Cellular backup SunPower Monitoring Websites PVS6 SunPower AC Modules Multiple communication options include Ethernet, Wi-Fi, and cellular. 530536 RevC SunPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates consistent, even module spacing • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs ȏ 'HVLJQLQODQGVFDSHDQGSRUWUDLWZLWKXSWRɒ rail span • Pre-drilled rails and rail splice • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics ȏ 3UHPLXPORZSURȴOHGHVLJQ • Black anodized components ȏ +LGGHQPLGFODPSVDQGFDSSHGȵXVK end clamps Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Optional URRIWRSWUDQVLWLRQȵDVKLQJUDLO mounted J-box, and wire management rail clips • Combine with SunPower modules and SunPower EnergyLink® monitoring app sunpower.com Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster LQVWDOODWLRQWLPHGHVLJQȵH[LELOLW\DQGVXSHULRUDHVWKHWLFV 7KHΖQYLVL0RXQWSURGXFWZDVVSHFLȴFDOO\HQYLVLRQHGDQG engineered to pair with SunPower modules. The resulting V\VWHPOHYHODSSURDFKDPSOLȴHVWKHDHVWKHWLFDQG LQVWDOODWLRQEHQHȴWVȃIRUKRPHRZQHUVDQGIRULQVWDOOHUV Datasheet SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Mid clamp Black oxide stainless steel 300 series 63 g (2.2 oz) End clamp Black anodized aluminum 6000 series 110 g (3.88 oz) Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) Rail splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) Rail bolt M10-1.5 × 25 mm; custom T-head SS304 18 g (0.63 oz) Rail nut M10-1.5; DIN 6923 SS304 nominal Ground lug assembly SS304; A2-70 bolt; tin-plated copper lug 106.5 g (3.75 oz) Row-to-row grounding clip SS 301 with SS 304 M6 bolts 75 g (2.6 oz) Row-to-row spacer Black POM-grade plastic 5 g (0.18 oz) Roof Attachment Hardware Supported by Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal interface for other roof attachments InvisiMount Operating Conditions Temperature ȫr&WRr&ȫr)WRr) Max. Load (LRFD)• 3000 Pa uplift • 6000 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation. ΖQYLVL0RXQW:DUUDQWLHV$QG&HUWLȴFDWLRQV Warranties • 25-year product warranty • \HDUȴQLVKZDUUDQW\ &HUWLȴFDWLRQV • UL 2703 Listed • Class A Fire Rated © 2018 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. $OORWKHUWUDGHPDUNVDUHWKHSURSHUW\RIWKHLUUHVSHFWLYHRZQHUV6SHFLȴFDWLRQVLQFOXGHGLQWKLVGDWDVKHHWDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH InvisiMount Components Module¹ / Mid Clamp and Rail Mid Clamp End Clamp Rail and Rail Splice Ground Lug Assembly Module¹ / End Clamp and Rail sunpower.com 509506 RevF ² SunPower recommends that all Equinox™, InvisiMount™, and AC module systems always be designed using the InvisiMount Span Tables #524734. If a designer decides to instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed Professional Engineer (PE) must then stamp all calculations. If you have any questions please contact SunPower Technical Support at 1-855-977-7867. InvisiMount Component LRFD Capacities² Mid clamp Uplift 664 lbf Shear 540 lbf End clamp Uplift 899 lbf Shear 220 lbf Rail Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft Rail splice Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft L-foot Uplift 1000 lbf Shear 390 lbf Datasheet ¹ Module frame that is compatible with the InvisiMount system required for hardware interoperability. Row-to-Row Spacer Row-to-Row Grounding Clip SHHDWRQFRP (DWRQJHQHUDOGXW\FDUWULGJH IXVHVDIHW\VZLWFK '*15% 83& 'LPHQVLRQV +HLJKW,1● /HQJWK,1● :LGWK,1● :HLJKW/% 1RWHV0D[LPXPKSUDWLQJVDSSO\RQO\ZKHQGXDO HOHPHQWIXVHVDUHXVHG3KDVHKSUDWLQJVKRZQLV DJURXQGHG%SKDVHUDWLQJ8/OLVWHG :DUUDQWLHV (DWRQ6HOOLQJ3ROLF\RQH\HDUIURP WKHGDWHRILQVWDOODWLRQRIWKH3URGXFWRU HLJKWHHQPRQWKVIURPWKHGDWHRIVKLSPHQW RIWKH3URGXFWZKLFKHYHURFFXUVILUVW ● 6SHFLILFDWLRQV 7\SH*HQHUDOGXW\FDUWULGJHIXVHG● $PSHUDJH5DWLQJ$● (QFORVXUH1(0$5● (QFORVXUH0DWHULDO3DLQWHGJDOYDQL]HGVWHHO● )XVH&ODVV3URYLVLRQ&ODVV+IXVHV● )XVH&RQILJXUDWLRQ)XVLEOHZLWKQHXWUDO● 1XPEHU2I3ROHV7ZRSROH● 1XPEHU2I:LUHV7KUHHZLUH● 3URGXFW&DWHJRU\*HQHUDOGXW\VDIHW\VZLWFK● 9ROWDJH5DWLQJ9● 6XSSRUWLQJGRFXPHQWV (DWRQV9ROXPH&RPPHUFLDO'LVWULEXWLRQ● (DWRQ6SHFLILFDWLRQ6KHHW'*15%● &HUWLILFDWLRQV 8//LVWHG● 3URGXFWFRPSOLDQFH1R'DWD SHHDWRQFRP (DWRQJHQHUDOGXW\QRQIXVLEOH VDIHW\VZLWFK '*85% 83& 'LPHQVLRQV +HLJKW,1● /HQJWK,1● :LGWK,1● :HLJKW/% 1RWHV:$51,1*6ZLWFKLVQRWDSSURYHGIRU VHUYLFHHQWUDQFHXQOHVVDQHXWUDONLWLVLQVWDOOHG :DUUDQWLHV (DWRQ6HOOLQJ3ROLF\RQH\HDUIURP WKHGDWHRILQVWDOODWLRQRIWKH3URGXFWRU HLJKWHHQPRQWKVIURPWKHGDWHRIVKLSPHQW RIWKH3URGXFWZKLFKHYHURFFXUVILUVW ● 6SHFLILFDWLRQV 7\SH1RQIXVLEOHVLQJOHWKURZ● $PSHUDJH5DWLQJ$● (QFORVXUH1(0$55DLQSURRI● (QFORVXUH0DWHULDO3DLQWHGJDOYDQL]HGVWHHO● )XVH&RQILJXUDWLRQ1RQIXVLEOH● 1XPEHU2I3ROHV7ZRSROH● 1XPEHU2I:LUHV7ZRZLUH● 3URGXFW&DWHJRU\*HQHUDOGXW\VDIHW\VZLWFK● 9ROWDJH5DWLQJ9● 6XSSRUWLQJGRFXPHQWV (DWRQV9ROXPH&RPPHUFLDO'LVWULEXWLRQ● (DWRQ6SHFLILFDWLRQ6KHHW'*85%● &HUWLILFDWLRQV 8//LVWHG● 3URGXFWFRPSOLDQFH1R'DWD SHHDWRQFRP (DWRQ&+PDLQOXJORDGFHQWHU &+/53 83& 'LPHQVLRQV +HLJKW,1● /HQJWK,1● :LGWK,1● :HLJKW/% 1RWHV*URXQGEDUNLWVSULFHGVHSDUDWHO\6XLWDEOH IRUXVHDVVHUYLFHHTXLSPHQWZKHQQRWPRUHWKDQ WZRVHUYLFHGLVFRQQHFWLQJPDLQVDUHSURYLGHGRU ZKHQQRWXVHGDVDOLJKWLQJDQGDSSOLDQFH SDQHOERDUG :DUUDQWLHV /LPLWHGOLIHWLPH● 6SHFLILFDWLRQV 6SHFLDO)HDWXUHV&RYHULQFOXGHG● 7\SH0DLQOXJRQO\● $PSHUDJH5DWLQJ$● %R[6L]HU● %XV0DWHULDO&RSSHU● (QFORVXUH1(0$5● (QFORVXUH0DWHULDO0HWDOOLF● )HHG7\SH2YHUKHDG● 0DLQ&LUFXLW%UHDNHU&+● 1XPEHU2I&LUFXLWV● 1XPEHU2I:LUHV7KUHHZLUH● 3KDVH6LQJOHSKDVH● 9ROWDJH5DWLQJ9<9● :LUH6L]H$:*● 6XSSRUWLQJGRFXPHQWV 7\SH&+&LUFXLW%UHDNHUVDQG/RDGFHQWHUV● /RDGFHQWHUVDQG&LUFXLW%UHDNHUV● (DWRQV9ROXPH5HVLGHQWLDODQG/LJKW &RPPHUFLDO ● SHHDWRQFRP (DWRQ&+PDLQOXJORDGFHQWHU &+/5 83& 'LPHQVLRQV +HLJKW,1● /HQJWK,1● :LGWK,1● :HLJKW/% 1RWHV6XLWDEOHIRUXVHDVVHUYLFHHTXLSPHQWZKHQ QRWPRUHWKDQVL[VHUYLFHGLVFRQQHFWLQJPDLQVDUH SURYLGHGRUZKHQQRWXVHGDVDOLJKWLQJDQG DSSOLDQFHSDQHOERDUG5DLQSURRISDQHOVDUH IXUQLVKHGZLWKKXEFORVXUHSODWHV)RUUDLQSURRI KXEV :DUUDQWLHV /LPLWHGOLIHWLPH● 6SHFLILFDWLRQV 6SHFLDO)HDWXUHV&RYHULQFOXGHG● 7\SH0DLQOXJRQO\● $PSHUDJH5DWLQJ$● %R[6L]H%● %XV0DWHULDO&RSSHU● (QFORVXUH1(0$5● (QFORVXUH0DWHULDO0HWDOOLF● )HHG7\SH2YHUKHDG● 0DLQ&LUFXLW%UHDNHU&+● 1XPEHU2I&LUFXLWV● 1XPEHU2I:LUHV7KUHHZLUH● 3KDVH6LQJOHSKDVH● 9ROWDJH5DWLQJ9● :LUH6L]H$:*● 6XSSRUWLQJGRFXPHQWV 'LPHQVLRQDO'UDZLQJ&+/2$'&(17(5 0$,1/8*21/<287'2251(0$5 9$&3+ ● -XQFWLRQ%R[[[ 'UDZQ%\20'DWH *DVNHW7RS9LHZ *DVNHW6LGH9LHZ /LG7RS9LHZ /LG6LGH9LHZ %R[7RS9LHZ %R[6LGH9LHZ 5 5 E\ 8//LVWHG 0DULQH/LVWHG 8/)LOH(4&83 8/&RQWURO&0 0DWHULDOLV5LJLG39& FXLQ9ROXPHFXFP 6FUHZVDUH=LQF3ODWHG6WHHO *DVNHWLVQHRSUHQH