PLANS Commercial Remodel 203 Cleave St 2023-03-27
BEE 203 BUILDING REMODEL 203 Cleave Street Estes Park, CO 80517 Revision 1 - 3/23/23 ©2023 Interstice Architectural Studio, LLC Architectural Site Plan Scale: 1/8" = 1'-0"north 0 2 4 8 12 16 General Notes 1. Refer to Permit Information and Project Narrative on Sheet A2. 2. Do not scale drawings for dimensions. Dimensions this project are typically to face of existing finishes and face of new framing member, unless otherwise noted. 3. Clean-up of rubbish and debris resulting from work shall be collected regularly from project site and legally disposed of. 4. Contractor to verify existing conditions and review discrepancies or inconsistencies of site and drawings with Architect prior to commencing construction. Contractors are responsible for all materials and quantities shown in these drawings graphically as well as those called for by note. The Contractor shall obtain all necessary permits to complete the proposed work and shall comply with all local, state, and federal regulations. 5. All materials and construction shall be completed in accordance with the requirements of Town of Estes Park and the 2015 IBC. 6. Interior finishes must conform to the governing code for Class B flame spread and smoke development. Refer to "Permit Information" Item B,4 on Sheet A2 7. NFPA 13R automatic sprinkler system and an automatic fire alarm system are required for this project. These systems shall be extended throughout both levels of the entire building. Manual pull stations are not required. Fire sprinkler drawings are to be prepared by the Fire Protection Contractor as a deferred submittal. They are to be reviewed by the Architect and then submitted for approval to the Division of Building Safety and the Fire Department. 8. Provide blocking in all walls as required for door stops, cabinetry, selving, grab bars and other toilet accessories – verify locations with Architect prior to drywall installation. A1 Title Sheet and Architectural Site Plan CIVIL 1 of 1 Existing Conditions Site Plan ARCHITECTURAL A2 Permit Information A3 Lower Level Demolition Plan A4 Upper Level Demolition Plan A5 Lower Level New Construction Plan A6 Upper Level New Construction Plan A7 Roof Plan A8 Exterior Elevations A9 Exterior Elevations A10 Building Sections A11 Openings and Details A12 Stair Section STRUCTURAL S1 Foundation and Framing Plan S2 Structural Details PLUMBING P0 Plumbing Specification P1 Plumbing Schedule and Notes P2 Plumbing Diagrams P3 Plumbing Plans ELECTRICAL E1 Electrical Site Plan and One-Line Diagram E2 Electrical Power and Lighting Plans Sheet Index Electronic Documents Documents and Resources are available on the project web site… http://www.intersticearch.com/bee/ Color Legend In these drawings colors represent... Demolition New Construction Cleave St Horn B i g Dr L a w n L n W Elkhorn Ave Weist Dr E Elkhorn A v e Bond Park Town Hall Vi r g i n i a D r M a c G r e g o r A v e Park L n Spru c e D r Mo r a i n e A v e Riv e r s i d e D r Rockwell St Ivy St W Elkhorn Ave Downtown BEE Project 203 Cleave St Vicinity Map Estes Park, Colorado Not to Scale north OWNER Ms. Barbara Marshall BAT223, LLC PO Box 3223, Estes Park, CO 80517 PARTNER /Mr. Nick Smith TENANT Lumpy Ridge Brewing Company 531 S Saint Vrain Ave., Estes Park, CO 80517 (812) 201-3836 smithn62433@yahoo.com ARCHITECT Joseph E Calvin, AIA Interstice Architectural Studio, LLC PO Box 1555, Estes Park, CO 80517 (970) 420-8264 joe@intersticearch.com STRUCTURAL &Dave Bangs, PE CIVIL ENGINEER Victoria Waters, Structural Trail Ridge Consulting Engineers, LLC 1191 Woodstock Ave, Estes Park, CO 80517 (970) 308-8221 dbangs@trailridgece.com PLUMBING Vance Richardson DESIGN VORtech Services LLC (970) 691-3134 v3033@comcast.net GENERAL Charles Santagati CONTRACTOR Glacier Creek Construction, Inc. 1191 Graves Ave, Estes Park, CO 80517 (970) 586-1685 glaciercreekinc@gmail.com Project Team E E E Truck connect rec. 50 amp mount in new pedestal - re: Elec Existing Building Cleave Street Electrical Service - See Sheet E1 New stairway and railing - re: Sheets A12 & S1 Property Line Remove existing propane tank and line to building Property Lines New stone steps - see Sheet A6 Re v i s i o n 1 - 3 / 2 3 / 2 3 3/23/23 Sheet NumberA1 Joseph E Calvin Date Sheet Title Title Sheet and Architectural Site Plan March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 1191 WOODSTOCK DRIVE, ESTES PARK, CO 80517 www.trailridgece.com * 970-308-8221 * dbangs@trailridgece.com © 2023 DAB ELEC/TELEPHONE METER/CONNECTION 10' SCALE: 1" = 10' 0 20' EXISTING CONDITIONS - SITE PLAN 203 CLEAVE STREET OWNER WHIMSICAL INC PO BOX 3223 ESTES PARK, CO 80517 ENGINEER/CONTACT PERSON TRAIL RIDGE CONSULTING ENGINEERS, LLC 1191 WOODSTOCK DRIVE ESTES PARK, CO 80517 ZONING INFORMATION SUBJECT PROPERTY ZONING CLASSIFICATION: CD - COMMERCIAL DOWNTOWN SURROUNDING PROPERTY ZONING CLASSIFICATION: CD - COMMERCIAL DOWNTOWN BUILDING SETBACK: FRONT: MIN=8'; MAX 16' REAR: 10' IF IT ABUTS A RESIDENTIAL PROPERTY; 0' FOR ALL OTHER CASES SIDE: 10' IF IT ABUTS A RESIDENTIAL PROPERTY; 0' FOR ALL OTHER CASES GENERAL NOTES 1. THIS SITE PLAN IS REPRESENTATIONAL ONLY AND IS NOT TO BE INTERPRETED AS A BOUNDARY SURVEY NOR IMPROVEMENT SURVEY. 2. PLATTED BEARINGS WERE ROTATED 0°14"57 CLOCKWISE TO MATCH GEODETIC BEARINGS MEASURED BETWEEN THE TWO FOUND MONUMENTS AS SHOWN HEREON. BEARINGS FOR THIS SITE PLAN ARE BASED ON THESE TWO MONUMENTS, CALCULATED TO BEAR S00°14'57"W. 3. ONLY VISIBLE SURFACE UTILITIES ARE SHOWN HEREON. TRAIL RIDGE CONSULTING ENGINEERS DID NOT CALL FOR UNDERGROUND UTILITY LOCATES PRIOR TO THE FIELD SURVEY AND DOES NOT WARRANT THE LOCATIONS OF THE UTILITIES AS SHOWN HEREON. THAT RESPONSIBILITY LIES WITH THE OWNER/CONTRACTOR. 5. CONTOURS SHOWN HEREON ARE AT 1FT INTERNAL AND ARE BASED UPON FIELD OBSERVATIONS IN JANUARY 2023. LEGAL DESCRIPTION (PER QUIT CLAIM DEED LOCATED LARIMER COUNTY RECEPTION #) LOTS 16, 17, AND THE EAST 6'4" OF LOT 18, BLOCK 8, EXCEPT THE NORTH 30 FEET THEREOF, TOWN OF ESTES PARK Permit Information APPLICABLE CODES 2015 International Building Code 2015 International Mechanical Code 2015 International Fire Code 2015 International Plumbing Code 2015 International Existing Building Code 2020 National Electric Code 2009 ICC/ANSI A117.1 Accessible and Useable Buildings and Facilities A. OCCUPANCY CLASSIFICATION 1. Occupancy Groups and Separations a. Both Levels Together Group R2 Live/Work Unit c. Separation No new fire rated construction 2. Building Areas, Uses and Occupant Load Occupant Occupant a. Lower Level Use Area Load Factor Load i. Tap Room Group B (as part of Group R2 Live/Work Unit) 1) Staff Areas behind Bar 240 sf 200 2 2) Concentrated Patrons at Bar 52 sf 7 8 3)Seating Area 175 sf 15 19 4) Subtotal Tap Room 467 sf 29 ii. Restrooms Accessory 139 sf iii Mechanical Accessory 54 sf . iv. Lower Level Total 660 sf 29 v.Exterior Terrace _690 sf __15_ 46 vi Occupant Load Served by Restrooms 75 b. Upper Level i.Residence Group R3 1040 sf 200 6 c.Total Building Area & Occupant Loa d 1700 sf 35 d. Exterior Decks (not included in above totals) 18 sf 3. Special Requirements based on Occupancy a. Live/Work Units (Section 508.5) i. Floor Area Limited to 3000 sf ✔ ii. Non-Residential Use limited to max 50% of area ✔ iii. Non-Residential Use limited to Lower Level only ✔ iv. Not more than (5) Non-Residential Workers/Employees ✔ B. CONSTRUCTION TYPE 1. Construction Type Type V-B 2. Assembly Requirements (IBC Tables 601 & 602) a. Primary Structural Frame Non-rated b. Exterior Bearing and Nonbearing Walls (705.5) i. West Wall (<5' to property) 1-hr ii. Other Walls Non-rated c. Interior Bearing Walls and Partitions Non-rated f. Floor Construction Non-rated g. Roof Construction Non-rated 3. Opening Protection (Table 705.8) a. West Wall (<5' to property) Not Permitted in new construction - (5) existing windows ((1) egress) to remain 4. Interior Finishes (Chapter 8) a. Classification (all spaces this project) Class C b. Maximum Flame Spread 200 c. Maximum Smoke Development 450 C. ALLOWABLE HEIGHT AND FLOOR AREA 1. Allowable Height (Table 504.3) 60'-0" > actual 19'-8"± 2. Allowable Number of Stories (Table 504.4) a. Group R2 3 > actual 2 stories 3. Allowable Floor Area (Table 506.2) a. Group R2 3000 sf per item A,1,3,a,i b. Frontage Increase Not Taken c. Total Allowable Area 3000 sf/story > actual 1040 sf D. FIRE PROTECTION SYSTEMS 1. Automatic Fire Sprinkler System a. Group R2 NFPA 13R Required 2. Standpipe System Not Required 3. Portable Fire Extinguishers Required 4. Fire Alarm, Detection and Monitoring Required E. EGRESS 1. Emergency Escape and Rescue a. Sleeping rooms require a means of egress directly to the exterior Existing windows meet this requirement 2. Exit signs Not Required within a dwelling unit 3. Emergency Lighting Not Required within a dwelling unit 4. Travel Distance (Table 1017.2) 250' max > 60'-0" actual F. EXISTING BUILDING CODE 1. Classification “Alternation Level 2” 2. Work Area 660 sf on Lower Level 3. Alteration Level 1 Requirements (IEBC Chapter 7) also apply to Level 2 a. No significant requirements or exceptions 4. Alteration Level 2 Requirements (IEBC Chapter 8) a. Sprinkler not required for Alteration Level 2, but see item F,5,a below b. Fire Alarm required 5. Change of Occupancy Requirements (IEBC Chapter 10) a. Sprinkler required G. PLUMBING FIXTURE REQUIREMENTS (Chapter 29) Lower Level 1. Occupant Load 75 occupants (including exterior Terrace) 48 each gender 2. Men’s Restroom a. Toilets 1 b. Urinals 0 c. Lavatories 1 3. Women’s Restroom a. Toilets 1 b. Lavatories 1 4. Other Fixtures a. Drinking Fountains Water served to customers b. Service Sinks 1 5. Gender-separated facilitates Required (Local amended exception exceeded) 6. Unisex Restroom for Accessibility Not Required H. ESTES VALLEY DEVELOPMENT CODE 1. Zoning District CD - Commercial Downtown 2. Lot Area Approx 4,257sf = 0.098 Acres 3. Allowable Uses Tap Room and Residential Allowed 4. Setbacks Existing construction - no changes 5. Maximum Building Height 30'-0" (standard) > existing 19'-8" J. ENERGY CONSERVATION 1. No changes to existing building envelope 2. New mechanical equipment 3. New interior lighting 4. New exterior lighting K. STRUCTURAL DESIGN CRITERIA 1. Risk Category II Project Narrative Remodel of an existing 100 year old building to become a beer tasting room on the lower level while maintaining residential use on the upper level. The building becomes classified as a Group R2 Live/Work Unit. The residents will be Owners or Employees of the tasting room business. This classification negates most usual protections of the IEBC (Existing Building Code) which usually curtails IBC requirements in existing buildings. For a Live/Work unit, the IEBC classification for the project is BOTH "Alteration–Level 2", a the more restrictive "Change of Occupancy" classification. The project requires the addition of a NFPA 13R fire sprinkler system. There are no requirements for new fire-rated construction. The project requires two restrooms, both of which are to be considered unisex (both gender) access. One restroom is built in place of an existing restroom. The other is new and constructed to be fully wheelchair accessible. Beyond code requirements, the project involves the addition of a walk-in cooler, through-wall beer taps, new plumbing fixtures, new cabinetry, some changes to doors and windows, and new mechanical systems. Work on the upper level is limited. New water service (including a fire line) is to be brought into the building near the southeast corner. Existing sewer service is to be modified within the building. No additional restroom fixtures are added (although rearranged). A new 2-compartment sink, janitor sink, and some floor sinks are added in relation to the tap room use. Water heaters and furnaces are replaced on both levels of the building. New gas service enters near the SW corner of the building, replacing the current propane system which is to be removed. The electrical service to the east face of the building is being replaced/upgraded with new. The lower level tap room use is designated Suite A. The upper level residential use is designated Suite C for historic consistency. 1 1 1 5'-0" 5' - 0 " 4' - 1 0 " 5' - 0 " 4'-0" 3' - 0 " 4'-0" Clearance for toilet 60" x 60" Clearance for lavatory 36"W x 48"D Door Pull-Side Clearance Latch Approach 60"L x 48"W (door does not have a closer) Door Push-Side Clearance Hinge Approach 58"L x 42"W (door does not have a closer) Turning Circle 60" diameter 2' - 0 " 1' - 1 0 " 2' - 6 " 4'-0"4'-0" 2' - 6 " 5'-0"3'-0" 4' - 0 " 5' - 0 " 4'-6" 1'-6" Door Push-Side Clearance Front Approach 36"W x 48"D Door Pull-Side Clearance Front Approach 60"W x 60"D Turning Circle 60" diameter Customer side knee and toe space at accessible counter 30"W x 48"D 3'-8"44" between wall and accessible counter 3'-0" 3' - 0 " 36" accessible route Turning Circles 60" diameter Staff side knee and toe space at accessible counter 30"W x 48"D 5'-0 " 3'-6" 3'- 0 " 36" accessible route Accessible Route Scale: 1/4" = 1'-0"north 0 1 2 4 6 8 5 ' - 0 " Egress Path & Distance Scale: 1/8" = 1'-0"north 0 2 4 8 12 16 Upper Level Lower Level Upper Level longest egress path = 60'-0" Lower Level longest egress path = 45'-0" Existing egress windows Alternate egress path Alternate egress path Alternate egress path - not HC accessible 1 1 March 23, 2023 3/23/23 Sheet NumberA2 Joseph E Calvin Date Sheet Title Permit Information March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Lower Level Demolition 3D View Not to Scale n o r t h Lower Level Demoltiion Plan Scale: 1/4" = 1'-0"north 0 1 2 4 6 8 1'-0" 1' - 0 " 2' - 5 ½" 2' - 1 " 1' - 6 " 1'-0"7'-7"8'-0"4'-2½" 3' - 1 0 " 3' - 6 " 1'-0"1'-0" 2'-6" 7' - 6 " 1' - 0 " 9'-0" 8' - 8 " 3' - 1 0 ¼" 11'-6" 1' - 0 " 1'-0" Saw cut trenches in existing concrete slab for new waste & vent plumbing - re: Plumbing Southern extent of cutting can be omitted if existing lines can be reused Saw cut trenches in existing concrete slab for new waste & vent plumbing - re: Plumbing - Southern extent of cutting can be omitted if existing lines can be reused Recommend saw cutting existing slab to prevent further cracking Recommend saw cutting existing slab to prevent further cracking Temporarily remove this toilet, but maintain waste plumbing location Remove existing plumbing fixtures Remove existing plumbing fixtures Remove these windows - prepare openings for new windows Remove existing furnace Remove existing walls Remove existing side-lite windows Remove existing door Remove existing door Remove existing door Remove existing walls Maintain walls adjacent to stairway Remove existing water meter Remove existing electrical panelL Remove existing low stone wall Remove existing posts - provide temporary support Remove existing stairway and posts Coordinate saw cutting of slab with in this area with existing water and sewer entries Maintain existing floor slab except where shown otherwise 1'-10"1'-0" 1' - 0 " Remove existing propane tank and line to building Create opening in framed wall to expose existing brick masonry aesthetically Remove existing stone steps and complete face of stone wall - backfill with additional soil 3/23/23 Sheet NumberA3 Joseph E Calvin Date Sheet Title Lower Level Demoltiion Plan March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Upper Level Demolition 3D View Not to Scale n o r t h Upper Level Demoliton Plan Scale: 1/4" = 1'-0"north 0 1 2 4 6 8 Sun Room Living Dining Bathroom 52 sf Bedroom Bedroom Entry/ Stair Kitchen Hall Remove existing furnace prepare for replacement Remove toile and lavatory (which are crowded too close) prepare for relocation Remove existing water heater, cabinet & associated utilities Create opening for relocated door - install additional framing and blocking as appropriate Remove existing door and retain for reinstallation Relocate stove - see Sheet A5 Remove existing shelf & rod May be salvaged for reinstallation See Sheet A5 Create shaft openings in floor for new flues, vents, etc. Coordinate with MC & PC Remove existing shelving Create opening through structure for new floor drain Remove existing window and prepare opening for new replacement Remove existing electrical equipment and prepare for replacement - re: Electrical Provide temporary support for hip roof above, then completely remove south wall of sunroom Remove all sunroom windows prepare east and west openings for replacement windows Provide temporary support for hip roof above, then completely remove south wall of sunroom Remove all sunroom windows prepare east and west openings for replacement windows 1 March 23, 2023 3/23/23 Sheet NumberA4 Joseph E Calvin Date Sheet Title Upper Level Demoliton Plan March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Lower Level New Constuction 3D View Not to Scale n o r t h Lower Level New Construction Plan Scale: 1/4" = 1'-0"north 0 1 2 4 6 8 6'-5"3½"5'-4½"±8'-5" cooler outside 7' - 8 " 3½" 6' - 2 " ± 3½" 5'-6" 3½" 3'-8" 12 ' - 1 1 " 12 ' - 9 " b e n c h - V I F 3' - 8 " ± 3½" 7' - 8 " c o o l e r o u s i d e 3½" 3'-0" 6'-8" 1' - 3 " 3' - 8 ½"± Accessible Restroom 51 sf Unisex Restroom 33 sf FE G H 1 2 4 5 Mechanical Walk-In Cooler Bar Seating J1 J24'-11" 4'-0"11" 4' - 0 ½" 3 3'-5" 2' - 1 ¾" (8) through- wall beer taps 2' - 6 " 3½" 3' - 1 1 " 3½" 4' - 1 0 " 7'-2"11 ½" 11 ½" 2' - 0 " 4' - 1 1 ½" 1'-10" verify with equip 5½" 5½" 5½" Glass washer drain location - verify Floor sink Janitorial mop basin Floor sink Brass footrest Bar top height 3'-6" Accessible bar top height 2'-10"Patch concrete floor slab where new waste line plumbing is installed 2x6 framing at 12"oc - See plan below for height 2x6 framing at 12"oc - See plan below for height 3'-9"1'-11" Bar Wall Dimensions Scale: 1/4" = 1'-0" 0 1 2 4 6 8 1' - 8 " 4' - 5 " ( 4 ' - 6 " t o p ) 1' - 8 " 8' - 1 " 2-compartment sink legs Advance Tabco 2-comp Sink FE-2-1812-18R Janitor mop basin below Bar top height 3'-6" verify with sink below Fire sprinkler Riser within framed enclosure Floor Sink below - re: Plumbing FDFDFD FD Floor sinks re: Plumb Closet New gas furnace - extend ducts through Closet near ceiling - extend flue and air intake though crawlspace to existing shaft Crawlspace Restroom Accessories Surface Mounted Paper Towel Dispenser dispensing height at 48" aff max Sink Mirror — bottom of reflective surface at 40” aff max Protective Drain Pipe Padding Wall Mounted Soap Dispenser dispensing height at 48" aff max 36” Horizontal Grab Bar centered at 35” aff 42” Horizontal Grab Bar centered at 35” aff 18” Vertical Grab Bar at 40” aff Surface Mounted Large Roll Toilet Paper Dispenser Sanitary Napkin Disposal - Both Restrooms Coat Hook / Door Bumper at 42” aff 24"W x 30"T Bobrick B-5050 1 2 3 4 5 6 7 8 9 10 Bobrick B-4262 Bobrick B-5806-36 Bobrick B-5806-42 Bobrick B-5806-18 Bobrick B-2892 Bobrick B-270 Bobrick B-212 Baby Changing Station – 42¼" aff to top bolts11 Koala/Bobrick KB-200 1 2 3 4 5 6 7 8 10 11 3 1 9 New upholstered bench seating Upper stone steps re: Sheet A6 Provide cover for crawlspace access panel Provide Crawlspace access panel low through cooler panel wall - Cover to match insulation See 3D view for Crawlspace Access Panel abpve 1' - 6 " 1' - 8 " Accessible Restroom Elevations1Scale: 1/4" = 1'-0" 0 1 2 4 6 8 Knee & toe clearances per ICC A117.1 Sect 306 9" 1' - 6 " 6" ± 8" 4' - 0 " m a x to p o f o p e r a b l e p a r t s Door stop Mechanical chase/soffit Light -re: elec 3'-0"6" 2'-0"1'-0"1'-0"3'-6" 3'-4" 1' - 1 1 " 2' - 1 1 " 2' - 3 " 2' - 6 " 2'-0" min 4' - 0 " 3' - 4 " New water heater - re: Plumbing Below ducts - requires 72" aff Crawlspace Access Panel Wall mounted light fixture - re: Elec All restroom walls tile full height Floor tile - typ at restrooms Sprinkler & domestic pipe risers Deck Posts - re: Structural & Sheet A12 1 A6 Trench with Steel Plate for Water Line or alternately PVC sweep - re: Plumbing 8'-2¾" 6¾"3'-0"6"3'-8"6" 4'-11½" 2"1'-0" 4½" 3'-2"3" Construct new exterior walls offset flush exterior within existing openings 8'-9" 2'-0" 3'-11"1'-8"5'-5"1'-8"4'-10½" 2'-0" 1 A10 1 A10 2 A10 2 A10 Knox Box 3200 - verify model and location with Fire Department Type ABC 10-lb fire extinguisher on wall bracket Verify min 4'-0" clr 1 1 March 23, 2023 3½" 3/23/23 Sheet NumberA5 Joseph E Calvin Date Sheet Title Lower Level New Construction Plan March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Upper Level New Construction 3D View Not to Scale n o r t h Upper Level New Construction Plan Scale: 1/4" = 1'-0"north 0 1 2 4 6 8 Sun Room Living Dining Bathroom 52 sf Bedroom Bedroom Entry/ Stair KitchenHall New sprinkler riser A B C1 C2 C3 C4 D K 1 A12 2 A12 Natural stone steps Uniform thickness - max 7" Approx 15" tread length Set into grade Steel pipe railings similar to min 3'-0" between railings Lower Stair Railing - see detail 3/A12 similar - Consult with Architect on final design 8 T @ 1 1 " = 7 ' - 4 " 9 R @ 6 13 /16 " = 6 ' - 1 ¼" up New plumbing fixtures and vanity cabinetry New gas furnaceReinstall existing door New infill wall construction patch plaster finishes New 15" drawer base with countertop with (2) backsplashes and upper cabinets Relocate electric stove as shown New (4) 2x6 stud packs New sign below - see Sheet A8 New floor drain - extend from exist nearby drain line New tankless water heater re: Plumbing - extend flue and air-intake through wall & caulk New or reinstall shelf & rod New wall construction New flues and vents Coordinate with MC & PC Expanded mechanical chase 3'-11" 2'-6" clr 2'- 1 0 " 2'- 0 "Support spanning countertop with 1¾"x 11⅞" LVL centered below Open knee space to allow for forward wheelchair approach from either side Accessible Countertop1Scale: 1/16" = 1'-0"nor t h 1 A10 1 A10 2 A10 2 A10 Type ABC 10-lb fire extinguisher on wall bracket Regrade if and as needed east of the stairway to ensure that grade is not lower than step noses by 30" within 36" horizontally 1 1 March 23, 20231March 23, 2023 Completely rebuild south wall of sunroom - re: 4/S2 4 S2 1 3/23/23 Sheet NumberA6 Joseph E Calvin Date Sheet Title Upper Level New Construction Plan March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Roof 3D View Not to Scale n o r t h Roof Plan Scale: 1/4" = 1'-0"north 0 1 2 4 6 8 Remove and replace existing shingle roofing at existing hip roof - install over new Grace Ice & Water Shield New prefinished metal gutters and downspouts GC to examine and repair parapet cap flashing and brick work - typ 3/23/23 Sheet NumberA7 Joseph E Calvin Date Sheet Title Roof Plan March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 South Elevation Scale: 1/4" = 1'-0" 0 1 2 4 6 8 West Elevation Scale: 1/4" = 1'-0" 0 1 2 4 6 8 A B C1 C2 C3 C4 E F G H 1 A12 Existing utility pole LExisting fire hydrant Existing Stone WallWhere existing steps are removed, infill new stone to match existing Lower stair railing - see detail 3/A12 1 S2 1' - 2 " 10 " 12'-0" 8'-0" Tenant sign fabricated from steel beams and back-face illuminated - approx dimensions shown Replace select windows New infill wall framing New prefinished metal gutters and downspouts Remove and replace existing shingle roofing at existing hip roof - install over new Grace Ice & Water Shield GC to examine and repair parapet cap flashing and brick work - typ GC to examine and repair parapet cap flashing and brick work - typ No other work west elevation Approx outline of neighboring building New gas meter New log column - re: detail 1/S2 Tenant sign - see South Elevaion Replace select windows Remove and replace existing shingle roofing at existing hip roof - install over new Grace Ice & Water Shield New prefinished metal gutters and downspouts 10" tall address numerals - contrasting color 10" suite letter - contrasting color Knox Box 3200 - verify model and location with Fire Department 10" suite letter - contrasting color 1 March 23, 2023 Completely rebuild south wall of Sunroom per 4/S2 1 3/23/23 Sheet NumberA8 Joseph E Calvin Date Sheet Title Exterior Elevations March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 North Elevation Scale: 1/4" = 1'-0" 0 1 2 4 6 8 East Elevation Scale: 1/4" = 1'-0" 0 1 2 4 6 8 D J1 J2 K 2 A12 Sht E1 New electric service Steel pipe railings similar to min 3'-0" between railings Lower Stair Railing - see detail 3/A12 similar - Consult with Architect on final design Natural stone steps Uniform thickness - max 7" Approx 15" tread length Set into grade Replace select windows New deck construction No work - north elevation Remove and replace existing shingle roofing at existing hip roof - install over new Grace Ice & Water Shield New prefinished metal gutters and downspouts Reinstall existing historic sign New light in soffit - re: Elec 3/23/23 Sheet NumberA9 Joseph E Calvin Date Sheet Title Exterior Elevations March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 2 1 Long Section Scale: 1/4" = 1'-0" 0 1 2 4 6 8 Cross Section Scale: 1/4" = 1'-0" 0 1 2 4 6 8 9"6"5" 3' - 6 " 1 A6 1 S2 Living Dining BedroomLivingHall 2 A10 2 A10 MechClosetBarSeating Sun Room Crawl Space 1 A10 1 A10 Sign - re: Sheet A8 BarSeating Refer tp Sheet S1 for sistering of joists ⅝" gypsum board on bottom of joists - metal ceiling panels by Tenant ⅝" gypsum board on bottom of joists - metal ceiling panels by Tenant Steel Beam - re Sheet S1 Duct work 1' - 0 " 2'-0" Mechanical Chase Drywall Soffit Upholstered bench Expose existing brick Expose existing brick 1 A12 2 A12 Restroom sign See detail 3/A11 1 March 23, 2023 Completely rebuild south wall of sunroom 4 S2 1 3/23/23 Sheet NumberA10 Joseph E Calvin Date Sheet Title Building Sections March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 1'-3"1'-6" 3' - 4 " 3' - 6 " 4'-9"6"4'-9"6"4'-9"6"4'-9" 3' - 0 " 3' - 6 " 1'-6" 3' - 6 " 3' - 0 " 3' - 0 " 3' - 2 " 4'-0" 2' - 8 " 3' - 9 " ± 2' - 6 " 4' - 5 3 / 4 " 2' - 6 " 4' - 5 3 / 4 " 6' - 0 " 3'-2"4½"1'-0" 6' - 0 " 6' - 9 " Exterior Window and Door Elevations Scale: 1/4" = 1'-0" 0 1 2 4 6 8 A B C1 C2 C3 C4 D E F G H J1 J2 K Fixed Direct Set Aluminum Clad Wood Double Pane Low-E Glass U-value: 0.26 Qty: 1 each Slider or Pair Casements Aluminum Clad Wood Double Pane Low-E Glass U-value: 0.26 - Qty: 1 New Dutch Door seen from exterior push side Aluminum Clad Wood Double Pane Low-E Glass U-value: 0.33 Entrance Set, Hinges,Weather Strip Threshold & Sweep - Qty: 1 T T T T T T Fixed Direct Set - Aluminum Clad Wood Double Pane Low-E Glass U-value: 0.26 - Qty: 3 Fixed Direct Set Aluminum Clad Wood Double Pane Low-E Glass Tempered Glass U-value: 0.26 Qty: 1 each New Direct Set Window Double Pane Low-E Glass U-value: 0.26 Safety Glass Exist Direct Set Window verified Safety Glass New Half-Lite Door as seen from exterior Insulated Hollow Metal Insulated Glass, Entrance Set Weather seal, Closer with hold open function, Weather Strip, ADA compliant Threshold Fixed Direct Set Aluminum Clad Wood Double Pane Low-E Glass U-value: 0.26 Qty: 1 Verify existing RO size Fixed Direct Set Aluminum Clad Wood Double Pane Low-E Glass U-value: 0.26 Qty: 1 Verify existing RO size Lower level finish floor elevation Upper level finish floor elevation General Notes 1. Field verify all rough openings and finish wall thickness prior to ordering or fabrication of materials. 2. Door and window details indicate typical situations. Consult Architect regarding special conditions if encountered. Windows are illustrated from the exterior. Swing doors are illustrated from the pull-side unless noted otherwise. 3. Contractor to run a continuous bead of sealant around all doors, windows, and other openings or joints. Leave adjacent surfaces clean. Provide backer rod where necessary. 4. Provide hardware finish samples for Owner's selection prior to ordering. 5. Provide wall stops or overhead stops at all interior swinging doors. 6. Provide 2x8 blocking in framed walls for door stops, cabinetry, shelving, kitchen and toilet accessories, etc. 7. Panes of glass marked "T" on Elevations are to be tempered (safety glass). Door and window supplier shall be responsible for bidding and supplying tempered unit as required by code, including but not limited to those shown. 8. Supplier shall be responsible for verification of all window quantities, window sizes, and rough opening sizes as related to matching door & window rough openings so that trim aligns. 9. Glass in all exterior windows shall be Pella Duel-Pane High-Altitude (air-filled) Advanced Low-E with U-values of max U0.33 for 3mm glass and U0.32 for 2.5 mm glass. Interior Door Elevations Scale: 1/4" = 1'-0" 0 1 2 4 6 8 1 Unisex Restroom as seen from push side Wood Solid Core Door Privacy Set, Pull-Side Closer, Hinges, Wall Stop Qty: 1 2 Accessible Restroom as seen from push side Wood Solid Core Door Privacy Set, Pull-Side Closer, Hinges, Wall Stop Qty: 1 3 Mechanical as seen from pull side Wood Solid Core Door Passage Set Hinges, Overhead Stop Qty: 1 4 Closet as seen from pull side Wood Solid Core Door Privacy Set Hinges, Wall Stop Qty: 1 5 Walk-In Cooler Door by Cooler Panel Supplier Interior-side push latch release Pedestal type tall heavy duty floor stop Qty: 1 3'-0" 7' - 0 " 2'-0"1'-6" 3'-6" 6' - 8 " 3'-0" 6' - 8 " 3'-0" 6' - 8 " 2'-8" 6' - 8 " 6' - 9 " 3'-0"6"3'-8" 3'-6"3'-6" Restroom Signs1Scale: 3" = 1'-0" 0 1”3”2”3”4”5”6”7”8” 5' - 0 " a f f 1' - 0 " ϕ ¼" thick plastic sign Raised equilateral triangle Raised plastic figures International Symbol of Accessibility at north restroom only - omit this figure at south restroom Grade 2 Braille Normally, restroom signs are to be installed adjacent to the latch side of restroom doors. However, due to the small existing conditions of this building, install the signs centered on the door face. T 1 1 1 March 23, 2023 3/23/23 Sheet NumberA11 Joseph E Calvin Date Sheet Title Openings and Details March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Stair Elevation2Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0" Stair Section1Scale: 3/4" = 1'-0" 0 6”1’-0”2’-0”1’-6”2’-6” 11" 613 /16 " 3' - 0 " (8) treads at 11" = 7'-4" ( 9 ) r i s e r s a t 6 13 /16 " = 5 ' - 1 ¼" f i e l d v e r i f y Stair Railings3Not to Scale Upper Stairway West Railing 1½" steel pipe - radius all transitions and fully weld - cap pipe ends for full closure - grind all joints - prime and epoxy paint Upper Stairway Wast Railing 1½" steel pipe - radius all transitions and fully weld - cap pipe ends for full closure - grind all joints - prime and epoxy paint Extend lower end 12" radius back 180° and return back 9" Bracket to post Bracket to post Extend upper end 12" and radius back toward guard 90° Radius 90° around corner and extend 12" - radius back to wall another 90° Post down to upper deck level See section 1/A12 Post down to stringer See section 1/A12 Extend lower end 12" north, radius down 12" and back to post Lower Stair Railings Qty: 2 1½" steel pipe - radius all transitions and fully weld - grind all joints - prime and epoxy paint Extend lower ends 6" embedment into concrete 2x6 treated cap or synthetic 2x4 sub railing Steel cable railing system 3½" oc - or alternately decorative metal railing by Owner which prevents passage of 4" sphere Steel cable railing system 3½" oc - or alternately decorative metal railing by Owner which prevents passage of 4" sphere 3' - 7 ½" ( 3 ' - 6 " m i n ) 3' - 7 ¾" ( 3 ' - 6 " m i n ) (2) ½" x 9" lag bolts throught post into end of stringer 1'-0" Steel pipe railing extension - see 3/A12 Simpson StrongTie ABU66Z post bases - typical all three posts this detail 4x12 DF beam and stringer supported off posts with Simpson StrongTie CJT5Z concealed hangers - typ 6x6 DF Posts 11 ' - 2 " p o s t - v e r i f y 9' - 9 " p o s t - v e r i f y 4' - 2 ¼" p o s t - v e r i f y 4x12 DF beam and stringer supported off posts and ledger with Simpson StrongTie CJT5Z concealed hangers - typ 2x12 DF decking to match treads 2"x5"x¼" stl plate with (2) 1/2"x3" lags 2"x7"x¼" stl plate with (2) 1/2"x3" lags Bottom of wall-mounted stringer to clear grade (4) ¾"ϕ x 9" threaded rods inserted into Hilti HIT-SC 26x200 epoxy screen tube sleeves following mfgr's installation instructions and timing - fasten stringer with nuts and washers 4x12 x 38"long DF stair treads 35/16 " c l e a r 2"x2"x¼" x 9" long steel angles at both ends of each tread - fasten to stringer and tread with (4) ½" x 3" lag bolts Lower stair railings See detail 3/A12 Line of existing grade 5'-8"7'-4" Align deck ½" below upper `level finish floor elevation 1½" steel pipe railing - radius all transitions and fully weld - cap pipe ends for full closure - grind all joints - prime and epoxy paint - Refer to detail 3/A12 for additional requirements 2x6 treated cap or synthetic 2x4 sub railing Steel cable railing system 3½" oc - or alternately decorative metal railing by Owner which prevents passage of 4" sphere Line of grade 10"ϕ x 48" sonotube conc pier with (3) #4 vert & (3) #3 ties - typ - chamfer top edge 3/4" Stair tread lights re: Electrical 3' - 1 1 " ± ( 2 ' - 6 " m i n b e l o w g r a d e - t y p ) 1 1 March 23, 2023 3/23/23 Sheet NumberA12 Joseph E Calvin Date Sheet Title Stair Section March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 Foundation Plan Scale: 1/4" = 1'-0"north 0 1 2 4 6 8First Floor Framing Plan Scale: 1/4" = 1'-0"north 0 1 2 4 6 8 Nailing Schedule Joint Description Number of Common Nails Number of Box Nails Nail Spacing WALL FRAMING Top Plate to Top Plate (Face-Nailed)(2) 16d (2) 16d per foot Top Plates at Intersection (Face-Nailed)(4) 16d (5) 16d joints-each side Stud to Stud (Face-Nailed)(2) 16d (2) 16d 24" oc Header to Header (Face-Nailed 16d 16d 16" oc along edges Top or Bottom Plate to Stud (End-Nailed)(3) 16d (3) 40d per stud Bottom Plate to Floor Joist, Bandjoist, Endjoist or Blocking (Face-Nailed)(2) 16d (2) 16d per foot FLOOR FRAMING Joists to Sill, Top Plate or Girder (Toe-Nailed)(4) 8d (4) 10d per joist Bridging to Joist (Toe-Nailed)(2) 8d (2) 10d each end Blocking to Joist (Toe-Nailed)(2) 8d (2) 10d each end Blocking to Sill or Top Plate (Toe-Nailed)(3) 16d (4) 16d each block Ledger Strip to Beam (Face-Nailed)(3) 16d (4) 16d each joist Joist on Ledger to Beam (Toe-Nailed)(3) 8d (3) 10d per joist Band Joist to Joist (End-Nailed)(3) 16d (4) 16d per joist Band Joist to Sill or Top Plate (Toe-Nailed)(2) 16d (3) 16d per foot Framing Notes STRUCTURAL WOOD FRAMING: a.Except where noted otherwise, all 2" lumber shall be Douglas Fir-Larch S4S #2 or better, and all solid timber beams and posts shall be Douglas Fir-Larch #1. Any proposed reclaimed lumber certified or graded by qualified professional to have equal or better properties than Douglas Fir Larch #1. b. 2x6 studs shall be Douglas Fir-Larch #2 or better. 2x4 studs shall be Stud grade or better Douglas Fir-Larch or Hem-Fir unless noted otherwise on the Drawings. c. Top and bottom plates shall be Douglas Fir-Larch #2 and better. d. Provide solid blocking at supports for wood joists. Within floor joist spaces beneath solid or built-up columns noted on Plans, blocking of area equivalent to column above shall be provided for proper load transfer. e. Provide solid blocking between joists above wall framing below and below wall framing above. f. Except as noted otherwise, minimum nailing shall be provided per the Nailing Schedule this sheet. g. 2x6 studs shall be nailed to top plate with (2) 16d end nails and to sill plate with (3) 8d toenails or (2) 16d end nails. h. Unless otherwise noted, steel connectors such as those manufactured by the Simpson Company shall be used to join rafters, trusses, joists, or beams to other members at flush-framed conditions. Connector conditions not otherwise noted shall utilize hangers of a size specifically designed for the member supported, as shown in Manufacturer's published tables. j.All wood framing members in contact with concrete or CMU shall be either redwood or pressure treated. k. All architecturally exposed beams to be weather-resistant with stained finish. Exterior Walls: a. All exterior walls are 2x6 studs at 16" oc unless noted or dimensioned otherwise. Exterior bearing wall heights above 10'-0" are to be constructed of 2x6 Hem Fir #2 Studs at 16" oc. b. Provide (2) 2x10 header with (1) trimmer and (2) king studs at all new door & window openings unless otherwise noted. c. At beam bearing locations in stud walls, provide multiple-stud posts equal to width of bearing member unless noted otherwise. Interior Walls: a. Interior walls shall be 2x4 studs full height at 16" oc unless noted or dimensioned otherwise. b. Provide (2) 2x4 header with (1) 2x4 trimmer and (2) 2x4 king studs at each side of door & window openings typical unless noted otherwise on Plan. FOUNDATION DESIGN: Design of individual and continuous footings is based on a maximum allowable bearing pressure of 2500 lbs per square foot (dead load plus full live load) placed on the undisturbed natural soils, compacted structural fill or native stone, below frost depth. CAST-IN-PLACE CONCRETE: a. All concrete design is based on the "Building Code Requirements for Reinforced Concrete" (ACI 318). b. All structural concrete shall have minimum 28-day compressive strengths as follows: Footings 3000 psi; slabs on grade 3500 psi. c. Concrete shall be proportioned utilizing Type 1/11 cement. Concrete susceptible to freezing shall be formulated for maximum frost resistance in accordance with "ACI Manual of Concrete Practice". d.Cold weather and/or hot weather concreting procedures shall be provided, if conditions warrant, as recommended in the "ACI Manual of Concrete Practice". e.All anchor bolts shall be located at a minimum of 5 bolt diameters from concrete edge. Concrete footing and foundation shall have min frost protection of 30" to grade. Exterior deck piers shall be poured to elevations as shown on plans. f. Contractor verify top of footing and top of concrete elevations with existing and proposed grade. g. Saw-cut slab control joints shall be min 1" deep & min 12'-0" oc or less as may be shown on Plans. h. Place new slabs over 10-mil poly vapor barrier over 4" free-draining gravel over existing compacted soil. Refer to Sections for below-slab insulation. REINFORCING STEEL: a. All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the "ACI Manual of Concrete Practice". b. Reinforcing bars shall conform to ASTM Specification A615 and shall be Grade 60, except ties, field bent bars where permitted by Note on Plan, or bars to be welded which shall be Grade 40. c. At splices, lap bars 36 diameters. At corners, make horizontal bars continuous or provide corner bars. Around openings in walls and slabs, provide (2) #5's extending 2'-0" beyond edge of opening. d. Except as noted on the Drawings, minimum concrete protection for reinforcement shall be in accordance with ACI 318. e. Welded wire fabric shall conform to ASTM Specification A-185. ANCHOR BOLTS: Shall conform to ASTM F1554 Grade 36 with a min ½" diameter by 12" length. Anchor bolts shall be placed within 12" from building corners, concrete cold joints, and sill plates and shall be spaced at a maximum of 48" oc. Additional anchor bolt details shall be in accordance with the Drawing. Sill plates shall be held down at all anchor bolts with 3" x 3" x 3/16" plate washers. Foundation Notes W1 0 x 2 6 S t e e l B e a m D r o p p e d ` 2x6 top plate (4) 2x4 stud pack in wall below 19 ' - 6 " 8' - 6 " 11'-0"12'-3" Se e " F i e l d E n g i n e e r i n g N o t e " f o r a d d i t i o n a l r e q u i r e m e n t s Sis t e r n e w 2 x 8 t o e x i s t i n g 2 x 8 f l o o r j o i s t s FIELD ENGINEERING NOTE 1 - Engineer and CG to verify in the field which floor joists are structurally compromised and need repair 2 - Compromised joists can be sistered with (2)2x8 or (1)1¾"x 7¼" LVLs 3 - Non-compromised joists can be sistered with (1)2x8 for a final member of (2) 2x8 as illustrated Se e " F i e l d E n g i n e e r i n g N o t e " f o r a d d i t i o n a l r e q u i r e m e n t s Sis t e r n e w 2 x 8 t o e x i s t i n g 2 x 8 f l o o r j o i s t s Ne w B e a m (3 ) 1 ¾"x 7 ¼" L V L f l u s h Ex i s t i n g B e a m Ve r i f y m i n ( 2 ) 2 x 8 Ex i s t i n g B e a m Ve r i f y m i n ( 2 ) 2 x 8 New Beam (3)1¾"x7½" LVL Beam flush 8"ϕ log post down to top of stone - typ of 3 8"ϕ log post down to top of stone - typ of 3 to e x i s t j o i s t s Sis t e r n e w 2 x 8 to e x i s t j o i s t s Sis t e r n e w 2 x 8 12" ϕ concrete pier with 24" ϕ "Bigfoot" footing form min 30" deep below finish grade Reinforce with (3)#4 vert and (3) #3 ties Note: Existing rafters at Sunroom roof above run north-south 10'-8"10'-8" New 2x4 at 12"oc bearing wall below north end of steel beam (4) 2x4 stud pack in wall below 5' - 8 " 1¾" 7' - 4 " 3'-7½" 10"ϕ x 48" sonotube conc pier with (3) #4 vert & (3) #3 ties - typ - chamfer top edge 3/4" TO Pier 3'-0" above lower level FF TO Pier 4" above lower level FF 12" ocPT 2x8 3x10 DF Beam New pad footing or thickened slab centered below stud pack 24" sq x 10" thick with (3) #4 ea way 4x4 x 3'-6" post with Simpson AC4 brackets both sides Simpson StrongTie CJT5Z concealed beam hanger 6x6 post - 11'-2" tall with (2) Simpson StrongTie CJT5Z hanger 6x6 post 9'-9" tall 3x 1 0 D F B e a m 3x10 DF Beam Simpson StrongTie LU28 joist hangers - typ (3) Simpson StrongTie CJT5Z concealed beam hanger Drop north beam 2" below upper level finish floor - other beams ½" below finish floor 3x 1 0 D F S t r i n g e r 3x 1 0 D F S t r i n g e r Simpson StrongTie CJT5Z concealed beam hanger 6x6 post - all (3) deck posts to be mounted to concrete with Simpson StrongTie ABU66Z bases 4x12 DF stair treads supported on steel angles - see Section 1/A12 (4) ¾"ϕ x 9" threaded rods inserted into Hilti HIT-SC 26x200 epoxy screen tube sleeves following mfgr's installation instructions and timing 5' - 8 " 10"ϕ x 48" sonotube conc pier with (3) #4 vert & (3) #3 ties - typ - chamfer top edge 3/4" TO Pier 1'-9" above lower level FF 1 March 23, 2023 Existing beam pocket in solid concrete wall Existing beam pockets in solid concrete wall 1 1 1 Simpson HU68 hanger 1 8”x16” continuous footing w/ (2)#4 longitudinal 1 1 Lace arrangement of beams at corner - fasten each lap with (2) min 4" screws from 2 sides 1 Sheet NumberA13 Joseph E Calvin Date Sheet Title Foundation and Framing Plan March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 of 2 S1 David Bangs, PE 12" ϕ concrete pier with 24" ϕ "Bigfoot" footing form (3) #4 vert bars - 32" tall (3) #3 ties 2'-0" 2' - 6 " 1'-0" Non-shrink epoxy-based structural grout Steel kerf plate - see detail 2/S2 8" diameter log post Kerf cut Extent of Kerf cuts Steel kerf and bearing plate assembly - see detail 3/S2 New of existing perimeter floor beam See Framing Plan Sheet S1 Concrete paving per Town's Cleave Street Project ½" expansion joint material - caulk Log Post Section1Scale: 3/4" = 1'-0" 0 6”1’-0”2’-0”1’-6”2’-6”Lower Steel Assembly2Scale: 3" = 1'-0" 0 1”3”2”3”4”5”6”7”8”Upper Steel Assembly3Scale: 3" = 1'-0" 0 1”3”2”3”4”5”6”7”8” (2) ¾" bolts 3"oc and 1½" from bottom edge of steel - with washers both ends - counter sink into post (2) ¾" bolts 3"oc and 1½" from north edge of steel - with washers both ends (2) ¾" bolts 3"oc and 1½" from top edge of steel - with washers both ends - counter sink into post ¼" steel plate ⅜" steel plate ¼" steel plate ¼" steel plate ¼" steel plate ¼" typ ¼"typ ⅜" steel plate ¾"x10"x4" ASTM F1554 Grade 36 anchor bolt - threaded with nut New Beam (3)1¾"x7½" LVL BeamReglet and flashing 12" log shaped around new beam and existing construction 6" 5" ¾" chamfer top edge of concrete pier 1 1 March 23, 2023 21'-9½" ± 4'-9" typ 3' - 3 ½" 7' - 6 " ± m a t c h e x i s t (2)1¾"x7¼" LVL header full width cont 6" Double 2x4 top plate (4)2x4 jack stud pack - typ 2x4 at 16"ocL cripple framing J Verify sign lighting junction box with Tenant's sign fabricator (2) Simpson CS14 x 28" strap ties - fold across bottom of new triple LVL floor beam(2) Simpson CS14 x 28" strap ties - fold across bottom of new triple LVL floor beam (2)2x4 jack studs (2) full-height 2x4 king suds Fasten solidly to existing perpendicular framing Simpson CS14 x 54" strap tie extend up and over top of wall and down interior face by 24" Simpson CS14 x 54" strap tie extend up and over top of wall and down interior face by 24" Verify RO window size with mfgr Place (in 2 applications) full-depth spray-applied close-cell polyurethane insulation win all stud spaces & cavities New Sunroom South Wall Framing & Insulation4Scale: 1/2" = 1'-0" 0 6"1'-0"2'-0"3'-0"4'-0" 1 Sheet NumberA14 Joseph E Calvin Date Sheet Title Structural Details March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 of 2 S2 David Bangs, PE 3/13/23 Sheet NumberP0 Joseph E Calvin Date Sheet Title Plumbing Specification March 3, 2023 of 4 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 ©2023 Interstice Architectural Studio, LLC 3/13/23 Sheet NumberP1 Joseph E Calvin Date Sheet Title Plumbing Schedule & Notes March 3, 2023 of 4 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 ©2023 Interstice Architectural Studio, LLC ALTERNATE WATER PIPE CHASE 5 P-2 MIN 3" Φ PVC CHASE CONCRETE SLAB WALL CONSTRUCTION RADIUSED SWEEPS, NOT TIGHT ELBOWS PEX PIPING TO GLASS WASHER NO SPLICES WITHIN CHASE PIPE TERMINATION OR GROUND SMOOTH EDGE 1 1 March 13, 2023 MIN R3 PIPE INSULATION 1 3/13/23 Sheet NumberP2 Joseph E Calvin Date Sheet Title Plumbing Diagrams March 3, 2023 of 4 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 ©2023 Interstice Architectural Studio, LLC SEE ALTERNATE WATER PIPE CASE DETAIL 5/P2 INSTALL MIN R3 PIPE INSULATION 1 3/13/23 Sheet NumberP3 Joseph E Calvin Date Sheet Title Plumbing Plans March 3, 2023 of 4 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 ©2023 Interstice Architectural Studio, LLC Electrical Service One-Line Diagram Not to Scale Lower level panel: Flush Mount, 120/240 volt, single phase, 3-wire, 200 amp, 20 spaces minimum, 22 KA rated. Circuit Breakers: 1-50 A. 2-pole (truck rec.), 1-30 A. 2-pole (AC condenser), 1-30 A. 2-pole (dishwasher), remainder are 1-P, 20 A. rated except provide 1p 15 amp breakers if existing circuits are used with 14ga. wiring. Upper level panel: Flush Mount, 120/240 volt, single phase, 3-wire, 125 amp, 16 spaces minimum, 22 KA rated. Circuit Breakers: 1-50 A. 2-pole (stove), 1-30 A. 2-pole (washer/dryer), 1-30 A. 2-pole (AC). 5-1 pole 15 A. for existing 14ga. circuits and the remainder 20A. 1-pole for any new wiring (adjust to 15 A. 1-pole if necessary). Panel Schedule 6' - 6 " New Lower Level Panel 1ϕ - 3 wire, 120/240V, 200 A. rated flush mounted 3" steel galv. conduit 2-500 MCM & 1-250 MCM alum =75°C rated insul See Notes SC - 15,605 Electrical Site Plan Scale: 1/8" = 1'-0"north 0 2 4 8 12 16 E E E Truck connect rec. 50 amp mount in pedestal at 4'-0" 3 - #6 below grade below new stair New electric service meter panel & building service panel disconnect switches (and possible temp. service overhead) 3" PVC Sched 40 Recommend 2-500 MCM AL phase legs 250 MCM neutral, 1ϕ - 3w 120/240V svc Approx location of future underground service pencell box General Notes 1. Carefully coordinate the electrical work with the General Contractor. 2 This project will have a Service Change sometime in the Summer of 2023 if the scheduled work by Estes Park Light and Power and the summer road work downtown is under construction per schedule. Light and Power is upgrading their electrical service work in the area of this building to an underground service. A Pencell box is tentatively indicated on the North side of the street and East of the building. This is where the new UG service to the building will be served. Until that work is in place, a temporary overhead service will be required (per the 1-line drwg.). This overhead service will be required to put the Building into service until the transition to the underground is in place. 3. Considering the above, if the site work East of the building is to be completed prior to the upgraded road work, the underground conduit should be installed. Coordinate this with the General Contractor. 4. As noted on the drawings, the new panel locations should be the existing locations with the old panels removed. This is likely the case in the upstairs, but there has been conversation regarding changing the location of the downstairs panel. Should this moving be required, then any existing circuits that are reused will have to be routed to the new locations and a pull/junction box installed to facilitate the splicing of the existing circuits and the routing to an alternate location. Again, coordination with the General Contractor is necessary if this is desired. 5. Again, per the above, any changes in interior panel location should be resolved before any routing from the new service metering and main entrance panel is initiated. 6. The Electrical Work per the 2020 NEC. 7. Conductors for the Service are based on 75 degree C. rated Aluminum wire type RHW, THW, THWN, THHW, etc. If copper wire is desired then the size can be modified that meets or exceeds the rating of the AL wire indicated. 8. Branch circuit wiring is Copper.Existing Building Cleave Street New Apt. Panel 1ϕ - 3 wire, 120/240V, 125 A. rated flush mounted 200 A. meter base 100 A. meter base 175A 100A #2 copper to ground (also bond to water service) Weatherhead Temporary overhead service 1ϕ - 3 wire To Bar/Restrm Panel Main Level 2-250 & 1-3/0 AL in 2" steel conduit General duty NEMA 3R 200A., 120/240V, 3W 2-blade & fused disconnect General duty NEMA 3R 100A., 120/240V, 3W 2-blade & fused disconnect 12"x30"x5" NEMA 3R gutter 24" bury min 2-500 MCM & 1-250 MCM neut AL in 3" sch. 40 PVC to J-box See Electrical Site Plan Finish grade Class R or J Fuses 2-1/0 & 1-#2 AL in 1½" steel conduit To Apt Panel 2nd Level Property lines Sheet NumberA15 Joseph E Calvin Date Sheet Title Electrical Site Plan & One-Line Diagram March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 of 2 E1 Walter E Steige, PE CO SD SD SD SD CO J J J GFI +30"GFI GFI GFI +38" GFI +30" GFI J J J WP +30" WP +30" J J J SD General Notes WP GFI 220v Electric Legend 1. Lighting locations shown take precedence over other ceiling-mounted items -- these plans shows locations. In the case of conflict, lighting locations take precedence. 2. All interior framed walls are to be constructed full-height to under side of roof or floor deck above unless indicated otherwise. 3. Note that lower level ceilings this project are slightly lower than 8'-0" aff. 4. Electrical contractor is to be responsible for working with the GC and Owner on the details of this plan on a "Design-Build" basis, including the following: a. Selection of fixtures, devices, and plates. b. Service including expanding/adding: transformers, meters, panels & sub- panels, circuits, disconnects & other switches, distribution & devices. c. Requirements to meet Local and State of Colorado Code regulations, including the 2020 National Electric Code. d. Power needed for mechanical equipment, appliances, and other equipment & systems. e. Locating thermostatic controls. 4. All smoke and CO detectors shall be wired directly to electrical panel and interconnected so that actuation of one device will activate all alarms. 5. All exterior lighting fixtures shall be shielded, downward directed, and compliant with dark sky regulations. Exterior lights illustrated this project or downward directed recessed soffit lights. 6. The Owner has expressed interest in a lighting control system. EC, please prepare a proposal for products, arrangement and scenes for the Owner to review and consider. Also review selection with the Electrical Engineer. 24" long LED light with shatter proof protective covering install on wall above door LED light panel - existing product by GC Recessed can light into ceiling - wall-wash lens directed as shown Wall-mounted bathroom light fixture near ceiling Ceiling mounted light fixture with protective cage - cold location Recessed or exterior grade light fixture Wet location recessed or under-deck-mounted can light Track Lighting Bathroom exhaust fan - coordinate power and location with MC Light Switch Multi-Way Switch Dimmer Switch (momentary digital compatible with Lighting Control System) Occupancy Sensor Standard Duplex Outlet - mounted at 18" aff unless noted otherwise Quad Outlet mounted at 18" aff unless noted otherwise Exterior/Waterproof Outlet with protective cover Ground Fault Circuit Interrupt protected Outlet - height as noted 220v Outlet Smoke Detector Carbon Monoxide Detector Junction Box - refer to plans for usage Data port - Ethernet RJ45 except where noted otherwise Thermostat Distribution Panel Electric Meter Utility Pole 3 3 3 OS OS OS US B - C + 3 8 " US B - A + 3 8 " GF I + 3 8 " CO SD J T T T D D GFI Lower Level Power Plan Scale: 1/8" = 1'-0"north 0 2 4 8 12 16 Upper Level Power Plan Scale: 1/8" = 1'-0"north 0 2 4 8 12 16 Lower Level Lighting Plan Scale: 1/8" = 1'-0"north 0 2 4 8 12 16 Upper Level Lighting Plan Scale: 1/8" = 1'-0"north 0 2 4 8 12 16 Cooler head unit Water heaterFurnace Dishwasher Service - see Sheet E1 Water Heater EC Verify existing power adequate for new furnace Exterior power locations to be confirmed with Tenant Sign internal lighting Remote pedistal with 50 amp WP plug for future possible food tru Jamb switches at Mech and Closet Extend conduit to site for future patio lighting Line of soffit for gas line and plumbing adjacent to wall 24"Wx12"D EC to rearrange lighting in bathroom with new fixture to be selected with Owner Improve existing outlet to GFI - or remove New soffit light New wall-mounted stair tread lights - see Section 1/A12 1 March 23, 2023 CO 1 Sheet NumberA16 Joseph E Calvin Date Sheet Title Electrical Power and Lighting Plans March 3, 2023 of 12 BE E 2 0 3 B U I L D I N G RE M O D E L 20 3 C l e a v e S t r e e t Es t e s P a r k , C O 8 0 5 1 7 Pr o j e c t : 2 2 2 4 – B E E 2 0 3 B U I L D I N G R E M O D E L F i l e : " 2 2 2 4 C D " M o d i fi e d : F r i , M a r 2 4 , 2 3 P r i n t : F r i , M a r 2 4 , 2 3 D r a w n b y : J E C C h e c k e d b y : R M C PO B o x 1 5 5 5 , E s t e s P a r k , C O 8 0 5 1 7 97 0 4 2 0 8 2 6 4 E2 of 2 Walter E Steige, PE