HomeMy WebLinkAboutPLANS Remodel 303 Green Pine Ct 2023-02-23RECOMMENDED TO FLOAT FLOORS IN BASEMENT WOOD IN CONTACT WITH CONCRETE IS TO TREATED OR OTHER APPROVED MATERIAL MINIMUM CEILING HEIGHT IN BASEMENT 7' MAINTAIN 30" OF WORKING CLEARANCE ON SERVICE SIDE OF GAS FUELED APPLIANCES COMBUSTION AIR REQUIRED TO GAS FUELED APPLIANCES ALL CIRCUITS TO BE ARC FAULT ALL OUTLETS TO BE TAMPER RESISTANT MAXIMUM OUTLET SPACING 12' 2015 IECC -75% OF LAMPS SHALL BE HIGH EFFICIENCY -ALL DUCT WORK LOCATED OUTSIDE THE THERMAL ENVELOPE SHALL BE TESTED FOR LEAKAGE General Notes: -All rooms to be AFCI except bath, utility and unfinished rooms -Bath, utility and unfinished rooms to be GFCI -Backwater valves to remain accessible -Back flow protect all below grade fixtures -1/2” dry wall req’d for enclosed usable space under stairs -Smoke alarms req’d in each sleeping room -Smoke/CO alarms req’d w/in 15’vicinity of bedroom exteriors -Min 1 emergency escape and rescue opening req’d per bedroom APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 02/23/2023 This structure must comply with the requirements of the 2020 National Electrical Code