HomeMy WebLinkAboutPLANS Remodel 566 Darcy Dr 2023-01-18Existing Photos at Workout Room and Unfinished Basement No Scale Float all walls with treated plates. (Recommended). 1/2" drywall under stairs if used for storage. All rooms to be AFCI except bath, utility, and unfinished rooms which will be GFCI. Backwater protection required at all basement level plumbing drains and to remain accessible. Minimum ceiling height 7'. All outlets to be tamper resistant. Maximum outlet spacing in finished rooms 12'. Minimum wall insulation R-15 continuous or R-19 cavity. Minimum 30" clearance at service side of appliances. Emergency egress windows per section R310. CO alarms per section R315. Smoke alarms per section R314. Draftstopping per section R302.12. Fireblocking per section R302.11. 30" clearance at water closet. Dryer exhaust per section M1502. This structure must comply with the requirements of the 2020 National Electrical Code REVIEWED by SAFEbuilt; 2018 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 01/18/2023 2015