HomeMy WebLinkAboutPLANS Remodel 271 W Riverside Dr 2023-01-272015 IECC
-75% OF LAMPS SHALL BE HIGH EFFICIENCY
-ALL DUCT WORK LOCATED OUTSIDE THE THERMAL
ENVELOPE SHALL BE TESTED FOR LEAKAGE
General Notes:
-Min (1) emergency escape and rescue opening req’d per
bedroom
-Glazing to be tempered per R308
-Min (1) programmable thermostat req’d
-Smoke alarm req’d in each sleeping room
-Smoke/CO alarm req’d w/in 15’ vicinity of bedroom exterior.
-Fireblock/Draftstop all chases and penetrations
EGRESS WINDOW
EGRESS WINDOW
AIR BARRIER
May require to be
tempered. Layout
not provided.
FAN
ALL CIRCUITS TO BE ARC FAULT
ALL OUTLETS TO BE TAMPER RESISTANT
MAXIMUM OUTLET SPACING 12'
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
01/27/2023
This structure must comply
with the requirements of the
2020 National Electrical Code
HVAC equipment including water heaters
must be located in a dedicated room.
Room(s) must be rated for one hour, all
sides.
Combustion air must be pulled directly from
the exterior. Cannot pull combustion air from
adjacent rooms, attics, crawlspaces, etc.
Appliances are prohibited from being
installed in uninhabitable spaces such as
attics and crawl spaces.
Hi Laura,
Our contractor did look at that, so if there is a way for the field inspector to just verify that when he has to go out, that would be great. Also, I received the second letter you just
sent over. We were hoping to change the size of that window in an early version of the design, but all windows in the house will be replaced with windows of the same size,
aside from the two that are being removed. I apologize for that confusion on the first floor plans I sent. We have already bought the new windows, and I've confirmed that the
window in the kitchen will be switched out with one that is the same size. The floor plan attached reflects that as well. Is that something we will need to resubmit still? We
would love to get things rolling as soon as possible. Thanks so much!
Kindly,
Madison Schneider
Assistant to David Sward
BTU'S not provided on existing
furnace see email below.
Inspector to verify in field that gas
line will work.
Approved
by
SAFEbuilt
01/27/2023
3:41:33 PM