HomeMy WebLinkAboutPLANS Single Family Residence 2081 Arapaho Rd 2022-11-161.0
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
11/16/2022
This structure must comply
with the requirements of the
2020 National Electrical Code
ALL ARCHITECTURAL PLANS, ENGINEERED PLANS,
SOILS REPORTS, TRUSS DRAWINGS, ENERGY CODE
REPORTS/RESCHECKS MUST BE ONSITE FOR
INSPECTORS REVIEW.
2.0
Approved
by
SAFEbuilt
11/16/2022
12:10:34 PM
3.0
Tempered glass
required
Tempered glass
required
?
Tempered glass
required
G2408.2 (305.3) Elevation of ignition source. Equipment
and appliances having an ignition source shall be elevated
such that the source of ignition is not less than 18 inches (457
mm) above the floor in hazardous locations and public
garages, private garages, repair garages, motor fuel-dispensing
facilities and parking garages. For the purpose of this section,
rooms or spaces that are not part of the living space of a
dwelling unit and that communicate directly with a private
garage through openings shall be considered to be part of the
private garage.
Exception: Elevation of the ignition source is not required
for appliances that are listed as flammable-vapor-ignition
resistant.
G2408.3 (305.5) Private garages. Appliances located in private
garages shall be installed with a minimum clearance of 6
feet (1829 mm) above the floor.
Exception: The requirements of this section shall not
apply where the appliances are protected from motor vehicle
impact and installed in accordance with Section
G2408.2.
Approved
by
SAFEbuilt
11/16/2022
12:10:34 PM
4.0
Approved
by
SAFEbuilt
11/16/2022
12:10:34 PM
5.0
R310.2 Emergency escape and rescue openings. Emergency
escape and rescue openings shall have minimum dimensions
as specified in this section.
R310.2.1 Minimum opening area. Emergency and
escape rescue openings shall have a net clear opening of
not less than 5.7 square feet (0.530 m2). The net clear
opening dimensions required by this section shall be
obtained by the normal operation of the emergency escape
and rescue opening from the inside. The net clear height
opening shall be not less than 24 inches (610 mm) and the
net clear width shall be not less than 20 inches (508 mm).
Exception: Grade floor or below grade openings shall
have a net clear opening of not less than 5 square feet
(0.465 m2).
R310.2.2 Window sill height. Where a window is provided
as the emergency escape and rescue opening, it shall
have a sill height of not more than 44 inches (1118 mm)
above the floor; where the sill height is below grade, it
shall be provided with a window well in accordance with
Section R310.2.3.
36" min
height
Approved
by
SAFEbuilt
11/16/2022
12:10:35 PM
G
S4
G
S4
C
S4
B
S4
H
S4
H
S4
H
S4
A
S4
A
S4
A
S4
A
S4
D
S4
F
S1
E
S1
A
S4
F
S1
X
TH
I
C
K
N
E
S
S
WIDTH
LE
N
G
T
H
XW TL
FO
U
N
D
A
T
I
O
N
P
L
A
N
PR
O
J
E
C
T
L
O
C
A
T
I
O
N
:
CL
I
E
N
T
:
CT
L
T
H
O
M
P
S
O
N
R408.4 Access. Access shall be provided to all under-floor
spaces. Access openings through the floor shall be a minimum
of 18 inches by 24 inches (457 mm by 610 mm). Openings
through a perimeter wall shall be not less than 16 inches
by 24 inches (407 mm by 610 mm). Where any portion of the
through-wall access is below grade, an areaway not less than
16 inches by 24 inches (407 mm by 610 mm) shall be provided.
The bottom of the areaway shall be below the threshold
of the access opening. Through wall access openings shall
not be located under a door to the residence. See Section
M1305.1.4 for access requirements where mechanical equipment
is located under floors.
Approved
by
SAFEbuilt
11/16/2022
12:10:35 PM
FR
A
M
I
N
G
S
C
H
E
M
A
T
I
C
PR
O
J
E
C
T
L
O
C
A
T
I
O
N
:
CL
I
E
N
T
:
CT
L
T
H
O
M
P
S
O
N
Approved
by
SAFEbuilt
11/16/2022
12:10:35 PM
1.
2.
3.
4.
5.
FR
A
M
I
N
G
S
C
H
E
M
A
T
I
C
PR
O
J
E
C
T
L
O
C
A
T
I
O
N
:
CL
I
E
N
T
:
CT
L
T
H
O
M
P
S
O
N
Approved
by
SAFEbuilt
11/16/2022
12:10:35 PM
A
S4
C
S4
D
S4
B
S4
E
S4
F
S4
G
S4
H
S4
FO
U
N
D
A
T
I
O
N
D
E
T
A
I
L
S
PR
O
J
E
C
T
L
O
C
A
T
I
O
N
:
CL
I
E
N
T
:
CT
L
T
H
O
M
P
S
O
N
Approved
by
SAFEbuilt
11/16/2022
12:10:35 PM