HomeMy WebLinkAboutPLANS Addition 1765 Olympian Ln 2022-12-08APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
12/08/2022
This structure must comply
with the requirements of the
2020 National Electrical Code
Code compliant landing required.
DATE: November 21, 2022
TO: Building Department
FROM: Frank E. Roberts, P.E.
RE: Storage Room Addition Foundation
1765 Olympian Lane
Estes Park, CO 80517
A new storage room addition is proposed adjacent to and attached to the existing
shop building (pole barn) at the above mentioned address. A design drawing
prepared by Macdonald & Associates detailing the storage room addition was
provided to me for specific review of the foundation interface between the existing
building and the proposed storage room addition. The foundation detail shows the
new storage room addition foundation slab doweled to the existing foundation slab.
This is necessary since the new storage room structure is attached to and supported
by the existing shop building structure. In my opinion, it is an acceptable detail in
regards to doweling the foundations together as long as both the existing shop and
new storage room are conditioned the same (heated or unheated) to ensure there
will not be differential movement between the foundations. My understanding is
and as noted on the design drawing both spaces are intended to be heated and
insulated.
If there are any questions, please do not hesitate to call me at 970-586-9388.
Sincerely,
Frank Roberts, P.E.
VAN HORN ENGINEERING AND SURVEYING
LAND SURVEYS
SUBDIVISIONS
DEVELOPMENT PLANNING
IMPROVEMENT PLATS
STRUCTURAL ENGINEERING
SANITARY ENGINEERING
MUNICIPAL ENGINEERING
1043 Fish Creek Road x Estes Park, Colorado 80517 x 970-586-9388 x E-mail: info@vanhornengineering.com
Sincerely,
Frank Roberts P E
11/21/2022
Approved
by
SAFEbuilt
12/08/2022
3:29:12 PM