Loading...
HomeMy WebLinkAboutPLANS Remodel 1081 Fall River Dr 2022-10-06PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND SITE PLAN REVIEWED FOR BUILDING COMPLIANCE - BY SAFEBUILT - PBLAND 1(: $'',7,21 6FDOH 3URMHFWQXPEHU 'DWH 'UDZQE\ &KHFNHGE\ $OGULFK%XLOGHUV *UDYHV$YH8QLW% (VWHV3DUN&2  )DOO5LYHU'ULYH (VWHV3DUN&2 0HWDO0HFKDQLFV,QF 6&OHYHODQG$YH /RYHODQG&2 WK$YH6WXGLRV VDUDK#WKDYHVWXGLRVFRP  9DQ+RUQ(QJLQHHULQJ 6XUYH\LQJ )LVK&UHHN5RDG (VWHV3DUN&2   *(1(5$/127(6    '9,(:6287+:(679,(: (;,67,1* 6+((7/,67 $ *(1(5$/127(6 $ 1(:&216758&7,21),567$1'6(&21')/2253/$1 $ %8,/',1*)5$0,1*6(&7,21$1')5$0,1*3/$1 $ )281'$7,216 $ '(02/,7,21),567$1'6(&21')/2253/$1 $ %8,/',1*(/(9$7,21(;,67,1*'(02/,7,216287+ $ %8,/',1*(/(9$7,211(:6287+$1':(67 $ %8,/',1*(/(9$7,211(:($67 $ ,17(5,25(/(9$7,216$1''(7$,/6 $ 5()/(&7('&(,/,1*3/$1)5$0,1*3/$1)281'$7,213/$1 $ '(&.3/$1 %8,/',1*&2'( ,17(51$7,21$/5(6,'(17,$/&2'( '(6,*1/2$'6 %8,/',1*'(6,*1&5,7(5,$ :,1'63(('03+(;32685(&6(&21'*8676 )/225/2$'/,9('($' )5267/,1('(37+,1&+(6 &/,0$7(=21()(1(675$7,21 6.</,*+7 */$=('&(,/,1*:22')5$0(0$66:$//59$/8()/22559/$8(%$6(0(17 6/$%&5$:/63$&(   6.. 6..0-$% $       '9,(:1257+($679,(: $'',7,21 352-(&76&23( 1(:$'',7,21210$,1/(9(/2)5(6,'(1&($'',7,21&216,6762)21(6725<1(: $'',7,21)$0,/<5220:,7+1(:%$7+5220$&&(6672(;,67,1*%('52201(: $'',7,21,6)8//<+($7('$1'&22/(',168/$7('$1'),1,6+(' '(02/,7,212)(;,67,1*63$&(&216,6762)5(029$/2)(;,67,1*:,1'2:6 5(029$/2)(;,67,1*:$//)251(:'225:$<5(029$/2)6,',1*72$&&20',$7( )25,17(5,25),1,6+(6$1'5(/2&$7,212)(;,67,1**$6/,1(721(:/2&$7,21 5(029$/$1'5(/2&$7,212)(;,67,1*(;+$8679(17 '(6,*1/2$'6 *5281'612:/2$' 36) $7 (/(9 522)612:/2$' 36) :,1'63(('9XOW PSK([S& 6(,60,&'(6,*1&$7(*25< % (1(5*<&2'( ,17(51$7,21$/(1(5*<&216(59$7,211(& 8)$&725 8)$&725 )(1(675$7,21 59$/8(:$//59$/8(59$/8(59$/8(:$//59$/8( 6+*& $1'0$5,1(1525K IW  1R 'HVFULSWLRQ 'DWH 3HUPLW6HW  5HYLVHG6HW  10/4/2022 STRUCTURAL PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND This structure must comply with the requirements of the 2020 National Electrical Code All work shall be performed by Licensed Contractors OR work shall be performed by the homeowner residing in the dwelling. Issuance of a permit or approval of these construction documents shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the adopted codes or of other ordinances of this jurisdiction. A permit presuming to give authority to violate or cancel the provisions of these codes shall be invalid. R105.4 PLANS AND CONSTRUCTION SHALL MEET THE 2015 IRC AND ALL APPLICABLE MUNICIPAL CODES & ORDINANCES ALL PERMIT DOCUMENTS: ARCHITECTURAL PLANS, ENGINEERED PLANS, SOILS REPORTS, TRUSS DRAWINGS, ENERGY CODE REPORTS/RESCHECKS, ETC... MUST BE KEPT TOGETHER & ONSITE FOR INSPECTORS REVIEW. Provide R-10 slab edge insulation for 2' from top of slab to 24" down. R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation r-value for slabs as indicated in table. The slab edge insluation for heated slabs shall not be required to extend below the slab. d. d. 2015 2020 NATIONAL ELECTRICAL CODE (NEC) ELECTRICAL CODE APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 10/06/2022 0.30 30 %('5220 &/ 2 6 ( 7 %$7+ )$0,/< $ $  $   $ 6LP .,7&+(1 ',1,1*:25.287 (;,67,1* '(&. &/26(7 $/ , * 1 $             1(:'(&. )$0,/<5220 $  %$7+5220       .(<127(6  (;7(5,25$:1,1*:,1'2:6  (;7(5,25'225  ,17(5,25:22''225$1':22')5$0(  6+2:(5+($'$1')$8&(7  32&.(7'225  6:,1*'225  '28%/(&/26(752':,7+833(56+(/9(23(1,1* 6+(/9,1*$7&/26(7(1'  (/(&75,&%$6(%2$5'+($7(5  0,1,63/,76((63(&,),&$7,216  3529,'(3523(5%/2&.,1*+($'(56)251(: '225:$<,1(;,67,1*:$//  79:$//02817('  (/(&75,&$/3$1(/6((63(&,),&$7,216  $77,&$&&(666((63(&,),&$7,216  +25,=217$/*5$%%$5  62/,'685)$&(%(1&+  +9$&9(17  9(57,&$/*5$%%$5  .1((:$//(;7(5,25:$//$6,1',&$7('  )8//+(,*+7,17(5,25)5$0(':$//  1(:6/,',1*:22'%<3$66&/26(7'225  5(&(66('&21&5(7(6/$%)256+2:(53$1  :22'32676833257)255,'*(%($0  5(&(66('+($7('7,/()/225,1*6<67(0  +$5'685)$&(/$1'6&$3,1*6$/9$*(' )520(;,67,1*6,'::$/.  72:(/%$5 1(::$//6         $/ , * 1           (1':$// 7,/()/225 :22'(1*,1((5(' )/225,1*       83 $   (;,67,1* '(&.                          $ %('5220 &/ 2 6 ( 7 %$ 7 + 5 2 2 0 /$ 8 1 ' 5 < +$//:$< %('5220 %('5220 &/26(7 &/26(7 1(::25.5(029( $1'5(3/$&(:,1'2:6 (;,67,1*(*5(66 :,1'2:6725(0$,1 6FDOH 3URMHFWQXPEHU 'DWH 'UDZQE\ &KHFNHGE\ $OGULFK%XLOGHUV *UDYHV$YH8QLW% (VWHV3DUN&2  )DOO5LYHU'ULYH (VWHV3DUN&2 0HWDO0HFKDQLFV,QF 6&OHYHODQG$YH /RYHODQG&2 WK$YH6WXGLRV VDUDK#WKDYHVWXGLRVFRP  9DQ+RUQ(QJLQHHULQJ 6XUYH\LQJ )LVK&UHHN5RDG (VWHV3DUN&2   1(: &216758&7,21 ),567$1'6(&21' )/2253/$1   0$,1/(9(/1(:  6.. 6..      833(5/(9(/1(:  6.. 6..0-$% $    1R 'HVFULSWLRQ 'DWH  5HYLVLRQ  3HUPLW6HW  5HYLVHG6HW  PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND Cement based substrate or equal on shower/tub walls - Typ Glazing installed in hazardous locations as defined in Section R308.4 shall be Tempered Glass Freeze Protect pipes per P2603.5 Fall Protection is required where applicable (R312) - Windows that are operable at 6' above grade with sill height lower than 24" Provide 50 cfm fan in bathroom - vented to exterior - when no natural ventilation is provided by window Fire Block shall be provided in enclosed wood framed walls per locations designated in R302.11 Access doors from Conditioned spaces to unconditioned spaces (E.G. Attics and Crawlspaces) shall be weatherstripped and insulated. Provide Anti-Scald valves on shower or tub/shower combination valves Showers shall be finished 72 inches above the floor with a non-absorbent material. Shower door minimum clear opening width is 24 inches and open outward Any New Gas piping shall be tested for not less than 15 min. @ 1 1/2 times the proposed maximum working pressure but not less than 10 psig. - before it is put into service. See section 2417.4.1 and local amendments Toilets & Lavatories shall be provided with a min. of 21 inches in front each fixture - each side of Toilets shall have 15 inches from the center line of the toilet and any sidewall or other obstructions. Provide attic access of min. of 22"x30" to enclosed attic space of combustible roof construction with a vertical height of 30" Provide Air Barrier & insulation on exterior wall at shower/tub, etc... See Air Barrier table N1102.4.1.1 Exhaust Air from bathrooms & toilet rooms shall not be recirculated within the residence or other dwelling units and be exhausted directly outside Do not remove Manufacturers stickers on windows until after all final inspections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rovide R-10 slab edge insulation for 2' from top of slab to 24" down. R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation r-value for slabs as indicated in table. The slab edge insluation for heated slabs shall not be required to extend below the slab. 2' - 0 " be l o w g r a d e Insulation exposed shall have a rigid, opaque and weather-resistant protective covering to prevent degradation. Shall cover the exposed exterior insulation and extend not less than 6" below grade Per Section R806.5 - Unvented enclosed roof framing assemblies - shall be permitted if all conditions are met: 1. attic space is completely within the building thermal envelope 2. Interior Class I vapor retarders are not installed on the ceiling side of the unvented attic assembly or enclosed roof framing assembly. 3. Where wood shakes or shingles are used, a minimum 1/4" vented airspace separates the shingles and roofing underlayment above sheathing. 4. In climate zones 5,6,7&8, any air-impermeable insulation shall be a Class II vapor retarder, or shall have a Class II vapor retarder coating or covering in direct contact with the underside of the insulation. 5. Insulation shall be located in accordance below: 5.1 Item 5.1.1, 5.1.2, 5.1.3, 5.1.4 shall be met, depending on the air permeability of the insulation directly under the structural roof sheathing. 5.1.1 Where only air-impermeable insulation is provided, it shall be direct contact with the underside of the structural roof sheathing. 5.1.2 Where air-permeable insulation is provided inside the building thermal envelope, it shall be installed in accordance with Section 5.1.1. In addition to the air-permeable insulation installed directly below the structural sheathing, rigid board or sheet insulation shall be installed directly above the structural roof sheathing in accordance with the R-values in Table R806.5 for condensation control 5.1.3 Where both air-impermeable and air-permeable insulation are provided, the air-impermeable insulation shall be applied in direct contact with the underside of the structural roof sheathing in accordance with item 5.1.1 and shall be in accordance with the R-values in Table R806.5 for condensation control. The air permeable insulation shall be installed directly under the air-impermeable insulation. 5.1.4 Alternatively, sufficient rigid board or sheet insulation shall be installed directly above the structural roof sheathing to maintain the monthly average temperature of the underside of the structural roof sheathing above 45 deg. F. For calculation purposes, an interior air temperature of 68 deg.F is assumed and the exterior air temperature is assumed to be the monthly average outside air temperature of the three coldest months. 5.2 Where preformed insulation board is used as the air-impermeable insulation layer, it shall be sealed at the perimeter of each individual sheet interior surface to form a continuous layer.2015 PRESCRIPTIVE INSULATION VALUES: SLAB-ON-GRADE = R-10 for 2 ft. FLOOR = R-30 WALLS = R-20 or R-13+R-5 continuous ATTIC/CEILING = R-49 FENESTRATION U-FACTOR VALUE: WINDOWS = 0.32 Prescriptive/Performance path(s) must follow Section N1101 through N1104 of Chapter 11 of the 2015 IRC PRESCRIPTIVE INSULATION VALUES ARE MINIMUM CODE REQUIREMENTS - YOU ARE ALWAYS ALLOWED TO INCREASE THESE VALUES PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND ;721*8( *5229(6,',1* ;)227,1* %(/2:)5267'(37+ 9(57#2&: +22. ',$;/21* $1&+25%2/76: (0%('#2& '$033522),1* 9$3255(7$5'(5 ,62/$7,21-2,17&$8/.(' $1'6(/$(' 6($/$17 721*8($1'*5229( )/225,1* 0$7&+(;,67,1* 9(57,&$/6,',1* &21&5(7(:$// )227,1*%(/2: )5267'(37+  &217 9(57#2& ',$;/21* $1&+25%2/76: (0%('#2& :$7(53522),1* 9$3255(7$5'(5 (;3$16,21-2,17 &$8/.('$1'6(/$(' 6($/$17 &21&5(7(6/$% 721*8($1'*5229( )/225,1* :22'%$6( :22'&$3 '5<:$// ;.1((:$// 5$'213,3,1* 3(5,0(7(5 )281'$7,21'5$,1 5$'213,3,1* 3(5,0(7(5 )281'$7,21'5$,1 :22'%$6( 5,*,' ,168/$7,21 &21&5(7(6/$% ;::0 *5$9(/21  :(('%$55,(5 *5$9(/21  :(('%$55,(5 +25,=217$/2& 26% +286(:5$3 ;::0 )281'$7,21'(7$,/)281'$7,21'(7$,/ 0,1%(/2: ),1$/*5$'(6/23('$:$< )520)281'$7,216:$/( )25'5$,1$*( 6($/$17 5%$77 ,168/$7,21 ;:$// 6($/$17 5 )2$0%2$5' 5%$77 ,168/$7,21 5 )2$0%2$5' 5,*,',168/$7,21 +25,=#2& $'',7,21$/:$//'5$,1 :+(5(%$&.),//+(,*+7 $%29()227,1*(;&(('6   *5$9(/+(,*+7 )227,1* '2:(/6:+22.  63/,&(#2& )8 / /  + ( , * + 7  , 1 7 ( 5 , 2 5  ) 5 $ 0 ( '  : $ / /  , 1  & / 2 6 ( 7            0 D [   &217 (;326(' &21&5(7(    % ( / 2 :  * 5 $ ' ( .1((:$//:635$<)2$0 5,168/$7,21          6FDOH 3URMHFWQXPEHU 'DWH 'UDZQE\ &KHFNHGE\ $OGULFK%XLOGHUV *UDYHV$YH8QLW% (VWHV3DUN&2  )DOO5LYHU'ULYH (VWHV3DUN&2 0HWDO0HFKDQLFV,QF 6&OHYHODQG$YH /RYHODQG&2 WK$YH6WXGLRV VDUDK#WKDYHVWXGLRVFRP  9DQ+RUQ(QJLQHHULQJ 6XUYH\LQJ )LVK&UHHN5RDG (VWHV3DUN&2   )281'$7,216   1(:&216758&7,21)281'$7,21   6.. 6..      6.. 6..0-$% $    1R 'HVFULSWLRQ 'DWH 3HUPLW6HW  5HYLVHG6HW  10/4/2022 STRUCTURAL PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND Provide R-10 slab edge insulation for 2' from top of slab to 24" down. R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation r-value for slabs as indicated in table. The slab edge insluation for heated slabs shall not be required to extend below the slab. Insulation exposed shall have a rigid, opaque and weather-resistant protective covering to prevent degradation. Shall cover the exposed exterior insulation and extend not less than 6" below grade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ield Copy Print out legibly & in color and have on site for inspector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ield Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND        (;,67,1*%8,/',1* $'',7,21        (;,67,1**5$'(%$&. ),//('721(:$'',7,21 72  3 , 7 & +          352326('*5$'( 7232))/225      (;,67,1* $'',7,21 (;,67,1* *5$'(%$&. ),//('721(: $'',7,21  7232))/225 67(3 +$5'685)$&( &5,&.(7 522) +$5'685)$&( 67$,56 6FDOH 3URMHFWQXPEHU 'DWH 'UDZQE\ &KHFNHGE\ $OGULFK%XLOGHUV *UDYHV$YH8QLW% (VWHV3DUN&2  )DOO5LYHU'ULYH (VWHV3DUN&2 0HWDO0HFKDQLFV,QF 6&OHYHODQG$YH /RYHODQG&2 WK$YH6WXGLRV VDUDK#WKDYHVWXGLRVFRP  9DQ+RUQ(QJLQHHULQJ 6XUYH\LQJ )LVK&UHHN5RDG (VWHV3DUN&2   %8,/',1* (/(9$7,211(: 6287+$1':(67   %8,/',1*(/(9$7,211(::(67   %8,/',1*(/(9$7,211(:6287+   6.. 6..0-$% $    .(<127(6  1(:522)3,7&+720$7&+(;,67,1*0$7(5,$/720$7&+ (;,67,1*  1(:$:1,1*:,1'2:  12786('  1(:'(&.&217,18('2))2)(;,67,1*67</(',0(16,216 6+$//0$7&+(;,67,1*  5(/2&$7('9(17  %$&.),//('*5$'(/(9(/$71(:67$,56  1(:(;7(5,25'225  5(/2&$7('+26(  (;7(5,25/,*+7),;785(  1(::,1'2:6+$//%(,167$//(',1/2&$7,212)(;,67,1* $'-867('6,=(5(48,5(0(17672$&&2002'$7()25522) 3,7&+3$7&+$61(('('  1(:&5,&.(7522) 1R 'HVFULSWLRQ 'DWH  5HYLVLRQ  3HUPLW6HW  5HYLVHG6HW  PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND General Elevation Notes: - Asphalt shingles shall meet 175 mph wind-speed & be tested in accordance with ASTM D 7158 & packaging shall bear label of classification - All asphalt shingles shall be installed per manufacturers installation instructions (R905.2.4) - Siding Coverings to meet 175 MPH wind-speed - All stone, stucco and siding to have a barrier underneath at exterior walls - Roof slopes from 2:12 up to 4:12 require double underlayment - Sills less than 24" - w/72+" of fall require fall protection - Roof Ventilation per R806 - All stairs, landings, guards, rails and walking surfaces to comply with R311 and R312 - All Exterior Coverings shall comply with R703 - All Roofing materials shall comply with R905 - Water-resistive barrier required per R703.2 - Drip edge required on all rakes and eaves ESTES PARK - ICE BARRIER REQUIREMENTS: An ice barrier, such as a self-adhering polymer modified bitumen sheet, shall be installed on the entire area of roof slopes from two units vertical in 12 units horizontal (17-percent slope), up to four units vertical in 12 units horizontal (33-percent slope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ield Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND $                               &251(5%(1&+ +25,=217$/ *5$%%$5 6+2:(53$1$5($5(&(66(' &21&5(7()/225,17(*5$/ +($7('7,/()/2256 6+(/9($1' '28%/(+$1*,1* 52' 23(1,1*6+(/9,1* 9(57,&$/ *5$%%$5               ,17(*5$/ +($7('7,/( )/2256 6FDOH 3URMHFWQXPEHU 'DWH 'UDZQE\ &KHFNHGE\ $OGULFK%XLOGHUV *UDYHV$YH8QLW% (VWHV3DUN&2  )DOO5LYHU'ULYH (VWHV3DUN&2 0HWDO0HFKDQLFV,QF 6&OHYHODQG$YH /RYHODQG&2 WK$YH6WXGLRV VDUDK#WKDYHVWXGLRVFRP  9DQ+RUQ(QJLQHHULQJ 6XUYH\LQJ )LVK&UHHN5RDG (VWHV3DUN&2   ,17(5,25 (/(9$7,216$1' '(7$,/6    ,17(5,25(/(9$7,21+$//:$< (;,67,1*,1721(:    %$7+5220,17(5,25(/(9$7,21 1257+    %$7+5220,17(5,25(/(9$7,21 ($67   %$7+5220:(67   6.. 6..0-$% $       (1/$5*(')/2253/$11(: %$7+5220 1R 'HVFULSWLRQ 'DWH  5HYLVLRQ  3HUPLW6HW  5HYLVHG6HW  PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND '1 :22'%($0 '5<:$//&(,/,1* 29(5+($' /,*+7,1* #  #  #  6/23(' '5<:$// &(,/,1* 6/23(' '5<:$// &(,/,1* // / / / / / / / / / / / / / / / / /5(&(66('&$1/,*+7',00$%/( / 5(&(66('%$7+5220(;+$867 :,7+5281'/('3$1(//,*+7),;785( / 5(&(66('6+2:(5:(75$7(' 6+2:(5/,*+7),;785( / 5(&(66('&$1/,*+7)256/23('  &(,/,1*',00$%/( &) &(,/,1*)$1,167$//216/23( // &) %$6(%2$5' +($7 6:,))$1/7&20%2  32&.(7'225 $77,&   32&.(7'225 5,'*(  /9/           5)3,5$)7(56 # 2&:5%$77 ,168/$7,21 ;326725   ;678'3$&. 3267  ;0,1,080 ;29(5 )5$0(522) &5,&.(7 (;,67,1*:$//; (;,67,1*522) 6/23(6/23( 6/23(6/23( ;7+,&.3$'   %$56($&+:$<&/5 )520%27720'5,//$1' (32;<,172(;,67 )281'$7,21(0%('0(17 %$56 )281'$7,21'(7$,/ )52673527(&7,21 )227,1*67(36$6 1(('(')25)5267 )281'$7,21:$// 5$'215,6(59(17 72(;7(5,25 (;,67,1* )281'$7,21 $&&(6672(;,67,1* (/(&75,&$/3$1(/ :$7(56(:(5$1' :$7(5+($7(5 (;,67,1**$5$*(%(/2: 3267 (; , 6 7 , 1 *  )2 8 1 ' $ 7 , 2 1 (;,67,1*)281'$7,21 3267 )281'$7,21 '(7$,/ )281'$7,21 '(7$,/ '5$,1$*(3$7+ '(&.3,(5 ',$; 67(3,1723 2))281'$7,21 67(3,1723 2))281'$7,21 )281'$7,21 '(7$,/ 5(&(66&21&5(7( 6/$%)25 6+2:(53$1                                              ;)5$0(':$//217232) &21&5(7()281'$7,21:$// 75($7('/('*(5;)$67(5 72)281'$7,21:,7+7,7$1 6&5(:6 2& )$67(11(::$//72 (;,67,1*:$//: 7,0%(5/2.6#2& $1'675$36 $  ; :$// ;:$// $//:,1'2:6 ;+'56  -6  .6 ;+($'(5 '225+($'(5  -6  .6 ;678'3$&.)25 5,'*(%($0%27+(1'6 ;:$// .1((:$//; 5,'*(%($0 3267 3267725,'*( (;,67,1* 3$175< ;326725   ;678'3$&.3529,'(+($'(5,1 (;,67,1*:$//)25 1(:32&.(7'225 3529,'(+($'(5,1(;,67,1* :$//)251(:32&.(7'225 ;:$// + + + + ++ + 6FDOH 3URMHFWQXPEHU 'DWH 'UDZQE\ &KHFNHGE\ $OGULFK%XLOGHUV *UDYHV$YH8QLW% (VWHV3DUN&2  )DOO5LYHU'ULYH (VWHV3DUN&2 0HWDO0HFKDQLFV,QF 6&OHYHODQG$YH /RYHODQG&2 WK$YH6WXGLRV VDUDK#WKDYHVWXGLRVFRP  9DQ+RUQ(QJLQHHULQJ 6XUYH\LQJ )LVK&UHHN5RDG (VWHV3DUN&2   5()/(&7('&(,/,1* 3/$1)5$0,1* 3/$1)281'$7,21 3/$1    ),567)/2251(:&216758&7,21 (/(&75,&$/$1'/,*+7,1*3/$1    522)1(:&216758&7,21)5$0,1* 3/$1   6.. 6..0-$% $      ),567)/225)281'$7,213/$1   0$,1/(9(/)5$0,1*3/$1 1R 'HVFULSWLRQ 'DWH  5HYLVLRQ  3HUPLW6HW  5HYLVHG6HW  10/4/2022 STRUCTURAL PERMIT #22-EP-00646 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND This structure must comply with the requirements of the 2020 National Electrical Code Closet lights to conform to E4003.12 Bathrooms - Min one - 20 amp circuit - bathroom countertops or similar work surfaces shall be GFCI protected - Typical for each bathroom (2020 NEC 210.8) IC Rated Sealed Recess Cans in Attic Outdoor receptacles shall be a min 12" from final grade, roof surfaces or similar locations. Provide Tamper-resistant receptacles - Installed Per E4002.14 Outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas and similar rooms or areas shall be AFCI protected - per E3902.16 A minimum of 75% of the lamps in permanently installed lighting fixtures shall be high efficacy lamps. per 2015 N1104.1 The entire building must be provided with Smoke Detectors one in each sleeping room, outside each sleeping room and on each additional story of the dwelling - CO Detectors are Required outside of bedrooms and within 15' of bedroom doors. Receptacles cannot be installed within a zone of 3' horizontally & 8' from the bathtub rim or shower stall threshold (410.10D - 2020 NEC) See 410.10 (D) for new requirements for where and what type of fixtures can be installed in areas containing bathtubs/showers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ield Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND Min. Stair, Handrail & Guardrail Requirements (R311.7 - R312): 1. Stairways to be not less than 36" in width 2. Risers = 7 3/4" max 3. Treads = 10" min. 4. The length of Run and the height of Riser shall not vary more than 3/8" in the entire run of the stair. 5. Stairs are required to be illuminated 6. Open risers opening = less than 4" 7. Nosing = 3/4" min. 8. Guardrail required for over 30" 9. Guardrail openings = less than 4" 10. Guardrail to meet 200lb. uniform live load 11. Handrail reqd for 4 or more risers 12. Handrail = 34" min. - 38" max 13. Handrail to be continuous one side min. 14. Hand-grip = 1-1/4" min to 2" max 15. Handrails to return to wall, post or terminal Plastic composite decking, treads and handrail to comply with R507.2.2 & ASTM D7032. Verify composite decking can span the required joist spacing