HomeMy WebLinkAboutPLANS New SFD 175 Curry Dr 2021-04-28Date Rcvd: _________________ Sub-Contractors: 1 2 3 4 5 Sprinkler: Yes No ____Gas ____Roof ___Solar ___Other 970-577-3726 building@estes.org Description: Town of Estes Park Suite 230 Department of Building Safety 170 MacGregor Ave Estes Park CO, 80517 Permit #: __________________ App Exp: ___________________ Permit Exp: ________________ Rcvd by: ___________________ IMPORTANT - COMPLETE ALL ITEMS AND MARK ALL APPLICABLE ITEMS BUILDING PERMIT APPLICATION Email: Property Owner: Name Phone Email Primary Contractor: Other: ____________________ Crawlspace: _______________ Decks: ____________________ _____Other # of Bedrooms: ________ # Full Bath: ________ # 1/2 Bath:____ #3/4 Bath: ____ ____Other Square Footage New or Tenant Finish Only Residential _____One Family _____Multi-Family: Main Flr: __________________ Add Flrs: __________________ Basement: ________________ Building Official Signature: __________________________________________ Date: ____________ Date: ____________ Notes: Email: ____Windows ____Fireplace ____Plumbing ____Mechanical Construction Type ____Wood ____Structural Steel ____Masonry ________Sign Occupancy Classification: _____________ ________New Building Attached/Detached _____Basement: Partial/Full Finished/Unfinished _____Fireplace Miscellaneous # of Units: _________________ _____Hotel, Motel, Dormitory: Job Site Address: Phone: Phone: Contact Name: Valuation: _________________ Total Fees: _________________ Applicant Signature: _______________________________________________ Construction Type: _________ Separated/Non-Seperated ____Grading Demolition Site Plan: _________________ State Permit: ______________ Asbestos Permit: ___________ Commercial ________Shell Only ________Tenant Finish ________Remodel/Addition # of Units ___________________ _____Garage Attached/Detached _____Patio Covered Porch: ____________ Garage: ___________________ 572 505 2015 IECC section R402.4.4 Appliances must be direct vent (combustion and exhaust) or the mechanical equipment must be located within a room entirely isolated from the rest of the buildings thermal envelope in accordance with R402.4.4 ROOF VENTILATION PER R806 ALL DECK MATERIAL TO BE TREATED, NATURALLY DURABLE, OR OTHER APPROVED MATERIAL WITH APPROVED HANGERS, BRACKETS, AND FASTENERS. PROVIDE ENGINEERS STAMPED TRUSS SHEETS FOR INSPECTION HOUSE WRAP REQUIRED MIN 36" LANDING GLAZING TO BE TEMPERED PER R308 Roof assemblies shall be applied in accordance with chapter 9 of 2018 IRC and manufacturer’s installation instructions GENERAL NOTES ALL ELEVATION: -ALL STONE, STUCCO AND SIDING TO HAVE BARRIER UNDERNEATH AT EXTERIOR WALLS -ROOF SLOPES FROM 2:12 UP TO 4:12 REQUIRE DOUBLE UNDERLAYMENT -SILLS LESS THEN 24" WITH 72"+ OF FALL REQUIRE FALL PROTECTION -ALL STAIRS, LANDINGS, GUARDS, RAILS, AND WALKING SURFACES MUST COMPLY WITH R311 AND R312 THIS STRUCTURE MUST CONFORM TO THE 2020 NATIONAL ELECTRICAL CODE SAFE built APPROVED Subject to Inspection and Compliance to all relevant Adopted Building Codes Changes to Plans must be approved DATE_______ BY_________ CODE___________________2015 IRC 2015 IECC 4/28/21 Dori Wataha SOFFITS (EAVES) WITHIN 5 FT SETBACK SHALL BE PROTECTED WITH FIRE RESISTANT MATERIALS. NO OPENINGS ALLOWEDRim joist shall have an air barrier on the interior between each joist. All irrigation sprinklers taps shall be protected by an approved back flow device. All architectural plans, engineered foundation plans, soils reports, truss drawings, energy code report or ResCheck must be onsite for inspections. 2015 I-CODES Reviewed by SAFEbuilt Reviewed by SAFEbuilt WATER HAMMER ARRESTORS TO BE INSTALLED WHERE QUICK CLOSING VALVES ARE UTILIZED PER. MANUFACTURERS SPECS. AIR BARRIER REQUIRED FIREBLOCKING / DRAFTSTOP FAN FAN GFCI GFCI OUTLETS REQUIRED PER WALL SPACING GFCI MAX DRYER DUCT LENGTH 35' SUBTRACT 5' FOR EVER 90 DEGREES AND 2.5' FOR EVERY 45 DEGREES. LANDINGS, STAIRS, GUARDS AND RAILS PER R311 & R312 EGRESS WINDOW ALL OUTLETS GFCI PROVIDE ONE PROGRAMMABLE THERMOSTAT. SD SD SD/COD AIR BARRIER REQUIRED AIR BARRIER REQUIRED GLAZING TO BE TEMPERED PER R308 WINDOWS WITH A FINISHED SILL HEIGHT OF LESS THAN 24" ABOVE FLOOR SHALL HAVE AN APPROVED GUARD OR OTHER APPROVED FALL PROTECTION Insulation per Energy Docs: BG Walls: R-21 AG Walls: R-19 Ceiling: R-38 Windows: U-0.25 Reviewed by SAFEbuilt WINDOWS WITH A FINISHED SILL HEIGHT OF LESS THAN 24" ABOVE FLOOR SHALL HAVE AN APPROVED GUARD OR OTHER APPROVED FALL PROTECTION Insulation per Energy Docs: BG Walls: R-21 AG Walls: R-19 Ceiling: R-38 Windows: U-0.25 SDSD/COD GFCI FAN AIR BARRIER REQUIRED LANDINGS, STAIRS, GUARDS AND RAILS PER R311 & R312 EGRESS WINDOW Reviewed by SAFEbuilt Insulation per Energy Docs: BG Walls: R-21 AG Walls: R-19 Ceiling: R-38 Windows: U-0.25 1/2" DRYWALL REQUIRED FOR ENCLOSED USABLE SPACES UNDER STAIRS SD/COD COMBUSTION AIR REQUIRED (1 HIGH; 1 LOW) MAINTAIN ALL REQUIRED CLEARANCES TO GAS APPLIANCES LANDINGS, STAIRS, GUARDS AND RAILS PER R311 & R312 Per IRC Section R302.13, Fire Protection of Floors is Required MIN. 18" X 24" CRAWLSPACE ACCESS ATTACH COPY OF ENERGY COMPLIANCE TO ELECTRICAL PANEL 20-MINUTE RATED DOOR SELF CLOSING AND WEATHER STRIPPED ALL OUTLETS GFCI Reviewed by SAFEbuilt STAIRWAY NOTES (Typ. all stairs): 1.Stairways shall be not less than 36” in width. 2.Stairway rises shall be not greater than 7 ¾” 3.Stairways treads shall have a minimum run of 10” 4.The length of run and the height of riser shall not vary more than 3/8” in the entire run of the stair. 5.Stairs are req’d to be illuminated. 6.Open risers are permitted if the opening is less than 4” 7.Min ¾” nosing 8.Guardrail is required if height is over 30” 9.Open guardrails and open handrails on decks and stairways more than 30” above grade or a floor below shall have members spaced so that a 4” diameter sphere cannot pass through HANDRAIL NOTES: 1.Handrail shall be continuous on at least one side of stairs with 4 or more risers 2.Handrails shall be placed not less than 34 inches nor more than 38 inches above stair nosing’s 3.The hand-grip portion of the handrails shall be not less than 1 ¼” nor more than 2” in circular cross section. 4.Handrails shall be placed not less than 1 ½” from any wall or other surface. 5.Handrails to be returned to wall, post or safety terminal. J S4 G S4 D S4 A S4 B S4 I S4 K S4 ∅ ∅ F S4 I sim S4 C S4 A S4 H S4 L S4 E S4 E S4 M S4 FO U N D A T I O N P L A N PR O J E C T L O C A T I O N : CL I E N T : CT L T H O M P S O N SAFEbuilt APPROVED Subject to Inspection and Compliance to all relevant Adopted Building Codes Changes to Plans must be approved DATE_______ BY_________ CODE___________________ Dori Wataha4/28/21 2015 IRC *OPEN HOLE INSPECTION REQUIRED *ENGINEERED STAMPED LETTERS OF INSPECTION REQUIRED *UNDERGROUND INSPECTION REQUIRED SHEAR WALL INSPECTION REQUIRED FOR ALL NOTED INTERIOR AND EXTERIOR WALLS 1.2.3.4.5. FRAMING SCHEMATIC PROJECT LOCATION:CLIENT:CTL THOMPSON 1.2.3.4.5. FRAMING SCHEMATIC PROJECT LOCATION:CLIENT:CTL THOMPSON H S4 B S4 A S4 F S4 G S4 K S4 J S4 C S4 I S4 D S4 E S4 L S4 M S4 FO U N D A T I O N D E T A I L S PR O J E C T L O C A T I O N : CL I E N T : CT L T H O M P S O N 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:Equipment Summary Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Base System: Cooling: none Heating: Armstrong ARMSTRONG AIR A96UH2E030B08*-* Water Heating: Gas conventional40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Investment 1: Cooling: Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0 Heating:Input = 0 Btuh, Output = 0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Reviewed by SAFEbuilt 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 2 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:Equipment Summary Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Investment 2: Cooling:Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0 Heating: Input = 0 Btuh, Output = 0 Btuh, 80 AFUE Water Heating: Gas conventional40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Investment 3: Cooling: Coil Model: Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0 Heating:Input = 0 Btuh, Output = 0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Reviewed by SAFEbuilt 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:Manual S Compliance Report Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Cooling Equipment Design Conditions °F0Entering coil DB:Btuh14992Sensible gain:°F91.0Outdoor design DB: °F0Entering coil WB:Btuh0Latent gain:°F60.5Outdoor design WB: Btuh14992Total gain:°F75.0Indoor design DB: cfm849Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Equipment type: Model:Manufacturer: cfm849Actual airflow: % of load0Btuh0Sensible capacity: % of load0Btuh0Latent capacity: %0SHR:% of load0Btuh0Total capacity: Heating Equipment Design Conditions °F57.4Entering coil DB:Btuh37719Heat loss:°F4.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Gas furnaceEquipment type: A96UH2E030B08*-*Model:ArmstrongManufacturer: cfm527Actual airflow: °F68Temp. rise:% of load77Btuh29000Output capacity: Meets all requirements of ACCA Manual S. Reviewed by SAFEbuilt 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:DHW Report for Base System Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Design Criteria Not occupied during the dayOccupants DishwasherNumberAge Clothes washer00-5 0Additional use (gpd)26-13 120Setpoint (°F)214-59 61Daily use (gpd)060+ Gas conventional (40 gal, 0.60 EF) 40Tank size (gal)Manufacturer 0.60Energy factorTrade name 0.0Input (MBtuh)Model 601st hour (gal)AHRI ref. number 77Recovery eff. (%) Reviewed by SAFEbuilt 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 2 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:DHW Report for Investment 1 Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Design Criteria Not occupied during the dayOccupants DishwasherNumberAge Clothes washer00-5 0Additional use (gpd)26-13 120Setpoint (°F)214-59 61Daily use (gpd)060+ Gas conventional (40 gal, 0.60 EF) 40Tank size (gal)Manufacturer 0.60Energy factorTrade name 0.0Input (MBtuh)Model 601st hour (gal)AHRI ref. number 77Recovery eff. (%) Reviewed by SAFEbuilt 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 3 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:DHW Report for Investment 2 Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Design Criteria Not occupied during the dayOccupants DishwasherNumberAge Clothes washer00-5 0Additional use (gpd)26-13 120Setpoint (°F)214-59 61Daily use (gpd)060+ Gas conventional (40 gal, 0.60 EF) 40Tank size (gal)Manufacturer 0.60Energy factorTrade name 0.0Input (MBtuh)Model 601st hour (gal)AHRI ref. number 77Recovery eff. (%) Reviewed by SAFEbuilt 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 4 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:DHW Report for Investment 3 Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Design Criteria Not occupied during the dayOccupants DishwasherNumberAge Clothes washer00-5 0Additional use (gpd)26-13 120Setpoint (°F)214-59 61Daily use (gpd)060+ Gas conventional (40 gal, 0.60 EF) 40Tank size (gal)Manufacturer 0.60Energy factorTrade name 0.0Input (MBtuh)Model 601st hour (gal)AHRI ref. number 77Recovery eff. (%) Reviewed by SAFEbuilt Right-Suite® Universal 2021 21.0.02 RSU15394 Form RPER 1 15 Mar 09 Residential Plans Examiner Review Form for HVAC System Design (Loads, Equipment, Ducts) Header Information Contractor: ATTACHEDREQUIRED ATTACHMENTSJohnson Construction NoYesManual J1 Form (and supporting worksheets):Roy Johnson Mechanical license:NoYesor MJ1AE Form* (and supporting worksheets): NoYesOEM performance data (heating, cooling, blower): Building plan #:NoYesManual D Friction Rate Worksheet: NoYesDuct distribution sketch: Home address (Street or Lot#, Block, Subdivision):175 Curry Drive, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Front Door faces NorthBuildingWinter Design Conditions North, East, West, South, Northeast, Northwest, Southeast, SouthwestOrientation:°F4Outdoor temperature: °F70Indoor temperature: 0Number of bedrooms:Btuh37719Total heat loss: ft²2296Conditioned floor area: 4Number of occupants:Summer Design Conditions °F91Outdoor temperature: Windows°F75Indoor temperature: ft0Eave overhang depth:% RH50gr/lb @-30Grains difference: Blinds, drapes, etc. noneInternal shade:Btuh15616Sensible heat gain: Btuh0Latent heat gain: 0Number of skylights:Btuh15616Total heat gain: HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Blower Data Cooling Equipment Data 527Heating cfm: Air Conditioner, Heat pump, etc. Equipment type: Furnace, Heat pump, Boiler, etc. Gas furnaceEquipment type: 849Cooling cfm: Fan's rated external static pressure for design airflow in H2O0.50Static pressure:Model:ArmstrongModel: A96UH2E030B08*-* Btuh0Total cooling capacity:Heat pumps - capacity at winter design outdoor conditions Btuh29000Heating output capacity: Btuh0Sensible cooling capacity: Btuh0Latent cooling capacity:Btuh0Aux. heating output capacity: HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Duct Materials Usedft0Longest supply duct:cfm849Design airflow: Trunk duct:ft67Longest return duct:in H2O0.50Equipment design ESP: ft67Total effective length (TEL):in H2O0Total device pressure losses: Sheet metal, Round flex vinylBranch duct:Friction Rate = ASP ÷ (TEL x 100)in/100ft0.745Friction rate:in H2O0.50Available static pressure (ASP): I declare the load calculation, equipment, equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County, Town Municipality or Authority having jurisdiction use. *Home qualifies for MJ1AE Form based on Abridged Edition Checklist Reviewed by SAFEbuilt Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:Load Short Form Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO Design Information InfiltrationClgHtg SimplifiedMethod914Outside db (°F) AverageConstruction quality7570Inside db (°F) 1 (Average)Fireplaces1666Design TD (°F) H-Daily range 5030Inside humidity (%) -3037Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Armstrong Make n/a Trade ARMSTRONG AIR Trade n/a Model A96UH2E030B08*-* Cond n/a AHRI ref 201710533 Coil n/a AHRI ref n/a Efficiency 96 AFUE Efficiency n/a Heating input Btuh30000 Sensible cooling Btuh0 Heating output Btuh29000 Latent cooling Btuh0 Temperature rise °F68 Total cooling Btuh0 Actual air flow cfm527 Actual air flow cfm849 Air flow factor cfm/Btuh0.016 Air flow factor cfm/Btuh0.062 Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Living open above 165 3652 1718 59 106 Kitchen 180 1314 1311 21 81 Dining 156 2502 1212 41 75 Stairways 174 546 85 9 5 Powder 35 335 49 5 3 Laundry 63 1180 229 19 14 Entry 77 1899 469 31 29 Masterbath 90 1992 967 32 60 Master 310 4274 1678 69 104 Entryway 182 1559 277 25 17 Stairway 96 1932 862 31 53 Bathroom 60 505 128 8 8 Bedroom 3 368 6258 2336 102 145 Hallway 52 2831 2115 46 131 Reviewed by SAFEbuilt Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 2 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N Open to below 0 0 0 0 0 Room21 192 845 145 14 9 bath1 96 824 131 13 8 Entire House d 2296 32448 13714 527 849 Other equip loads 5271 1278 Equip. @ 0.96 RSM 14392 Latent cooling 0 TOTALS 2296 37719 14392 527 849 Reviewed by SAFEbuilt Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:Project Summary Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor:175 Curry Drive, Estes Park, CO Notes: Design Information Fort Collins (AWOS), CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F4 Outside db °F91Inside db °F70 Inside db °F75 Design TD °F66 Design TD °F16Daily range H Relative humidity %50Moisture difference gr/lb-30 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh32448 Structure Btuh13714 Ducts Btuh0 Ducts Btuh0Central vent (99 cfm) 5271 Btuh Central vent (99 cfm) Btuh1278 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh37719 Use manufacturer's data n Rate/swing multiplier 0.96InfiltrationEquipment sensible load Btuh14392 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average1 (Average)Fireplaces Structure Btuh-412 Ducts Btuh0Central vent (99 cfm) Btuh-1468 CoolingHeating Outside air22962296Area (ft²) Equipment latent load Btuh0 2331923319Volume (ft³)Air changes/hour 0.210.46 Equipment Total Load (Sen+Lat)Btuh14392 Equiv. AVF (cfm) 82179 Req. total capacity at 0.70 SHR ton1.7 Heating Equipment Summary Cooling Equipment Summary Make Armstrong Make n/aTrade ARMSTRONG AIR Trade n/a Model A96UH2E030B08*-* Cond n/aAHRI ref 201710533 Coil n/a AHRI ref n/aEfficiency 96 AFUE Efficiency n/a Heating input Btuh30000 Sensible cooling Btuh0Heating output Btuh29000 Latent cooling Btuh0 Temperature rise °F68 Total cooling Btuh0Actual air flow cfm527 Actual air flow cfm849 Air flow factor cfm/Btuh0.016 Air flow factor cfm/Btuh0.062Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 1.00 Reviewed by SAFEbuilt Job #: 115-15-20 Performed by sb for: Roy Johnson 175 Curry Drive Estes Park, CO Johnson Construction Estes Park, CO Scale: 1 : 111 Page 1 Right-Suite® Universal 2021 21.0.02 RSU15394 2021-Mar-01 14:47:48 ...\Roy Johnson 175 Curry Drive.rup N Upper Level Stairway Bathroom Bedroom 3 Hallway Open to below 8 cfm 53 cfm 72 cfm 72 cfm jdeeney@comcast.net> 131 cfm Reviewed by SAFEbuilt Job #: 115-15-20 Performed by sb for: Roy Johnson 175 Curry Drive Estes Park, CO Johnson Construction Estes Park, CO Scale: 1 : 111 Page 2 Right-Suite® Universal 2021 21.0.02 RSU15394 2021-Mar-01 14:47:48 ...\Roy Johnson 175 Curry Drive.rup N Main Level Living open above Kitchen Dining Stairways Powder Laundry Entry Masterbath Master Room21 bath1 52'-6" 11'-0"106 cfm 75 cfm 31 cfm 19 cfm 81 cfm 9 cfm 5 cfm 849 cfm 104 cfm 14 cfm 13 cfm 16 " 60 cfm Reviewed by SAFEbuilt Job #: 115-15-20 Performed by sb for: Roy Johnson 175 Curry Drive Estes Park, CO Johnson Construction Estes Park, CO Scale: 1 : 111 Page 3 Right-Suite® Universal 2021 21.0.02 RSU15394 2021-Mar-01 14:47:48 ...\Roy Johnson 175 Curry Drive.rup N Basement GarageCrawlspace EntrywayMechanical 25 cfm Reviewed by SAFEbuilt Bold/italic values have been manually overridden 2021-Mar-01 14:46:29 Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1 ...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N 115-15-20Job:Duct System Summary Jan 21, 2021Date:Entire House sbBy: Johnson Construction Estes Park, CO Project Information Roy Johnson, Johnson ConstructionFor: 175 Curry Drive, Estes Park, CO CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0.10 Available static pressure in H2O0.50in H2O0.40 Supply / return available pressure 0.200 / 0.200 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.745in/100ft0.596 Actual air flow cfm849cfm527 Total effective length (TEL) ft67 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00ShMt0x00088128hBathroom 00ShMt0x00072511168cBedroom 3 00ShMt0x00072511168cBedroom 3-A 00ShMt0x00075411212cDining 00ShMt0x0002931469hEntry 00VlFx0x0001725277hEntryway 00ShMt0x000131462115cHallway 00ShMt0x00081211311cKitchen 00ShMt0x0001419229hLaundry 00ShMt0x000106591718cLiving open above 00ShMt0x000104691678cMaster 00ShMt0x0006032967cMasterbath 00ShMt0x0003549hPowder 00ShMt0x000914145hRoom21 00ShMt0x0005331862cStairway 00ShMt0x0005985hStairways 00ShMt0x000813131hbath1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 5270 849 67.1 0.745 608 16.0 x0 0 ShMt Reviewed by SAFEbuilt REScheck Software Version 4.6.2 Compliance Certificate Project 175 Curry Dr Energy Code:2015 IECC Location:Estes Park, Colorado Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:2,500 ft2 Glazing Area 6% Climate Zone:5 (7944 HDD) Permit Date: Construction Site: 175 Curry Drive Estes Park, CO 80517 Owner/Agent: Roy or Michele Johnson Mountainview Vacations, LLC 742 Lakewood Court Estes Park, CO 80517 970-222-2622 mjohnson830@msn.com Designer/Contractor: Permit Number: Compliance: Passes using UA trade-off 13.9% Better Than Code Maximum UA:361 Your UA:311 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1,700 49.0 0.0 0.026 44 Wall 1: Wood Frame, 16" o.c.277 21.0 0.0 0.057 15 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5 Wall 2: Wood Frame, 16" o.c.216 21.0 0.0 0.057 12 Wall 3: Wood Frame, 16" o.c.277 21.0 0.0 0.057 12 Window 5: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5 Window 6: Vinyl/Fiberglass Frame:Double Pane with Low-E 14 0.250 4 Window 7: Vinyl/Fiberglass Frame:Double Pane with Low-E 14 0.250 4 Window 8: Vinyl/Fiberglass Frame:Double Pane with Low-E 14 0.250 4 Wall 4: Wood Frame, 16" o.c.252 21.0 0.0 0.057 14 Wall 5: Wood Frame, 16" o.c.621 21.0 0.0 0.057 35 Wall 6: Wood Frame, 16" o.c.216 21.0 0.0 0.057 11 Window 11: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.250 4 Window 12: Vinyl/Fiberglass Frame:Double Pane with Low-E 8 0.250 2 Wall 7: Wood Frame, 16" o.c.621 21.0 0.0 0.057 25 Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 1 of 10 04/21/21Report date: Reviewed by SAFEbuilt Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Window 13: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5 Window 14: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5 Window 15: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5 Door 1: Solid 41 0.170 7 Door 2: Solid 41 0.170 7 Door 3: Solid 41 0.170 7 Wall 8: Wood Frame, 16" o.c.216 21.0 0.0 0.057 12 Wall 9: Wood Frame, 16" o.c.328 21.0 0.0 0.057 18 Window 16: Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.250 2 Window 17: Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.250 2 Crawl 1: Solid Concrete or Masonry Wall height: 3.0' Depth below grade: 2.6' Insulation depth: 3.0' 621 19.0 0.0 0.054 27 Crawl 2: Solid Concrete or Masonry Wall height: 3.0' Depth below grade: 2.6' Insulation depth: 3.0' 217 19.0 0.0 0.054 9 Crawl 3: Solid Concrete or Masonry Wall height: 3.0' Depth below grade: 2.6' Insulation depth: 3.0' 216 19.0 0.0 0.054 9 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 2 of 10 04/21/21Report date: Reviewed by SAFEbuilt Inspection Checklist Requirements: 41.0% were addressed directly in the REScheck software REScheck Software Version 4.6.2 Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable Requirement will be met. 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 3 of 10 04/21/21Report date: Reviewed by SAFEbuilt Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.2.11 [FO7]1 Unvented crawl space wall insulation R-value. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO8]1 Unvented crawl space wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.11 [FO9]1 Unvented crawl space continuous vapor retarder installed over exposed earth, joints overlapped by 6 in. and sealed, extending at least 6 in. up and attached to the wall. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.11 [FO10]1 Unvented crawl space wall insulation depth of burial or distance from top of wall. _____ in._____ in.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 4 of 10 04/21/21Report date: Reviewed by SAFEbuilt Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.3.6, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.2.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable 403.3.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 5 of 10 04/21/21Report date: Reviewed by SAFEbuilt Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 6 of 10 04/21/21Report date: Reviewed by SAFEbuilt Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 7 of 10 04/21/21Report date: Reviewed by SAFEbuilt Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value.R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ACH 50 =_____Complies Does Not Not Observable Not Applicable Requirement will be met. 403.2.3 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 8 of 10 04/21/21Report date: Reviewed by SAFEbuilt Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 9 of 10 04/21/21Report date: Reviewed by SAFEbuilt Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 401.3 [FI7]2 Compliance certificate posted.Complies Does Not Not Observable Not Applicable Requirement will be met. 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 175 Curry Dr Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 10 of 10 04/21/21Report date: Reviewed by SAFEbuilt 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 21.00Above-Grade Wall 19.00Below-Grade Wall 0.00Floor 49.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.25Window 0.17Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments Reviewed by SAFEbuilt