HomeMy WebLinkAboutPLANS New SFD 175 Curry Dr 2021-04-28Date Rcvd: _________________
Sub-Contractors:
1
2
3
4
5
Sprinkler: Yes No
____Gas
____Roof
___Solar
___Other
970-577-3726
building@estes.org
Description:
Town of Estes Park
Suite 230
Department of Building Safety
170 MacGregor Ave
Estes Park CO, 80517
Permit #: __________________
App Exp: ___________________
Permit Exp: ________________
Rcvd by: ___________________
IMPORTANT - COMPLETE ALL ITEMS AND MARK ALL APPLICABLE ITEMS
BUILDING PERMIT APPLICATION
Email:
Property Owner:
Name Phone Email
Primary Contractor:
Other: ____________________
Crawlspace: _______________
Decks: ____________________
_____Other
# of Bedrooms: ________
# Full Bath: ________
# 1/2 Bath:____ #3/4 Bath: ____
____Other
Square Footage New or Tenant Finish Only
Residential
_____One Family
_____Multi-Family:
Main Flr: __________________
Add Flrs: __________________
Basement: ________________
Building Official Signature: __________________________________________
Date: ____________
Date: ____________
Notes:
Email:
____Windows
____Fireplace
____Plumbing
____Mechanical Construction Type
____Wood
____Structural Steel
____Masonry
________Sign
Occupancy
Classification: _____________
________New Building
Attached/Detached
_____Basement: Partial/Full
Finished/Unfinished
_____Fireplace
Miscellaneous
# of Units: _________________
_____Hotel, Motel, Dormitory:
Job Site Address:
Phone:
Phone:
Contact Name:
Valuation: _________________
Total Fees: _________________
Applicant Signature: _______________________________________________
Construction Type: _________
Separated/Non-Seperated
____Grading
Demolition
Site Plan: _________________
State Permit: ______________
Asbestos Permit: ___________
Commercial
________Shell Only
________Tenant Finish
________Remodel/Addition
# of Units ___________________
_____Garage
Attached/Detached
_____Patio
Covered Porch: ____________
Garage: ___________________
572
505
2015 IECC section R402.4.4
Appliances must be direct vent (combustion and exhaust) or the mechanical
equipment must be located within a room entirely isolated from the rest of the
buildings thermal envelope in accordance with R402.4.4
ROOF VENTILATION PER R806
ALL DECK MATERIAL TO BE TREATED, NATURALLY DURABLE, OR
OTHER APPROVED MATERIAL WITH APPROVED HANGERS,
BRACKETS, AND FASTENERS.
PROVIDE ENGINEERS STAMPED TRUSS SHEETS
FOR INSPECTION
HOUSE WRAP REQUIRED
MIN 36" LANDING
GLAZING TO BE TEMPERED PER R308
Roof assemblies shall be applied in accordance with chapter 9 of
2018 IRC and manufacturer’s installation instructions
GENERAL NOTES ALL ELEVATION:
-ALL STONE, STUCCO AND SIDING TO HAVE BARRIER UNDERNEATH AT EXTERIOR WALLS
-ROOF SLOPES FROM 2:12 UP TO 4:12 REQUIRE DOUBLE UNDERLAYMENT
-SILLS LESS THEN 24" WITH 72"+ OF FALL REQUIRE FALL PROTECTION
-ALL STAIRS, LANDINGS, GUARDS, RAILS, AND WALKING SURFACES MUST COMPLY WITH R311 AND R312
THIS STRUCTURE MUST CONFORM TO
THE 2020 NATIONAL ELECTRICAL CODE
SAFE built
APPROVED
Subject to Inspection and Compliance
to all relevant Adopted Building Codes
Changes to Plans must be approved
DATE_______ BY_________
CODE___________________2015 IRC 2015 IECC
4/28/21 Dori Wataha
SOFFITS (EAVES) WITHIN 5 FT SETBACK SHALL BE PROTECTED WITH
FIRE RESISTANT MATERIALS. NO OPENINGS ALLOWEDRim joist shall have an air
barrier on the interior
between each joist.
All irrigation sprinklers taps
shall be protected by an
approved back flow device.
All architectural plans,
engineered foundation
plans, soils reports, truss
drawings, energy code
report or ResCheck must be
onsite for inspections.
2015 I-CODES
Reviewed by
SAFEbuilt
Reviewed by
SAFEbuilt
WATER HAMMER ARRESTORS TO BE INSTALLED
WHERE QUICK CLOSING VALVES ARE UTILIZED
PER. MANUFACTURERS SPECS.
AIR BARRIER REQUIRED
FIREBLOCKING / DRAFTSTOP
FAN
FAN
GFCI
GFCI
OUTLETS REQUIRED PER WALL SPACING
GFCI
MAX DRYER DUCT LENGTH 35'
SUBTRACT 5' FOR EVER 90 DEGREES AND
2.5' FOR EVERY 45 DEGREES.
LANDINGS, STAIRS, GUARDS
AND RAILS PER R311 & R312
EGRESS WINDOW
ALL OUTLETS GFCI
PROVIDE ONE PROGRAMMABLE THERMOSTAT.
SD
SD
SD/COD
AIR BARRIER REQUIRED
AIR BARRIER REQUIRED
GLAZING TO BE TEMPERED PER R308
WINDOWS WITH A FINISHED SILL HEIGHT OF LESS THAN 24" ABOVE
FLOOR SHALL HAVE AN APPROVED GUARD OR OTHER APPROVED
FALL PROTECTION
Insulation per Energy Docs:
BG Walls: R-21
AG Walls: R-19
Ceiling: R-38
Windows: U-0.25
Reviewed by
SAFEbuilt
WINDOWS WITH A FINISHED SILL HEIGHT OF LESS THAN 24" ABOVE
FLOOR SHALL HAVE AN APPROVED GUARD OR OTHER APPROVED
FALL PROTECTION
Insulation per Energy Docs:
BG Walls: R-21
AG Walls: R-19
Ceiling: R-38
Windows: U-0.25
SDSD/COD
GFCI
FAN
AIR BARRIER REQUIRED
LANDINGS, STAIRS, GUARDS AND RAILS PER R311 & R312
EGRESS WINDOW
Reviewed by
SAFEbuilt
Insulation per Energy Docs:
BG Walls: R-21
AG Walls: R-19
Ceiling: R-38
Windows: U-0.25
1/2" DRYWALL REQUIRED
FOR ENCLOSED USABLE
SPACES UNDER STAIRS
SD/COD
COMBUSTION AIR REQUIRED
(1 HIGH; 1 LOW)
MAINTAIN ALL REQUIRED
CLEARANCES TO GAS
APPLIANCES
LANDINGS, STAIRS, GUARDS AND RAILS PER R311 & R312
Per IRC Section R302.13, Fire Protection of Floors is Required
MIN. 18" X 24"
CRAWLSPACE
ACCESS ATTACH COPY OF
ENERGY COMPLIANCE
TO ELECTRICAL PANEL
20-MINUTE RATED DOOR SELF CLOSING
AND WEATHER STRIPPED
ALL OUTLETS GFCI
Reviewed by
SAFEbuilt
STAIRWAY NOTES (Typ. all stairs):
1.Stairways shall be not less than 36” in width.
2.Stairway rises shall be not greater than 7 ¾”
3.Stairways treads shall have a minimum run of 10”
4.The length of run and the height of riser shall not vary more than 3/8” in the entire run of the stair.
5.Stairs are req’d to be illuminated.
6.Open risers are permitted if the opening is less than 4”
7.Min ¾” nosing
8.Guardrail is required if height is over 30”
9.Open guardrails and open handrails on decks and stairways more than 30” above grade or a floor below shall
have members spaced so that a 4” diameter sphere cannot pass through
HANDRAIL NOTES:
1.Handrail shall be continuous on at least one side of stairs with 4 or more risers
2.Handrails shall be placed not less than 34 inches nor more than 38 inches above stair nosing’s
3.The hand-grip portion of the handrails shall be not less than 1 ¼” nor more than 2” in circular cross section.
4.Handrails shall be placed not less than 1 ½” from any wall or other surface.
5.Handrails to be returned to wall, post or safety terminal.
J
S4
G
S4
D
S4
A
S4
B
S4
I
S4
K
S4
∅
∅
F
S4
I sim
S4
C
S4
A
S4
H
S4
L
S4
E
S4
E
S4
M
S4
FO
U
N
D
A
T
I
O
N
P
L
A
N
PR
O
J
E
C
T
L
O
C
A
T
I
O
N
:
CL
I
E
N
T
:
CT
L
T
H
O
M
P
S
O
N
SAFEbuilt
APPROVED
Subject to Inspection and Compliance
to all relevant Adopted Building Codes
Changes to Plans must be approved
DATE_______ BY_________
CODE___________________
Dori Wataha4/28/21
2015 IRC
*OPEN HOLE INSPECTION REQUIRED
*ENGINEERED STAMPED LETTERS OF INSPECTION REQUIRED
*UNDERGROUND INSPECTION REQUIRED
SHEAR WALL INSPECTION REQUIRED FOR ALL
NOTED INTERIOR AND EXTERIOR WALLS
1.2.3.4.5.
FRAMING SCHEMATIC PROJECT LOCATION:CLIENT:CTL THOMPSON
1.2.3.4.5.
FRAMING SCHEMATIC PROJECT LOCATION:CLIENT:CTL THOMPSON
H
S4
B
S4
A
S4
F
S4
G
S4
K
S4 J
S4
C
S4
I
S4
D
S4
E
S4
L
S4
M
S4
FO
U
N
D
A
T
I
O
N
D
E
T
A
I
L
S
PR
O
J
E
C
T
L
O
C
A
T
I
O
N
:
CL
I
E
N
T
:
CT
L
T
H
O
M
P
S
O
N
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:Equipment Summary Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Base System:
Cooling: none
Heating: Armstrong ARMSTRONG AIR A96UH2E030B08*-*
Water Heating: Gas conventional40 gal tank, 36 MBtuh input, 0.60 EF
Warranties:
Features:
Investment 1:
Cooling:
Coil Model:
Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0
Heating:Input = 0 Btuh, Output = 0 Btuh, 80 AFUE
Water Heating: Gas conventional
40 gal tank, 36 MBtuh input, 0.60 EF
Warranties:
Features:
Reviewed by
SAFEbuilt
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 2
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:Equipment Summary Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Investment 2:
Cooling:Coil Model:
Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0
Heating:
Input = 0 Btuh, Output = 0 Btuh, 80 AFUE
Water Heating: Gas conventional40 gal tank, 36 MBtuh input, 0.60 EF
Warranties:
Features:
Investment 3:
Cooling:
Coil Model:
Total cooling capacity = 0 Btuh, 0 SEER, Sound Level = 0.0
Heating:Input = 0 Btuh, Output = 0 Btuh, 80 AFUE
Water Heating: Gas conventional
40 gal tank, 36 MBtuh input, 0.60 EF
Warranties:
Features:
Reviewed by
SAFEbuilt
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:Manual S Compliance Report Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Cooling Equipment
Design Conditions
°F0Entering coil DB:Btuh14992Sensible gain:°F91.0Outdoor design DB:
°F0Entering coil WB:Btuh0Latent gain:°F60.5Outdoor design WB:
Btuh14992Total gain:°F75.0Indoor design DB:
cfm849Estimated airflow:%50Indoor RH:
Manufacturer's Performance Data at Actual Design Conditions
Equipment type:
Model:Manufacturer:
cfm849Actual airflow:
% of load0Btuh0Sensible capacity:
% of load0Btuh0Latent capacity:
%0SHR:% of load0Btuh0Total capacity:
Heating Equipment
Design Conditions
°F57.4Entering coil DB:Btuh37719Heat loss:°F4.0Outdoor design DB:
°F70.0Indoor design DB:
Manufacturer's Performance Data at Actual Design Conditions
Gas furnaceEquipment type:
A96UH2E030B08*-*Model:ArmstrongManufacturer:
cfm527Actual airflow:
°F68Temp. rise:% of load77Btuh29000Output capacity:
Meets all requirements of ACCA Manual S.
Reviewed by
SAFEbuilt
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:DHW Report for Base System Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Design Criteria
Not occupied during the dayOccupants
DishwasherNumberAge
Clothes washer00-5
0Additional use (gpd)26-13
120Setpoint (°F)214-59
61Daily use (gpd)060+
Gas conventional (40 gal, 0.60 EF)
40Tank size (gal)Manufacturer
0.60Energy factorTrade name
0.0Input (MBtuh)Model
601st hour (gal)AHRI ref. number
77Recovery eff. (%)
Reviewed by
SAFEbuilt
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 2
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:DHW Report for Investment 1 Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Design Criteria
Not occupied during the dayOccupants
DishwasherNumberAge
Clothes washer00-5
0Additional use (gpd)26-13
120Setpoint (°F)214-59
61Daily use (gpd)060+
Gas conventional (40 gal, 0.60 EF)
40Tank size (gal)Manufacturer
0.60Energy factorTrade name
0.0Input (MBtuh)Model
601st hour (gal)AHRI ref. number
77Recovery eff. (%)
Reviewed by
SAFEbuilt
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 3
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:DHW Report for Investment 2 Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Design Criteria
Not occupied during the dayOccupants
DishwasherNumberAge
Clothes washer00-5
0Additional use (gpd)26-13
120Setpoint (°F)214-59
61Daily use (gpd)060+
Gas conventional (40 gal, 0.60 EF)
40Tank size (gal)Manufacturer
0.60Energy factorTrade name
0.0Input (MBtuh)Model
601st hour (gal)AHRI ref. number
77Recovery eff. (%)
Reviewed by
SAFEbuilt
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 4
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:DHW Report for Investment 3 Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Design Criteria
Not occupied during the dayOccupants
DishwasherNumberAge
Clothes washer00-5
0Additional use (gpd)26-13
120Setpoint (°F)214-59
61Daily use (gpd)060+
Gas conventional (40 gal, 0.60 EF)
40Tank size (gal)Manufacturer
0.60Energy factorTrade name
0.0Input (MBtuh)Model
601st hour (gal)AHRI ref. number
77Recovery eff. (%)
Reviewed by
SAFEbuilt
Right-Suite® Universal 2021 21.0.02 RSU15394
Form
RPER 1
15 Mar 09
Residential Plans Examiner Review Form
for HVAC System Design (Loads, Equipment, Ducts)
Header Information
Contractor: ATTACHEDREQUIRED ATTACHMENTSJohnson Construction
NoYesManual J1 Form (and supporting worksheets):Roy Johnson
Mechanical license:NoYesor MJ1AE Form* (and supporting worksheets):
NoYesOEM performance data (heating, cooling, blower):
Building plan #:NoYesManual D Friction Rate Worksheet:
NoYesDuct distribution sketch:
Home address (Street or Lot#, Block, Subdivision):175 Curry Drive, Entire House
HVAC LOAD CALCULATION (IRC M1401.3)
Design Conditions Building Construction Information
Front Door faces NorthBuildingWinter Design Conditions
North, East, West, South, Northeast, Northwest, Southeast, SouthwestOrientation:°F4Outdoor temperature:
°F70Indoor temperature:
0Number of bedrooms:Btuh37719Total heat loss:
ft²2296Conditioned floor area:
4Number of occupants:Summer Design Conditions
°F91Outdoor temperature:
Windows°F75Indoor temperature:
ft0Eave overhang depth:% RH50gr/lb @-30Grains difference:
Blinds, drapes, etc.
noneInternal shade:Btuh15616Sensible heat gain:
Btuh0Latent heat gain:
0Number of skylights:Btuh15616Total heat gain:
HVAC EQUIPMENT SELECTION (IRC M1401.3)
Heating Equipment Data Blower Data Cooling Equipment Data
527Heating cfm:
Air Conditioner, Heat pump, etc.
Equipment type:
Furnace, Heat pump, Boiler, etc.
Gas furnaceEquipment type:
849Cooling cfm:
Fan's rated external static pressure for design
airflow
in H2O0.50Static pressure:Model:ArmstrongModel:
A96UH2E030B08*-*
Btuh0Total cooling capacity:Heat pumps - capacity at winter design outdoor conditions Btuh29000Heating output capacity:
Btuh0Sensible cooling capacity:
Btuh0Latent cooling capacity:Btuh0Aux. heating output capacity:
HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1)
Duct Materials Usedft0Longest supply duct:cfm849Design airflow:
Trunk duct:ft67Longest return duct:in H2O0.50Equipment design ESP:
ft67Total effective length (TEL):in H2O0Total device pressure losses:
Sheet metal, Round flex vinylBranch duct:Friction Rate = ASP ÷ (TEL x 100)in/100ft0.745Friction rate:in H2O0.50Available static pressure (ASP):
I declare the load calculation, equipment, equipment selection and duct design were rigorously performed based on the building plan listed above. I
understand the claims made on these forms will be subject to review and verification.
Contractor's printed name:
Contractor's signature: Date:
Reserved for County, Town Municipality or Authority having jurisdiction use.
*Home qualifies for MJ1AE Form based on Abridged Edition Checklist
Reviewed by
SAFEbuilt
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:Load Short Form Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
Design Information
InfiltrationClgHtg
SimplifiedMethod914Outside db (°F)
AverageConstruction quality7570Inside db (°F)
1 (Average)Fireplaces1666Design TD (°F)
H-Daily range
5030Inside humidity (%)
-3037Moisture difference (gr/lb)
HEATING EQUIPMENT COOLING EQUIPMENT
Make Armstrong Make n/a
Trade ARMSTRONG AIR Trade n/a
Model A96UH2E030B08*-* Cond n/a
AHRI ref 201710533 Coil n/a
AHRI ref n/a
Efficiency 96 AFUE Efficiency n/a
Heating input Btuh30000 Sensible cooling Btuh0
Heating output Btuh29000 Latent cooling Btuh0
Temperature rise °F68 Total cooling Btuh0
Actual air flow cfm527 Actual air flow cfm849
Air flow factor cfm/Btuh0.016 Air flow factor cfm/Btuh0.062
Static pressure in H2O0.50 Static pressure in H2O0.50
Space thermostat Load sensible heat ratio 1.00
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft²)(Btuh)(Btuh)(cfm)(cfm)
Living open above 165 3652 1718 59 106
Kitchen 180 1314 1311 21 81
Dining 156 2502 1212 41 75
Stairways 174 546 85 9 5
Powder 35 335 49 5 3
Laundry 63 1180 229 19 14
Entry 77 1899 469 31 29
Masterbath 90 1992 967 32 60
Master 310 4274 1678 69 104
Entryway 182 1559 277 25 17
Stairway 96 1932 862 31 53
Bathroom 60 505 128 8 8
Bedroom 3 368 6258 2336 102 145
Hallway 52 2831 2115 46 131
Reviewed by
SAFEbuilt
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 2
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
Open to below 0 0 0 0 0
Room21 192 845 145 14 9
bath1 96 824 131 13 8
Entire House d 2296 32448 13714 527 849
Other equip loads 5271 1278
Equip. @ 0.96 RSM 14392
Latent cooling 0
TOTALS 2296 37719 14392 527 849
Reviewed by
SAFEbuilt
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:Project Summary Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:175 Curry Drive, Estes Park, CO
Notes:
Design Information
Fort Collins (AWOS), CO, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F4 Outside db °F91Inside db °F70 Inside db °F75
Design TD °F66 Design TD °F16Daily range H
Relative humidity %50Moisture difference gr/lb-30
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh32448 Structure Btuh13714
Ducts Btuh0 Ducts Btuh0Central vent (99 cfm) 5271 Btuh Central vent (99 cfm) Btuh1278
Outside air Outside airHumidification Btuh0 Blower Btuh0
Piping Btuh0Equipment load Btuh37719 Use manufacturer's data n
Rate/swing multiplier 0.96InfiltrationEquipment sensible load Btuh14392
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average1 (Average)Fireplaces Structure Btuh-412
Ducts Btuh0Central vent (99 cfm) Btuh-1468
CoolingHeating Outside air22962296Area (ft²) Equipment latent load Btuh0
2331923319Volume (ft³)Air changes/hour 0.210.46 Equipment Total Load (Sen+Lat)Btuh14392
Equiv. AVF (cfm) 82179 Req. total capacity at 0.70 SHR ton1.7
Heating Equipment Summary Cooling Equipment Summary
Make Armstrong Make n/aTrade ARMSTRONG AIR Trade n/a
Model A96UH2E030B08*-* Cond n/aAHRI ref 201710533 Coil n/a
AHRI ref n/aEfficiency 96 AFUE Efficiency n/a
Heating input Btuh30000 Sensible cooling Btuh0Heating output Btuh29000 Latent cooling Btuh0
Temperature rise °F68 Total cooling Btuh0Actual air flow cfm527 Actual air flow cfm849
Air flow factor cfm/Btuh0.016 Air flow factor cfm/Btuh0.062Static pressure in H2O0.50 Static pressure in H2O0.50
Space thermostat Load sensible heat ratio 1.00
Reviewed by
SAFEbuilt
Job #: 115-15-20
Performed by sb for:
Roy Johnson
175 Curry Drive
Estes Park, CO
Johnson Construction
Estes Park, CO
Scale: 1 : 111
Page 1
Right-Suite® Universal 2021
21.0.02 RSU15394
2021-Mar-01 14:47:48
...\Roy Johnson 175 Curry Drive.rup
N
Upper Level
Stairway Bathroom
Bedroom 3
Hallway
Open to below
8 cfm
53 cfm
72 cfm
72 cfm
jdeeney@comcast.net>
131 cfm
Reviewed by
SAFEbuilt
Job #: 115-15-20
Performed by sb for:
Roy Johnson
175 Curry Drive
Estes Park, CO
Johnson Construction
Estes Park, CO
Scale: 1 : 111
Page 2
Right-Suite® Universal 2021
21.0.02 RSU15394
2021-Mar-01 14:47:48
...\Roy Johnson 175 Curry Drive.rup
N
Main Level
Living open above
Kitchen
Dining
Stairways
Powder
Laundry
Entry
Masterbath
Master
Room21
bath1
52'-6"
11'-0"106 cfm
75 cfm
31 cfm
19 cfm 81 cfm 9 cfm 5 cfm
849 cfm
104 cfm
14 cfm
13 cfm
16 "
60 cfm
Reviewed by
SAFEbuilt
Job #: 115-15-20
Performed by sb for:
Roy Johnson
175 Curry Drive
Estes Park, CO
Johnson Construction
Estes Park, CO
Scale: 1 : 111
Page 3
Right-Suite® Universal 2021
21.0.02 RSU15394
2021-Mar-01 14:47:48
...\Roy Johnson 175 Curry Drive.rup
N
Basement
GarageCrawlspace
EntrywayMechanical
25 cfm
Reviewed by
SAFEbuilt
Bold/italic values have been manually overridden
2021-Mar-01 14:46:29
Right-Suite® Universal 2021 21.0.02 RSU15394 Page 1
...son Curry Drive\Roy Johnson 175 Curry Drive.rup Calc = MJ8 Front Door faces: N
115-15-20Job:Duct System Summary Jan 21, 2021Date:Entire House sbBy:
Johnson Construction
Estes Park, CO
Project Information
Roy Johnson, Johnson ConstructionFor:
175 Curry Drive, Estes Park, CO
CoolingHeating
External static pressure in H2O0.50in H2O0.50
Pressure losses in H2O0in H2O0.10
Available static pressure in H2O0.50in H2O0.40
Supply / return available pressure 0.200 / 0.200 in H2O in H2O0.250 / 0.250
Lowest friction rate in/100ft0.745in/100ft0.596
Actual air flow cfm849cfm527
Total effective length (TEL) ft67
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk
00ShMt0x00088128hBathroom
00ShMt0x00072511168cBedroom 3
00ShMt0x00072511168cBedroom 3-A
00ShMt0x00075411212cDining
00ShMt0x0002931469hEntry
00VlFx0x0001725277hEntryway
00ShMt0x000131462115cHallway
00ShMt0x00081211311cKitchen
00ShMt0x0001419229hLaundry
00ShMt0x000106591718cLiving open above
00ShMt0x000104691678cMaster
00ShMt0x0006032967cMasterbath
00ShMt0x0003549hPowder
00ShMt0x000914145hRoom21
00ShMt0x0005331862cStairway
00ShMt0x0005985hStairways
00ShMt0x000813131hbath1
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk
rb1 0x 5270 849 67.1 0.745 608 16.0 x0 0 ShMt
Reviewed by
SAFEbuilt
REScheck Software Version 4.6.2
Compliance Certificate
Project 175 Curry Dr
Energy Code:2015 IECC
Location:Estes Park, Colorado
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:2,500 ft2
Glazing Area 6%
Climate Zone:5 (7944 HDD)
Permit Date:
Construction Site:
175 Curry Drive
Estes Park, CO 80517
Owner/Agent:
Roy or Michele Johnson
Mountainview Vacations, LLC
742 Lakewood Court
Estes Park, CO 80517
970-222-2622
mjohnson830@msn.com
Designer/Contractor:
Permit Number:
Compliance: Passes using UA trade-off
13.9% Better Than Code Maximum UA:361 Your UA:311
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 1,700 49.0 0.0 0.026 44
Wall 1: Wood Frame, 16" o.c.277 21.0 0.0 0.057 15
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5
Wall 2: Wood Frame, 16" o.c.216 21.0 0.0 0.057 12
Wall 3: Wood Frame, 16" o.c.277 21.0 0.0 0.057 12
Window 5: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5
Window 6: Vinyl/Fiberglass Frame:Double Pane with Low-E 14 0.250 4
Window 7: Vinyl/Fiberglass Frame:Double Pane with Low-E 14 0.250 4
Window 8: Vinyl/Fiberglass Frame:Double Pane with Low-E 14 0.250 4
Wall 4: Wood Frame, 16" o.c.252 21.0 0.0 0.057 14
Wall 5: Wood Frame, 16" o.c.621 21.0 0.0 0.057 35
Wall 6: Wood Frame, 16" o.c.216 21.0 0.0 0.057 11
Window 11: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.250 4
Window 12: Vinyl/Fiberglass Frame:Double Pane with Low-E 8 0.250 2
Wall 7: Wood Frame, 16" o.c.621 21.0 0.0 0.057 25
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 1 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Window 13: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5
Window 14: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5
Window 15: Vinyl/Fiberglass Frame:Double Pane with Low-E 21 0.250 5
Door 1: Solid 41 0.170 7
Door 2: Solid 41 0.170 7
Door 3: Solid 41 0.170 7
Wall 8: Wood Frame, 16" o.c.216 21.0 0.0 0.057 12
Wall 9: Wood Frame, 16" o.c.328 21.0 0.0 0.057 18
Window 16: Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.250 2
Window 17: Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.250 2
Crawl 1: Solid Concrete or Masonry
Wall height: 3.0'
Depth below grade: 2.6'
Insulation depth: 3.0'
621 19.0 0.0 0.054 27
Crawl 2: Solid Concrete or Masonry
Wall height: 3.0'
Depth below grade: 2.6'
Insulation depth: 3.0'
217 19.0 0.0 0.054 9
Crawl 3: Solid Concrete or Masonry
Wall height: 3.0'
Depth below grade: 2.6'
Insulation depth: 3.0'
216 19.0 0.0 0.054 9
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 2 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Inspection Checklist
Requirements: 41.0% were addressed directly in the REScheck software
REScheck Software Version 4.6.2
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Pre-Inspection/Plan Review Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
103.1,
103.2
[PR1]1
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
103.1,
103.2,
403.7
[PR3]1
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
Complies
Does Not
Not Observable
Not Applicable
302.1,
403.7
[PR2]2
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 3 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Section
#
& Req.ID
Foundation Inspection Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
402.2.11
[FO7]1
Unvented crawl space wall
insulation R-value.
R-_____
R-_____
R-_____
R-_____
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[FO8]1
Unvented crawl space wall
insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.2.11
[FO9]1
Unvented crawl space continuous
vapor retarder installed over
exposed earth, joints overlapped
by 6 in. and sealed, extending at
least 6 in. up and attached to the
wall.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.2.11
[FO10]1
Unvented crawl space wall
insulation depth of burial or
distance from top of wall.
_____ in._____ in.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2.1
[FO11]2
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.9
[FO12]2
Snow- and ice-melting system
controls installed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 4 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Section
#
& Req.ID
Framing / Rough-In Inspection Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
402.1.1,
402.3.4
[FR1]1
Door U-factor.U-_____U-_____Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1,
402.3.1,
402.3.3,
402.3.6,
402.5
[FR2]1
Glazing U-factor (area-weighted
average).
U-_____U-_____Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.3
[FR4]1
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.4.1.1
[FR23]1
Air barrier and thermal barrier
installed per manufacturer’s
instructions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.4.3
[FR20]1
Fenestration that is not site built
is listed and labeled as meeting
AAMA /WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.4.5
[FR16]2
IC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate ≤2.0 cfm
leakage at 75 Pa.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.2.1
[FR12]1
Supply and return ducts in attics
insulated >= R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
Complies
Does Not
Not Observable
Not Applicable
403.3.3.5
[FR15]3
Building cavities are not used as
ducts or plenums.
Complies
Does Not
Not Observable
Not Applicable
403.4
[FR17]2
HVAC piping conveying fluids
above 105 ºF or chilled fluids
below 55 ºF are insulated to ≥R-
3.
R-_____R-_____Complies
Does Not
Not Observable
Not Applicable
403.4.1
[FR24]1
Protection of insulation on HVAC
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.3
[FR18]2
Hot water pipes are insulated to
≥R-3.
R-_____R-_____Complies
Does Not
Not Observable
Not Applicable
403.6
[FR19]2
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 5 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 6 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Section
#
& Req.ID
Insulation Inspection Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
303.1
[IN13]2
All installed insulation is labeled
or the installed R-values
provided.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.1.1,
402.2.5,
402.2.6
[IN3]1
Wall insulation R-value. If this is a
mass wall with at least ½ of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R-_____
Wood
Mass
Steel
R-_____
Wood
Mass
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[IN4]1
Wall insulation is installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 7 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
402.1.1,
402.2.1,
402.2.2,
402.2.6
[FI1]1
Ceiling insulation R-value.R-_____
Wood
Steel
R-_____
Wood
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.1.1,
303.2
[FI2]1
Ceiling insulation installed per
manufacturer’s instructions.
Blown insulation marked every
300 ft².
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.2.3
[FI22]2
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.2.4
[FI3]1
Attic access hatch and door
insulation ≥R-value of the
adjacent assembly.
R-_____R-_____Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.4.1.2
[FI17]1
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
ACH 50 =_____ACH 50 =_____Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.2.3
[FI4]1
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
occur during Framing Inspection.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2
[FI27]1
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer’s air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer’s air
handler enclosure.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2.1
[FI24]1
Air handler leakage designated
by manufacturer at <=2% of
design air flow.
Complies
Does Not
Not Observable
Not Applicable
403.1.1
[FI9]2
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
Complies
Does Not
Not Observable
Not Applicable
403.1.2
[FI10]2
Heat pump thermostat installed
on heat pumps.
Complies
Does Not
Not Observable
Not Applicable
403.5.1
[FI11]2
Circulating service hot water
systems have automatic or
accessible manual controls.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 8 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
403.6.1
[FI25]2
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits.
Complies
Does Not
Not Observable
Not Applicable
403.2
[FI26]2
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperature.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.1
[FI28]2
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.2
[FI29]2
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.2
[FI30]2
Water distribution systems that
have recirculation pumps that
pump water from a heated water
supply pipe back to the heated
water source through a cold
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104ºF.
Complies
Does Not
Not Observable
Not Applicable
403.5.4
[FI31]2
Drain water heat recovery units
tested in accordance with CSA
B55.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
Complies
Does Not
Not Observable
Not Applicable
404.1
[FI6]1
75% of lamps in permanent
fixtures or 75% of permanent
fixtures have high efficacy lamps.
Does not apply to low-voltage
lighting.
Complies
Does Not
Not Observable
Not Applicable
404.1.1
[FI23]3
Fuel gas lighting systems have
no continuous pilot light.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 9 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
401.3
[FI7]2
Compliance certificate posted.Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
303.3
[FI18]3
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title: 175 Curry Dr
Data filename: C:\Users\Michele\Documents\REScheck\175 Curry.rck Page 10 of 10
04/21/21Report date:
Reviewed by
SAFEbuilt
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
21.00Above-Grade Wall
19.00Below-Grade Wall
0.00Floor
49.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.25Window
0.17Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name:Date:
Comments
Reviewed by
SAFEbuilt