HomeMy WebLinkAboutPLANS Remodel 650 Findley Ct 2022-07-20PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PLANS AND CONSTRUCTION SHALL MEET COMPLIANCE WITH THE 2015 IRC AND ALL APPLICABLE MUNICIPAL CODES & ORDINANCES KEEP ALL PERMIT DOCUMENTS TOGETHER & ON-SITE FOR INSPECTORS REVIEW This structure must comply with the requirements of the 2020 National Electrical Code APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 07/20/2022 PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND Cement based substrate or equal on shower/tub walls - Typ Glazing installed in hazardous locations as defined in Section R308.4 shall be Tempered Glass Freeze Protect pipes per P2603.5 Provide 50 cfm fan in bathroom - vented to exterior - when no natural ventilation is provided by window Provide Anti-Scald valves on shower or tub/shower combination valves Showers shall be finished 72 inches above the floor with a non-absorbent material. Shower door minimum clear opening width is 24 inches and open outward Toilets & Lavatories shall be provided with a min. of 21 inches in front each fixture - each side of Toilets shall have 15 inches from the center line of the toilet and any sidewall or other obstructions. Fire Block shall be provided in enclosed wood framed walls per locations designated in R302.11 Access doors from Conditioned spaces to unconditioned spaces (E.G. Attics and Crawlspaces) shall be weatherstripped and insulated. FP - Fireplace Installation & Clearances per Manufacturers Installation Instructions/Specifications - Manual shall be on site for Inspectors Review - Any New Gas piping shall be tested for not less than 15 min. @ 1 1/2 times the proposed maximum working pressure but not less than 10 psig. - before it is put into service. See section G2417.4.1 and local amendments Crawlspace access of min. of 16"x24" M1507.2 - Exhaust Air from bathrooms & toilet rooms shall not be recirculated within the residence or other dwelling units and be exhausted directly outside PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND Cement based substrate or equal on shower/tub walls - Typ Glazing installed in hazardous locations as defined in Section R308.4 shall be Tempered Glass Freeze Protect pipes per P2603.5 Provide 50 cfm fan in bathroom - vented to exterior - when no natural ventilation is provided by window Provide Anti-Scald valves on shower or tub/shower combination valves Showers shall be finished 72 inches above the floor with a non-absorbent material. Shower door minimum clear opening width is 24 inches and open outward Toilets & Lavatories shall be provided with a min. of 21 inches in front each fixture - each side of Toilets shall have 15 inches from the center line of the toilet and any sidewall or other obstructions. M1507.2 - Exhaust Air from bathrooms & toilet rooms shall not be recirculated within the residence or other dwelling units and be exhausted directly outside FP - Fireplace Installation & Clearances per Manufacturers Installation Instructions/Specifications - Manual shall be on site for Inspectors Review - Any New Gas piping shall be tested for not less than 15 min. @ 1 1/2 times the proposed maximum working pressure but not less than 10 psig. - before it is put into service. See section G2417.4.1 and local amendments Fire Block shall be provided in enclosed wood framed walls per locations designated in R302.11 Access doors from Conditioned spaces to unconditioned spaces (E.G. Attics and Crawlspaces) shall be weatherstripped and insulated. Air gap required at or within dishwasher - per P2717.1 Appliance and all Equipment Vent Terminations shall be per manufacturers specifications Provide attic access of min. of 22"x30" to enclosed attic space of combustible roof construction with a vertical height of 30" If kitchen hood greater than 400 cfm, must have approx equal make up air on automatically controlled damper - Per M1503.4 WATER HAMMER ARRESTORS ARE TO BE USED ON ALL APPLIANCES WITH QUIICK CLOSING VALVES. Provide Window Fall Protection per R312.2 Do not remove Manufacturers stickers on new windows until after all final inspections PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. NOTIFY E.O.R. OF ANY DISCREPANCIES MAIN FLOOR FRAMING PLAN 1/4" = 1'-0" (E) 11 7/8" I-JOISTS TO REMAIN (E) WALKOUT BASEMENT N (E) 11 7/8" I-JOISTS TO REMAIN (E) BEAM, TO REMAIN(E) BEAM, TO REMAIN (E) COLUMN TO REMAIN, TYP. PLAN NOTES: (N) DENOTES NEW FRAMING/STRUCTURE (E) DENOTES EXISTING FRAMING/STRUCTURE (F.V.) DENOTES FIELD VERIFY EXISTING DIMENSION / STRUCTURE EXISTING EXTERIOR WALL STUDS: 2x6's @ 16" O.C. (F.V.) ALL EXISTING HEADERS TO REMAIN UNLESS NOTED OTHERWISE (E) POST TO REMAIN (N) (2) 2x8 HDR w/ (1) 2x6 (T) & (1) 2x6 (K) EACH END (E ) D E C K J O I S T S , TO R E M A I N STRUCTURAL GENERAL NOTES AND SPECIFICATIONS: PROJECT: REMODEL AT 650 FINDLEY COURT, ESTES PARK, COLORADO CODE: THE 2015 INTERNATIONAL RESIDENTIAL CODE. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THIS CODE. RISK CATEGORY: II STRUCTURE DESIGN LOADS: ROOF DEAD LOAD = 20 PSF ROOF LIVE LOAD = 20 PSF GROUND SNOW LOAD = 67 PSF (@ 7700' ELEVATION); ROOF SNOW LOAD = 52 PSF (MINIMUM); [Ce=Is = 1.0; Ct = 1.1] FLOOR DEAD LOAD = 12 PSF FLOOR LIVE LOAD = 40 PSF DECK LIVE LOAD = 67 PSF (GROUND SNOW) WIND SPEED = 175 MPH (ULTIMATE), EXPOSURE C SEISMIC DESIGN CATEGORY B MINIMUM FROST DEPTH = 30 INCHES MATERIALS: WOOD FRAMING: DIMENSIONAL LUMBER SHALL BE VISUALLY GRADED HEM-FIR #2 OR BETTER, UNLESS NOTED OTHERWISE. FB=850 PSI; FV=150 PSI; E=1300 KSI. TIMBER BEAMS & POSTS SHALL BE VISUALLY GRADED DOUGLAS FIR-LARCH #2 OR BETTER, U.N.O. LAMINATED VENEER LUMBER (LVL) SHALL BE GRADED TO THE FOLLOWING MINIMUM ALLOWABLES: FB=2600 PSI; FV=285 PSI; E=1900 KSI. LAMINATED STRAND LUMBER (1.55E LSL BEAMS) SHALL BE GRADED TO THE FOLLOWING MINIMUM ALLOWABLES: FB=2325 PSI; FV=310 PSI; E=1550 KSI. LAMINATED STRAND LUMBER (1.3E LSL STUDS) SHALL BE GRADED TO THE FOLLOWING MINIMUM ALLOWABLES: FB=1700 PSI; FV=425 PSI; E=1300 KSI. GLUE LAMINATED TIMBER (GLULAM OR G.L.): SIMPLE SPAN=24F-V4; CONTINUOUS SPAN=24F-V8 w/ FB=2400 PSI; FV=240 PSI; E=1800 KSI. FLOOR SHEATHING SHALL BE 23/32" APA RATED STURD-I-FLOOR WITH A 24 SPAN RATING. GLUE AND ATTACH AS NOTED ON PLANS. ROOF SHEATHING SHALL BE 15/32" SHEATHING WITH AN APA SPAN RATING OF 32/16 ATTACHED AS NOTED ON PLANS. WALL SHEATHING SHALL BE 7/16" APA RATED SHEATHING ATTACHED AS NOTED ON PLANS. ROOF, WALL & FLOOR SHEATHING SHALL BE APA TRADEMARKED EXPOSURE 1 WHEN EXPOSED ONLY DURING CONSTRUCTION AND SHALL CONFORM TO THE AMERICAN PLYWOOD ASSOCIATION STANDARD. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE BUILDING CODE UNLESS OTHERWISE NOTED. ALL METAL FRAMING CONNECTORS SHALL BE SIMPSON STRONG-TIE OR APPROVED EQUAL INSTALLED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. ALL WOOD IN CONTACT WITH CONCRETE OR EXPOSED TO WEATHER SHALL BE PRESERVATIVE TREATED (P.T.) IN ACCORDANCE WITH IRC SECTION R317. ALL PRESERVATIVE TREATED LUMBER SHALL CONFORM TO AWPA STANDARD U1 AND THE APPROPRIATE USE CATEGORY. CONNECTORS USED IN CONTACT WITH P.T. WOOD SHALL BE COATED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. FASTENERS USED IN P.T. WOOD SHALL CONFORM WITH IRC SECTION R317.3.1. NOTES: THE STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, PLUMBING AND SITE DRAWINGS. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS SHOWN ON THIS PLAN PRIOR TO CONCRETE PLACEMENT. CONFLICTS IN DIMENSION, INTERFERENCE OR OMISSIONS DISCOVERED IN THE COURSE OF WORK SHALL BE DIRECTED TO THE ARCHITECT PRIOR TO CONTINUATION OF CONSTRUCTION. THE EXISTING CONDITIONS DEPICTED ON THESE PLANS ARE BASED ON THE BEST AVAILABLE INFORMATION AND SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. THE STRUCTURAL DRAWINGS REPRESENT THE FINAL STRUCTURE. THE DRAWINGS DO NOT INDICATE THE CONTRACTORS MEANS, METHODS, TECHNIQUES, SEQUENCES OF CONSTRUCTION AND JOB SAFETY. THE ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO FOLLOW PLANS, SPECIFICATIONS, AND/OR ENGINEERING RECOMMENDATIONS, NOR IS THE ENGINEER OF RECORD RESPONSIBLE FOR ECONOMIC LOSS AND/OR DELAYS ON THE CONTRACTOR OR SUBCONTRACTORS. ALL CONSTRUCTION SHALL BE ADEQUATELY BRACED TO PREVENT DISTORTION AND DAMAGE DUE TO CONSTRUCTION LOADS AND NATURAL FORCES. THE CONTRACTOR SHALL MAKE ALLOWANCES FOR DIFFERENCE BETWEEN TEMPERATURE DURING ERECTION AND MEAN TEMPERATURE WHEN STRUCTURE IS COMPLETED AND IN SERVICE. ( 9 7 0 ) 6 6 3 - 0 5 4 8 C o l o r a d o L o v e l a n d sheet c 2 0 2 2 K e n n e y L e e a r c h i t e c t u r e g r o u p i n c . Ke n n e y L e e ar c h i t e c t u r e g r o u p , i n c . ES T E S P A R K BR I T T A N R e s i d e n c e RE M O D E L F O R : 65 0 F I N D L E Y C O U R T CO L O R A D O S1.1 970-420-5316 mcbridestructural.com john@mcbridestructural.com PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND (E) HEADER, TO REMAIN VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION. NOTIFY E.O.R. OF ANY DISCREPANCIES ROOF FRAMING PLAN 1/4" = 1'-0"N PLAN NOTES: (N) DENOTES NEW FRAMING/STRUCTURE (E) DENOTES EXISTING FRAMING/STRUCTURE (F.V.) DENOTES FIELD VERIFY EXISTING DIMENSION / STRUCTURE EXISTING EXTERIOR WALL STUDS: 2x6's @ 16" O.C. (F.V.) ALL EXISTING HEADERS TO REMAIN UNLESS NOTED OTHERWISE HEADER SCHEDULE MARK HEADER TRIMMER STUDS (T) KING STUDS (K) H1 (2) 2x6 (1) 2x6 (2) 2x6 H2 (2) 2x8 (1) 2x6 (2) 2x6 -ABOVE SCHEDULE APPLIES TO ALL HEADERS ON THIS PLAN, UNLESS NOTED OTHERWISE ON THE PLAN. -REFER TO GENERAL NOTES FOR GRADES & SPECIES OF WOOD. -VERIFY LOCATIONS OF HEADERS WITH ARCHITECTURAL PLANS. -TRIMMER (T) AND KING (K) STUDS ARE THE NUMBER OF EACH TYPE OF STUD ON EACH END OF THE HEADER. (E) P.E. TRUSSES, TO REMAIN (N) 3-PLY 1 3/4" x 11 1/4" LVL HDR w/ (2) 2x6 (T) & (3) 2x6 (K) EACH END(N) H2 (N) H1 (N) H1 (1) 2x6 (T) (2) 2x6 (K) (1) 2x6 (T) (N) H1 (E ) P . E . T R U S S E S , TO R E M A I N (E) BEARING WALL ( 9 7 0 ) 6 6 3 - 0 5 4 8 C o l o r a d o L o v e l a n d sheet c 2 0 2 2 K e n n e y L e e a r c h i t e c t u r e g r o u p i n c . Ke n n e y L e e ar c h i t e c t u r e g r o u p , i n c . ES T E S P A R K BR I T T A N R e s i d e n c e RE M O D E L F O R : 65 0 F I N D L E Y C O U R T CO L O R A D O S2.1 970-420-5316 mcbridestructural.com john@mcbridestructural.com PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND SD/CO A minimum of 75% of the lamps in permanently installed lighting fixtures shall be high efficacy lamps. per 2018 N1104.1 The entire building must be provided with Smoke Detectors one in each sleeping room, outside each sleeping room and on each additional story of the dwelling CO Detectors are Required outside of bedrooms and within 15' of bedroom doors. Bathrooms - Min one - 20 amp circuit - bathroom countertops or similar work surfaces shall be GFCI protected - Typical for each bathroom (2020 NEC 210.8) See 410.10 (D) for new requirements for where and what type of fixtures can be installed in areas containing bathtubs/showers Outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas and similar rooms or areas shall be AFCI protected - per E3902.16 Per 2020 NEC 210.8 - All basement receptacles (finished or not) except for permanently installed fire or burglar alarms shall be GFCI Protected. PERMIT #22-EP-00377 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND SD/CO A minimum of 75% of the lamps in permanently installed lighting fixtures shall be high efficacy lamps. per 2018 N1104.1 The entire building must be provided with Smoke Detectors one in each sleeping room, outside each sleeping room and on each additional story of the dwelling CO Detectors are Required outside of bedrooms and within 15' of bedroom doors. See 410.10 (D) for new requirements for where and what type of fixtures can be installed in areas containing bathtubs/showers Outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas and similar rooms or areas shall be AFCI protected - per E3902.16 210.52(C)(1).(C)(2).(C)(3) Has been changed to Use the square footage of islands and Peninsulas for how many outlets are required. Replacement of existing receptacles outlets shall comply with NEC 406.4 D 1-6