HomeMy WebLinkAboutPLANS Remodel 415 Parkview Ln 2022-07-22N Bill Riley 415 Park View Lane Estes Park, CO 80517 186' 157' 206' 97' 8 5 ' 155' 1 0 8 '108' 281' 20' Existing Garage Existing House Proposed 20' x 14' Addition 50' 80'150' PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND Matched to Soils Report PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND All work shall be performed by Licensed Contractors OR work shall be performed by the homeowner residing in the dwelling. Issuance of a permit or approval of these construction documents shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the adopted codes or of other ordinances of this jurisdiction. A permit presuming to give authority to violate or cancel the provisions of these codes shall be invalid. R105.4 PLANS AND CONSTRUCTION SHALL MEET THE 2018 IRC AND ALL APPLICABLE MUNICIPAL CODES & ORDINANCES ALL PERMIT DOCUMENTS: ARCHITECTURAL PLANS, ENGINEERED PLANS, SOILS REPORTS, TRUSS DRAWINGS, ENERGY CODE REPORTS/RESCHECKS, ETC... MUST BE KEPT TOGETHER & ONSITE FOR INSPECTORS REVIEW. DO NOT COVER WORK UNTIL IT HAS BEEN APPROVED BY INSPECTION - IF YOU HAVE FAILED A ROUGH INSPECTION YOU MUST HAVE AN APPROVED REINSPECTION BEFORE YOU COVER THE WORK UP. This structure must comply with the requirements of the 2020 National Electrical Code Fire Block shall be provided in enclosed wood framed walls per R302.11 Access doors from Conditioned spaces to unconditioned spaces (E.G. Attics and Crawlspaces) shall be weatherstripped and insulated. Provide attic access of min. of 22"x30" to enclosed attic space of combustible roof construction with a vertical height of 30" APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 07/22/2022 PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND STAMPED ENGINEERED TRUSS DRAWINGS SHALL BE ON-SITE FOR INSPECTOR TO REVIEW OK REFER TO ENGINEERS LETTER FOR STRUCTURAL DETAILS PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND R-49 CEILING INSULATION OK FOLLOW MANUFACTURER'S INSTRUCTIONS: Manufacturer's installation instructions, as required by code, shall be available on the job site at the time of inspection. R106.1.2 STAMPED ENGINEERED TRUSS DRAWINGS SHALL BE ON-SITE FOR INSPECTOR TO REVIEW Seal all longitudinal joints on all ducts, supply, return, vent, and exhaust. CONDITION CRAWLSPACE - ADD INSULATION & VAPOR RETARDER ON GROUND PER SECTION R408 Provide Air Barriers/insulation for all components as listed per Table N1102.4.1.1 & 2012 ICC 400 Standard for Lot Structures R-20 2015 PRESCRIPTIVE INSULATION VALUES: CRAWLSPACE = R-15/19 WALLS = R-20 or R-13+R-5 continuous ATTIC/CEILING = R-49 FENESTRATION U-FACTOR VALUE: WINDOWS = 0.32 Prescriptive path must follow Section N1101 through N1104 of Chapter 11 of the 2015 IRC PERMIT #22-EP-00373 Field Copy Print out legibly & in color and have on site for inspector REVIEWED BY SAFEBUILT - PBLAND