HomeMy WebLinkAboutPLANS Remodel 321 Big Horn Dr Unit C3 2022-07-11PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
07/11/2022
This structure must comply
with the requirements of the
2020 National Electrical
Code
REFER TO ENGINEERS PLANS FOR
ALL STRUCTURAL DETAILS
Glazing installed in hazardous locations as defined
in Section R308.4 shall be Tempered Glass
Fall Protection is required where applicable (R312)
- Windows that are operable at 6' above grade with
sill height lower than 24"
Fire Block shall be provided in enclosed wood
framed walls per locations designated in R302.11
Per R311.6 - Hallways shall be not less
than 3 feet.
Follow Manufacturer's installation instructions:
Manufacturer's installation instructions, as required by
code, shall be available on the job site at the time of
inspection. R106.1.2
IC Rated Sealed Recess Cans in Attic
Receptacles cannot be installed within a zone of 3' horizontally & 8'
from the bathtub rim or shower stall threshold (410.10D - 2020 NEC)
Provide Tamper-resistant receptacles - Installed Per E4002.14
Outlets installed in kitchens, family rooms, dining rooms, living rooms,
parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets,
hallways, laundry areas and similar rooms or areas shall be AFCI
protected - per E3902.16
See 410.10 (D) for new requirements for where and what type of
fixtures can be installed in areas containing bathtubs/showers
A minimum of 75% of the lamps in permanently installed lighting
fixtures shall be high efficacy lamps. per 2018 N1104.1
Bathrooms - Min one - 20 amp circuit - bathroom countertops or
similar work surfaces shall be GFCI protected - Typical for each
bathroom (2020 NEC 210.8)
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
This structure must comply
with the requirements of the
2020 National Electrical
Code
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
07/11/2022
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
ESTES PARK - ICE BARRIER
REQUIREMENTS:
An ice barrier, such as a self-adhering polymer
modified bitumen sheet, shall be installed on the
entire area of roof slopes from two units vertical
in 12 units horizontal (17-percent slope), up to
four units vertical in 12 units horizontal
(33-percent slope).
EAVE BAFFLE TO EXTEND PAST INSULATION.
ROOF VENTS REQUIRED FOR ENCLOSED
RAFTER SPACES PER R806 & MANUFACTURERS
SPECIFICATIONS
FLASHING SHALL BE INSTALLED IN A MANNER THAT
WILL PREVENT MOISTURE ENTERING WALLS AND
ROOFS R903.2
PROVIDE TO INSPECTOR ACTUAL ROOF VENTING
CALCULATION TO VERIFY COMPLIANCE WHEN
REQUESTED AT INSPECTION
Shingles shall meet designed wind load of 175 psf & local
amendment requirements
- All shingles shall also be installed per manufacturers
installation instructions(R904.1)
DRIP EDGE IS REQUIRED ON ALL RAKES AND EAVES
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
This structure must comply
with the requirements of the
2020 National Electrical
Code
Cement based substrate or equal on shower/tub walls
Freeze Protect pipes per P2603.5
Provide Anti-Scald valves on shower or tub/shower
combination valves
Toilets & Lavatories shall be provided with a min.
of 21 inches in front each fixture
- each side of Toilets shall have 15 inches from the
center line of the toilet and any sidewall or other
obstructions.
Provide 50 cfm fan in bathroom - vented to exterior -
when no natural ventilation is provided by window
Showers shall be finished 72 inches above the floor
with a non-absorbent material. Shower door minimum
clear opening width is 24 inches and open outward
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
PERMIT #22-EP-00361
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND