HomeMy WebLinkAboutPLANS Deck 1861 Raven Ave Unit G3 2022-06-17PERMIT #22-EP-00324
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
Plastic composite decking, treads and handrail to
comply with R507.2.2 & ASTM D7032.
Verify composite decking can span the required
joist spacing
Min. Guardrail Requirements (R312):
Guardrail required for over 30"
Guardrail openings = less than 4"
Guardrail to meet 200lb. uniform live load
APPROVED by SAFEbuilt;
2018 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
06/17/2022
Plastic composite decking, treads and handrail to
comply with R507.2.2 & ASTM D7032.
Verify composite decking can span the required
joist spacing
Min. Guardrail Requirements (R312):
Guardrail required for over 30"
Guardrail openings = less than 4"
Guardrail to meet 200lb. uniform live load
PERMIT #22-EP-00324
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY SAFEBUILT - PBLAND
APPROVED by SAFEbuilt;
2018 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
06/17/2022