HomeMy WebLinkAboutPLANS Solar 522 Driftwood Ave 2021-01-2001/20/2021 EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 VICINITY MAP AERIAL MAP PV-1 REV #1: REV #2: REV #3: GOVERNING CODES: ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: ·2020 NATIONAL ELECTRIC CODE (NEC) ·2015 INTERNATIONAL FIRE CODE ·2015 INTERNATIONAL BUILDING CODE (IBC) ·2015 INTERNATIONAL EXISTING BUILD CODE (IEBC) ·2015 INTERNATIONAL RESIDENTIAL CODE (IRC) ·2015 INTERNATIONAL MECHANICAL CODE ·2015 INTERNATIONAL FUEL GAS CODE ·2015 INTERNATIONAL PLUMBING CODE ·2015 INTERNATIONAL ENERGY CONSERV. CODE ·OSHA 29 CFR 1910.269 ·UNDERWRITERS LABORATORIES (UL) STANDARDS GENERAL 1.UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PHOTOVOLTAIC SYSTEM. 2.110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION 3.CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. 4.CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 5.ALL EQUIPMENT AND ASSOCIATED CONNECTIONS, ETC, AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL. 6.THE CONTRACTOR OR OWNER MUST PROVIDE ROOF ACCESS (LADDER TO ROOF) FOR ALL THE REQUIRED INSPECTIONS. LADDERS MUST BE OSHA APPROVED, MINIMUM TYPE I WITH A 250LB. RATING, IN GOOD CONDITION AND DESIGNED FOR ITS INTENDED USE. 7.CONTRACTOR SHALL VERIFY THAT THE ROOF STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. 8.LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT EXCEED MANUFACTURER RECOMMENDATIONS FOR FASTENERS INTO ENGINEERED STRUCTURAL MEMBERS. 9.AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. 10.WHERE DC CONDUCTORS ARE RUN INSIDE BUILDING, THEY SHALL BE CONTAINED IN A METAL RACEWAY; THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT. 11. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES- - NO BUILDING, PLUMBING OR MECHANICAL VENTS TO BE COVERED, CONSTRUCTED OR ROUTED AROUND SOLAR MODULES. 12. ALL FIELD -INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS. ELECTRICAL 1.WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25°C AND MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET RATED AT 90°C. 2.EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE 2 OR PV-TYPE WIRE. 3.PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR-CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. 4.ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. 5.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 6.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 7.REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 8.FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. 9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/GEC PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER GEC VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT LISTED LUG. 12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. 14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AS BUS BARS WITHIN LISTED EQUIPMENT. 15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD". 16. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. 17. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED. PV-1 - COVER PAGE PV-2 - PROPERTY PLAN PV-3 - SITE PLAN PV-3.1 - ATTACHMENT (UNIRAC) PV-4 - 1-LINE DIAGRAM PV-5 - ELECTRICAL CALCULATIONS PV-6 - ELECTRICAL PHOTOS PV-7 - OPTIMIZER MAP SHEET INDEX: ROJAS RESIDENCE PHOTOVOLTAIC SYSTEM 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 SYSTEM SIZE: 13.14 kW-DC | 11.40 kW-AC MODULE: ( 36 ) SOLARIA POWERXT-365R-AC INVERTER: ( 1 ) SOLAREDGE SE11400H-US ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH COVER PAGE PARCEL MAP N EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 SCALE: 1/8" = 1'-0" LEGEND: PROPERTY LINE: ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH PROPERTY PLAN PV-2 DRIVEWAY: 5 2 2 D R I F T W O O D A V E DRIVEWAY PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E 14'-3" 6' - 6 " 3' - 9 " 13'-7" SINGLE FAMILY HOME 01/20/2021 N EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 LEGEND UM MP AC MAIN SERVICE METER AND SERVICE POINT MAIN SERVICE PANEL UTILITY AC DISCONNECT SCALE: 3/16" = 1'-0" CONDUIT TO BE RUN ON CONDUIT BLOCKS MIN. 1" ABOVE ROOF SURFACE, CLOSE TO RIDGE LINES, AND UNDER EAVES; TO BE PAINTED TO MATCH EXTERIOR/EXISTING BACKGROUND COLOR OF ITS LOCATION; TO BE LABELED AT MAX 10' INTERVALS. CONDUIT RUNS ARE APPROXIMATE AND ARE TO BE DETERMINED IN THE BY THE INSTALLERS CONDUIT RUN ELEVATION DETAIL FIRE CODE SETBACK MODULE INFORMATION MODULE TYPE SOLARIA POWERXT 365R-PD MAX DESIGN LOAD (WIND & SNOW)2400 PA UPWARD / 5400 PA DOWNWARD MODULE WEIGHT 46 LBS/MODULE MODULE DIMENSIONS (H X L X D)64" X 48" X 1.6" MODULE AREA 19.55 FT2 PHOTOVOLTAIC SYSTEM: DC SYSTEM SIZE: 13.14 kW AC SYSTEM SIZE: 11.40 kW I ( 1 ) SOLAREDGE SE11400H-US INVERTER WITH INTEGRATED DC DISCONNECT ( 36 ) SOLARIA POWERXT-365R-AC WITH SOLAREDGE P370 OPTIMIZERS MOUNTED UNDER EACH MODULE. MODULE MECHANICAL SPECIFICATIONS DESIGN WIND SPEED 140 MPH DESIGN SNOW LOAD 45 PSF # OF STORIES 1 ROOF PITCH 25 ° TOTAL ARRAY AREA (SQ. FT)703.80 TOTAL ROOF AREA (SQ. FT) 1324 ARRAY SQ. FT / TOTAL ROOF SQ. FT 53.16 ROOF SECTION 1: 22 MODULES AZIMUTH: 180 ° PITCH: 25 ° ROOF TYPE: ASPHALT SHINGLE ROOF SECTION 2: 14 MODULES AZIMUTH: 0 ° PITCH: 25 ° ROOF DETAIL STRING DETAIL SOLAREDGE STRINGS STRING DETAIL SOLAREDGE STRINGS STRING DETAIL SOLAREDGE STRINGS STRING DETAIL SOLAREDGE STRINGS STRING # 1: 12 MODULES STRING # 2: 10 MODULES STRING # 3: 14 MODULES STRING DETAIL SOLAREDGE STRINGS 1 2 ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH SITE PLAN PV-3 JUNCTION BOX AND CONDUIT I MP AC UM 1 2 3' - 0 " 3'-0" (TYP.) 01/20/2021 EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH UNIRAC DETAILS PV-3.1 01/20/2021 EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 PHOTOVOLTAIC SYSTEM: DC SYSTEM SIZE: 13.140 kW AC SYSTEM SIZE: 11.400 kW INVERTER: ( 1 ) SOLAREDGE SE11400H-US MODULE: ( 36 ) SOLARIA POWERXT-365R-AC NOTES: ·MODULES ARE BONDED TO RAIL USING UL 2703 RATED BONDING SYSTEM - INTEGRATED BONDING MID-CLAMPS + DIRECT-BURIAL LAY-IN-LUGS; SEE ATTACHED FOR SPECIFICATIONS ·IF APPLICABLE: ·PV DC SYSTEM IS UNGROUNDED ·PV ARRAY WILL HAVE A GROUNDING ELECTRODE SYSTEM IN COMPLIANCE WITH NEC 250.58 AND 690.47(A) ·PV SOURCE, OUTPUT, AND INVERTER INPUT CIRCUIT WIRING METHODS SHALL COMPLY WITH NEC 690.1(G) ·BACKFED PV BREAKER WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, PAGE ·BARE COPPER IS TRANSITIONED TO THWN-2 VIA IRREVERSIBLE CRIMP; WHEN PRESENT, THE GEC TO BE CONTINUOUS ·INVERTER(S) TO BE COMPLIANT WITH UL 1741 SUPPLEMENT A ·CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS VISIBLE LOCKABLE LABELED DISCONNECT IS WITHIN 10' OF THE UTILITY METER PV MODULE ELECTRICAL SPECIFICATIONS MODULE TYPE SOLARIA 365W POWER-XT POWER MAX (PMAX)365W OPEN CIRCUIT VOLTAGE (VOC)48V SHORT CIRCUIT CURRENT (ISC)9.58A MAX POWER-POINT VOLTAGE (VMP)39.9V MAX POWER-POINT CURRENT (IMP)9.16A SERIES FUSE RATING 15A INVERTER ELECTRICAL SPECIFICATIONS INVERTER TYPE SOLAREDGE SE11400H-US MAX INPUT DC VOLTAGE 480V MAX INPUT CURRENT 30.5A NOMINAL DC INPUT VOLTAGE 400V MAXIMUM OUTPUT POWER 11400W MAXIMUM CONT. OUTPUT CURRENT 47.5A CEC EFFICIENCY 99% POWER OPTIMIZER ELECTRICAL SPECIFICATIONS OPTIMIZER TYPE SOLAREDGE P370 RATED INPUT DC POWER 370W MAXIMUM INPUT VOLTAGE (VOC)60V MAXIMUM SHORT CIRCUIT CURRENT (ISC)11A MAXIMUM DC INPUT CURRENT 13.75A MAXIMUM OUTPUT CURRENT 15A MAXIMUM OUTPUT VOLTAGE 60V MINIMUM STRING LENGTH 8 MAXIMUM POWER PER STRING 5700W (6000W WITH SE7600- SE11400) CONDUCTOR AND CONDUIT SCHEDULE TAG WIRE TYPE WIRE SIZE # OF CONDUCTORS CONDUIT TYPE MIN. CONDUIT SIZE 1 PV WIRE #10 2 - L1 L2 FREE AIR N/A 1 BARE COPPER #6 1 - BARE FREE AIR N/A 2 THWN-2 #10 2 - L1 L2 EMT 3/4" 2 THWN-2 EGC #10 1 - GND EMT 3/4" 3 THWN-2 #6 3 - L1 L2 N EMT 3/4" 3 THWN-2 EGC #8 1 - GND EMT 3/4" (N) AC DISCONNECT 60A 240V NEMA 3R FUSIBLE, VISIBLE LOCKABLE LABELED WITH 60A FUSES P370 DC OPTIMIZERS 14 SOLARIA POWERXT-365R-AC IN STRING #3 10 SOLARIA POWERXT-365R-AC IN STRING #2 12 SOLARIA POWERXT-365R-AC IN STRING #1 OVER-CURRENT PROTECTION DEVICE (OCPD) CALCULATIONS INVERTER TYPE SOLAREDGE 11400H-US # OF INVERTERS 1 MAX CONTINUOUS OUTPUT CURRENT 47.5A (# OF INVERTERS) X (MAX CONT. OUTPUT CURRENT) X 125% <= OCPD RATING ( 1 x 47.5A x 1.25)= 59.38A <= 60 A, OK ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH 1-LINE DIAGRAM & CALCULATIONS PV-4 EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 ! WARNING ! DUAL POWER SOURCES. SECOND SOURCE IS PV SYSTEM LABEL 7 PHOTOVOLTAIC AC DISCONNECT OPERATING CURRENT: 60A AC OPERATING VOLTAGE: 240 V AC LABEL 5 AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.54] ! WARNING ! ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LABEL 3 AT EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.13 AND 690.15] PHOTOVOLTAIC DC DISCONNECT PHOTOVOLTAIC AC DISCONNECT LABEL 10 AT EACH DC DISCONNECTING MEANS [NEC 690.13(B)] WARNING: PHOTOVOLTAIC POWER SOURCE LABEL 12 AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(G)] LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] LABEL 13 AT EACH AC DISCONNECTING MEANS [NEC 690.13(B)] ! CAUTION ! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING ! POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVISE LABEL 14 AT POINT OF INTERCONNECTION OVERCURRENT DEVICE [NEC 705.12(B)(2)(3)(B)] INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED LABEL 9 AT UTILITY METER [NEC 690.56(B)] LABEL 4 AT EACH DC DISCONNECTING MEANS [NEC 690.53] PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL 11 AT RAPID SHUTDOWN SWITCH [NEC 690.56(C)]. LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] LABEL 8 LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED BACKGROUND; “WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVE YELLOW BACKGROUND. [ANSI Z535] DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] PLAQUE AT POINT OF INTERCONNECTION; LABEL, SUCH AS LABEL 7 OR LABEL 8 MUST IDENTIFY PHOTOVOLTAIC SYSTEM [NEC 705.12(B)(4)] INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED NORTH SIDE OF THE HOUSE WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV SYSTEM DISCONNECTING MEANS. PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BATHROOMS [NEC 690.4(D),(E)] SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWICH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS LABEL 1 AT RAPID SHUTDOWN SYSTEM [NEC 690.56(C)(1)(A)]. ! WARNING ! ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPLOSED TO SUNLIGHT LABEL 2 AT EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.15] MAXIMUM VOLTAGE: 480 V DC MAXIMUM CIRCUIT CURRENT:45 A DC MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED):15 A DC ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND BE WEATHER RESISTANT/SUNLIGHT RESISTANT AND CANNOT BE HAND-WRITTEN PER NEC 110.21(B) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL 6 AT RAPID SHUTDOWN DISCONNECT SWITCH [NEC 690.56(C)(3)]. WARNING THIS SERVICE METER IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM #03-359 LOCAL CODES ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH ELECTRICAL LABELS PV-5 EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH ELECTRICAL PHOTOS PV-6 EMPIRE SOLAR GROUP 7003 EAST 47TH AVE DRIVE, UNIT A-400 DENVER, CO 80216 FOR INSTALLER USE ONLY ROJAS , VICTOR 522 DRIFTWOOD AVE ESTES PARK, COLORADO 80517 LICENSE # EC-0101114 ME: 1602 JOB #: 14927 DATE: 11/27/2020 DRAWN BY: MH OPTIMIZER MAP PV-7 N CAUTION POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN !! SERVICE 1 OF 1 SOLAR PHOTOVOLTAIC ARRAY 522 DRIFTWOOD AVE , ESTES PARK, COLORADO 80517 UTILITY METER MAIN SERVICE PANEL AC DISCONNECT INVERTER About Solaria Established in 2000, The Solaria Corporation has created one of the industry’s most respected IP portfolios, with over 100 patents encompassing materials, processes, applications, products, manufacturing automation and equipment. Headquartered in Fremont, California, Solaria has developed a technology platform that unlocks the potential of solar energy allowing it to be ubiquitous and universally accessed. The Solaria PowerXT AC Panel combines the latest cutting-edge microinverter technology from Enphase with the premium high-efficiency and superior aesthetics of the Solaria PowerXT Panel. Utilizing the latest Enphase IQ7+ platform the PowerXT AC Panel combines aesthetics and performance into an elegant product that reduces installation time by combining the inverter, panel and monitoring. Achieving 20% efficiency, Solaria PowerXT solar panels are one of the highest power AC panels in the residential solar market. Compared to conventional panels, Solaria PowerXT panels have fewer gaps between the solar cells; this leads to higher power and superior aesthetics. Solaria PowerXT Pure BlackTM residential panels are manufactured with black backsheet and frames, giving them a striking appearance. Higher Efficiency, Higher Power Solaria PowerXT panels achieve up to 20% efficiency; conventional panels achieve 15% – 17% efficiency. Combined with Enphase IQ7+ microinverter, the Solaria PowerXT AC Panel is one of the highest power and most efficient AC panels available. Easy to Install The integrated Enphase IQ7+ microinverter reduces installation costs due to fewer balance of system components, improved two-wire cabling and compliance with NEC 2014 & 2017 rapid shutdown requirements. Smart Grid Ready Meets CA Rule 21 and complies with advanced grid support, voltage and frequency ride- through requirements. Remotely updates to respond to changing grid requirments and is configurable for varying grid profiles. Improved Aesthetics Compared to conventional panels, the Solaria PowerXT AC Panel has a more uniform appearance and superior aesthetics. Durability and Reliability Industry leading 25 year warranty with a million hours of microinverter testing. The Solaria Corporation 1700 Broadway, Oakland, CA 94612 P: (510) 270-2500 www.solaria.com Copyright © 2019 The Solaria Corporation Product specifications are subject to change without notice. Rev 3C 08-15-2019 Solaria PowerXT®-365R-AC Solaria PowerXT® | AC Panel About Solaria Established in 2000, The Solaria Corporation has created one of the industry’s most respected IP portfolios, with over 65 patents encompassing materials, processes, applications, products, manufacturing automation and equipment. Headquartered in Oakland, CA, Solaria has developed a technology platform that unlocks the potential of solar energy. The Solaria Corporation 1700 Broadway, Oakland, CA 94612 P: (510) 270-2500 www.solaria.com Copyright © 2019 The Solaria Corporation Product specifications are subject to change without notice. Rev 3C 08-15-2019 Solaria PowerXT®-365R-AC DC Input Performance at STC (1000W/m2, 25° C, AM 1.5) Solaria PowerXT-355R-AC 365R-AC Max Power (Pmax)[W]355 365 Efficiency [%]19.6 20.2 Open Circuit Voltage (Voc)[V]47.4 48.0 Short Circuit Current (Isc)[A]9.53 9.58 Max Power Voltage (Vmp)[V]39.1 39.9 Max Power Current (Imp)[A]9.09 9.16 AC Output Data: Enphase IQ7+ Microinverter Peak Output Power [VA]295 Max Continuous Power [VA]290 Nominal Voltage [V]240 Max Continuous Current [A}1.21 Nominal Frequency [Hz]60 Extended Frequency Range [Hz]47-68 Peak Efficiency [%]97.5 Power Factor / Adjustable [#]0.85 leading...0.85 lagging Max Branch Circuit [A]20 Max Panels/Circuit [#]13 Operating Temperature [C]-40 to +65 Mechanical Characteristics Cell Type Monocrystalline Silicon Dimensions (L x W x H)1621mm x 1116mm x 40mm Weight 22 kg / 48 lbs Glass Type / Thickness AR Coated, Tempered / 3.2mm Frame Type Black Anodized Aluminum DC Cable Type / Length Q DC / 815(+), 740mm(-) AC Cable Type / Length Q AC / 2000mm Junction Box IP67 / 4 diodes Front Load 5400 Pa / 113 psf* Rear Load 3600 Pa / 75 psf* * Refer to Solaria Installation Manual for details Certifications / Warranty Certifications UL 1703/UL1741/CEC CAN/CSA-C22.2 NEMA 3R Fire Type Type 1 Power & Product Warranty 25 years* * Warranty details at www.solaria.com Packaging Stacking Method Horizontal / Palletized Pcs / Pallet 25 Pallet Dims 1668 x 1150 x 1230 mm Pallet Weight 615 kg / 1360 lbs Pallets / 40-ft Container 28 Pcs / 40-ft Container 700 IV Curves vs. Irradiance (365W Panel) Features Communication Power line Monitoring Enlighten Manager and MyEnlighten options Compatible with Enphase IQ Envoy Disconnecting Means Approved by UL for AC and DC load break as required by NEC Article 690 Rapid Shutdown Compliant per NEC-2014 & 2017 Comprehensive 25-Year Warranty 0 1 2 3 4 5 6 7 8 9 10 0 5 10 15 20 25 30 35 40 45 50 CU R R E N T ( A ) VOLTAGE (V) 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 Years 25-year workmanship and performance from Solaria Typical Tier 1 industry warranty 100% 90% 80% 98% 5 10 251520 86% 81% Wo r k m a n s h i p L i m i t IN V E R T E R S solaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Extremely small UL1741 SA certified, for CPUC Rule 21 grid compliance Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(3) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated (3) Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(5) -40 version P/N: SExxxxH-US000NNU4 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2019/V01/ENG NAM. Subject to change without notice. PO W E R O P T I M I Z E R solaredge.com PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 25 YEAR WARRANTY © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2019/V02/ENG NAM. Subject to change without notice. (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (7) It is not allowed to mix P405/P505 with P320/P340/P370/P400 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For SE14.4KUS/SE43.2KUS: It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter (3 strings per unit for SE43.2KUS) and when the maximum power difference between the strings is up to 1,000W (10) For SE30KUS/SE33.3KUS/SE66.6KUS/SE100KUS: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter (3 strings per unit for SE66.6KUS/SE100KUS) and when the maximum power difference between the strings is up to 2,000W Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cell modules) P370 (for higher- power 60 and 72-cell modules) P400 (for 72 & 96- cell modules) P405 (for thin film modules) P505 (for higher current modules) INPUT Rated Input DC Power(1)320 340 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125(2)87(2)Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 87 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3)Single or dual MC4(3)(4)MC4(3) Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(5) -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use the P405. In the case of an odd number of PV modules in one string, installing one P405 dual version power optimizer (5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details. PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase 208V Three Phase 480V Minimum String Length (Power Optimizers) P320, P340, P370, P400 8 10 18 P405 / P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(8) Maximum Power per String 5700 (6000 with SE7600-US - SE11400-US)5250 6000(9)12750(10)W Parallel Strings of Different Lengths or Orientations Yes SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICE With Superior Aesthetics CONCEALED UNIVERSAL CLAMPS 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty. TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2008, 14001:2004 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. UL2703 BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONLI S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702PUB2018AUG31 – PRINTED UPDATE SFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE SYSTEM BONDING & GROUNDING Q E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre-installed bonding pins which engage on the secure side of the MicrorailTM and splice. TRIMRAIL BONDING PATH: Trimrail to module bonding is accomplished with bonding clamp with integral bonding pin and bonding T-bolt. (refer also to alternate method ) N-S BONDING PATH: N-S module to module bonding is accomplished with bonding clamp with 2 integral bonding pins. (refer also to alternate method ) System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module at a location on the module specified by the module manufacturer. LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) • 10-32 mounting hardware • Torque = 5 ft-lb • AWG 4-14 - Solid or Stranded LUG DETAIL & TORQUE INFO Ilsco Flange Lug(SGB-4) • 1/4” mounting hardware • Torque = 75 in-lb • AWG 4-14 - Solid or Stranded LUG DETAIL & TORQUE INFO Wiley WEEBLug (6.7) • 1/4” mounting hardware • Torque = 10 ft-lb • AWG 6-14 - Solid or Stranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION TERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs WEEBLUG Single Use Only Star Washer is Single Use Only  Alternate method Alternate method SFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE UL CODE COMPLIANCE NOTES R SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to the system level fire portion of UL 1703. This UL 1703 classification has been incorporated into the UL 2703 product certification. SFM has achieved Class A, B & C system level performance for low slope & steep sloped roofs when used in conjunction with type 1 and type 2 modules. Class A, B & C system level fire UL2703 TEST MODULES See page "S" for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 22.3 sqft • UL2703 Design Load Ratings: a) Downward Pressure – 113 PSF / 5400 Pa b) Upward Pressure – 50 PSF / 2400 Pa c) Down-Slope Load – 30 PSF / 1400 Pa • Tested Loads: a) Downward Pressure – 170 PSF / 8000 Pa b) Upward Pressure – 75 PSF / 3500 Pa c) Down-Slope Load – 45 PSF / 2100 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span LABEL MARKINGS • System fire class rating: See installation instructions for installation requirements to achieve a specified system fire class rating with Unirac . • Unirac SUNFRAME MICRORAILTM is listed to UL 2703. • All splices within a system are shipped with marking indicating date and location of manufacture. Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Required performance is inherent in the SFM design, and no additional mitigation measures are required. The fire classification rating is valid for any roof pitch. There is no required minimum or maximum height limitation above the roof deck to maintain the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILTM components shall be mounted over a fire resistant roof covering rated for the application. SFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE MODULE MAINTENANCE T REMOVE 2" CAPS: 1.Remove capbolt 2. Separate cap from base by moving east/west 3. Remove cap REMOVE 8" CAPS: 1.Remove (2) cap bolts 2. Separate cap from base by moving east/west 3. Remove cap SLIDE FLOATING SPLICE: 1. Loosen (3) cap bolts approx. 3 turns. 2. Slide entire floating splice away from module being removed. Bonding note: If both sides of array are bonded with NS Bonding Clips, as recommended, then no additional bonding is required for module maintenance. If necessary, on the row of modules containing the module being removed, one additional bonding clip can be added to the edge of the array opposite of the edge with bonding clips already installed. This is only necessary when the module removal would break the bonding path.    CAUTION: DO NOT FULLY REMOVE FASTENERS              LIFT MODULE AND DISCONNECT MLPE CABLES REMOVE MODULE. REVERSE STEPS TO REPLACE MODULE REMOVED SFM SUNFRAMEMICRORAIL™INSTALLATION GUIDE PAGE CONSIDERATIONS & MAINTENANCE U ELECTRICAL CONSIDERATIONS SUNFRAME Microrail is intended to be used with PV modules that have a system voltage less than or equal to that allowable by the NEC. A minimum 10AWG, 105°C copper grounding conductor should be used to ground a system, according to the National Electric Code (NEC). It is the installer’s responsibility to check local codes, which may vary. INTERCONNECTION INFORMATION There is no size constraint beyond structural thermal expansion limits on how many SUNFRAME Microrails & PV modules can be mechanically interconnected for any given configuration, provided that the installation meets the requirements of applicable building and fire codes. GROUNDING NOTES The installation must be conducted in accordance with the National Electric Code (NEC) and the authority having jurisdiction. Please refer to these resources in your location for required grounding lug quantities specific to your project. The grounding / bonding components may overhang parts of the array so care must be taken when walking around the array to avoid damage. Conductor fastener torque values depend on conductor size. This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instruction PERIODIC INSPECTION Conduct periodic inspections for loose components, loose fasteners or any corrosion, immediately replace any affected components. UNIRAC INC. LETTER REPORT SCOPE OF WORK ADDITION OF MODULES TO THE UNIRAC SFM CDR 102393982LAX-002 REPORT NUMBER 104430210LAX-001a ISSUE DATE 24-Sept-2020 PAGES 3 DOCUMENT CONTROL NUMBER GFT-OP-10a (21-June-2019) © 2019 INTERTEK LETTER REPORT 25791 Commercentre Drive Lake Forest, CA 92630 Telephone: 949-448-4100 Facsimile: 949-448-4111 www.intertek.com This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Version: 6-March-2017 Page 2 of 3 GFT-OP-10a September 24, 2020 Intertek Report No. 104430210LAX-001a Intertek Project No. G104430210 Klaus Nicolaedis Ph: 505-462-2190 Unirac Inc. 1411 Broadway Blvd NE Albuquerque, NM 87102-1545 USA klaus.nicolaedis@unirac.com Subject: Addition of modules to the Unirac SFM CDR 102393982LAX-002 Dear Klaus, This letter report represents the results of our evaluation of the above referenced product(s) to the requirements contained in the following standards: Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1] SECTION 1 SUMMARY This investigation was authorized by quote # Qu-01101732 dated 08-17-2020. The scope of the project was to evaluate and add module frames to the SFM CDR 102393982LAX-002. SECTION 2 EVALUATION The following PV modules were evaluated for bonding/grounding purposes and are approved to be installed using the Unirac SFM model: Manufacturer Model Hanwha Q Cell Q.PEAK DUO L-G7, Q.PEAK DUO L-G7.1, Q.PEAK DUO L-G7.2, Q.PEAK DUO L-G7.3, Q.PEAK DUO L-G8, Q.PEAK DUO L-G8.1, Q.PEAK DUO L-G8.2, Q.PEAK DUO L-G8.3 REC TP3M, TP3M Black Silfab SIL-xxx-NT, SIL-xxx-ML, SIL-xxx-NL, SIL-xxx-BL, SIL-xxx-HL LETTER REPORT Unirac Inc. Intertek Report No: 104430210LAX-001a Version: 6-March-2017 Page 3 of 3 GFT-OP-10a SECTION 3 PROJECT STATUS & ACTION Issuance of this letter report provides results of the evaluation covered by Intertek Project No. G104430210. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact your dedicated Intertek Project Manager. Completed by: Abhinav Prakash Reviewed by: Adam Muliawan Title: Project Engineer Title: Reviewer Signature: Signature Date 09-24-2020 Date: 09-25-2020 Please note: this Letter Report does not represent authorization for the use of any Intertek certification marks. March 12 20 6 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 F 916.961.3965 W www.pzse.com Experience | Integrity | Empowerment AUTHORIZATION TO MARK Applicant: Address: Country: Contact: Phone: FAX: Email: Standard(s): Product: Brand Name: Models: This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] LTR AE-001-2012 Issued: 2012/10/23 Photovoltaic Module Racking Systems; Attachements 1 - 3 Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019JUN17 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Unirac SFM Unirac Control Number:5003705 Authorized by: for Dean Davidson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. klaus.nicolaedis@unirac.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:Lake Forest, CA U.S.A. Klaus Nicolaedis 505-462-2190 NA Unirac, Inc 1411 Broadway Blvd NE Albuquerque, NM 87102 USA This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Page 1 of 2 ATM for Report 102393982LAX-002 ATM Issued: 21-Oct-2019 ED 16.3.15 (20-Apr-17) Mandatory AUTHORIZATION TO MARK Applicant: Address: Country: Contact: Phone: FAX: Email: Standard(s): Product: Brand Name: Models: Unirac, Inc 1411 Broadway Blvd NE Albuquerque, NM 87102 USA Klaus Nicolaedis 505-462-2190 NA klaus.nicolaedis@unirac.com Party Authorized To Apply Mark:Same as Manufacturer Report Issuing Office:Lake Forest, CA U.S.A. Control Number:5014989 Authorized by: for Dean Davidson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. Unirac SFM This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] LTR AE-001-2012 Issued: 2012/10/23 Photovoltaic Module Racking Systems; Attachements 1 - 3 Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev PUB2019JUN17 with Annex North Row Extension Installation Guide Rev PUB2019FEB20 Unirac This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Page 2 of 2 ATM for Report 102393982LAX-002 ATM Issued: 21-Oct-2019 ED 16.3.15 (20-Apr-17) Mandatory Listing Constructional Data Report (CDR) Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 13-May-2020 Standard(s) Applicant Manufacturer 2 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 3 Address Country Contact Phone FAX Email 505-462-2190 505-843-1418 NA klaus.nicolaedis@unirac.com toddg@unirac.com 1411 Broadway Blvd NE Albuquerque, NM 87102 USA Klaus Nicolaedis Todd Ganshaw 1.0 Reference and Address Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1] Photovoltaic Module Racking Systems [CSA LTR AE-001:2012 Ed.2012/10/23] Unirac, Inc Page 1 of 113 Report No. 102393982LAX-002 Unirac, Inc Page 2 of 113 Issued: 11-Apr-2016 Revised: 13-May-2020 Product Brand name 2.0 Product Description Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2020MAY04 Unirac Description The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground. The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame (at bottom flange) to contact the metal, creating a bonded connection from module to module. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the revision in effect in the jurisdiction in which the project resides. Any local electrical codes must be adhered in addition to the national electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same engage cable. ED 16.3.15 (20-Apr-17) Mandatory Report No. 102393982LAX-002 Unirac, Inc Page 3 of 113 Issued: 11-Apr-2016 Revised: 13-May-2020 2.0 Product Description Models Model Similarity Other Ratings Unirac SFM NA Fuse Rating: 30A Module Orientation: Portrait or Landscape Maximum Module Size: 17.98 ft² UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope Tested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading Increased size ML test: Maximum Module Size: 22.3 ft² UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope LG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift Fire Class Resistance Rating: - Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5” gap between the bottom of the module and the roof’s surface See section 7.0 illustractions # 1, 1a, 1aa, and 1ab for a complete list of PV modules evaluated with these racking systems Ratings NA ED 16.3.15 (20-Apr-17) Mandatory Product data sheet Characteristics D222NRB Safety switch, general duty, fusible, 60A, 2 poles, 15 hp, 120 VAC, NEMA 3R, bolt-on provision, neutral factory installed Product availability : Stock - Normally stocked in distribution facility Price* : 326.00 USD Main Product Single Throw Safety Switch Current Rating 60 A Certifications UL listed file E2875 Enclosure Rating NEMA 3R Disconnect Type Fusible disconnect switch Factory Installed Neutral Neutral (factory installed) Short Circuit Current Rating 100 kA maximum depending on fuse H, K or R Mounting Type Surface Number of Poles 2 Electrical Connection Lugs Duty Rating General duty Voltage Rating 240 V AC Wire Size AWG 12...AWG 3 aluminium AWG 14...AWG 3 copper Complementary Maximum Horse Power Rating 1.5 hp 120 V AC 60 Hz 1 phase NEC 240.6 3 hp 120 V AC 60 Hz 3 phase NEC 430.52 3 hp 240 V AC 60 Hz 1 phase NEC 240.6 7.5 hp 240 V AC 60 Hz 3 phase NEC 240.6 10 hp 240 V AC 60 Hz 1 phase NEC 430.52 15 hp 240 V AC 60 Hz 3 phase NEC 430.52 Tightening torque 35 lbf.in (3.95 N.m) 0.00…0.01 in² (2.08…5.26 mm²) AWG 14...AWG 10) 35 lbf.in (3.95 N.m) AWG 14...AWG 10) 45 lbf.in (5.08 N.m) 0.01 in² (8.37 mm²) AWG 8) 45 lbf.in (5.08 N.m) 0.02…0.03 in² (12.3…21.12 mm²) AWG 6...AWG 4) 50 lbf.in (5.65 N.m) 0.04 in² (26.67 mm²) AWG 3) Di s c l a i m e r : T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s *  Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Jan 26, 2021 1 Height 14.88 in (377.95 mm) Width 7.45 in (189.23 mm) Depth 4.87 in (123.70 mm) Ordering and shipping details Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A GTIN 00785901460640 Nbr. of units in pkg.1 Package weight(Lbs)8.25 lb(US) (3.74 kg) Returnability Yes Country of origin US Packing Units Unit Type of Package 1 PCE Package 1 Height 5.20 in (13.208 cm) Package 1 width 7.70 in (19.558 cm) Package 1 Length 16.20 in (41.148 cm) Unit Type of Package 2 PAL Number of Units in Package 2 120 Package 2 Weight 1022.00 lb(US) (463.571 kg) Package 2 Height 45.00 in (114.3 cm) Package 2 width 40.00 in (101.6 cm) Package 2 Length 48.00 in (121.92 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration REACh free of SVHC Yes EU RoHS Directive Compliant EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Product out of China RoHS scope. Substance declaration for your information. Environmental Disclosure Product Environmental Profile PVC free Yes Contractual warranty Warranty 18 months 2 Product data sheet Dimensions Drawings D222NRB Approximate Dimensions 3 Product data sheet Connections and Schema D222NRB Connections and Wiring Diagrams 4