GENERAL NOTES:
1. EXISTING DECK BEAMS, POSTS, FOUNDATIONS ARE TO REMAIN UNCHANGED. EXISTING
DECKING, DECK JOISTS, AND RAILING ARE TO BE REMOVED AND REPLACED.
2. NEW DECK JOISTS SHALL BE SOUTHERN YELLOW PINE #1 OR BETTER AND SHALL BE PRESSURE
TREATED.
3. DECKING SHALL BE 1x6 ENGINEERED COMPOSITE DECKING.
4. EXISTING DECK BEAMS SHALL BE INSPECTED WHEN EXISTING DECKING IS REMOVED AND IF
DETERIORATION IS NOTED, THE BEAMS SHOULD BE REPLACED WITH EQUAL SIZE AND PRESSURE TREATED
LVL MATERIAL WITH 2.0E MINIMUM STRENGTH DESIGNATION.
5. ADD SIMPSON H2.5 AT EACH JOIST TO DROPPED BEAMS AND FULL DEPTH BLOCKING BETWEEN JOISTS
OVER DROPPED BEAMS.
6. SIMPSON CONNECTION HARDWARE SHALL BE INSTALLED WITH THE RECOMMENDED SIMPSON CONNECTOR
SIZES AND QUANTITIES (NAILS, SCREWS, BOLTS) AS LISTED IN THE SIMPSON WOOD CONSTRUCTION CONNECTOR MANUAL.
7/8/2024
PERMIT #24-EP-00265
Field Copy
Print out legibly & in color and have on-site for inspector
REVIEWED BY SAFEbuilt - 7/18/2024 - BY PBland
OPEN HOLE INSPECTION REQUIRED FOR DEPTH & SIZE OF CAISSONS/PIERS - BEFORE CONCRETE IS POURED
Guardrail is required for deck walking surfaces that are 30" or
more above grade
Guardrails and the support of the Guardrail shall be
constructed per R507.10 of the 2021 IRC
In accordance with Manufacturers installation requirementsPlastic Composite
Engineered Lumber shall be listed and labeled for outdoor use or wrapped to protect from weather
ALL BEAM/JOIST SPLICES MUST OCCUR OVER POST/SUPPORT WITH 1 1/2" BEARING
Connectors & fasteners in contact with preservative-treated wood shall be of hot dipped, zinc coated galvanized
steel, stainless steel, silicone bronze or copper
PLANS AND CONSTRUCTION SHALL MEET THE 2021 IRC AND
ALL APPLICABLE MUNICIPAL CODES & ORDINANCES
Issuance of a permit or approval of these construction documents
shall not be construed to be a permit for, or an approval of, any
violation of any of the provisions of the adopted codes or of other
ordinances of this jurisdiction.
A permit presuming to give authority to violate or cancel the
provisions of these codes shall be invalid. R105.4
APPROVED by SAFEbuilt;
2021 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
07/18/2024
Provide to inspector - wildfire mitigation plan