Loading...
HomeMy WebLinkAboutPLANS 1505 Deer Path Ct Residence 2019-03-16scale 1/4"=1'-0" Front Elevation Firs t Floor Plan Second Floor Plan scale 1/4"=1'-0" Rear E levation scale 1/4"=1'-0" Right Side Elevation scale 1/4"=1'-0" Left Side Elev ation North Elevation Bas ement Plan Floor Plan Main Floor Plan U pper Floor Plan scale 1/4"=1'-0" South Elev ation scale 1/4"=1'-0" Eas t Elev ation scale 1/4"=1'-0" West Elevation Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Framing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan GENERAL NOTES 1.DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS - MAY NOT BE PRINTED TO SCALE 2.ENGINEERING DRAWINGS, NOTES AND SPECIFICATIONS TAKE PRECEDENCE OVER THESE PLANS. 3.ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODE, REGARDLESS OF WHAT IS, OR IS NOT ON THIS SET OF PLANS. 4.PLANS ARE INTENDED TO CONFORM TO INTERNATIONAL RESIDENTIAL CODE 2015, DESIGNER (NAMAQUA BLUEPRINT LLC - TODD WILDERMAN) MAKES NO GUARANTEE OF COMPLIANCE AND IS NOT RESPONSIBLE FOR CONSTRUCTION COMPLIANCE OR SUPERVISION. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL APPLICABLE CODE AND MAKE ADJUSTMENTS AS NECESSARY TO MAINTAIN COMPLIANCE. USE OF THESE PLANS IMPLIES AGREEMENT WITH THIS STATEMENT. 5.DIMENSIONS ARE TO FACE OF STUD. EXTERIOR WALLS TO BE 2X6, INTERIOR 2X4 UNLESS NOTED OTHERWISE. 6. WALL BEHIND CLOTHES DRYER TO BE 2X6 7. FOUNDATION DESIGN, STRUCTURAL SPECIFICATIONS, BEAMS, CONNECTIONS, FOUNDATION DRAIN, SITE DRAINAGE, LOAD CALCULATIONS, WIND LOAD, SNOW LOAD, FLOOR AND ROOF LOAD, SOIL BEARING CAPACITY, SOIL EXPANSION ETC. TO BE PER LICENSED ENGINEER. ALL NOTATIONS AND SPECIFICATIONS ON THESE PLANS ARE FOR REFERENCE AND COMMUNICATION. ENGINEERING SPECIFICATIONS TAKE PRECEDENCE REGARDLESS OF WHAT IS OR IS NOT ON THIS SET OF PLANS. 8. WINDOWS - BRAND TO BE DETERMINED - ALL WINDOWS WITHIN 24" OF DOORS, INSTALLED AT STAIRWAYS, INSTALLED NEXT TO BATH TUBS OR IN SHOWERS, AND ANY PANE OVER 9 SQ.FT., SHALL HAVE TEMPERED GLASS. WINDOW SUPPLIER AND CONTRACTOR TO VERIFY. 9. EGRESS - WINDOWS IN BEDROOMS OR OTHER HABITABLE ROOMS, SHALL HAVE EGRESS OPENING OF A MINIMUM OF 5.7 SQ.FT., MINIMUM WIDTH OF 20", MINIMUM HEIGHT OF 24", NOT MORE THAN 44" ABOVE ADJACENT FLOOR. BASEMENT WINDOWS SHALL HAVE APPROPRIATE EGRESS WINDOW WELL AND EGRESS LADDER WHEN THE BOTTOM OF THE WINDOW WELL IS MORE THAN 44" BELOW GRADE. 10. ALL MECHANICAL AND HEATING EQUIPMENT TO BE INSTALLED PER CODE. PROVIDE APPROPRIATE EXHAUST VENT AND COMBUSTION VENTING. CONSULT CODE. SERVICE DESCRIPTION NAMAQUA BLUEPRINT LLC, WILDERMAN DESIGNS, TODD WILDERMAN (DESIGNER) PROVIDES ARCHITECTURAL DESIGN AND DRAFTING FOR ALLOWED PROJECTS PER COLORADO STATUTE. THE INTENT OF THIS SERVICE IS TO PROVIDE OVERALL CONCEPT COMMUNICATION. EXACT SPECIFICATIONS MAY VARY FROM WHAT IS ON THE PLANS AND IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND/OR CLIENT TO VERIFY AND ADJUST AS NEEDED. PROJECTS REQUIRING PROFESSIONAL ENGINEERING OR OTHER PROFESSIONAL SERVICE SHALL HAVE DRAWINGS AND SPECIFICATIONS PROVIDED BY ASSOCIATED PROFESSIONALS IN THESE FIELDS OF SERVICE. CONTRACTOR OR CLIENT SHALL COORDINATE INFORMATION AND ADJUST AS NEEDED. DESIGNER MAKES NO CLAIM OF ACCURACY OR EXACTNESS AND THE PROJECT SHALL BE ASSEMBLED ACCORDING TO ALL APPLICABLE CODE, REGARDLESS OF WHAT IS, OR IS NOT ON THIS SET OF PLANS. CLIENT UNDERSTANDS THAT THERE IS NO ARCHITECTURAL STAMP OR LICENSE ASSOCIATED WITH THESE PLANS. CLIENT AND CONTRACTOR WILL INDEMNIFY AND HOLD DESIGNER HARMLESS FROM ANY AND ALL CLAIMS AS A RESULT OF THE USE OF THESE PLANS. THESE PLANS AND THE ASSOCIATED DESIGN ARE THE PROPERTY OF THE DESIGNER AND SHALL NOT BE USED OR TRANSFERRED WITHOUT EXPRESS PERMISSION OF DESIGNER. 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -1 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com A-1 Cover Sheet A-2 Elevations 1,2 A-3 Elevations 3,4 A-4 Elevations 5,6 A-5 Elevations 7,8 A-6 Main Floor Plan A-7 Upper Floor Plan A-8 Section Detail A A-9 Section Details F,H,J A-10 Section Details B,C,G A-11 Section Detail E A-12 Section Detail D - Door and Window Schedules A-13 Main Floor Electrical Plan A-14 Upper Floor Electrical Plan A-15 Timber Truss Details A-16 Roof Plan Sheet Index ZZ ii mm mm eerrmm aann RR eess ii ddeenn cc ee Firs t Floor Plan Second Floor Plan scale 1/4"=1'-0" Rear E levation scale 1/4"=1'-0" Right Side Elevation scale 1/4"=1'-0" Left Side Elev ation North Elevation Bas ement Plan Floor Plan scale 1/4"=1'-0" South Elev ation scale 1/4"=1'-0" Eas t Elev ation scale 1/4"=1'-0" West Elevation Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Framing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Lower Floor Plan scale 1/4"=1'-0" Elev ation-2 scale 1/4"=1'-0" Elev ation-1 12 14 6 12 4 12 12 14 12 14 12 14 12 14 12 14 75 15/16" 162 5/16" 10 1/4" 109 1/8" 3'-4 5/16" 5'-2 3/8" Ridge 23.47' Highest Ridge 29.80' Top of Subfloor - 2nd Floor 9.95' Rough Ceiling - 1st Floor 9.09' Top of Subfloor - 1st Floor 0.00' W23 D30D02 W22 W32W24 W31 W09 D24 W09 W16 W17 W20 W20 W21 W11W11 W03 STONE VENEER 12 14 12 14 182 1/16" 10 1/4" 109 1/8" 75 15/16" 162 5/16" 10 1/4" 109 1/8" Top of Subfloor - 2nd Floor 9.95' Ridge 25.12' Rough Ceiling - 1st Floor 9.09' Top of Subfloor - 1st Floor 0.00' Ridge 23.47' Highest Ridge 29.80' Top of Subfloor - 2nd Floor 9.95' Rough Ceiling - 1st Floor 9.09' Top of Subfloor - 1st Floor 0.00' D30D02 W13W32W24W30 W09 W16 W20 W21 W11W11 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -2 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com M AIN F LOO R 2418 S.F. scale 1/4"=1'-0" Front Elevation Firs t Floor Plan Second Floor Plan scale 1/4"=1'-0" Rear E levation scale 1/4"=1'-0" Right Side Elevation scale 1/4"=1'-0" Left Side Elev ation North Elevation Bas ement Plan Floor Plan Main Floor Plan Upper Floor Plan scale 1/4"=1'-0" South Elev ation scale 1/4"=1'-0" Eas t Elev ation scale 1/4"=1'-0" West Elevation Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Framing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan 12 14 4 12 D30D02 W24W30 W01D31D27 W28 W05D25 W18 W04 W16 W20 W19 12 14 W01D31D31D27 W10W26W10 W33 W07 W25 W27 W28 W05D25 W18 W04 W14 W19 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -3 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com M AIN F LOO R 2418 S.F. scale 1/4"=1'-0" Elev ation-4 scale 1/4"=1'-0" Elev ation-3 Bas ement Plan Main Floor Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan 12 14 12 14 12 14 10 12 4 12 W23W23 W29 D28W06W08 W12 W02 W20 W20 10 12 4 12 12 14 W23 W29 W01 D21 D31 W10W26W10 D29 W33 W07 W25 W27 W05D25 W18 W04 W14 W20 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -4 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com scale 1/4"=1'-0" Elev ation-5 scale 1/4"=1'-0" Elevation-6 Bas ement Plan Main Floor Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan scale 1/4"=1'-0" Elev ation-8 12 14 12 14 10 12 4 12 139 5/8" 98 5/8" 10 1/4" 109 1/8" 182 1/16" 10 1/4" 109 1/8" Rough Ceiling - 2nd Floor 18.17' Highest Ridge 29.80' Top of Subfloor - 2nd Floor 9.95' Rough Ceiling - 1st Floor 9.09' Top of Subfloor - 1st Floor 0.00' Ridge 25.12' Top of Subfloor - 2nd Floor 9.95' Rough Ceiling - 1st Floor 9.09' Top of Subfloor - 1st Floor 0.00' W23 W29 D31 W10W26W10D28 D29 W06W08 W12 W02 W07 W25 W27W20 W23 W22 W06 W09 W12W17 W20 W21 W11W11 Outdoor Kitchen/Fireplace 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -5 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com scale 1/4"=1'-0" Elev ation-7 Bas ement Plan scale 1/4"=1'-0" Main Floor Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan B24R SB36 B39 DW24 B4212 B4212 B39 B3912 B3912 B30 B30 B15R SB27L SB27R B18R SB27L SB27R B21L B21R SB24R B24R SB36 B39 DW24 B4212 B4212 B39 B3912 B3912 B30 B30 B15R SB27L SB27R B18R SB27L SB27R B21L B21R SB24R U242490R U482490 W3036 W3036 W 2736 W 3036 W 3036 Secret Door Bookcase W23W23 W23W23 D30D30 D02D02 W13W13 W29W29 W22W22 W32W32 W24W24 W30W30 W01W01 D21D21 D06D06 D16D16 D33D33 D01D01 W31W31 D31D31 D31D31 D27D27 W10W10 W26W26 W10W10 D28D28 D29D29 W06W06 W08W08 W33W33 D07D07 3668 D11D11 W09W09 D24D24 W09W09 D15D15 D34D34 D14D14 D22D22 D12D12 D03D03 4668 D19D19 D04D04 UPUP LVL Beam dropped 8x10 Beam 10x12 Beam 6x12 Beam 6x12 Beam 10x12 Beam 10x12 Beam 10x12 Beam 6x10 Beam 6x10 Beam LVL Beam dropped 6x6 Post 6x6 Post 6x6 Post 6x6 Post 6x6 Post 10x10 Post10x10 Post10x10 Post 10x10 Post 10x10 Post E1E1 Elevation 1 E2E2Elevation 2 E3E3Elevation 3 E4E4 Elevation 4 E5E5 Elevation 5 E6E6 Elevation 6 E7E7 Elevation 7 E8E8 Elevation 8 2'-10" 2'-5 7/8" 2'-10"2'-2" 4'-2" 5'-1" 6'-1 1/2" 4'-7 7/16"2'-2 9/16"7'-9"12'-4"7'-9"5'10' 49'-8" 4'-7 3/8" 4'-8" 7'-11" 7'-11" 9'-3 3/8" 15'-10" 10' 4' 39'-1 3/8" 7' 14' 2' 5' 8'-1 1/2" 5'-10 1/2" 7' 2' 4'-4" 9'-4" 4'-4" 6'-4 3/4" 5'-5" 2' 18' 2' 1'-2" 9' 1'-10" 11'-9 3/4" 22' 12' 12' 12' 2' 24' 2' 28' 7'-10" 4'-2 15/16" 4' 7'-2 5/8" 2'-11 7/8" 12'-0 15/16" 4'-2" 3'-2 3/8" 11' 11' 12' 22' 6'-6" 5'-3 7/8" 45'-9 7/8" 4'-2" 3'-10"8' 2'-7 1/2" 8'-10" 2'-6" 4'-6" 4'-6" 6'-2 3/4" 13'-11 1/2" 9' 29'-2 1/4" 2' 5' 6'-4 1/4" 4'-7 1/2" 8'-4 1/4"5'-3 3/4"3'6'6'3'6'-0 3/4"11'-11 1/4" 13'-8"18'18' 49'-8" 11'-5" 6'-2 13/16" 17'-7 13/16" 9' 30' 5' 4'-6" 4'-6" 9' 5'5' 6'-6 1/2" 7'-5" 2'-4" 2'-11 1/2" 4'-2 1/2" 6'-6 1/2" 5'-5 1/2" 1'-3" 2'-10"3'-4 1/2"2'-7"1'-3 1/2" 4'-0 1/2" 29'-7 13/16" 1'-10" 2'-3 1/2" 9'-6 1/2" 4'-8 1/2"4'-10" 4'-4" 3'-9 3/4" 6'-9 1/4" 4'-2" 10 3/4" 6'-2" 5'-4 1/2"1'-8" 5'-8 1/2" 10" 4' 8" 12'-10 1/2"6'-11 1/4" 1 3 5 ° 135°1 3 5 ° 135° 87 sq ft 379 sq ft 158 sq ft 106 sq ft 222 sq ft 2418 sq ft 202 sq ft 109 sq ft 54 sq ft 56 sq ft 893 sq ft 34 sq ft 145 sq ft 54 sq ft 21 sq ft 249 sq ft 167 sq ft 245 sq ft 133 sq ft 18 sq ft 25 sq ft Garage Living Area Porch Closet Library Master Bdrm Master Bath Shower Bedroom 2 Bath 2 Hall PDR Laundry Utility Pantry Entry/Stair Hall Living Kitchen Dining Closet A A-8 A A-8 A A-8 A A-8 B A-10 B A-10 B A-10 B A-10 G A-10 G A-10 G A-10 G A-10 D A-12 D A-12 D A-12 D A-12 E A-11 E A-11 F A-9 F A-9 F A-9 F A-9 C A-10 C A-10 C A-10 C A-10 H A-9 H A-9 H A-9 H A-9 11 FLAT CEILING 8' 22 FLAT CEILING 9' 33 VAULTED CEILING 44 5/8" GYP CEILING FINISH 55 T&G PINE OVER 5/8" GYP CEILING FINISH 66 WOOD FLOOR 77 TILE FLOOR 88 CARPET 99 22x22 SKYLIGHT 1010 5/8" TYPE X GYP WALLS AND CEILING 1111 not used 1010 1010 66 66 66 66 66 66 66 66 77 77 88 88 22 22 22 22 22 22 22 22 22 77 77 66 66 22 66 33 33 33 33 22 55 J A-9 J A-9 J A-9 J A-9 Door and Window Schedules on Sheet A-12 G AS BO ILER FO R H EAT AN D H O T W ATER 5/8" TYPE X GYP WALLS AND CEILING ENTIRE GARAGE SOLID CORE FIRE DOOR W/ CLOSER GAS RANGE W/ VENT HOOD GAS LINE FOR BBQ AND OUTDOOR FIREPLACE GAS LINE FOR FIREPIT G AS FIR EPLAC E 22 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -6 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com Bas ement Plan scale 1/4"=1'-0" Upper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan W03 W19 DNDN B18R SB27L SB27R B30 SB24L SB24R B26R SB27L SB27R B18R SB27L SB27R B30 SB24L SB24R B26R SB27L SB27R W12W12 W02W02 W07W07 W25W25 W27W27 W28W28 W05W05 D25D25 W18W18 W04W04 W16W16 W14W14 W17W17 W20W20 W20W20 W20W20W21W21 W11W11W11W11 4068 D13D13 D08D08 D35D35 D18D18 D20D20 D23D23 D26D26 D32D32 D17D17 D09D09 D10D10 D36D36 RIDGE BEAM TIMBER TRUSS ONE TIMBER TRUSS ONE TIMBER TRUSS ONE CEILING BEAM CEILING BEAM TIMBER TRUSS TWO TIMBER TRUSS TWO CEILING BEAM ATTIC ACCESS 22x30 LVL FLUSH 6x12 Beam 6x12 Beam E1E1 Elevation 1 E2E2Elevation 2 E3E3Elevation 3 E4E4 Elevation 4 E5E5 Elevation 5 E6E6 Elevation 6 E7E7 Elevation 7 E8E8 Elevation 8 3'-10 1/2"3'-10 1/2"6'-2"6'-2"3'-10 1/2"3'-10 1/2" 2'-1 1/2" 1'-9" 6' 6'-10"7'-9"12'-4"7'-9" 3'-2 3/8" 3'-0 1/2" 4'-11 1/2" 9' 6'-2 7/8" 13'-11 1/2" 20'-2 3/8" 9' 5' 9'-1 3/16" 5'-10 13/16" 5'-10 13/16" 9'-1 3/16" 8'-4"5'-4"9'9'6'-0 3/4"11'-11 1/4" 13'-8"18'18' 49'-8" 11'-5" 6'-2 13/16" 9' 17'-7 13/16" 12'-4 3/16" 5' 44' 4'-11 1/2" 6'-2" 5' 4'-7 3/8" 3'-8" 8'-3 3/8" 1' 2'-1 1/2" 11'-7" 2'-1 1/2" 10' 4' 11'-4 3/8" 11'-8" 16'-1" 7' 14' 7' 5'-6" 5'-6" 5'-6" 11' 5'-6" 12' 22' 8' 4'-8" 4'-8" 5'-10" 2' 4'-4" 9'-4" 4'-4" 5'-6" 5'-6" 5'-6" 11' 5'-6" 6'-6" 6'-6" 5'-6" 13' 5'-6" 28' 5'-9 1/2" 5'-9 1/2" 4' 3'-9" 8'-4 1/2" 11'-7" 5'-11 5/16" 11'-8 3/16" 22' 12' 2' 24' 2' 6'-6" 5' 6'-7" 7'-1 1/2" 6'-3 1/2" 3'-7" 4'-4" 3'-6 1/2" 4'-5 1/2" 6'-10 1/2" 2'-3 1/2"3'-6"9'-8 1/2" 5'4'-8 1/2" 7'-3 3/4" 6'-7 3/4" 5'-1 3/4" 4'-6"2'-10 1/2" 6'-6 3/4" 1'-4" 8'-9" 6'-4" 5'-5" 7'-6" 5'-3 1/2" 3'-5" 3'-8 3/16" 3'-3" 1'-3" 4'-1" 5'-4" 7'-2"10'-0 1/2"10'-0 1/2"6'-11" 2'-4 3/4" 5' 3'-9" 4'-1" 545 sq ft 197 sq ft 241 sq ft 61 sq ft 38 sq ft 103 sq ft 103 sq ft 37 sq ft 638 sq ft 69 sq ft 49 sq ft 1240 sq ft 15 sq ft 217 sq ft 53 sq ft 257 sq ft 119 sq ft 28 sq ft 18 sq ft 21 sq ft 46 sq ft 35 sq ft 23 sq ft 19 sq ft 21 sq ft 13 sq ft 96 sq ft Open Below Open Below Attic Attic Attic Attic Closet Attic Attic Living Area Bridge Bonus Room Shower Bath 5 Bedroom 4 Bath 4 Bedroom 3 Bath 3 Deck Shower Room Bath 5 Attic Attic Linen Bedroom 4 33 33 33 11 33 55 11 11 33 22 33 33 33 88 88 77 77 77 77 77 77 66 66 88 33 33 99 99 99 66 66 88 VAULTED TRUSSES 4:12 PITCH 11 Shower Hall A A-8 A A-8 A A-8 A A-8 B A-10 B A-10 B A-10 B A-10 G A-10 G A-10 G A-10 G A-10 D A-12 D A-12 D A-12 D A-12 E A-11 E A-11 F A-9 F A-9 F A-9 F A-9 C A-10 C A-10 C A-10 C A-10 J A-9 J A-9 J A-9 J A-9 11 FLAT CEILING 8' 22 FLAT CEILING 9' 33 VAULTED CEILING 44 5/8" GYP CEILING FINISH 55 T&G PINE OVER 5/8" GYP CEILING FINISH 66 WOOD FLOOR 77 TILE FLOOR 88 CARPET 99 22x22 SKYLIGHT 1010 5/8" TYPE X GYP WALLS AND CEILING 1111 not used Door and Window Schedules on Sheet A-12 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -7 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com scale 1/2"=1'-0" Section Detail A Bas ement Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan 12 14 4 12 19'-9" 10'-1 3/4" 5'-1 5/16" 3'-4 9/16" 6 11/16" 1' W22 D31D19 W28 W14 W17 D18 W19 J A-9 J A-9 J A-9 J A-9 2x6 RAFTER EXTENSION TRUSS CLIP 2x10 ROLL BLOCKING 2x6 SUB-FASCIA 2x12 FASCIA GUTTER 2x8 SHADOW BOARD DRIP EDGE FLASHING PLY SOFFIT DOUBLE 2x6 TOP PLATE WINDOW HEADER WINDOW UNIT 2x6 STUDS @ 16" O.C. 1/2" OSB SHEATHING STUCCO DOOR UNIT DOOR HEADER R-23 BLOWN FIBERGLASS 8" CONCRETE FOUNDATION SEAL COATING FOOTING TO MIN 30" BELOW GRADE - ON UNDISTURBED SOIL PERIMETER DRAIN 4" CONCRETE FLOOR W/ HYDRONIC HEAT TUBING 2" RIGID INSULTAION TREATED 2x6 SILL PLATE W/ ANCHOR BOLTS PER ENGINEER TIMBER TRUSS ONE 2x14 RAFTERS @ 24" O.C. W/ 3" CLOSED CELL FOAM AND BLOWN FIBERGLASS TO R-50 1/2" OSB SHEATHING W/ #30 FELT W/ 50 YEAR ASPHALT SHINGLES 6x BEAM 4x6 ANGLE BRACE 6x BEAM 4x6 ANGLE BRACE TIMBER STRINGERS EACH SIDE TIMBER TREADS METAL RAILING W/ CABLES NOTE: VERIFY STAIR DIMENSIONS IN FIELD SEE IRC 2015 SECTION R311.7 STAIRWAYS WIDTH - STAIRWAY SHALL BE NOT LESS THAN 36" WIDE - HANDRAILS SHALL NOT PROJECT MORE THAN 4-1/2" ON EITHER SIDE OF THE STAIRWAY AND THE CLEAR WIDTH OF THE STAIRWAY AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31-1/2" HEADROOM - MINIMUM HEADROOM REQUIRED 6'-8" MEASURED FROM SLOPE OF STAIR NOSING TO FINISHED SURFACE DIRECTLY ABOVE VERTICAL RISE - VERTICAL RISE SHALL NOT EXCEED 147" BETWEEN FLOORS AND LANDINGS RISERS - RISERS SHALL NOT EXCEED 7-3/4" AND SHALL NOT VARY MORE THAN 3/8" BETWEEN THE TALLEST AND THE SHORTEST RISER WITHIN A SET OF STAIRS TREADS - TREAD DEPTH SHALL NOT BE LESS THAN 10" AND THE WIDEST AND THE NARROWEST TREAD WITHIN A SET OF STAIRS SHALL NOT VARY MY MORE THAN 3/8" LANDINGS - THERE SHALL BE A LANDING AT THE TOP AND THE BOTTOM OF THE STAIR THAT MUST BE AT LEAST AS WIDE AS THE STAIR AND BE NO LESS THAN 36" IN THE DIRECTION OF TRAVEL HANDRAILS - A 1-1/2" GRIP SIZE HANDRAIL SHALL BE PROVIDED 34" TO 38" ABOVE THE LINE OF TREAD NOSING AND BE CONTINUOUS FOR THE ENTIRETY OF THE SECTION OF STAIR RAILINGS - RAILINGS OR GUARDS SHALL BE PROVIDED AT OPEN SIDE OF STAIR PER SECTION R312 THIS NOTE SHOWS ONLY THE GENERAL REQUIREMENTS FOR THIS SECTION - REFER TO IRC 2015 SECTION R311.7 FOR COMPLETE INFORMATION 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -8 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com Bas ement Plan U pper Floor Plan scale 1/2"=1'-0" Section Detail H scale 1/2"=1'-0" Section Detail F Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan 12 14 15'-7 1/2" 1' 10'-10" 7'-9" W11 W11 LVL RIDGE PER ENGINEER 2x12 RAFTERS @ 24" O.C. W/ CLOSED CELL FOAM TO R-50 StairStair Entry Porch 6 12 8'-10 1/8" 9'-11 1/8" 1'-6" 15'-8 7/8" 2'-1 3/4"11'-5 3/8"2'-1 3/4" 3'-4" Entry Porch MAIN FLOOR 10x12 BEAMS 10x10 POSTS CONCRETE TOP CAP STONE VENEER OVER 2x4 FRAMING POST ANCHOR T&G PINE CEILING 2x12 RAFTERS CONCRETE SLAB AND FOOTING PER ENGINEER scale 1/2"=1'-0" Section Detail J 12 14 5'-6 1/8" 5'-6" 24' 1 '-4 " W23 W20 Garage Bonus Room ATTIC TRUSSES 5/8" TYPE X GYP GARAGE DOOR HEADER GARAGE DOOR 4" CONCRETE FLOOR 2x6 STUDS @ 16" O.C. W/ R-23 INSULATION R-50 INSULATION R-30 BATTS 1-1/2" GYP-CRETE W/ HYDRONIC TUBING 5/8" GYP 1/2" GYP R-20 INSULATION 3/4" T&G DECKING 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -9 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com scale 1/2"=1'-0" Section Detail B Bas ement Plan U pper Floor Plan scale 1/2"=1'-0" Section Detail C scale 1/2"=1'-0" Section Detail G Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan 12 14 149 9/16" 10 1/4" 109 1/8" 5'-1 7/8" 5' 18' Top of Subfloor - 2nd Floor 9.95' Ridge 22.41' Rough Ceiling - 1st Floor 9.09' Top of Subfloor - 1st Floor 0.00' W32 W24 W30 W16 GLASS SHOWER WALL 1-1/2" GYPCRETE W/ HYDRONIC HEAT ATTIC TRUSSES W/ R-50 CLOSED CELL SPRAY FOAM R-20 INSULATION R-30 BATTS Master Bath Bath 3 12 14 5'-3 1/16" 2'-1 1/2" 2'-1 1/2"1'-6" 15'-10" W01 W05 D25 W18 W04 Master Bedroom 1-1/2" GYPCRETE W/ HYDRONIC HEAT ATTIC TRUSSES W/ R-50 CLOSED CELL SPRAY FOAM R-20 INSULATION R-30 BATTS Bedroom 3 10 12 10'-5" 18' W10 W26 W10 W25 TIMBER TRUSS TWO 8x RIDGE BEAM 14" RAFTERS R-50 INSULATION Dining Outdoor Kitchen/Fireplace 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -10 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com Bas ement Plan U pper Floor Plan scale 1/2"=1'-0" Section Detail E Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan 4 12 4 12 12 14 98 5/8" 10 1/4" 109 1/8" 9'-2 5/8" 8'-2 5/8" 13'-8" Top of Subfloor - 2nd Floor 9.95' Rough Ceiling - 2nd Floor 18.17' Rough Ceiling - 1st Floor 9.09' Top of Subfloor - 1st Floor 0.00' W13 W22 D28 D15 D22 W17 D23 Shower Bath 4 Bedroom 4 Bath 2 Bedroom 2 Mud Laundry Hall ENGINEERED TRUSSES 22x36 SKYLIGHT 9-1/2" JOISTS 9-1/2" JOISTS LVL BEAM LVL BEAM 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -1 1 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com scale 1/2"=1'-0" Section Detail D Bas ement Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan 12 14 14' 9'-2 5/8" 5'-4 3/4" 9'-1 1/8" 1 '-4 " D16 D34D14 W20 D36 22x36 Skylight 22x36 Skylight TRUSSES 2x6 STUDS @ 16" O.C. 1-1/2" GYP-CRETE DOOR SCHEDULE NUMBER LABEL ROOM NAME QTY SIZE WIDTH HEIGHT R/O DESCRIPTION HEADER COMMENTS AREA, ACTUAL (SQ FT) D01 2668 CLOSET/MASTER BATH 1 2668 L IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D02 18080 GARAGE 1 18080 216 "96 "218"X99"GARAGE-GARAGE DOOR CHD19 2X12X224" (2)144.0 D03 2068 PANTRY/KITCHEN 1 2068 L IN 24 "80 "26"X82 1/2"HINGED-GLASS PANEL 2X6X29" (2)13.33 D04 2068 CLOSET/CLOSET 1 2068 R 24 "80 "50"X82 1/2"POCKET-DOOR P01 2X6X53" (2)13.33 D06 2668 MASTER BATH/MASTER BDRM 1 2668 L IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D07 2668 PDR/HALL 1 2668 R IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D08 2668 BEDROOM 3/BATH 3 1 2668 L 30 "80 "62"X82 1/2"POCKET-DOOR P01 2X6X65" (2)16.67 D09 2668 BATH 5/BATH 5 1 2668 L IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D10 2668 BATH 5/HALL 1 2668 R IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D11 2868 BEDROOM 2/BATH 2 1 2868 L 32 "80 "66"X82 1/2"POCKET-DOOR P01 2X6X69" (2)17.78 D12 2868 BEDROOM 2/HALL 1 2868 L IN 32 "80 "34"X82 1/2"HINGED-DOOR P01 2X6X37" (2)17.78 D13 2868 BEDROOM 4/BATH 4 1 2868 R 32 "80 "66"X82 1/2"POCKET-DOOR P01 2X6X69" (2)17.78 D14 3068 GARAGE/UTILITY 1 3068 L EX 36 "80 "38"X83"EXT. HINGED-SLAB 2X6X41" (2)20.0 D15 3068 HALL/LAUNDRY 1 3068 L IN 36 "80 "38"X82 1/2"HINGED-DOOR P01 2X6X41" (2)20.0 D16 3068 GARAGE 1 3068 R EX 36 "80 "38"X83"EXT. HINGED-DOOR E21 2X6X41" (2)20.0 D17 3068 HALL/UNSPECIFIED 1 3068 L IN 36 "80 "38"X82 1/2"HINGED-DOOR P01 2X6X41" (2)20.0 D18 3068 BRIDGE/BEDROOM 3 1 3068 R IN 36 "80 "38"X82 1/2"HINGED-DOOR P01 2X6X41" (2)20.0 D19 3080 HALL/LIBRARY 1 3080 R IN 36 "96 "38"X98 1/2"HINGED-DOOR P01 2X6X41" (2)24.0 D20 4068 BEDROOM 4/UNSPECIFIED 1 4068 R IN 47 13/16 "80 "49 13/16"X82 1/2"SLIDER-PANEL 2X8X52 13/16" (2)26.56 D21 5068 MASTER BDRM 1 5068 R EX 60 "80 "62"X83"EXT. SLIDER-GLASS PANEL 2X8X65" (2)33.33 D22 5068 BEDROOM 2/UNSPECIFIED 1 5068 R IN 60 "80 "62"X82 1/2"SLIDER-PANEL 2X8X65" (2)33.33 D23 5068 BEDROOM 4/UNSPECIFIED 1 5068 R IN 60 "80 "62"X82 1/2"SLIDER-PANEL 2X8X65" (2)33.33 D24 5080 ENTRY/STAIR/PORCH 1 5080 L/R EX 59 1/2 "96 "61 1/2"X99"EXT. DOUBLE HINGED-DOOR PS04 2X8X64 1/2" (2)38.11 D25 6068 BEDROOM 3/DECK 1 6068 R EX 72 "80 "74"X83"EXT. SLIDER-GLASS PANEL 2X10X77" (2)40.0 D26 5068 CLOSET/BATH 3 1 5068 R IN 60 "80 "62"X82 1/2"SLIDER-PANEL 2X8X65" (2)33.33 D27 6080 DINING 1 6080 L EX 72 "96 "74"X99"EXT. SLIDER-GLASS PANEL 2X10X77" (2)48.0 D28 6080 DINING 1 6080 R EX 72 "96 "74"X99"EXT. SLIDER-GLASS PANEL 2X10X77" (2)48.0 D29 8080 BEDROOM 2 1 8080 L EX 96 "96 "98"X99"EXT. SLIDER-GLASS PANEL 2X12X101" (2)64.0 D30 9080 GARAGE 1 9080 108 "96 "110"X99"GARAGE-GARAGE DOOR CHD19 2X12X116" (2)72.0 D31 9080 LIVING 2 9080 L/R EX 108 "96 "110"X99"EXT. QUAD SLIDER-GLASS PANEL 2X12X113" (2)72.0 D32 2668 LINEN/UNSPECIFIED 1 2668 R IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D33 2668 UNSPECIFIED/MASTER BATH 1 2668 L IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D34 3068 GARAGE/HALL 1 3068 R EX 36 "80 "38"X83"EXT. HINGED-PANEL 2X6X41" (2)20.0 D35 2668 UNSPECIFIED/BEDROOM 4 1 2668 L IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 D36 2668 SHOWER ROOM/BATH 5 1 2668 R IN 30 "80 "32"X82 1/2"HINGED-DOOR P01 2X6X35" (2)16.67 TOTALS:1148.69 WINDOW SCHEDULE NUMBER LABEL ROOM NAME QTY SIZE WIDTH HEIGHT TOP TEMPERED EGRESS DESCRIPTION COMMENTS AREA, ACTUAL (SQ FT) W01 10460MU MASTER BDRM 1 10460 124 "72 "88"MULLED UNIT-HR 62.0 W02 4016FX BATH 4 1 4016FX 48 "18 "101"FIXED GLASS 6.0 W03 2033SC 1 2033SC 24 "39 "-9 5/8"SINGLE CASEMENT-HR 6.5 W04 2046SC BEDROOM 3/DECK 1 2046SC 24 "54 "66"YES SINGLE CASEMENT-HL 9.0 W05 2046SC BEDROOM 3/DECK 1 2046SC 24 "54 "66"YES SINGLE CASEMENT-HR 9.0 W06 2640SC BEDROOM 2 1 2640SC 30 "48 "88"SINGLE CASEMENT-HR 10.0 W07 7850MU BEDROOM 4 1 7850 92 "60 "88"MULLED UNIT-HR 38.33 W08 2640SC BEDROOM 2 1 2640SC 30 "48 "88"SINGLE CASEMENT-HL 10.0 W09 2670FX ENTRY/STAIR/PORCH 2 2670FX 30 "84 "85"YES FIXED GLASS 17.5 W10 3060FX DINING 2 3060FX 36 "72 "96"FIXED GLASS 18.0 W11 4660FX OPEN BELOW 2 4660FX 54 "72 "82"YES FIXED GLASS-AT 25.28 W12 5016FX BEDROOM 4 1 5016FX 60 "18 "88"FIXED GLASS 7.5 W13 5040DC HALL 1 5040DC 60 "48 "88"DOUBLE CASEMENT-LHL/RHR 20.0 W14 5040DC BRIDGE 1 5040DC 60 "48 "80"DOUBLE CASEMENT-LHL/RHR 20.0 W16 5052MU BATH 3 1 5052 60 "62 "100"MULLED UNIT-HR 23.87 W17 5650DC BEDROOM 3 1 5650DC 66 "60 "106 1/8"DOUBLE CASEMENT-LHL/RHR-AT 25.51 W18 60110FX BEDROOM 3/DECK 1 60110FX 72 "22 "106 9/16"FIXED GLASS-AT 8.77 W19 6040FX 1 6040FX 72 "48 "66 1/2"FIXED GLASS-AT 21.77 W20 6264MU BONUS ROOM 3 6264 74 "76 "102"MULLED UNIT-HR 36.91 W21 6433MU OPEN BELOW 1 6433 76 "39 "88"MULLED UNIT-HR 20.58 W22 71026MU CLOSET 1 71026 93 1/2 "30 "88"MULLED UNIT-HR FROSTED GLASS 19.48 W23 71026MU GARAGE 2 71026 94 "30 "107"MULLED UNIT-HR 19.58 W24 7140MU MASTER BATH 1 7140 85 "48 "88"MULLED UNIT-HR 28.33 W25 8050FX OPEN BELOW 1 8050FX 96 "60 "51"FIXED GLASS-AT 35.09 W26 8060FX DINING 1 8060FX 96 "72 "96"FIXED GLASS 48.0 W27 81046MU OPEN BELOW 1 81046 106 "54 "82"MULLED UNIT-HR 39.75 W28 90510MU OPEN BELOW 1 90510 108 "70 "82"MULLED UNIT-HR 52.5 W29 2640SC LAUNDRY 1 2640SC 30 "48 "88"SINGLE CASEMENT-HR 10.0 W30 2640SC MASTER BATH 1 2640SC 30 "48 "88"SINGLE CASEMENT-HL 10.0 W31 2640SC PDR 1 2640SC 30 "48 "88"SINGLE CASEMENT-HR 10.0 W32 2640SC UNSPECIFIED 1 2640SC 30 "48 "88"SINGLE CASEMENT-HR 10.0 W33 5040DC LIBRARY 1 5040DC 60 "48 "88"DOUBLE CASEMENT-LHL/RHR 20.0 TOTALS:853.43 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -1 2 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com Bas ement Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan scale 1/4"=1'-0" Main Floor Electrical Plan UPUP CO/SD CO/SD CO/SD SD SD TV TV TV TV TV TV GFCI GFCI GFCI R GFCI GFCI GFCI GFCI WP WP WP WP WP WP GFCI R R R R R R R RR RR R R R R R R R RRRR 4 44 4 4 4 3 3 3 3 3 3 3 3 3 3 3 4 3 4 3 3 4 3 3 3 33 3 3 3 3 3 3-WAY TO TOP OF STAIR 3-WAY TO TOP OF STAIR FAN/LIGHT FAN/LIGHT WP R 4 GFCI 3WP SD T TV DESCRIPTIONSYMBOL ELECTRICAL - DATA - AUDIO LEGEND Ceiling Fan Ventilation Fans: Ceiling Mounted, Wall Mounted Ceiling Mounted Light Fixtures, Recessed Can Light Wall Mounted Light Fixtures: Flush Mounted, Wall Sconce 240V Receptacle 110V Receptacles: Duplex, Weather Proof, GFCI Switches: Single Pole, Weather Proof, 3-Way, 4-Way Wall Jacks: TV/Cable Telephone Jack Thermostat Door Chime, Door Bell Button Smoke Detectors: Ceiling Mounted, Wall Mounted Smoke/CO Detectors: Ceiling Mounted, Wall MountedCO/SD ELECTRICAL, DATA, & AUDIO NOTES: HOME OWNER SHALL DO A WALK-THRU WITH RELEVANT INSTALLERS TO VERIFY THE EXACT LOCATION FOR OUTLETS, LIGHTS, SWITCHES, CABLE, DATA, PHONE, AUDIO, ETC. ELECTRICAL NOTES: 1.ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE G.F.I. ORG.F.I.C. PER NATIONAL ELECTRICAL CODE REQUIREMENTS. 2.PROVIDE ONE SMOKE DETECTOR IN EACH ROOM AND ONE IN EACH CORRIDOR ACCESSING BEDROOMS. CONNECT SMOKE DETECTORS TO HOUSE POWER AND INTER-CONNECT SMOKE DETECTORS SO THAT, WHEN ANY ONE IS TRIPPED, THEY ALL WILL SOUND. PROVIDE BATTERY BACKUP FOR ALL UNITS. 3.CIRCUITS SHALL BE VERIFIED WITH HOME OWNER PRIOR TO WIRE INSTALLATION. 4.FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED WITH HOME OWNER. 5.FIXTURES TO BE SELECTED BY HOME OWNER. 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -1 3 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com Bas ement Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan Roof Framing Plan scale 1/4"=1'-0" Upper Floor Electrical Plan WP R 4 GFCI 3WP SD T TV DESCRIPTIONSYMBOL ELECTRICAL - DATA - AUDIO LEGEND Ceiling Fan Ventilation Fans: Ceiling Mounted, Wall Mounted Ceiling Mounted Light Fixtures, Recessed Can Light Wall Mounted Light Fixtures: Flush Mounted, Wall Sconce 240V Receptacle 110V Receptacles: Duplex, Weather Proof, GFCI Switches: Single Pole, Weather Proof, 3-Way, 4-Way Wall Jacks: TV/Cable Telephone Jack Thermostat Door Chime, Door Bell Button Smoke Detectors: Ceiling Mounted, Wall Mounted Smoke/CO Detectors: Ceiling Mounted, Wall MountedCO/SD ELECTRICAL, DATA, & AUDIO NOTES: HOME OWNER SHALL DO A WALK-THRU WITH RELEVANT INSTALLERS TO VERIFY THE EXACT LOCATION FOR OUTLETS, LIGHTS, SWITCHES, CABLE, DATA, PHONE, AUDIO, ETC. ELECTRICAL NOTES: 1.ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE G.F.I. ORG.F.I.C. PER NATIONAL ELECTRICAL CODE REQUIREMENTS. 2.PROVIDE ONE SMOKE DETECTOR IN EACH ROOM AND ONE IN EACH CORRIDOR ACCESSING BEDROOMS. CONNECT SMOKE DETECTORS TO HOUSE POWER AND INTER-CONNECT SMOKE DETECTORS SO THAT, WHEN ANY ONE IS TRIPPED, THEY ALL WILL SOUND. PROVIDE BATTERY BACKUP FOR ALL UNITS. 3.CIRCUITS SHALL BE VERIFIED WITH HOME OWNER PRIOR TO WIRE INSTALLATION. 4.FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED WITH HOME OWNER. 5.FIXTURES TO BE SELECTED BY HOME OWNER. DNDN TV TV TV TV SD CO/SD CO/SD SD SD R R R R GFCI GFCI GFCI GFCI GFCI GFCI R R R R R R R R R R R R R R R R R R 3 3 44 4 3 3 3 3 R R WP FAN/LIGHT 3-WAY TO BOTTOM OF STAIR 3-WAY TO BOTTOM OF STAIR FAN/LIGHT FAN/LIGHT 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -1 4 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com Bas ement Plan U pper Floor Plan Second Floor Plan Firs t Floor Plan Floor Plan Firs t Floor Framing Plan Second Floor Fram ing Plan Roof Plan Main Floor Fram ing Plan U pper Floor Framing Plan Roof Framing Plan 6 x 66x6 12 14 4 12 9'-3 7/16"5'-8 1/16"5'-8 1/16"9'-3 7/16" 29'-11" 3'-1 1/8" 6'-7 7/16" 9'-0 11/16"5'-10 13/16"5'-10 13/16"9'-0 11/16" 6 x 8 8x14 6x10 6x10 6 x 8 8x14 6 x 1 0 6 x 1 0 CUT FROM 6x10 ANGLE BRACE 6x BEAM ANGLE BRACE 6x BEAM ANGLE BRACE 6x BEAM 6x66x6 6x6 10 12 8'-6 1/8"5 3/16" 2'-2 1/2"6'-9" 17'-11" 6'-10 1/16" 4'-11 11/16" 8x RIDGE BEAM 6 x 1 0 6x8 6x10 CUT FROM 6x12 scale 3/4"=1'-0" Tim ber Trus s Two scale 3/4"=1'-0" Tim ber Trus s One 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -1 5 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com scale 1/4"=1'-0" Roof Plan UPUP 6 : 12 6 : 12 4 : 12 4 : 12 ENTRY PORCH DNDN 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 12 14 : 1214 : 12 14 : 12 14 : 12 10 : 12 10 : 12 4 : 12 4 : 12 3/16/2019 Contractor Don & Nancy Zimmerman Project Address: 1505 Deer Path Ct Estes Park CO © 2019 A -1 6 Zimmerman Residence SHEET NUMBER Revision DATE Nathan Kinley 970-227-4865 nathan@kinleybuilt.com