Loading...
HomeMy WebLinkAboutPLANS SFD 1151 Saxon Ct 2022-02-04Reviewed by SAFEbuilt 02/04/2022 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 02/04/2022 This structure must comply with the requirements of the 2020 National Electrical Code PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION Ice barrier required from the lowest edges of all roof surfaces to a point not less than 24" inside the exterior wall line of the building. IRC R905.1.2 Rim joist shall have an air barrier on the interior between each joist. All architectural plans, engineered foundation plans, soils reports, truss drawings, energy code report or ResCheck must be onsite for inspections. ON-DEMAND WATER HEATERS ARE NOT PERMITTED FOR THIS PROJECT All Irrigation Sprinkler Taps Shall be Protected by an Approved Back Flow Device Sheet No. De s i g n e r ' s I n k 59 8 W . 4 8 t h S t r e e t , L o v e l a n d , C o . Ph o n e : ( 9 7 0 ) 2 1 3 - 7 4 3 1 De s i g n a n d D r a f t i n g s e r v i c e s 11 5 1 S a x o n C o u r t Lo t 2 1 , B o n n i e B r a e S u b d . St o r m M o u n t a i n V e n t u r e s Es t e s P a r k , C o l o r a d o Date: Nov. 1, 2021 CM S P l a n n i n g & D e v e l o p e m e n t Ge n e r a l C o n t r a c t o r P. O . B o x 4 1 6 Es t e s P a r k , C o . 8 0 5 1 7 Ph . 9 7 0 - 2 3 1 - 6 2 0 0 STRUCTURAL 1/28/2022 PROVIDE CRAWLSPACE SPECS ON SITE FOR THE INSPECTOR Reviewed by SAFEbuilt 02/04/2022 Sheet No. De s i g n e r ' s I n k 59 8 W . 4 8 t h S t r e e t , L o v e l a n d , C o . Ph o n e : ( 9 7 0 ) 2 1 3 - 7 4 3 1 De s i g n a n d D r a f t i n g s e r v i c e s Date: Nov. 1, 2021 CM S P l a n n i n g & D e v e l o p e m e n t Ge n e r a l C o n t r a c t o r P. O . B o x 4 1 6 Es t e s P a r k , C o . 8 0 5 1 7 Ph . 9 7 0 - 2 3 1 - 6 2 0 0 11 5 1 S a x o n C o u r t Lo t 2 1 , B o n n i e B r a e S u b d . St o r m M o u n t a i n V e n t u r e s Es t e s P a r k , C o l o r a d o Typical Exterior Light Fixture No Scale Reviewed by SAFEbuilt 02/04/2022 Sheet No. De s i g n e r ' s I n k 59 8 W . 4 8 t h S t r e e t , L o v e l a n d , C o . Ph o n e : ( 9 7 0 ) 2 1 3 - 7 4 3 1 De s i g n a n d D r a f t i n g s e r v i c e s Date: Nov. 1, 2021 CM S P l a n n i n g & D e v e l o p e m e n t Ge n e r a l C o n t r a c t o r P. O . B o x 4 1 6 Es t e s P a r k , C o . 8 0 5 1 7 Ph . 9 7 0 - 2 3 1 - 6 2 0 0 11 5 1 S a x o n C o u r t Lo t 2 1 , B o n n i e B r a e S u b d . St o r m M o u n t a i n V e n t u r e s Es t e s P a r k , C o l o r a d o STRUCTURAL 1/28/2022 Reviewed by SAFEbuilt 02/04/2022 1/28/2022 Reviewed by SAFEbuilt 02/04/2022 Lot 21 Bonnie Brae Subdivision HVAC Load Calculations for CMS Planning & Development P.O. Box 416 Estes Park CO Prepared By: Rex Allen Air City Heating And A/C LLC. Tuesday, January 4, 2022 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. BASEBOARD HEATING PROPOSED SEE COMMUNITYCORE FOR THE BASEBOARD SERIAL NUMBERS Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 2 Project Report General Project Information Project Title:Lot 21 Bonnie Brae Subdivision Designed By:Designer's Ink Project Date:Tuesday, January 4, 2022 Project Comment:Home is all Electric Heating using Electric Baseboard units (per room). Client Name:CMS Planning & Development Client Address:P.O. Box 416 Client City:Estes Park CO Company Name:Air City Heating And A/C LLC. Company Representative:Rex Allen Design Data Reference City:Estes Park, Colorado Building Orientation:Front door faces South Daily Temperature Range:High Latitude:40 Degrees Elevation:4935 ft. Altitude Factor:0.834 Elevation Heating Adj. Factor:0.760 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:1 0.21 n/a n/a 72 n/a Summer:89 63 25%50%75 -16 Check Figures Total Building Supply CFM:232 CFM Per Square ft.:0.188 Square ft. of Room Area:1,231 Square ft. Per Ton:3,411 Volume (ft³):10,738 Building Loads Total Heating Required Including Ventilation Air:19,987 Btuh 19.987 MBH (Based On 0.760 Derating) Total Sensible Gain:4,515 Btuh 100 % Total Latent Gain:-184 Btuh 0 % Total Cooling Required Including Ventilation Air:4,515 Btuh 0.38 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 3 Miscellaneous Report System 1 Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:1 0.21 80%n/a 72 n/a Summer:89 63 25%50%75 -15.99 Duct Sizing Inputs Main Trunk Runouts Calculate:No No Use Schedule:No No Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:0 ft./min 0 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:0 in.0 in. Maximum Height:0 in.0 in. Outside Air Data Winter Summer Infiltration Specified:0.160 AC/hr 0.080 AC/hr 29 CFM 14 CFM Infiltration Actual:0.113 AC/hr 0.000 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 10,738 X 10,738 1,212 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:20 CFM 0 CFM Total Building Ventilation:20 CFM 20 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 12.85 = (1.10 X 0.834 X 14.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: -9.07 = (0.68 X 0.834 X -15.99 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 65.14 = (1.10 X 0.834 X 71.00 Winter Temp. Difference) Winter Infiltration Specified:0.160 AC/hr (29 CFM), Construction: Tight Summer Infiltration Specified:0.080 AC/hr (14 CFM), Construction: Tight C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 4 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 0.38 3,411 1,231 4,515 -184 4,515 15,190 216 232 232 System 1 0.38 3,411 1,231 4,515 -184 4,515 15,190 216 232 232 Ventilation 261 -184 261 1,322 Zone 1 1,231 4,254 0 4,254 13,868 216 232 232 1-Master Suite 162 386 0 386 1,941 30 21 21 2-Master Bath /closet 122 220 0 220 1,422 22 12 12 3-Dinning / Greatroom 236 1,608 0 1,608 3,686 57 88 88 4-Kitchen 208 181 0 181 962 15 10 10 5-Bedroom 3 126 549 0 549 1,048 16 30 30 6-Laundry Room / Hall 64 81 0 81 760 12 4 4 7-Bath 3 / Hall 108 239 0 239 646 10 13 13 8-Foyer 49 229 0 229 1,247 19 12 12 9-Bedroom 2 156 761 0 761 2,156 34 41 41 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-6-d: Glazing-Double pane low-e (e = 0.20 or less), high performance, sliding glass door, e=0.05 on surface 2, any frame, U-value 0.31, SHGC 0.31 20 440 0 206 206 4A-6-d: Glazing-Double pane low-e (e = 0.20 or less), high performance, sliding glass door, e=0.05 on surface 2, any frame, U-value 0.33, SHGC 0.33 109 2,554 0 2,573 2,573 11D: Door-Wood - Solid Core, U-value 0.39 21 581 0 164 164 12F-0bw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, brick finish, wood studs, U-value 0.065 1199 5,534 0 359 359 16DR-44: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic with Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel Membrane, R-44 insulation, U-value 0.022 1231 1,924 0 651 651 19D-0sp: Floor-Over enclosed crawl space, R-19 insulation on exposed walls, sealed crawl space, passive, no floor insulation, carpet or hardwood, U- value 0.368 1231 1,520 0 301 301 Subtotals for structure:12,553 0 4,254 4,254 People:0 0 0 0 Equipment:0 0 0 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 20, Summer CFM: 0 1,315 0 0 0 Ventilation: Winter CFM: 20, Summer CFM: 20 1,322 -184 261 77 Total Building Load Totals:15,190 -184 4,515 4,331 Check Figures Total Building Supply CFM:232 CFM Per Square ft.:0.188 Square ft. of Room Area:1,231 Square ft. Per Ton:3,411 Volume (ft³):10,738 Building Loads Total Heating Required Including Ventilation Air:19,987 Btuh 19.987 MBH (Based On 0.760 Derating) Total Sensible Gain:4,515 Btuh 100 % Total Latent Gain:-184 Btuh 0 % Total Cooling Required Including Ventilation Air:4,515 Btuh 0.38 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 6 Building Pie Chart Building Loss 15,190 Btuh Floor 10% Roof 13% Wall 36% Glass 20% Door 4% Infiltration 9% Ventilation 9% Building Gain 4,331 Btuh Floor 7% Roof 15% Wall 8% Glass 64% Door 4% Ventilation 2% C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 7 Detailed Room Loads - Room 1 - Master Suite (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:12.0 ft.System Number:1 Room Width:13.5 ft.Zone Number:1 Area:162.0 sq.ft.Supply Air:21 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.0 AC/hr Volume:1,296 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:3 CFM Runout Air:0 CFM Percent of Supply.:14 % Actual Summer Vent.:2 CFM Percent of Supply:9 % Actual Winter Infil.:3 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0bw 13.5 X 8 88 0.065 4.6 406 0.3 0 26 S -Wall-12F-0bw 12 X 8 96 0.065 4.6 443 0.3 0 29 N -Gls-4A-6-d shgc-0.31 100%S (2)8 0.310 22.0 176 10.3 0 82 N -Gls-4A-6-d shgc-0.31 100%S 12 0.310 22.0 264 10.3 0 124 UP-Ceil-16DR-44 12 X 13.5 162 0.022 1.6 253 0.5 0 86 Floor-19D-0sp 13.5 X 12 162 0.368 1.2 200 0.2 0 39 Subtotals for Structure:1,742 0 386 Infil.: Win.: 3.1, Sum.: 0.0 204 0.975 199 0.000 0 0 Room Totals:1,941 0 386 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 8 Detailed Room Loads - Room 2 - Master Bath /closet (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:9.0 ft.System Number:1 Room Width:13.5 ft.Zone Number:1 Area:121.5 sq.ft.Supply Air:12 CFM Ceiling Height:8.0 ft.Supply Air Changes:0.7 AC/hr Volume:972 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:2 CFM Runout Air:0 CFM Percent of Supply.:17 % Actual Summer Vent.:1 CFM Percent of Supply:9 % Actual Winter Infil.:3 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0bw 13.5 X 8 104 0.065 4.6 480 0.3 0 31 W -Wall-12F-0bw 9 X 8 72 0.065 4.6 332 0.3 0 22 S -Gls-4A-6-d shgc-0.33 0%S 4 0.330 23.4 94 18.3 0 73 UP-Ceil-16DR-44 9 X 13.5 121.5 0.022 1.6 190 0.5 0 64 Floor-19D-0sp 13.5 X 9 121.5 0.368 1.2 150 0.2 0 30 Subtotals for Structure:1,246 0 220 Infil.: Win.: 2.7, Sum.: 0.0 180 0.978 176 0.000 0 0 Room Totals:1,422 0 220 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 9 Detailed Room Loads - Room 3 - Dinning / Greatroom (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:22.5 ft.System Number:1 Room Width:10.5 ft.Zone Number:1 Area:236.3 sq.ft.Supply Air:88 CFM Ceiling Height:10.0 ft.Supply Air Changes:2.2 AC/hr Volume:2,363 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:5 CFM Runout Air:0 CFM Percent of Supply.:6 % Actual Summer Vent.:8 CFM Percent of Supply:9 % Actual Winter Infil.:5 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0bw 22.5 X 10 180 0.065 4.6 831 0.3 0 54 E -Wall-12F-0bw 10.5 X 8 60 0.065 4.6 277 0.3 0 18 N -Gls-4A-6-d shgc-0.33 100%S (2)24 0.330 23.4 562 11.0 0 264 E -Gls-4A-6-d shgc-0.33 0%S (2)24 0.330 23.4 562 35.8 0 858 N -Gls-4A-6-d shgc-0.33 100%S 21 0.330 23.4 492 11.0 0 231 UP-Ceil-16DR-44 22.5 X 10.5 236.2 0.022 1.6 369 0.5 0 125 Floor-19D-0sp 10.5 X 22.5 236.2 0.368 1.2 292 0.2 0 58 Subtotals for Structure:3,385 0 1,608 Infil.: Win.: 4.6, Sum.: 0.0 309 0.974 301 0.000 0 0 Room Totals:3,686 0 1,608 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 10 Detailed Room Loads - Room 4 - Kitchen (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:24.5 ft.System Number:1 Room Width:8.5 ft.Zone Number:1 Area:208.3 sq.ft.Supply Air:10 CFM Ceiling Height:10.0 ft.Supply Air Changes:0.3 AC/hr Volume:2,083 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:1 CFM Runout Air:0 CFM Percent of Supply.:14 % Actual Summer Vent.:1 CFM Percent of Supply:9 % Actual Winter Infil.:1 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0bw 8.5 X 8 68 0.065 4.6 314 0.3 0 20 UP-Ceil-16DR-44 24.5 X 8.5 208.2 0.022 1.6 325 0.5 0 110 Floor-19D-0sp 8.5 X 24.5 208.2 0.368 1.2 257 0.2 0 51 Subtotals for Structure:896 0 181 Infil.: Win.: 1.0, Sum.: 0.0 68 0.971 66 0.000 0 0 Room Totals:962 0 181 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 11 Detailed Room Loads - Room 5 - Bedroom 3 (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:12.0 ft.System Number:1 Room Width:10.5 ft.Zone Number:1 Area:126.0 sq.ft.Supply Air:30 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.8 AC/hr Volume:1,008 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:2 CFM Runout Air:0 CFM Percent of Supply.:5 % Actual Summer Vent.:3 CFM Percent of Supply:9 % Actual Winter Infil.:1 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0bw 10.5 X 8 72 0.065 4.6 332 0.3 0 22 E -Gls-4A-6-d shgc-0.33 0%S 12 0.330 23.4 281 35.8 0 429 UP-Ceil-16DR-44 12 X 10.5 126 0.022 1.6 197 0.5 0 67 Floor-19D-0sp 10.5 X 12 126 0.368 1.2 156 0.2 0 31 Subtotals for Structure:966 0 549 Infil.: Win.: 1.3, Sum.: 0.0 84 0.976 82 0.000 0 0 Room Totals:1,048 0 549 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 12 Detailed Room Loads - Room 6 - Laundry Room / Hall (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:8.0 ft.System Number:1 Room Width:8.0 ft.Zone Number:1 Area:64.0 sq.ft.Supply Air:4 CFM Ceiling Height:8.0 ft.Supply Air Changes:0.5 AC/hr Volume:512 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:1 CFM Runout Air:0 CFM Percent of Supply.:25 % Actual Summer Vent.:0 CFM Percent of Supply:9 % Actual Winter Infil.:2 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain W -Wall-12F-0bw 13 X 8 104 0.065 4.6 480 0.3 0 31 UP-Ceil-16DR-44 8 X 8 64 0.022 1.6 100 0.5 0 34 Floor-19D-0sp 8 X 8 64 0.368 1.2 79 0.2 0 16 Subtotals for Structure:659 0 81 Infil.: Win.: 1.6, Sum.: 0.0 104 0.971 101 0.000 0 0 Room Totals:760 0 81 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 13 Detailed Room Loads - Room 7 - Bath 3 / Hall (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:6.0 ft.System Number:1 Room Width:18.0 ft.Zone Number:1 Area:108.0 sq.ft.Supply Air:13 CFM Ceiling Height:8.0 ft.Supply Air Changes:0.9 AC/hr Volume:864 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:1 CFM Runout Air:0 CFM Percent of Supply.:7 % Actual Summer Vent.:1 CFM Percent of Supply:9 % Actual Winter Infil.:1 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0bw 6 X 8 44 0.065 4.6 203 0.3 0 13 E -Gls-4A-6-d shgc-0.33 0%S 4 0.330 23.4 94 35.8 0 143 UP-Ceil-16DR-44 6 X 18 108 0.022 1.6 169 0.5 0 57 Floor-19D-0sp 18 X 6 108 0.368 1.2 133 0.2 0 26 Subtotals for Structure:599 0 239 Infil.: Win.: 0.7, Sum.: 0.0 48 0.979 47 0.000 0 0 Room Totals:646 0 239 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 14 Detailed Room Loads - Room 8 - Foyer (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:7.0 ft.System Number:1 Room Width:7.0 ft.Zone Number:1 Area:49.0 sq.ft.Supply Air:12 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.9 AC/hr Volume:392 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:2 CFM Runout Air:0 CFM Percent of Supply.:15 % Actual Summer Vent.:1 CFM Percent of Supply:9 % Actual Winter Infil.:2 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain W -Wall-12F-0bw 7 X 8 56 0.065 4.6 258 0.3 0 17 S -Wall-12F-0bw 7 X 8 35 0.065 4.6 162 0.3 0 10 S -Door-11D 3 X 7 21 0.390 27.7 581 7.8 0 164 UP-Ceil-16DR-44 7 X 7 49 0.022 1.6 77 0.5 0 26 Floor-19D-0sp 7 X 7 49 0.368 1.2 60 0.2 0 12 Subtotals for Structure:1,138 0 229 Infil.: Win.: 1.7, Sum.: 0.0 112 0.973 109 0.000 0 0 Room Totals:1,247 0 229 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 15 Detailed Room Loads - Room 9 - Bedroom 2 (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:12.0 ft.System Number:1 Room Width:13.0 ft.Zone Number:1 Area:156.0 sq.ft.Supply Air:41 CFM Ceiling Height:8.0 ft.Supply Air Changes:2.0 AC/hr Volume:1,248 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:3 CFM Runout Air:0 CFM Percent of Supply.:8 % Actual Summer Vent.:4 CFM Percent of Supply:9 % Actual Winter Infil.:4 CFM Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0bw 13 X 8 92 0.065 4.6 425 0.3 0 28 S -Wall-12F-0bw 12 X 8 88 0.065 4.6 406 0.3 0 26 N -Wall-12F-0bw 5 X 8 40 0.065 4.6 185 0.3 0 12 S -Gls-4A-6-d shgc-0.33 0%S (2)8 0.330 23.4 188 18.3 0 146 E -Gls-4A-6-d shgc-0.33 0%S 12 0.330 23.4 281 35.8 0 429 UP-Ceil-16DR-44 12 X 13 156 0.022 1.6 244 0.5 0 82 Floor-19D-0sp 13 X 12 156 0.368 1.2 193 0.2 0 38 Subtotals for Structure:1,922 0 761 Infil.: Win.: 3.6, Sum.: 0.0 240 0.975 234 0.000 0 0 Room Totals:2,156 0 761 C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision Loveland, CO 80538 Page 16 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Master Suite 162 1,941 30 1-0 0 386 0 21 21 2 Master Bath /closet 122 1,422 22 1-0 0 220 0 12 12 3 Dinning / Greatroom 236 3,686 57 1-0 0 1,608 0 88 88 4 Kitchen 208 962 15 1-0 0 181 0 10 10 5 Bedroom 3 126 1,048 16 1-0 0 549 0 30 30 6 Laundry Room / Hall 64 760 12 1-0 0 81 0 4 4 7 Bath 3 / Hall 108 646 10 1-0 0 239 0 13 13 8 Foyer 49 1,247 19 1-0 0 229 0 12 12 9 Bedroom 2 156 2,156 34 1-0 0 761 0 41 41 Ventilation 1,322 261 -184 System 1 total 1,231 15,190 216 4,515 -184 232 232 Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:0.38 104% / -4%4,515 -184 4,515 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency:0 AFUE 0 SEER Sound:0 0 Capacity:0 Btuh 0 Btuh Sensible Capacity:n/a 0 Btuh Latent Capacity:n/a 0 Btuh C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM Reviewed by SAFEbuilt 02/04/2022