HomeMy WebLinkAboutPLANS SFD 1151 Saxon Ct 2022-02-04Reviewed by
SAFEbuilt
02/04/2022
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
02/04/2022
This structure must comply
with the requirements of the
2020 National Electrical Code
PRINT PLANS IN COLOR AND HAVE FOR
INSPECTOR AT TIME OF INSPECTION
Ice barrier required from the lowest edges
of all roof surfaces to a point not less than
24" inside the exterior wall line of the
building. IRC R905.1.2
Rim joist shall have an air
barrier on the interior
between each joist.
All architectural plans,
engineered foundation
plans, soils reports,
truss drawings, energy
code report or
ResCheck must be
onsite for inspections.
ON-DEMAND WATER
HEATERS ARE NOT
PERMITTED FOR
THIS PROJECT
All Irrigation Sprinkler Taps
Shall be Protected by an
Approved Back Flow Device
Sheet No.
De
s
i
g
n
e
r
'
s
I
n
k
59
8
W
.
4
8
t
h
S
t
r
e
e
t
,
L
o
v
e
l
a
n
d
,
C
o
.
Ph
o
n
e
:
(
9
7
0
)
2
1
3
-
7
4
3
1
De
s
i
g
n
a
n
d
D
r
a
f
t
i
n
g
s
e
r
v
i
c
e
s
11
5
1
S
a
x
o
n
C
o
u
r
t
Lo
t
2
1
,
B
o
n
n
i
e
B
r
a
e
S
u
b
d
.
St
o
r
m
M
o
u
n
t
a
i
n
V
e
n
t
u
r
e
s
Es
t
e
s
P
a
r
k
,
C
o
l
o
r
a
d
o
Date: Nov. 1, 2021
CM
S
P
l
a
n
n
i
n
g
&
D
e
v
e
l
o
p
e
m
e
n
t
Ge
n
e
r
a
l
C
o
n
t
r
a
c
t
o
r
P.
O
.
B
o
x
4
1
6
Es
t
e
s
P
a
r
k
,
C
o
.
8
0
5
1
7
Ph
.
9
7
0
-
2
3
1
-
6
2
0
0
STRUCTURAL
1/28/2022
PROVIDE CRAWLSPACE
SPECS ON SITE FOR
THE INSPECTOR
Reviewed by
SAFEbuilt
02/04/2022
Sheet No.
De
s
i
g
n
e
r
'
s
I
n
k
59
8
W
.
4
8
t
h
S
t
r
e
e
t
,
L
o
v
e
l
a
n
d
,
C
o
.
Ph
o
n
e
:
(
9
7
0
)
2
1
3
-
7
4
3
1
De
s
i
g
n
a
n
d
D
r
a
f
t
i
n
g
s
e
r
v
i
c
e
s
Date: Nov. 1, 2021
CM
S
P
l
a
n
n
i
n
g
&
D
e
v
e
l
o
p
e
m
e
n
t
Ge
n
e
r
a
l
C
o
n
t
r
a
c
t
o
r
P.
O
.
B
o
x
4
1
6
Es
t
e
s
P
a
r
k
,
C
o
.
8
0
5
1
7
Ph
.
9
7
0
-
2
3
1
-
6
2
0
0
11
5
1
S
a
x
o
n
C
o
u
r
t
Lo
t
2
1
,
B
o
n
n
i
e
B
r
a
e
S
u
b
d
.
St
o
r
m
M
o
u
n
t
a
i
n
V
e
n
t
u
r
e
s
Es
t
e
s
P
a
r
k
,
C
o
l
o
r
a
d
o
Typical Exterior Light Fixture
No Scale
Reviewed by
SAFEbuilt
02/04/2022
Sheet No.
De
s
i
g
n
e
r
'
s
I
n
k
59
8
W
.
4
8
t
h
S
t
r
e
e
t
,
L
o
v
e
l
a
n
d
,
C
o
.
Ph
o
n
e
:
(
9
7
0
)
2
1
3
-
7
4
3
1
De
s
i
g
n
a
n
d
D
r
a
f
t
i
n
g
s
e
r
v
i
c
e
s
Date: Nov. 1, 2021
CM
S
P
l
a
n
n
i
n
g
&
D
e
v
e
l
o
p
e
m
e
n
t
Ge
n
e
r
a
l
C
o
n
t
r
a
c
t
o
r
P.
O
.
B
o
x
4
1
6
Es
t
e
s
P
a
r
k
,
C
o
.
8
0
5
1
7
Ph
.
9
7
0
-
2
3
1
-
6
2
0
0
11
5
1
S
a
x
o
n
C
o
u
r
t
Lo
t
2
1
,
B
o
n
n
i
e
B
r
a
e
S
u
b
d
.
St
o
r
m
M
o
u
n
t
a
i
n
V
e
n
t
u
r
e
s
Es
t
e
s
P
a
r
k
,
C
o
l
o
r
a
d
o
STRUCTURAL
1/28/2022
Reviewed by
SAFEbuilt
02/04/2022
1/28/2022
Reviewed by
SAFEbuilt
02/04/2022
Lot 21 Bonnie Brae Subdivision
HVAC Load Calculations
for
CMS Planning & Development
P.O. Box 416
Estes Park CO
Prepared By:
Rex Allen
Air City Heating And A/C LLC.
Tuesday, January 4, 2022
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
BASEBOARD HEATING
PROPOSED
SEE COMMUNITYCORE FOR
THE BASEBOARD SERIAL
NUMBERS
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 2
Project Report
General Project Information
Project Title:Lot 21 Bonnie Brae Subdivision
Designed By:Designer's Ink
Project Date:Tuesday, January 4, 2022
Project Comment:Home is all Electric Heating using Electric Baseboard units (per room).
Client Name:CMS Planning & Development
Client Address:P.O. Box 416
Client City:Estes Park CO
Company Name:Air City Heating And A/C LLC.
Company Representative:Rex Allen
Design Data
Reference City:Estes Park, Colorado
Building Orientation:Front door faces South
Daily Temperature Range:High
Latitude:40 Degrees
Elevation:4935 ft.
Altitude Factor:0.834
Elevation Heating Adj. Factor:0.760
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:1 0.21 n/a n/a 72 n/a
Summer:89 63 25%50%75 -16
Check Figures
Total Building Supply CFM:232 CFM Per Square ft.:0.188
Square ft. of Room Area:1,231 Square ft. Per Ton:3,411
Volume (ft³):10,738
Building Loads
Total Heating Required Including Ventilation Air:19,987 Btuh 19.987 MBH (Based On 0.760 Derating)
Total Sensible Gain:4,515 Btuh 100 %
Total Latent Gain:-184 Btuh 0 %
Total Cooling Required Including Ventilation Air:4,515 Btuh 0.38 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 3
Miscellaneous Report
System 1
Input Data
Outdoor
Dry Bulb
Outdoor
Wet Bulb
Outdoor
Rel.Hum
Indoor
Rel.Hum
Indoor
Dry Bulb
Grains
Difference
Winter:1 0.21 80%n/a 72 n/a
Summer:89 63 25%50%75 -15.99
Duct Sizing Inputs
Main Trunk Runouts
Calculate:No No
Use Schedule:No No
Roughness Factor:0.00300 0.01000
Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft.
Minimum Velocity:0 ft./min 0 ft./min
Maximum Velocity:900 ft./min 750 ft./min
Minimum Height:0 in.0 in.
Maximum Height:0 in.0 in.
Outside Air Data
Winter Summer
Infiltration Specified:0.160 AC/hr 0.080 AC/hr
29 CFM 14 CFM
Infiltration Actual:0.113 AC/hr 0.000 AC/hr
Above Grade Volume:Cu.ft.Cu.ft.X 10,738 X 10,738
1,212 Cu.ft./hr 0 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration:20 CFM 0 CFM
Total Building Ventilation:20 CFM 20 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 12.85 = (1.10 X 0.834 X 14.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: -9.07 = (0.68 X 0.834 X -15.99 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 65.14 = (1.10 X 0.834 X 71.00 Winter Temp. Difference)
Winter Infiltration Specified:0.160 AC/hr (29 CFM), Construction: Tight
Summer Infiltration Specified:0.080 AC/hr (14 CFM), Construction: Tight
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 4
Load Preview Report
Scope
Net
Ton
ft.²
/Ton Area
Sen
Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
Clg
CFM
Sys
Act
CFM
Duct
Size
Building 0.38 3,411 1,231 4,515 -184 4,515 15,190 216 232 232
System 1 0.38 3,411 1,231 4,515 -184 4,515 15,190 216 232 232
Ventilation 261 -184 261 1,322
Zone 1 1,231 4,254 0 4,254 13,868 216 232 232
1-Master Suite 162 386 0 386 1,941 30 21 21
2-Master Bath /closet 122 220 0 220 1,422 22 12 12
3-Dinning / Greatroom 236 1,608 0 1,608 3,686 57 88 88
4-Kitchen 208 181 0 181 962 15 10 10
5-Bedroom 3 126 549 0 549 1,048 16 30 30
6-Laundry Room / Hall 64 81 0 81 760 12 4 4
7-Bath 3 / Hall 108 239 0 239 646 10 13 13
8-Foyer 49 229 0 229 1,247 19 12 12
9-Bedroom 2 156 761 0 761 2,156 34 41 41
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 5
Total Building Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
4A-6-d: Glazing-Double pane low-e (e = 0.20 or less),
high performance, sliding glass door, e=0.05 on
surface 2, any frame, U-value 0.31, SHGC 0.31
20 440 0 206 206
4A-6-d: Glazing-Double pane low-e (e = 0.20 or less),
high performance, sliding glass door, e=0.05 on
surface 2, any frame, U-value 0.33, SHGC 0.33
109 2,554 0 2,573 2,573
11D: Door-Wood - Solid Core, U-value 0.39 21 581 0 164 164
12F-0bw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, brick finish, wood studs,
U-value 0.065
1199 5,534 0 359 359
16DR-44: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic with Radiant Barrier, White or
Light Color Shingles, Any Wood Shake, Light Metal,
Tar and Gravel Membrane, R-44 insulation, U-value
0.022
1231 1,924 0 651 651
19D-0sp: Floor-Over enclosed crawl space, R-19
insulation on exposed walls, sealed crawl space,
passive, no floor insulation, carpet or hardwood, U-
value 0.368
1231 1,520 0 301 301
Subtotals for structure:12,553 0 4,254 4,254
People:0 0 0 0
Equipment:0 0 0
Lighting:0 0 0
Ductwork:0 0 0 0
Infiltration: Winter CFM: 20, Summer CFM: 0 1,315 0 0 0
Ventilation: Winter CFM: 20, Summer CFM: 20 1,322 -184 261 77
Total Building Load Totals:15,190 -184 4,515 4,331
Check Figures
Total Building Supply CFM:232 CFM Per Square ft.:0.188
Square ft. of Room Area:1,231 Square ft. Per Ton:3,411
Volume (ft³):10,738
Building Loads
Total Heating Required Including Ventilation Air:19,987 Btuh 19.987 MBH (Based On 0.760 Derating)
Total Sensible Gain:4,515 Btuh 100 %
Total Latent Gain:-184 Btuh 0 %
Total Cooling Required Including Ventilation Air:4,515 Btuh 0.38 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 6
Building Pie Chart
Building
Loss
15,190
Btuh
Floor 10%
Roof 13%
Wall 36%
Glass 20%
Door 4%
Infiltration 9%
Ventilation 9%
Building
Gain
4,331
Btuh
Floor 7%
Roof 15%
Wall 8%
Glass 64%
Door 4%
Ventilation 2%
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 7
Detailed Room Loads - Room 1 - Master Suite (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:12.0 ft.System Number:1
Room Width:13.5 ft.Zone Number:1
Area:162.0 sq.ft.Supply Air:21 CFM
Ceiling Height:8.0 ft.Supply Air Changes:1.0 AC/hr
Volume:1,296 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:3 CFM
Runout Air:0 CFM Percent of Supply.:14 %
Actual Summer Vent.:2 CFM
Percent of Supply:9 %
Actual Winter Infil.:3 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
N -Wall-12F-0bw 13.5 X 8 88 0.065 4.6 406 0.3 0 26
S -Wall-12F-0bw 12 X 8 96 0.065 4.6 443 0.3 0 29
N -Gls-4A-6-d shgc-0.31 100%S (2)8 0.310 22.0 176 10.3 0 82
N -Gls-4A-6-d shgc-0.31 100%S 12 0.310 22.0 264 10.3 0 124
UP-Ceil-16DR-44 12 X 13.5 162 0.022 1.6 253 0.5 0 86
Floor-19D-0sp 13.5 X 12 162 0.368 1.2 200 0.2 0 39
Subtotals for Structure:1,742 0 386
Infil.: Win.: 3.1, Sum.: 0.0 204 0.975 199 0.000 0 0
Room Totals:1,941 0 386
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 8
Detailed Room Loads - Room 2 - Master Bath /closet (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:9.0 ft.System Number:1
Room Width:13.5 ft.Zone Number:1
Area:121.5 sq.ft.Supply Air:12 CFM
Ceiling Height:8.0 ft.Supply Air Changes:0.7 AC/hr
Volume:972 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:2 CFM
Runout Air:0 CFM Percent of Supply.:17 %
Actual Summer Vent.:1 CFM
Percent of Supply:9 %
Actual Winter Infil.:3 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
S -Wall-12F-0bw 13.5 X 8 104 0.065 4.6 480 0.3 0 31
W -Wall-12F-0bw 9 X 8 72 0.065 4.6 332 0.3 0 22
S -Gls-4A-6-d shgc-0.33 0%S 4 0.330 23.4 94 18.3 0 73
UP-Ceil-16DR-44 9 X 13.5 121.5 0.022 1.6 190 0.5 0 64
Floor-19D-0sp 13.5 X 9 121.5 0.368 1.2 150 0.2 0 30
Subtotals for Structure:1,246 0 220
Infil.: Win.: 2.7, Sum.: 0.0 180 0.978 176 0.000 0 0
Room Totals:1,422 0 220
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 9
Detailed Room Loads - Room 3 - Dinning / Greatroom (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:22.5 ft.System Number:1
Room Width:10.5 ft.Zone Number:1
Area:236.3 sq.ft.Supply Air:88 CFM
Ceiling Height:10.0 ft.Supply Air Changes:2.2 AC/hr
Volume:2,363 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:5 CFM
Runout Air:0 CFM Percent of Supply.:6 %
Actual Summer Vent.:8 CFM
Percent of Supply:9 %
Actual Winter Infil.:5 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
N -Wall-12F-0bw 22.5 X 10 180 0.065 4.6 831 0.3 0 54
E -Wall-12F-0bw 10.5 X 8 60 0.065 4.6 277 0.3 0 18
N -Gls-4A-6-d shgc-0.33 100%S (2)24 0.330 23.4 562 11.0 0 264
E -Gls-4A-6-d shgc-0.33 0%S (2)24 0.330 23.4 562 35.8 0 858
N -Gls-4A-6-d shgc-0.33 100%S 21 0.330 23.4 492 11.0 0 231
UP-Ceil-16DR-44 22.5 X 10.5 236.2 0.022 1.6 369 0.5 0 125
Floor-19D-0sp 10.5 X 22.5 236.2 0.368 1.2 292 0.2 0 58
Subtotals for Structure:3,385 0 1,608
Infil.: Win.: 4.6, Sum.: 0.0 309 0.974 301 0.000 0 0
Room Totals:3,686 0 1,608
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 10
Detailed Room Loads - Room 4 - Kitchen (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:24.5 ft.System Number:1
Room Width:8.5 ft.Zone Number:1
Area:208.3 sq.ft.Supply Air:10 CFM
Ceiling Height:10.0 ft.Supply Air Changes:0.3 AC/hr
Volume:2,083 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:1 CFM
Runout Air:0 CFM Percent of Supply.:14 %
Actual Summer Vent.:1 CFM
Percent of Supply:9 %
Actual Winter Infil.:1 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
E -Wall-12F-0bw 8.5 X 8 68 0.065 4.6 314 0.3 0 20
UP-Ceil-16DR-44 24.5 X 8.5 208.2 0.022 1.6 325 0.5 0 110
Floor-19D-0sp 8.5 X 24.5 208.2 0.368 1.2 257 0.2 0 51
Subtotals for Structure:896 0 181
Infil.: Win.: 1.0, Sum.: 0.0 68 0.971 66 0.000 0 0
Room Totals:962 0 181
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 11
Detailed Room Loads - Room 5 - Bedroom 3 (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:12.0 ft.System Number:1
Room Width:10.5 ft.Zone Number:1
Area:126.0 sq.ft.Supply Air:30 CFM
Ceiling Height:8.0 ft.Supply Air Changes:1.8 AC/hr
Volume:1,008 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:2 CFM
Runout Air:0 CFM Percent of Supply.:5 %
Actual Summer Vent.:3 CFM
Percent of Supply:9 %
Actual Winter Infil.:1 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
E -Wall-12F-0bw 10.5 X 8 72 0.065 4.6 332 0.3 0 22
E -Gls-4A-6-d shgc-0.33 0%S 12 0.330 23.4 281 35.8 0 429
UP-Ceil-16DR-44 12 X 10.5 126 0.022 1.6 197 0.5 0 67
Floor-19D-0sp 10.5 X 12 126 0.368 1.2 156 0.2 0 31
Subtotals for Structure:966 0 549
Infil.: Win.: 1.3, Sum.: 0.0 84 0.976 82 0.000 0 0
Room Totals:1,048 0 549
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 12
Detailed Room Loads - Room 6 - Laundry Room / Hall (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:8.0 ft.System Number:1
Room Width:8.0 ft.Zone Number:1
Area:64.0 sq.ft.Supply Air:4 CFM
Ceiling Height:8.0 ft.Supply Air Changes:0.5 AC/hr
Volume:512 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:1 CFM
Runout Air:0 CFM Percent of Supply.:25 %
Actual Summer Vent.:0 CFM
Percent of Supply:9 %
Actual Winter Infil.:2 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
W -Wall-12F-0bw 13 X 8 104 0.065 4.6 480 0.3 0 31
UP-Ceil-16DR-44 8 X 8 64 0.022 1.6 100 0.5 0 34
Floor-19D-0sp 8 X 8 64 0.368 1.2 79 0.2 0 16
Subtotals for Structure:659 0 81
Infil.: Win.: 1.6, Sum.: 0.0 104 0.971 101 0.000 0 0
Room Totals:760 0 81
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 13
Detailed Room Loads - Room 7 - Bath 3 / Hall (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:6.0 ft.System Number:1
Room Width:18.0 ft.Zone Number:1
Area:108.0 sq.ft.Supply Air:13 CFM
Ceiling Height:8.0 ft.Supply Air Changes:0.9 AC/hr
Volume:864 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:1 CFM
Runout Air:0 CFM Percent of Supply.:7 %
Actual Summer Vent.:1 CFM
Percent of Supply:9 %
Actual Winter Infil.:1 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
E -Wall-12F-0bw 6 X 8 44 0.065 4.6 203 0.3 0 13
E -Gls-4A-6-d shgc-0.33 0%S 4 0.330 23.4 94 35.8 0 143
UP-Ceil-16DR-44 6 X 18 108 0.022 1.6 169 0.5 0 57
Floor-19D-0sp 18 X 6 108 0.368 1.2 133 0.2 0 26
Subtotals for Structure:599 0 239
Infil.: Win.: 0.7, Sum.: 0.0 48 0.979 47 0.000 0 0
Room Totals:646 0 239
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 14
Detailed Room Loads - Room 8 - Foyer (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:7.0 ft.System Number:1
Room Width:7.0 ft.Zone Number:1
Area:49.0 sq.ft.Supply Air:12 CFM
Ceiling Height:8.0 ft.Supply Air Changes:1.9 AC/hr
Volume:392 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:2 CFM
Runout Air:0 CFM Percent of Supply.:15 %
Actual Summer Vent.:1 CFM
Percent of Supply:9 %
Actual Winter Infil.:2 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
W -Wall-12F-0bw 7 X 8 56 0.065 4.6 258 0.3 0 17
S -Wall-12F-0bw 7 X 8 35 0.065 4.6 162 0.3 0 10
S -Door-11D 3 X 7 21 0.390 27.7 581 7.8 0 164
UP-Ceil-16DR-44 7 X 7 49 0.022 1.6 77 0.5 0 26
Floor-19D-0sp 7 X 7 49 0.368 1.2 60 0.2 0 12
Subtotals for Structure:1,138 0 229
Infil.: Win.: 1.7, Sum.: 0.0 112 0.973 109 0.000 0 0
Room Totals:1,247 0 229
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 15
Detailed Room Loads - Room 9 - Bedroom 2 (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:12.0 ft.System Number:1
Room Width:13.0 ft.Zone Number:1
Area:156.0 sq.ft.Supply Air:41 CFM
Ceiling Height:8.0 ft.Supply Air Changes:2.0 AC/hr
Volume:1,248 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:3 CFM
Runout Air:0 CFM Percent of Supply.:8 %
Actual Summer Vent.:4 CFM
Percent of Supply:9 %
Actual Winter Infil.:4 CFM
Actual Summer Infil.:0 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
E -Wall-12F-0bw 13 X 8 92 0.065 4.6 425 0.3 0 28
S -Wall-12F-0bw 12 X 8 88 0.065 4.6 406 0.3 0 26
N -Wall-12F-0bw 5 X 8 40 0.065 4.6 185 0.3 0 12
S -Gls-4A-6-d shgc-0.33 0%S (2)8 0.330 23.4 188 18.3 0 146
E -Gls-4A-6-d shgc-0.33 0%S 12 0.330 23.4 281 35.8 0 429
UP-Ceil-16DR-44 12 X 13 156 0.022 1.6 244 0.5 0 82
Floor-19D-0sp 13 X 12 156 0.368 1.2 193 0.2 0 38
Subtotals for Structure:1,922 0 761
Infil.: Win.: 3.6, Sum.: 0.0 240 0.975 234 0.000 0 0
Room Totals:2,156 0 761
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
Air-City Heating & A/C LLC Lot 21 Bonnie Brae Subdivision
Loveland, CO 80538 Page 16
System 1 Room Load Summary
No
Room
Name
Area
SF
Htg
Sens
Btuh
Min
Htg
CFM
Run
Duct
Size
Run
Duct
Vel
Clg
Sens
Btuh
Clg
Lat
Btuh
Min
Clg
CFM
Act
Sys
CFM
---Zone 1---
1 Master Suite 162 1,941 30 1-0 0 386 0 21 21
2 Master Bath
/closet
122 1,422 22 1-0 0 220 0 12 12
3 Dinning /
Greatroom
236 3,686 57 1-0 0 1,608 0 88 88
4 Kitchen 208 962 15 1-0 0 181 0 10 10
5 Bedroom 3 126 1,048 16 1-0 0 549 0 30 30
6 Laundry Room /
Hall
64 760 12 1-0 0 81 0 4 4
7 Bath 3 / Hall 108 646 10 1-0 0 239 0 13 13
8 Foyer 49 1,247 19 1-0 0 229 0 12 12
9 Bedroom 2 156 2,156 34 1-0 0 761 0 41 41
Ventilation 1,322 261 -184
System 1 total 1,231 15,190 216 4,515 -184 232 232
Cooling System Summary
Cooling
Tons
Sensible/Latent
Split
Sensible
Btuh
Latent
Btuh
Total
Btuh
Net Required:0.38 104% / -4%4,515 -184 4,515
Equipment Data
Heating System Cooling System
Type:Natural Gas Furnace Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency:0 AFUE 0 SEER
Sound:0 0
Capacity:0 Btuh 0 Btuh
Sensible Capacity:n/a 0 Btuh
Latent Capacity:n/a 0 Btuh
C:\ ...\Lot 21 Bonnie Brae Subdivision.rh9 Tuesday, January 4, 2022, 4:32 PM
Reviewed by
SAFEbuilt
02/04/2022