HomeMy WebLinkAboutPLANS Accessory Building 1750 S Saint Vrain 2021-12-15OHE
OHE
OHE
OHE
OHE
O
HE
OHE
OHE
OHE
O
HE
O H E
O H E
O H E
O H E
O H E
O H E
O H E
O H E
O H E
S O U T H S AI N T V R AI N (H W Y 7)
S73° 53' 32" E 266.67'
FOUND #4
REBAR LS# 9485
FOUND #4
REBAR LS# 6499N43° 22' 47" E 97.30'N26° 27' 50" E 161.57'
STEEL FENCE POST
FOUND #4
REBAR LS# 9485
NEIG
HB
O
R'S PA
RKIN
G
N61° 20' 32" W 221.97'
N 3 8° 5 6' 2 1" E 3 1 8.6 2'
FOUND #4
REBAR LS# 6499
OVERHEAD ELECTRIC
GRAVEL DRIVE OUTHOUSE
SEPTIC
TANK
S
G
U
E
S
T
R
O
O
M
EXISTING
ONE STORY
HOUSE
PATIO PROPANE
9.40'
55.20'
2 9.0 0'
2
2.0
0'
1 2.6 0'
1
6.0
0'
1 6.0 0'
1 2.0 0'
2 0.0 0'
3
9.5
0'
3 1.6 0'
78.80'
5 0.0 0'
4
0.0
0'
PROPSOED
GARAGE
2,000 SQ. FT.
F
R
O
N
T S
E
T
B
A
C
K
2
5.0
0'
10.00'
SIDE SETBACK
10.00'
REAR SETBACK
1
5
.0
0'
15.00'
REAR SETBACK
10.00'
SIDE SETBACK
ELECTRICAL
PANEL
N
2
7.0
0'
SHEET NO.
REV.DESCRIPTION DATE ISSUED
PLAN DATES
15940 S. GOLDEN ROAD
GOLDEN, COLORADO
303.284.1276
ARCHITECTURE
STUDIO 646 ______________
12
/
7
/
2
0
2
1
5
:
0
4
:
4
2
P
M
ARCHITECTURAL SITE
PLAN
21-044
PERMIT SUBMITTAL 12.07.2021
A-100
NELSON'S
GARAGE
1750 S. SAINT VRAIN AVE ESTES
PARK, CO 80517
12.07.2021
1" = 20'-0"1 ARCHITECTURAL SITE PLAN
TOWN OF ESTES PARK
ADOPTED BUILDING CODES:
2015 INTERNATIONAL BUILDING CODES WITH LOCAL AMENDMENTS AND SIGNIFICATN CHANGES
IRC -INTERNATIONAL RESIDENTIAL CODE LOCAL AMENDMENTS &, SIGNIFICANT CHANGES
IRC -LOCAL AMENDMENTS REGARDING VACATION HOMES
IFGC -INTERNATIONAL FUEL GAS CODE LOCAL AMENDMENTS &, SIGNIFICANT CHANGES
IMC -INTERNATIONAL MECHANICAL CODE LOCAL AMENDMENTS &, SIGNIFICANT CHANGES
IPC -INTERNATIONAL PLUMBING CODE LOCAL AMENDMENTS &, SIGNIFICANT CHANGES
IPMC -INTERNATIONAL PLUMBING CODE LOCAL AMENDMENTS &, SIGNIFICANT CHANGES
IFC -ESTES VALLEY FIRE PROTECTION DISTRICT REGULATIONS
IECC -INTERNATIONAL ENERGY CONSERVATION CODE LOCAL AMENDMENTS &, SIGNIFICANT CHANGES
ADDRESS: 1750 S SAINT VRAIN AVE.
CITY AND STATE: ESTES PARK, COLORADO
COUNTY: LARIMER COUNTY
ZONE LOT AREA: 65,340 S.F. (1.50 ACRES)
ZONING DISTRICT: ESTATE: 1/2 ACRE MIN (E)
SITE STATISTICS:
All work shall be performed by Licensed
Contractors OR work shall be performed
by the homeowner residing in the dwelling.
Issuance of a permit or approval of these
construction documents shall not be construed
to be a permit for, or an approval of, any
violation of any of the provisions of the adopted
codes or of other ordinances of this jurisdiction.
A permit presuming to give authority to violate
or cancel the provisions of these codes shall be
invalid.
PLANS AND CONSTRUCTION
SHALL MEET THE 2015 IRC, 2020
NEC AND ALL APPLICABLE
MUNICIPAL CODES & ORDINANCES
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and have on
site for inspector
This structure must comply
with the requirements of the
2020 National Electrical Code
ALL ARCHITECTURAL PLANS, ENGINEERED PLANS,
SOILS REPORTS, TRUSS DRAWINGS, ENERGY CODE
REPORTS/RESCHECKS MUST BE ONSITE FOR
INSPECTORS REVIEW.
Accessory Structures shall not be used for
living or sleeping quarters and shall not
contain plumbing capable of facilitating a
bathroom or kitchen.
OPEN HOLE INSPECTION IS REQUIRED
BY GEOTECHNICAL ENGINEER AT TIME
OF EXCAVATION - DUE TO NO SOILS
REPORT - TO VERIFY SOIL BEARING
CONDITIONS FOR FOOTING DESIGN
REVIEWED BY
SAFEBUILT - PBLAND
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
12/15/2021
A-102
1
A-1024
A-102
A-102
2
3
1
A-103
50' - 0"
40
'
-
0
"
6030
25' - 0"25' - 0"
ELECTRICAL
PANEL
BATHROOM
8' - 0"
5'
-
2
"
6030
RO
O
F
R
I
D
G
E
A
B
O
V
E
9' - 0"12' - 6"7' - 9"17' - 0"3' - 9"
50' - 0"
40
'
-
0
"
10 X 10 OVERHEAD DOOR14 X 10 OVERHEAD DOOR
30
6
8
3068
4' - 0"2' - 6"
PROPOSED GARAGE
CONCRETE SLAB
UNINSULATED
GFCI
33
'
-
7
1
/
2
"
5'
-
5
1
/
2
"
49' - 1"
22
0
V
11
'
-
0
"
N
PROVIDE ELEC.HEAT
AND INSULATE WALLS
TO R-19 AND CEILING R-49
BE
A
M
A
N
D
W
A
L
L
A
B
O
V
E
BE
A
M
A
N
D
W
A
L
L
A
B
O
V
E
WALL BELOW
WALL BELOW
WA
L
L
B
E
L
O
W
WA
L
L
B
E
L
O
W
2' - 0"
O.
H
.
2'
-
0
"
2' - 0"
O.
H
.
2'
-
0
"
5" / 12"5" / 12"ASPHALT SHINGLE
ROOF
ASPHALT SHINGLE
ROOF
15' - 0"20' - 0"15' - 0"
SHEET NO.
REV. DESCRIPTION DATE ISSUED
PLAN DATES
15940 S. GOLDEN ROAD
GOLDEN, COLORADO
303.284.1276
ARCHITECTURE
STUDIO 646 ______________
12
/
7
/
2
0
2
1
5
:
0
4
:
4
3
P
M
FLOOR PLAN
21-044
PERMIT SUBMITTAL 12.07.2021
A-101
NELSON'S
GARAGE
1750 S. SAINT VRAIN AVE ESTES
PARK, CO 80517
12.07.2021
1/4" = 1'-0"1 GARAGE FLOOR PLAN W/ ELECTRICAL
1/4" = 1'-0"2 ROOF PLAN
Glazing installed in hazardous locations as defined
in Section R308.4 shall be Tempered Glass
Provide 50 cfm fan in bathroom - vented to exterior -
when no natural ventilation is provided by window
Fire Block shall be provided in concealed wood
framed walls per locations designated in R302.11
Appliance and all Equipment Vent Terminations
shall be per manufacturers specifications
Any New Gas piping shall be tested for not less than 15
min. @ 1 1/2 times the proposed maximum working
pressure but not less than 10 psig. - before it is put into
service. See section 2417.4.1 and local amendments
Toilets & Lavatories shall be provided with a min. of 21
inches in front each fixture
- each side of Toilets shall have 15 inches from the center
line of the toilet and any sidewall or other obstructions.
Do not remove Manufacturers stickers on
windows until after all final inspections
PROVIDE ROOF VENT CALCULATIONS
SHOWING # OF VENTS REQUIRED FOR
INSPECTORS REVIEW.
ROOF VENTS REQUIRED FOR ENCLOSED
RAFTER SPACES PER R806 &
MANUFACTURERS SPECIFICATIONS
Provide gutters or a controlled method of water
disposal from roofs - that will collect and
discharge to the ground surface not less than 5'
from foundation or to an approved drainage
system. R801.3
FLASHING SHALL BE INSTALLED IN A MANNER
THAT WILL PREVENT MOISTURE ENTERING
WALLS AND ROOFS R903.2
ICE AND WATER SHEILD IS REQUIRED
Manufacturer's installation instructions, as required
by code, shall be available on the job site at the time
of inspection. R106.1.2
2018 PRESCRIPTIVE INSULATION VALUES:
SLAB EDGE = R-10 for 2 ft.
FLOOR = R-30
WALLS = R-20 or R-13+R-5 continuous
ATTIC/CEILING = R-49
FENESTRATION VALUE:
U-FACTOR = R-0.30
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY
SAFEBUILT - PBLAND
Min. one outlet per parking space
Garage receptacle outlets shall be
provided with 20 amp circuit and GFCI
Protected.
Only the outdoor receptacle outlets are
permitted to be added to this circuit.
Bathrooms - Min one - 20 amp circuit -
bathroom countertops or similar work
surfaces shall be GFCI protected - Typical
for each bathroom (2020 NEC 210.8)
Receptacles cannot be installed within a
zone of 3' horizontally & 8' from the
bathtub rim or shower stall threshold
(410.10D - 2020 NEC)
Outdoor receptacles shall be a min 12" from
final grade, roof surfaces or similar locations.
Laundry room, Dishwasher, Unfinished
basement, garage, & outdoor receptacles
shall have GFCI protection.
T.O. STUD LEVEL 1
116' -0"
16
'
-
0
"
T.O. SLAB
100' -0"
60"x30"
10 X 10 OVERHEAD DOOR
14 X 10 OVERHEAD DOOR
3068
6" FASCIA
BOARD
GUTTER
2' - 0"
ASPHALT
SHINGLE ROOF
HD
R
.
8'
-
0
"
8" LAP SIDING
(TYPICAL)
5"
12"
T.O. STUD LEVEL 1
116' -0"
T.O. SLAB
100' -0"
30"x60"
8' -0" HDR
16
'
-
0
"
O.H.
13' - 0"2' - 0"
ASPHALT
SHINGLE ROOF
30
'
-
0
"
T.O. STUD LEVEL 1
116' -0"
T.O. SLAB
100' -0"
30" GRADE CHANGE
16
'
-
0
"
O.H.
2' - 0"
O.H.
2' - 0"
ASPHALT
SHINGLE ROOF
T.O. STUD LEVEL 1
116' -0"
T.O. SLAB
100' -0"
30" GRADE CHANGE
16
'
-
0
"
O.H.
2' - 0"
O.H.
2' - 0"
ASPHALT
SHINGLE ROOF
8" LAP SIDING
(TYPICAL)
SHEET NO.
REV. DESCRIPTION DATE ISSUED
PLAN DATES
15940 S. GOLDEN ROAD
GOLDEN, COLORADO
303.284.1276
ARCHITECTURE
STUDIO 646 ______________
12
/
7
/
2
0
2
1
5
:
0
4
:
4
4
P
M
GARAGE EXTERIOR
ELEVATIONS
21-044
PERMIT SUBMITTAL 12.07.2021
A-102
NELSON'S
GARAGE
1750 S. SAINT VRAIN AVE ESTES
PARK, CO 80517
12.07.2021
1/4" = 1'-0"1 FRONT ELEVATION
1/4" = 1'-0"2 REAR ELEVATION
1/4" = 1'-0"3 LEFT ELEVATION
1/4" = 1'-0"4 RIGHT ELEVATION
General Elevation Notes:
- Asphalt shingles to meet nominal 135 MPH
wind-speed
- All stone, stucco and siding to have a barrier
underneath at exterior walls
- Roof slopes from 2:12 up to 4:12 require double
underlayment
- Sills less than 24" - w/72+" of fall require fall
protection
- Roof Ventilation per R806
- All stairs, landings, guards, rails and walking
surfaces to comply with R311 and R312
- All Exterior Coverings shall comply with R703
- All Roofing materials shall comply with R905
- Water-resistive barrier required per R703.2
- Drip edge required on all rakes and eaves
- Ice and Water Shield is required
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY
SAFEBUILT - PBLAND
T.O. STUD LEVEL 1
116' -0"
CONCRETE SLAB INSIDE
RE: STRUCT
T.O. SLAB
100' -0"
6030
8' -0" HDR
BATHROOM
PRE-ENGINEERED ROOF TRUSSES
FOUND. WALL BEYOND
2' - 0"2' - 0"
GRADE BEYOND
MI
N
.
4"
MI
N
.
4"
HE
E
L
1'
-
4
"
16
'
-
0
"
8'
-
6
"
16
'
-
0
"
BEAM RE: STRUCTURAL
5"
12"
5"
12"
15' - 0"20' - 0"15' - 0"
2' - 0"10' - 0"10' - 0"2' - 0"
30
'
-
0
"
HE
E
L
1'
-
4
"
SHEET NO.
REV. DESCRIPTION DATE ISSUED
PLAN DATES
15940 S. GOLDEN ROAD
GOLDEN, COLORADO
303.284.1276
ARCHITECTURE
STUDIO 646 ______________
12
/
7
/
2
0
2
1
5
:
0
4
:
4
4
P
M
BUILDING SECTION
21-044
PERMIT SUBMITTAL 12.07.2021
A-103
NELSON'S
GARAGE
1750 S. SAINT VRAIN AVE ESTES
PARK, CO 80517
12.07.2021
1/4" = 1'-0"1 GARAGE BUILDING SECTION
Pre-Engineered Truss
Drawings to be on-site for
Inspectors Review
Interior
Finishes per
R702
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and have on
site for inspector
REVIEWED BY
SAFEBUILT - PBLAND
REVIEWED BY
SAFEBUILT - PBLAND
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
MIN. 3' SEPARATION BETWEEN
GROUNDWATER AND BOTTOM OF
FOUNDATION SYSTEM
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
12/15/2021
REVIEWED BY
SAFEBUILT - PBLAND
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
REVIEWED BY
SAFEBUILT - PBLAND
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
REVIEWED BY
SAFEBUILT - PBLAND
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
OPEN HOLE INSPECTION IS REQUIRED BY
GEOTECHNICAL ENGINEER AT TIME OF EXCAVATION
- DUE TO NO SOILS REPORT - TO VERIFY SOIL
BEARING CONDITIONS FOR FOOTING DESIGN
REVIEWED BY
SAFEBUILT - PBLAND
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
A01
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A01
A01
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A02
A01
40
-
0
0
-
0
0
40
-
0
0
-
0
0
IRC 2018
65.0 lb/ft²
10.0 lb/ft²
10.0 lb/ft²
175 mph
TRUSS SPECIFICATIONS:
SPACING......................
PITCH............................
BOTTOM CHORD.....
HEEL HEIGHT..............
OVERHANG.................
CANTILEVER................
OUTRIGGERS..............
BEARING SIZE............
2-0-0 o.c.
4/12
FLAT
4-0
1-0-0
NONE
NONE
2x4
ROOF DESIGN CRITERIA:
CODE....................
SNOW.................
TCDL.....................
BCDL.....................
WIND...................
GENERAL NOTES:
> TRUSSES ARE BUILT TO CUSTOMER'S SPECIFICATIONS/ NO FIELD
VERIFICATION REQUIRED
> SUPPORTED GABLE ENDS PROVIDED W/ VERTICAL 2X4'S @ 16" ON
CENTER.
> STRUCTURAL GABLE ENDS PROVIDED W/ VERTICAL 2X4'S @ 16" ON
CENTER.
> STRUCTURAL CONNECTORS USED IN THIS DESIGN ARE MANUFACTURED
BY USP. ALLOWABLE LOAD CAPACITIES ARE EQUAL TO OR GREATER THAN
OTHER CONNECTOR SPECIFICATIONS.
> THE BUILDER/PROJECT ENGINEER IS SOLEY RESPONSIBLE FOR THE REVIEW
AND APPROVAL OF ALL DESIGN CRITERIA TO INSURE ACCURACY AND FULL
COMPLIANCE WITH EXISTING APPLICABLE BUILDING CODE REQUIREMENTS.
INCLUDING ALL TIE DOWN CONNECTIONS NEEDED FOR PROPER TRUSS
INSTALLATION. RT7A CLIPS ARE PROVIDED BUT MAY NOT MEET ALL UPLIFT
REQUIREMENTS.
B01
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B02
B01
21-00-00
40
-
0
0
-
0
0
-
T
H
I
S
I
S
A
T
R
U
S
S
P
L
A
C
E
M
E
N
T
D
I
A
G
R
A
M
O
N
L
Y
.
T
h
e
s
e
t
r
u
s
s
e
s
a
r
e
d
e
s
i
g
n
e
d
a
s
i
n
d
i
vi
d
u
a
l
b
u
i
l
d
i
n
g
c
o
m
p
o
n
e
n
t
s
t
h
a
t
a
r
e
t
o
b
e
in
c
o
r
p
o
r
a
t
e
d
i
n
t
o
t
h
e
b
u
i
l
d
i
n
g
d
e
s
i
g
n
a
t
t
h
e
s
p
e
c
i
f
i
c
a
t
i
o
n
o
f
t
h
e
b
u
i
l
d
i
n
g
d
e
s
i
g
n
e
r
.
S
e
e
i
n
d
i
v
i
d
u
a
l
e
n
g
i
n
e
e
r
i
n
g
d
r
a
w
i
n
g
s
t
o
i
d
e
n
t
i
f
y
t
r
u
s
s
pl
a
c
e
m
e
n
t
o
n
d
r
a
w
i
n
g
.
B
u
i
l
d
i
n
g
d
e
s
i
g
n
e
r
i
s
r
e
s
p
o
n
s
i
b
l
e
f
o
r
t
e
m
p
o
r
a
r
y
a
n
d
pe
r
m
a
m
e
n
t
b
r
a
c
i
n
g
o
f
t
h
e
r
o
o
f
a
n
d
f
l
o
o
r
s
y
s
t
e
m
s
f
o
r
ov
e
r
a
l
l
s
t
r
u
c
t
u
r
e
;
a
n
d
t
h
e
d
e
s
i
g
n
o
f
t
he
t
r
u
s
s
s
u
p
p
o
r
t
s
y
s
t
e
m
,
i
n
c
l
u
d
i
n
g
b
ut
n
o
t
l
i
m
i
t
e
d
t
o
h
e
a
d
e
r
s
,
b
e
a
m
s
,
b
e
a
r
i
n
g
w
a
l
l
s
,
a
n
d
c
o
l
u
m
n
s
.
-
F
o
r
g
e
n
e
r
a
l
g
u
i
d
a
n
c
e
r
e
g
a
r
d
i
n
g
b
r
a
c
i
n
g
,
p
l
e
a
s
e
r
e
f
e
r
t
o
T
r
u
s
s
P
l
a
t
e
I
n
s
t
it
u
t
e
'
s
"
B
u
i
l
d
i
n
g
C
o
m
p
o
n
e
n
t
S
a
f
e
t
y
I
n
f
o
r
m
a
t
i
o
n
"
(
B
C
S
I
)
b
o
o
k
,
or
B
C
S
I
-
B
1
f
o
r
m
a
v
a
i
l
a
b
l
e
a
t
t
p
i
n
s
t
.
o
r
g
.
-
A
n
y
s
t
r
u
c
t
u
r
a
l
d
e
t
a
i
l
s
c
a
l
l
e
d
o
u
t
o
n
l
a
y
o
u
t
a
r
e
b
a
s
e
d
o
n
t
h
e
i
n
t
e
r
p
r
e
t
a
t
i
on
o
f
t
h
e
s
t
r
u
c
t
u
r
a
l
p
l
a
n
s
,
a
n
d
a
r
e
n
o
t
s
p
e
c
i
f
i
e
d
b
y
t
h
e
t
r
u
s
s
de
s
i
g
n
e
r
o
r
H
i
g
h
P
l
a
t
e
a
u
T
r
u
s
s
I
n
c
.
NE
L
S
O
N
'
S
C
U
S
T
O
M
C
O
N
S
T
R
U
C
T
I
O
N
DA
T
E
C
I
T
Y
,
S
T
A
T
E
,
Z
I
P
Es
t
e
s
P
a
r
k
,
C
O
21
-
0
7
0
7
JO
B
#
Re
v
i
e
w
a
n
d
a
p
p
r
o
v
a
l
o
f
t
h
i
s
l
a
y
o
u
t
a
n
d
c
o
r
r
e
s
p
o
n
d
i
n
g
e
n
g
i
n
e
e
r
i
n
g
dr
a
w
i
n
g
s
b
y
t
h
e
c
l
i
e
n
t
o
r
c
l
i
e
n
t
'
s
a
g
e
n
t
a
r
e
r
e
q
u
i
r
e
d
b
e
f
o
r
e
t
r
u
s
s
e
s
c
a
n
be
s
e
n
t
t
o
p
r
o
d
u
c
t
i
o
n
Ap
p
r
o
v
e
d
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
D
a
t
e
_
_
_
_
_
_
_
_
_
_
AD
D
R
E
S
S
PR
O
J
E
C
T
TB
D
CU
S
T
O
M
E
R
Ne
l
s
o
n
G
a
r
a
g
e
11
/
2
9
/
2
0
2
1
ROOF TRUSS LAYOUT
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
17
5
0
S
O
U
T
H
S
A
I
N
T
V
R
A
I
N
A
V
E
.
412
=3x4
0-4-120-3-8
=5x8
0-0-12
0-3-8
=3x4
=3x5
=3x4
1 2
21 20 19 18 17 16 15 14
13
3 4
5
6
7
8
9
10
11
12
W1
T1
T2
B1
ST8ST7ST6
ST5ST4ST3ST2ST1
1-4-0
-1-4-0
1-10-12
1-10-12
12-7-4
14-6-0
14-6-0
5-3-5
0-6-1
4-10
-4
0-3-8
0-3-8 0-10
-2
1-1-10
Plate Offsets (X, Y): [2:0-3-8,Edge], [2:0-4-12,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 65.0 Plate Grip DOL 1.00 TC 0.77 Vert(LL)n/a -n/a 999 MT20 169/123
(Roof Snow = 65.0)Lumber DOL 1.00 BC 0.15 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.23 Horz(CT)0.00 13 n/a n/a
BCLL 0.0 *Code IRC2018/TPI2014 Matrix-S
BCDL 10.0 Weight: 62 lb FT = 20%
LUMBER
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
T2:2x4 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud
OTHERS 2x4 WW Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.REACTIONS All bearings 14-6-0.
(lb) -Max Horiz 2=481 (LC 9)
Max Uplift All uplift 100 (lb) or less at joint(s) 13, 20 except 2=-235 (LC 8),
14=-118 (LC 8), 15=-101 (LC 12), 16=-113 (LC 8), 17=-107 (LC
12), 18=-109 (LC 8), 19=-115 (LC 12), 21=-217 (LC 12)
Max Grav All reactions 250 (lb) or less at joint(s) 13, 20 except 2=520 (LC
1), 14=315 (LC 19), 15=323 (LC 19), 16=316 (LC 19), 17=318
(LC 19), 18=312 (LC 19), 19=346 (LC 19), 21=609 (LC 19)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-406/32, 3-4=-400/89, 4-5=-310/17, 5-6=-288/50, 6-7=-256/44
WEBS 11-14=-287/117, 10-15=-296/216, 9-16=-289/206, 8-17=-290/204, 7-18=-287/203, 6-19=-309/219, 4-21=-519/404
NOTES
1)Wind: ASCE 7-16; Vult=175mph (3-second gust) Vasd=138mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II;Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) -1-4-0 to 1-8-0, Exterior(2N) 1-8-0 to 11-4-4, Corner(3E) 11-4-4 to 14-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1-2002.
3)TCLL: ASCE 7-16; Pf=65.0 psf (Lum DOL=1.00 Plate DOL=1.00); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9;Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 65.0 psf on overhangs non-concurrent with other live loads.
6)All plates are 2x4 MT20 unless otherwise indicated.
7)Gable requires continuous bottom chord bearing.
8)Gable studs spaced at 1-4-0 oc.
9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and
any other members.
11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 20 except (jt=lb) 2=235, 14=117, 15=100, 16=113,
17=107, 18=108, 19=114, 21=217.
12)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply Nelson, Estes Park
21-0707 A01 4 1Monopitch Supported Gable Job Reference (optional)
High Plateau Truss, Inc., Commerce City, CO 80022, BStrange Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Nov 29 14:01:55 Page: 1
ID:vGJF42IkfkzH?I_kkMYP9?yPqkh-EMpLF_sb9FtVMCYK_xwGDRJH?p2DnHnZdOFOZAyEHox
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
412
=5x8
0-1-14
=2x4
=7x12
0
-
5
-
4
=5x8
0-3-0
=4x6
1
2
8
7
6
9
10
11
3
12
4 5
T2
T1
W3
B1
W1 W2
1-4-0
-1-4-0
7-2-15
7-2-15
7-3-1
14-6-0
0-3-4
14-6-0
6-11-13
14-2-12
7-2-15
7-2-15
5-9-2
0-6-1
5-4-1
Plate Offsets (X, Y): [3:0-6-0,0-5-4], [7:0-4-0,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 65.0 Plate Grip DOL 1.00 TC 0.87 Vert(LL)-0.12 2-8 >999 240 MT20 169/123
(Roof Snow = 65.0)Lumber DOL 1.00 BC 0.64 Vert(CT)-0.17 2-8 >990 180
TCDL 10.0 Rep Stress Incr YES WB 0.52 Horz(CT)0.05 7 n/a n/a
BCLL 0.0 *Code IRC2018/TPI2014 Matrix-S
BCDL 10.0 Weight: 61 lb FT = 20%
LUMBER
TOP CHORD 2x6 SPF 2100F 1.8E
BOT CHORD 2x4 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
W2:2x4 SPF 1650F 1.5E
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-4-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 7-10-6 oc bracing.
WEBS 1 Row at midpt 3-7
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=1437/0-5-8, (min. 0-2-10), 7=1223/ Mechanical, (min. 0-1-8)
Max Horiz 2=522 (LC 9)
Max Uplift 2=-641 (LC 8), 7=-539 (LC 8)
Max Grav 2=1678 (LC 19), 7=1675 (LC 19)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-9=-2862/858, 9-10=-2704/864, 10-11=-2659/868, 3-11=-2483/881, 3-12=-326/90, 4-7=-674/339
BOT CHORD 2-8=-816/2544, 7-8=-818/2540
WEBS 3-8=0/321, 3-7=-2675/1075
NOTES
1)Wind: ASCE 7-16; Vult=175mph (3-second gust) Vasd=138mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II;Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Exterior(2E) -1-4-0 to 1-8-0, Interior (1) 1-8-0 to 10-3-1, Exterior(2R) 10-3-1 to 14-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2)TCLL: ASCE 7-16; Pf=65.0 psf (Lum DOL=1.00 Plate DOL=1.00); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9;Cs=1.00; Ct=1.10
3)Unbalanced snow loads have been considered for this design.
4)This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 65.0 psf on overhangs non-concurrent with other live loads.
5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and
any other members.
7)Refer to girder(s) for truss to truss connections.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 539 lb uplift at joint 7 and 641 lb uplift at joint 2.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply Nelson, Estes Park
21-0707 A02 38 1Jack-Closed Job Reference (optional)
High Plateau Truss, Inc., Commerce City, CO 80022, BStrange Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Nov 29 14:01:56 Page: 1
ID:vGJF42IkfkzH?I_kkMYP9?yPqkh-Alw6ggtrgs7DbWij6MykIsObwdd4F6ls5ikVe2yEHov
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
412
212=4x8
0-1-2
=3x8
0
-
3
-
8
0 -8 -1
=3x8
0
-
2
-
1
2
1 -4 -15
=4x6
0 -2 -0
=4x6
=5x6
=4x6
0-2-0
=3x8
0-2-12
1-4-15
=3x8
0-3-8
0-8-1
=4x8
0-1-2 171162
28 182719
153
26 2025212422
4 14
23
5 13
6 122930711
8 10
9
T1 T1
T2 T2
B1 B1
HW1 HW1
ST6ST5
ST4ST3ST2ST1
ST5
ST4 ST3 ST2 ST1
1-4-0
22-4-0
1-4-0
-1-4-0
1-10-12
21-0-0
1-10-12
1-10-12
8-7-4
10-6-0
8-7-4
19-1-4
0-5-8
21-0-0
0-5-8
0-5-8
10-0-8
10-6-0
10-0-8
20-6-8
4-0-3
1-0-0 1-8-1
0-6-3
0-6-3 1-1-6
1-7-9
2-4-10
4-0-3
Plate Offsets (X, Y): [2:0-3-8,Edge], [2:0-2-12,1-4-15], [16:0-3-8,Edge], [16:0-2-12,1-4-15]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 65.0 Plate Grip DOL 1.00 TC 0.45 Vert(LL)n/a -n/a 999 MT20 169/123
(Roof Snow = 65.0)Lumber DOL 1.00 BC 0.07 Vert(CT)n/a -n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.23 Horz(CT)0.00 16 n/a n/a
BCLL 0.0 *Code IRC2018/TPI2014 Matrix-S
BCDL 10.0 Weight: 79 lb FT = 20%
LUMBER
TOP CHORD 2x6 SPF 1650F 1.5E *Except*
T2:2x4 SPF 1650F 1.5E
BOT CHORD 2x4 SPF 1650F 1.5E
OTHERS 2x4 WW Stud
WEDGE Left: 2x4 WW Stud
Right: 2x4 WW Stud
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS All bearings 21-0-0.
(lb) -Max Horiz 2=-146 (LC 13)
Max Uplift All uplift 100 (lb) or less at joint(s) 19, 27 except 2=-288 (LC 8),
16=-279 (LC 9), 18=-277 (LC 13), 20=-119 (LC 13), 21=-110
(LC 9), 22=-107 (LC 13), 24=-110 (LC 12), 25=-110 (LC 8),
26=-117 (LC 12), 28=-236 (LC 12)
Max Grav All reactions 250 (lb) or less at joint(s) 19, 23, 27 except 2=630
(LC 19), 16=608 (LC 20), 18=848 (LC 20), 20=365 (LC 20),
21=305 (LC 20), 22=341 (LC 20), 24=341 (LC 19), 25=306 (LC
19), 26=359 (LC 19), 28=785 (LC 19)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-53/270, 9-10=-53/270
WEBS 8-24=-312/207, 7-25=-282/192, 6-26=-321/164, 4-28=-682/311, 10-22=-312/207, 11-21=-281/192, 12-20=-327/168,
14-18=-738/349
NOTES
1)Wind: ASCE 7-16; Vult=175mph (3-second gust) Vasd=138mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II;Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Corner(3E) -1-4-0 to 1-8-0, Exterior(2N) 1-8-0 to 7-6-0, Corner(3R) 7-6-0 to 13-6-0, Exterior(2N) 13-6-0 to 19-4-0, Corner(3E) 19-4-0 to 22-4-0 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult
qualified building designer as per ANSI/TPI 1-2002.
3)TCLL: ASCE 7-16; Pf=65.0 psf (Lum DOL=1.00 Plate DOL=1.00); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9;Cs=1.00; Ct=1.10
4)Unbalanced snow loads have been considered for this design.
5)This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 65.0 psf on overhangs non-concurrent with other live loads.
6)All plates are 2x4 MT20 unless otherwise indicated.
7)Gable requires continuous bottom chord bearing.
8)Gable studs spaced at 1-4-0 oc.
9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and
any other members.
11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 19 except (jt=lb) 2=288, 16=278, 24=109, 25=109,
26=116, 28=236, 22=106, 21=109, 20=119, 18=277.
Job Truss Truss Type Qty Ply Nelson, Estes Park
21-0707 B01 2 1Scissor Supported Gable Job Reference (optional)
High Plateau Truss, Inc., Commerce City, CO 80022, BStrange Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Nov 29 14:01:56 Page: 1
ID:NTtdHOINQ258cSZwI43eiCyPqkg-Alw6ggtrgs7DbWij6MykIsOhQdluFBHs5ikVe2yEHov
Continued on page 2
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
12)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 23, 16, 24, 25, 26, 27, 28, 22, 21, 20, 19, 18.
13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply Nelson, Estes Park
21-0707 B01 2 1Scissor Supported Gable Job Reference (optional)
High Plateau Truss, Inc., Commerce City, CO 80022, BStrange Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Nov 29 14:01:56 Page: 2
ID:NTtdHOINQ258cSZwI43eiCyPqkg-Alw6ggtrgs7DbWij6MykIsOhQdluFBHs5ikVe2yEHov
PERMIT #21-EP-00570
Field Copy
Print out legibly & in color and
have on site for inspector
412
212=8x12
0 -0 -3
0
-
6
-
4
=5x10
=2x4
=3x5
=7x12
0-4-0
=5x12
0-2-4
=3x5
=2x4
=5x10
=8x12
0-0-30-6-42 8
91
1012
13 1673
11
64
14 15
5
T1 T1
B1 B1
W3
W2W2
W1 W1
HW1 HW1
1-4-0
22-4-0
1-4-0
-1-4-0
5-1-4
10-6-0
5-1-4
15-7-4
5-4-12
5-4-12
5-4-12
21-0-0
0-5-8
0-5-8
0-5-8
21-0-0
4-11-4
5-4-12
4-11-4
20-6-8
5-1-4
10-6-0
5-1-4
15-7-4
1-0-0
4-6-0
1-8-1
Plate Offsets (X, Y): [2:0-0-3,0-6-4], [5:0-6-0,0-2-4], [8:0-0-3,0-6-4], [11:0-6-0,0-4-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 65.0 Plate Grip DOL 1.00 TC 0.62 Vert(LL)-0.30 10-11 >836 240 MT20 197/144
(Roof Snow = 65.0)Lumber DOL 1.00 BC 0.77 Vert(CT)-0.40 10-11 >630 180
TCDL 10.0 Rep Stress Incr YES WB 0.67 Horz(CT)0.22 8 n/a n/a
BCLL 0.0 *Code IRC2018/TPI2014 Matrix-S
BCDL 10.0 Weight: 103 lb FT = 20%
LUMBER
TOP CHORD 2x6 SPF 1650F 1.5E
BOT CHORD 2x6 SPF 1650F 1.5E
WEBS 2x4 WW Stud *Except*
W3:2x4 SPF 1650F 1.5E
SLIDER Left 2x4 WW Stud --2-9-11, Right 2x4 WW Stud --2-9-11
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-0-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-7-13 oc bracing.
MiTek recommends that Stabilizers and required cross bracing be
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS (lb/size)2=1983/0-5-8, (min. 0-3-8), 8=1983/0-5-8, (min. 0-3-8)
Max Horiz 2=-161 (LC 17)
Max Uplift 2=-809 (LC 8), 8=-809 (LC 9)
Max Grav 2=2277 (LC 19), 8=2277 (LC 20)
FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-13=-5354/2021, 3-13=-5084/2026, 3-4=-5076/2034, 4-14=-4301/1961, 5-14=-4225/1972, 5-15=-4225/1972,
6-15=-4301/1961, 6-7=-5076/2034, 7-16=-5084/2026, 8-16=-5354/2021
BOT CHORD 2-12=-1749/4692, 11-12=-1763/4723, 10-11=-1763/4723, 8-10=-1749/4692
WEBS 5-11=-625/1671, 6-11=-886/566, 4-11=-886/566
NOTES
1)Wind: ASCE 7-16; Vult=175mph (3-second gust) Vasd=138mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II;Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C
Exterior(2E) -1-4-0 to 1-8-0, Interior (1) 1-8-0 to 7-6-0, Exterior(2R) 7-6-0 to 13-6-0, Interior (1) 13-6-0 to 19-4-0, Exterior(2E) 19-4-0 to 22-4-0 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2)TCLL: ASCE 7-16; Pf=65.0 psf (Lum DOL=1.00 Plate DOL=1.00); Is=1.0; Rough Cat C; Fully Exp.; Ce=0.9;Cs=1.00; Ct=1.10
3)Unbalanced snow loads have been considered for this design.
4)This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 65.0 psf on overhangs non-concurrent with other live loads.
5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and
any other members.
7)Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 809 lb uplift at joint 2 and 809 lb uplift at joint 8.
9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S)Standard
Job Truss Truss Type Qty Ply Nelson, Estes Park
21-0707 B02 19 1Scissor Job Reference (optional)
High Plateau Truss, Inc., Commerce City, CO 80022, BStrange Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Nov 29 14:01:56 Page: 1
ID:NTtdHOINQ258cSZwI43eiCyPqkg-Alw6ggtrgs7DbWij6MykIsOfpdawF4Ps5ikVe2yEHov
PERMIT
#21-EP-00570
Field Copy
Print out legibly &
in color and have
on site for inspector