HomeMy WebLinkAboutPLANS Retaining Wall 851 Dry Gulch Rd 2021-09-07PRIOR TO THE COMMENCEMENT OF ANYWORKS, THE BUILDER IS TO CHECKAND/ORDETERMINE ALL CONSTRUCTIONDETAILS, INCLUDING CHECKING EXISTINGSITE LEVELSAND DIMENSIONS. THEDRAWING IS TO BE READ INCONJUNCTION WITH ALL OTHERPROJECTDRAWINGS, CONSTRUCTION NOTESAND/OR PROJECT SPECIFICATION.ALLDISCREPANCIES SHOULD BEREPORTED IMMEDIATELY.
Notes
Drawing No.-Revision
Date
Scale
Drawn by
RevisionsDateNo.
__
Client
Job Title
Drawing Title
_
LEVEL Job #
WEST WALL REINFORCEMENT
TITLE PAGE/GENERAL NOTES
PRIOR TO THE COMMENCEMENT OF ANYWORK, THE CONTRACTOR/BUILDER IS TOCHECK AND/OR DETERMINE ALLCONSTRUCTION DETAILS, INCLUDINGCHECKING EXISTING SITE LEVELS ANDDIMENSIONS. THE DRAWING IS TO BEREAD IN CONJUNCTION WITH ALL OTHERPROJECT DRAWINGS, CONSTRUCTIONNOTES AND/OR PROJECT SPECIFICATION.ALL DISCREPANCIES SHOULD BE
REPORTED IMMEDIATELY.
Robbie Ruhaak
308 Parkview Lane
Estes Park, CO 80517
TABLE OF CONTENTS:
G1.0 TITLE PAGE AND GENERAL NOTES
S1.0 PLAN
S1.1 SECTIONS
S1.2 DETAILS
Vicinity MapN
0 6/25/2021 ISSUED FOR CONSTRUCTION
1
GENERAL STRUCTURAL NOTES
All work shall conform to the 2015 edition of the IRC/IBC as adopted by
The Town of Estes Park, CO.
STRUCTURAL ERECTION, BRACING, OBSERVATION and SHOP
DRAWINGS
·The structural drawings illustrate the completed structure with all
elements in their final positions, properly supported and braced. The
Contractor, in the proper sequence, shall provide proper shoring and
bracing as may be required to achieve the final completed structure.
·These plans have been engineered for construction at one specific
building site. Builder/contractor assumes ALL responsibility for use of
these plans at Any Other building site. Plans shall not be used for
construction at any other building site without specific review by the
engineer.
·Observations of foundation reinforcing or framing required by the
Owner, lender, insurer, building department or any other party will be
accomplished by the engineer at the Owner's expense. At least 48
hours advance notice is requested.
WOOD FRAMING:
·All framing and details not directly specified shall comply with the
prescriptive (non-engineered) requirements of the International
Residential Code.
·Sawn Lumber and Timbers:
*Except where specified on the drawings, nominal 2x, 3x, and 4x
dimension lumber shall be Douglas-Fir, Grade No. 2 except as
noted below:
*2x4 and 2x6 studs < 9'-0 in length may be Hem-Fir Stud Grade
*At contractor's option, Douglas Fir may be substituted for
Hem-Fir.
*Sill plates and ledgers in contact with concrete or masonry shall
be Hem Fir, preservative treated with zinc-borate or Southern
Yellow Pine “L3 Outdoor” lumber , or “Strandguard” LSL. ACQ
treatment is NOT acceptable.
·Wall, Floor, and Roof Framing:
*All roof rafters, joists, trusses, and beams shall be anchored to
supports with metal framing anchors.
*All wall studs shall be continuous from floor to floor or from floor
to roof.
*At built-up stud columns, nail all laminations with 16d @ 12" full
height, staggered.
·Engineered Wood:
*UNLESS OTHERWISE NOTED ON DRAWINGS, Laminated Veneer
Lumber (LVL): Manufactured 1-3/4" wide Microllams (ML) by
i-Level or equivalent with Fb=2,800 psi, E=1,900,000 psi,
Fv=285 psi.
WOOD FRAMING: HARDWARE, CONNECTORS, AND FASTENERS:
·All connectors shall meet the recommendations of the wood
manufacturer. Connectors in exposed applications shall not be less
than Hot Dipped Galvanized or Stainless Steel.
·Metal connectors shall be by Simpson Strong Tie and installed with
nailing per manufacturer's recommendations to achieve maximum
rated capacity unless noted otherwise. Note that heavy duty and
skewed hangers may require special order.
·All screws, nails, and bolts shall match material and coating of
hangers and other connectors. DO NOT mix stainless with galvanized
products.
·FASTENERS:
*Nails in roof, wall, and floor sheathing, as well as nails
designated as “8d” nails on plan, shall be 8d ring shank gun
nails (0.113” diameter x 2 ½” long) unless noted otherwise. Nail
all sheathing with 8d @ 6”/12” minimum unless noted otherwise.
*Framing nails in 2x lumber shall be 12d common nails (0.131”
diameter x 3 ¼” long) unless noted otherwise. These nails are
commonly referred to as “short sixteens” or “16d gun nails”.
Nails called out as “16d” on plan shall be 12d common nails
except as noted below or on plan:
× “16d common nails” refer to 0.162” diameter x 3 ½” long. NO
SUBSTITUTIONS.
× “16d sinker nails” refer to 0.148” diameter x 3 ¼”. NO
SUBSTITUTIONS.
× “N16” refer to .162” diameter x 2 ½” long. NO
SUBSTITUTIONS.
× Framing connector designations refer to products by Simpson
Strong-Tie Company, Inc and shall be installed as required to
develop MAX fastener capacity shown in current catalog. See
current Simpson catalog or “Installer's Pocket Guide” for
required nailing. NOTE THAT MOST HEAVY HANGERS
REQUIRE 16d COMMON NAILS. “Sinkers”, 12d common
nails, and short “hanger nails” are NOT acceptable and
WILL HAVE TO BE PULLED AND REPLACED.
× Nails designated on plan as “hanger nails” shall be 1½” 10d
(0.148” diameter x 1½” long), but DO NOT use hanger nails in
place of 16d common nails unless specifically instructed on plan.
·SDS SCREWS -1/4" screws with length indicated, per SIMPSON
STRONG TIE. NO SUBSTITUIONS.
FOUNDATION:
·Footings shall be placed on undisturbed natural soil or compacted fill
tested and approved by soils engineer.
·Foundations are designed without an engineer's soil investigation.
The foundation design criteria below were assumed for purposes of
foundation design based on the performance of the existing
structure and Presumptive Load-Bearing Values from the IBC Table
1806.2.
STRUCTURAL STEEL:
·Steel material shall be as follows unless specifically noted otherwise:
*Structural Beams.: ASTM A992
*HSS Shapes: ASTM A500 Grade B
*Anchor Bolts: ASTM A307 or A36.
*Standard pipe columns: ASTM A 53, Grade B, 35 ksi.
*Connector bolts: ASTM A307
*Plate ASTM A36
·All structural steel shall be fabricated and erected per the current
edition of AISC Steel Construction Manual.
·Welding shall be by qualified welders. Use E70XX electrodes and
3/16” fillet welds unless noted otherwise.
GENERAL CONDITIONS
·Contractor to verify that all elements coordinate with the owner,
architect, and Level's intent and notify Level Engineering LLC in
writing of any discrepancies. Use of these plans acknowledges
understanding of this.
·Any reference to architectural information on these drawings (such as
insulation, waterproofing, vapor barriers, or finish materials, truss
heel heights, plate heights) is conceptual only. Design of
architectural items is beyond the scope of Level Engineering LLC's
work.
·All shoring of existing construction is the responsibility of the
contractor. Any shoring shown on the plans is conceptual only.
LOADING CRITERIA
·ROOF DEAD LOAD = 10 PSF
·FLOOR DEAD LOAD = 15 PSF
·FLOOR LIVE LOAD = 40 PSF
·GROUND SNOW LOAD = 69 PSF
·WIND SPEED = 175 MPH, EXP C
·ELEVATION = 7817.98 FT
·SEISMIC DESIGN CATEGORY = B
SCOPE OF WORK SUMMARY
WEST WALL IN LIVING AREA IS SHOWING SIGNS OF DISTRESS IN
DRYWALL AND IS BOWING INWARD NEAR THE TOP OF THE
WINDOWS. THIS DESIGN IS TO REINFORCE THE WALL.
1 8/30/2021 REVISED NOTES
1
1
Date:
2021.09.01
15:07:55
-06'00'
Reviewed by
SAFEbuilt
09/07/2021
APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
09/07/2021
PRINT PLANS IN COLOR AND HAVE FOR
INSPECTOR AT TIME OF INSPECTION
LIVING ROOM DINING ROOM
KITCHEN
EXISTING RAFTER
SUPPORT BEAM
EXISTING RAFTER
SUPPORT BEAM
1
S1.1
PLAN
TO PREVENT EXISTING RAFTER
BEAM FROM FURTHER ROTATION,
ANCHOR BEAM TO EXISTING
MASONRY FIREPLACE WITH (2)
5/8" DIA BOLTS, EQUALLY SPACED
VERTICALLY.
32'-0" ±
PRIOR TO THE COMMENCEMENT OF ANYWORKS, THE BUILDER IS TO CHECKAND/ORDETERMINE ALL CONSTRUCTIONDETAILS, INCLUDING CHECKING EXISTINGSITE LEVELSAND DIMENSIONS. THEDRAWING IS TO BE READ INCONJUNCTION WITH ALL OTHERPROJECTDRAWINGS, CONSTRUCTION NOTESAND/OR PROJECT SPECIFICATION.ALLDISCREPANCIES SHOULD BEREPORTED IMMEDIATELY.
Notes
Drawing No.-Revision
Date
Scale
Drawn by
RevisionsDateNo.
__
Client
Job Title
Drawing Title
_
LEVEL Job #
WEST WALL REINFORCEMENT
PLAN
PRIOR TO THE COMMENCEMENT OF ANYWORK, THE CONTRACTOR/BUILDER IS TOCHECK AND/OR DETERMINE ALLCONSTRUCTION DETAILS, INCLUDINGCHECKING EXISTING SITE LEVELS ANDDIMENSIONS. THE DRAWING IS TO BEREAD IN CONJUNCTION WITH ALL OTHERPROJECT DRAWINGS, CONSTRUCTIONNOTES AND/OR PROJECT SPECIFICATION.ALL DISCREPANCIES SHOULD BE
REPORTED IMMEDIATELY.
1/4" = 1'-0"
0
0 6/25/2021 ISSUED FOR CONSTRUCTION
N
Date:
2021.09.01
15:08:18
-06'00'
Reviewed by
SAFEbuilt
09/07/2021
EXISTING
WINDOW
HEADER
EXISTING
WINDOW
HEADER
2
S1.1
EXISTING 2X4
STUDS @ 16" O.C.
EXISTING 2X8
RAFTERS @ 16" O.C.
HS
S
3
-
1
/
2
X
3
-
1
/
2
X
1
/
4
EXISTING
FOUNDATION
B
S1.2
A
S1.2
FASTEN STUD TO WINDOW HEADER
WITH SIMPSON A35 CLIP, TYP AT
EACH STUD THAT BEARS ON HEADER
C
S1.2
(2) 1/2" DIA
THRU-BOLTS
EXISTING 4X14 RAFTER
SUPPORT BEAM
CONTRACTOR TO INSPECT
EXISTING BRACES AND MAY
REUSE OR REPLACE WITH SAME
PROFILE SIZE (DF, GRADE #2 OR
BETTER). ONE BRACE ON EACH
SIDE OF RAFTER SUPPORT BEAM.
EXISTING 2X8 RAFTERS
FLASHING &
WATERPROOFING
BY CONTRACTOR
EXISTING EXTERIOR
SHEATHING
EXISTING
CONCRETE
FOUNDATION
EXISTING FLOOR
SHEATHING & 2X8
FLOOR JOISTS
INTERIOR
EXTERIOR
13'-534" ±
PRIOR TO THE COMMENCEMENT OF ANYWORKS, THE BUILDER IS TO CHECKAND/ORDETERMINE ALL CONSTRUCTIONDETAILS, INCLUDING CHECKING EXISTINGSITE LEVELSAND DIMENSIONS. THEDRAWING IS TO BE READ INCONJUNCTION WITH ALL OTHERPROJECTDRAWINGS, CONSTRUCTION NOTESAND/OR PROJECT SPECIFICATION.ALLDISCREPANCIES SHOULD BEREPORTED IMMEDIATELY.
Notes
Drawing No.-Revision
Date
Scale
Drawn by
RevisionsDateNo.
__
Client
Job Title
Drawing Title
_
LEVEL Job #
WEST WALL REINFORCEMENT
SECTIONS
PRIOR TO THE COMMENCEMENT OF ANYWORK, THE CONTRACTOR/BUILDER IS TOCHECK AND/OR DETERMINE ALLCONSTRUCTION DETAILS, INCLUDINGCHECKING EXISTING SITE LEVELS ANDDIMENSIONS. THE DRAWING IS TO BEREAD IN CONJUNCTION WITH ALL OTHERPROJECT DRAWINGS, CONSTRUCTIONNOTES AND/OR PROJECT SPECIFICATION.ALL DISCREPANCIES SHOULD BE
REPORTED IMMEDIATELY.
3/8" = 1'-0"
0
0 6/25/2021 ISSUED FOR CONSTRUCTION
S1.1
1 SECTION
S1.1
2 SECTION
Date:
2021.09.01
15:08:40
-06'00'
Reviewed by
SAFEbuilt
09/07/2021
(3) 1/2" DIA
THRU-BOLTS9"
414"
212"
214"
1/4" BENT PLATE3/16
1/4" BENT
PLATE
HSS HSS
EXISTING
RAFTER
BEAM
EXISTING
RAFTER BEAM
212"
(2) 1/2" DIA
DRILL & EPOXY
BOLTS, MIN 4"
EMBEDMENT
3"
2"
814"
414"
3/16
HSS HSS
EXISTING
FOUNDATION3/8" BENT
PLATE
L4X6X1/4 OR EQUIVALENT
BENT PLATE, 3" WIDE,
LONG LEG HORIZONTAL.
TYP BOTH SIDES OF HSS.
3/16
FASTEN TO WINDOW HEADER
W/ (2) ROWS OF LAG
SCREWS, EQUALLY SPACED.
TYP BOTH SIDES OF HSS.
PRIOR TO THE COMMENCEMENT OF ANYWORKS, THE BUILDER IS TO CHECKAND/ORDETERMINE ALL CONSTRUCTIONDETAILS, INCLUDING CHECKING EXISTINGSITE LEVELSAND DIMENSIONS. THEDRAWING IS TO BE READ INCONJUNCTION WITH ALL OTHERPROJECTDRAWINGS, CONSTRUCTION NOTESAND/OR PROJECT SPECIFICATION.ALLDISCREPANCIES SHOULD BEREPORTED IMMEDIATELY.
Notes
Drawing No.-Revision
Date
Scale
Drawn by
RevisionsDateNo.
__
Client
Job Title
Drawing Title
_
LEVEL Job #
WEST WALL REINFORCEMENT
DETAILS
PRIOR TO THE COMMENCEMENT OF ANYWORK, THE CONTRACTOR/BUILDER IS TOCHECK AND/OR DETERMINE ALLCONSTRUCTION DETAILS, INCLUDINGCHECKING EXISTING SITE LEVELS ANDDIMENSIONS. THE DRAWING IS TO BEREAD IN CONJUNCTION WITH ALL OTHERPROJECT DRAWINGS, CONSTRUCTIONNOTES AND/OR PROJECT SPECIFICATION.ALL DISCREPANCIES SHOULD BE
REPORTED IMMEDIATELY.
1" = 1'-0"
0
0 6/25/2021 ISSUED FOR CONSTRUCTION
S1.2
A DETAIL
S1.2
B DETAIL
S1.2
C DETAIL
Date:
2021.09.01
15:08:57
-06'00'
Reviewed by
SAFEbuilt
09/07/2021