HomeMy WebLinkAboutPLANS Addition 130 W Wonderview Ave 1/2 2021-11-10Generated by REScheck-Web Software
Compliance Certificate
Project Mechem Residence
Energy Code:2015 IECC
Location:Estes Park, Colorado
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:1,515 ft2
Glazing Area 16%
Climate Zone:5 (7944 HDD)
Permit Date:
Construction Site:
130.5 Wonderview Ave
Estes Park, CO 80517
Owner/Agent:Designer/Contractor:
Steve Lane
BAS1S
1692 Big Thompson Ave Unit 100
Estes Park, CO 80517
9705869140
steve@bas1s.com
Permit Number:
Compliance: Passes using UA trade-off
8.0% Better Than Code Maximum UA:288 Your UA:265
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value
Prop.
U-Factor
Req.
U-Factor
Prop.
UA
Req.
UA
Ceiling: Flat Ceiling or Scissor Truss 910 45.0 0.0 0.027 0.026 25 24
Main Floor Walls: Wood Frame, 16" o.c.1,390 21.0 0.0 0.057 0.060 66 69
Garage/Entry Door: Solid Door (under 50% glazing)20 0.080 0.320 2 6
Patio Doors: Glass Door (over 50% glazing)76 0.290 0.320 22 24
Window: Wood Frame 144 0.290 0.320 42 46
Second Floor Walls: Wood Frame, 16" o.c.864 21.0 0.0 0.057 0.060 41 43
Patio Door: Glass Door (over 50% glazing)20 0.290 0.320 6 6
Windows: Wood Frame 132 0.290 0.320 38 42
Crawl: Solid Concrete or Masonry
Wall height: 3.0'
Depth below grade: 2.5'
Insulation depth: 3.0'
620 0.0 19.0 0.045 0.055 23 28
Project Title: Mechem Residence
Data filename:Page 1 of 10
11/01/21Report date:
SAFEbuilt
APPROVED
Subject to inspection and
compliance to all relevant
Adopted Building and Municipal
codes.
Changes in Plans MUST be
approved.
D.GRAHAM
11/10/2021
I-CODES 2015
PRINT PLANS IN
COLOR AND HAVE
FOR INSPECTOR AT
TIME OF
INSPECTION
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Mechem Residence
Data filename:Page 2 of 10
11/01/21Report date:
Steve Lane, AIA 11.01.2021
REVIEWED
BY SAFEBUILT
11/10/2021
SEE ENGINEERS
NOTES FOR
FOUNDATION
INSPECTION.
REVIEWED
BY SAFEBUILT
11/10/2021
WE
S
T
5
0
F
T
EA
S
T
5
0
F
T
SOUTH 95 FT
NORTH 95 FT
NO. 5 REBAR
NO. 5 REBAR
ASPHALT DRIVEWAY
WILLOWSTONE DRIVE
DECK
DECK
SITE PLAN
130-1/2 WEST
WONDERVIEW
ESTES PARK
FILE: G:\CES_JOBS\954.007
DATE: 08/02/21BY: mst
JOB No: 954.007
1692 BIG THOMPSON AVE, SUITE 200, ESTES PARK, CO 80517
PH: (970) 586-2458 FAX: (970) 586-2459
PARCEL # 3525108004
SAFEbuilt
APPROVED
Subject to inspection and
compliance to all relevant
Adopted Building and Municipal
codes.
Changes in Plans MUST be
approved.
D.GRAHAM
11/10/2021
I-CODES 2015
PRINT PLANS IN
COLOR AND HAVE
FOR INSPECTOR AT
TIME OF
INSPECTION
REVIEWED
BY SAFEBUILT
11/10/2021
3'X3' CRAWL SPACE
ACCESS
HW
Hot Water Heater
REVIEWED
BY SAFEBUILT
11/10/2021
TEMPERED GLASS
< 2' FROM DOOR
12"
TEMPERED GLASS IN STAIRWELL
TEMPERED GLASS
IN BATHROOM
SD
SD/CO
REVIEWED
BY SAFEBUILT
11/10/2021
WINDOW TO BE TEMPERED < 2' FROM DOOR
12"
WINDOW TO BE
TEMPERD
SD
SD
SD/CO
SMOKE DETECTOR ARE TO BE IN EACH SLEEPING AREA AND OUTSIDE OF EACH
SLEEPING AREA AND WITH IN 15' OF EACH SLEEPING AREA SMOKE DETECTORS ARE
NOT TO BE WITH IN 3' OF A BATHROOM.
CARBON MONOXIDE DETECTOR ARE TO BE OUTSIDE OF SLEEPING AREA AND WITH IN
15' OF EACH SLEEPING AREA.
GUARD RAILS TO BE AT MINIMUM
HEIGHT OF 36" HIGH. OPENINGS IN
FILL IN COMPONENTS TO BE A
MAXIMUM OF 4'.
WINDOWS CLOSER THAN 24" FROM
FLOOR TO SILL AND MORE THAN 72"
FROM OPENING TO GROUND REQIRE FALL
PROTECTION FOR THE WINDOW REVIEWED
BY SAFEBUILT
11/10/2021
MINIMUM 30"
OPENING FOR
WATER CLOSETS,
15" CLEARANCE
FROM CENTER
BOTH SIDES PRESSURE TEST
REQUIRED FOR
DWV AND WATER
WINDOWS TO BE
TEMPERED
<2' FROM DOOR
WINDOW TO BE
TEMPERED <2' FROM
DOOR
3'x3' CRAWL SPACE
ACCESS
NORTH SOUTH
24'-2"
24-2"
26'-10"
24'-10"
REVIEWED
BY SAFEBUILT
11/10/2021
WINDOW TO BE
TEMPERED IN STAIRWELL
24"-10"26'-10"18'-0"
REVIEWED
BY SAFEBUILT
11/10/2021
BATHROOM WINDOW
TO BE TEMPERED
24'-2"24'-2"
REVIEWED
BY SAFEBUILT
11/10/2021
1- ALL DECK JOISTS TO BE #2 HEM-FIR @ 16" O.C. UNLESS
OTHERWISE SPECIFIED
2- ATTACH RIM JOIST TO EXISTING BUILDING WITH 2 ROWS LEDGER LOK
@ 16" OC
3- ALL STRUCTURAL BACKFILL MUST BE COMPACTED TO 95%
STANDARDPROCTOR.
4- ALL CONCRETE DESIGN IS BASED UPON "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14).
5-CONCRETE SPECIFICATIONS: Fc = 3,500 psi @ 28 DAYS WITH 6% AIR (Ø
1.5%)
6- ALL WOOD TO BE #2 HEM-FIR OR BETTER UNLESS
OTHERWISE STATED.
7- ALL PIERS TO BE 12" Ø UNLESS SPECIFIED OTHERWISE.
8- ALL ENGINEERED LUMBER TO BE INSTALLED PER MANUFACTURES
RECOMMENDATIONS.
9- ALL SIMPSON CONNECTIONS (OR APPROVED EQUIVALENT) TO BE
INSTALLED PER MANUFACTURES RECOMMENDATIONS.
10- ITEMS MARKED AS (EXISTING) WERE PREVIOUSLY CONSTRUCTED.
11- ALL WINDOW/DOOR OPENINGS TO HAVE (1) KING STUD FOR EVERY TWO
FLOOR JOIST / ROOF RAFTERS WITHIN THE SPAN OF HE HEADER AND (2)
JACKS STUDS.
GROUND SNOW LOAD = 70 PSF - (10 PSF/1000 FT) * (8000-7650
FT) = 67.0 PSF (INTERPOLATED USING ELEV = 7650 FT)
ULTIMATE WIND LOAD = 173 MPH
DECK LIVE FLOOR LOAD = 40 PSF
DECK SNOW LOAD = INTERPOLATED GROUND SNOW LOAD
ELEVATION = 7650 FT, 67.0 PSF
SOIL BEARING CAPACITY = 3,500 PSF
DECOMPOSED AND FRACTURED GRANITE BEDROCK
ALL CONSTRUCTION TO CONFORM TO TOWN OF ESTES PARK
STANDARDS AND CURRENT INTERNATIONAL RESIDENTIAL
CODE AND ALL OTHER APPLICABLE CODES.
2"X6" PRESSURE
TREATED SILL PLATE
1/2"x10" ANCHOR BOLT.
2x6 FRAMING (TYP)
SUBFLOOR
9-1/2" RFPI 40, I-JOIST @16" O.C.
(2) #4 REBAR
CONT.
#4 REBAR @ 16" O.C. HORZ.
#4 REBAR @ 48" O.C. VERT.
DRAIN TILE
#4 REBAR @ 16" O.C. HORZ.
#4 REBAR @ 48" O.C. VERT.
2"X6" PRESSURE
TREATED SILL PLATE
1/2"x10" J BOLTS @ 48" O.C.
DRAIN TILE
6x6 POST (TYP)AB66 POST BASE W/
1
2"x10" J BOLT
(2)#4 REBAR
EACHWAY
FINISHED
GRADE
8"Ø COLUMN (TYP)
UNDISTURBED SOIL
PVB6 POST BASE W/
1
2"x10" J BOLT
(2) LEDGER LOKS (TYP)
2X8 DECK JOIST
@16" OC
2X6 DECKING
4" Ø TOP & BOTTOM RAIL
2" Ø+/- LOG BALUSTERS
< 4" O.C.
MAX SPACING (TYP)36
"
M
I
N
.
SIMPSON LUS HANGER
(EACH END)
2X8 & 2X10 RIM JOIST
FINISHED
GRADE
8"Ø COLUMN (TYP)4" Ø TOP & BOTTOM
RAIL
2" Ø+/- LOG BALUSTERS < 4"
O.C. MAX SPACING (TYP)
36
"
M
I
N
.
2X8 & 2X10 RIM JOIST
2X6 KNEE BRACE
(CENTER COLUMN NORTH
DECK ONLY)
(2) 1
2" THROUGH BOLTS
(TOP & BOTTOM)
< 4" SPACE
3' MIN
H'H
10'
14'-11"
6'-7"
12'-6"
2015 CORNERSTONE ENGINEERING & SURVEYING, INC.
COPYRIGHT - ALL RIGHTS RESERVED
1692 BIG THOMPSON AVE.
SUITE 200
ESTES PARK, CO 80517
PH: (970) 586-2458
FAX: (970) 586-2459
954-007
ESTES PARK, CO 80517
130-1/2 WONDERVIEW AVENUE
Michael
Todd, P.E.
2021.11.0
3
10:51:08
-06'00'
OPEN HOLE
INSPECTION REQURED
FOR DEPTH AND SIZE
REVIEWED
BY SAFEBUILT
11/10/2021
1- ALL DECK JOISTS TO BE #2 HEM-FIR @ 16" O.C. UNLESS
OTHERWISE SPECIFIED
2- ATTACH RIM JOIST TO EXISTING BUILDING WITH 2 ROWS LEDGER LOK
@ 16" OC
3- ALL STRUCTURAL BACKFILL MUST BE COMPACTED TO 95%
STANDARD PROCTOR.
4- ALL CONCRETE DESIGN IS BASED UPON "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14).
5-CONCRETE SPECIFICATIONS: Fc = 3,500 psi @ 28 DAYS WITH 6% AIR (Ø
1.5%)
6- ALL WOOD TO BE #2 HEM-FIR OR BETTER UNLESS
OTHERWISE STATED.
7- ALL PIERS TO BE 12" Ø UNLESS SPECIFIED OTHERWISE.
8- ALL ENGINEERED LUMBER TO BE INSTALLED PER MANUFACTURES
RECOMMENDATIONS.
9- ALL SIMPSON CONNECTIONS (OR APPROVED EQUIVALENT) TO BE
INSTALLED PER MANUFACTURES RECOMMENDATIONS.
10- ITEMS MARKED AS (EXISTING) WERE PREVIOUSLY CONSTRUCTED.
11- ALL WINDOW/DOOR OPENINGS TO HAVE (1) KING STUD FOR EVERY TWO
FLOOR JOIST / ROOF RAFTERS WITHIN THE SPAN OF HE HEADER AND (2)
JACKS STUDS.
GROUND SNOW LOAD = 70 PSF - (10 PSF/1000 FT) * (8000-7650
FT) = 67.0 PSF (INTERPOLATED USING ELEV = 7650 FT)
ULTIMATE WIND LOAD = 173 MPH
DECK LIVE FLOOR LOAD = 40 PSF
DECK SNOW LOAD = INTERPOLATED GROUND SNOW LOAD
ELEVATION = 7650 FT, 67.0 PSF
SOIL BEARING CAPACITY = 3,500 PSF
DECOMPOSED AND FRACTURED GRANITE BEDROCK
ALL CONSTRUCTION TO CONFORM TO TOWN OF ESTES PARK
STANDARDS AND CURRENT INTERNATIONAL RESIDENTIAL
CODE AND ALL OTHER APPLICABLE CODES.
SCALE 1/2"=1'
LESS THAN 6" DIA.
2"x6"
1X COMPOSITE DECKING
TREAD
OPEN RISER
LESS THAN 4"
10" MIN RUN
FROM NOSE TO
NOSE
1" TOE
7-3/4" MAX. RISE
4" CONCRETE
LANDING
(4) 2X12
STRINGERS
22'4'
SIMPSON DTT2Z
& HDU2-SDS2.5
CONNECTION DETAIL
1 & 4
SHEATHING TO FULLY
OVERLAP RIM JOIST
EXPOSED EARTH TO BE COVERED WITH 6 MIL VAPOR
BARRIER PER
INSTALL A CONTINUOUSLY OPERATED MECHANICAL
EXHAUST VENTILATION AT A MINIMUM CAPACITY OF 17 CUBIC
FEET PER MINUTE.
INSTALL FLOOR GRILL (4"X10") FOR AIR PATHWAY FROM
COMMON AREA (MAIN FLOOR).
PERIMETER WALLS TO BE INSULATED WITH R19 INSULATION
FROM FLOOR TO FINISHED GRADE LEVEL AND 24"
HORIZONTAL PER N1102.2.11
2015 CORNERSTONE ENGINEERING & SURVEYING, INC.
COPYRIGHT - ALL RIGHTS RESERVED
1692 BIG THOMPSON AVE.
SUITE 200
ESTES PARK, CO 80517
PH: (970) 586-2458
FAX: (970) 586-2459
954-007
ESTES PARK, CO 80517
130-1/2 WONDERVIEW AVENUE
Michael
Todd, P.E.
2021.11.0
3
10:51:29
-06'00'
CRAWL SPACE CEILING TO BE
PROTECTED WITH 1/2 TYPE X DRYWALL
PER 302.13
STAIRS
MAX RISER 7 3/4"
MIN TREAD 10"
MAX VARIANCE 3/8"
HANDRAIL 34" TO 38"
USE PRESSURE
TREATED MATERIAL
REVIEWED
BY SAFEBUILT
11/10/2021
2015 CORNERSTONE ENGINEERING & SURVEYING, INC.
COPYRIGHT - ALL RIGHTS RESERVED
1692 BIG THOMPSON AVE.
SUITE 200
ESTES PARK, CO 80517
PH: (970) 586-2458
FAX: (970) 586-2459
954-007
ESTES PARK, CO 80517
130-1/2 WONDERVIEW AVENUE
REVIEWED
BY SAFEBUILT
11/10/2021
PRESSURE TEST REQUIRED FOR