Loading...
HomeMy WebLinkAboutPLANS New SFD 1860 Sleepy Hollw Ct 2021-08-306.00' 8 . 0 0 ' 11.00 ' 1 9 . 0 0 ' 15.00 ' 2 4 . 0 0 ' 4.00' 2 8 . 0 0 ' 24.00 ' 2 8 . 0 0 ' 4.00' 3 5 . 0 0 ' 2 . 4 % 0.2% 7900.76 7900.96 7901.00 P A T I O @ M A I N F F E OUTLINE OF RESIDENCE ON POSTS D E C K @ M A I N F F E PATIO @ LOWE R F F E PROPOSED RESIDENCE LOWER FFE=7901.00' MAIN FFE=7911.43' ALLOWABLE ROOF HEIGHT ELEVATION=7933.5' PROPOSED ROOF HEIGHT ELEVATION = 7926.8' DECK @ MAIN F F E ENTRY STAIRS TAPER WALL TO GRADE TAPER WALL TO GRADE 7 8 9 5 7 9 0 0 7 8 9 5 14.00 ' 5 . 0 0 ' 2 4 . 0 0 ' 7905 7910 7901 790 2 7903 7904 7906 7907 7908 7909 7910 7 9 0 7 79 0 8 7909 78 9 6 78 9 7 78 9 8 78 9 9 TOW=7915.6' BOW=7904.8' TOW=7904.0' BOW=7901.3' TOW=7916.1' BOW=7908.5' TOW=7917.9' BOW=7910.1' 5 . 7 % 1 2 . 0 % 12 . 0 % 12. 0 % TOW=7900.9' BOW=7895.1' TOW=7901.0' BOW=7893.0' 7 9 0 5 7 9 1 0 7 9 1 5 7 9 1 5 7 9 1 0 UPPER PARKING AREA EXTENTS OF EXISTING ROCK OUTCROPS 7+17 4 + 0 0 7 + 0 0 78 7 5 78 9 5 7900 4 . 2 % 1 2 . 0 % TOW=7903.1' BOW=7896.9' TOW=7898.2' BOW=7891.8' TOW=7901.0' BOW=7897.1' TOW=7901.0' BOW=7896.7' 7900 TOW=7896.2' BOW=7889.0' TOW=7896.8' BOW=7887.8' TOW=7899.0' BOW=7895.2' FIRE APPARATUS TURN-AROUND INSTALL WATER CISTERN WITH DRY HYDRANT CONNECTION PER NFPA 1142 CISTERN TO BE MINIMUM OF 50' FROM FRONT OF STRUCTURE (GARAGE) AND MAXIMUM OF 150' FROM REAR OF STRUCTURE TOW=7896.7' BOW=7894.8' PC: 4 + 3 1 . 9 1 PT: 3+52.44 PT: 6 + 9 3 . 4 6 PRC: 6+45.09 LOT 6 SLEEPY HOLLOW DETAILED RESIDENCE AREA SHOWN TO LEFT NEAREST HYDRANT AND WATER VALVE LOCATION APPROXIMATELY 1075' FROM RESIDENCE ALONG DRIVEWAY AND ROAD GEOLOGICAL ROCK FALL HAZARD AREA NOTE: IN ADDITION TO THE ROCKFALL HAZARD AREA SHOWN HEREON, THE ENTIRETY OF THE SUBJECT PROPERTY ALSO FALLS WITHIN THE STEEP SLOPE HAZARD AREA. 1191 WOODSTOCK DRIVE, ESTES PARK, CO 80517 www.trailridgece.com * 970-308-8221 * dbangs@trailridgece.com© 2021 DAB 10' SCALE: 1" = 10' 0 20' 3" TYPE SX HOT MIX ASPHALT 4" COMPACTED CLASS 5 ABC NATIVE SUBGRADE 30 " M I N . Ø L A R G E BO U L D E R S KE Y I N M I N . 1 8 " I N T O NA T I V E S O I L PE R P L A N NATIVE SOIL PROVIDE POSITIVE DRAINAGE AWAY FROM WALL FREE DRAINING GRANULAR MATERIAL 24"-30" TALL X 48" LONG ANGULAR STACKED ROCKS 4" PERFORATED DRAIN PIPE TO DAYLIGHT OVERALL PROPERTY MAP SCALE 1"=100' ELEC/TELE/CABLE PEDESTAL SEWER MANHOLE GENERAL NOTES 1. THIS SITE PLAN IS REPRESENTATIONAL ONLY AND IS NOT TO BE INTERPRETED AS A BOUNDARY SURVEY NOR IMPROVEMENT SURVEY. 2. ALL BEARINGS SHOWN HEREON ARE PLATTED BEARINGS FROM THE AMENDED PLAT OF SLEEPY HOLLOW SUBDIVISION. LIMITED PROPERTY MONUMENTATION WAS FOUND ON-SITE FOR THE RIGHT OF WAY FOR SLEEPY HOLLOW COURT. 3. VISIBLE SURFACE UTILITIES AND BURIED UTILITIES, PER THE FIELD, ARE SHOWN HEREON. TRAIL RIDGE CONSULTING ENGINEERS DID NOT CALL FOR UNDERGROUND UTILITY LOCATES PRIOR TO THE FIELD SURVEY AND DOES NOT WARRANT THE LOCATIONS OF THE UTILITIES AS SHOWN HEREON. THAT RESPONSIBILITY LIES WITH THE OWNER/CONTRACTOR. 4. CONTOURS SHOWN HEREON ARE AT 1FT INTERNAL AND ARE BASED UPON FIELD SURVEY DATA AND 2013 LIDAR DATA. LEGAL DESCRIPTION (PER WARRANTY DEED AT RECEPTION #20180055937) LOT 6, AMENDED PLAT OF SLEEPY HOLLOW SUBDIVISION, COUNTY OF LARIMER, STATE OF COLORADO ALSO KNOWN BY STREET AND NUMBER AS LOT 6, AMD PLAT SLEEPY HOLLOW, ESTES PARK, CO 80517 SITE PLAN YONE RESIDENCE LOT 6, AMENDED PLAT OF SLEEPY HOLLOW OWNER YONE, ROBERT/VICTORIA 1860 SLEEPY HOLLOW CT ESTES PARK, CO 80517 ENGINEER/CONTACT PERSON TRAIL RIDGE CONSULTING ENGINEERS, LLC 1191 WOODSTOCK DRIVE ESTES PARK, CO 80517 ZONING INFORMATION SUBJECT PROPERTY ZONING CLASSIFICATION: E - ESTATE SURROUNDING PROPERTY ZONING CLASSIFICATION: E - ESTATE, RE - RURAL ESTATE BUILDING SETBACK (PER ZONING) = 15' FRONT, 10' SIDE, 15' REAR 8/20/21 Reviewed by SAFEbuilt 08/30/2021 PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION Rim joist shall have an air barrier on the interior between each joist.All architectural plans, engineered foundation plans, soils reports, truss drawings, energy code report or ResCheck must be onsite for inspections. All Irrigation Sprinkler Taps Shall be Protected by an Approved Back Flow Device Ice barrier required from the lowest edges of all roof surfaces to a point not less than 24" inside the exterior wall line of the building. IRC R905.1.2 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 08/30/2021 This structure must comply with the requirements of the 2017 National Electrical Code 116.5' 65.8' 75.9' 133.4' 7+17 0+ 0 0 1+0 0 2+00 3 + 0 0 4 + 0 0 5+0 0 6 + 0 0 7 + 0 0 7835 7840 78 4 5 7 8 5 0 785 5 7860 7865 787 0 78 7 5 78 8 0 7 8 8 5 7890 78 9 5 7900 TOW=7835.0' BOW=7832.0' 1:1 1:1 1:1 1:1 16 . 0 % 16 . 0 % 12.0 % 1 2 . 0 % 7 . 5 % 4 . 2 % 3 . 7 % 12.0% 1 2 . 0 % TOW=7903.1' BOW=7896.9' TOW=7908.3' BOW=7894.2' TOW=7907.9' BOW=7892.1' TOW=7902.5' BOW=7890.0' TOW=7894.8' BOW=7887.6' TOW=7898.2' BOW=7891.8' TOW=7891.8' BOW=7887.3' TOW=7880.3' BOW=7865.1'TOW=7882.2' BOW=???'TOW=7878.3' BOW=7866.6' TOW=7875.9' BOW=7869.1' 7900 3 4" K-COPPER WATER SERVICE TO TIE INTO EXISTING VALVE LOCATED IN SLEEPY HOLLOW COURT CUL-DE-SAC NATURAL GAS SERVICE LOCATION UNKNOWN - TIE INTO MAIN IN PAVED ACCESS IF AVAILABLE OR IN SLEEPY HOLLOW COURT CUL-DE-SAC IF NECESSARY SLEEPY HOLLOW COURT FOUND ALUMINUM CAP STAMPED #29415 FOUND ALUMINUM CAP STAMPED #29415 NEW 16' DRIVEWAY (12' PAVED WIDTH W/ 2' CLEAR SHOULDERS) MINIMUM LOAD BEARING CAPACITY OF 75,000 LBS. SEE ASPHALT PAVING DETAIL EXTENTS OF EXISTING ROCK OUTCROPS TOW=7896.7' BOW=7894.8' PC: 0+60.30 PC: 1+11.95 PC: 4 + 3 1 . 9 1 PC: 4+85.18 PT: 1+00.41 PT: 3+52.44 PT: 4+77.13 PT: 6 + 9 3 . 4 6 PCC: 1+39.08 PCC: 1+79.31 PCC: 3+ 1 2 . 2 2 PRC: 2+52.81 PRC: 6+45.09 EXTENTS OF EXISTING ROCK OUTCROPS NEW DRIVEWAY PROFILE HORIZ. SCALE: 1" = 30' VERT. SCALE: 1" = 30' 7825 7830 7835 7840 7845 7850 7855 7860 7865 7870 7875 7880 7885 7890 7895 7900 7905 7910 7825 7830 7835 7840 7845 7850 7855 7860 7865 7870 7875 7880 7885 7890 7895 7900 7905 7910 0+000+501+001+502+002+503+003+504+004+505+005+506+006+507+007+17 1191 WOODSTOCK DRIVE, ESTES PARK, CO 80517 www.trailridgece.com * 970-308-8221 * dbangs@trailridgece.com© 2021 DAB ELEC/TELE/CABLE PEDESTAL WATER VALVE SEWER CLEANOUT DRIVEWAY PLAN YONE RESIDENCE SCALE: 1" = 30' 60'30'0 8/20/21 Reviewed by SAFEbuilt 08/30/2021 First Floor Plan Second Floor Plan scale 1/4"=1'-0" Rear Elevation scale 1/4"=1'-0" Right Side Elevation North Elevation Basement Plan Floor Plan Upper Floor Plan scale 1/4"=1'-0" South Elevation scale 1/4"=1'-0" East Elevation scale 1/4"=1'-0" West Elevation First Floor Framing Plan Second Floor Framing Plan Roof Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan GENERAL NOTES 1.DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS - MAY NOT BE PRINTED TO SCALE 2.ENGINEERING DRAWINGS, NOTES AND SPECIFICATIONS TAKE PRECEDENCE OVER THESE PLANS. 3.ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODE, REGARDLESS OF WHAT IS, OR IS NOT ON THIS SET OF PLANS. 4.PLANS ARE INTENDED TO CONFORM TO INTERNATIONAL RESIDENTIAL CODE 2015, DESIGNER (NAMAQUA BLUEPRINT LLC - TODD WILDERMAN) MAKES NO GUARANTEE OF COMPLIANCE AND IS NOT RESPONSIBLE FOR CONSTRUCTION COMPLIANCE OR SUPERVISION. THE CONTRACTOR IS RESPONSIBLE TO COMPLY WITH ALL APPLICABLE CODE AND MAKE ADJUSTMENTS AS NECESSARY TO MAINTAIN COMPLIANCE. USE OF THESE PLANS IMPLIES AGREEMENT WITH THIS STATEMENT. 5.DIMENSIONS ARE TO FACE OF STUD. EXTERIOR WALLS TO BE 2X6, INTERIOR 2X4 UNLESS NOTED OTHERWISE. 6. WALL BEHIND CLOTHES DRYER TO BE 2X6 7. FOUNDATION DESIGN, STRUCTURAL SPECIFICATIONS, BEAMS, CONNECTIONS, FOUNDATION DRAIN, SITE DRAINAGE, LOAD CALCULATIONS, WIND LOAD, SNOW LOAD, FLOOR AND ROOF LOAD, SOIL BEARING CAPACITY, SOIL EXPANSION ETC. TO BE PER LICENSED ENGINEER. ALL NOTATIONS AND SPECIFICATIONS ON THESE PLANS ARE FOR REFERENCE AND COMMUNICATION. ENGINEERING SPECIFICATIONS TAKE PRECEDENCE REGARDLESS OF WHAT IS OR IS NOT ON THIS SET OF PLANS. 8. WINDOWS - BRAND TO BE DETERMINED - ALL WINDOWS WITHIN 24" OF DOORS, INSTALLED AT STAIRWAYS, INSTALLED NEXT TO BATH TUBS OR IN SHOWERS, AND ANY PANE OVER 9 SQ.FT., SHALL HAVE TEMPERED GLASS. WINDOW SUPPLIER AND CONTRACTOR TO VERIFY. 9. EGRESS - WINDOWS IN BEDROOMS OR OTHER HABITABLE ROOMS, SHALL HAVE EGRESS OPENING OF A MINIMUM OF 5.7 SQ.FT., MINIMUM WIDTH OF 20", MINIMUM HEIGHT OF 24", NOT MORE THAN 44" ABOVE ADJACENT FLOOR. BASEMENT WINDOWS SHALL HAVE APPROPRIATE EGRESS WINDOW WELL AND EGRESS LADDER WHEN THE BOTTOM OF THE WINDOW WELL IS MORE THAN 44" BELOW GRADE. 10. ALL MECHANICAL AND HEATING EQUIPMENT TO BE INSTALLED PER CODE. PROVIDE APPROPRIATE EXHAUST VENT AND COMBUSTION VENTING. CONSULT CODE. SERVICE DESCRIPTION NAMAQUA BLUEPRINT LLC, WILDERMAN DESIGNS, TODD WILDERMAN (DESIGNER) PROVIDES ARCHITECTURAL DESIGN AND DRAFTING FOR ALLOWED PROJECTS PER COLORADO STATUTE. THE INTENT OF THIS SERVICE IS TO PROVIDE OVERALL CONCEPT COMMUNICATION. EXACT SPECIFICATIONS MAY VARY FROM WHAT IS ON THE PLANS AND IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND/OR CLIENT TO VERIFY AND ADJUST AS NEEDED. PROJECTS REQUIRING PROFESSIONAL ENGINEERING OR OTHER PROFESSIONAL SERVICE SHALL HAVE DRAWINGS AND SPECIFICATIONS PROVIDED BY ASSOCIATED PROFESSIONALS IN THESE FIELDS OF SERVICE. CONTRACTOR OR CLIENT SHALL COORDINATE INFORMATION AND ADJUST AS NEEDED. DESIGNER MAKES NO CLAIM OF ACCURACY OR EXACTNESS AND THE PROJECT SHALL BE ASSEMBLED ACCORDING TO ALL APPLICABLE CODE, REGARDLESS OF WHAT IS, OR IS NOT ON THIS SET OF PLANS. CLIENT UNDERSTANDS THAT THERE IS NO ARCHITECTURAL STAMP OR LICENSE ASSOCIATED WITH THESE PLANS. CLIENT AND CONTRACTOR WILL INDEMNIFY AND HOLD DESIGNER HARMLESS FROM ANY AND ALL CLAIMS AS A RESULT OF THE USE OF THESE PLANS. THESE PLANS AND THE ASSOCIATED DESIGN ARE THE PROPERTY OF THE DESIGNER AND SHALL NOT BE USED OR TRANSFERRED WITHOUT EXPRESS PERMISSION OF DESIGNER. Site Plan CLIMATE ZONE 5B (dry) FENESTRATION U-FACTOR 0.32 INSULATION VALUES CEILING MIN R-49 WALL MIN R-20 SLAB MIN R-10 to MIN 24" BELOW GRADE CODE NOTES D15D15 W16W16 W17W17W17W17 D15D15 W16W16 W06W06W05W05 D10D10 W15W15 W14W14 W13W13 W14W14 W13W13 W15W15 W11W11W11W11W11W11W11W11 W06W06W05W05 D10D10 W10W10 W15W15 W10W10 W14W14 W10W10 W14W14 W10W10 W15W15 10 12 2.5 12 2.5 12 8 12 8 12 Top of Slab -10.43' Rough Ceiling - Foundation -1.05' 112 1/2" Top of Subfloor - 1st Floor 0.00' 12 5/8" Rough Ceiling - 1st Floor 9.09' 109 1/8" Highest Ridge 21.60' 150 1/16" AA JAMES HARDI - BEADED CEDARMILL HORIZONTAL LAP SIDING - COLOR TBD BB JAMES HARDI - TRIM MATERIAL CC JAMES HARDI - SOFFIT AND FASCIA DD CONTINUOUS SOFFIT VENT EE CONTINUOUS RIDGE VENT FF 36" DECK RAILING - SPACES NOT TO EXCEED 4" GG FOOTING TO BE MIN. 30" BELOW GRADE OR PER ENGINEER HH STEP FOUNDATION PER GRADE AA AA BB CC CC DDDD EE EE EE FF FF FF GG II 40 YEAR ASPHALT SHINGLES II II JJ 40 YEAR ASPHALT SHINGLES OVER ICE AND WATER SHIELD JJJJ D15D15 W16W16 W17W17W17W17 D15D15 W16W16 W06W06W05W05 D10D10 W15W15 W14W14 W13W13 W14W14 W13W13 W15W15 W11W11W11W11W11W11W11W11 W06W06W05W05 D10D10 W10W10 W15W15 W10W10 W14W14 W10W10 W14W14 W10W10 W15W15 D07D07 W04W04 D07D07 D06D06 8 12 8 12 2.5 12 2.5 12 10 12 1 0 1 2 3 4 5 22' FF FF EE EE DD DD DD AA AA AA AA HH HHGG STEP FOUNDATION PER GRADE 40 YEAR ASPHALT SHINGLES 40 YEAR ASPHALT SHINGLES OVER ICE AND WATER SHIELDII MEAN GRADE ELEVATION MEAN ELEVATION BETWEEN HIGHEST TOP PLATE AND HIGHEST RIDGE D07D07 W04W04 D07D07 D06D06 A-1 ELEVATIONS FRONT, LEFT A-2 ELEVATIONS REAR, RIGHT A-3 BASEMENT PLAN A-4 FIRST FLOOR PLAN A-5 SECOND FLOOR PLAN A-6 SECTIONS A,B A-7 SECTIONS C,D A-8 SECTION E A-9 ELECTRICAL FLOOR PLANS SHEET INDEX Measurement of Maximum Building Height. Height means the vertical distance measured from the mean average elevation of the finished grade ((lowest point elevation + highest point elevation)/2): (1)To the highest point of the roof surface, excluding parapet, if a flat roof; (2)To the deck line of a mansard roof; (3)To the mean height level between the lowest point of the topmost top plate and highest ridge for a gable, hip or gambrel roof; or (4)Exception: For any building with a steep sloped roof, the highest-point elevation shall be measured from average finished grade to the highest point on the highest ridge. For purposes of this subsection, the term "steep sloped" shall mean any roof with a pitch greater than or equal to a 12:12 ratio. Estes Valley Development Code Chapter 1, Section 1.9 E (Rules of Measurement) PROJECT PROJECT INFORMATION CODES BUILDING INFORMATION OCCUPANCY GROUP:IRC/SFD CONSTRCTION TYPE:V-B NS STORIES:1.5 HEIGHT:22' AREA CALCULATIONS 1ST FLOOR 1895 S.F. LOFT 189 S.F. GARAGE LEVEL 1513 S.F. BEDROOMS: 3 2015 INTERNATIONAL RESIDENTIAL CODE, W/ ESTES PARK,CO AMENDMENTS CONTRACTOR: TBD ENGINEER: TRAIL RIDGE CONSULTING ENGINEERS 970-308-8221 DBANGS@TRAILRIDGECE.COM ARCHITECTURAL: WILDERMAN DESIGNS LLC 303-591-3536 DESIGNSTUDIO7@COMCAST.NET SINGLE FAMILY DWELLING 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-1 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com scale 1/4"=1'-0" Front Elevation scale 1/4"=1'-0" Left Side Elevation Construction Plans 5-4-21 Reviewed by SAFEbuilt 08/30/2021 scale 1/4"=1'-0" Front Elevation First Floor Plan Second Floor Plan scale 1/4"=1'-0" Left Side Elevation North Elevation Basement Plan Main Floor Plan scale 1/4"=1'-0" South Elevation scale 1/4"=1'-0" East Elevation scale 1/4"=1'-0" West Elevation First Floor Framing Plan Second Floor Framing Plan Roof Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan Lower Floor Plan D18D18 W12W12 W19W19 W08W08 W18W18 D17D17 D18D18 W12W12 W19W19 W18W18 D12D12 W03W03 D12D12 W03W03 10 12 8 12 8 12 Top of Slab -10.18' Rough Ceiling - Foundation -1.05' 109 1/2" Top of Subfloor - 1st Floor 0.00' 12 5/8" Rough Ceiling - 1st Floor 9.09' 109 1/8" Top of Subfloor - 2nd Floor 10.15' 12 5/8" Top of Slab -10.43' Rough Ceiling - Foundation -1.05' 112 1/2" Top of Subfloor - 1st Floor 0.00' 12 5/8" Rough Ceiling - 1st Floor 9.09' 109 1/8" Top of Subfloor - 2nd Floor 10.15' 12 5/8" Highest Ridge 21.60' 137 7/16" JAMES HARDI - BEADED CEDARMILL HORIZONTAL LAP SIDING - COLOR TBD JAMES HARDI - TRIM MATERIAL JAMES HARDI - SOFFIT AND FASCIA CONTINUOUS SOFFIT VENT CONTINUOUS RIDGE VENT 36" DECK RAILING - SPACES NOT TO EXCEED 4" FOOTING TO BE MIN. 30" BELOW GRADE OR PER ENGINEER STEP FOUNDATION PER GRADE 40 YEAR ASPHALT SHINGLES 40 YEAR ASPHALT SHINGLES OVER ICE AND WATER SHIELD II II JJ FF AA AA AA EE EE EE DD DD CC BB BB D18D18 W12W12 W19W19 W08W08 W18W18 D17D17 D18D18 W12W12 W19W19 W18W18 D12D12 W03W03 D12D12 W03W03 W09W09 W07W07 W09W09 W20W20 D16D16 D19D19D19D19 W20W20 D16D16 10 12 8 12 2.5 12 Top of Slab -10.43' Rough Ceiling - Foundation -1.05' 112 1/2" Top of Subfloor - 1st Floor 0.00' 12 5/8" Rough Ceiling - 1st Floor 9.09' 109 1/8" AA JAMES HARDI - BEADED CEDARMILL HORIZONTAL LAP SIDING - COLOR TBD BB JAMES HARDI - TRIM MATERIAL CC JAMES HARDI - SOFFIT AND FASCIA DD CONTINUOUS SOFFIT VENT EE CONTINUOUS RIDGE VENT FF 36" DECK RAILING - SPACES NOT TO EXCEED 4" GG FOOTING TO BE MIN. 30" BELOW GRADE OR PER ENGINEER HH STEP FOUNDATION PER GRADE II 40 YEAR ASPHALT SHINGLES JJ 40 YEAR ASPHALT SHINGLES OVER ICE AND WATER SHIELD FF FF AA CC II HH GG W09W09 W07W07 W09W09 W20W20 D16D16 D19D19D19D19 W20W20 D16D16 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-2 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com scale 1/4"=1'-0" Rear Elevation scale 1/4"=1'-0" Right Side Elevation Construction Plans 5-4-21 Reviewed by SAFEbuilt 08/30/2021 scale 1/4"=1'-0" Front Elevation First Floor Plan Second Floor Plan scale 1/4"=1'-0" Rear Elevation scale 1/4"=1'-0" Right Side Elevation scale 1/4"=1'-0" Left Side Elevation North Elevation scale 1/4"=1'-0" Basement Plan Floor Plan Main Floor Plan Upper Floor Plan scale 1/4"=1'-0" South Elevation scale 1/4"=1'-0" East Elevation scale 1/4"=1'-0" West Elevation First Floor Framing Plan Second Floor Framing Plan Roof Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan D08D08 D07D07 D09D09 W11W11W11W11W11W11W11W11 D19D19 D19D19 W17W17W17W17 UP 11-7/8" Joists 11-7/8" Joists 11-7/8" Joists 11-7/8" Joists 2x10 Joists 2x10 Joists 2x10 Joists 2x10 Joists 11-7/8" Joists Steel-I Beam dropped 8X Beam 8X Beam 8X Beam 8X Beam 8x16 Beam 8x16 Beam 8x16 Beam 8x16 Beam 8x16 Beam 8X Beam 8X Beam 8X Beam 8x8 Post8x8 Post 8x8 Post 8x8 Post 8x8 Post 8x8 Post8x8 Post 8x8 Post 8x8 Post 8x8 Post 8x8 Post 8x8 Post 8x8 Post 3-1/2" STEEL COLUMN 3-1/2" STEEL COLUMN 3-1/2" STEEL COLUMN 3-1/2" STEEL COLUMN 8x8 Post 10x10 Post C CCC Section C E4E4 Exterior Elevation Right A A A A Section A B B B B Section B DD Section D E E E E Section E 19'-5" 3'-4" 5'-6"7'-8"5'-10"3'-9"5'-6"5'-6"5'-6"3'-9" 19'24'28' 71' 6' 11' 15' 32' 3'-10" 11'-2" 15' 20'-2"7'-10"8"23'-4"11'8' 71' 2' 9' 2' 9' 2' 4' 24' 4' 1' 11' 11' 1' 7'-3 3/4"12'-0 1/16"11'-8 3/16"11'-8 1/4"10'-2"18'-1 3/4" 8' 1'-4" 11'-4" 1'-4" 4' 1'-0 1/2" 3'-3" 6'-1 1/2" 3" 13'-4" 23'-5 1/4"4'-4 1/2"6'-3 5/8"17'-6 5/8" 7' 6'-1 1/2" 7'-6" 10' 16' 2' 4' 4'-3 3/4" 2'-11 3/4" 5'-8 1/2" 9'-8" 1'-4" 5'-9 3/8" 2'-10 7/8" 4'-3 3/4" 12'12'17'-1" 8'-11 15/16" 12' 79 sq ft 38 sq ft 1218 sq ft 55 sq ft 113 sq ft Garage Crawl Space Slab On Grade Mechanical 8x8 ANGLE BRACE8x8 ANGLE BRACE 8x8 ANGLE BRACE8x8 ANGLE BRACE8x8 ANGLE BRACE ENTIRE GARAGE WALLS AND CEILING TO BE 5/8" TYPE X GYP Stair FIRE DOOR W/ CLOSER 5/8" TYPE X GYP WALLS AND CEILING F.D. GAS FURNACE HWT PROVIDE VENTILATION W/ MECHANCIAL SYSTEM 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-3 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com Construction Plans 5-4-212015 IECC sec. R402.4.4 Appliances must be direct vent (combustion and exhaust) or the mechanical equipment must be located within a room entirely isolated from the rest of the building's thermal envelope in accordance with sec. R402.4.4 Reviewed by SAFEbuilt 08/30/2021 Basement Plan Main Floor Plan Upper Floor Plan First Floor Plan Floor Plan First Floor Framing Plan Second Floor Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan Roof Framing Plan scale 1/4"=1'-0" Floor Plan DN LCB36RDWSB36B39B15R 2DB2712 2DB27 2DB27 2DB3612 B36 SB2422R SB4222 SB4222 SB24R B21R B2422R 2DB2712 LCB36RDWSB36B39B15R 2DB2712 2DB27 2DB27 2DB3612 B36 SB2422R SB4222 SB4222 SB24R B21R B2422R 2DB2712 U3024108 U1824108R W2436R W2436R W5436 W394124 W2454R W2454L W2454R W2454R W242417 W242417 D03D03 D12D12 D18D18 W12W12 W20W20 D16D16 W06W06W05W05W01W01 D10D10 W07W07W09W09 W10W10 W15W15 W10W10 W14W14 W13W13 W10W10 W14W14 W13W13 W10W10 W15W15 D06D06 D15D15 W16W16 W03W03 3068 D01D01 D05D05 D11D11 W04W04 D04D04 D20D20 W19W19 W08W08 W18W18 6068 D02D02 D22D22 D14D14 D13D13 2668 D21D21 UP ATTIC ACCESS 22x30 ATTIC ACCESS 22x30 8x Beam 10x18 Beam 6x8 Beam 6x8 Beam 6x8 Beam 6x8 Beam 8x Beam 8x Beam 6x8 Beam 6x8 Beam 6x8 Beam 6x8 Beam 6x8 Beam 8x8 Post 10x10 Post 8x8 Post 8x8 Post 8x8 Post C CCC Section C E3E3 Exterior Elevation Back Exterior Elevation Right A A A A Section A B B B B Section B D DDD Section D E E E E Section E 24'24'28' 76' 28'24'11'8'5' 76' 6' 24' 4' 8' 14' 6' 1' 14'1'16'1'3' 1' 6' 4' 10'-6" 13'-6" 5'-10" 4'-10" 6'-10" 6'-6" 5'-8 1/2"5'-3 1/2"6'-6"11'-3"6'-3"4'-0 1/2"3'-9 1/2"2'-10 1/2"2'-7"4'-3"10'-5 1/2" 7'-10"5'-5 1/2"14'-8 1/2" 10'-8" 4'-1" 9'-3" 8'-3 1/2"3'-10"1'-7 1/2"5'-6 11/16"5'-2 13/16"3'-11" 5'-5" 5'3'3'-1"3'-6"4'-5" 7' 4'-2 1/2" 2'-9 1/2" 1'-6" 6'-6"4'-8" 4'-0 1/2" 2'-5" 10'-10 1/2" 12'6'-7 1/2"5'-4 1/2" 6'-2"5'-10"6'-1"5'-11"3'-9"5'-6"5'-6"5'-6"3'-9"2'-8"2'-8"6'-3 1/2"2'-6 1/2"11'-3"2'-7"5' 12'46'-2"17'-10" 2'-8 5/16" 2'-11 9/16" 1/2" 7'-3 5/8" 3'-6" 12'-0 1/2" 19' 3'-9" 4'-4" 2'-1" 9'-3" 4'-1" 7'-10" 9'-11" 10'-8" 13'-4" 52 sq ft 196 sq ft 10 sq ft9 sq ft 76 sq ft 127 sq ft 70 sq ft 15 sq ft 19 sq ft 425 sq ft 50 sq ft 150 sq ft 116 sq ft 24 sq ft 329 sq ft 56 sq ft 56 sq ft 47 sq ft 181 sq ft 125 sq ft 152 sq ft 66 sq ft 56 sq ft 12 sq ft 66 sq ft Living Area Stairwell Bedroom 2 Bedroom 3 Bath Hall Shower Master BathCloset Master Bdrm Entry Hall Laundry Pantry Deck Deck Dog Room Slab Deck Broom Deck Dining Kitchen Living ClosetCloset SPIRAL STAIR UP CONC FLOOR CHANNEL DRAIN DOG DOOR OPTIONAL 4:12 VAULTED CEILINGGAS FIREPLACE 2-STORY VAULTED CEILING 9' CEILING 9' CEILING 9' CEILING9' CEILING 9' CEILING 9' CEILING 9' CEILING 9' CEILING 9' CEILING 9' CEILING RAILING 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-4 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com Construction Plans 5-4-21 MAINTAIN 6' 6" HEADROOM Reviewed by SAFEbuilt 08/30/2021 Basement Plan Main Floor Plan Upper Floor Plan Second Floor Plan First Floor Plan Floor Plan First Floor Framing Plan Second Floor Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan Roof Framing Plan scale 1/4"=1'-0" Second Floor Plan D17D17 2 1/2 : 12 10 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 10 : 12 2 1/2 : 12 2 1/2 : 12 Trusses Trusses Trusses Rafters Rafters 10x Beam 10x10 Post C CCC Section C E3E3 Exterior Elevation Back Exterior Elevation Right A A A A Section A B B B B Section B D DDD Section D E E E E Section E 6'12'6' 24' 19' 15' 34' 7' 6'6' 6'12'6' 24' 15' 19' 34' 3'18'3' 6'6'6'6' 19' 7' 173 sq ft 189 sq ft 73 sq ft 73 sq ft 425 sq ft 125 sq ft Living Area Deck Open Below Loft AtticAttic ATTIC ACCESS 22x30 ATTIC ACCESS 22x30 DOOR SCHEDULE NUMBER ROOM NAME LABEL QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTION COMMENTS D01 HALL/BATH 2468 1 1 2468 L IN 28 3/16 "80 "HINGED-DOOR P01 D02 HALL/BROOM 2468 1 1 2468 R IN 28 "80 "HINGED-DOOR P01 D03 DINING/DOG ROOM 2668 1 1 2668 L EX 30 "80 "EXT. HINGED-DOOR E21 D04 MASTER BDRM/MASTER BATH 2668 1 1 2668 R 30 "80 "BARN-DOOR P01 D05 BEDROOM 2/HALL 2668 1 1 2668 R IN 30 "80 "HINGED-DOOR P01 D06 LIVING/DECK 2680 1 1 2680 R EX 30 "96 "EXT. HINGED-GLASS PANEL D07 GARAGE 3068 1 0 3068 L EX 36 "80 "EXT. HINGED-DOOR E21 D08 MECHANICAL/GARAGE 3068 1 0 3068 L IN 36 "80 "HINGED-SLAB D09 STAIR/GARAGE 3068 1 0 3068 R IN 36 "80 "HINGED-SLAB D10 ENTRY/DECK 3068 1 1 3068 L EX 36 "80 "EXT. HINGED-DOOR E21 D11 MASTER BDRM/HALL 3068 1 1 3068 L IN 36 "80 "HINGED-DOOR P01 D12 DOG ROOM 3068 1 1 3068 R EX 36 "80 "EXT. HINGED-DOOR E21 D13 LAUNDRY/HALL 3068 1 1 3068 R IN 36 "80 "HINGED-DOOR P01 D14 BEDROOM 2/CLOSET 4068 1 1 4068 R IN 48 "80 "SLIDER-PANEL D15 BEDROOM 3/DECK 6068 1 1 6068 L EX 72 "80 "EXT. SLIDER-GLASS PANEL D16 MASTER BDRM/DECK 6068 1 1 6068 R EX 72 "80 "EXT. SLIDER-GLASS PANEL D17 LOFT/DECK 6068 1 2 6068 R EX 72 "80 "EXT. SLIDER-GLASS PANEL D18 DINING/SLAB 8080 1 1 8080 R EX 96 "96 "EXT. SLIDER-GLASS PANEL D19 GARAGE 9080 2 0 9080 108 "96 "GARAGE-GARAGE DOOR CHD10 D20 BEDROOM 3/HALL 2668 1 1 2668 R IN 30 "80 "HINGED-DOOR P01 D21 BEDROOM 3/CLOSET 4068 1 1 4068 R IN 48 "80 "SLIDER-PANEL D22 HALL/PANTRY 2468 1 1 2468 R IN 28 "80 "HINGED-DOOR P01 WINDOW SCHEDULE NUMBER LABEL ROOM NAME QTY FLOOR SIZE WIDTH HEIGHT EGRESS TEMPERED DESCRIPTION COMMENTS AREA, ACTUAL (SQ FT) W01 2640SC LAUNDRY/DECK 1 1 2640SC 30 "48 "YES SINGLE CASEMENT-HL 10.0 W03 2640SC BATH 1 1 2640SC 30 "48 "SINGLE CASEMENT-HR 10.0 W04 2640SC BEDROOM 2 1 1 2640SC 30 "48 "YES SINGLE CASEMENT-HR 10.0 W05 2650SC MASTER BDRM 1 1 2650SC 30 "60 "YES SINGLE CASEMENT-HL 12.5 W06 2650SC MASTER BDRM 1 1 2650SC 30 "60 "YES SINGLE CASEMENT-HR 12.5 W07 3016FX LIVING/DECK 1 1 3016FX 36 "18 "FIXED GLASS 4.5 W08 3020FX CLOSET 1 1 3020FX 36 "24 "FIXED GLASS 6.0 W09 3050SC LIVING/DECK 1 1 3050SC 36 "60 "SINGLE CASEMENT-HR 15.0 W10 4016AW LIVING/DECK 4 1 4016AW 48 "18 "SINGLE AWNING 6.0 W11 4030FX GARAGE 4 0 4030FX 48 "36 "FIXED GLASS 12.0 W12 8440TC KITCHEN/SLAB 1 1 8440TC 100 "48 "TRIPLE CASEMENT-LHL/RHR 33.33 W13 4057FX LIVING/DECK 2 1 4057FX 48 "67 "FIXED GLASS 15.67 W14 4070FX LIVING/DECK 2 1 4070FX 48 "84 "FIXED GLASS 28.0 W15 4091FX LIVING/DECK 2 1 4091FX 48 "109 "FIXED GLASS 29.67 W16 5040DC BEDROOM 2 1 1 5040DC 60 "48 "YES DOUBLE CASEMENT-LHL/RHR 20.0 W17 5040LS GARAGE 2 0 5040LS 60 "48 "LEFT SLIDING 20.0 W18 5050FX MASTER BATH 1 1 5050FX 60 "60 "YES FIXED GLASS 25.0 W19 5060FX STAIRWELL 1 1 5060FX 60 "72 "YES FIXED GLASS 30.0 W20 2640SC MASTER BATH 1 1 2640SC 30 "48 "SINGLE CASEMENT-HR 10.0 TOTALS:457.51 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-5 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com VERIFY EGRESS AND TEMPERING REQUIREMENTS Construction Plans 5-4-21 PROVIDE ENGINEERED TRUSS LAYOUT AND PRODUCT SPECS ON SITE FOR THE INSPECTOR Reviewed by SAFEbuilt 08/30/2021 Basement Plan Main Floor Plan Upper Floor Plan Second Floor Plan First Floor Plan Floor Plan First Floor Framing Plan Second Floor Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan Roof Framing Plan 4 12 8 12 Top of Slab -10.43' Rough Ceiling - Foundation -1.05' 112 1/2" Top of Subfloor - 1st Floor 0.00' 12 5/8" Rough Ceiling - 1st Floor 9.09' 109 1/8" Ridge 17.83' 104 13/16" 5/8" TYPE X GYP R-30 BATTS R-23 BLOWN F.G.R-19 BATTS R-23 BLOWN F.G. R-23 BLOWN F.G. R-49 BLOWN F.G. Garage Master Bedroom Master Bath Attic D01D01D05D05 8 12 2.5 12 2.5 12 Top of Subfloor - 1st Floor -0.50' Top of Subfloor - 1st Floor 0.00'6" Rough Ceiling - 1st Floor 8.09' 97 1/8" Garage Bedroom 2 Attic Hall Broom Dog Room CONC FLOOR W/ CHANNEL DRAIN TRUSSES 2x6 RAFTERS TRUSSES R-30 BATTS HARDI SOFFIT MATERIAL D01D01D05D05 Garage/House (2)2x6 Top Plate 2x6 Studs @ 16" o.c. 2x6 Bottom Plate 1/2" Gypsum Board5/8" Type X Gypsum Board GARAGE INTERIOR R-23 Blown Fiberglass Insulation scale 1"=1' Typ Interior 2x6 (2)2x6 Top Plate 2x6 Studs @ 16" o.c. 2x6 Bottom Plate 1/2" Gypsum Board 1/2" Gypsum Board scale 1"=1' (2)2x4 Top Plate 2x4 Studs @ 16" o.c. 2x4 Bottom Plate 1/2" Gypsum Board1/2" Gypsum Board Typ Interior 2x4 scale 1"=1' GARAGE EXTERIORINTERIOR Eave Detail scale 1"=1' TRUSSES 1/2" OSB SHEATHING 40 YEAR ASPHALT SHINGLES OVER 30# FELT DRIP EDGE FLASHING GUTTER 8" HARDI FASCIA T&G SOFFIT W/ CONTINUOUS VENT 5/8" GYP TRUSS CLIP DOUBLE 2x6 PLATE 2x6 STUDS @ 16" O.C. W/ R-23 BLOWN FIBERGLASS 1/2" GYP R-49 BLOWN FIBERGLASS 2x6 SUB-FASCIA VENT BAFFLES Typical Basement scale 1"=1' 8" CONCRETE FOUNDATION REBAR PER ENGINEER FOOTING DRAIN FOOTING SEAL COATING 2x6 STUDS @ 16" O.C. W/ R-23 BLOWN FIBERGLASS (TYP) 7/16" ZIP SYSTEM SHEATHING PANEL W/ SEAM TAPE TREATED 2x6 SILL W/ SILL SEAL W/ 1/2"x10" CAST-IN-PLACE ANCHOR BOLTS JOISTS PER ENG.RIM JOIST 3/4" T&G DECKING BASEBOARD FLOOR FINISH SIDING PER ELEVATION BOTTOM PLATE (2)2x4 TOP PLATE 1/2" GYP 2x4 STUDS @ 16" O.C. W/ R-19 BATTS TREATED BOTTOM PLATE 1/2" EXPANSION JOINT 4" CONCRETE FLOOR 1/2" AIR GAP FLOOR/WALL EXTERIORINTERIOR scale 1"=1' 2x6 PLATE 3/4" T&G DECKING GLUE & NAIL FLOOR FINISH (2) 2x6 PLATE RIM BOARD FLOOR JOISTS 2x6 STUDS 2x6 STUDS 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-6 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com scale 3/8"=1'-0" Section Detail A scale 3/8"=1'-0" Section Detail B Construction Plans 5-4-21 PROVIDE ENGINEERED TRUSS LAYOUT AND PRODUCT SPECS ON SITE FOR THE INSPECTOR Reviewed by SAFEbuilt 08/30/2021 D18D18 D12D12 D18D18D18D18 W12W12 D17D17 D18D18 W12W12 10 12 Rough Ceiling - Foundation -1.05' Top of Subfloor - 1st Floor 0.00' 12 5/8" Rough Ceiling - 1st Floor 8.09' 97 1/8" Rough Ceiling - Foundation -1.05' Top of Subfloor - 1st Floor 0.00' 12 5/8" Rough Ceiling - 1st Floor 9.09' 109 1/8" Top of Subfloor - 2nd Floor 10.15' 12 5/8" Highest Ridge 21.60' 137 7/16" 6'12'6' 5'-1 3/16" 2'-4 7/8" LoftAttic Attic Dining Kitchen Crawl Space Dog Room D18D18 D12D12 D18D18D18D18 W12W12 D17D17 D18D18 W12W12 Basement Plan Main Floor Plan Upper Floor Plan Second Floor Plan First Floor Plan Floor Plan First Floor Framing Plan Second Floor Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan Roof Framing Plan W11W11W11W11 W17W17W17W17 D15D15 W16W16 W11W11W11W11 W17W17W17W17 W11W11W11W11W11W11 W05W05 W01W01 D10D10 W11W11W11W11W11W11 W06W06 10'-7 1/2" Loft Dining Kitchen VERIFY W/ TRUSSES W11W11W11W11 W17W17W17W17 D15D15 W16W16 W11W11W11W11 W17W17W17W17 W11W11W11W11W11W11 W05W05 W01W01 D10D10 W11W11W11W11W11W11 W06W06 Typical Foundation scale 1"=1' 8" CONCRETE FOUNDATION REBAR PER ENGINEER FOOTING DRAIN FOOTING SEAL COATING 2x6 STUDS @ 16" O.C. W/ R-23 BLOWN FIBERGLASS (TYP) 7/16" ZIP SYSTEM SHEATHING PANEL W/ SEAM TAPE TREATED 2x6 SILL W/ SILL SEAL W/ 1/2"x10" CAST-IN-PLACE ANCHOR BOLTS JOISTS PER ENG.RIM JOIST 3/4" T&G DECKING BASEBOARD FLOOR FINISH SIDING PER ELEVATION R-19 VINYL FACED BASEMENT DRAPE POLY VAPOR BARRIER BOTTOM PLATE 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-7 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com scale 3/8"=1'-0" Section Detail C scale 1/4"=1'-0" Section Detail D Construction Plans 5-4-21 Reviewed by SAFEbuilt 08/30/2021 Basement Plan Main Floor Plan Upper Floor Plan Second Floor Plan First Floor Plan Floor Plan First Floor Framing Plan Second Floor Framing Plan Roof Plan Main Floor Framing Plan Upper Floor Framing Plan Roof Framing Plan 7 3/8" 10 1/2" 10'-6" 10'-4 1/2" VERIFY ALL DIMENSIONS IN THE FIELD AND ADJUST AS NEEDED TO MAINTAIN CODE COMPLIANCE SEE IRC 2015 SECTION R311.7 STAIRWAYS WIDTH - STAIRWAY SHALL BE NOT LESS THAN 36" WIDE - HANDRAILS SHALL NOT PROJECT MORE THAN 4-1/2" ON EITHER SIDE OF THE STAIRWAY AND THE CLEAR WIDTH OF THE STAIRWAY AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31-1/2" HEADROOM - MINIMUM HEADROOM REQUIRED 6'-8" MEASURED FROM SLOPE OF STAIR NOSING TO FINISHED SURFACE DIRECTLY ABOVE VERTICAL RISE - VERTICAL RISE SHALL NOT EXCEED 147" BETWEEN FLOORS AND LANDINGS RISERS - RISERS SHALL NOT EXCEED 7-3/4" AND SHALL NOT VARY MORE THAN 3/8" BETWEEN THE TALLEST AND THE SHORTEST RISER WITHIN A SET OF STAIRS TREADS - TREAD DEPTH SHALL NOT BE LESS THAN 10" AND THE WIDEST AND THE NARROWEST TREAD WITHIN A SET OF STAIRS SHALL NOT VARY MY MORE THAN 3/8" LANDINGS - THERE SHALL BE A LANDING AT THE TOP AND THE BOTTOM OF THE STAIR THAT MUST BE AT LEAST AS WIDE AS THE STAIR AND BE NO LESS THAN 36" IN THE DIRECTION OF TRAVEL HANDRAILS - A 1-1/2" GRIP SIZE HANDRAIL SHALL BE PROVIDED 34" TO 38" ABOVE THE LINE OF TREAD NOSING AND BE CONTINUOUS FOR THE ENTIRETY OF THE SECTION OF STAIR RAILINGS - RAILINGS OR GUARDS SHALL BE PROVIDED AT OPEN SIDE OF STAIR PER SECTION R312 THIS NOTE SHOWS ONLY THE GENERAL REQUIREMENTS FOR THIS SECTION - REFER TO IRC 2015 SECTION R311.7 FOR COMPLETE INFORMATION 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-8 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com scale 1/2"=1'-0" Section Detail E Construction Plans 5-4-21 Reviewed by SAFEbuilt 08/30/2021 Basement Plan Main Floor Plan Upper Floor Plan Second Floor Plan First Floor Plan Floor Plan First Floor Framing Plan Second Floor Framing Plan UP OPENER OPENER TV TV CO/SD CO/SD 3 3 WP 3 3 3 3 WP DN UP TV TV TVTV CO/SD CO/SD SD SD SD R R R R R R RRR R GFCI R R WP WP WP 3 3 3 3 3 33 3 3 3 3 3 3 3 3 3 3 3 3 4 3 4 4 RR GFCI GFCI 3 R R WP3 TV CO/SD WP 3 3 scale 1/4"=1'-0" Basement Electrical Plan scale 1/4"=1'-0" 1st Floor Electrical Plan WP R 4 GFCI 3WP SD T TV DESCRIPTIONSYMBOL ELECTRICAL - DATA - AUDIO LEGEND Ceiling Fan Ventilation Fans: Ceiling Mounted, Wall Mounted Ceiling Mounted Light Fixtures, Recessed Can Light Wall Mounted Light Fixtures: Flush Mounted, Wall Sconce 240V Receptacle 110V Receptacles: Duplex, Weather Proof, GFCI Switches: Single Pole, Weather Proof, 3-Way, 4-Way Wall Jacks: TV/Cable Telephone Jack Thermostat Door Chime, Door Bell Button Smoke Detectors: Ceiling Mounted, Wall Mounted Smoke/CO Detectors: Ceiling Mounted, Wall MountedCO/SD Exterior light sources shall be concealed or shielded with luminaires with cut-offs with an angle not exceeding ninety (90) degrees to minimize the potential for glare and unnecessary diffusion on adjacent property. In no case shall exterior lighting add more than one (1) foot-candle to illumination levels at any point off site. DARK SKY LIGHTING 5/4/2021 Contractor Lot 6, Sleepy Hollow Subdivision Estes Park Colorado A-9 Robert & Vickie Yone SHEET NUMBER Revision DATE Mike Primeau 720-276-9774 primeau@comcast.net Copyright Protected © 2021 Contractor Phil McLain 970-412-7471 Phil@McLainbuilt.com scale 1/4"=1'-0" 2nd Floor Electrical Plan ELECTRICAL, DATA, & AUDIO NOTES: HOME OWNER SHALL DO A WALK-THRU WITH RELEVANT INSTALLERS TO VERIFY THE EXACT LOCATION FOR OUTLETS, LIGHTS, SWITCHES, CABLE, DATA, PHONE, AUDIO, ETC. ELECTRICAL NOTES: 1.ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE G.F.I. ORG.F.I.C. PER NATIONAL ELECTRICAL CODE REQUIREMENTS. 2.PROVIDE ONE SMOKE DETECTOR IN EACH ROOM AND ONE IN EACH CORRIDOR ACCESSING BEDROOMS. CONNECT SMOKE DETECTORS TO HOUSE POWER AND INTER-CONNECT SMOKE DETECTORS SO THAT, WHEN ANY ONE IS TRIPPED, THEY ALL WILL SOUND. PROVIDE BATTERY BACKUP FOR ALL UNITS. 3.CIRCUITS SHALL BE VERIFIED WITH HOME OWNER PRIOR TO WIRE INSTALLATION. 4.FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED WITH HOME OWNER. 5.FIXTURES TO BE SELECTED BY HOME OWNER. Construction Plans 5-4-21 Reviewed by SAFEbuilt 08/30/2021 DESIGN LOADS CODE: 2015 IRC W/ToEP LOCAL AMENDMENTS ELEV - 7888 FEET GROUND SNOW LOAD: 60 PSF @ 7000 FT, 70 PSF @ 8000 FT INTERPOLATED GROUND SNOW LOAD: 69 PSF ROOFS: ROOF DEAD LOAD: 15 PSF SLOPED ROOF SNOW LOAD Pg: 53 PSF FLOORS: FLOOR LIVE LOAD: 40 PSF FLOOR DEAD LOAD: 10 PSF DECK LIVE LOAD: 69 PSF DECK DEAD LOAD: 10 PSF WIND: ULTIMATE WIND SPEED: 175 MPH, EXP. C SEISMIC: DESIGN CATEGORY B ASSUMED SOIL BEARING CAPACITY: 2500 PSF (ENGINEER TO VERIFY) GENERAL NOTES 1. REFERENCES TO "ENGINEER" ON THE DRAWINGS REFERS TO THE STRUCTURAL ENGINEER OF RECORD. 2. LOCATE ALL UNDERGROUND UTILITIES AND NOTIFY ENGINEER OF EXISTING UTILITIES THAT CONFLICT OR INTERFERE WITH WORK. 3. DO NOT SCALE DRAWINGS. CONTACT DESIGNER FOR CLARIFICATION OF DIMENSIONING AND ANNOTATE ON THE RECORD DRAWINGS ANY MISSING DIMENSIONS. 4. DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. 5. DETAILS NOTED AS TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE. 6. THE STRUCTURE IS DESIGNED TO FUNCTION AS A COMPLETE UNIT. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S METHODS AND SEQUENCING OF CONSTRUCTION. 7. USE ONLY HAND OPERATED TOOLS FOR COMPACTION ADJACENT TO FOUNDATION WALLS AND STEM WALLS. EXCAVATION 1. EXCAVATE SOIL TO ACCOMMODATE NEW FOOTINGS TO DEPTHS AS SHOWN ON THE DRAWINGS. HAND TRIM ALL EXCAVATIONS AS REQUIRED AND REMOVE LOOSE/SOFT MATERIALS. 2. FOOTINGS HAVE BEEN DESIGNED FOR AN ASSUMED ALLOWABLE SOIL BEARING PRESSURE OF 2,500 PSF. 3. PROTECT THE SITE AND ALL CONSTRUCTION, EXISTING AND PROPOSED, FROM THE EFFECTS OF FREEZING OR FROST ACTION. 4. PLACE AND COMPACT BACKFILL IN EQUAL CONTINUOUS LAYERS NOT EXCEEDING 9" OF COMPACTED DEPTH FOR HAND HELD COMPACTION EQUIPMENT AND A MAXIMUM OF 12" INCHES COMPACTED DEPTH FOR VIBRATORY ROLLERS. 5. MAINTAIN OPTIMUM MOISTURE CONTENT OF BACKFILL MATERIALS TO ATTAIN COMPACTION DENSITY. 6. BACKFILL SIMULTANEOUSLY ON EACH SIDE OF FOUNDATION WALLS THAT ARE NOT DESIGNED FOR RETAINING SOIL ON ONE SIDE. 7. IMPORTED GRANULAR BACKFILL TO MEET THE FOLLOWING CRITERIA: SIEVE DESIGNATION % BY WEIGHT PASSING SIEVES 3 INCH 100 NO. 4 45-75 NO. 100 0-12 NO. 200 0-6 8. SUITABLE NATIVE SOIL: ON SITE SAND OR GRAVEL REASONABLY FREE OF LOAM, SILT, CLAY, OR ORGANIC MATTER. CAST-IN-PLACE CONCRETE 1. ALL WORK SHALL COMPLY WITH ACI 301-10, UNLESS NOTED OTHERWISE IN DRAWINGS OR SPECIFICATIONS. 2. DETAIL BARS IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS AND ACI PUBLICATION SP-66 (2004): "ACI DETAILING MANUAL". 3. REINFORCING MATERIALS: TYP REINFORCING - ASTM A615, Fy=60 KSI, Fu=90 KSI WELDED AND FIELD BENT REINF - ASTM A706, Fy=60 SKI, Fu=90 KSI WELDED WIRE REINFORCING, SMOOTH - ASTM A1064, Fy=65 KSI, Fu=75 KSI WELDED WIRE REINFORCING, DEFORMED - ASTM A1064, Fy=70 KSI, Fu=80 KSI EPOXY COATED REINFORCING - ASTM A775 OR ASTM A934 3. REINFORCING FABRICATION: a. NO SPLICING OF REINFORCEMENT PERMITTED EXCEPT AS NOTED ON THE DRAWINGS. MAKE BARS CONTINUOUS AROUND CORNERS WHERE DETAILS ARE NOT PROVIDED. WHERE PERMITTED, MAKE SPLICES WITH CONTACT LAPS OR MECHANICAL CONNECTORS. b. PROVIDE ADDITIONAL BARS/STIRRUPS REQUIRED TO SECURE REINFORCING IN PLACE DURING CONCRETE PLACEMENT. c. MAKE ALL REINFORCING BAR BENDS IN THE FABRICATOR'S SHOP. d. NO WELDING OF REINFORCING IS PERMITTED UNLESS NOTED ON THE DRAWINGS. 4. CONCRETE MIX REQUIREMENTS: a. MIX TYPE 1- FOOTINGS, PILASTERS, STEM WALLS, BASEMENT WALLS NOT EXPOSED TO FREEZING OR MOISTURE -28 DAY COMPRESSIVE STRENGTH, f'c=3000 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM AGGREGATE SIZE = 1" b. MIX TYPE 2- FOOTINGS, PILASTERS, STEM WALLS, BASEMENT WALLS EXPOSED TO FREEZING OR MOISTURE -28 DAY COMPRESSIVE STRENGTH. f'c=4500 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM W/C RATIO 0.45 -MAXIMUM AGGREGATE SIZE = 3 4" -TOTAL AIR CONTENT 5% c. MIX TYPE 3- ALL CONCRETE EXPOSED TO WEATHER OR DEICER, BEAMS, SLABS AND WALLS -28 DAY COMPRESSIVE STRENGTH, f'c=5000 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM W/C RATIO 0.4 -MAXIMUM AGGREGATE SIZE = 3 4" -TOTAL AIR CONTENT 6% d. MIX TYPE 4- INTERIOR TOPPING SLABS AND SLABS ON DECK -28 DAY COMPRESSIVE STRENGTH, f'c=3500 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM W/C RATIO 0.5 -MAXIMUM AGGREGATE SIZE = 3 4" -ADDITION OF ENTRAINED AIR NOT PERMITTED e. MIX TYPE 5- INTERIOR SLAB ON GRADE -28 DAY COMPRESSIVE STRENGTH, f'c=3500 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM AGGREGATE SIZE = 1" -ADDITION OF ENTRAINED AIR NOT PERMITTED 3. PROPORTIONS OF MATERIALS IN CONCRETE MIX SHALL BE ESTABLISHED TO PROVIDE THE MINIMUM COMPRESSIVE STRENGTH REQUIRED AND PROVIDE WORKABILITY AND CONSISTENCY TO PERMIT CONCRETE TO BE WORKED READILY INTO FORMS AND AROUND REINFORCEMENT WITHOUT SEGREGATION OR EXCESSIVE BLEEDING. USE ADMIXTURES AS REQUIRED TO OBTAIN DESIRED RESULTS. DO NOT EXCEED THE MAXIMUM WATER-CEMENT RATIO. 4. USE PORTLAND TYPE I/II CEMENT UNLESS OTHERWISE NOTED. FOR CONCRETE MIXES USED ON FLOORS MINIMUM CEMENTITIOUS CONTENT SHALL BE 540 POUNDS PER CUBIC YARD. 5. AGGREGATE TO BE PER ASTM C33. 3 4" AGGREGATE TO MEET SIZE #67 AGGREGATE, 1" AGGREGATE TO MEET SIZE #57 AGGREGATE. 6. PLACE NO CONCRETE WHEN AMBIENT TEMPERATURE IS BELOW 40 DEGREES FAHRENHEIT OR MORE THAN 90 DEGREES FAHRENHEIT UNLESS PLACEMENT PROCEDURE IS IN COMPLIANCE WITH ACI 305 OR ACI 306. 7. COMPLY WITH ACI CODES AND PLACE CONCRETE IN A CONTINUOUS OPERATION WITHIN PLANNED JOINTS OR SECTIONS. DO NOT PERMIT COLD JOINTS TO OCCUR. 8. GROUT: PRE-MIXED, NON-SHRINK, WITH MINIMUM COMPRESSIVE STRENGTH OF 6000 PSI AT 28 DAYS. 9. NO CONCRETE SHALL BE DROPPED MORE THAN 4 FEET INSIDE A FORM. 10. CONCRETE FORMS SHALL BE CLEAN AND FREE FROM DEBRIS. IF FORMS ARE COATED WITH A RELEASE AGENT, THE RELEASE AGENT SHALL BE COLORLESS MINERAL OIL WHICH SHALL NOT STAIN CONCRETE OR ABSORB MOISTURE OR IMPAIR NATURAL BONDING OF CONCRETE. 11. CONTRACTOR IS RESPONSIBLE FOR ALL FORM DESIGN/BRACING REQUIREMENTS. 12. UNLESS OTHERWISE NOTED, CENTER ALL FOUNDATION PIERS AND FOOTINGS ON COLUMN CENTERLINES. 13. CHAIRS AND SPACERS SHALL BE PLACED TO ADEQUATELY SUPPORT REINFORCING DURING PLACEMENT. FOREIGN MATERIALS SUCH AS WOOD OR OTHER UNSUITABLE SUPPORTS SHALL NOT BE USED TO SUPPORT REINFORCING. SET WIRE TIES SO ENDS ARE DIRECTED INTO CONCRETE WHERE CONCRETE WILL BE EXPOSED. 14. CONCRETE CLEAR COVER FOR REINFORCEMENT (UNLESS SHOWN OTHERWISE): a. BOTTOM OF FOOTINGS AND SLABS ON GRADE: 3". b. FOUNDATION WALLS AND EXTERIOR WALLS: 2". c. TOP AND BOTTOM OF ELEVATED SLABS: 3/4". d. ALL FACES OF PIERS: 1-1/2". 15. FOOTINGS a. SIZE AND DEPTH AS INDICATED ON THE DRAWINGS. b. MINIMUM FROST PROTECTION DEPTH TO BE 30". 16. WALLS a. WALL THICKNESS TO BE 8" OR AS NOTED ON THE DRAWINGS. b. VERTICAL STEEL TO HOOK INTO FOOTING AS NOTED ON THE DRAWINGS. c. VERTICAL STEEL TO EXTEND ABOVE FOOTING MINIMUM OF 24", UNLESS NOTED OTHERWISE, FOR SPLICE ABOVE. d. 1 2" ANCHOR BOLTS FOR SILL PLATES SHALL BE IMBEDDED 7" MINIMUM AND SHALL BE PLACED A MINIMUM OF 48" O.C. AND WITHIN 12" OF EACH END OF ALL SILL PLATES. d. ANCHOR BOLTS TO HAVE MINIMUM 3 16"x2"x2" WASHER. WOOD FRAMING AND SHEATHING 1. IN-GRADE BASE VALUES HAVE BEEN USED FOR THIS DESIGN. 2. 2x FRAMING SHALL BE HEM-FIR #2 AND BETTER UNLESS OTHERWISE NOTED. 3. ALL LUMBER SHALL BE 19% MAXIMUM MOISTURE CONTENT. 4. SOLID TIMBER BEAMS AND POSTS SHALL BE DOUGLAS FIR-LARCH #1 OR BETTER UNLESS OTHERWISE NOTED. 5. WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 6. PRESERVATIVE TREATED WOOD SHALL BE TREATED IN ACCORDANCE WITH AWPA U1 AND AEPA M4. 7. LVL FRAMING SHALL BE LAMINATED DOUGLAS FIR OR SOUTHERN PINE (GP LAM BY GEORGIA PACIFIC OR MICROLAM BY TRUS-JOIST OR EQUIVALENT) MEETING THE FOLLOWING MINIMUM ALLOWABLE STRESS CRITERIA: FB (BENDING STRESS) = 2600 PSI FV (HORIZ. SHEAR STRESS) = 285 PSI E (MODULUS OF ELASTICITY) = 1,900,000 PSI FC (COMPRESSION PERPENDICULAR TO GRAIN) = 750 PSI 8. I-JOISTS SHALL BE AS NOTED ON THE STRUCTURAL DRAWINGS AND MEET THE PROVISIONS OF ASTM D5055. 9. PROVIDE SOLID BLOCKING BETWEEN JOISTS UNDER JAMB STUDS OF OPENINGS. 10. COLUMNS MUST HAVE A CONTINUOUS LOAD PATH TO THE FOUNDATION. 11. UNLESS OTHERWISE INDICATED, INSTALL TWO LENGTHS OF SOLID BLOCKING x JOIST DEPTH x 12 INCHES LONG IN THE FLOOR FRAMING UNDER COLUMN LOADS. 12. ALL BEAMS AND TRUSSES SHALL BE BRACED AGAINST ROTATION AT POINTS OF BEARING. 13. UNLESS NOTED ON THE DRAWINGS, LOWER CHORD OF GABLE END TRUSSES SHALL BE ANCHORED TO WALL PLATE WITH FRAMING ANCHORS AT 4' SPACING AND LATERALLY BRACED TO ROOF FRAMING AT 8' SPACING. 14. MINIMUM NAILING SHALL BE AS SPECIFIED IN IBC TABLE 2304.9.1 "FASTENING SCHEDULE". 15. METAL FRAMING ANCHORS SHOWN OR REQUIRED SHALL BE SIMPSON STRONG TIE OR EQUAL CODE APPROVED CONNECTORS AND INSTALLED WITH THE NUMBER AND TYPE OF NAILS RECOMMENDED BY THE MANUFACTURER TO ACHEIVE THE RATED CAPACITY. HEAVY-DUTY AND SKEWED HANGERS MAY REQUIRE SPECIAL ORDER AND NOT STOCKED LOCALLY. 16. ALL RAFTERS, JOISTS, TRUSSES AND BEAMS SHALL BE ANCHORED TO SUPPORTS WITH METAL FRAMING ANCHORS. 17. LEAD HOLES FOR LAG SCREWS SHALL BE 40%-70% OF THE SHANK DIAMETER OF THE THREADED SECTION AND EQUAL TO THE SHANK DIAMETER AT THE UNTHREADED SECTION. 18. CONNECTOR BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME B18.2.1 AND ASTM SAE J429 GRADE 1. NAILS AND SPIKES SHALL CONFORM TO ASTM F1667. 19. WOOD SCREWS SHALL CONFORM TO ANSI/ASME B18.6.1. 20. ROOF, FLOOR AND WALL SHEATHING: APA RATED OR ADVANTECH VIP+ SHEATHING, THICKNESS AS INDICATED, SPAN RATING AS REQUIRED TO SUIT SUPPORT SPACING INDICATED, EXPOSURE DURABILITY 1, THREE SPAN MINIMUM. 21. SUB-FLOOR GLUE: APA AFG-01, WATERPROOF OF WATER SOLVENT BASE, AIR CURE TYPE, CARTRIDGE DISPENSED. 22. MINIMUM FLOOR SHEATHING - 23/32" APA STURD-I-FLOOR RATED 24" O.C. TONGUE AND GROOVE, GLUED AND NAILED. 23. MINIMUM ROOF SHEATHING - 5/8" OSB OR CDX PLYWOOD, APA 40/20, NAILED. 24. MINIMUM EXTERIOR WALL SHEATHING - 7/16" OSB OR CDX PLYWOOD, APA 24/16, BLOCKED AS NOTED AND NAILED. 25. MINIMUM INTERIOR WALL SHEATHING - 1/2" GYPSUM BOARD, ASTM C 1396/C 1396M 26. WALL SHEATHING TO BE NAILED WITH 8d COMMON NAILS OR 10d BOX NAILS AT 6" O.C. AT PANEL EDGES AND 12" O.C. AT INTERMEDIATE FRAMING EXCEPT AS NOTED. NAIL ALL PLATES USING THE EDGE NAILING NOTED. 27. SHEATHE ALL EXTERIOR WALLS. SHEATHE INTERIOR WALLS AS NOTED ON ARCHITECTURAL DRAWINGS. 28. SHEATHING SHALL BE CONTINUOUS FROM TOP PLATE TO BOTTOM PLATE. CUT IN "L" AND "T" SHAPES AROUND OPENINGS. 29. LAP SHEATHING OVER RIM JOISTS A MINIMUM OF 4" AT ALL FLOORS TO TIE UPPER AND LOWER WALL STUDS TOGETHER. INSTALL METAL STRAPS AS INDICATED ON THE BRACED WALL DRAWINGS. 30. MINIMUM HEIGHT OF SHEATHING PANELS TO BE 16" TO ENSURE THAT PLATES ARE TIED TO STUDS. 31. MAKE PROVISIONS FOR ERECTION LOADS, AND FOR SUFFICIENT TEMPORARY BRACING TO MAINTAIN STRUCTURE SAFE, PLUMB, AND IN TRUE ALIGNMENT UNTIL COMPLETION OF ERECTION AND INSTALLATION OF PERMANENT BRACING. 32. SECURE ROOF SHEATHING WITH LONGER EDGE PERPENDICULAR TO FRAMING MEMBERS AND WITH ENDS STAGGERED AND SHEET ENDS OVER BEARING. 33. WHERE TONGUE AND GROOVE PLYWOOD IS USED, FULLY ENGAGE TONGUE AND GROOVE EDGES. 34. SECURE SUB-FLOOR SHEATHING WITH LONGER EDGE PERPENDICULAR TO FLOOR FRAMING AND WITH END JOINTS STAGGERED AND SHEET ENDS OVER BEARING. ATTACH WITH SUB-FLOOR GLUE AND DRYWALL SCREWS. 35. RIM BOARD SHALL BE 1 ¼" LSL ATTACHED TO I-JOISTS WITH 10D NAILS - ONE INTO EACH FLANGE. RIM BOARD SHALL BE TOE NAILED TO PLATE WITH 10D NAILS AT 6 INCHES ON CENTER. I JOISTS SHALL BE ATTACHED TO PLATE WITH 8D NAILS DRIVEN AT AN ANGLE INTO BOTTOM FLANGE - ONE ON EACH SIDE OF WEB AT LEAST 1 ½ INCHES FROM END. 36. FLOOR SHEATHING SHALL BE ATTACHED TO JOISTS WITH 8D NAILS AT 6 INCHES ON CENTER EDGES AND 12 INCHES ON CENTER FIELD. TOE PLATE OF WALL FRAMING TO BE ATTACHED TO RIM BOARD WITH 16D NAILS AT 4-INCHES ON CENTER. EXTERIOR STUDS TO BE 2X6 AND TO BE END NAILED TO SILL AND TOP PLATE WITH A MINIMUM OF (2) 16D NAILS. ALL DOUBLE TOP PLATE SPLICES IN EXTERIOR WALLS TO LAP 6 FEET WITH 18 10D NAILS EACH SIDE OF SPLICE. FLOOR SHEATHING TO BE 3 4" OSB TONGUE AND GROOVE. 37. FOR WINDOW AND DOOR HEADERS, THE NUMBERS OF FULL HEIGHT STUDS, JACK STUDS (TRIMMERS) AND HEADER UPLIFT ATTACHMENTS SHALL BE PER THE TABLE ON THIS SHEET. HEADER SIZES SHALL BE AS NOTED ON THE STRUCTURAL DRAWINGS. 38. SPECIAL NAILING REQUIREMENTS: a. ROOF SHEATHING -ALL NAILS TO BE 8d COMMON OR 10d BOX. -SHEATHING TO BE NAILED WITHIN 4 FEET OF THE PERIMETER AND RIDGE OF THE ROOF 3" O.C. EDGE AND FIELD. -ALL OTHER PANELS NAILED 6" O.C. EDGE, 12" O.C. FIELD. b. INTERIOR GYPSUM WALL BOARD -GYPSUM BOARD TO BE MIN 1/2" THICK. -MAXIMUM STUD SPACING 16" O.C. UNLESS NOTED OTHERWISE. -PANELS TO BE FASTENED 7" O.C. EDGE AND 10" O.C. FIELD. -FASTENERS TO BE 1 1/4" NO. 6 TYPE S OR W DRYWALL SCREWS, 5d COOLER NAILS. -FASTENERS TO BE SPACED NO LESS THAN 3/8" FROM EDGES AND ENDS OF GYPSUM BOARDS. -FOUR FOOT WIDE PIECES OF SHEATHING SHALL BE APPLIED PARALLEL OR PERPENDICULAR TO STUDS. -TWO FOOT WIDE PIECES SHALL BE APPLIED PERPENDICULAR TO STUDS. -STAGGER END JOINTS OF ADJACENT COURSES OF GYPSUM BOARD SUCH THAT THEY DONT OCCUR OVER SAME STUD. c. CONTINUOUS EXTERIOR WOOD STRUCTURAL PANEL -PANELS UP TO 1/2" SHALL BE NAILED W/8d COMMON NAILS 6" O.C. EDGE, 12" O.C. FIELD. -PANELS OVER 1/2" THICK SHALL BE NAILED W/8d NAILS 6" O.C. EDGE, 12" O.C. FIELD. -BLOCKING OF PANEL EDGES SHALL BE INSTALLED AS NOTED ON THE BRACED WALL DRAWINGS. 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 2 0 DA B TYPICAL DETAILS/CONSTRUCTION SCHEDULES 6/14/21 STRUCTURAL STEEL NOTES 1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" (AISC 360) AND THE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" (AISC 303) BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). 2. STRUCTURAL STEEL WIDE FLANGE BEAMS AND WTs SHALL CONFORM TO ASTM A992, 50 KSI YIELD. 3. ROLLED STEEL FLOOR PLATES SHALL CONFORM TO ASTM A786-05, COMMERCIAL GRADE. 4. OTHER ROLLED SHAPES, INCLUDING PLATES, CHANNELS, WTs AND ANGLES SHALL CONFORM TO ASTM A36, 36 KSI YIELD. 5. HOLLOW STRUCTURAL STEEL SECTIONS (HSS) RECTANGULAR SHAPES SHALL CONFORM TO ASTM A500, GRADE B, 46 KSI YIELD. 6. HSS ROUND SHAPES SHALL CONFORM TO ASTM A500, GRADE B, 42 KSI YEILD. 7. PIPE SHAPES SHALL CONFORM TO ASTM A53-12, GRADE B, 35 KSI YIELD. 8. EXCEPT AS NOTED, FRAMED BEAM CONNECTIONS SHALL BE BEARING-TYPE WITH 3/4" DIAMETER, SNUG TIGHT, ASTM A325-04 BOLTS, DETAILED IN CONFORMANCE WITH THE STRUCTURAL DRAWINGS AND THE "STEEL CONSTRUCTION MANUAL" BY THE AISC, 13TH EDITION. INSTALL BOLTS IN ACCORDANCE WITH AISC'S "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS," 2010. 9. ALL BEAMS SHALL HAVE FULL DEPTH WEB STIFFENERS EACH SIDE OF WEBS ABOVE AND BELOW COLUMNS. 10. ANCHOR RODS SHALL CONFORM TO ASTM F1554-99, GRADE (36, 55, AND/OR 105) AS NOTED ON THE STRUCTURAL DRAWINGS WITH WELDABILITY SUPPLEMENT S1. 11. WELDING SHALL BE DONE BY A CERTIFIED WELDER IN ACCORDANCE WITH THE AISC DOCUMENTS LISTED ABOVE, THE AMERICAN WELDING SOCIETY (AWS) D1.1: 2010 STRUCTURAL WELDING CODE, AND THE RECOMMENDATIONS FOR USE OF WELD E70 ELECTRODES. WHERE NOT SPECIFICALLY NOTED, MINIMUM WELD SHALL BE 3/16" FILLET BY LENGTH OF CONTACT EDGE. 12. ALL POST-INSTALLED ANCHORS SHALL HAVE CURRENT INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORTS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 15. EXPANSION ANCHORS SHALL BE APPROVED "WEDGE" TYPE UNLESS SPECIFICALLY NOTED TO BE "SLEEVE" TYPE AS NOTED ON THE STRUCTURAL DRAWINGS. 16. POST INSTALLED BOLTS AND REBAR SHALL USE AN APPROVED EPOXY OR SIMILAR ADHESIVE TYPE AS APPROPRIATE FOR INSTALLATION IN SOLID AND NON-SOLID BASE MATERIALS. 17. GROUT BENEATH COLUMN BASE AND BEAM BEARING PLATES SHALL HAVE A MINIMUM 28-DAY, COMPRESSIVE STRENGTH OF 7,500 PSI AND SHALL BE NON-SHRINK, NON-METALLIC, AND TESTED IN ACCORDANCE WITH ASTM C1107-13. 18. WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE AWS. QUALIFICATION TESTS. 19. MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN 3/16”h FILLET, CONTINUOUS UNLESS OTHERWISE NOTED. 20. WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED. INCREASE WELD SIZE IF GAPS EXIST AT THE FAYING SURFACE. 21. WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY ANSI/AISC 360-05 TABLES J2.3 AND J2.4. 22. ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED. OPEN-WEB WOOD TRUSS NOTES 1. MANUFACTURE AND INSTALLATION OF METAL PLATED WOOD TRUSSES SHALL COMPLY WITH ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL-PLATE-CONNECTED WOOD TRUSS CONSTRUCTION," BCSI-2008 (BUILDING COMPONENT SAFETY INFORMATION) "GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING & BRACING OF METAL PLATE CONNECTED WOOD TRUSSES," AND DSB-89 "RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING OF METAL PLATE CONNECTED WOOD TRUSSES." 2. PRE-ENGINEERED, PREFABRICATED TRUSSES SHALL BE DESIGNED BY AN ENGINEER REGISTERED IN THE STATE OF COLORADO, AND SHALL COMPLY WITH CODE REQUIREMENTS. 3. TRUSSES SHALL BE DESIGNED TO SUPPORT THE FULL DEAD LOADS AND THE SUPERIMPOSED DESIGN LOADS NOTED ABOVE OR ON THE DRAWINGS. 4. STRESSES SHALL NOT EXCEED THOSE LISTED IN THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH 2005 SUPPLEMENT (AF&PA NDS-2005). <NO INCREASES IN STRESS ARE ALLOWED FOR DURATION OF LOAD.> 5. THE FABRICATOR SHALL DETERMINE TRUSS WEB ARRANGEMENTS AND MEMBER FORCES. 6. TRUSS TO TRUSS CONNECTIONS SPECIFIED SHALL BE BY TRUSS SUPPLIER, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. 7. UNLESS OTHERWISE INDICATED, TRUSSES SHALL BE DESIGNED FOR PERPENDICULAR TO GRAIN BEARING ON HEM FIR PLATES (405 PSI). END GRAIN BEARING IS NOT ALLOWED UNLESS ACCEPTED IN WRITING BY ENGINEER. DESIGN TRUSS FOR BEARING BLOCKS OR TRUSS BEARING ENHANCERS AS REQUIRED TO COMPENSATE FOR OVERSTRESSES. SPECIFY SIZE, SPECIES, AND NAILING FOR BEARING BLOCKS. 8. TRUSS FABRICATOR SHALL SPECIFY ALL FLOOR AND ROOF TRUSS BRACING AND BRIDGING. CALCULATIONS AND SHOP DRAWINGS, INCLUDING MEMBER SIZES, LUMBER SPECIES AND GRADES, AND SUBSTANTIATING DATA FOR CONNECTOR CAPACITIES, SHALL BE SUBMITTED TO THE ENGINEER/LOCAL ENTITY BUILDING OFFICIAL FOR REVIEW PRIOR TO FRAMING INSPECTION. Reviewed by SAFEbuilt 08/30/2021 24' 28' F36 24'11'8' 4' 15' 11' 6' 4" CONCRETE SLAB W/6x6 W1.4xW1.4 WWF CENTERED 4" CONCRETE SLAB W/6x6 W1.4xW1.4 WWF CENTERED CRAWL SPACE 19'24'28' F36 F36 F24 F24 F24F24 F24 F16A F16A F16A F16A F16A 9'-101 4" 3'-53 8" 33 4"11'-81 4"11'-81 4"33 4" 11'-81 4" 12'11'-81 4" 9'-41 4" 1'-41 4" 4'-81 4" 1'-93 8" 2'-107 8" F12 F12 1'-83 8" 2'-117 8" 1' 11' 11' 1' 5'-83 8" 4'-33 4"15'-41 2"4'-33 4" 4' 4" 11'-4"5'-105 8"6'-35 8"4'-41 2"3'-43 4"19'-41 2" 11'-4" 10' 8'-37 8"9'-4" 4" F1 6 F1 6 F1 6 F1 6 F1 6 F1 6 F1 6 F1 6 F16 F16 F16 F16 F16 F48 F48 12" SONOTUBE W/(3) #4 BARS VERT W/4" HOOKS TYP OF 3 HD1 HD1 HD1 HD1 HD1 HD1 HD1 HD1 HD1 HD1 HD1 6" MIN 10'-6" MAX 48" 12" #5 VERT @ 15" O.C. W/6" HOOK 30" MIN SPLICE LENGTH (4) #4 CONT. #4 @ 12" HORIZ. FOUNDATION DRAIN AND BEDDING FLOOR FRAMING WALL FRAMING 8" WALL 12" 2'-4" 6" MIN 30" MIN 8" WALL 16" 8" #4 VERT @ SPACING PER NOTES ON SHEET S1 W/4" HOOK (2) #4 CONT. #4 @ 16" HORIZ. FOUNDATION DRAIN AND BEDDING FLOOR FRAMING WALL FRAMING 6" MIN 30" MIN 8" WALL 16" 8" #4 VERT @ SPACING PER NOTES ON SHEET S1 W/4" HOOK (2) #4 CONT. #4 @ 16" HORIZ. FOUNDATION DRAIN AND BEDDING REINFORCED SLAB WALL FRAMING F16AF16AF16AF16AF16A F16A 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 2 0 DA B FOUNDATION NOTES: 1. CONCRETE WALL/FOOTING CONSTRUCTION TO BE INSTALLED PER GENERAL NOTES ON SHEET. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONING, FOUNDATION ELEVATIONS AND EXTERIOR GRADES PRIOR TO FORMING AND POURING CONCRETE FOOTINGS. CONTACT ENGINEER WITH ANY KNOWN DISCREPANCIES. 3. FOUNDATION DIMENSIONS SHOWN ARE TO CENTER OF PAD FOOTING OR EXTERIOR CORNER WALL UNLESS NOTED OTHERWISE. 4. ALL FOOTINGS TO BEAR ON UNDISTURBED NATIVE SOILS OR APPROVED, COMPACTED STRUCTURAL FILL. COMPACTION TESTING TO VERIFY COMPACTION OF STRUCTURAL FILLS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ENGINEER TO PERFORM OPEN HOLE INSPECTION TO VERIFY ASSUMED SOIL BEARING CAPACITY PRIOR TO FORMING CONCRETE. 5. CONTRACTOR MAY ALTER FOUNDATION FOOTING ELEVATIONS AND WALL HEIGHTS BASED UPON FIELD CONDITIONS. CONTACT DESIGN ENGINEER FOR APPROVAL IF WALL HEIGHTS INCREASE ABOVE WHAT IS SHOWN HEREON. 6. FOUNDATION DESIGN ASSUMES NO HYDROSTATIC PRESSURE ON CONCRETE WALLS. CONTRACTOR TO INSTALL FOUNDATION FOOTING DRAIN AT BOTTOM OF FOOTING ELEVATION WITH A MINIMUM OF 4" PERFORATED DRAIN PIPE BACKFILLED IN A 24" BED OF 1.5" WASHED ROCK. CONCRETE WALLS TO BE BACKFILLED WITH FREE DRAINING GRANULAR SOILS. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION ELEMENTS FOR ALL SURFACE FLOWS. 0'4'8'2'16' FOUNDATION PLAN 6/14/21 SCALE: NTS STANDARD RETAINING WALL DETAIL HOLD-DOWN SCHEDULE: HD1 - SIMPSON STHD14/STHD14-RJ AS APPLICABLE POST BASE SCHEDULE: 8x8 - SIMPSON ABU88Z 10x10 - SIMPSON ABU1010Z SCALE: NTS STANDARD FROST WALL DETAIL Reviewed by SAFEbuilt 08/30/2021 FLOOR FRAMING NOTES: 1. SOLID BLOCKING FOR ALL REPETITIVE FRAMING MEMBERS TO BE PROVIDED AT ALL BEARING POINTS. 2. BEARING SURFACES FOR ALL BEAMS TO BE STUD PACKS WITH A MINIMUM WIDTH OF THE MEMBER BEING SUPPORTED UNLESS NOTED OTHERWISE. 3. GENERAL NAILING AND FRAMING REQUIREMENTS FOR FLOOR FRAMING TO BE PER THE GENERAL NOTES ON SHEET S1. 4. TYPICAL FLOOR ASSEMBLY INCLUDES 11 7 8" I-JOISTS, 3 4" PLYWOOD AND FINISH PER ARCHITECTURAL DRAWINGS. 5. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONING OF FLOOR FRAMING. 6. EXTERIOR LUMBER TO BE EXTERIOR GRADE (PRESSURE TREATED) OR PROTECTED FROM ELEMENTS PER 2015 IRC REQUIREMENTS. 7. ALL HEADERS NOT SPECIFICALLY NOTED TO BE (2) 2x10. 8x8 POST W/SIMPSON CBT4Z BEAM TIE 11 7 8" R F P I 4 0 @ 1 6 " O . C . W10x30 DROPPED STEEL BEAM 11 7 8" R F P I 4 0 @ 1 6 " O . C . 11 7 8" R F P I 4 0 @ 1 6 " O . C . 11 7 8" R F P I 4 0 @ 1 6 " O . C . 11 7 8" R F P I 4 0 @ 1 6 " O . C . 2x 1 0 @ 1 6 " O . C . 2x10 @ 12" O.C.2x10 @ 12" O.C.2x10 @ 12" O.C.2x10 @ 12" O.C. 8x12 DF#1 DROPPED BEAM 8x12 DF#1 DROPPED BEAM 8x 1 0 D F # 1 D R O P P E D B E A M 8x 1 0 D F # 1 D R O P P E D B E A M 8x 1 0 D F # 1 D R O P P E D B E A M 8x 1 0 D F # 1 D R O P P E D B E A M 8x 1 0 D F # 1 D R O P P E D B E A M 8x8 DF#1 DROPPED BEAM 8x8 DF#1 DROPPED BEAM DE C O R A T I V E T I M B E R B E A M DECORATIVE TIMBER BEAM 13 4"x117 8" LVL FLUSH BEAM 3"∅ PRE-MANUFACTURED STEEL POST 3"∅ PRE-MANUFACTURED STEEL POST 3"∅ PRE-MANUFACTURED STEEL POST 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST FROM ROOF ABOVE 8x8 POST FROM ROOF ABOVE 10x10 POST FROM ROOF ABOVE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 13 4"x117 8" LVL FLUSH BEAM 2x 6 @ 16 " O . C . 2x12 STRINGERS 2x12 STRINGERS (2) 13 4"x91 2" LVL HEADER(2) 13 4"x91 2" LVL HEADER (3 ) 1 3 4"x 9 1 2" L V L H E A D E R (3 ) 1 3 4"x 9 1 2" L V L H E A D E R (3 ) 1 3 4"x 1 1 7 8" L V L F L U S H B E A M (3 ) 1 3 4"x 1 1 7 8" L V L F L U S H B E A M (3 ) 1 3 4"x 1 1 7 8" L V L F L U S H B E A M MAIN FLOOR FRAMING PLAN 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 2 0 DA B 6/14/21 Reviewed by SAFEbuilt 08/30/2021 ROOF FRAMING NOTES: 1. TRUSS DESIGNS BY TRUSS MANUFACTURER INCLUDING UPLIFT AND CONNECTIONS. 2. SOLID BLOCKING FOR ALL REPETITIVE ROOF FRAMING MEMBERS TO BE PROVIDED AT ALL BEARING POINTS. 3. BEARING SURFACES FOR ALL BEAMS TO BE STUD PACKS WITH A MINIMUM WIDTH OF THE MEMBER BEING SUPPORTED UNLESS NOTED OTHERWISE. 4. GENERAL NAILING AND FRAMING REQUIREMENTS FOR ROOF FRAMING TO BE PER GENERAL NOTES ON SHEET S1. 5. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AND SLOPES FOR ROOF FRAMING. 6. SHEATHING REQUIREMENTS FOR THICKNESS AND NAILING PATTERNS TO BE PER GENERAL NOTES ON SHEET S1. 7. ALL WOOD STRUCTURAL MEMBERS TO BE HEM-FIR #2 OR BETTER UNLESS OTHERWISE NOTED. 8. EXTERIOR LUMBER TO BE EXTERIOR GRADE (PRESSURE TREATED) OR PROTECTED FROM ELEMENTS PER 2015 IRC REQUIREMENTS. 9. ALL OUT-LOOKERS TO BE FRAMED WITH 2x6 MEMBERS AND CONNECTED WITH SIMPSON H2.5 CLIPS @ EXTERIOR BEARING POINTS. 10. HEADERS TO MEET THE INSTALLATION REQUIREMENTS AS NOTED ON SHEET S1. ALL NON-STRUCTURAL HEADERS TO BE MIN (2) 2x10. 11. UPLIFT CONNECTIONS FOR ALL RAFTERS TO BE MADE WITH SIMPSON H2.5A CLIP @ EACH RAFTER TO PLATE/BEAM CONNECTION. HANGER SCHEDULE 117 8" RFPI40 RAFTERS - SIMPSON LSSR2.37Z HANGERS (2) 13 4"x71 4" LVL RAFTERS - SIMPSON HUS48 HANGERS P.E. ATTIC TRUSSES @ 24" O.C. 10 x 1 6 D F # 1 B E A M 8x8 POST W/SIMPSON CBT4Z BEAM TIE P. E . T R U S S E S @ 2 4 " O . C . P. E . T R U S S E S @ 2 4 " O . C . P. E . T R U S S E S @ 2 4 " O . C . P. E . T R U S S E S @ 2 4 " O . C . (2 ) 1 3 4"x 7 1 4" L V L @ 2 4 " O . C . (2 ) 1 3 4"x 7 1 4" L V L @ 2 4 " O . C . 2x 8 @ 2 4 " O . C . 2x 8 @ 2 4 " O . C . 117 8" RFPI40 @ 24" O.C.117 8" RFPI40 @ 24" O.C. P. E . T R U S S E S @ 2 4 " O . C . (2) 13 4"x117 8" LVL FLUSH BEAM(2) 13 4"x117 8" LVL FLUSH BEAM 10x10 POST WITH SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 DF#1 BEAM8x8 DF#1 BEAM (2 ) 1 3 4"x 9 1 2" L V L H E A D E R (2) 13 4"x91 2" LVL HEADER (2) 13 4"x91 2" LVL HEADER(3) 2x10 HEADER (3 ) 2 x 1 0 H E A D E R (2) 13 4"x91 2" LVL HEADER (3) 13 4"x91 2" LVL HEADER OVERFRAME AREA: 2x10 RAFTERS 24" O.C. (2) 2x10 RIDGE BEAM OVERFRAME AREA: 2x10 RAFTERS 24" O.C. (2) 2x10 RIDGE BEAM 2x 6 @ 1 6 " O . C . 8x12 DF#1 BEAM 8x8 POST W/SIMPSON CBT4Z BEAM TIE 8x8 POST W/SIMPSON CBT4Z BEAM TIE 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 2 0 DA B ROOF FRAMING PLAN 0'4'8'2' SCALE: 1/4" = 1'16' 6/14/21 Reviewed by SAFEbuilt 08/30/2021 WALL TYPE TYPE 1 (SHEAR WALL)- 2x6 @ 16" O.C. SHEATHING: EXTERIOR- 1 2" STRUCTURAL PANEL, BLOCKED NAIL W/8D COMMON NAILS 4" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/TYPE W COARSE DRYWALL SCREWS, 6" O.C. EDGE, 12" O.C. FIELD TYPE 2 (SHEAR WALL)- INTERIOR SHEAR WALL- 2X6 @ 16" O.C. SHEATHING: EXTERIOR- 1 2" STRUCTURAL PANEL, BLOCKED NAIL W/8D COMMON NAILS 6" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/TYPE W COARSE DRYWALL SCREWS, 6" O.C. EDGE, 12" O.C. FIELD TYPE 3 (SHEAR WALL)- REINFORCED CONCRETE WALL PER FOUNDATION PLAN NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR ALL NON-STRUCTURAL WALL ASSEMBLY REQUIREMENTS. 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 2 0 DA B LOWER FLOOR BRACED WALL PLAN 0'4'8'2' SCALE: 1/4" = 1'16' 6/14/21 Reviewed by SAFEbuilt 08/30/2021 WALL TYPE TYPE 1 (SHEAR WALL)- 2x6 @ 16" O.C. SHEATHING: EXTERIOR- 1 2" STRUCTURAL PANEL, BLOCKED NAIL W/8D COMMON NAILS 4" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/TYPE W COARSE DRYWALL SCREWS, 6" O.C. EDGE, 12" O.C. FIELD TYPE 2 (SHEAR WALL)- EXTERIOR SHEAR WALL- 2X6 @ 16" O.C. SHEATHING: EXTERIOR- 1 2" STRUCTURAL PANEL, BLOCKED NAIL W/8D COMMON NAILS 6" O.C. EDGE, 12" O.C. FIELD INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/TYPE W COARSE DRYWALL SCREWS, 6" O.C. EDGE, 12" O.C. FIELD TYPE 3 (SHEAR WALL)- INTERIOR SHEAR WALL- 2X6 @ 16" O.C. SHEATHING: INTERIOR- 1 2" GYPSUM BOARD, UNBLOCKED NAIL W/TYPE W COARSE DRYWALL SCREWS, 6" O.C. EDGE, 12" O.C. FIELD SIMPSON MSTC78 STRAP TIE - (64) 16d SINKERS NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR ALL NON-STRUCTURAL WALL ASSEMBLY REQUIREMENTS. S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 2 0 DA B MAIN FLOOR BRACED WALL PLAN 0'4'8'2' SCALE: 1/4" = 1'16' 6/14/21 Reviewed by SAFEbuilt 08/30/2021 FIRE MITIGATION PLAN 1860 SLEEPY HOLLOW CT. ESTES PARK, CO (LOT 6) Parcel number: 35224-38-006 A Portion of the SW¼, SE¼, Section 22 Township 5 North, Range 73 West 6th Principle Meridian Larimer County, CO Prepared by: Mike Hughes, Forester Fort Collins Field Office 970-491-8453 For: Robert Yone, owner August 12, 2021 Reviewed by SAFEbuilt 08/30/2021 Wildfire Mitigation Plan Plan August 2021 Page | 2 Purpose: The purpose of this plan is to evaluate the potential risks from a wildfire and minimize the impacts. It is followed by recommended actions to reduce those risks. There is no guarantee that structures will survive, but at the very least, firefighters will more likely defend a home that has mitigated the dangers versus one that has not. Potential: Wildfire risk evaluates the amount of fuels in an area, which can lead to more intense wildfire behavior and higher damage to the area. Mitigating the risk will decrease the extreme fire behavior and diminish negative effects in the case of a wildfire ignition. Wildfire risk is increased by dense tree arrangements, where crowns are touching or close together. Risk can also be increased due to the presence of “ladder fuels,” which allow a fire to burn from the ground up into the branches, and then into the crowns of larger trees. This can increase tree mortality and rate of fire spread. The accumulation of downed woody debris, litter, and duff also increases fire hazard. These surface fuels should also be mitigated, especially near any future structures. Current Conditions and Recommendations: The parcel at 1860 Sleepy Hollow is about two acres in size. It is estimated that there are less than 350 trees per acre, with an average slope of 25%. That combination put it at a moderate fire danger category. The aspect is mostly north facing. Forests, such as these, are usually unnaturally dense due to past fire suppression. However, there is evidence of past thinning, especially understory trees. Also, much of the forest has minimal ladder fuels. Lower limbs are sparsely evident. (photos below) There is not a lot of down and dead material on the site. Woody debris should be cleaned, however, in the few areas that have fuel on the ground. (photo on next page) Reviewed by SAFEbuilt 08/30/2021 Wildfire Mitigation Plan Plan August 2021 Page | 3 The major tree species is Ponderosa Pine with some scattered Douglas-fir and Rocky Mountain Juniper. Firs do not readily self-prune the main stem as does Ponderosa pine when they mature. It appears that many firs have been manually pruned. Juniper can be volatile during a wildfire, but a few should be retained for diversity. A few small pockets of dense trees on the parcel should be thinned to reduce the fuel load. There are small rock outcroppings on the west and east sides of the proposed building site. These act as natural firebreaks and can be enhanced by thinning on the perimeter. Some trees will be removed when construction begins. It is recommended, however, that defensible space guidelines be followed as outlined in the Home Ignition Zone CSFS Guide, once building is complete. Reviewed by SAFEbuilt 08/30/2021 Wildfire Mitigation Plan Plan August 2021 Page | 4 Beyond the defensible space zone, keep trees thinned to reduce fire danger across the parcel. Cut and remove dead, dying and less vigorous trees creating separation between crowns of healthy ‘leave trees’. Continuous canopy cover can become ‘fire chimneys’ during wildfires. The driveway below the house should act as a nice firebreak for a potential groundfire moving uphill. There are ravines on the west and east sides of the property, mostly off-site. These should be noted, however, as they can act as ‘fire chimneys’. Many fire hazards can be reduced by following these guidelines:  Thin tree and brush cover to 3’ of separation for shrubs and 10’ between tree branches.  Prune any remaining tree ladder fuels to a minimum of 6’ above ground.  Dispose of slash (branches) and debris left from thinning.  Minimize dead wood, needles and litter.  Continue to trim grasses and weeds. Keep watered, especially during high fire danger.  Keep roofs, gutters and eaves clean. Use synthetic decking whenever possible.  Trim branches which extend over roof and remove within 15’ of chimney. Yone Parcel, photo from Robert Reviewed by SAFEbuilt 08/30/2021 Wildfire Mitigation Plan Plan August 2021 Page | 5 The Colorado State Forest Service (CSFS) participates with other fire prevention cooperators in a program called FireWise, which will facilitate widespread implementation of pre-fire activities throughout Colorado. For more information concerning this program or if you would like to contact a forester, please contact the Fort Collins Field Office at: csfs_fortcollins@Mail.Colostate.edu or (970) 491-8660. Reviewed by SAFEbuilt 08/30/2021 GAS LINE PRESSURE___________________ ONE LINE DRAWING TO BE ON THIS FORM. ONE LINE TO SHOW ALL DISTANCES FROM POINT TO POINT, BTU'S, SIZES OF PIPE AND PIPE MATERIAL USED BACK TO THE METER. ALL EXISTING EQUIPMENT TO BE SHOWN, ALL NEW EQUIPMENT AND PIPING TO BE CLOUDED. CALULATIONS TO INCLUDE FITTINGS.