PLANS Residential Addition 1119 Morgan St 2021-07-27
DESIGN LOADS CODE: 2015 IRC W/ToEP LOCAL AMENDMENTS ELEV - 7650 FEET GROUND SNOW LOAD: 60 PSF @ 7000 FT, 70 PSF @ 8000 FT INTERPOLATED GROUND SNOW LOAD: 67 PSF ROOFS: ROOF DEAD LOAD: 15 PSF SLOPED ROOF SNOW LOAD Pg: 52 PSF FLOORS: FLOOR LIVE LOAD: 40 PSF FLOOR DEAD LOAD: 10 PSF DECK LIVE LOAD: 67 PSF DECK DEAD LOAD: 10 PSF WIND: ULTIMATE WIND SPEED: 175 MPH, EXP. C SEISMIC: DESIGN CATEGORY B ASSUMED SOIL BEARING CAPACITY: 2500 PSF (ENGINEER TO VERIFY) GENERAL NOTES 1. REFERENCES TO "ENGINEER" ON THE DRAWINGS REFERS TO THE STRUCTURAL ENGINEER OF RECORD. 2. LOCATE ALL UNDERGROUND UTILITIES AND NOTIFY ENGINEER OF EXISTING UTILITIES THAT CONFLICT OR INTERFERE WITH WORK. 3. DO NOT SCALE DRAWINGS. CONTACT DESIGNER FOR CLARIFICATION OF DIMENSIONING AND ANNOTATE ON THE RECORD DRAWINGS ANY MISSING DIMENSIONS. 4. DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. 5. DETAILS NOTED AS TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE. 6. THE STRUCTURE IS DESIGNED TO FUNCTION AS A COMPLETE UNIT. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S METHODS AND SEQUENCING OF CONSTRUCTION. 7. USE ONLY HAND OPERATED TOOLS FOR COMPACTION ADJACENT TO FOUNDATION WALLS AND STEM WALLS. EXCAVATION 1. EXCAVATE SOIL TO ACCOMMODATE NEW FOOTINGS TO DEPTHS AS SHOWN ON THE DRAWINGS. HAND TRIM ALL EXCAVATIONS AS REQUIRED AND REMOVE LOOSE/SOFT MATERIALS. 2. FOOTINGS HAVE BEEN DESIGNED FOR AN ASSUMED ALLOWABLE SOIL BEARING PRESSURE OF 2,500 PSF. 3. PROTECT THE SITE AND ALL CONSTRUCTION, EXISTING AND PROPOSED, FROM THE EFFECTS OF FREEZING OR FROST ACTION. 4. PLACE AND COMPACT BACKFILL IN EQUAL CONTINUOUS LAYERS NOT EXCEEDING 9" OF COMPACTED DEPTH FOR HAND HELD COMPACTION EQUIPMENT AND A MAXIMUM OF 12" INCHES COMPACTED DEPTH FOR VIBRATORY ROLLERS. 5. MAINTAIN OPTIMUM MOISTURE CONTENT OF BACKFILL MATERIALS TO ATTAIN COMPACTION DENSITY. 6. BACKFILL SIMULTANEOUSLY ON EACH SIDE OF FOUNDATION WALLS THAT ARE NOT DESIGNED FOR RETAINING SOIL ON ONE SIDE. 7. IMPORTED GRANULAR BACKFILL TO MEET THE FOLLOWING CRITERIA: SIEVE DESIGNATION % BY WEIGHT PASSING SIEVES 3 INCH 100 NO. 4 45-75 NO. 100 0-12 NO. 200 0-6 8. SUITABLE NATIVE SOIL: ON SITE SAND OR GRAVEL REASONABLY FREE OF LOAM, SILT, CLAY, OR ORGANIC MATTER. CAST-IN-PLACE CONCRETE 1. ALL WORK SHALL COMPLY WITH ACI 301-10, UNLESS NOTED OTHERWISE IN DRAWINGS OR SPECIFICATIONS. 2. DETAIL BARS IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS AND ACI PUBLICATION SP-66 (2004): "ACI DETAILING MANUAL". 3. REINFORCING MATERIALS: TYP REINFORCING - ASTM A615, Fy=60 KSI, Fu=90 KSI WELDED AND FIELD BENT REINF - ASTM A706, Fy=60 SKI, Fu=90 KSI WELDED WIRE REINFORCING, SMOOTH - ASTM A1064, Fy=65 KSI, Fu=75 KSI WELDED WIRE REINFORCING, DEFORMED - ASTM A1064, Fy=70 KSI, Fu=80 KSI EPOXY COATED REINFORCING - ASTM A775 OR ASTM A934 3. REINFORCING FABRICATION: a. NO SPLICING OF REINFORCEMENT PERMITTED EXCEPT AS NOTED ON THE DRAWINGS. MAKE BARS CONTINUOUS AROUND CORNERS WHERE DETAILS ARE NOT PROVIDED. WHERE PERMITTED, MAKE SPLICES WITH CONTACT LAPS OR MECHANICAL CONNECTORS. b. PROVIDE ADDITIONAL BARS/STIRRUPS REQUIRED TO SECURE REINFORCING IN PLACE DURING CONCRETE PLACEMENT. c. MAKE ALL REINFORCING BAR BENDS IN THE FABRICATOR'S SHOP. d. NO WELDING OF REINFORCING IS PERMITTED UNLESS NOTED ON THE DRAWINGS. 4. CONCRETE MIX REQUIREMENTS: a. MIX TYPE 1- FOOTINGS, PILASTERS, STEM WALLS, BASEMENT WALLS NOT EXPOSED TO FREEZING OR MOISTURE -28 DAY COMPRESSIVE STRENGTH, f'c=3000 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM AGGREGATE SIZE = 1" b. MIX TYPE 2- FOOTINGS, PILASTERS, STEM WALLS, BASEMENT WALLS EXPOSED TO FREEZING OR MOISTURE -28 DAY COMPRESSIVE STRENGTH. f'c=4500 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM W/C RATIO 0.45 -MAXIMUM AGGREGATE SIZE = 3 4" -TOTAL AIR CONTENT 5% c. MIX TYPE 3- ALL CONCRETE EXPOSED TO WEATHER OR DEICER, BEAMS, SLABS AND WALLS -28 DAY COMPRESSIVE STRENGTH, f'c=5000 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM W/C RATIO 0.4 -MAXIMUM AGGREGATE SIZE = 3 4" -TOTAL AIR CONTENT 6% d. MIX TYPE 4- INTERIOR TOPPING SLABS AND SLABS ON DECK -28 DAY COMPRESSIVE STRENGTH, f'c=3500 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM W/C RATIO 0.5 -MAXIMUM AGGREGATE SIZE = 3 4" -ADDITION OF ENTRAINED AIR NOT PERMITTED e. MIX TYPE 5- INTERIOR SLAB ON GRADE -28 DAY COMPRESSIVE STRENGTH, f'c=3500 PSI -NORMAL WEIGHT CONCRETE -MAXIMUM AGGREGATE SIZE = 1" -ADDITION OF ENTRAINED AIR NOT PERMITTED 3. PROPORTIONS OF MATERIALS IN CONCRETE MIX SHALL BE ESTABLISHED TO PROVIDE THE MINIMUM COMPRESSIVE STRENGTH REQUIRED AND PROVIDE WORKABILITY AND CONSISTENCY TO PERMIT CONCRETE TO BE WORKED READILY INTO FORMS AND AROUND REINFORCEMENT WITHOUT SEGREGATION OR EXCESSIVE BLEEDING. USE ADMIXTURES AS REQUIRED TO OBTAIN DESIRED RESULTS. DO NOT EXCEED THE MAXIMUM WATER-CEMENT RATIO. 4. USE PORTLAND TYPE I/II CEMENT UNLESS OTHERWISE NOTED. FOR CONCRETE MIXES USED ON FLOORS MINIMUM CEMENTITIOUS CONTENT SHALL BE 540 POUNDS PER CUBIC YARD. 5. AGGREGATE TO BE PER ASTM C33. 3 4" AGGREGATE TO MEET SIZE #67 AGGREGATE, 1" AGGREGATE TO MEET SIZE #57 AGGREGATE. 6. PLACE NO CONCRETE WHEN AMBIENT TEMPERATURE IS BELOW 40 DEGREES FAHRENHEIT OR MORE THAN 90 DEGREES FAHRENHEIT UNLESS PLACEMENT PROCEDURE IS IN COMPLIANCE WITH ACI 305 OR ACI 306. 7. COMPLY WITH ACI CODES AND PLACE CONCRETE IN A CONTINUOUS OPERATION WITHIN PLANNED JOINTS OR SECTIONS. DO NOT PERMIT COLD JOINTS TO OCCUR. 8. GROUT: PRE-MIXED, NON-SHRINK, WITH MINIMUM COMPRESSIVE STRENGTH OF 6000 PSI AT 28 DAYS. 9. NO CONCRETE SHALL BE DROPPED MORE THAN 4 FEET INSIDE A FORM. 10. CONCRETE FORMS SHALL BE CLEAN AND FREE FROM DEBRIS. IF FORMS ARE COATED WITH A RELEASE AGENT, THE RELEASE AGENT SHALL BE COLORLESS MINERAL OIL WHICH SHALL NOT STAIN CONCRETE OR ABSORB MOISTURE OR IMPAIR NATURAL BONDING OF CONCRETE. 11. CONTRACTOR IS RESPONSIBLE FOR ALL FORM DESIGN/BRACING REQUIREMENTS. 12. UNLESS OTHERWISE NOTED, CENTER ALL FOUNDATION PIERS AND FOOTINGS ON COLUMN CENTERLINES. 13. CHAIRS AND SPACERS SHALL BE PLACED TO ADEQUATELY SUPPORT REINFORCING DURING PLACEMENT. FOREIGN MATERIALS SUCH AS WOOD OR OTHER UNSUITABLE SUPPORTS SHALL NOT BE USED TO SUPPORT REINFORCING. SET WIRE TIES SO ENDS ARE DIRECTED INTO CONCRETE WHERE CONCRETE WILL BE EXPOSED. 14. CONCRETE CLEAR COVER FOR REINFORCEMENT (UNLESS SHOWN OTHERWISE): a. BOTTOM OF FOOTINGS AND SLABS ON GRADE: 3". b. FOUNDATION WALLS AND EXTERIOR WALLS: 2". c. TOP AND BOTTOM OF ELEVATED SLABS: 3/4". d. ALL FACES OF PIERS: 1-1/2". 15. FOOTINGS a. SIZE AND DEPTH AS INDICATED ON THE DRAWINGS. b. MINIMUM FROST PROTECTION DEPTH TO BE 30". 16. WALLS a. WALL THICKNESS TO BE 8" OR AS NOTED ON THE DRAWINGS. b. VERTICAL STEEL TO HOOK INTO FOOTING AS NOTED ON THE DRAWINGS. c. VERTICAL STEEL TO EXTEND ABOVE FOOTING MINIMUM OF 24", UNLESS NOTED OTHERWISE, FOR SPLICE ABOVE. d. 1 2" ANCHOR BOLTS FOR SILL PLATES SHALL BE IMBEDDED 7" MINIMUM AND SHALL BE PLACED A MINIMUM OF 48" O.C. AND WITHIN 12" OF EACH END OF ALL SILL PLATES. d. ANCHOR BOLTS TO HAVE MINIMUM 3 16"x2"x2" WASHER. WOOD FRAMING AND SHEATHING 1. IN-GRADE BASE VALUES HAVE BEEN USED FOR THIS DESIGN. 2. 2x FRAMING SHALL BE HEM-FIR #2 AND BETTER UNLESS OTHERWISE NOTED. 3. ALL LUMBER SHALL BE 19% MAXIMUM MOISTURE CONTENT. 4. SOLID TIMBER BEAMS AND POSTS SHALL BE DOUGLAS FIR-LARCH #1 OR BETTER UNLESS OTHERWISE NOTED. 5. WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 6. PRESERVATIVE TREATED WOOD SHALL BE TREATED IN ACCORDANCE WITH AWPA U1 AND AEPA M4. 7. LVL FRAMING SHALL BE LAMINATED DOUGLAS FIR OR SOUTHERN PINE (GP LAM BY GEORGIA PACIFIC OR MICROLAM BY TRUS-JOIST OR EQUIVALENT) MEETING THE FOLLOWING MINIMUM ALLOWABLE STRESS CRITERIA: FB (BENDING STRESS) = 2600 PSI FV (HORIZ. SHEAR STRESS) = 285 PSI E (MODULUS OF ELASTICITY) = 1,900,000 PSI FC (COMPRESSION PERPENDICULAR TO GRAIN) = 750 PSI 8. I-JOISTS SHALL BE AS NOTED ON THE STRUCTURAL DRAWINGS AND MEET THE PROVISIONS OF ASTM D5055. 9. PROVIDE SOLID BLOCKING BETWEEN JOISTS UNDER JAMB STUDS OF OPENINGS. 10. COLUMNS MUST HAVE A CONTINUOUS LOAD PATH TO THE FOUNDATION. 11. UNLESS OTHERWISE INDICATED, INSTALL TWO LENGTHS OF SOLID BLOCKING x JOIST DEPTH x 12 INCHES LONG IN THE FLOOR FRAMING UNDER COLUMN LOADS. 12. ALL BEAMS AND TRUSSES SHALL BE BRACED AGAINST ROTATION AT POINTS OF BEARING. 13. UNLESS NOTED ON THE DRAWINGS, LOWER CHORD OF GABLE END TRUSSES SHALL BE ANCHORED TO WALL PLATE WITH FRAMING ANCHORS AT 4' SPACING AND LATERALLY BRACED TO ROOF FRAMING AT 8' SPACING. 14. MINIMUM NAILING SHALL BE AS SPECIFIED IN IBC TABLE 2304.9.1 "FASTENING SCHEDULE". 15. METAL FRAMING ANCHORS SHOWN OR REQUIRED SHALL BE SIMPSON STRONG TIE OR EQUAL CODE APPROVED CONNECTORS AND INSTALLED WITH THE NUMBER AND TYPE OF NAILS RECOMMENDED BY THE MANUFACTURER TO ACHEIVE THE RATED CAPACITY. HEAVY-DUTY AND SKEWED HANGERS MAY REQUIRE SPECIAL ORDER AND NOT STOCKED LOCALLY. 16. ALL RAFTERS, JOISTS, TRUSSES AND BEAMS SHALL BE ANCHORED TO SUPPORTS WITH METAL FRAMING ANCHORS. 17. LEAD HOLES FOR LAG SCREWS SHALL BE 40%-70% OF THE SHANK DIAMETER OF THE THREADED SECTION AND EQUAL TO THE SHANK DIAMETER AT THE UNTHREADED SECTION. 18. CONNECTOR BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME B18.2.1 AND ASTM SAE J429 GRADE 1. NAILS AND SPIKES SHALL CONFORM TO ASTM F1667. 19. WOOD SCREWS SHALL CONFORM TO ANSI/ASME B18.6.1. 20. ROOF, FLOOR AND WALL SHEATHING: APA RATED OR ADVANTECH VIP+ SHEATHING, THICKNESS AS INDICATED, SPAN RATING AS REQUIRED TO SUIT SUPPORT SPACING INDICATED, EXPOSURE DURABILITY 1, THREE SPAN MINIMUM. 21. SUB-FLOOR GLUE: APA AFG-01, WATERPROOF OF WATER SOLVENT BASE, AIR CURE TYPE, CARTRIDGE DISPENSED. 22. MINIMUM FLOOR SHEATHING - 23/32" APA STURD-I-FLOOR RATED 24" O.C. TONGUE AND GROOVE, GLUED AND NAILED. 23. MINIMUM ROOF SHEATHING - 5/8" OSB OR CDX PLYWOOD, APA 40/20, NAILED. 24. MINIMUM EXTERIOR WALL SHEATHING - 7/16" OSB OR CDX PLYWOOD, APA 24/16, BLOCKED AS NOTED AND NAILED. 25. MINIMUM INTERIOR WALL SHEATHING - 1/2" GYPSUM BOARD, ASTM C 1396/C 1396M 26. WALL SHEATHING TO BE NAILED WITH 8d COMMON NAILS OR 10d BOX NAILS AT 6" O.C. AT PANEL EDGES AND 12" O.C. AT INTERMEDIATE FRAMING EXCEPT AS NOTED. NAIL ALL PLATES USING THE EDGE NAILING NOTED. 27. SHEATHE ALL EXTERIOR WALLS. SHEATHE INTERIOR WALLS AS NOTED ON ARCHITECTURAL DRAWINGS. 28. SHEATHING SHALL BE CONTINUOUS FROM TOP PLATE TO BOTTOM PLATE. CUT IN "L" AND "T" SHAPES AROUND OPENINGS. 29. LAP SHEATHING OVER RIM JOISTS A MINIMUM OF 4" AT ALL FLOORS TO TIE UPPER AND LOWER WALL STUDS TOGETHER. INSTALL METAL STRAPS AS INDICATED ON THE BRACED WALL DRAWINGS. 30. MINIMUM HEIGHT OF SHEATHING PANELS TO BE 16" TO ENSURE THAT PLATES ARE TIED TO STUDS. 31. MAKE PROVISIONS FOR ERECTION LOADS, AND FOR SUFFICIENT TEMPORARY BRACING TO MAINTAIN STRUCTURE SAFE, PLUMB, AND IN TRUE ALIGNMENT UNTIL COMPLETION OF ERECTION AND INSTALLATION OF PERMANENT BRACING. 32. SECURE ROOF SHEATHING WITH LONGER EDGE PERPENDICULAR TO FRAMING MEMBERS AND WITH ENDS STAGGERED AND SHEET ENDS OVER BEARING. 33. WHERE TONGUE AND GROOVE PLYWOOD IS USED, FULLY ENGAGE TONGUE AND GROOVE EDGES. 34. SECURE SUB-FLOOR SHEATHING WITH LONGER EDGE PERPENDICULAR TO FLOOR FRAMING AND WITH END JOINTS STAGGERED AND SHEET ENDS OVER BEARING. ATTACH WITH SUB-FLOOR GLUE AND DRYWALL SCREWS. 35. RIM BOARD SHALL BE 1 ¼" LSL ATTACHED TO I-JOISTS WITH 10D NAILS - ONE INTO EACH FLANGE. RIM BOARD SHALL BE TOE NAILED TO PLATE WITH 10D NAILS AT 6 INCHES ON CENTER. I JOISTS SHALL BE ATTACHED TO PLATE WITH 8D NAILS DRIVEN AT AN ANGLE INTO BOTTOM FLANGE - ONE ON EACH SIDE OF WEB AT LEAST 1 ½ INCHES FROM END. 36. FLOOR SHEATHING SHALL BE ATTACHED TO JOISTS WITH 8D NAILS AT 6 INCHES ON CENTER EDGES AND 12 INCHES ON CENTER FIELD. TOE PLATE OF WALL FRAMING TO BE ATTACHED TO RIM BOARD WITH 16D NAILS AT 4-INCHES ON CENTER. EXTERIOR STUDS TO BE 2X6 AND TO BE END NAILED TO SILL AND TOP PLATE WITH A MINIMUM OF (2) 16D NAILS. ALL DOUBLE TOP PLATE SPLICES IN EXTERIOR WALLS TO LAP 6 FEET WITH 18 10D NAILS EACH SIDE OF SPLICE. FLOOR SHEATHING TO BE 3 4" OSB TONGUE AND GROOVE. 37. FOR WINDOW AND DOOR HEADERS, THE NUMBERS OF FULL HEIGHT STUDS, JACK STUDS (TRIMMERS) AND HEADER UPLIFT ATTACHMENTS SHALL BE PER THE TABLE ON THIS SHEET. HEADER SIZES SHALL BE AS NOTED ON THE STRUCTURAL DRAWINGS. 38. SPECIAL NAILING REQUIREMENTS: a. ROOF SHEATHING -ALL NAILS TO BE 8d COMMON OR 10d BOX. -SHEATHING TO BE NAILED WITHIN 4 FEET OF THE PERIMETER AND RIDGE OF THE ROOF 3" O.C. EDGE AND FIELD. -ALL OTHER PANELS NAILED 6" O.C. EDGE, 12" O.C. FIELD. b. INTERIOR GYPSUM WALL BOARD -GYPSUM BOARD TO BE MIN 1/2" THICK. -MAXIMUM STUD SPACING 16" O.C. UNLESS NOTED OTHERWISE. -PANELS TO BE FASTENED 7" O.C. EDGE AND 10" O.C. FIELD. -FASTENERS TO BE 1 1/4" NO. 6 TYPE S OR W DRYWALL SCREWS, 5d COOLER NAILS. -FASTENERS TO BE SPACED NO LESS THAN 3/8" FROM EDGES AND ENDS OF GYPSUM BOARDS. -FOUR FOOT WIDE PIECES OF SHEATHING SHALL BE APPLIED PARALLEL OR PERPENDICULAR TO STUDS. -TWO FOOT WIDE PIECES SHALL BE APPLIED PERPENDICULAR TO STUDS. -STAGGER END JOINTS OF ADJACENT COURSES OF GYPSUM BOARD SUCH THAT THEY DONT OCCUR OVER SAME STUD. c. CONTINUOUS EXTERIOR WOOD STRUCTURAL PANEL -PANELS UP TO 1/2" SHALL BE NAILED W/8d COMMON NAILS 6" O.C. EDGE, 12" O.C. FIELD. -PANELS OVER 1/2" THICK SHALL BE NAILED W/8d NAILS 6" O.C. EDGE, 12" O.C. FIELD. -BLOCKING OF PANEL EDGES SHALL BE INSTALLED AS NOTED ON THE BRACED WALL DRAWINGS. 11 9 1 W O O D S T O C K D R I V E , S U I T E A , E S T E S P A R K , C O 8 0 5 1 7 ww w . t r a i l r i d g e c e . c o m * 9 7 0 - 3 0 8 - 8 2 2 1 * d b a n g s @ t r a i l r i d g e c e . c o m © 2 0 2 0 DA B TYPICAL DETAILS/CONSTRUCTION SCHEDULES 7/7/21 STRUCTURAL STEEL NOTES 1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" (AISC 360) AND THE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" (AISC 303) BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). 2. STRUCTURAL STEEL WIDE FLANGE BEAMS AND WTs SHALL CONFORM TO ASTM A992, 50 KSI YIELD. 3. ROLLED STEEL FLOOR PLATES SHALL CONFORM TO ASTM A786-05, COMMERCIAL GRADE. 4. OTHER ROLLED SHAPES, INCLUDING PLATES, CHANNELS, WTs AND ANGLES SHALL CONFORM TO ASTM A36, 36 KSI YIELD. 5. HOLLOW STRUCTURAL STEEL SECTIONS (HSS) RECTANGULAR SHAPES SHALL CONFORM TO ASTM A500, GRADE B, 46 KSI YIELD. 6. HSS ROUND SHAPES SHALL CONFORM TO ASTM A500, GRADE B, 42 KSI YEILD. 7. PIPE SHAPES SHALL CONFORM TO ASTM A53-12, GRADE B, 35 KSI YIELD. 8. EXCEPT AS NOTED, FRAMED BEAM CONNECTIONS SHALL BE BEARING-TYPE WITH 3/4" DIAMETER, SNUG TIGHT, ASTM A325-04 BOLTS, DETAILED IN CONFORMANCE WITH THE STRUCTURAL DRAWINGS AND THE "STEEL CONSTRUCTION MANUAL" BY THE AISC, 13TH EDITION. INSTALL BOLTS IN ACCORDANCE WITH AISC'S "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS," 2010. 9. ALL BEAMS SHALL HAVE FULL DEPTH WEB STIFFENERS EACH SIDE OF WEBS ABOVE AND BELOW COLUMNS. 10. ANCHOR RODS SHALL CONFORM TO ASTM F1554-99, GRADE (36, 55, AND/OR 105) AS NOTED ON THE STRUCTURAL DRAWINGS WITH WELDABILITY SUPPLEMENT S1. 11. WELDING SHALL BE DONE BY A CERTIFIED WELDER IN ACCORDANCE WITH THE AISC DOCUMENTS LISTED ABOVE, THE AMERICAN WELDING SOCIETY (AWS) D1.1: 2010 STRUCTURAL WELDING CODE, AND THE RECOMMENDATIONS FOR USE OF WELD E70 ELECTRODES. WHERE NOT SPECIFICALLY NOTED, MINIMUM WELD SHALL BE 3/16" FILLET BY LENGTH OF CONTACT EDGE. 12. ALL POST-INSTALLED ANCHORS SHALL HAVE CURRENT INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORTS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 15. EXPANSION ANCHORS SHALL BE APPROVED "WEDGE" TYPE UNLESS SPECIFICALLY NOTED TO BE "SLEEVE" TYPE AS NOTED ON THE STRUCTURAL DRAWINGS. 16. POST INSTALLED BOLTS AND REBAR SHALL USE AN APPROVED EPOXY OR SIMILAR ADHESIVE TYPE AS APPROPRIATE FOR INSTALLATION IN SOLID AND NON-SOLID BASE MATERIALS. 17. GROUT BENEATH COLUMN BASE AND BEAM BEARING PLATES SHALL HAVE A MINIMUM 28-DAY, COMPRESSIVE STRENGTH OF 7,500 PSI AND SHALL BE NON-SHRINK, NON-METALLIC, AND TESTED IN ACCORDANCE WITH ASTM C1107-13. 18. WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE AWS. QUALIFICATION TESTS. 19. MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN 3/16”h FILLET, CONTINUOUS UNLESS OTHERWISE NOTED. 20. WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED. INCREASE WELD SIZE IF GAPS EXIST AT THE FAYING SURFACE. 21. WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY ANSI/AISC 360-05 TABLES J2.3 AND J2.4. 22. ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED. OPEN-WEB WOOD TRUSS NOTES 1. MANUFACTURE AND INSTALLATION OF METAL PLATED WOOD TRUSSES SHALL COMPLY WITH ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL-PLATE-CONNECTED WOOD TRUSS CONSTRUCTION," BCSI-2008 (BUILDING COMPONENT SAFETY INFORMATION) "GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING & BRACING OF METAL PLATE CONNECTED WOOD TRUSSES," AND DSB-89 "RECOMMENDED DESIGN SPECIFICATION FOR TEMPORARY BRACING OF METAL PLATE CONNECTED WOOD TRUSSES." 2. PRE-ENGINEERED, PREFABRICATED TRUSSES SHALL BE DESIGNED BY AN ENGINEER REGISTERED IN THE STATE OF COLORADO, AND SHALL COMPLY WITH CODE REQUIREMENTS. 3. TRUSSES SHALL BE DESIGNED TO SUPPORT THE FULL DEAD LOADS AND THE SUPERIMPOSED DESIGN LOADS NOTED ABOVE OR ON THE DRAWINGS. 4. STRESSES SHALL NOT EXCEED THOSE LISTED IN THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH 2005 SUPPLEMENT (AF&PA NDS-2005). <NO INCREASES IN STRESS ARE ALLOWED FOR DURATION OF LOAD.> 5. THE FABRICATOR SHALL DETERMINE TRUSS WEB ARRANGEMENTS AND MEMBER FORCES. 6. TRUSS TO TRUSS CONNECTIONS SPECIFIED SHALL BE BY TRUSS SUPPLIER, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. 7. UNLESS OTHERWISE INDICATED, TRUSSES SHALL BE DESIGNED FOR PERPENDICULAR TO GRAIN BEARING ON HEM FIR PLATES (405 PSI). END GRAIN BEARING IS NOT ALLOWED UNLESS ACCEPTED IN WRITING BY ENGINEER. DESIGN TRUSS FOR BEARING BLOCKS OR TRUSS BEARING ENHANCERS AS REQUIRED TO COMPENSATE FOR OVERSTRESSES. SPECIFY SIZE, SPECIES, AND NAILING FOR BEARING BLOCKS. 8. TRUSS FABRICATOR SHALL SPECIFY ALL FLOOR AND ROOF TRUSS BRACING AND BRIDGING. CALCULATIONS AND SHOP DRAWINGS, INCLUDING MEMBER SIZES, LUMBER SPECIES AND GRADES, AND SUBSTANTIATING DATA FOR CONNECTOR CAPACITIES, SHALL BE SUBMITTED TO THE ENGINEER/LOCAL ENTITY BUILDING OFFICIAL FOR REVIEW PRIOR TO FRAMING INSPECTION. APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 07/27/2021 This structure must comply with the requirements of the 2017 National Electrical Code PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION Ice barrier required from the lowest edges of all roof surfaces to a point not less than 24" inside the exterior wall line of the building. IRC R905.1.2 All architectural plans, engineered foundation plans, soils reports, truss drawings, energy code report or ResCheck must be onsite for inspections. Reviewed by SAFEbuilt 07/27/2021 Sheet No. Gl a c i e r C r e e k C o n s t r u c t i o n 11 9 1 G r a v e s A v e . Es t e s P a r k , C o . 8 0 5 1 7 (9 7 0 ) - 5 8 6 - 1 6 8 5 Gi l l a m R e s i d e n c e Ap a r t m e n t A d d i t i o n 11 1 9 M o r g a n D r i v e Es t e s P a r k , C o . 8 0 5 1 7 Date: May 3, 2021 1 2" 11 2" 11 2" STIFFENER ⅊ 1 2" EA. SIDE OF WEB CAP ⅊ 1 2" W/(2)3 4" BOLTS k, TYP 11 2", MIN 11 2", MIN k, TYP 1 2", MIN HSS PER PLAN WF PER PLAN 3 16 AT HSS TYP 5 16 5 16 21 2"5"21 2" 21 2" 5" 21 2" 10"x10"x3 4" PL 3 4"∅ F1550 THREADED ROD IN STANDARD HOLE HSS COLUMN 2x2x1 4 WASHER 1 4 ANCHOR BOLT & BASE PLATE HSS COLUMN PER PLAN 11 2" GROUT PAD (4) #4 BARS W/6" HOOK VERT REINFORCING #3 HORIZ TIES 16" O.C. 10" EMBED LENGTH 4" PROJECTION LENGTH CONC. PIER PER PLAN DOUBLE NUT OR HEADED ANCHOR ROD 30" MIN CONC. FOOTING PER PLAN Typical Footing Detail Not to scale Top of column to beam Details Not to scale Bottom plate to footing Plan Not to scale 7/7/21 PROVIDE ENGINEERED TRUSS LAYOUT AND PRODUCT SPECS ON SITE FOR THE INSPECTOR Reviewed by SAFEbuilt 07/27/2021 Sheet No. De s i g n e r ' s I n k 59 8 W . 4 8 t h S t r e e t , L o v e l a n d , C O . Ph o n e : ( 9 7 0 ) 2 1 3 - 7 4 3 1 De s i g n a n d D r a f t i n g s e r v i c e s Gl a c i e r C r e e k C o n s t r u c t i o n 11 9 1 G r a v e s A v e . Es t e s P a r k , C o . 8 0 5 1 7 (9 7 0 ) - 5 8 6 - 1 6 8 5 Gi l l a m R e s i d e n c e Ap a r t m e n t A d d i t i o n 11 1 9 M o r g a n D r i v e Es t e s P a r k , C o . 8 0 5 1 7 Date: May 3, 2021 Notes to N1102.1.2 The first R-value applies to continuous insulation, the second to framing cavity insulation; either insulation method meets the requirement. R-38 shall be deemed to satisfy the requirements of R-49 wherever full height R-38 insulation extends over the wall top plate at the eaves. Energy Efficiency Notes: • All heating and cooling equipment shall be sized such that the total sensible capacity of the cooling equipment does not exceed the total sensible load by more than 25% for cooling-only applications, or by more than 40% for heating applications • At least 75 percent of lamps in permanently installed lighting fixtures shall be high-efficacy lamps. • A signed air leakage testing report by an approved third party showing a maximum rate of three air changes per hour at 50 Pascals pressure must be provided to the building official. Testing must be conducted in accordance with RESNET/ICC 380, ASTM E779 or ASTM E1827. • All ductwork outside the building thermal envelope requires a passing duct leakage test report be turned in to the building official by final inspection per IRC Section N1103.3.3. Insulation and Fenestration Requirements by Component IRC Table N1102.1.2 MAY NOT COMPRESS INSULATION Reviewed by SAFEbuilt 07/27/2021 Sheet No. De s i g n e r ' s I n k 59 8 W . 4 8 t h S t r e e t , L o v e l a n d , C O . Ph o n e : ( 9 7 0 ) 2 1 3 - 7 4 3 1 De s i g n a n d D r a f t i n g s e r v i c e s Gl a c i e r C r e e k C o n s t r u c t i o n 11 9 1 G r a v e s A v e . Es t e s P a r k , C o . 8 0 5 1 7 (9 7 0 ) - 5 8 6 - 1 6 8 5 Gi l l a m R e s i d e n c e Ap a r t m e n t A d d i t i o n 11 1 9 M o r g a n D r i v e Es t e s P a r k , C o . 8 0 5 1 7 Date: May 3, 2021 7/7/21 TEMPERED AT LANDING 2015 IECC sec. R402.4.4 Appliances must be direct vent (combustion and exhaust) or the mechanical equipment must be located within a room entirely isolated from the rest of the building's thermal envelope in accordance with sec. R402.4.4 Reviewed by SAFEbuilt 07/27/2021 Sheet No. De s i g n e r ' s I n k 59 8 W . 4 8 t h S t r e e t , L o v e l a n d , C O . Ph o n e : ( 9 7 0 ) 2 1 3 - 7 4 3 1 De s i g n a n d D r a f t i n g s e r v i c e s Gl a c i e r C r e e k C o n s t r u c t i o n 11 9 1 G r a v e s A v e . Es t e s P a r k , C o . 8 0 5 1 7 (9 7 0 ) - 5 8 6 - 1 6 8 5 Gi l l a m R e s i d e n c e Ap a r t m e n t A d d i t i o n 11 1 9 M o r g a n D r i v e Es t e s P a r k , C o . 8 0 5 1 7 Date: May 3, 2021 PROVIDE FALL PROTECTION OPENINGS MAY NOT BE GREATER THAN 4" IN DIAMETER Reviewed by SAFEbuilt 07/27/2021 Sheet No. De s i g n e r ' s I n k 59 8 W . 4 8 t h S t r e e t , L o v e l a n d , C O . Ph o n e : ( 9 7 0 ) 2 1 3 - 7 4 3 1 De s i g n a n d D r a f t i n g s e r v i c e s Gl a c i e r C r e e k C o n s t r u c t i o n 11 9 1 G r a v e s A v e . Es t e s P a r k , C o . 8 0 5 1 7 (9 7 0 ) - 5 8 6 - 1 6 8 5 Gi l l a m R e s i d e n c e Ap a r t m e n t A d d i t i o n 11 1 9 M o r g a n D r i v e Es t e s P a r k , C o . 8 0 5 1 7 Date: May 3, 2021 7/7/21 Reviewed by SAFEbuilt 07/27/2021 Gillam Addition HVAC Load Calculations for Glacier Creek Const. Prepared By: Rexs Allen Air-City Heating And A/C LLC Friday, July 9, 2021 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 2 Project Report General Project Information Project Title:Gillam Addition Designed By:Glacier Creeki Cont. Project Date:Friday, July 9, 2021 Client Name:Glacier Creek Const. Company Name:Air-City Heating And A/C LLC Company Representative:Rexs Allen Design Data Reference City:Estes Park, Colorado Building Orientation:Front door faces North Daily Temperature Range:High Latitude:40 Degrees Elevation:4935 ft. Altitude Factor:0.834 Elevation Heating Adj. Factor:0.760 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:4 0.21 n/a 30%72 40.39 Summer:89 62 23%50%75 -21 Check Figures Total Building Supply CFM:228 CFM Per Square ft.:0.327 Square ft. of Room Area:699 Square ft. Per Ton:1,986 Volume (ft³):5,592 Building Loads Total Heating Required Including Ventilation Air:20,094 Btuh 20.094 MBH (Based On 0.760 Derating) Total Sensible Gain:4,504 Btuh 100 % Total Latent Gain:-280 Btuh 0 % Total Cooling Required Including Ventilation Air:4,504 Btuh 0.38 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 3 Miscellaneous Report System 1 Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:4 0.21 18%30%72 40.39 Summer:89 62 23%50%75 -21.20 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:Yes Yes Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:0 ft./min 0 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:5 in.5 in. Maximum Height:8 in.8 in. Outside Air Data Winter Summer Infiltration Specified:0.210 AC/hr 0.110 AC/hr 20 CFM 10 CFM Infiltration Actual:0.168 AC/hr 0.000 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 5,592 X 5,592 937 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:16 CFM 0 CFM Total Building Ventilation:12 CFM 12 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 12.85 = (1.10 X 0.834 X 14.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: -12.02 = (0.68 X 0.834 X -21.20 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 62.39 = (1.10 X 0.834 X 68.00 Winter Temp. Difference) Winter Infiltration Specified:0.210 AC/hr (20 CFM), Construction: Tight Summer Infiltration Specified:0.110 AC/hr (10 CFM), Construction: Tight Duct Load Factor Scenarios for System 1 No.Type Description Location Attic Ceiling Duct Leakage Duct Insulation Surface Area From [T]MDD 1 Supply Open Crawl -0.12 8 184 No 1 Return Open Crawl -0.12 8 68 No C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 4 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 0.38 1,986 699 4,504 -280 4,504 15,271 214 228 228 System 1 0.38 1,986 699 4,504 -280 4,504 15,271 214 228 228 7x8 Ventilation 152 -142 152 736 Supply Duct Latent -60 0 Return Duct 163 -78 85 796 Humidification 719 Zone 1 699 4,190 0 4,190 13,021 214 228 228 7x8 1-Closet 32 72 0 72 900 15 4 4 1--5 2-Bedr4oom 132 613 0 613 1,780 29 33 33 1--5 3-Desk 44 190 0 190 597 10 10 10 1--5 4-Bath/Laundry 99 253 0 253 1,810 30 14 14 1--5 5-Living Room 169 1,682 0 1,682 3,865 63 92 92 1--6 6-Kitchen 143 381 0 381 1,714 28 21 21 1--5 7-Landing 36 251 0 251 861 14 14 14 1--5 8-Stairs 44 748 0 748 1,493 25 41 41 1--5 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 5 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size Reg Size System 1 Supply Runouts Zone 1 1-Closet Built-In 0 750 0.01 0.1 28.8 15 4 4 1--5 2-Bedr4oom Built-In 0 750 0.01 0.1 244.9 29 33 33 1--5 3-Desk Built-In 0 750 0.01 0.1 75.9 10 10 10 1--5 4-Bath/Laundry Built-In 0 750 0.01 0.1 101 30 14 14 1--5 5-Living Room Built-In 0 750 0.01 0.1 466.9 63 92 92 1--6 6-Kitchen Built-In 0 750 0.01 0.1 152.3 28 21 21 1--5 7-Landing Built-In 0 750 0.01 0.1 100.5 14 14 14 1--5 8-Stairs Built-In 0 750 0.01 0.1 298.8 25 41 41 1--5 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 587.1 214 228 228 7x8 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:214 Cooling Flow:228 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 6 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-6-d: Glazing-Double pane low-e (e = 0.20 or less), high performance, sliding glass door, e=0.05 on surface 2, any frame, U-value 0.31, SHGC 0.31 137 2,887 0 2,432 2,432 12F-0bw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, brick finish, wood studs, U-value 0.065 699 3,090 0 210 210 16C-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-50 insulation, U- value 0.02 699 952 0 475 475 20P-38: Floor-Over open crawl space or garage, Passive, R-38 blanket insulation, any cover, U-value 0.03 699 1,426 0 83 83 Subtotals for structure:8,355 0 3,200 3,200 People:0 0 0 0 Equipment:0 0 0 Lighting:0 0 0 Ductwork:4,488 -138 1,153 1,014 Infiltration: Winter CFM: 16, Summer CFM: 0 974 0 0 0 Ventilation: Winter CFM: 12, Summer CFM: 12 736 -142 152 10 Humidification (Winter) 1.96 gal/day :719 0 0 0 Total Building Load Totals:15,271 -280 4,504 4,224 Check Figures Total Building Supply CFM:228 CFM Per Square ft.:0.327 Square ft. of Room Area:699 Square ft. Per Ton:1,986 Volume (ft³):5,592 Building Loads Total Heating Required Including Ventilation Air:20,094 Btuh 20.094 MBH (Based On 0.760 Derating) Total Sensible Gain:4,504 Btuh 100 % Total Latent Gain:-280 Btuh 0 % Total Cooling Required Including Ventilation Air:4,504 Btuh 0.38 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 7 System 1 Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-6-d: Glazing-Double pane low-e (e = 0.20 or less), high performance, sliding glass door, e=0.05 on surface 2, any frame, U-value 0.31, SHGC 0.31 137 2,887 0 2,432 2,432 12F-0bw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, brick finish, wood studs, U-value 0.065 699 3,090 0 210 210 16C-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-50 insulation, U- value 0.02 699 952 0 475 475 20P-38: Floor-Over open crawl space or garage, Passive, R-38 blanket insulation, any cover, U-value 0.03 699 1,426 0 83 83 Subtotals for structure:8,355 0 3,200 3,200 People:0 0 0 0 Equipment:0 0 0 Lighting:0 0 0 Ductwork:4,488 -138 1,153 1,014 Infiltration: Winter CFM: 16, Summer CFM: 0 974 0 0 0 Ventilation: Winter CFM: 12, Summer CFM: 12 736 -142 152 10 Humidification (Winter) 1.96 gal/day :719 0 0 0 System 1 Load Totals:15,271 -280 4,504 4,224 Check Figures Supply CFM:228 CFM Per Square ft.:0.327 Square ft. of Room Area:699 Square ft. Per Ton:1,986 Volume (ft³):5,592 System Loads Total Heating Required Including Ventilation Air:20,094 Btuh 20.094 MBH (Based On 0.760 Derating) Total Sensible Gain:4,504 Btuh 100 % Total Latent Gain:-280 Btuh 0 % Total Cooling Required Including Ventilation Air:4,504 Btuh 0.38 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 8 Equipment Data - System 1 Heating System Type:Natural Gas Furnace Model:GMEC960302BNA Tradename:Kenmore Manufacturer:GOODMAN MANUFACTURING COMPANY Description:Natural Gas or Propane Furnace Comment:2 stage Capacity:28,800 Efficiency:96 AFUE C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 9 Manual S Performance Data - System 1 Loads and Design Conditions Cooling: Outdoor Dry Bulb:0 Sensible Gain:4.504 Outdoor Wet Bulb:62 Latent Gain:-0.280 Indoor Dry Bulb:75 Total Gain:4.224 Indoor RH:50 Load SHR:1.07 Supply Airflow:0 Entering Dry Bulb:0 Entering Wet Bulb:0 Heating: Outdoor Dry Bulb:4 Sensible Loss:15.271 Indoor Dry Bulb:72 Entering Dry Bulb:64.4 Indoor RH:30 Supply Airflow:214 Equipment Performance Data at System Design Conditions Cooling: Model Type: Standard Air Conditioner, Manufacturer: Interpolation Results: Percent Load of Load Sensible Capacity:0.000 4.504 0% Latent Capacity:0.000 -0.280 0% Total Capacity:0.000 4.224 0% Heating: Model Type: Natural Gas Furnace, Model: GMEC960302BNA, Nominal Capacity: 28.800, Manufacturer: GOODMAN MANUFACTURING COMPANY Results: Percent Load of Load Heating Capacity:28.800 15.271 189% C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 10 Detailed Room Loads - Room 1 - Closet (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:4.0 ft.System Number:1 Room Width:8.0 ft.Zone Number:1 Area:32.0 sq.ft.Supply Air:4 CFM Ceiling Height:8.0 ft.Supply Air Changes:0.9 AC/hr Volume:256 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:1 CFM Runout Air:4 CFM Percent of Supply.:21 % Runout Duct Size:5 in.Actual Summer Vent.:0 CFM Runout Air Velocity:29 ft./min.Percent of Supply:5 % Runout Air Velocity:29 ft./min.Actual Winter Infil.:2 CFM Actual Loss:0.001 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0bw 8 X 8 64 0.065 4.4 283 0.3 0 19 W -Wall-12F-0bw 4 X 8 32 0.065 4.4 141 0.3 0 10 UP-Ceil-16C-50 4 X 8 32 0.020 1.4 44 0.7 0 22 Floor-20P-38 8 X 4 32 0.030 2.0 65 0.1 0 4 Subtotals for Structure:533 0 55 Infil.: Win.: 1.8, Sum.: 0.0 96 1.167 112 0.000 0 0 Ductwork:255 17 Room Totals:900 0 72 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 11 Detailed Room Loads - Room 2 - Bedr4oom (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:12.0 ft.System Number:1 Room Width:11.0 ft.Zone Number:1 Area:132.0 sq.ft.Supply Air:33 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.9 AC/hr Volume:1,056 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:2 CFM Runout Air:33 CFM Percent of Supply.:5 % Runout Duct Size:5 in.Actual Summer Vent.:2 CFM Runout Air Velocity:245 ft./min.Percent of Supply:5 % Runout Air Velocity:245 ft./min.Actual Winter Infil.:2 CFM Actual Loss:0.043 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0bw 11 X 8 68 0.065 4.4 301 0.3 0 20 S -Gls-4A-6-d shgc-0.31 0%S 20 0.310 21.1 422 17.1 0 342 UP-Ceil-16C-50 12 X 11 132 0.020 1.4 180 0.7 0 90 Floor-20P-38 11 X 12 132 0.030 2.0 269 0.1 0 16 Subtotals for Structure:1,172 0 468 Infil.: Win.: 1.6, Sum.: 0.0 88 1.170 103 0.000 0 0 Ductwork:505 145 Room Totals:1,780 0 613 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 12 Detailed Room Loads - Room 3 - Desk (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:11.0 ft.System Number:1 Room Width:4.0 ft.Zone Number:1 Area:44.0 sq.ft.Supply Air:10 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.8 AC/hr Volume:352 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:1 CFM Runout Air:10 CFM Percent of Supply.:5 % Runout Duct Size:5 in.Actual Summer Vent.:1 CFM Runout Air Velocity:76 ft./min.Percent of Supply:5 % Runout Air Velocity:76 ft./min.Actual Winter Infil.:1 CFM Actual Loss:0.005 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0bw 4 X 8 26 0.065 4.4 115 0.3 0 8 S -Gls-4A-6-d shgc-0.31 0%S 6 0.310 21.1 126 17.0 0 102 UP-Ceil-16C-50 11 X 4 44 0.020 1.4 60 0.7 0 30 Floor-20P-38 4 X 11 44 0.030 2.0 90 0.1 0 5 Subtotals for Structure:391 0 145 Infil.: Win.: 0.6, Sum.: 0.0 32 1.156 37 0.000 0 0 Ductwork:169 45 Room Totals:597 0 190 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 13 Detailed Room Loads - Room 4 - Bath/Laundry (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:11.0 ft.System Number:1 Room Width:9.0 ft.Zone Number:1 Area:99.0 sq.ft.Supply Air:14 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.0 AC/hr Volume:792 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:2 CFM Runout Air:14 CFM Percent of Supply.:12 % Runout Duct Size:5 in.Actual Summer Vent.:1 CFM Runout Air Velocity:101 ft./min.Percent of Supply:5 % Runout Air Velocity:101 ft./min.Actual Winter Infil.:3 CFM Actual Loss:0.008 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain S -Wall-12F-0bw 9 X 8 68 0.065 4.4 301 0.3 0 20 E -Wall-12F-0bw 11 X 8 88 0.065 4.4 389 0.3 0 26 S -Gls-4A-6-d shgc-0.31 0%S 4 0.310 21.1 84 17.0 0 68 UP-Ceil-16C-50 11 X 9 99 0.020 1.4 135 0.7 0 67 Floor-20P-38 9 X 11 99 0.030 2.0 202 0.1 0 12 Subtotals for Structure:1,111 0 193 Infil.: Win.: 3.0, Sum.: 0.0 160 1.163 186 0.000 0 0 Ductwork:513 60 Room Totals:1,810 0 253 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 14 Detailed Room Loads - Room 5 - Living Room (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:13.0 ft.System Number:1 Room Width:13.0 ft.Zone Number:1 Area:169.0 sq.ft.Supply Air:92 CFM Ceiling Height:8.0 ft.Supply Air Changes:4.1 AC/hr Volume:1,352 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:4 CFM Runout Air:92 CFM Percent of Supply.:4 % Runout Duct Size:6 in.Actual Summer Vent.:5 CFM Runout Air Velocity:467 ft./min.Percent of Supply:5 % Runout Air Velocity:467 ft./min.Actual Winter Infil.:4 CFM Actual Loss:0.118 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0bw 13 X 8 62 0.065 4.4 274 0.3 0 19 E -Wall-12F-0bw 13 X 8 84 0.065 4.4 371 0.3 0 25 N -Gls-4A-6-d shgc-0.31 100%S 42 0.310 21.1 885 10.3 0 434 E -Gls-4A-6-d shgc-0.31 0%S 20 0.310 21.1 422 33.6 0 672 UP-Ceil-16C-50 13 X 13 169 0.020 1.4 230 0.7 0 115 Floor-20P-38 13 X 13 169 0.030 2.0 345 0.1 0 20 Subtotals for Structure:2,527 0 1,285 Infil.: Win.: 3.9, Sum.: 0.0 208 1.163 242 0.000 0 0 Ductwork:1,096 397 Room Totals:3,865 0 1,682 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 15 Detailed Room Loads - Room 6 - Kitchen (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:13.0 ft.System Number:1 Room Width:11.0 ft.Zone Number:1 Area:143.0 sq.ft.Supply Air:21 CFM Ceiling Height:8.0 ft.Supply Air Changes:1.1 AC/hr Volume:1,144 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:2 CFM Runout Air:21 CFM Percent of Supply.:7 % Runout Duct Size:5 in.Actual Summer Vent.:1 CFM Runout Air Velocity:152 ft./min.Percent of Supply:5 % Runout Air Velocity:152 ft./min.Actual Winter Infil.:2 CFM Actual Loss:0.017 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0bw 11 X 8 73 0.065 4.4 323 0.3 0 22 N -Gls-4A-6-d shgc-0.31 100%S 15 0.310 21.1 316 10.3 0 155 UP-Ceil-16C-50 13 X 11 143 0.020 1.4 194 0.7 0 97 Floor-20P-38 11 X 13 143 0.030 2.0 292 0.1 0 17 Subtotals for Structure:1,125 0 291 Infil.: Win.: 1.6, Sum.: 0.0 88 1.170 103 0.000 0 0 Ductwork:486 90 Room Totals:1,714 0 381 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 16 Detailed Room Loads - Room 7 - Landing (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:6.0 ft.System Number:1 Room Width:6.0 ft.Zone Number:1 Area:36.0 sq.ft.Supply Air:14 CFM Ceiling Height:8.0 ft.Supply Air Changes:2.9 AC/hr Volume:288 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:1 CFM Runout Air:14 CFM Percent of Supply.:6 % Runout Duct Size:5 in.Actual Summer Vent.:1 CFM Runout Air Velocity:100 ft./min.Percent of Supply:5 % Runout Air Velocity:100 ft./min.Actual Winter Infil.:1 CFM Actual Loss:0.008 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0bw 5.5 X 8 29 0.065 4.4 128 0.3 0 9 N -Gls-4A-6-d shgc-0.31 100%S 15 0.310 21.1 316 10.3 0 155 UP-Ceil-16C-50 6 X 6 36 0.020 1.4 49 0.7 0 24 Floor-20P-38 6 X 6 36 0.030 2.0 73 0.1 0 4 Subtotals for Structure:566 0 192 Infil.: Win.: 0.8, Sum.: 0.0 44 1.159 51 0.000 0 0 Ductwork:244 59 Room Totals:861 0 251 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 17 Detailed Room Loads - Room 8 - Stairs (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:11.0 ft.System Number:1 Room Width:4.0 ft.Zone Number:1 Area:44.0 sq.ft.Supply Air:41 CFM Ceiling Height:8.0 ft.Supply Air Changes:6.9 AC/hr Volume:352 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:1 CFM Runout Air:41 CFM Percent of Supply.:3 % Runout Duct Size:5 in.Actual Summer Vent.:2 CFM Runout Air Velocity:299 ft./min.Percent of Supply:5 % Runout Air Velocity:299 ft./min.Actual Winter Infil.:2 CFM Actual Loss:0.063 in.wg./100 ft.Actual Summer Infil.:0 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain W -Wall-12F-0bw 11 X 8 73 0.065 4.4 323 0.3 0 22 N -Wall-12F-0bw 4 X 8 32 0.065 4.4 141 0.3 0 10 W -Gls-4A-6-d shgc-0.31 0%S 15 0.310 21.1 316 33.6 0 504 UP-Ceil-16C-50 11 X 4 44 0.020 1.4 60 0.7 0 30 Floor-20P-38 4 X 11 44 0.030 2.0 90 0.1 0 5 Subtotals for Structure:930 0 571 Infil.: Win.: 2.2, Sum.: 0.0 120 1.167 140 0.000 0 0 Ductwork:423 177 Room Totals:1,493 0 748 C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Air-City Heating & A/C LLC Gillam Addition Loveland, CO 80538 Page 18 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Closet 32 900 15 1-5 29 72 0 4 4 2 Bedr4oom 132 1,780 29 1-5 245 613 0 33 33 3 Desk 44 597 10 1-5 76 190 0 10 10 4 Bath/Laundry 99 1,810 30 1-5 101 253 0 14 14 5 Living Room 169 3,865 63 1-6 467 1,682 0 92 92 6 Kitchen 143 1,714 28 1-5 152 381 0 21 21 7 Landing 36 861 14 1-5 100 251 0 14 14 8 Stairs 44 1,493 25 1-5 299 748 0 41 41 Ventilation 736 152 -142 Humidification 719 Duct Latent -60 Return Duct 796 163 -78 System 1 total 699 15,271 214 4,504 -280 228 228 System 1 Main Trunk Size:7x8 in. Velocity:587 ft./min Loss per 100 ft.:0.097 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:0.38 107% / -7%4,504 -280 4,504 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:GMEC960302BNA Indoor Model: Brand:Kenmore Description:Natural Gas or Propane Furnace Efficiency:96 AFUE 0 SEER Comment :2 stage Sound:0 0 Capacity:28,800 Btuh 0 Btuh Sensible Capacity:n/a 0 Btuh Latent Capacity:n/a 0 Btuh C:\ ...\Gallam Addition.rh9 Friday, July 9, 2021, 5:15 PM Reviewed by SAFEbuilt 07/27/2021 Residential Plans Examiner Review Form for HVAC System Design (Loads, Equipment, Ducts) Form RPER 1.01 8 Mar 10 County, Town, Municipality, Jurisdiction Header Information Contractor Mechanical License # Building Plan # Home Address (Street or Lot#, Block, Subdivision) REQUIRED ATTACHMENTS¹ Manual J1 Form (and supporting worksheets): or MJ1AE Form² (and supporting worksheets): OEM performance data (heating, cooling, blower): Manual D Friction Rate Worksheet: Duct distribution system sketch: ATTACHED Yes No Yes No Yes No Yes No Yes No HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Winter Design Conditions Outdoor temperature 4 °F Indoor temperature 72 °F Total heat loss 15271 Btu/h Summer Design Conditions Outdoor temperature 89 °F Indoor temperature 75 °F Grains difference -21 Gr @ 50 % Rh Sensible heat gain 4504 Btu/h Latent heat gain -280 Btu/h Total heat gain 4224 Btu/h Building Construction Information Building Orientation (Front door faces)North North, East, West, South, Northeast, Northwest, Southeast, Southwest Number of bedrooms 1 Conditioned floor area 699 Sq Ft Number of occupants 0 Windows Eave overhang depth 0 Ft Internal shade Blinds, drapes, etc Number of skylights 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Equipment type Furnace Furnace, Heat pump, Boiler, etc. Model GMEC960302BNA Heating output capacity 28800 Btu/h Heat pumps - capacity at winter design outdoor conditions Auxiliary heat output capacity Btu/h Cooling Equipment Data Equipment type Standard Air Conditioner Air Conditioner, Heat pump, etc Model Sensible cooling capacity Btu/h Latent cooling capacity Btu/h Total cooling capacity Btu/h Blower Data Heating CFM 228 CFM Cooling CFM 228 CFM HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow CFM External Static Pressure (ESP)IWC Component Pressure Losses (CPL)IWC Available Static Pressure (ASP)IWC ASP = ESP - CPL Longest supply duct:Ft Longest return duct:Ft Total Effective Length (TEL)Ft Friction Rate:IWC Friction Rate = (ASP × 100) ÷ TEL Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, Lined sheet metal, Other (specify) Branch Duct: Duct board, Flex, Sheet metal, Lined sheet metal, Other (specify) I declare the load calculation, equipment selection, and duct system design were rigorously performed based on the building plan listed above, I understand the claims made on these forms will be subject to review and verification. Contractor's Printed Name Date Contractor's Signature Reserved for use by County, Town, Municipality, or Authority having jurisdiction. ¹ The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ² If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. Reviewed by SAFEbuilt 07/27/2021 Residential Plans Examiner Review Form for HVAC System Design (Loads, Equipment, Ducts) Form RPER 1.01 8 Mar 10 County, Town, Municipality, Jurisdiction Header Information Contractor Mechanical License # Building Plan # Home Address (Street or Lot#, Block, Subdivision) REQUIRED ATTACHMENTS¹ Manual J1 Form (and supporting worksheets): or MJ1AE Form² (and supporting worksheets): OEM performance data (heating, cooling, blower): Manual D Friction Rate Worksheet: Duct distribution system sketch: ATTACHED Yes No Yes No Yes No Yes No Yes No HVAC LOAD CALCULATION (UMC 1106.1) Design Conditions Winter Design Conditions Outdoor temperature 4 °F Indoor temperature 72 °F Total heat loss 15271 Btu/h Summer Design Conditions Outdoor temperature 89 °F Indoor temperature 75 °F Grains difference -21 Gr @ 50 % Rh Sensible heat gain 4504 Btu/h Latent heat gain -280 Btu/h Total heat gain 4224 Btu/h Building Construction Information Building Orientation (Front door faces)North North, East, West, South, Northeast, Northwest, Southeast, Southwest Number of bedrooms 1 Conditioned floor area 699 Sq Ft Number of occupants 0 Windows Eave overhang depth 0 Ft Internal shade Blinds, drapes, etc Number of skylights 0 HVAC EQUIPMENT SELECTION Heating Equipment Data Equipment type Furnace Furnace, Heat pump, Boiler, etc. Model GMEC960302BNA Heating output capacity 28800 Btu/h Heat pumps - capacity at winter design outdoor conditions Auxiliary heat output capacity Btu/h Cooling Equipment Data Equipment type Standard Air Conditioner Air Conditioner, Heat pump, etc Model Sensible cooling capacity Btu/h Latent cooling capacity Btu/h Total cooling capacity Btu/h Blower Data Heating CFM 228 CFM Cooling CFM 228 CFM HVAC DUCT DISTRIBUTION SYSTEM DESIGN (UMC 601.2) Design airflow CFM External Static Pressure (ESP)IWC Component Pressure Losses (CPL)IWC Available Static Pressure (ASP)IWC ASP = ESP - CPL Longest supply duct:Ft Longest return duct:Ft Total Effective Length (TEL)Ft Friction Rate:IWC Friction Rate = (ASP × 100) ÷ TEL Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, Lined sheet metal, Other (specify) Branch Duct: Duct board, Flex, Sheet metal, Lined sheet metal, Other (specify) I declare the load calculation, equipment selection, and duct system design were rigorously performed based on the building plan listed above, I understand the claims made on these forms will be subject to review and verification. Contractor's Printed Name Date Contractor's Signature Reserved for use by County, Town, Municipality, or Authority having jurisdiction. ¹ The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ² If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. Reviewed by SAFEbuilt 07/27/2021 SS-GMEC96 www.goodmanmfg.com 10/17 Supersedes 9/17 * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. Standard Features Cabinet Features • Energy-efficient, multi-speed ECM blower motor • Heavy-duty, aluminized-steel tubular heat exchanger • Stainless-steel secondary heat exchanger • Two-stage gas valve provides quiet, economical heating • Durable Silicon Nitride igniter • Quiet two-speed induced draft blower • Self-diagnostic control board with constant memory fault code history output to a LED • Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier • Low continuous fan speed options offer quiet air circulation • All models comply with California 40 ng/J Low NOx emissions standard • AHRI Certified; ETL Listed • Designed for multi-position installation — upflow, horizontal left or right • Certified for direct vent (2-pipe) or non-direct vent (1-pipe) • Easy-to-install top venting with optional side venting • Convenient left or right connection for gas and electrical service • Cabinet air leakage (QLeak) ≤ 2% • Heavy-gauge steel cabinet with durable finish • Fully insulated heat exchanger and blower section • Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications Contents Nomenclature ........................................2 Product Specifications ...........................3 Dimensions ............................................4 Airflow Specifications ............................5 Wiring Diagrams ..................................16 Accessories ..........................................20 Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE GMEC96 Heating Input: 30,000–120,000 BTU/h Reviewed by SAFEbuilt 07/27/2021 2 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 3 Nomenclature G M E C 96 060 3 B N ** 1 2 3 4 5,6 7,8,9 10 11 12 13,14 Brand Engineering G - Goodman® Brand Major / Minor Revisions * Not used for inventory control. Configuration NOx M - Upflow/Horizontal N - Low NOx C - Downflow/Horizontal Cabinet Width Motor A - 14” C - 21" V - Variable Speed ECM / ComfortNet B - 17½” D - 24½" E - Multi-Speed ECM S - Single Speed Maximum CFM 2 - 800 CFM 4 - 1600 CFM Gas Valve 3 - 1200 CFM 5 - 2000 CFM M - Modulating C - Two- Stage MBTU/h S - Single Stage 040 - 40,000 BTU/h 060 - 60,000 BTU/h AFUE 120 - 120,000 BTU/h 97 - 97% AFUE 96 - 96% AFUE 92 - 92% AFUE Reviewed by SAFEbuilt 07/27/2021 2www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 3 Product Specifications GMEC96 0303ANA GMEC96 0403ANA GMEC96 0603ANA GMEC96 0302BNA GMEC96 0402BNA GMEC96 0603BNA GMEC96 0803BNA GMEC96 0804CNA GMEC96 1004CNA GMEC96 1005CNA GMEC96 1205DNA Heating Data High Fire Input¹30,000 40,000 60,000 30,000 40,000 60,000 80,000 80,000 100,000 100,000 120,000 High Fire Output¹28,800 38,400 57,600 28,800 38,400 57,600 76,800 76,800 96,000 96,000 115,200 Low-Fire Input¹21,000 28,000 42,000 21,000 28,000 42,000 56,000 56,000 70,000 70,000 84,000 Low-Fire Output¹20,160 26,880 40,320 20,160 26,880 40,320 53,760 53,760 67,200 67,200 80,640 AFUE²96 96 96 96 96 96 96 96 96 96 96 Temp. Rise Range (°F)20 - 50 20 - 50 30 - 60 20 - 50 20 - 50 20 - 50 35 - 65 25 - 55 35 - 65 35 - 65 35 - 65 Vent Diameter³2" - 3"2" - 3"2" - 3"2" - 3"2" - 3"2" - 3"2" - 3"2" - 3"2" - 3"2" - 3"2" - 3" No. of Burners 2 2 3 2 2 3 4 4 5 5 6 Circulator Blower Available AC @ 0.5" ESP 1.5 - 2 1.5 - 3 1.5 - 3 1.5 - 2 1.5 - 3 1.5 - 3 1.5 - 3 2.5 - 4 1.5 - 4 3 - 5 3 - 5 Size (D x W)11" x 6"11” x 6”11” x 6”10" x 8"10" x 8"11" x 8"11" x 8"11" x 10"11" x 10"11" x 10"11" x 11" Horsepower @ 1075 RPM 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 1 1 1 Speed 5 5 5 5 5 5 5 5 5 5 5 Filter Size (in²) (Qty) (1) 16 x 25 (side) or (1) 14 x 25 (bottom) (1) 16 x 25 (side) or (1) 14 x 25 (bottom) (1) 16 x 25 (side) or (1) 14 x 25 (bottom) (1) 16 x 25 (side or bottom) (1) 16 x 25 (side or bottom) (1) 16 x 25 (side or bottom) (1) 16 x 25 (side or bottom) (1) 16 x 25 (side or bottom) (1) 16 x 25 (side or bottom) (1) 20 x 25 (bottom) or (2) 16 x 25 (side) (1) 20 x 25 (bottom) or (2) 16 x 25 (side) Electrical Data Min. Circuit Ampacity⁴8.6 8.6 8.6 8 8 8 8 11.6 13.3 13.3 13.3 Max. Overcurrent (amps)⁵15 15 15 15 15 15 15 15 15 15 15 Shipping Weight (lbs)106 106 110 111 112 115 118 123 140 140 154 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. ⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. • For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Reviewed by SAFEbuilt 07/27/2021 4 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 5 Dimensions Air Discharge Air Return Model A B C D E GMEC960303ANA 14"12½”10½”8⅝”10⅛" GMEC960403ANA 14”12½”10½”8⅝”10⅛” GMEC960603ANA 14”12½”10½”8⅝”10⅛” GMEC960302BNA 17½"16"13⅞"12⅛"13⅝" GMEC960402BNA 17½"16"13⅞"12⅛"13⅝" GMEC960603BNA 17½"16"13⅞"12⅛"13⅝" GMEC960803BNA 17½”16”13⅞”12⅛”13⅝” GMEC960804CNA 21" 19½"17⅜"16"17½" GMEC961004CNA 21" 19½"17⅜"16"17½" GMEC961004CNA 21" 19½"17⅜"16"17½" GMEC961205DNA 24½ 23"20⅞"19⅜"20⅞" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0"0"3"C 0"1" Horizontal 6"0"3"C 0"6" C = If placed on combustible floor, the floor MUST be wood ONLY. 5 9¼ 19⅝ 34½ ¾ 19½ ⅞ ¾ B C 23 2⅜ 1⅞ 2 ½ 2 6½ 5 9 ¼ 19 ⅝ 23 24⅞ 31⅞ A 21⅛ 2 ⅝ 14 23 1 ½ 1 ⅜ ¾ 28 ¾ 2⅜ 1⅞ 2½ 2 2¾ 6 ½ 1⅞ 26½ 23½ Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW Condensate Drain Trap Exterior Connection (Right or Left Side) ¾ PVC Vent/ Flue Pipe 2" PVC Alternate Vent/ Flue Location Right-Side Drain Trap Exterior Holes High-Voltage Electrical Outlet AlternateGas Supply Low-Voltage Electrical Outlet Standard Gas Supply Location Center Dimple For Alternate Air Intake Pipe3" OD Hole Air Intake 2" Pipe Left-Side Drain Trap Exterior Holes High-Voltage Electrical Outlet Low-voltage Electrical Outlet Reviewed by SAFEbuilt 07/27/2021 4www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 5 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Minimum Filter Sizes GMEC96 0303ANA GMEC96 0403ANA GMEC96 0603ANA GMEC96 0302BNA GMEC96 0402BNA GMEC96 0603BNA GMEC96 0803BNA Filter Size (in²) (Qty)16 x 25 (side) or 14 x 25 bottom)(1) 16 x 25 (side or bottom) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. Minimum Filter Sizes GMEC96 1004CNA GMEC96 1205DNA Filter Size (in²) (Qty)(1) 16 x 25 (side or bottom) (1) 20 x 25 (bottom) or (2) 16 x 25 (side) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. Airflow Data — GMEC960303AN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 623 506 451 393 343 293 N/A N/A **OFF OFF OFF Ylo 914 874 841 805 772 732 696 657 Y 1070 1040 1005 975 942 915 883 849 ON OFF OFF Ylo 653 597 552 507 460 410 366 326 Y 914 874 841 805 772 732 696 657 ON ON OFF Ylo 653 597 552 507 460 410 366 326 Y 1070 1040 1005 975 942 915 883 849 OFF ON ON Ylo 653 597 552 507 460 410 366 326 Y 623 506 451 393 343 293 N/A N/A ON OFF ON Ylo 755 710 672 627 582 534 491 447 Y 1070 1040 1005 975 942 915 883 849 ON ON ON Ylo 755 710 672 627 582 534 491 447 Y 653 597 552 507 460 410 366 326 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 623 42 506 N/A 451 N/A 393 N/A 343 N/A 293 N/A N/A W2 755 35 710 37 672 42 627 45 582 49 534 491 447 ON OFF W1 653 40 597 44 552 47 507 N/A 460 N/A 410 366 326 W2 755 35 710 37 672 42 627 45 582 49 534 491 447 ON ON W1 653 40 597 44 552 47 507 N/A 460 N/A 410 366 326 W2 914 28 874 30 841 31 805 32 772 34 732 696 657 OFF ON W1 914 28 874 30 841 31 805 32 772 34 732 696 657 W2 1070 25 1040 25 1005 26 975 27 942 28 915 883 849 ** Factory Default Reviewed by SAFEbuilt 07/27/2021 6 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 7 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Airflow Data — GMEC960403AN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 721 679 635 591 552 505 463 422 **OFF OFF OFF Ylo 914 874 841 805 772 732 696 657 Y 1070 1040 1005 975 942 915 883 849 ON OFF OFF Ylo 653 597 552 507 460 410 366 326 Y 914 874 841 805 772 732 696 657 ON ON OFF Ylo 653 597 552 507 460 410 366 326 Y 1070 1040 1005 975 942 915 883 849 OFF OFF ON Ylo 914 874 841 805 772 732 696 657 Y 1191 1168 1135 1112 1081 1055 1024 998 OFF ON ON Ylo 653 597 552 507 460 410 366 326 Y 721 679 635 591 552 505 463 422 ON OFF ON Ylo 1191 1168 1135 1112 1081 1055 1024 998 Y 1091 1061 1026 996 962 936 903 869 ON ON ON Ylo 1191 1168 1135 1112 1081 1055 1024 998 Y 653 597 552 507 460 410 366 326 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 721 48 679 N/A 635 N/A 591 N/A 552 N/A 505 463 422 W2 1191 29 1168 30 1135 31 1112 31 1081 32 1055 1024 998 ON OFF W1 653 N/A 597 N/A 552 N/A 507 N/A 460 N/A 410 366 326 W2 1191 29 1168 30 1135 31 1112 31 1081 32 1055 1024 998 ON ON W1 653 N/A 597 N/A 552 N/A 507 N/A 460 N/A 410 366 326 W2 914 38 874 40 841 41 805 43 772 45 732 696 657 OFF ON W1 914 38 874 40 841 41 805 43 772 45 732 696 657 W2 1070 33 1040 34 1005 35 975 36 942 37 915 883 849 ** Factory Default Reviewed by SAFEbuilt 07/27/2021 6www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 7 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Airflow Data — GMEC960603AN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 1254 1230 1199 1171 1139 1115 1086 1053 **OFF OFF OFF Ylo 880 838 794 763 722 689 644 606 Y 1056 1026 991 961 929 894 864 829 ON OFF OFF Ylo 697 654 600 557 508 460 419 371 Y 880 838 794 763 722 689 644 606 ON ON OFF Ylo 697 654 600 557 508 460 419 371 Y 1056 1026 991 961 929 894 864 829 OFF OFF ON Ylo 880 838 794 763 722 689 644 606 Y 1330 1301 1274 1244 1227 1191 1163 1132 OFF ON ON Ylo 697 654 600 557 508 460 419 371 Y 1254 1230 1199 1171 1139 1115 1086 1053 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 1254 42 1230 42 1199 43 1171 44 1139 46 1115 1086 1053 W2 1330 39 1301 39 1274 41 1244 42 1227 42 1191 1163 1132 ON OFF W1 697 N/A 654 N/A 600 N/A 557 N/A 508 N/A 460 419 371 W2 1330 39 1301 39 1274 41 1244 42 1227 42 1191 1163 1132 ON ON W1 697 N/A 654 N/A 600 N/A 557 N/A 508 N/A 460 419 371 W2 880 N/A 838 N/A 794 N/A 763 N/A 722 N/A 689 644 606 OFF ON W1 880 N/A 838 N/A 794 N/A 763 N/A 722 N/A 689 644 606 W2 1056 49 1026 51 997 52 961 54 929 56 894 864 829 ** Factory Default Reviewed by SAFEbuilt 07/27/2021 8 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 9 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Airflow Data — GMEC960302BN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 870 658 548 469 413 349 293 N/A **OFF OFF OFF Ylo 874 697 612 533 470 414 361 303 Y 1146 1097 1049 1002 941 895 846 787 ON OFF OFF Ylo 874 697 612 533 470 414 361 303 Y 928 868 810 743 670 614 560 505 ON ON OFF Ylo 928 868 810 743 670 614 560 505 Y 1146 1097 1049 1002 941 895 846 787 OFF ON ON Ylo 874 697 612 533 470 414 361 303 Y 1146 1097 1049 1002 941 895 846 787 ON OFF ON Ylo 885 821 755 684 621 557 508 461 Y 1146 1097 1049 1002 941 895 846 787 ON ON ON Ylo 885 821 755 684 621 557 508 461 Y 874 697 612 533 470 414 361 303 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 870 21 658 28 548 34 469 40 413 45 349 293 N/A W2 885 30 821 32 755 35 684 39 621 43 557 508 461 ON OFF W1 874 21 697 27 612 31 533 35 470 40 414 361 303 W2 885 30 821 32 755 35 684 39 621 43 557 508 461 ON ON W1 874 21 697 27 612 31 533 35 470 40 414 361 303 W2 928 29 868 31 810 33 743 36 670 40 614 560 505 OFF ON W1 928 20 868 22 810 23 743 25 670 28 614 560 505 W2 1146 23 1097 24 1049 25 1002 27 941 28 895 846 787 ** Factory Default Reviewed by SAFEbuilt 07/27/2021 8www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 9 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Airflow Data — GMEC960402BN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 847 694 611 535 471 415 357 313 **OFF OFF OFF Ylo 856 667 546 466 413 357 302 N/A Y 1143 1095 1046 996 946 890 834 778 ON OFF OFF Ylo 856 667 546 466 413 357 302 N/A Y 960 898 840 780 711 659 596 547 ON ON OFF Ylo 960 898 840 780 711 659 596 547 Y 1143 1095 1046 996 946 890 834 778 OFF OFF ON Ylo 960 898 840 780 711 659 596 547 Y 989 932 882 819 773 695 650 586 OFF ON ON Ylo 856 667 546 466 413 357 302 N/A Y 1143 1095 1046 996 946 890 834 778 ON OFF ON Ylo 989 932 882 819 773 695 650 586 Y 1143 1095 1046 996 946 890 834 778 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 847 29 694 36 611 41 535 47 471 53 415 357 313 W2 989 36 932 38 882 40 819 43 773 46 695 650 586 ON OFF W1 856 29 667 37 546 46 466 53 413 N/A 357 302 N/A W2 989 36 932 38 882 40 819 43 773 46 695 650 586 ON ON W1 856 29 667 37 546 46 466 53 413 N/A 357 302 N/A W2 960 37 898 40 840 42 780 46 711 50 659 596 547 OFF ON W1 960 26 898 28 840 30 780 32 711 35 659 596 547 W2 1143 31 1095 32 1046 34 996 36 946 38 890 834 778 ** Factory Default Reviewed by SAFEbuilt 07/27/2021 10 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 11 Airflow Data — GMEC960603BN Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 894 846 780 720 660 603 554 505 **OFF OFF OFF Ylo 782 629 547 469 396 333 N/A N/A Y 1236 1189 1149 1101 1066 1017 969 928 ON OFF OFF Ylo 782 629 547 469 396 333 N/A N/A Y 1149 1104 1057 1017 963 918 865 822 ON ON OFF Ylo 1149 1104 1057 1017 963 918 865 822 Y 1236 1189 1149 1101 1066 1017 969 928 OFF OFF ON Ylo 1149 1104 1057 1017 963 918 865 822 Y 1328 1287 1249 1215 1170 1131 1085 1046 OFF ON ON Ylo 782 629 547 469 396 333 N/A N/A Y 1236 1189 1149 1101 1066 1017 969 928 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 894 41 846 44 780 47 720 51 660 56 603 554 505 W2 1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046 ON OFF W1 782 47 629 59 547 N/A 469 N/A 396 N/A N/A N/A N/A W2 1328 40 1287 41 1249 42 1215 43 1170 45 1131 1085 1046 ON ON W1 782 47 629 59 547 N/A 469 N/A 396 N/A N/A N/A N/A W2 1149 46 1104 48 1057 50 1017 52 963 55 918 865 822 OFF ON W1 1149 32 1104 33 1057 35 1017 36 963 38 918 865 822 W2 1236 43 1189 44 1149 46 1101 48 1066 50 1017 969 928 ** Factory Default Reviewed by SAFEbuilt 07/27/2021 10www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 11 Airflow Data — GMEC960803BN Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 1221 1172 1128 1087 1049 1005 959 922 **OFF OFF OFF Ylo 750 644 569 507 442 388 328 N/A Y 1111 1068 1025 984 941 885 N/A 801 ON OFF OFF Ylo 750 644 569 507 442 388 328 N/A Y 894 842 784 726 682 618 562 519 ON ON OFF Ylo 894 842 784 726 682 618 562 519 Y 1111 1068 1025 984 941 885 N/A 801 OFF ON OFF Ylo 894 842 784 726 682 618 562 519 Y 1221 1172 1128 1087 1049 1005 959 922 OFF OFF ON Ylo 894 842 784 726 682 618 562 519 Y 1311 1293 1249 1203 1172 1122 1088 1041 OFF ON ON Ylo 750 644 569 507 442 388 328 N/A Y 1111 1068 1025 984 941 885 N/A 801 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 1221 40 1172 42 1128 44 1087 45 1049 47 1005 959 922 W2 1311 54 1293 54 1249 56 1203 58 1172 60 1122 1088 1041 ON OFF*W1 750 66 644 N/A 569 N/A 507 N/A 442 N/A 388 328 N/A W2 1311 54 1293 54 1249 56 1203 58 1172 60 1122 1088 1041 ON ON*W1 750 66 644 N/A 569 N/A 507 N/A 442 N/A 388 328 N/A W2 894 N/A 842 N/A 784 N/A 726 N/A 682 N/A 618 562 519 OFF ON W1 894 55 842 59 784 63 726 68 682 N/A 618 562 519 W2 1111 63 1068 66 1025 69 984 72 941 75 885 N/A 801 * NOT RECOMMENDED ** Factory Default Reviewed by SAFEbuilt 07/27/2021 12 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 13 Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Airflow Data — GMEC960804CN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 1281 1220 1152 1096 1031 978 914 856 **OFF OFF OFF Ylo 1408 1337 1279 1218 1167 1112 1062 999 Y 1727 1691 1642 1600 1545 1504 1449 1410 ON ON OFF Ylo 1185 1121 1058 992 933 868 808 750 Y 1727 1691 1642 1600 1545 1504 1449 1410 OFF ON OFF Ylo 1185 1121 1058 992 933 868 808 750 Y 1281 1220 1152 1096 1031 978 914 856 OFF OFF ON Ylo 1185 1121 1058 992 933 868 808 750 Y 1839 1790 1757 1699 1665 1615 1568 1527 OFF ON ON Ylo 1408 1337 1279 1218 1167 1112 1062 999 Y 1727 1691 1642 1600 1545 1504 1449 1410 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 1281 38 1220 40 1152 43 1096 45 1031 48 978 914 856 W2 1839 38 1790 39 1757 40 1699 41 1665 42 1615 1568 1527 ON OFF W1 1408 35 1337 37 1279 39 1218 40 1167 42 1112 1062 999 W2 1839 38 1790 39 1757 40 1699 41 1665 42 1615 1568 1527 ON ON*W1 1408 35 1337 37 1279 39 1218 40 1167 42 1112 1062 999 W2 1185 N/A 1121 N/A 1058 N/A 992 N/A 933 N/A 868 808 750 OFF ON W1 1185 42 1121 44 1058 47 992 50 933 53 868 808 519 W2 1727 41 1691 42 1642 43 1600 44 1545 46 1504 1449 1410 * NOT RECOMMENDED ** Factory Default Reviewed by SAFEbuilt 07/27/2021 12www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 13 Airflow Data — GMEC961004CN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 1522 1464 1402 1338 1280 1230 1167 1101 **OFF OFF OFF Ylo 1004 890 805 710 620 553 474 406 Y 1772 1713 1662 1609 1540 1498 1452 1399 ON OFF OFF Ylo 1004 890 805 710 620 553 474 406 Y 1312 1235 1170 1101 1037 962 880 820 ON ON OFF Ylo 1312 1235 1170 1101 1037 962 880 820 Y 1772 1713 1662 1609 1540 1498 1452 1399 OFF ON OFF Ylo 1312 1235 1170 1101 1037 962 880 820 Y 1522 1464 1402 1338 1280 1230 1167 1101 OFF OFF ON Ylo 1312 1235 1170 1101 1037 962 880 820 Y 1861 1803 1749 1698 1653 1594 1549 1504 OFF ON ON Ylo 1004 890 805 710 620 553 474 406 Y 1772 1713 1662 1609 1540 1498 1452 1399 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 1522 40 1464 42 1402 44 1338 46 1280 48 1230 1167 1101 W2 1861 47 1803 49 1749 50 1698 52 1653 53 1594 1549 1504 ON OFF W1 1004 61 890 69 805 N/A 710 N/A 620 N/A 553 474 406 W2 1861 47 1803 49 1749 50 1698 52 1653 53 1594 1549 1504 ON ON*W1 1004 61 890 69 805 N/A 710 N/A 620 N/A 553 474 406 W2 1312 67 1235 N/A 1170 N/A 1101 N/A 1037 N/A 962 880 820 OFF ON W1 1312 47 1235 50 1170 53 1101 56 1037 59 962 880 820 W2 1772 50 1713 51 1662 53 1609 55 1540 57 1498 1452 1399 * NOT RECOMMENDED ** Factory Default Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Reviewed by SAFEbuilt 07/27/2021 14 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 15 Airflow Data — GMEC961005CN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 1283 1219 1162 1101 1036 974 917 864 **OFF OFF OFF Ylo 1438 1366 1309 1254 1163 1133 1077 1013 Y 2008 1963 1964 1916 1876 1839 1801 1759 ON ON OFF Ylo 1384 1324 1271 1204 1145 1088 1029 985 Y 2008 1963 1964 1916 1876 1839 1801 1759 OFF OFF ON Ylo 1384 1324 1271 1204 1145 1088 1029 985 Y 1811 1772 1733 1690 1644 1590 1551 1492 OFF ON ON Ylo 1438 1366 1309 1254 1163 1133 1077 1013 Y 2008 1963 1964 1916 1876 1839 1801 1759 ON OFF ON Ylo 1811 1772 1733 1690 1644 1590 1551 1492 Y 2008 1963 1964 1916 1876 1839 1801 1759 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 1283 48 1219 51 1162 53 1101 56 1036 59 974 917 864 W2 1811 49 1772 50 1733 51 1690 52 1644 54 1590 1551 1492 ON OFF W1 1438 43 1366 45 1309 47 1254 49 1163 53 1133 1077 1013 W2 1811 49 1772 50 1733 51 1690 52 1644 54 1590 1551 1492 ON ON*W1 1438 43 1366 45 1309 47 1254 49 1163 53 1133 1077 1013 W2 1384 64 1324 N/A 1271 N/A 1204 N/A 1145 N/A 1088 1029 985 OFF ON W1 1384 44 1324 47 1271 48 1204 51 1145 54 1088 1029 985 W2 2008 44 1963 45 1964 45 1916 46 1876 47 1839 1801 1759 * NOT RECOMMENDED ** Factory Default Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Reviewed by SAFEbuilt 07/27/2021 14www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 15 Airflow Data — GMEC961205DN COOLING Dipswitch Setting: Switch Bank 2 Switch 1 2 3 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM CFM CFM CFM CFM CFM CFM CFM G 1796 1753 1697 1645 1589 1536 1478 1425 **OFF OFF OFF Ylo 1106 1017 946 855 764 681 605 N/A Y 1683 1628 1565 1511 1445 1387 1340 1276 ON OFF OFF Ylo 1106 1017 946 855 764 681 605 N/A Y 1399 1327 1259 1185 1118 1051 980 913 ON ON OFF Ylo 1399 1327 1259 1185 1118 1051 980 913 Y 1683 1628 1565 1511 1445 1387 1340 1276 OFF ON OFF Ylo 1399 1327 1259 1185 1118 1051 980 913 Y 1796 1753 1697 1645 1589 1536 1478 1425 OFF OFF ON Ylo 1399 1327 1259 1185 1118 1051 980 913 Y 2211 2162 2122 2076 2029 1986 1984 1942 OFF ON ON Ylo 1106 1017 946 855 764 681 605 N/A Y 1683 1628 1565 1511 1445 1387 1340 1276 ** Factory Default HEATING Dipswitch Setting: Switch Bank 3 Switch 1 2 Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM **OFF OFF W1 1796 41 1753 42 1697 44 1645 45 1589 47 1536 1478 1425 W2 2211 48 2162 49 2122 50 2076 51 2029 52 1986 1984 1942 ON OFF W1 1106 67 1017 73 946 N/A 855 N/A 764 N/A 681 605 N/A W2 2211 48 2162 49 2122 50 2076 51 2029 52 1986 1984 1942 ON ON*W1 1106 67 1017 73 946 N/A 855 N/A 764 N/A 681 605 N/A W2 1399 75 1327 N/A 1259 N/A 1185 N/A 1118 N/A 1051 980 913 OFF ON W1 1399 53 1327 56 1259 59 1185 62 1118 66 1051 980 913 W2 1683 63 1628 65 1565 67 1511 70 1445 73 1387 1340 1276 * NOT RECOMMENDED ** Factory Default Notes • All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. Reviewed by SAFEbuilt 07/27/2021 16 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 17 Temperature Rise Range Chart 30 4 0 5 0 6 0 7 0 8 0 9 0 11 0 1 2 0 10 0 13 0 1 4 0 1 5 0 10 0 90 80 70 60 50 40 30 20 10 OU T P U T B T U / H R x 1 0 0 0 BT U O U T P U T v s T E M P E R A T U R E R I S E C H A R T TEMPERATURE RISE 60 0 C F M 70 0 90 0 10 0 0 11 0 0 12 0 0 14 0 0 16 0 0 18 0 0 20 0 0 22 0 0 24 0 0 C F M FO R M U L A S BT U O U T P U T = C F M x 1 . 0 8 x R I S E RI S E = BT U O U T P U T 1. 0 8 ÷ C F M 80 0 Temperature Rise Ou t p u t B T U / h x 1 , 0 0 0 Fo r m u l a s BT U / h O u t p u t = C F M x 1 . 0 8 x R i s e Ri s e = BT U / H O u t p u t CF M x 1 . 0 8 B T U O u t p u t V s . T e m p e r a t u r e R i s e C h a r t Reviewed by SAFEbuilt 07/27/2021 16www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 17 Wiring Diagram — GMEC96******AA Wi r i n g i s s u b j e c t t o c h a n g e . A l w a y s re f e r t o t h e w i r i n g d i a g r a m o n t h e un i t f o r t h e m o s t u p - t o - d a t e w i r i n g . ⚠ Wa r n i n g Hi g h V o l t a g e : D i s c o n n e c t a l l p o w e r b e f o r e s e r v i c i n g o r i n s t a l l i n g t h i s u n i t . M u l t i p l e p o w e r so u r c e s m a y b e p r e s e n t . F a i l u r e t o d o s o m a y c a u s e p r o p e r t y d a m a g e , p e r s o n a l i n j u r y , o r d e a t h . ⚡ GN GND COLOR CODES: GN GREEN RD REDGYGRAY PU PURPLE PK PINK BK BLACK BL BLUEWHWHITEBRBROWN YL YELLOWORORANGE GND BK RD RD GN GN 24VA C 115 VAC GND GRD BK YLO Y W1 W2 R G C TWINN.E.C.CLASS 2 WIRE 0140F02011-A BR PK GY OR GNBL YL S2 S1 BK HU M X-FMRL1 CIRC -H EAC-H 5 21 4 3 24 V 3 AFUSE NEUTRAL DIAGNOSTIC LED'S 5 CIRC UIT CONNECTOR 10 63 4 52 7 11 1 12 8 9 FRONT COVERPRESSURESWITCH NO C FUSE 3 A MICRO TO PS2 (2) TR (9) G HI C TH (5) 24 V THERMOSTAT CONNECTIONS VALVEGAS W2 TRANSFORMER HLI (6) Y2 Y1 HLO (11) GND (4) O MVL (7) NO W1 C R CONTROLS AUTO RESET AUXILIARY LIMIT LIMIT CONTROLSMANUALRESETROLLOUTPRESS.SWTICH HIGH FIRE C SWITCHLOWFIRE PRESS MVH (1) DEHUM GND PS1 (12) LIMIT CONTROLAUTORESETPRIMARY24VAC NO PM MVC (8) INTEGRATED CONTROL MODULE C BLWR AIRINDOOR CIRCULATOR RTO MICRO TO TO+VDC EAC HUMIDIFIER ID NEUTRAL WIRING TO UNIT L INTEGRATED CONTROL MODU LEHOTSURFACE GND BLWR NEUTRAL WARNING: GROUNDED. OVERCURRENT PROTECTION DEVICE MUST BE PROPERLY SWITCH NEUTRAL ELECTRONIC AIR IGN IND HI DISCONNECT FS POLARIZED AND NEUTRAL LINE NEUTRAL JUNCTION BOX BLWR IND LO N INDOOR AIR CLEANER HUM DOOR NEUTRAL INTEGRATED CONTROL MODU LE TO 115VAC/ 1 Ø /60 HZ POW ER SUPPLY W ITH 115 VAC HUM-OUT IGNITER CIRCULATOR BEFORE SERVICING. FLAME SENSOR DISCONNECT POW ER LINE GND T4 T1 T2 OR BR BK WH WH WH WH PU GY YL OR BR PK RD WH BK PU GY BR OR RD BK OR BL RD WHWH T3 COM LINE NO LIMIT CONTROLAUXILIARY AUTO RESET PK W ARNING:DISCONNECT TRANSFORMER 40 VA PU GY N NO 3 1 SW ITCHPRESSURE LOW FIRE SENSOR FLAME PRESSURE SWITCHFRONTCOVER C TO UNIT MUST BE BL RD AND GROUNDED. 1 JUN C TION BOX WH SWITCH (PRESS.) FIELD SPLICE FIELD GND 3 GN BL BR WH NO LIMIT CONTROL AUTO RESET PRIMARY W H 1 OR 30 kBTU AND 40 kBTU) CONTROLS (SINGLE CONTROL ONMANUALRESETROLLOUTLIMIT WH L PU GY BK SWITCH ASSEMBLY ID BLOWER TWO-STAGE PRESSURE OR W H SERVICING. W IRING EQUIPMENT GND INTERNAL TO SW ITCH PRESSUREHIGHFIRE PROT. DEVICE INTEGRATED CONTROL PK PU PLUG CONNECTION 2 4 BK C DOOR OPEN)(OPEN WHENDOORSWITCHCOMPARTMENT BLOWER SWITCH (TEMP.) GND 1 BLOWERCIRCULATOR JUNCTION OR 40 VA Ø /60 HZ DISCONNECT (WHITE RODGERS) GAS VALVE TWO STAGE OVERCURRENT CONNECTOR 2 CIRCUIT LOW VOLTAGE (24V) YL GND WH CH AS SIS GROUND2 3 IGNITER SURFACE HOT 2 YL PU C2 C BLOW ER DRAFTINDUCED BK PM BK BLOWER COMPARTMENT 115 VAC/1 OVERCURRENT BK HARNESS ECM MTR HI TERMINAL OR POW ER BEFORE IGNITER RD BK TO RD POWER SUPPLY WITH BURNER COMPARTMENT PROTECTION DEVICE PROPERLY POLARIZED RD BK ORBL LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD RAPID =TWINNING ERROR STEADY ON =INTERNAL GV ERROR,MICRO AND FREQUENCY CHECK 1 FLASH =FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT 4 FLASHES =OPEN LIMIT SWITCH RED LED FLASH CODE 2 FLASHES =PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR 3 FLASHES =1ST STAGE PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR 5 FLASHES =OPEN ROLLOUT/OPEN FUSE DETECTED 6 FLASHES =PRESSURE SWITCH CYCLE LOCKOUT 7 FLASHES =EXTERNAL LOCKOUT (RETRIES) 8 FLASHES =EXTERNAL LOCKOUT (RECYCLES) 9 FLASHES +GROUNDING OR REVERSED POLARITY 10 FLASHES =GAS FLOW WITH NO CALL FOR HEAT 11 FLASHES =LIMIT SWITCH OPEN-BLOWER FAILURE 12 FLASHES =IGNITOR RELAY FAILURE 3 DOUBLE FLASHES =2ND STAGE PRESSURE SWITCH STUCK OPEN/INDUCER ERROR 3 FLASHES =W2 PRESENT WITH NO W1 2 FLASHES =NORMAL OPERATION WITH CALL FOR 2ND STAGE HEAT 1 FLASH =NORMAL OPERATION WITH CALL FOR 1ST STAGE HEAT (W1) 4 FLASHES =Y PRESENT WITH NO G CALL,YLO PRESENT WITH NO G CALL AMBER LED FLASH CODE RAPID =LOW FLAME SENSE CURRENT RAPID =NORMAL OPERATION WITH CALL FOR FAN (G) STEADY ON =STANDBY 1 FLASH =NORMAL OPERATION WITH CALL FOR LOW STAGE COOL (YLO +G) GREEN LED FLASH CODE 2 FLASHES =NORMAL OPERATION WITH CALL FOR HIGH STAGE COOL/OR SINGLE STAGE COOLING (Y +G) 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. NOTES: 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USEDWHENSERVICING. MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIALHAVINGATEMPERATURERATINGOFATLEAST105C.USE COPPERCONDUCTORSONLY.4.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.5.TO RECALL THE LAST 6 FAULTS,MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE N.E.C. CLASS 2 WIRE Reviewed by SAFEbuilt 07/27/2021 18 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com 19 Wiring Diagram —GMEC96******AB GN GND COLOR CODES: GN GREEN RD RED GY GRAY PU PURPLE PK PINK BK BLACK BL BLUE WH WHITE BR BROW N YL YELLOW OR ORANGE GND BK RD RD GN GN 24VA C 11 5 VA C GND GR D BK YLO Y W 1 W2 R G C TWIN N.E.C.CLASS 2 WIRE 0140F02058-A BR PK GY OR GNBL YL S1 BK HU M X-FMRL1 CIRC -H EA C-H 5 21 4 3 24 V 3 A FUSE NEUTRAL DIAGNOSTIC LED'S 5 CIRC U IT CONN ECTOR 10 63 4 52 7 11 1 12 8 9 FRONT COVER PRESSURE SWITCH NO C FUSE 3 A MICR O TO PS2 (2) TR (9) G HI C TH (5) 24 V THERMOSTAT CONNECTIONS N.E.C. CLAS S 2 WIRE VALVEGAS W 2 TRANSFORMER HLI (6) Y2 Y1 HLO (11 ) GND (4) O MVL (7) NO W1 C R CONTROLS AUTO RESET AUXILIARY LIMIT LIMIT CONTROLS MANUAL RESET ROLLOUTPRESS.SWTICH HIGH FIRE C SWITCH LOW FIRE PRESS MVH (1) DEHUM GND PS1 (12) LIMIT CONTROL AUTO RESET PRIMARY24VAC NO PM MVC (8) INTEGRATED CONTROL MODULE C BLWR AIRINDOOR CIRCULATOR R TO MICRO TO TO +VDC EAC HUMIDIFIER ID NEUTRAL W IRING TO UNIT L INTEGRATED CONTROL MODULEHOTSURFACE GND BLWR NEUTRAL WARNING: GROUNDED. OVERCURRENT PROTECTION DEVICE MUST BE PROPERLY SWITCH NEUTRAL ELECTRONIC AIR IGN IND HI DISCONNECT FS POLARIZED AND NEUTRAL LINE NEUTRAL JUNCTION BOX BLWR IND LO N INDOOR AIR CLEANER HUM DOOR NEUTRAL INTEGRATED CONTROL MODU LE TO 115VAC/1 Ø /60 HZ POWER SUPPLY WITH 115 VAC HUM-OUT IGNITER CIRCULATOR BEFORE SERVICING. FLAME SENSOR DISCONNECT POWER LINE GND T4 T1 T2 OR BR BK WH WH WH WH PU GY YL OR BR PK RD WH BK PU GY BR OR RD BK OR BL RD WHWH T3 COM LINE NO LIMIT CONTROL AUXILIARY AUTO RESET PK W ARNING:DISCONNECT TRANSFORMER 40VA PU GY N NO 3 1 SWITCH PRESSURE LOW FIRE SENSOR FLAME PRESSURE SWITCH FRONT COVER C TO UNIT MUST BE BL RD AND GROUNDED. 1 JUNC TION BOX WH SWITCH (PRESS.) FIELD SPLICE FI ELD GND 3 GN BL BR WH NO LIMIT CONTROL AUTO RESET PRIMARY W H 1 OR 30 kBTU AND 40 kBTU) CONTROLS (SINGLE CONTROL ON MANUAL RESET ROLLOUT LIMIT WH L PU GY BK SWITCH ASSEMBLY ID BLOWER TWO-STAGE PRESSURE OR W H SERVICING.W IRING EQUIPMENT GND INT ERNAL TO SWITCH PRESSURE HIGH FIRE PROT.DEVICE INTEGRATED CONTROL PK PU PLUG CONNECTION 2 4 BK C DOOR OPEN) (OPEN WHEN DOOR SWITCH COMPARTMENT BLOWER SW ITCH (TEMP.) GND 1 BLOWERCIRCULATOR JUNCTION OR 40 VA Ø /60 HZ DISCONNECT (WHITE RODGERS) GAS VALVE TWO STAGE OVERCURRENT CONNECTOR 2 CIRCUIT LOW VO LTAGE (24V) YL GND W H CH ASS IS GROUND2 3 IGNITER SURFACE HOT 2 YL PU C2 C BLOWER DRAFT INDUCED BK PM BK BLOWER COMPARTMENT 115 VAC/1 OVERCURRENT BK HARNESS ECM MTR HI TERMINAL OR POW ER BEFORE IGNITER RD BK TO RD POWER SUPPLY WITH BURNER COMPARTMENT PROTECTION DEVICE PROPERLY POLARIZED RD BK OR BL LOW VO LTAGE FIELD HI VOL TAGE (115V) HI VOL TAGE FIELD RAPID =TWINNING ERROR STEADY ON =INTERNAL GV ERROR,MICRO AND FREQUENCY CHECK 1 FLASH =FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT 4 FLASHES =OPEN LIMIT SW ITCH 0 4 3 2 1 RED LED FLASH CODE 2 FLASHES =PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR 3 FLASHES =1ST STAGE PRESSURE SWITCH STUCK OPEN/INDUCER ERROR 5 FLASHES =OPEN ROLLOUT/OPEN FUSE DETECTED 6 FLASHES =PRESSURE SWITCH CYCLE LOCKOUT 7 FLASHES =EXTERNAL LOCKOUT (RETRIES) 9 6 5 7 8 8 FLASHES =EXTERNAL LOCKOUT (RECYCLES) 9 FLASHES +GROUNDING OR REVERSED POLARITY 10 FLASHES =GAS FLOW WITH NO CALL FOR HEAT 11 FLASHES =LIMIT SWITCH OPEN-BLOWER FAILURE 12 FLASHES =IGNITOR RELAY FAILURE 1 1 10 12 3 DOUBLE FLASHES =2ND STAGE PRESSURE SWITCH STUCK OPEN/INDUCER ERROR 3 FLASHES =W 2 PRESENT WITH NO W1 2 FLASHES =NORMAL OPERATION W ITH CALL FOR 2ND STAGE HEAT 1 FLASH =NORMAL OPERATION WITH CALL FOR 1ST STAGE HEAT (W1) 2 4 3 1 4 FLASHES =Y PRESENT WITH NO G CALL,YLO PRESENT WITH NO G CALL AMBER LED FLASH CODE RAPID =LOW FLAME SENSE CURRENT RAPID =NORMAL OPERATION WITH CALL FOR FAN (G) STEADY ON =STANDBY 1 FLASH =NORMAL OPERATION WITH CALL FOR LOW STAGE COOL (YLO +G) 0 2 1 GREEN LED FLASH CODE 2 FLASHES =NORMAL OPERATION WITH CALL FOR HIGH STAGE COOL/OR SINGLE STAGE COOLING (Y +G) 0 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. NOTES: $ 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C.USE COPPER CONDUCTORS ONLY.4.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.5.TO RECALL THE LAST 6 FAULTS,MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 3.IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE S2 S3 Wi r i n g i s s u b j e c t t o c h a n g e . A l w a y s re f e r t o t h e w i r i n g d i a g r a m o n t h e un i t f o r t h e m o s t u p - t o - d a t e w i r i n g . ⚠ Wa r n i n g Hi g h V o l t a g e : D i s c o n n e c t a l l p o w e r b e f o r e s e r v i c i n g o r i n s t a l l i n g t h i s u n i t . M u l t i p l e p o w e r so u r c e s m a y b e p r e s e n t . F a i l u r e t o d o s o m a y c a u s e p r o p e r t y d a m a g e , p e r s o n a l i n j u r y , o r d e a t h . ⚡ Reviewed by SAFEbuilt 07/27/2021 18www.goodmanmfg.comSS-GMEC96 SS-GMEC96 www.goodmanmfg.com 19 Wiring Diagram — GMEC96******AC Wi r i n g i s s u b j e c t t o c h a n g e . A l w a y s re f e r t o t h e w i r i n g d i a g r a m o n t h e un i t f o r t h e m o s t u p - t o - d a t e w i r i n g . ⚠ Wa r n i n g Hi g h V o l t a g e : D i s c o n n e c t a l l p o w e r b e f o r e s e r v i c i n g o r i n s t a l l i n g t h i s u n i t . M u l t i p l e p o w e r so u r c e s m a y b e p r e s e n t . F a i l u r e t o d o s o m a y c a u s e p r o p e r t y d a m a g e , p e r s o n a l i n j u r y , o r d e a t h . ⚡ GN GND COLOR CODES: GN GREEN RD RED GY GRAY PU PURPLE PK PINK BK BLACK BL BLUE WH WHITE BR BROWN YL YELLOW OR ORANGE GND BK RD GN GN 24VA C 11 5 VA C GND GR D BK YLO Y W1 W2 R G C TWIN N.E.C.CLASS 2 WIRE 0140F02347-A BR PK GY OR GNBL YL S1 BK HU M X- F M R L1 CI R C - H EA C - H 5 21 43 24 V 3 A FUSE NEUTRAL DIAGNOSTIC LED'S 5 C I R C U I T C O N N E C T O R 10 63 4 52 7 11 1 12 8 9 FRONT COVER PRESSURE SWITCH NO C FUSE 3 A MICRO TO PS2 (2) TR (9) G HI C TH (5) 24 V T H E R M O S T A T C O N N E C T I O N S N . E . C . C L A S S 2 W I R E VALVEGAS W2 TRANSFORMER HLI (6) Y2 Y1 HLO (11) GND (4) O MVL (7) NO W1 C R CONTROLS AUTO RESET AUXILIARY LIMIT LIMIT CONTROLS MANUAL RESET ROLLOUTPRESS.SWTICH HIGH FIRE C SWITCH LOW FIRE PRESS MVH (1) DEHUM GND PS1 (12) LIMIT CONTROL AUTO RESET PRIMARY24VAC NO PM MVC (8) INTEGRATED CONTROL MODULE C BLWR AIRINDOOR CIRCULATOR R TO MICRO TO TO +VDC EAC HUMIDIFIER ID NEUTRAL WIRING TO UNIT L IN T E G R A T E D C O N T R O L M O D U L E HOT SURFACE GND BLWR NEUTRAL W ARNING: GROUNDED. OVERCURRENT PROTECTION DEVICE MUST BE PROPERLY SWITCH NEUTRAL ELECTRONIC AIR IGN IND HI DISCONNECT FS POLARIZED AND NEUTRAL LINE NEUTRAL JUNCTION BOX BLWR IND LO N INDOOR AIR CLEANER HUM DOOR NEUTRAL IN T E G R A T E D C O N T R O L M O D U L E TO 115VAC/1 Ø /60 HZ POWER SUPPLY WITH 115 VAC HUM-OUT IGNITER CIRCULATOR BEFORE SERVICING. FLAME SENSOR DISCONNECT POWER LINE GND T1 T2 OR BR BK WH WH WH WH PU GY YL OR BR PK RD WH BK PU GY BR OR RD OR BL RD WHWH LINE NO LIMIT CONTROL AUXILIARY AUTO RESET PK WARNING:DISCONNECT TR A N S F O R M E R 40 V A PU GY N NO 3 1 SWITCH PRESSURE LOW FIRE SENSOR FLAME PRESSURE SWITCH FRONT COVER C TO UNIT MUST BE BL RD AND GROUNDED. 1 JU N C T I O N B O X WH SWITCH (PRESS.) FIELD SPLICE FIELD GND 3 GN BL BR WH NO LIMIT CONTROL AUTO RESET PRIMARY WH 1 OR 30 kBTU AND 40 kBTU) CONTROLS (SINGLE CONTROL ON MANUAL RESET ROLLOUT LIMIT WH L PU GY BK SWITCH ASSEMBLY ID BLOWER TWO-STAGE PRESSURE OR WH SERVICING. WIRING EQUIPMENT GND INTERNAL TO SWITCH PRESSURE HIGH FIRE PROT. DEVICE INTEGRATED CONTROL PK PU PLUG CONNECTION 2 4 BK C DOOR OPEN) (OPEN WHEN DOOR SWITCH COMPARTMENT BLOWER SWITCH (TEMP.) GND 1 BLOWERCIRCULATOR JUNCTION OR 40 VA Ø /60 HZ DISCONNECT (WHITE RODGERS) GAS VALVE TWO STAGE OVERCURRENT CONNECTOR 2 CIRCUIT LOW VOLTAGE (24V) YL GND WH CH A S S I S G R O U N D 2 3 IGNITER SURFACE HOT 2 YL PU C2 C BLOWER DRAFT INDUCED BK PM BK BLOWER COMPARTMENT 115 VAC/1 OVERCURRENT BK HARNESS ECM MTR HI TERMINAL OR POWER BEFORE IGNITER RD BK TO RD POWER SUPPLY WITH BURNER COMPARTMENT PROTECTION DEVICE PROPERLY POLARIZED RD BK OR BL LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD RAPID =TWINNING ERROR STEADY ON =INTERNAL GV ERROR, MICRO AND FREQUENCY CHECK 1 FLASH =FLAME SENSED WHEN NO FLAME SHOULD BE PRESENT 4 FLASHES =OPEN LIMIT SWITCH 0 4 3 2 1 RED LED FLASH CODE 2 FLASHES =PRESSURE SWITCH STUCK CLOSED/INDUCER ERROR 3 FLASHES =1ST STAGE PRESSURE SWITCH STUCK OPEN/INDUCER ERROR 5 FLASHES =OPEN ROLLOUT/OPEN FUSE DETECTED 6 FLASHES =PRESSURE SWITCH CYCLE LOCKOUT 7 FLASHES =EXTERNAL LOCKOUT (RETRIES) 9 6 5 7 8 8 FLASHES =EXTERNAL LOCKOUT (RECYCLES) 9 FLASHES +GROUNDING OR REVERSED POLARITY 10 FLASHES =GAS FLOW WITH NO CALL FOR HEAT 11 FLASHES =LIMIT SWITCH OPEN-BLOWER FAILURE 12 FLASHES =IGNITOR RELAY FAILURE 11 10 12 3 DOUBLE FLASHES =2ND STAGE PRESSURE SWITCH STUCK OPEN/INDUCER ERROR 3 FLASHES =W2 PRESENT WITH NO W1 2 FLASHES =NORMAL OPERATION WITH CALL FOR 2ND STAGE HEAT 1 FLASH =NORMAL OPERATION WITH CALL FOR 1ST STAGE HEAT (W1) 2 4 3 1 4 FLASHES =Y PRESENT WITH NO G CALL,YLO PRESENT WITH NO G CALL AMBER LED FLASH CODE RAPID =LOW FLAME SENSE CURRENT RAPID = NORMAL OPERATION WITH CALL FOR FAN (G) STEADY ON =STANDBY 1 FLASH =NORMAL OPERATION WITH CALL FOR LOW STAGE COOL (YLO +G) 0 2 1 GREEN LED FLASH CODE 2 FLASHES =NORMAL OPERATION WITH CALL FOR HIGH STAGE COOL/OR SINGLE STAGE COOLING (Y +G) 0 1.SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. NOTES: $ 2.MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C.USE COPPER CONDUCTORS ONLY.4.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 5.TO RECALL THE LAST 6 FAULTS,MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 3.IF ANY OF THE ORIGINAL W IRE AS SUPPLIED W ITH THE FURNACE S3 S2 T5T3T4 RD CO M BK Reviewed by SAFEbuilt 07/27/2021 20 www.goodmanmfg.com SS-GMEC96 SS-GMEC96 www.goodmanmfg.com PB Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2017 Goodman Manufacturing Company, L.P. • Houston, Texas Accessories Model Description GMEC96 0303ANA GMEC96 0403ANA GMEC96 0603ANA GMEC96 0302BNA GMEC96 0402BNA GMEC96 0603BNA GMEC96 0803BNA CVENT-2 Concentric Vent Kit (2") √√√√√√√ CVENT-3 Concentric Vent Kit (3") √√√√√√√ RF000142 Drain Kit -Horizontal Left Vertical Flue √√√√√√√ EFR02 External Filter Rack with 16"x25" Permanent Filter √√√√√√√ 0170K00000S Flush Mount Vent Kit - 3" or 2" √√√√√√√ 0170K00001S Flush Mount Vent Kit - 2"√√√√√√√ AFE18-60A Fossil Fuel (Dual Fuel) Kit √√√√√√√ HASFK High-Altitude Natural Gas Kit N/A TBD TBD N/A HASFK-1 HASFK-1 HASFK-2 HASFK High-Altitude LP Gas Kit N/A TBD TBD N/A HASFK-1 HASFK-1 HASFK-2 LPLP03 Low LP Gas Pressure Switch √√√√√√√ LPM-08 LP Conversion Kits ---√√---√√√ LPM-30 LP Conversion Kit √------√--------- Model Description GMEC96 0804CNA GMEC96 1004CNA GMEC96 1005CNA GMEC96 1205DNA CVENT-2 Concentric Vent Kit (2") √√√ CVENT-3 Concentric Vent Kit (3") √√√√ RF000142 Drain Kit -Horizontal Left Vertical Flue √√√√ EFR02 External Filter Rack with 16"x25" Permanent Filter √√√--- 0170K00000S Flush Mount Vent Kit - 3" or 2" √√√√ 0170K00001S Flush Mount Vent Kit - 2"√√√√ AFE18-60A Fossil Fuel (Dual Fuel) Kit √√√√ HASFK High-Altitude Natural Gas Kit HASFK-2 HASFK-2 HASFK-3 HASFK-3 HASFK High-Altitude LP Gas Kit HASFK-2 HASFK-2 HASFK-2 HASFK-2 LPLP03 Low LP Gas Pressure Switch √√√√ LPM-08 LP Conversion Kits √√√√ LPM-30 LP Conversion Kit ------------ Reviewed by SAFEbuilt 07/27/2021