Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS Single Family Residence 200 Cherokee Ct 2021-06-28
APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 06/28/2021 This structure must comply with the requirements of the 2020 National Electrical Code PRINT PLANS IN COLOR AND HAVE FOR INSPECTOR AT TIME OF INSPECTION Rim joist shall have an air barrier on the interior between each joist. All architectural plans, engineered foundation plans, soils reports, truss drawings, energy code report or ResCheck must be onsite for inspections. Ice barrier required from the lowest edges of all roof surfaces to a point not less than 24" inside the exterior wall line of the building. IRC R905.1.2 All Irrigation Sprinkler Taps Shall be Protected by an Approved Back Flow Device Reviewed by SAFEbuilt 06/28/2021 MAX RAILING SPACE IS 4" Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 PROVIDE A CONTINUOUS RAIL PROVIDE REQUIRED FIXTURE SPACING PER R307.1 PROVIDE REQUIRED FIXTURE SPACING PER R307.1 PROVIDE REQUIRED FIXTURE SPACING PER R307.1 MAX DRYER EXHAUST VENT DUCT LENGTH IS 35' OR PER MANUFACTURER'S INSTALLATION INSTRUCTIONS SD SD COD SD SD SD COD Reviewed by SAFEbuilt 06/28/2021 PROVIDE A CONTINUOUS RAIL SEE APPROVED ENGINEERED STRUCTURAL PLANS PROVIDE REQURIED COMBUSTION AIR CRAWLSPACE MUST BE VENTILATED PER R408 2015 IECC sec. R402.4.4 Appliances must be direct vent (combustion and exhaust) or the mechanical equipment must be located within a room entirely isolated from the rest of the building's thermal envelope in accordance with sec. R402.4.4 Reviewed by SAFEbuilt 06/28/2021 SEE APPROVED ENGINEERED STRUCTURAL PLANS Reviewed by SAFEbuilt 06/28/2021 SEE APPROVED ENGINEERED STRUCTURAL PLANS Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 Reviewed by SAFEbuilt 06/28/2021 Job #: Performed for: Kinley Built Cherokee Ct Estes Park, Co Rockview Designs Fort Collins Scale: 1 : 100 Page 1 Rig ht-Su ite® Univ ersa l 202 1 21.0.07 RSU29846 2021-Jun-20 18:26:39 ... Built\Smith\Smith Residence.rup N Crawlspace Crawlspace Mech Ret Riser 25 x 12 8 "20 x 10 20 x 8 8 " 6 " 16 x 8 7 "8 " 8 " 8 " 5 " 16 x 8 5 " 6 " 4 " 6 " 4 " 6 " 6 " 6 " 6 " 6 " 6 " 6 " 10 x 8 12 x 8 10 x 4 155 cfm Reviewed by SAFEbuilt 06/28/2021 Job #: Performed for: Kinley Built Cherokee Ct Estes Park, Co Rockview Designs Fort Collins Scale: 1 : 100 Page 2 Rig ht-Su ite® Univ ersa l 202 1 21.0.07 RSU29846 2021-Jun-20 18:26:39 ... Built\Smith\Smith Residence.rup N Main Floor Master Bedroom Entry Great Room Dining Den Pantry Bedroom 3 Bedroom 2 Sink Area Bath 2 Laundry Master Bath Master Closet Hall/Stairs Kitchen/Nook 10 x 4 84 cfm 10 x 2 17 cfm 10 x 4 61 cfm 10 x 4 99 cfm 10 x 4 99 cfm 10 x 4 95 cfm 10 x 4 95 cfm 6 " 95 cfm 10 x 4 90 cfm 10 x 4 87 cfm 10 x 4 84 cfm 10 x 4 41 cfm 14 x 6 183 cfm 14 x 6 131 cfm 14 x 6 95 cfm 15 x 6 164 cfm 15 x 6 110 cfm 10 x 4 50 cfm 10 x 4 50 cfm 15 x 6 197 cfm 15 x 6 192 cfm Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Project Summary Jun 19, 2021Date:Entire House By: Rockview Designs Fort Collins Project Information Kinley BuiltFor:Cherokee Ct, Estes Park, Co Notes: Design Information Fort Collins SAWRS, CO, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F4 Outside db °F91Inside db °F72 Inside db °F75 Design TD °F68 Design TD °F16Daily range M Relative humidity %50Moisture difference gr/lb-24 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh29971 Structure Btuh21037 Ducts Btuh0 Ducts Btuh0Central vent (71 cfm)4412 Btuh Central vent (71 cfm)Btuh1038 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh34383 Use manufacturer's data y Rate/swing multiplier 1.00InfiltrationEquipment sensible load Btuh22075 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight0Fireplaces Structure Btuh220 Ducts Btuh0Central vent (71 cfm)Btuh-971 CoolingHeating Outside air40904090Area (ft²)Equipment latent load Btuh0 2540125401Volume (ft³)Air changes/hour 0.100.19 Equipment Total Load (Sen+Lat)Btuh22075 Equiv. AVF (cfm)4280 Req. total capacity at 1.00 SHR ton1.8 Heating Equipment Summary Cooling Equipment Summary Make Carrier Make CarrierTradeCarrier Comfort 95 Single-Stag...Trade 13 SEER AC Model 59SC5B060E17--14 Cond CA13NA030BNG0DAHRI ref 0 Coil CNPVP3617ALA AHRI ref 0Efficiency96.5 AFUE Efficiency 12.0 EER, 14 SEER Heating input Btuh60000 Sensible cooling Btuh24000Heating output Btuh45150 Latent cooling Btuh0 Temperature rise °F53 Total cooling Btuh24000Actual air flow cfm925 Actual air flow cfm1050 Air flow factor cfm/Btuh0.031 Air flow factor cfm/Btuh0.050Static pressure in H2O0.70 Static pressure in H2O0.80 Space thermostat Load sensible heat ratio 1.00 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Entire House By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B-15sfc-4: Bg wall, light dry soil, concrete wall, r-15 ins, 8" thk 2552.3215.00.041110ne 00 004352.7915.00.041156se 005382.7915.00.041193sw 005332.7915.00.041191nw 0017612.7115.00.041650all R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 3910.9214433.4020.00.050425ne 3720.9213753.4020.00.050405se 4270.9215783.4020.00.050464sw 4680.9217303.4020.00.050509nw 16580.9261263.4020.00.0501802all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 402724.9352521.800.320162ne 381830.5272021.800.320125se 232130.5165421.800.32076sw 49724.943521.800.32020nw 1066427.8833421.800.320383all Doors 11D0: Door, wd sc type 45010.7111426.500.39042ne 45010.7111426.500.39042ne 90110.7222826.500.39084all Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 25661.0234211.3649.00.0202515 Floors 21A-32t: Bg floor, heavy dry or light damp soil, 4' depth 00.0201574 0021411.36 R30 over ambient: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-30 cav ins, amb ovr 3090.369551.1230.00.033851 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 2 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 3 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Master Bedroom By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 880.923243.4020.00.05095ne 310.921153.4020.00.05034se 1280.924743.4020.00.050140nw 2470.929133.4020.00.050269all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 104424.991421.800.32042ne Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 2411.023211.3649.00.020236 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 4 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Entry By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 610.922243.4020.00.05066ne Partitions (none) Windows (none) Doors 11D0: Door, wd sc type 45010.7111426.500.39042ne Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 1801.022401.3649.00.020176 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 5 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Great Room By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1490.925513.4020.00.050162ne 940.923473.4020.00.050102se 910.923373.4020.00.05099nw 3340.9212343.4020.00.050363all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 208824.9182821.800.32084ne Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 4341.025791.3649.00.020426 Floors R30 over ambient: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-30 cav ins, amb ovr 1550.364781.1230.00.033426 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 6 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Dining By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 1471.021961.3649.00.020144 Floors R30 over ambient: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-30 cav ins, amb ovr 160.36511.1230.00.03345 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 7 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Den By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 650.922403.4020.00.05071se 950.923523.4020.00.050104sw 1600.925923.4020.00.050174all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 128330.591421.800.32042se Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 1471.021961.3649.00.020144 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 8 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Pantry By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 190.92693.4020.00.05020sw Partitions (none) Windows (none) Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 411.02551.3649.00.02040 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 9 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Bedroom 3 By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 540.921993.4020.00.05059se 970.923593.4020.00.050106sw 1510.925583.4020.00.050164all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 76430.554421.800.32025sw Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 1961.022611.3649.00.020192 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 10 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Bedroom 2 By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 910.923363.4020.00.05099sw 970.923603.4020.00.050106nw 1880.926953.4020.00.050205all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 76430.554421.800.32025sw Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 1901.022531.3649.00.020186 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 11 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Sink Area By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 381.02511.3649.00.02038 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 12 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Bath 2 By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 460.921713.4020.00.05050sw Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 18330.513121.800.3206sw Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 431.02571.3649.00.02042 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 13 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Laundry By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 631.02841.3649.00.02062 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 14 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Master Bath By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 250.92923.4020.00.05027ne 830.923073.4020.00.05090nw 1080.923993.4020.00.050117all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 49724.943521.800.32020nw Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 1331.021771.3649.00.020130 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 15 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Master Closet By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 680.922523.4020.00.05074nw Partitions (none) Windows (none) Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 691.02921.3649.00.02068 Floors (none) Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 16 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Hall/Stairs By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 2681.023571.3649.00.020262 Floors R30 over ambient: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-30 cav ins, amb ovr 40.36121.1230.00.03311 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 17 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Kitchen/Nook By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls R20 Frame Wall: Frm wall, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 680.922523.4020.00.05074ne 1290.924753.4020.00.050140se 790.922923.4020.00.05086sw 2760.9210193.4020.00.050300all Partitions (none) Windows Window 32: 2 glazing, heat abs outr, argon gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" thk; 6.67 ft head ht 89524.978321.800.32036ne 253530.5180621.800.32083se 61130.543521.800.32020sw 404129.1302521.800.320139all Doors (none) Ceilings R-49 Attic Blown: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 1/2" gypsum board int fnsh 3771.025021.3649.00.020369 Floors R30 over ambient: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-30 cav ins, amb ovr 1340.364141.1230.00.033369 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 18 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Component Constructions Jun 19, 2021Date:Crawlspace By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 15B-15sfc-4: Bg wall, light dry soil, concrete wall, r-15 ins, 8" thk 2552.3215.00.041110ne 00 004352.7915.00.041156se 005382.7915.00.041193sw 005332.7915.00.041191nw 0017612.7115.00.041650all Partitions (none) Windows (none) Doors 11D0: Door, wd sc type 45010.7111426.500.39042ne Ceilings (none) Floors 21A-32t: Bg floor, heavy dry or light damp soil, 4' depth 00.0201574 0021411.36 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:06 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Building Analysis Jun 19, 2021Date:Entire House By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) SimplifiedMethod)M(20-Da ily ra nge (°F) Semi-tightConstruction quality62-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 22.978873.2Walls 24.2833421.8Glazing 6.5222826.5Doors 9.934211.4Ceilings 9.030961.31.3Floors 14.650062.2Infiltration 00Ducts 00Piping 00Humidification 12.84412Ventilation0Adjustments 100.034383Total Cooling Walls Glazing Doors Ceilings Other Infiltration Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 7.516580.7Walls 48.31066427.8Glazing 4.190110.7Doors 11.625661.0Ceilings 1.43090.1Floors 2.86200.3Infiltration 00Ducts 4.71038Ventilation 19.64320Internal gains 00Blower 0Adjustments 100.022075Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 49 Btuh/ft²-°F Data entries checked. Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Entire House Master Bedroom 2 Exposed wall 405.0 ft 34.5 ft 3 Room height 7.8 ft 9.0 heat/coolft 4 Room dimensions ft15.5x15.3 5 Room area 4089.7 f t²236.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 152 110 255 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 42 42 1114 450 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 629 425 1443 391 137 95 324 88 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 162 0 3525 4027 42 0 914 1044 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 42 42 1114 450 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 156 156 435 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 530 405 1375 372 34 34 115 31 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 125 0 2720 3818 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 193 193 538 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 540 464 1578 427 0 0 0 0 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 76 0 1654 2321 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 191 191 533 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 529 509 1730 468 140 140 474 128 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 20 0 435 497 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 2515 2515 3421 2566 236 236 321 241 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 1574 1574 2141 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 851 851 955 309 0 0 0 0 6 c) AED excursion 0 -74 Envelope loss/gain 24966 16097 2148 1458 12 a)Infiltration 5006 620 698 86 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 2 460 Appliances/other 3400 0 Subtotal (lines 6 to 13)29971 21037 2846 2005 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 29971 21037 2846 2005 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 29971 21037 2846 2005 Air required (cfm)Air required (cfm)925 1050 88 100 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 2...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Entry Great Room 2 Exposed wall 9.0 ft 37.3 ft 3 Room height 12.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft176.2x1.0 ft425.9x1.0 5 Room area 176.2 f t²425.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 108 66 224 61 246 162 551 149 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 0 0 0 0 84 0 1828 2088 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 42 42 1114 450 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 0 0 0 0 102 102 347 94 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 0 0 0 0 99 99 337 91 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 176 176 240 180 426 426 579 434 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 0 0 0 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 0 0 0 0 426 426 478 155 6 c) AED excursion -38 -141 Envelope loss/gain 1578 653 4119 2870 12 a)Infiltration 243 30 1005 124 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13)1821 683 5124 3894 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 141 279 132 85 14 Subtotal 1962 962 5256 3980 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1962 962 5256 3980 Air required (cfm)Air required (cfm)61 48 162 199 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 3...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Dining Den 2 Exposed wall 0 ft 24.0 ft 3 Room height 12.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.5x12.5 ft12.5x11.5 5 Room area 143.8 f t²143.8 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 0 0 0 0 0 0 0 0 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 0 0 0 0 113 71 240 65 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 0 0 0 0 42 0 914 1283 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 0 0 0 0 104 104 352 95 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 144 144 196 147 144 144 196 147 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 0 0 0 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 45 45 51 16 0 0 0 0 6 c) AED excursion -9 76 Envelope loss/gain 246 154 1701 1666 12 a)Infiltration 0 0 486 60 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)246 154 2187 1726 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -246 -154 162 86 14 Subtotal 0 0 2349 1812 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 2349 1812 Air required (cfm)Air required (cfm)0 0 72 90 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 4...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Pantry Bedroom 3 2 Exposed wall 2.3 ft 21.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft40.3x1.0 ft192.1x1.0 5 Room area 40.3 f t²192.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 0 0 0 0 0 0 0 0 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 0 0 0 0 59 59 199 54 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 20 20 69 19 131 106 359 97 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 0 0 0 0 25 0 544 764 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 40 40 55 41 192 192 261 196 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 0 0 0 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 0 0 0 0 0 0 0 0 6 c) AED excursion -3 217 Envelope loss/gain 124 56 1363 1328 12 a)Infiltration 46 6 425 53 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)169 62 1788 1610 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -169 -62 226 125 14 Subtotal 0 0 2014 1736 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 2014 1736 Air required (cfm)Air required (cfm)0 0 62 87 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 5...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Bedroom 2 Sink Area 2 Exposed wall 25.5 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft185.9x1.0 ft6.0x6.3 5 Room area 185.9 f t²37.5 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 0 0 0 0 0 0 0 0 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 124 99 336 91 0 0 0 0 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 25 0 544 764 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 106 106 360 97 0 0 0 0 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 186 186 253 190 38 38 51 38 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 0 0 0 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 0 0 0 0 0 0 0 0 6 c) AED excursion 215 -2 Envelope loss/gain 1492 1356 51 36 12 a)Infiltration 516 64 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2008 1650 51 36 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 60 42 -51 -36 14 Subtotal 2068 1692 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2068 1692 0 0 Air required (cfm)Air required (cfm)64 84 0 0 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 6...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Bath 2 Laundry 2 Exposed wall 6.3 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.8x6.3 ft8.3x7.5 5 Room area 42.2 f t²61.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 0 0 0 0 0 0 0 0 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 56 50 171 46 0 0 0 0 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 6 0 131 183 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 42 42 57 43 62 62 84 63 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 0 0 0 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 0 0 0 0 0 0 0 0 6 c) AED excursion 28 -30 Envelope loss/gain 359 301 84 33 12 a)Infiltration 126 16 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 500 Subtotal (lines 6 to 13)485 816 84 533 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 17 12 -84 -533 14 Subtotal 503 829 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 503 829 0 0 Air required (cfm)Air required (cfm)16 41 0 0 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 7...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Master Bath Master Closet 2 Exposed wall 15.3 ft 8.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft130.4x1.0 ft67.5x1.0 5 Room area 130.4 f t²67.5 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 27 27 92 25 0 0 0 0 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 110 90 307 83 74 74 252 68 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 20 0 435 497 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 130 130 177 133 68 68 92 69 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 0 0 0 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 0 0 0 0 0 0 0 0 6 c) AED excursion 122 -8 Envelope loss/gain 1011 860 344 129 12 a)Infiltration 309 38 167 21 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)1320 1398 511 149 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 45 288 44 68 14 Subtotal 1365 1686 555 218 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1365 1686 555 218 Air required (cfm)Air required (cfm)42 84 17 11 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 8...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Hall/Stairs Kitchen/Nook 2 Exposed wall 0 ft 48.8 ft 3 Room height 11.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft262.4x1.0 ft369.2x1.0 5 Room area 262.4 f t²369.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nene 2.322.32 0.000.00 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 .WW R20 Frame WallR20 Frame Wall 0.0500.050 nene 3.403.40 0.920.92 0 0 0 0 110 74 252 68 .GG Window 32Window 32 0.3200.320 nene 21.7621.76 24.8624.86 0 0 0 0 36 0 783 895 1 1 DD 11D011D0 0.3900.390 nene 26.5226.52 10.7210.72 0 0 0 0 0 0 0 0 WW 15B-15sfc-415B-15sfc-4 0.0590.059 sese 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 sese 3.403.40 0.920.92 0 0 0 0 223 140 475 129 GG Window 32Window 32 0.3200.320 sese 21.7621.76 30.5530.55 0 0 0 0 83 0 1806 2535 WW 15B-15sfc-415B-15sfc-4 0.0590.059 swsw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 swsw 3.403.40 0.920.92 0 0 0 0 106 86 292 79 GG Window 32Window 32 0.3200.320 swsw 21.7621.76 30.5530.55 0 0 0 0 20 0 435 611 WW 15B-15sfc-415B-15sfc-4 0.0590.059 nwnw 2.792.79 0.000.00 0 0 0 0 0 0 0 0 WW R20 Frame WallR20 Frame Wall 0.0500.050 nwnw 3.403.40 0.920.92 0 0 0 0 0 0 0 0 GG Window 32Window 32 0.3200.320 nwnw 21.7621.76 24.8624.86 0 0 0 0 0 0 0 0 CC R-49 Attic BlownR-49 Attic Blown 0.0200.020 --1.361.36 1.021.02 262 262 357 268 369 369 502 377 FF 21A-32t21A-32t 0.0200.020 --1.361.36 0.000.00 0 0 0 0 0 0 0 0 FF R30 over ambientR30 over ambient 0.0330.033 --1.121.12 0.360.36 11 11 12 4 369 369 414 134 6 c) AED excursion -14 -315 Envelope loss/gain 369 257 4960 4513 12 a)Infiltration 0 0 986 122 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13)369 257 5946 5635 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -369 -257 91 57 14 Subtotal 0 0 6038 5692 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 6038 5692 Air required (cfm)Air required (cfm)0 0 186 284 Reviewed by SAFEbuilt 06/28/2021 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-20 18:26:06Right-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 9...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Right-J® W or ksheet Jun 19, 2021Date:Entire House By:Rockview Designs Fort Collins 1 Room name Crawlspace 2 Exposed wall 173.0 ft 3 Room height 4.0 heat/coolft 4 Room dimensions ft1574.3x1.0 5 Room area 1574.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area Load number (Bt uh/f t²-°F)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 15B-15sfc-4 0.059 ne 2.32 0.00 152 110 255 0 .D 11D0 0.390 ne 26.52 10.72 42 42 1114 450 .W R20 Frame Wall 0.050 ne 3.40 0.92 0 0 0 0 .G Window 32 0.320 ne 21.76 24.86 0 0 0 0 1 1 D 11D0 0.390 ne 26.52 10.72 0 0 0 0 W 15B-15sfc-4 0.059 se 2.79 0.00 156 156 435 0 W R20 Frame Wall 0.050 se 3.40 0.92 0 0 0 0 G Window 32 0.320 se 21.76 30.55 0 0 0 0 W 15B-15sfc-4 0.059 sw 2.79 0.00 193 193 538 0 W R20 Frame Wall 0.050 sw 3.40 0.92 0 0 0 0 G Window 32 0.320 sw 21.76 30.55 0 0 0 0 W 15B-15sfc-4 0.059 nw 2.79 0.00 191 191 533 0 W R20 Frame Wall 0.050 nw 3.40 0.92 0 0 0 0 G Window 32 0.320 nw 21.76 24.86 0 0 0 0 C R-49 Attic Blown 0.020 -1.36 1.02 0 0 0 0 F 21A-32t 0.020 -1.36 0.00 1574 1574 2141 0 F R30 over ambient 0.033 -1.12 0.36 0 0 0 0 6 c) AED excursion -24 Envelope loss/gain 5016 427 12 a)Infiltration 0 0 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)5016 427 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 5016 427 15 Duct loads -0%0%0 0 Total room load 5016 427 Air required (cfm)155 21 Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:07 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:AED Assessment Jun 19, 2021Date:Entire House By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Design Conditions Location:CoolingHeatingIndoor: 7572Indoor temp era ture (°F)Fort Collins SAWRS, CO, US 1668Design TD (°F)ft5003Elevation: 5030Relative humidity (%)°N41Latitude: Outdoor:-24.235.6Moisture difference (gr/lb)CoolingHeating Infiltration:914Dry bul b (°F) )M(20-Da ily ra nge (°F) 62-We t bu lb (°F) 7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gl a z i n g l o a d ( B t u h ) Hour of Day 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 8.5%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh Reviewed by SAFEbuilt 06/28/2021 2021-Jun-20 18:26:07 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Duct system multi orientation report Jun 19, 2021Date:Entire House By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Group 1: ( N) Group 2: (NE) Group 3: ( E) Group 4: (SE) Group 5: ( S) Group 6: (SW) Group 7: ( W) Group 8: (NW) Duct Name (SE)(E)(NE)(N) Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches Bath 2 410x441 c410x442 c410x437 c410x433 c Bedroom 2 610x484 c610x493 c610x470 c510x464 h Bedroom 3 610x487 c610x495 c610x472 c510x462 h Crawlspace 710x4155 h710x4155 h710x4155 h710x4155 h Den 610x490 c610x472 h710x4100 c710x4129 c Entry 010x461 h010x461 h010x461 h010x461 h Great Room 610x499 c710x4124 c710x4110 c610x496 c Great Room-A 610x499 c710x4124 c710x4110 c610x496 c Kitchen/Nook 610x495 c610x483 c610x498 c610x4111 c Kitchen/Nook-A 610x495 c610x483 c610x498 c710x4111 c Kitchen/Nook-B 6695 c6683 c6698 c66111 c Master Bath 610x484 c510x459 c610x471 c610x491 c Master Bedroom 510x450 c510x462 c510x455 c510x448 c Master Bedroom-A 510x450 c510x462 c510x455 c510x448 c Master Closet 410x217 h410x217 h410x217 h410x217 h Supply Trunks st1A 12x8381 h12x8381 h12x8381 h12x8381 h st2 10x8383 c10x8372 c12x8404 c12x8427 c st1 16x8619 c16x8632 c16x8601 c16x8597 h Return Branches rb7 815x6110 h815x6127 c815x6113 c815x6110 h rb1 815x6164 h815x6172 c815x6164 h815x6164 h rb2 814x6183 c814x6165 c814x6154 c814x6152 c rb3 714x6131 c714x6140 c614x6112 c614x6100 h rb6 614x695 h614x695 h614x6103 c714x6132 c rb5 815x6197 c815x6209 c915x6211 c815x6209 c rb4 815x6192 c815x6168 c815x6199 c915x6224 c Return Trunks rt3 16x8567 c16x8604 c16x8538 c16x8519 h rt1 20x101050 c20x101050 c20x101050 c20x101050 c rrs1 25x121050 c25x121050 c25x121050 c25x121050 c rt2 20x8390 c20x8378 c20x8410 c20x8434 c Friction Rates Heating FR 0.0540.0540.0540.054 Cooling FR 0.0720.0720.0720.072 Reviewed by SAFEbuilt 06/28/2021 2021-Jun-20 18:26:07 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 2 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Duct Name (NW)(W)(SW)(S) Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches Bath 2 410x434 c410x439 c410x439 c410x441 c Bedroom 2 510x464 h610x478 c610x475 c610x470 c Bedroom 3 510x462 h610x480 c610x477 c610x472 c Crawlspace 710x4155 h710x4155 h710x4155 h710x4155 h Den 610x484 c610x472 h610x473 c710x4116 c Entry 010x461 h010x461 h010x461 h010x461 h Great Room 710x4123 c710x4147 c710x4117 c610x481 h Great Room-A 710x4123 c710x4147 c710x4117 c610x481 h Kitchen/Nook 610x497 c610x474 c610x487 c610x4101 c Kitchen/Nook-A 610x497 c610x474 c610x487 c610x4101 c Kitchen/Nook-B 6697 c6674 c6687 c66101 c Master Bath 610x477 c610x470 c610x492 c710x4115 c Master Bedroom 510x462 c610x474 c510x459 c410x444 h Master Bedroom-A 510x462 c610x474 c510x459 c410x444 h Master Closet 410x217 h410x217 h410x217 h410x217 h Supply Trunks st1A 12x8381 h12x8381 h12x8381 h12x8381 h st2 12x8414 c10x8369 c10x8379 c10x8384 c st1 16x8597 h16x8635 c16x8623 c16x8611 c Return Branches rb7 815x6126 c815x6151 c815x6121 c815x6110 h rb1 815x6170 c815x6196 c815x6168 c815x6164 h rb2 814x6150 c814x6162 c814x6180 c914x6201 c rb3 614x6100 h714x6122 c714x6119 c614x6116 c rb6 614x695 h614x695 h614x695 h714x6120 c rb5 915x6223 c915x6224 c815x6208 c815x6185 c rb4 815x6197 c715x6151 c815x6178 c815x6206 c Return Trunks rt3 16x8544 c16x8630 c16x8589 c16x8539 c rt1 20x101050 c20x101050 c20x101050 c20x101050 c rrs1 25x121050 c25x121050 c25x121050 c25x121050 c rt2 20x8420 c20x8375 c20x8385 c20x8391 c Friction Rates Heating FR 0.0540.0540.0540.054 Cooling FR 0.0720.0720.0720.072 Reviewed by SAFEbuilt 06/28/2021 2021-Jun-20 18:26:07 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 3 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Duct Name SmalestLargest Duct SizeReg SizeReg CFMDuct SizeReg SizeReg CFM Supply Branches Bath 2 410x433 c410x442 c Bedroom 2 510x464 h610x493 c Bedroom 3 510x462 h610x495 c Crawlspace 710x4155 h710x4155 h Den 610x472 h710x4129 c Entry 010x461 h010x461 h Great Room 610x481 h710x4147 c Great Room-A 610x481 h710x4147 c Kitchen/Nook 610x474 c610x4111 c Kitchen/Nook-A 610x474 c710x4111 c Kitchen/Nook-B 6674 c66111 c Master Bath 510x459 c710x4115 c Master Bedroom 410x444 h610x474 c Master Bedroom-A 410x444 h610x474 c Master Closet 410x217 h410x217 h Supply Trunks st1A 12x8381 h12x8381 h st2 10x8369 c12x8427 c st1 16x8597 h16x8635 c Return Branches rb7 815x6110 h815x6151 c rb1 815x6164 h815x6196 c rb2 814x6150 c914x6201 c rb3 614x6100 h714x6140 c rb6 614x695 h714x6132 c rb5 815x6185 c915x6224 c rb4 715x6151 c915x6224 c Return Trunks rt3 16x8519 h16x8630 c rt1 20x101050 c20x101050 c rrs1 25x121050 c25x121050 c rt2 20x8375 c20x8434 c Friction Rates Heating FR 0.0540.054 Cooling FR 0.0720.072 Reviewed by SAFEbuilt 06/28/2021 2021-Jun-20 18:26:07 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 4 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Background Color Legend Yellow background Duct Size - duct size is smaller than the largest duct size in the row Reg Size - register size is smaller than the largest register size in the row Reg CFM - register design cfm is larger than 150 CFM Friction Rate - friction rate is outside ACCA Manual-D recommended range (0.06 - 0.18) Pink background column header Largest coolling load orientation Reviewed by SAFEbuilt 06/28/2021 2021-Jun-20 18:26:09 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Static Pressure and Friction Rate Jun 19, 2021Date:Entire House By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.800.70External static pressure Pressure losses 0.150.19Coil 00Heat exchanger 0.030.03Supply diffusers 0.030.03Return grilles 0.130.11Filter 00Humidifier 00Balancing damper 00Other device 0.460.34Available static pressure Total Effective Length ReturnSupply (ft)(ft) 731Measured length of run-out 2928Measured length of trunk 315225Equivalent length of fittings 351284Total length 635Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) OK0.072< 0.060.054Supply Ducts OK0.072< 0.060.054Return Ducts Fitting Equivalent Length Details 4AD=60, 2I5=110, 12O1=10, 8E=10, 1C=35: TotalEL=225Supply 6M=20, 6C6=115, 6CB=25, 6CA=10, 8E=10, 6CA=10, 10A=75, 6CA=10, 5A=40: TotalEL=315Return Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:09 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 1 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Job:Duct System Summary Jun 19, 2021Date:Entire House By: Rockview Designs Fort Collins Project Information Kinley BuiltFor: Cherokee Ct, Estes Park, Co CoolingHeating External static pressure in H2O0.80in H2O0.70 Pressure losses in H2O0.34in H2O0.36 Available static pressure in H2O0.46in H2O0.34 Supply / return available pressure 0.152 / 0.188 in H2O in H2O0.206 / 0.254 Lowest friction rate in/100ft0.072in/100ft0.054 Actual air flow cfm1050cfm925 Total effective length (TEL)ft635 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st1A225.036.8ShMt0x04.00.0794116829cBath 2 st1A210.053.8ShMt0x06.00.07884641692cBedroom 2 st1170.033.3ShMt0x06.00.10187621736cBedroom 3 st1A55.037.0ShMt0x07.00.165211555016hCrawlspace st1250.015.4ShMt0x06.00.07890721812cDen 00ShMt0x0004861962hEntry st2190.032.5ShMt0x06.00.09399811990cGreat Room st1180.048.0ShMt0x06.00.09099811990cGreat Room-A st2160.034.8ShMt0x06.00.10695621897cKitchen/Nook st2170.036.5ShMt0x06.00.10095621897cKitchen/Nook-A st2180.018.3ShMt0x06.00.10495621897cKitchen/Nook-B st1A180.045.3ShMt0x06.00.09184421686cMaster Bath st1A225.059.0ShMt0x05.00.05450441423cMaster Bedroom st1A200.070.0ShMt0x05.00.05650441423cMaster Bedroom-A st1A190.041.0ShMt0x04.00.0661117555hMaster Closet Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1A Peak AVF 381 342 0.054 572 10.9 12x8 ShtMetl st1 st2 Peak AVF 267 383 0.093 690 9.8 10x8 ShtMetl st1 Peak AVF 597 619 0.054 696 12.9 16x8 ShtMetl Reviewed by SAFEbuilt 06/28/2021 Bold/italic values have been manually overridden 2021-Jun-20 18:26:09 Rig ht-Su ite® U niv er sal 20 21 21 .0.07 RSU2 9846 Page 2 ...ulations\Kinley Built\Smith\Smith Residence.rup Calc = MJ8 Front Door faces: NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb7 0x 1100 103 256.5 0.073 315 8.0 x0 0 ShMt rt3 rb1 0x 1640 150 270.3 0.069 469 8.0 x0 0 ShMt rt3 rb2 0x 1450 183 350.5 0.072 523 8.0 x0 0 ShMt rt3 rb3 0x 1000 131 204.0 0.125 490 7.0 x0 0 ShMt rt3 rb6 0x 950 93 82.8 0.227 482 6.0 x0 0 ShMt rt1 rb5 0x 1650 197 293.3 0.087 565 8.0 x0 0 ShMt rt2 rb4 0x 1460 192 207.0 0.123 551 8.0 x0 0 ShMt rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt3 Peak AVF 519 567 0.054 638 12.3 16x8 ShtMetl rt1 rt1 Peak AVF 925 1050 0.054 756 15.3 20x10 ShtMetl rrs1 rrs1 Peak AVF 925 1050 0.054 504 15.3 25x12 ShtMetl rt2 Peak AVF 312 390 0.087 351 9.9 20x8 ShtMetl rt1 Reviewed by SAFEbuilt 06/28/2021