Loading...
HomeMy WebLinkAboutPLANS Max Storage 1748 Mountain View Court 2022-01-06PROJECT LOCATION SO U T H S A I N T V R A I N FIS H C R E E K R O A D 18-HOLE GOLF COURSE TO E S T E S PA R K TO A L L E N S PA R K PEAK VIEW DR. ACACIA DR. R Know what's below. Call before you dig. CALL 3-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. NOT TO SCALE VICINITY MAP MAP TAKEN FROM TOWN OF ESTES PARK DIGITAL MAP 1) ZONING - CH- COMMERCIAL HEAVY 2) SETBACKS - 15 FEET FROM STREETS (25 FEET FROM ARTERIAL), 0 FEET FROM REAR AND 0 FEET FROM SIDES. 3) ALL EXTERIOR LIGHTING SHALL BE SHIELDED AND DOWNCASTING; (REFER TO ESTES VALLEY DEVELOPMENT CODE CHAPTER (EVDC) 7, SECTION 7.9 ). ALL STREET LIGHTS WILL NOT EXCEED 15 FT IN HEIGHT. 4) ALL DISTURBED AREAS WILL BE RESEEDED OR SODDED WITH NATIVE GRASSES/WILDFLOWER MIX. ALL NEW TREES AND SHRUBS WILL BE MAINTAINED IN A HEALTHFUL CONDITION. ALL AREAS WILL BE IRRIGATED. 5) TRASH ENCLOSURES WILL BE SCREENED WITH A SOLID FENCE AND ANIMAL RESISTANT. 6) CONTRACTORS MUST CALL UTILITIES NOTIFICATION CENTER OF COLORADO PRIOR TO EXCAVATING (1-800-922-1987). 7) THE BUILDING HEIGHT WILL BE WITHIN THE LIMITS SET FORTH IN THE REVISED HEIGHT MEASUREMENT PROVISION OF THE EVDC. 8) ALL INTERSECTIONS SHALL HAVE STOP SIGNS INSTALLED TO M.U.T.C.D. STANDARDS. 9) ALL REQUIRED IMPROVEMENTS SHALL BE COMPLETED OR GUARANTEED IN ACCORDANCE WITH EVDC 7.12 AND 10.5.K PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY 10) THE OWNER SHALL BE REQUIRED TO PROVIDE FOR HANDICAP ACCESSIBILITY IN ACCORDANCE WITH THE A.D.A., I.B.C. AND EVDC 7.11.J REQUIREMENTS. 11) CONTOURS ARE 1-FOOT INTERVAL. 12) CONDUITS, METERS, VENTS AND OTHER MECHANICAL EQUIPMENT ATTACHED TO THE BUILDING OR PROTRUDING FROM THE ROOF SHALL BE SCREENED, COVERED OR PAINTED TO MINIMIZE VISUAL IMPACT. 13)NOTICE FROM TOWN OF ESTES PARK PUBLIC WORKS (08/24/2020): IT IS ACKNOWLEDGED THAT THE EXISTING ELLIPTICAL CULVERT REQUIRES MAINTENANCE IN ORDER TO SERVE THE PROPOSED DEVELOPMENT. COORDINATION WITH PUBLIC WORKS DURING CONSTRUCTION WILL AIM TO RESTORE THE DOWNSTREAM CONVEYANCE CAPACITY. SITE PLAN DEVELOPMENT NOTES: 1) A PRIVATE WATER LINE EXTENSION WILL BE REQUIRED FOR DOMESTIC SERVICE FIRE PROTECTION. THIS INFRASTRUCTURE MUST BE INSTALLED; TESTING PERFORMED/PASSED AND ACCEPTED BY THE DIVISION PRIOR TO ISSUANCE OF ANY BUILDING PERMITS. ANY PROJECT PHASING OF THE INFRASTRUCTURE MUST BE SUBMITTED WITH THE CONSTRUCTION DRAWINGS FOR APPROVAL PRIOR TO CONSTRUCTION. PHASED INFRASTRUCTURE MUST BE COMPLETED AND ACCEPTED PRIOR TO ISSUANCE OF ANY BUILDING PERMITS WITHIN THE PHASE. 2) CONSTRUCTION DRAWINGS MUST BE SUBMITTED FOR REVIEW, APPROVAL AND SIGNATURES BY THE UTILITIES DIRECTOR OR HIS DESIGNATED REPRESENTATIVE. NO INSTALLATION OF ANY PROJECT INFRASTRUCTURE IS ALLOWED UNTIL THE CONSTRUCTION DRAWINGS HAVE BEEN SIGNED. ALONG WITH THE SUBMISSION OF THE CONSTRUCTION DRAWINGS PROVIDE THE CONTACT INFORMATION OF THE FIRM OR PERSON ACTING AS UTILITY CONSTRUCTION MANAGER FOR THE PROJECT. 3) CONSTRUCTION DRAWINGS MUST INCLUDE: ·PLAN AND PROFILE TO SHOW POTENTIAL CONFLICTS BETWEEN WATER AND OTHER UTILITIES INCLUDING CULVERTS, SHOW UTILITY EASEMENT LOCATIONS WHEN UTILITY IS NOT IN ROAD RIGHT OF WAY. ·METERING/TAP LOCATION PLAN (DRAWING) INDICATING TAP LOCATIONS AND SIZES, WATER METER LOCATIONS AND SIZES, AND BUILDINGS SERVED BY EACH. 4) ALL WATER LINE DESIGN AND CONSTRUCTION SHALL BE DONE ACCORDING TO THE WATER UTILITY POLICIES AND STANDARDS. 5) BACKFLOW PREVENTION DEVICES WILL BE REQUIRED AT SOME LOCATIONS, CONTACT THE CROSS-CONNECTION CONTROL SPECIALIST AT 970-577-3625 TO DISCUSS AND REVIEW THE REQUIREMENTS RELATING TO POTENTIAL HAZARDS ON THE PROPERTY. 6) THE EXISTING WATER SERVICE LINE(S) MUST BE ABANDONED AT THE TAP WHEN THE NEW PROPOSED FIRE SPRINKLER/SERVICE LINES ARE PLACED IN SERVICE. 7) FOR ANY STRUCTURE REQUIRED TO HAVE A FIRE SUPPRESSION SYSTEM, A DETAILED DRAWING MUST BE TURNED IN TO THE WATER DIVISION NOTING: ·LOCATION, SIZING AND TYPE OF BACKFLOW PREVENTION DEVICE(S) ·ENGINEERED FLOW REQUIREMENTS FOR THE FIRE SPRINKLER SYSTEM, PIPE SIZE BASED ON NFPA TABLE 10.10.2.1.3, FIRE FLOW PRODUCED AT A MAXIMUM VELOCITY OF 10FT/SEC. WATER DEPARTMENT NOTES: 2" 4" 6" 8" 10" PIPE SIZE FLOW RATE 12" 100 GPM 390 GPM 880 GPM 1560 GPM 2440 GPM 3520 GPM 8) SPILL CONTROL METHOD MUST BE SHOWN FOR PROPER DISPOSAL OF DISCHARGE FROM THE RELIEF VALVE, INDICATING LOCATION AND SIZING OF DRAINAGE CAPABLE OF ACCOMMODATING THE DISCHARGE THAT COULD OCCUR. 9) FIRE SUPPRESSION LINES REQUIRE BOTH A CHLORINATION AND PRESSURE TEST, CONDUCTED BY A REPRESENTATIVE OF THE WATER DIVISION PRIOR TO ACCEPTANCE. ANY FIRE SUPPRESSION LINE SERVICING A BUILDING FROM THE WATER MAIN IS A PRIVATE SERVICE LINE AND MUST BE NOTED AS SUCH ON THE DEVELOPMENT PLAN AND THE SUBDIVISION PLAT. FUTURE REPAIR OR MAINTENANCE REQUIRED ON THIS SERVICE IS THE SOLE RESPONSIBILITY OF THE PROPERTY OWNER. FIRE SUPPRESSION LINES REQUIRE A STATE CERTIFIED FIRE LINE INSTALLER AND MUST HAVE THE APPROPRIATE FORMS COMPLETED AND SUBMITTED TO THE ESTES VALLEY FIRE MARSHALL. 10) ALL CONSTRUCTION AND PROCESSES SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE INTERNATIONAL FIRE CODE (2009 EDITION), THE INTERNATIONAL BUILDING CODE (2009 EDITION) AND TOWN OF ESTES PARK CODES AND STANDARDS. 1) PLEASE SCHEDULE A REQUIRED MEET AT SITE WITH JOE LOCKHART, LINE SUPERINTENDENT AT (970)577-3613. 2) ALL TRENCHING AND CONDUIT WILL BE PERFORMED AND INSTALLED BY THE TOWN OF ESTES PARK LIGHT AND POWER DIVISION. THIS WILL BE INVOICED TO THE DEVELOPER. 3) SERVICE LINE TRENCHING & CONDUIT (BETWEEN THE METER AND THE BUILDING) TO BE PROVIDED AND INSTALLED BY DEVELOPER TO TOWN SPECIFICATIONS. 4)LIGHT AND POWER REQUIRES ONE 1½” ORANGE PVC SPARE CONDUIT FROM THE JUNCTION BOX/TRANSFORMER INTO THE BUILDING AT LIGHT AND POWER'S EXPENSE. 5) UTILITY PEDESTALS MUST BE SPACED AT A MINIMUM OF ONE FOOT APART. 6) TRANSFORMERS CANNOT BE PLACED MORE THAN 250 FEET FROM THE BUILDING BEING SERVICED. 7) ALL NEW METER CANS MUST HAVE A BYPASS. 8) ALL INFRASTRUCTURES MUST BE PAID IN ADVANCE TO THE TOWN OF ESTES PARK. NO BUILDING PERMITS WILL BE APPROVED BY LIGHT & POWER UNTIL SUCH TIME. 9) ALL NEW CONSTRUCTION MUST BE UNDERGROUND. 10) ALL OTHER MATERIAL WILL BE PURCHASED FROM & INSTALLED BY THE TOWN OF ESTES PARK. 11) ALL TOWN OF ESTES PARK LIGHT AND POWER LINES, (PRIMARY/SECONDARY) MUST HAVE A 20 FT. UTILITY EASEMENT. THIS EASEMENT CAN BE SHARED BY WATER, PHONE AND CABLE. 12) WATER MUST BE AT LEAST 4FT FROM ELECTRIC. 13) ALL SERVICES MUST BE ON THE OWNER'S PROPERTY OR BE WITHIN A DESIGNATED EASEMENT. 14) THE SIZE OF THE SERVICE MUST BE SHOWN ON THE ELECTRICAL DRAWINGS. 15) ALL EXISTING LINES MUST BE SHOWN ON THE ELECTRICAL DRAWINGS. 16) TRANSFORMERS/JUNCTION BOXES MUST BE IN AN EASEMENT, OR IF POSSIBLE ON THE PROPERTY LINE. 17) ALL PRIMARY LINES MUST BE 4FT DEEP WITH RED WARNING TAPE AT 2FT. 18) ALL SUBDIVISION MUST BE DESIGNED BY AN ELECTRICAL ENGINEER. 19) ALL PIPES MUST BE SCHEDULE 40 GRAY PVC PIPE. ALL CONDUIT MUST BE PUT INTO A PIPE RACK. THERE MUST BE 2-2INCH, 2-4INCH AND 2-6INCH CONDUITS IN A PRIMARY TRENCH. 20) TOWN MUST HAVE OWNERSHIP OF ALL ROAD CROSSINGS. 21) ON UNDERGROUND ELECTRIC SERVICES, IT WILL BE THE ELECTRICIAN'S RESPONSIBILITY TO DIG THEM INTO THE TRANSFORMERS OR PEDESTALS. 22) THE ELECTRICIAN WILL NEED TO SCHEDULE WITH L&P TO UNLOCK AND OPEN TRANSFORMERS OR PEDESTALS. 23) ALL TEMPORARY AND PERMANENT ELECTRIC SERVICES WILL BE CONNECTED BY LIGHT & POWER WITHIN 5 BUSINESS DAYS AFTER THE STATE ELECTRICAL INSPECTION & FEES ARE PAID. 24) PERMANENT METER SOCKETS MUST BE PERMANENTLY MARKED WITH ADDRESS OR UNIT NUMBER. 25) ALL SPARE CONDUITS WILL BE PROVIDED BY LIGHT AND POWER AND TO BE INSTALLED BY THE DEVELOPER AT THEIR COST. LIGHT AND POWER WILL NOT REIMBURSE CONTRACTOR OR DEVELOPER FOR CONDUIT OBTAINED ELSEWHERE. LIGHT & POWER DEPARTMENT NOTES: COVER SHEET CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 1954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 14. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF THE IMPROVEMENTS SHALL MEET OR EXCEED THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CONTRACT DOCUMENTS. 15. THE CONTRACTOR SHALL HAVE, ON-SITE AT ALL TIMES, ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB, AND EASEMENTS. 16. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 17. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS, SHOWN ON THESE DRAWINGS, OR DESIGNATED TO BE PROVIDED, INSTALLED, OR CONSTRUCTED, UNLESS SPECIFICALLY NOTED OTHERWISE. 18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT NO MUD OR DEBRIS SHALL BE TRACKED ONTO THE EXISTING PUBLIC STREET SYSTEM. MUD AND DEBRIS MUST BE REMOVED WITHIN 24 HOURS BY AN APPROPRIATE MECHANICAL METHOD (I.E. MACHINE BROOM SWEEP, LIGHT DUTY FRONT-END LOADER, ETC.) OR AS APPROVED BY THE LOCAL ENTITY STREET INSPECTOR. 19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET OR RECORD DRAWINGS KEPT ON THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL ENTITY'S INSPECTOR AT ALL TIMES. THIS INFORMATION SHALL BE PROVIDED TO PROJECT MANAGER UPON COMPLETION OF THE PROJECT. 20. AREAS DISTURBED BY GRADING SHALL BE CONTOURED SO THEY CAN BE REVEGETATED AND SHALL BE REVEGETATED WITHIN ONE (1) GROWING SEASON AFTER CONSTRUCTION, USING NATIVE SPECIES SIMILAR TO THOSE GROWING ON THE SITE WHEN SUCH REVEGETATION DOES NOT CONTRIBUTE HAZARDS. REVEGETATION SHALL BE SUFFICIENT TO PROVIDE EROSION CONTROL AND TO PREVENT THE INVASION OF WEEDS. 21. ON MAN-MADE SLOPES OF TWENTY-FIVE PERCENT (25%) OR GREATER, PLANT MATERIALS WITH DEEP ROOTING CHARACTERISTICS SHALL BE SELECTED THAT WILL MINIMIZE EROSION AND REDUCE SURFACE RUN-OFF. 22. THE FIRE ALARM ROUGH WIRING SHALL BE INSPECTED AND APPROVED BY DORA ELECTRICAL INSPECTOR PRIOR TO COVERING OF SYSTEM WIRING. PERMIT FOR FIRE ALARM WIRING MUST BE OBTAINED FROM THE DORA ELECTRICAL PROGRAM. 23. DEFERRED SUBMITTALS INCLUDE: PRE-ENGINEERED ROOF TRUSS PLAN. 24. DEFERRED SHOP DRAWING SUBMISSION IS REQUIRED FOR THE FIRE PROTECTION SYSTEM. DEFERRED SUBMISSION SHALL BE PROVIDED TO THE AUTHORITY HAVING JURISDICTION FOR REVIEW AND APPROVAL. 1. DEPTH OF MOISTURE-DENSITY CONTROL FOR THIS PROJECT SHALL BE AS FOLLOWS: FULL DEPTH OF ALL EMBANKMENTS BASES OF CUTS AND FILLS 0.5 FEET 2. EXCAVATION REQUIRED FOR COMPACTION OF BASES OF CUTS AND FILLS WILL BE CONSIDERED SUBSIDIARY TO THAT OPERATION AND WILL NOT BE PAID SEPARATELY. 3. WATER SHALL BE USED AS A DUST PALLIATIVE WHERE REQUIRED. LOCATIONS SHALL BE AS ORDERED. COST FOR DUST PALLIATIVE WILL NOT BE MEASURED OR PAID FOR SEPARATELY BUT SHALL BE INCLUDED IN THE WORK. 4. THE CONTRACTOR SHALL PROTECT ALL WORK AREAS AND FACILITIES FROM WATER AT ALL TIMES. AREAS AND FACILITIES SUBJECT TO FLOODING, REGARDLESS OF THE SOURCE OF WATER SHALL BE PROMPTLY DEWATERED AND RESTORED AT NO COST TO THE TOWN. 5. RELOCATION OF EXISTING UTILITIES IS NOT PART OF THIS CONTRACT EXCEPT AS SHOWN ON THESE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF UTILITY RELOCATIONS BY UTILITY COMPANIES IN HOW IT IMPACTS HIS WORK SCHEDULE AND WORK PROGRESS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING UTILITIES DURING CONSTRUCTION AND SHALL HOLD THE DEVELOPER AND IT'S ENGINEER HARMLESS FOR DAMAGES ARISING FROM THE CONTRACTOR'S FAILURE TO ADEQUATELY PROTECT EXISTING UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SCHEDULE UTILITY ADJUSTMENTS TO ELIMINATE CONFLICT WITH PROGRESS OF THE WORK. 6.UTILITIES SANITARY SEWER: UPPER THOMPSON SANITATION DISTRICT CONTACT: NATHAN ROMIG (970) 692-4237 ELECTRIC: ESTES PARK POWER AND COMMUNICATIONS CONTACT: JOE LOCKHART (970) 577-3607 WATER: TOWN OF ESTES PARK CONTACT: CHRIS ESHELMAN (970) 577-3630 UTILITY LOCATE: 1-800-922-1987. 7. TRENCHES OVER FIVE FEET IN DEPTH SHALL BE EITHER SHORED OR TRENCH WALLS SHALL BE SLOPED TO THE APPLICABLE OSHA REGULATIONS. 8. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPROPRIATE OSHA REGULATIONS AND STANDARDS INCLUDING, BUT NOT LIMITED TO, 29 CFR PART 1926, OSHA STANDARDS-EXCAVATIONS. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF SLOPING AND BENCHING FOR PROTECTION OF EMPLOYEES IN EXCAVATIONS PLUS METHODS FOR PHYSICAL PROTECTION FOR FALL PROTECTION. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING, AT HIS EXPENSE, ANY PROPERTY PINS OR SURVEY MONUMENTS DESTROYED DURING CONSTRUCTION. 10. OVERHEAD POWER AND TELEPHONE LINES ARE SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTING OVERHEAD UTILITIES LOCATIONS AND TAKING NECESSARY PRECAUTIONS TO PREVENT INTERFERENCE WITH OVERHEAD LINES PRIOR TO AND DURING CONSTRUCTION. 11. THE CONTRACTOR SHALL COORDINATE WITH EMERGENCY ASSISTANCE AGENCIES TO INSURE THAT EMERGENCY VEHICLES ARE NOT HINDERED DURING CONSTRUCTION. 12. THE PHYSICAL FEATURES WITHIN THE LIMITS OF THE PROJECT HAVE BEEN SHOWN BASED ON THE BEST AVAILABLE INFORMATION. 13. EXISTING UTILITIES: KNOWN SEWER, WATER, GAS MAINS, TELEPHONE CONDUITS, ELECTRIC CABLES, AND OTHER UNDERGROUND STRUCTURES ARE SHOWN ON THE DRAWINGS ONLY TO THE EXTENT SUCH INFORMATION HAS BEEN MADE AVAILABLE TO OR DISCOVERED BY THE ENGINEER. THERE IS EXPECTED TO BE DISCREPANCIES AND OMISSIONS IN THE LOCATION AND QUANTITY OF UTILITIES AND STRUCTURES SHOWN. THIS INFORMATION IS SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR BUT IS NOT GUARANTEED TO BE EITHER CORRECT OR COMPLETE. THE CONTRACTOR WILL MAKE THE INVESTIGATION DEEMED NECESSARY TO VERIFY THE CORRECTNESS AND EXTENT OF THE UTILITIES. THE CONTRACTOR SHALL, AHEAD OF EXCAVATION, LOCATE ALL UNDERGROUND UTILITIES AND STRUCTURES SO THEY WILL NOT BE ACCIDENTALLY DAMAGED DURING CONSTRUCTION. THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY AND LIABILITY FOR ANY DAMAGE TO UNDERGROUND UTILITIES AND STRUCTURES. GENERAL NOTES:GENERAL NOTES (CONT'D): PLAN NOTES: CORNERSTONE ENGINEERING AND SURVEYING, INC. IS NOT A GUARANTOR OF THE PERFORMANCE OF THE WORK. CORNERSTONE ENGINEERING AND SURVEYING, INC. IS NOT RESPONSIBLE FOR SAFETY, IN, ON, OR ABOUT THE PROJECT SITE, NOR FOR COMPLIANCE BY THE APPROPRIATE PARTY WITH ANY REGULATIONS RELATED THERETO. CORNERSTONE ENGINEERING AND SURVEYING, INC. EXERCISES NO CONTROL OVER THE SAFETY OR ADEQUACY OF ANY EQUIPMENT, BUILDING COMPONENTS, FORMS, OR OTHER WORK AIDS USED IN OR ABOUT THE PROJECT, OR OVER THE SUPERINTENDING OF THE SAME. WRITTEN SCALES ON PLAN ARE FOR FULL SIZED 24" x 36" PLANS AND DO NOT APPLY TO REDUCED PLAN SETS. JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/2021 1 1 1 Michael Todd, P.E. 2021.12.1 4 16:39:35 -07'00' APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 01/06/2022 THIS STRUCTURE MUST COMPLY WITH THE REQUIREMENTS OF THE 2020 NATIONAL ELECTRICAL CODE X X X X X X X X X X X X X X X X X XX O H P O H P 1800 SF FF=7590.75 800 SF FF=7591.25 800 SF FF=7592.25 800 SF FF=7592.75 1600 SF FF=7593.25 880 SF FF=7593.25 45.0 40 . 0 20.0 20 . 0 80 . 0 22 . 0 40.0 40.0 40 . 0 10' UTILITY & DRAINAGE EASEMENT 10' UTILITY & DRAINAGE EASEMENT 15' BUILDING SETBACK 11'± 15.9'± EXISTING 21" ELLIPTICAL CULVERT U.S.INV= 7682.33 D.S INV= 7680.62 (SEE NOTE #13) ACACIA DRIVE OH P OH P OH P 7700 7 6 9 5 76 9 5 7 6 9 5 7690 769 0 76 9 0 7 6 8 5 76 8 5 S 86°00'00" E 200.00' S 0 4 ° 2 5 ' 1 0 " W 2 8 . 9 6 ' N 0 0 ° 4 7 ' 2 0 " W 1 4 4 . 0 6 ' N 0 0 ° 4 8 ' 3 8 " W 1 5 0 . 2 1 ' N 48 ° 5 9 ' 0 5 " E 1 5 6 . 6 7 ' 3 2 .2 6 ''''''''''''''''''''''''''''''''''''''''' C H =S 8 7 °5 2 '1 6 " EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE R =5 7 0 .0 0 ''''''''''''''''''''''''''''''''''''''''' L =3 2 .2 6 ''''''''''''''''''''''''''''''''''''''''' D =3 °1 4 '3 5 """"""""""""""""""""""""""""""""""""""""" 6 4.50''''''''''''''''''''''''''''''''''''''''' C H =S 2 9°26'48" WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW R =75.00''''''''''''''''''''''''''''''''''''''''' L =6 6.67''''''''''''''''''''''''''''''''''''''''' D =5 0°56'06""""""""""""""""""""""""""""""""""""""""" 4 3 .2 5'''''''''''''''''''''''''''''''''''''''''C H =S 8 0 °4 9 '59" EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE R =6 0 .00''''''''''''''''''''''''''''''''''''''''' L =4 4 .25''''''''''''''''''''''''''''''''''''''''' D =4 2 °15 '06""""""""""""""""""""""""""""""""""""""""" 103.46''''''''''''''''''''''''''''''''''''''''' C H = N 18°28'38" EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE R =60.00''''''''''''''''''''''''''''''''''''''''' L=124.74''''''''''''''''''''''''''''''''''''''''' D =119°07'17""""""""""""""""""""""""""""""""""""""""" LOT 5 MOUNTAIN TECHNOLOGICAL CENTER ZONED CH-COMMERCIAL HEAVY LOT 7 MOUNTAIN TECHNOLOGICAL CENTER ZONED CH-COMMERCIAL HEAVY LOT 4 ACACIA CORNER ZONED CH-COMMERCIAL HEAVY LOT 1 MOUNTAIN TECHNOLOGICAL CENTER ZONED CH-COMMERCIAL HEAVY 60' PUBLIC RIGHT-0F-WAY 50' PUBLIC RIGHT-0F-WAY 44' 20.00 20' ASPHALT SURFACE EXI S T I N G W O O D R A M P 800 SF FF=7593.25 20.0 20.0 20.0 20.0 800 SF FF=7591.75 20 . 0 20 . 0 800 SF FF=7593.25 800 SF FF=7593.25 800 SF FF=7593.25 RO O F R I D G E EL = 7 6 1 6 . 4 ± 92.05X 91.25X 90.03X R10.00 R25.00 (7687.6)X (7687.2)X 90.96 X 6 . 7 5 % 8 . 2 % 91X 90X 89X 88X 3.4% 4.5% 1.50% PROPOSED GRASS LINED DRAINAGE SWALE @ 2.0% 90 X 92.73X2.0% 3.5% 91.63X 90.63X 4. 6 % 93.13X 93.13X 92.63X 92.63X 92.13X 92.13X 91.63X 91.63X 91.13X 91.13X 90.63X 90.63X 90.63 XINV=90.97X INV=89.23X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X 93.13X R8.00 R25.0089X 3. 0 % (7687.7)X (7687.2)X (7686.1)X (7687.5)X (7687.6)X (7687.3)X ASPHALT SURFACE 9 6 S S S S S S T 9 7 9 8 9 8 9 5 9 4 9 3 9 2 91 90 89 88 91 9092 93 93 92 92 91 95 96 9 4 9 5 97 PROPOSED CONCRETE CURB & GUTTER PROPOSED CONCRETE CURB & GUTTER 23' 14.4'± BUILDING 'A' PROPOSED SELF STORAGE UNITS EXISTING ASPHALT ROADWAY MOUNTAIN VIEW COURT EXISTING 8" SEWER MAIN PROPOSED RIPRAP DRAINAGE SWALE 19.50 (TYP.) 9.00 8.00 5.00 24.3 3 15' BUILDING SETBACK PROPOSED 5-FOOT SI D E W A L K W W W W W EX I S T I N G 6 " W A T E R L I N E 10' UTILITY & DRAINAGE EASEMENT PROPOSED 25 KVA TRANSFORMER EXISTING GUY-WIRE TO BE MODIFIED SS SS SS SS SS PROPOSED FIRE LINE & WATER SERVICE (FIRE LINE SIZE TO BE DETERMINED DURING FIRE SUPPRESSION DESIGN) PROPOSED 4" SEWER SERVICE PROPOSED CONCRETE PAN TO PROMOTE STORM FLOWS FROM ACACIA TO BE DIRECTED TO THE EXISTING CULVERT PROPOSED ACCESSIBLE RAMP W/ DETECTABLE WARNING 9 3 9 2 9 1 9 0 TOW 88.5 BOW 86 TOW 88.5 BOW 86 PROPOSED WATER QUALITY POND DETENTION BASIN 2 ~763 CF88 87 86 TOW 89 BOW 87 PROPOSED WATER QUALITY POND DETENTION BASIN 1 ~692 CF 92.30 X 92.05X92.30X PROPOSED 40LF 15" ADS CULVERT @ 1.0% U.S.INV=7588.64 D.S.INV=7588.24 PROPOSED 74 LF 15" ADS CULVERT @ 1.0% US. INV= 7588.24 D.S. INV =7587.50 PROPOSED NYOPLAST MANHOLE PRODUCT No. 2836AG10 OR APPROVED EQUAL RIM=7591.5 INV=7588.24 1600 SF FF=7593.25 FG 94.0 X 93.0 X 93.0 X TOW 98.5 BOW 94.5 TOW 98.0 BOW 93.0 93 TOW 94.0 BOW 93.0 PROPOSED DRY-STACK ROCK WALLPROPOSED CONCRETE RETAINING WALL BUILDING 'B' PROPOSED SELF STORAGE UNITS 85 PROPOSED RECYCLED ASPHALT PROPOSED DRY STACK RETAINING WALL 89X 90X 91X 92.2 X 92.75 X 92.75 X 1.4% (MAX.) 12' B E T W E E N EAV E S SUBJECT PROPERTY LINE BUILDING SETBACK LINE EXISTING EASEMENT AS NOTED EXISTING INDEX CONTOUR EXISTING INTERMEDIATE CONTOUR W EXISTING WATER LINE S EXISTING SEWER LINE G EXISTING GAS LINE 5020 EXISTING TELEPHONE PED EXISTING POWER POLE EXISTING SEWER MANHOLE EXISTING TREE (TYP.) X X X X X X EXISTING FENCE PROPOSED SEWER CLEANOUT WOVEN GEOTEXTILE FABRIC MEETING: ASTM D4751-AOS US STD SIEVE #50 TO #70, ASTM D4633 MIN. TRAPEZOIDAL TEAR STRENGTH 100x60 LBS, MINIMUM COE SPECIFIED OPEN AREA OF 4% 4" Ø PERFORATED HDPE PIPE 3.0 FT. MIN. LINER OVERLAP 18" MIN. ASTM C 33 SAND WRAP ALL GEOTEXTILE FABRIC AND IMPERMEABLE LINERS TO THE TOP OF SAND LAYER. SECURLEY ATTACH TO WALLS OR SIDES OF BASIN. RIPRAP OUTLET PROTECTION 8" MIN. GRAVEL LAYER THAT MEETS CDOT SPECIFICATION 703 FOR AGGREGATE No. 3,4, OR 67. (AASHTO MR43 No. 3,4, OR 67) 3 D MIN. D NONWOVEN GEOTEXTILE (SEE SPECIFICATION IN PROFILE VIEW) 4" 3" 8" M I N . GR A V E L LA Y E R 18 " M I N . AS T M C 3 3 SA N D 4" Ø PERF. HDPE PIPE R Know what's below. Call before you dig. CALL 3-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. SITE PLAN CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 2954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459 JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/2021 LEGEND: 6040200 SCALE 1" = 20' 20 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 2. INSTALL PERMANENT BLOCKING UNDER TAPPING VALVE PRIOR TO WET TAP. BELL, COUPLING, VALVE OR OTHER OBSTRUCTIONS. 1. TAPPING SLEEVE SHALL BE PLACED A MINIMUM OF 24" FROM ANY NOTES: TAPPING VALVE C THRUST BLOCK NEW WATER EXISTING TOWN MAIN TAPPING SLEEVE FOR WET TAP TO BE TAPPED L LC MAIN TYPICAL TAPPING SLEEVE & VALVE DETAIL NOT TO SCALE 2621DOUBLE GRADE CLEANOUT NOT TO SCALE GRAVITY SEWER UTSD DETAIL REF. # PROPOSED 6" GATE VALVE PROPOSED 6" D.I.P. FIRE LINE PROPOSED 1-1/2" CURB STOP MECHANICAL ROOM 5' MAX. PROPOSED 6" GATE VALVE PROPOSED 1-1/2" 'K' COPPER WATER SERVICE PROPOSED SERVICE INSULATOR PROPOSED 1-1/2" CORP STOP BRASS SERVICE SADDLE FIRE LINE SERVICE TAPPING DETAIL NOT TO SCALE MIN. COVER TO RIGID PAVEMENT, H 6" FOR 30"-60" PIPE SPRINGLINE SIDEWALK/CURB AND GUTTER TYPICAL DETAIL NOT TO SCALE FILTRATION POND DETAIL NOT TO SCALE TYP. FILTRATION POND SECTION NOT TO SCALE TYPICAL PIPE TRENCH DETAIL NOT TO SCALE 1 1 1 Michael Todd, P.E. 2021.12.1 4 16:39:10 -07'00' Reviewed by SAFEbuilt 01/06/2022 16 ' - 0 " 16 ' - 0 " 23 ' - 2 " 16 ' - 0 " 40'-0" 12 4 0'-6" 16 ' - 0 " 12 4 0'-6" EXISTING GRADE EXISTING GRADE 20'-0" 12'X14' GARAGE DOOR 8'-0" SHEARWALL PER LINE 1 IN BRACED WALL SCHEDULE SHEARWALL PER LINE 1 IN BRACED WALL SCHEDULE SHEARWALL PER LINE 1 IN BRACED WALL SCHEDULE SHEARWALL PER LINE 1 IN BRACED WALL SCHEDULE 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 12'X14' GARAGE DOOR 3068 MAN DOOR 3068 MAN DOOR 12'X14' GARAGE DOOR 8'x10' GARAGE DOOR 3068 MAN DOOR 3068 MAN DOOR BUILDING ELEVATIONS CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 3954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459R Know what's below. Call before you dig. CALL 3-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. JLRAGENCY COMMENTS 08/03/202008/17/2020 JLRREVISE PROPERTY ADDRESS09/15/2020 EAST ELEVATION SCALE 1/8" = 1'-0" SOUTH ELEVATION SCALE 1/8" = 1'-0" WEST ELEVATION SCALE 1/8" = 1'-0" NORTH ELEVATION SCALE 1/8" = 1'-0" MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 BUILDING A BUILDING B BUILDING B BUILDING A JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/2021 Michael Todd, P.E. 2021.12.1 4 16:38:52 -07'00' Reviewed by SAFEbuilt 01/06/2022 FF=7590.75 FF=7591.25 FF=7592.25 FF=7592.75 FF=7591.75 40 ' 20'-61 4" 20'-61 4" 20'-61 4" 20'-61 4" 5'-81 4" 5'-11 2" 8'-61 2" 5'-11 2" 5'-11 2" 2'-10" TOW 96.25 TOF 90.75 TOW 95.25 TOF 90.25 TOW 94.25 TOF 91.75 TOW 93.25 TOF 90.50 TOW 92.25 TOF 89.50 TOW 90.75 TOF 86.50 TOW 91.25 TOF 87.25 40 ' - 0 " FF=7593.25 TOW 93.25 TOF 90.75 TOW 92.75 TOF 90.25TOW 93.25 TOF 90.75 TOW 92.25 TOF 91.75TOW 92.75 TOF 89.25 TOW 91.75 TOF 89.25TOW 92.25 TOF 89.75 TOW 91.25 TOF 88.75TOW 91.75 TOF 89.25 TOW 90.75 TOF 88.25TOW 91.25 TOF 88.75 TOW 90.75 TOF 86.50 TOW 90.75 TOF 88.25 A A ' A A ' A A ' A A' A A'C C' C C' C C' C C' C C' 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 45'-0" 3068 DOOR 12'-6" 12'-61 2" 30'-0" 20'-0" 20'-0" 20' 20'-0" 10'-0" 145'-0" (2' MIN.) 2" POLYSTYRENE INSULATION 5' - 8 " 4'-8" D D' 162'-0" 40 ' - 0 " FF=7593.25 FF=7593.25 40 ' - 0 " TOW 98.25 TOF 92.92 TOW 97.25 TOF 92.92 TOW 96.25 TOF 92.92 TOW 97.25 TOF 92.92 TOW 96.25 TOF 92.92 TOW 95.25 TOF 92.92 TOW 94.25 TOF 91.98 TOW 93.25 TOF 90.92 36 ' - 4 " 25 ' - 1 0 " 143'-10" 72'-0" TOW 93.25 TOF 90.75 AA' A A' A A ' A A ' BB' BB' BB' BB' BB' 12'X14'' GARAGE DOOR 20'-0" 20'-0"20'-0"40'-0"40'-0"22'-0" 3068 DOOR 69'-61 4" 39'-61 4" 79'-61 4" 20'-0"20'-0"20' 20'-0"16'-0"7'-0"9'-0" 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 8'X10'' GARAGE DOOR FI R E RI S E R (2' MIN.) 2" POLYSTYRENE INSULATION4'-8" 5' - 8 " DD' SECTION A-A' NOT TO SCALE WALL DETAIL A 8" 8" #4 @18" OC HORIZONTAL W/ (3) BAR MIN. (3) #4 REBAR CONT. #4 REBAR @ 48" O.C. WALL < 4' FF/TOW EL = PER PLAN FOOTER TO UNDISTURBED SOIL OR BEDROCK 4" CONCRETE SLAB w/ 6x6 W1.4xW1.4 WELDED WIRE FABRIC REINFORCEMENT (TYP) 4" 36" 600 S 162-97 STUDS @ 24" O.C. SIMPSON RCKW5.5 FASTENING PER DETAIL @ 24" OC W/ 1 2" WEDGE ANCHOR w? 5" MIN. EMBED BOTTOM TRACK 16" 1 2" EXPANSION MATERIAL 6" STRUCTURAL BACKFILL COMPACTED TO 95% PROCTOR SECTION C-C' NOT TO SCALE FND DETAIL C 4" 4" CONCRETE SLAB w/ 6x6 W1.4xW1.4 WELDED WIRE FABRIC OR FIBER MESH REINFORCEMENT (TYP) 4"BLD A=12" 8" (2) #4 REBAR CONT. 1/2"x10" J BOLTS @ 30" O.C. w/ 2"X2" X 3 16" WASHERS 2"x PRESSURE TREATED OR TIMBER STRAND SILL PLATE (TYP.) 2x6 WALL w/ 1 2" GYPSUM SHEATHING EACH SIDE, ATTACH SHEATHING PER BRACE WALL SCHEDULE 2"x PRESSURE TREATED OR TIMBER STRAND SILL PLATE (TYP.) PER PLAN 8" 4" CONCRETE SLAB W/ 4"x4" W1.4xW1.4 WELDED FABRIC FF EL = PER PLAN (3) #4 REBAR CONTINUOUS 1/2"x10" J BOLTS @ 30" O.C. w/ 2"X2"X 3 16" WASHERS 4" SECTION B-B' NOT TO SCALE THICKENED SLAB DETAIL B 2x6 WALL w/ 1 2" GYPSUM SHEATHING EACH SIDE, ATTACH SHEATHING PER BRACE WALL SCHEDULE NOTES* HOLDDOWN (HD) SCHEDULE HD # MANUF. / MODEL 1 HD'S AS SHOWN ARE IN APPROXIMATE LOCATIONS. FIELD LOCATE HD'S AT CORNERS, EDGE OF OPENINGS ABOVE, OR ENDS OF REQUIRED SHEAR WALLS (SEE ARCH PLANS FOR DIMENSIONS) SYMBOL SIMPSON STHD14 1 1. ALL EXTERIOR SHEATHING TO BE SET PERPENDICULAR TO SUPPORTS, VERTICAL EDGES SHALL FALL UPON 6", 12 GAUGE STUDS (6X1.625C) SPACED 24" O/C TYP (SEE PLAN). 2. HORIZONTAL JOINTS SHALL OCCUR OVER BLOCKING EQUAL IN SIZE TO THE STUDDING EXCEPT WHERE WAIVED BY THE INSTALLATION REQUIREMENTS FOR THE SPECIFIC SHEATHING MATERIAL SHOWN ABOVE. BRACED WALL PANEL SCHEDULE - STUDS @ 16" NOTES: BLOCKED?DESIGNATION ALL EXTERIOR UNLESS NOTED OTHERWISE OSB or PLYWOOD EXTERIOR ONLY (NOTE 2) 7/16"YES SHTH. THICKNESSWALLRATED STRUC. SHEATHING TYPE EDGES HORIZONTAL MINIMUM CONNECTOR TYPE (OR EQUAL) 12"6" FIELD SPACINGEDGE SPACING (NOTE 2) 7/16"YES #8 SCREW (STEEL STUDS) 12"4" OSB or PLYWOOD EXTERIOR ONLY 0.12" NAIL X 15 8" MIN or #6 SCREWS GYPSUM BOARD BOTH SIDES 1/2" YES 7"7" INDICATES SIMPSON HOLD-DOWN STRAP. ATTACH PER DETAILS. 1 (NOTE 2) #8 SCREW (STEEL STUDS) ALL PARTITION WALLS 1-12" end distance #4 rebar continuous SIMPSON Strong-Ti e â Typical STHD Corner Installation DESIGN CRITERIA ALL CONSTRUCTION METHODS PER 2015 IBC RISK CATEGORY = I ELEVATION = 7650 LIVE FLOOR LOAD = 250 PSF SNOW GROUND SNOW LOAD = 67 PSF SNOW LOAD IMPORTANCE FACTOR = 0.80 SNOW EXPOSURE = 1.0 THERMAL FACTOR = 1.2 ROOF SNOW LOAD = 45.02 PSF WIND ULTIMATE WIND LOAD = 175 MPH (3 SECOND GUST, EXPOSURE C) WIND IMPORTANCE FACTOR = 1.0 ALTITUDE CORRECTION FACTOR = 0.80 SEISMIC MINIMUM SEISMIC DESIGN CATEGORY = B SEISMIC IMPORTANCE FACTOR = 1.0 SEISMIC COEFF (Fa*Ss) = 0.34 SECTION D-D' NOT TO SCALE WALL DETAIL D 8" 8" #4 @18" OC HORIZONTAL W/ (3) BAR MIN. (3) #4 REBAR CONT. #4 REBAR @ 48" O.C. WALL < 4' FF/TOW EL = PER PLAN FOOTER TO UNDISTURBED SOIL OR BEDROCK 4" CONCRETE SLAB w/ 6x6 W1.4xW1.4 WELDED WIRE FABRIC REINFORCEMENT (TYP) 4" 36" 600 S 162-97 STUDS @ 24" O.C. W/ R19 (MIN.) INSULATION SIMPSON RCKW5.5 FASTENING PER DETAIL @ 24" OC W/ 1 2" WEDGE ANCHOR w? 5" MIN. EMBED BOTTOM TRACK 16" 1 2" EXPANSION MATERIAL 6" (2' MIN.) 2" POLYSTYRENE INSULATION STRUCTURAL BACKFILL COMPACTED TO 95% PROCTOR FOUNDATION PLAN CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 4A954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459 R Know what's below. Call before you dig. CALL 3-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 -FOOTINGS- DESIGN OF FOOTINGS IS BASED ON A MAXIMUM ALLOWABLE BEARING PRESSURE OF 3,500 PSF ON THE EXISTING SUBGRADE, BELOW FROST DEPTH BASED ON DEAD LOAD PLUS LIVE LOAD. ALL FOOTINGS TO BE SET ON EXISTING SUBGRADE. REINFORCED CONCRETE: DESIGN IS BASED ON "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"(ACI 318-14). CONCRETE WORK SHALL CONFORM TO "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI 301). STRUCTURAL CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES: DETAILING, FABRICATIONS, AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315-80). WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. REINFORCING BARS SHALL CONFORM TO ASTM A615, AND SHALL BE GRADE 60, EXCEPT TIES OR BARS SHOWN TO BE FIELD-BENT, WHICH SHALL BE GRADE 40. AT SPLICES, LAP BARS 50 DIAMETERS UNLESS NOTED OTHERWISE. AT CORNERS AND INTERSECTIONS, MAKE HORIZONTAL BARS CONTINUOUS OR PROVIDE MATCHING CORNER BARS. AROUND OPENINGS IN WALLS AND SLABS, PROVIDE 2-#5, EXTENDING 2'-0" BEYOND EDGE OF OPENING. IN CONTINUOUS MEMBERS, SPLICE TOP BARS AT MID-SPAN AND SPLICE BOTTOM BARS OVER SUPPORTS. PROVIDE INTERMITTENT SHEAR KEYS AT ALL CONSTRUCTION JOINTS AND ELSEWHERE AS SHOWN ON THE DRAWINGS. EXCEPT AS NOTED ON THE DRAWINGS, CONCRETE PROTECTION FOR REINFORCEMENT IN CAST-IN-PLACE CONCRETE SHALL BE AS FOLLOWS: A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH B. EXPOSED TO EARTH OR WEATHER: #5 BAR, W31 OR D31 WIRE, AND SMALLER C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS:#11 BAR AND SMALLER BEAMS, COLUMNS: PRIMARY REINFORCEMENT STIRRUPS, TIES, SPIRALS ALL REINFORCING STEEL IS TO BE TIED IN PLACE PRIOR TO PLACING CONCRETE. NO WET SETTING OF REINFORCING WILL BE PERMITTED. A REPRESENTATIVE OF THE ENGINEER SHOULD OBSERVE THE FOUNDATION EXCAVATION PRIOR TO FOUNDATION CONSTRUCTION. Intended Use f'c, psi 28day Ratio W/C Aggregate Maximum inches Slump Percent Entrained Air Type Cement Comments Admixtures, I/II2-4%63/4" Stone3,000Footings .5 3/4" StoneWalls 4,500 .45 6%4 I/II 3/4" StoneExt slab on grade 4,500 .45 6%4 I/II 3/4" StoneInt slab on grade 3,500 .5 2-4%4 I/II Fibermesh 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC). THE ABOVE SHALL GOVERN EXCEPT WHERE THE CONSTRUCTION DOCUMENTS ARE MORE RESTRICTIVE. 2. ALL STRUCTURAL BACK FILL MUST BE COMPACTED TO 95% STANDARD PROCTOR. 3. CONTROL JOINTS ARE TO ARE RECOMMENDED @ 10' O.C. IN EACH DIRECTION AND HAVE A MINIMUM DEPTH OF 1". (1 4 DEPTH OF CONCRETE SLAB) 4. ALL FOOTINGS AND PIERS TO BEAR ON EXISTING SUBGRADE. NOTES: 3" 1-1/2" 3/4" 1-1/2" 1-1/2" FOUNDATION DESIGN STATEMENT OF SPECIAL INSPECTIONS: FLOOR SLABS AND FOUNDATION WALLS ARE EXCLUDED FROM THE SPECIAL INSPECTIONS PER IBC 1705.3. FREQUENCY OF CONCRETE STRENGTH TESTS (#6 OF TABLE 1705.3) IS TO BE ONE PER DAY. BUILDING 'A' SCALE 1/8" = 1'-0" BUILDING 'B' SCALE 1/8" = 1'-0" JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/20211 1 1 111 Michael Todd, P.E. 2021.12.1 4 16:38:32 -07'00' Reviewed by SAFEbuilt 01/06/2022 40 ' 40 ' - 0 " 20'-0" 20'-0" 20'-0" 20'-0" 20'-0" 45'-0" 12'-6" 12'-61 2" 30'-0" 20'-0" 20'-0" 20' 20'-0" 10'-0" 145'-0" G 4B 5 G 4B 5 G 4B 5 G 4B 5 G 4B 5 F 4B 5 G 4B 5 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 3068 DOOR PRE-ENGINEERED TR U S S E S @ 24 O.C. 162'-0" 40 ' - 0 " 40 ' - 0 " 20'-0" 20'-0"20'-0"40'-0"40'-0"22'-0" 10'-0"20'-0"20'-0"20'-0"20'-0"20' 20'-0"16'-0"7'-0"9'-0"G 4B 5 G 4B 5 G 4B 5 G 4B 5 G 4B 5 G 4B 5 G 4B 5 E 4B 5 F 4B 5 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 3068 DOOR 12'X14'' GARAGE DOOR 8'X10'' GARAGE DOOR PRE ENGINEERED TRUSSES @ 24" O.C. DESIGN CRITERIA ALL CONSTRUCTION METHODS PER 2015 IBC RISK CATEGORY = I ELEVATION = 7650 LIVE FLOOR LOAD = 250 PSF SNOW GROUND SNOW LOAD = 67 PSF SNOW LOAD IMPORTANCE FACTOR = 0.80 SNOW EXPOSURE = 1.0 THERMAL FACTOR = 1.2 ROOF SNOW LOAD = 45.02 PSF WIND ULTIMATE WIND LOAD = 175 MPH (3 SECOND GUST, EXPOSURE C) WIND IMPORTANCE FACTOR = 1.0 ALTITUDE CORRECTION FACTOR = 0.80 SEISMIC MINIMUM SEISMIC DESIGN CATEGORY = B SEISMIC IMPORTANCE FACTOR = 1.0 SEISMIC COEFF (Fa*Ss) = 0.34 PRE-ENGINEERED TRUSSES REQUIRE DEFERRED SUBMITTAL TO THE BUILDING DEPT. NOTES: ROOF FRAMING PLAN CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 4B954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459 R Know what's below. Call before you dig. CALL 3-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 BUILDING 'B' SCALE 1/8" = 1'-0" JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/20211 ROOF FRAMING PLAN BUILDING 'A' SCALE 1/8" = 1'-0" ROOF FRAMING PLAN Michael Todd, P.E. 2021.12.1 4 16:38:02 -07'00' Reviewed by SAFEbuilt 01/06/2022 40'-0" 16 ' - 0 " WALL SHEATHING PER BRACED WALL SCHEDULE TYVEK WRAP (OR APPROVED EQUAL) 12 4 SIMPSON H7Z HURRICANE TIE EACH END PRE-ENGINEERED TRUSS @ 24" OC TO BEAR ON EXTERIOR WALLS 50 YEAR ARCHITECTURAL SHINGLES OVER 30# FELT, OVER 5 8" SHEATHING (TYP) METAL SIDING 5/8" DRYWALL 5/8" DRYWALL 4" CONCRETE FLOOR ON COMPACTED SUBGRADE 6x1.625 C STUDS @ 24" O.C. 7/16" OSB TO BE PLACED HORIZONTAL TOP TRACK BOTTOM TRACK TRUSSES TO ALIGN WITH STUDS TOP TRACK NOTES* HOLDDOWN (HD) SCHEDULE HD # MANUF. / MODEL 1 HD'S AS SHOWN ARE IN APPROXIMATE LOCATIONS. FIELD LOCATE HD'S AT CORNERS, EDGE OF OPENINGS ABOVE, OR ENDS OF REQUIRED SHEAR WALLS (SEE ARCH PLANS FOR DIMENSIONS) SYMBOL SIMPSON STHD14 1 1. ALL EXTERIOR SHEATHING TO BE SET PERPENDICULAR TO SUPPORTS, VERTICAL EDGES SHALL FALL UPON 6", 12 GAUGE STUDS (6X1.625C) SPACED 24" O/C TYP (SEE PLAN). 2. HORIZONTAL JOINTS SHALL OCCUR OVER BLOCKING EQUAL IN SIZE TO THE STUDDING EXCEPT WHERE WAIVED BY THE INSTALLATION REQUIREMENTS FOR THE SPECIFIC SHEATHING MATERIAL SHOWN ABOVE. BRACED WALL PANEL SCHEDULE - STUDS @ 16" NOTES: BLOCKED?DESIGNATION ALL EXTERIOR UNLESS NOTED OTHERWISE OSB or PLYWOOD EXTERIOR ONLY (NOTE 2)7/16"YES SHTH. THICKNESSWALLRATED STRUC. SHEATHING TYPE EDGES HORIZONTAL MINIMUM CONNECTOR TYPE (OR EQUAL) 12"6" FIELD SPACINGEDGE SPACING (NOTE 2) 7/16"YES #8 SCREW (STEEL STUDS) 12"4" OSB or PLYWOOD EXTERIOR ONLY 0.12" NAIL X 15 8" MIN or #6 SCREWS GYPSUM BOARD BOTH SIDES 1/2" YES 7"7" INDICATES SIMPSON HOLD-DOWN STRAP. ATTACH PER DETAILS. 1 (NOTE 2) #8 SCREW (STEEL STUDS) ALL PARTITION WALLS DESIGN CRITERIA ALL CONSTRUCTION METHODS PER 2015 IBC RISK CATEGORY = I ELEVATION = 7650 LIVE FLOOR LOAD = 250 PSF SNOW GROUND SNOW LOAD = 67 PSF SNOW LOAD IMPORTANCE FACTOR = 0.80 SNOW EXPOSURE = 1.0 THERMAL FACTOR = 1.2 ROOF SNOW LOAD = 45.02 PSF WIND ULTIMATE WIND LOAD = 175 MPH (3 SECOND GUST, EXPOSURE C) WIND IMPORTANCE FACTOR = 1.0 ALTITUDE CORRECTION FACTOR = 0.80 SEISMIC MINIMUM SEISMIC DESIGN CATEGORY = B SEISMIC IMPORTANCE FACTOR = 1.0 SEISMIC COEFF (Fa*Ss) = 0.34 (2) 600S162-97 (50 KSI) JAMB STUD BOX HEADER SIMPSON STRONG-TIE® SHH6/54 EACH SIDE OF HEADER EACH W/ (16) #10-16 SCREWS TO JAMB & (16) #10-16 SCREWS TO HEADER LOCATED AS SHOWN (1) CRIPPEL STUD 800S200-97 (50 KSI) BOX HEADER TOP TRACK DESIGNED AS A HEADER BETWEEN ANCHORED STUDS #10 SCREW EACH FLANGE SIMPSON STRONG-TIE® RCKW 5.5 PER DETAIL @ 24" OC 600 S 162 97 (50KSI) STEEL STUDS @ 24" OC (6) #12-14 SCREWS TO STUD (1) 12" Ø WEDGE ANCHOR W/ 5" MIN. EMBED (2) 600S162-97 (50KSI) JAM STUBS 362S162-68 (50KSI) BOX HEADER SIMPSON STRONG-TIE® SHH3/68 EACH SIDE OF HEADER EACH W/ (6) #10-16 SCREWS TO JAMB & (6) #10-16 SCREWS TO HEADER LOCATED AS SHOWN (1) 4"X2"X12 GA. ANGLE X 5" LONG (50 KSI) W/ (6) #10-16 SCREWS @ EACH LEG W8X21 BEAM W/ TRACK TOP AND BOTTOM LOWER HEADER (1) TRACK MEMBER SECTION OF STUD ATTACHED W/ (4) #10 -16 SCREWS ATTACH FULL HEIGHT STUD TO CLOSURE TRACK W/ (2) #10-16 SCREWS @ 12" O.C. (2) FULL HEIGHT JAM STUDS (2) TRIMMER STUDS CLOSURE TRACK ATTACH TO TRIMMER STUD W/ (2) #10-16 SCREWS @12" O.C. FRAMING DETAILS CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 5954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459R Know what's below. Call before you dig. CALL 3-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 -FOOTINGS- DESIGN OF FOOTINGS IS BASED ON A MAXIMUM ALLOWABLE BEARING PRESSURE OF 3,500 PSF ON THE EXISTING SUBGRADE, BELOW FROST DEPTH BASED ON DEAD LOAD PLUS LIVE LOAD. ALL FOOTINGS TO BE SET ON EXISTING SUBGRADE. -ANCHOR BOLTS- ANCHOR BOLT DIAMETER AND LOCATION TO BE PER VARCO PRUDEN STEEL BUILDING PLANS, JOB #19-010322. CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATION OF ANCHOR PLATES AND BOLTS WITH DRAWINGS FROM VARCO PRUDEN. REINFORCED CONCRETE: DESIGN IS BASED ON "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE"(ACI 318-14). CONCRETE WORK SHALL CONFORM TO "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI 301). STRUCTURAL CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES: DETAILING, FABRICATIONS, AND PLACEMENT OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315-80). WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. REINFORCING BARS SHALL CONFORM TO ASTM A615, AND SHALL BE GRADE 60, EXCEPT TIES OR BARS SHOWN TO BE FIELD-BENT, WHICH SHALL BE GRADE 40. AT SPLICES, LAP BARS 50 DIAMETERS UNLESS NOTED OTHERWISE. AT CORNERS AND INTERSECTIONS, MAKE HORIZONTAL BARS CONTINUOUS OR PROVIDE MATCHING CORNER BARS. AROUND OPENINGS IN WALLS AND SLABS, PROVIDE 2-#5, EXTENDING 2'-0" BEYOND EDGE OF OPENING. IN CONTINUOUS MEMBERS, SPLICE TOP BARS AT MID-SPAN AND SPLICE BOTTOM BARS OVER SUPPORTS. PROVIDE INTERMITTENT SHEAR KEYS AT ALL CONSTRUCTION JOINTS AND ELSEWHERE AS SHOWN ON THE DRAWINGS. EXCEPT AS NOTED ON THE DRAWINGS, CONCRETE PROTECTION FOR REINFORCEMENT IN CAST-IN-PLACE CONCRETE SHALL BE AS FOLLOWS: A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH B. EXPOSED TO EARTH OR WEATHER: #5 BAR, W31 OR D31 WIRE, AND SMALLER C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND: SLABS, WALLS, JOISTS:#11 BAR AND SMALLER BEAMS, COLUMNS: PRIMARY REINFORCEMENT STIRRUPS, TIES, SPIRALS A REPRESENTATIVE OF THE ENGINEER SHOULD OBSERVE THE FOUNDATION EXCAVATION PRIOR TO FOUNDATION CONSTRUCTION. Intended Use f'c, psi 28day Ratio W/C Aggregate Maximum inches Slump Percent Entrained Air Type Cement Comments Admixtures, I/II2-4%63/4" Stone3,000Footings .5 3/4" StoneWalls 4,500 .45 6%4 I/II 3/4" StoneExt slab on grade 4,500 .45 6%4 I/II 3/4" StoneInt slab on grade 3,500 .5 2-4%4 I/II Fibermesh 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (IBC). THE ABOVE SHALL GOVERN EXCEPT WHERE THE CONSTRUCTION DOCUMENTS ARE MORE RESTRICTIVE. 2. ALL STRUCTURAL BACK FILL MUST BE COMPACTED TO 95% STANDARD PROCTOR. 3. CONTROL JOINTS ARE TO BE SAW CUT AND ARE RECOMMENDED @ 10' O.C. IN EACH DIRECTION AND HAVE A MINIMUM DEPTH OF 1". 4. ALL FOOTINGS AND PIERS TO BEAR ON EXISTING SUBGRADE. NOTES: 3" 1-1/2" 3/4" 1-1/2" 1-1/2" FOUNDATION DESIGN STATEMENT OF SPECIAL INSPECTIONS: SPECIAL INSPECTIONS ARE TO BE CONDUCTED ON THE FOUNDATION PIERS PER TABLE 1705.3 OF THE 2015 IBC. FLOOR SLABS AND FOUNDATION WALLS ARE EXCLUDED FROM THE SPECIAL INSPECTIONS PER IBC 1705.3. FREQUENCY OF CONCRETE STRENGTH TESTS (#6 OF TABLE 1705.3) IS TO BE ONE PER DAY. 1. INSULATION BELOW FLOOR SLAB WITH RADIANT HEAT TO BE R-15 FOR 48" FROM EXTERIOR WALL WITH INTERIOR AREA TO BE R-10. PER IECC C402.2.5 &6. RADIANT FLOOR SYSTEM BUILDING TYPICAL SECTION SCALE 1/4" = 1'-0" 8-FOOT GARAGE DOOR HEADER NOT TO SCALE 3-FOOT DOOR HEADER NOT TO SCALE NOT TO SCALE SIMPSON RCKW 5.5 FASTENER NOT TO SCALE SIMPSON RCKW 5.5 FASTENER INSTALLATION @ 24" O.C. ON CONCRETE 12-FOOT GARAGE DOOR HEADER NOT TO SCALE 54B E 54B F 54B G JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/20211 1 1 1 Michael Todd, P.E. 2021.12.1 4 16:37:46 -07'00' Reviewed by SAFEbuilt 01/06/2022 FF=7590.75 FF=7591.25 FF=7592.25 FF=7592.75 FF=7591.75 FF=7593.25 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12 ' X 1 4 ' ' GA R A G E D O O R 3068 DOOR T FIRE RISER ELECTRIC UNIT HEATER FF=7593.25 FF=7593.25 12'X14'' GARAGE DOOR 3068 DOOR12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 12'X14'' GARAGE DOOR 8'X10'' GARAGE DOOR T FIRE RISER ELECTRIC UNIT HEATER 4" CW 4" GV 4" BACKFLOW PREVENTER 4" PRV 4" METER 1" CW STUB 4" CW TO BUILDING 'A' 1" CW FIRE SUPPRESSION FIRE SUPPRESSION 4" FLOOR DRAIN 4" STUB (CAPPED) (TYP.) 1-1/2" VENT TO SEWER MAIN 1-1/2" VENT CLEANOUT 4" WASTE LINE FOUNDATION PLAN CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 6954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459R Know what's below. Call before you dig. CALL 3-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 BUILDING 'A' SCALE 1/8" = 1'-0" BUILDING 'B' SCALE 1/8" = 1'-0" DESCRIPTION MANUFACTURER MARLEY/BERKO MODEL UNIT HEAT SCHEDULE WATER ENTRY WHT500 ELECTRICAL DATA WATTS OR AMPS VOLTS/PH.ID UH-1 240V/1PH2.1 HEAT FUEL INPUT (MBH/KW) 0.5 KWELECT. OP. WT. (LBS.) 6.0 OPTIONS 1, 2 NOTES A NOTES: A. CEILING MOUNTED. OPTIONS (SOME FIELD INSTALLED): 1. UNIT DISCONNECT SWITCH 2. INTEGRAL HEATING THERMOSTAT JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/2021 Michael Todd, P.E. 2021.12.1 4 16:34:35 -07'00' Reviewed by SAFEbuilt 01/06/2022 X X X X X X X X X X X X X X X X X XX O H P O H P 80 . 0 10' UTILITY & DRAINAGE EASEMENT 10' UTILITY & DRAINAGE EASEMENT 15' BUILDING SETBACK 11'± 15.9'± ACACIA DRIVE OH P OH P OH P 7700 7 6 9 5 76 9 5 7 6 9 5 7690 769 0 76 9 0 7 6 8 5 76 8 5 S 86°00'00" E 200.00' S 0 4 ° 2 5 ' 1 0 " W 2 8 . 9 6 ' N 0 0 ° 4 7 ' 2 0 " W 1 4 4 . 0 6 ' N 0 0 ° 4 8 ' 3 8 " W 1 5 0 . 2 1 ' N 48 ° 5 9 ' 0 5 " E 1 5 6 . 6 7 ' 3 2 .2 6 ''''''''''''''''''''''''''''''''''''''''' C H =S 8 7 °5 2 '1 6 " EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE R =5 7 0 .0 0 ''''''''''''''''''''''''''''''''''''''''' L =3 2 .2 6 ''''''''''''''''''''''''''''''''''''''''' D =3 °1 4 '3 5 """"""""""""""""""""""""""""""""""""""""" 6 4.50''''''''''''''''''''''''''''''''''''''''' C H =S 2 9°26'48" WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW R =75.00''''''''''''''''''''''''''''''''''''''''' L =6 6.67''''''''''''''''''''''''''''''''''''''''' D =5 0°56'06""""""""""""""""""""""""""""""""""""""""" 4 3 .2 5'''''''''''''''''''''''''''''''''''''''''C H =S 8 0 °4 9 '59" EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE R =6 0 .00''''''''''''''''''''''''''''''''''''''''' L =4 4 .25''''''''''''''''''''''''''''''''''''''''' D =4 2 °15 '06""""""""""""""""""""""""""""""""""""""""" 103.46''''''''''''''''''''''''''''''''''''''''' C H = N 18°28'38" EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE R =60.00''''''''''''''''''''''''''''''''''''''''' L=124.74''''''''''''''''''''''''''''''''''''''''' D =119°07'17""""""""""""""""""""""""""""""""""""""""" LOT 5 MOUNTAIN TECHNOLOGICAL CENTER ZONED CH-COMMERCIAL HEAVY LOT 7 MOUNTAIN TECHNOLOGICAL CENTER ZONED CH-COMMERCIAL HEAVY LOT 4 ACACIA CORNER ZONED CH-COMMERCIAL HEAVY LOT 1 MOUNTAIN TECHNOLOGICAL CENTER ZONED CH-COMMERCIAL HEAVY 60' PUBLIC RIGHT-0F-WAY 50' PUBLIC RIGHT-0F-WAY 44' 20.00 20' ASPHALT SURFACE EXI S T I N G W O O D R A M P ASPHALT SURFACE 9 6 S S S S S S T 9 7 9 8 9 8 9 5 9 4 9 3 9 2 91 90 89 88 91 9092 93 93 92 92 91 95 96 9 4 9 5 97 23' 14.4'± BUILDING 'A' PROPOSED SELF STORAGE UNITS EXISTING ASPHALT ROADWAY MOUNTAIN VIEW COURT EXISTING 8" SEWER MAIN 19.50 (TYP.) 9.00 8.00 5.00 15' BUILDING SETBACK PROPOSED 5-FOOT SI D E W A L K W W W W W EX I S T I N G 6 " W A T E R L I N E 10' UTILITY & DRAINAGE EASEMENT 9 3 9 2 9 1 9 0 TOW 88.5 BOW 86 TOW 88.5 BOW 86 88 87 86 TOW 89 BOW 87 TOW 98.5 BOW 94.5 TOW 98.0 BOW 94.0 94 TOW 95.5 BOW 94.5 BUILDING 'B' PROPOSED SELF STORAGE UNITS 85 R Know what's below. Call before you dig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daho fescue Flanders poppy Blue flax Gaillardia Rocky Mtn. penstemon Black-eyed susan Blue grama Sandberg bluegrass Western wheatgrass Sheep fescue Slender wheatgrass 3Festuca idahoensis 27.20TOTAL Papaver rhoeas 0.1 Linum lewisii 0.5 Gaillardia aristata 1 Penstemon strictus 1.5 0.1Rudbeckia hirta Bouteloua gracilis v. Hachita 2 2Poa sandbergii Pascopyrum smithii v. Rosanna 7 Festuca ovina v. Covar 3 7Elymus trachycaulus v. Pryor PLS/ACRE POUNDSBOTANICAL NAMECOMMON NAME SEED MIX REQUIRED LANDSCAPING TREES SHRUBS TOTAL REQUIRED:21 63 21 63 THIS DETAIL IS TYPICAL IN INTENT ONLY. CONTRACTOR SHALL ADJUST HIS ? SQUARE, OPEN TO THE SKY, AND NOT COVERED BY ANY PAVING OR GRATING. NOTE: THIS DETAIL ASSUMES THAT THE PLANTING SPACE IS LARGER THAN 8 FT. TREE PLANTING DETAIL - B&B TREES IN ALL SOIL TYPES ? ??????A MINIMUM OF THREE YEARS AFTER WORK TO ACCOMMODATE ALL CONDITIONS. UNDISTURBED SUBGRADE PLANTING.?? ? ? ? ??? ? ?? ?? ??? ?? ?? ? ? ? ? ? ? ? ? ? ? ? ? ? DECIDUOUS TREES: WRAP TRUNK W/4" TREE WRAP FROM BOTTOM UP TO FIRST BRANCH & SECURE. STAKE & GUY USING 2 STAKES SPACED 180°. EXTEND TO THE EDGE OF THE CROWN. THE TERMINAL BUDS OF BRANCHES THAT MAY BE PRUNED; HOWEVER, DO NOT REMOVE SOME INTERIOR TWIGS AND LATERAL BRANCHES LEADERS, AND BROKEN OR DEAD BRANCHES. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT DO NOT HEAVILY PRUNE THE TREE AT PLANTING. TO FACE NORTH AT THE SITE WHEN EVER IN THE NURSERY, AND ROTATE TREE MARK THE NORTH SIDE OF THE TREE HIGHER IN SLOWLY DRAINING SOILS. SET TOP OF ROOT BALL FLUSH TO MAINTAIN THE MULCH WEED-FREE FOR MULCH IN CONTACT WITH TREE TRUNK. 3 IN. MULCH. DO NO PLACE GRADE OR 1-2 IN. POSSIBLE. ? 5 FT. DIAM. MIN. 8 IN. ? ? ? MULCH RING ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?? ?? ? ? ? ? ? ? ? ? ? ? ? ? ???? ? ? ? ? ?? ? ? ??? ?? ? REMOVE ALL TWINE , ROPE AND BURLAP FROM TOP HALF OF ROOT BALL THE ROOT BALL, CUT THE WIRE BASKET AND REMOVE. IF PLANT IS SHIPPED WITH A WIRE BASKET AROUND ? SO THAT ROOT BALL DOES NOT SHIFT. BASE FIRMLY WITH FOOT PRESSURE TAMP SOIL AROUND ROOT BALL OR TAMPED SOIL. PLACE ROOT BALL ON UNEXCAVATED ? ? ? ?? ?? ? ? ?? ? ? ? ? ? ? ?? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ??? ?? EVERGREEN TREES: STAKE & GUY USING 3 STAKES @ 120° AROUND TREES. NO SPRAYING OR WRAPPING MAINTAIN UNDER ALL TOPO CONDITIONS APPROVED STAKE MATERIAL HARDWOOD STAKES OR OTHER 1.5 x 1.5 IN. TWIST WIRE TO TIGHTEN. GALVANIZED WIRE OR CABLE PLASTIC HOSE 0.5 IN. DIAM. DO NOT COVER THE TOP OF THE ROOT FLARE IS NOT VISIBLE SHALL BE REJECTED. OF THE ROOT BALL. TREES WHERE THE TRUNK THE TRUNK FLARE IS VISIBLE AT THE TOP EACH TREE MUST BE PLANTED SUCH THAT BEYOND EDGE OF ROOT BALL. 4 IN. HIGH EARTH SAUCER 4 ft. ? ? ?? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?? ?? ? ? ? ? ? ? ? ? ? ? ? ? 6 ft. BALL WITH SOIL. NOTE: PROTECT TREE WITH 5' TALL WIRE FENCING 1'-6" ABOVE GROUND. FENCE TO REMAIN UNTIL PLANT CAN SURVIVE WILDLIFE DAMAGE. EXCAVATE TREE PIT TO 2X BALL DIAMETER. LANDSCAPE PLAN CUSTOM CONTRACTING, INC. SHEET TITLE: BY:REVISION:DATE: CLIENT: SHEET 7 SHEET 7954.002 JOB NO.MST DATE SCALE APPROVED BY AS SHOWN MAY 2021 JLR JLR MST DRAWN BY CHECKED BY DESIGNED BY PROJECT TITLE: 2021 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459 MAX STORAGE LANDSCAPE PLAN 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 MAX STORAGE 1748 MOUNTAIN VIEW CT. ESTES PARK, CO 80517 ESTES VALLEY DEVELOPMENT CODE §7.5.E-1: REQUIRES ONE TREE AND THREE SHRUBS TO BE PLNATED PER 1000 SF OF LOT COVERAGE EXCLUDING PARKING LOTS. (20,800 SF COVERAGE) ESTES VALLEY DEVELOPMENT CODE §7.5.F.2.b.(2)(c): STREET BUFFER NOT REQUIRED FOR CH-COMMERCIAL HEAVY ZONED PROPERTY ESTES VALLEY DEVELOPMENT CODE §7.5.G.2.a: PARKING LANDSCAPING NOT REQUIRED FOR CH-COMMERCIAL HEAVY ZONED PROPERTY SCALE 1"=20' JLRBUILDING REVIEW MEMO DATED 12/06/202112/13/2021 Michael Todd, P.E. 2021.12.1 4 16:33:19 -07'00' Reviewed by SAFEbuilt 01/06/2022