Loading...
HomeMy WebLinkAboutPLANS Deck 690 Moraine Ave #7 2021-07-132x8 PRESSURE TREATED YELLOW PINE LEDGER W/ (2) 3-5/8" LEDGER LOKS AT 12" OC INTO RIM JOIST. LEDGER TO BE FLASHED TO PREVENT WATER FROM CONTACTING THE HOUSE BAND JOIST 12' 9' A' A 2x8 @ 16" OC PRESSURE TREATED YELLOW PINE 690 MORAINE AVE. # 7 ESTES PARK, CO 80517 6"X10" #1 DF OR 3-1 8" X 9" EXTERIOR GRADE GLULAM 12"Ø CAISSON INSTALL SIMPSON DTT1Z TENSION TIES AT 4' OC (4 TOTAL) 690 MORAINE DRIVE ESTES PARK, CO 80517 M O U N T A I N R I V E R T O W N H O M E S MOUNTAIN HAVEN CONDOMINIUMS UNIT 7, LCE M O U N T A I N H A V E N C O N D O M I N I U M S G C E PROPOSED 9'X12' DECK 40' +/- UNIT # 7 RESIDENCE LCE UNIT # 7 GARAGE GROUND SNOW LOAD = 70 PSF - (10 PSF/1000 FT) * (8000-7605 FT) = 66.0 PSF (INTERPOLATED USING ELEV = 7605 FT) ULTIMATE WIND LOAD = 173 MPH DECK LIVE FLOOR LOAD = 40 PSF DECK SNOW LOAD = INTERPOLATED GROUND SNOW LOAD ELEVATION = 7605 FT, 66.0 PSF SOIL BEARING CAPACITY = 3,500 PSF DECOMPOSED AND FRACTURED GRANITE BEDROCK ALL CONSTRUCTION TO CONFORM TO TOWN OF ESTES PARK STANDARDS AND CURRENT INTERNATIONAL RESIDENTIAL CODE AND ALL OTHER APPLICABLE CODES. DESIGN LOAD CRITERIA: TOP CAP 36 " M I N . 0'-4" O.C. MAXIMUM 6x6 TIMBER POST @ 6' O.C. MAX SPACING (TYP) 1X COMPOSITE OR 2X6 WOOD DECKING BALUSTERS 4" O.C. MAX SPACING (TYP) TOP RAIL 3/4" CHAMFER 1/2" THRU BOLTS DECK RAILING FRONT VIEW SCALE 1/2"=1' 6X10 #1 DF OR 3- 1 8" X 9" EXTERIOR GRADE GLULAM 6x6 POST DF (TYP) 12" Ø CAISSON (2) 1/2" THRU BOLTS (TYP) 2X8 PT JOIST @ 12" OC 1X COMPOSITE OR 2X6 TIMBER DECKING DECK PIER DETAIL SCALE 1/2" = 1' 2X6 TOP RAIL BALUSTERS 4" O.C. MAX SPACING (TYP)36 " M I N . A SIMPSON LUS HANGER EACH END SECTION A-A' SIMPSON PB66 POST BASE 6X10 #1 DF OR 3- 1 8"X9" EXTERIOR GRADE GLULAM 36 " M I N . 6" (3) #4 REBAR 4" 1- ALL DECK JOISTS TO BE PRESSURE TREATED YELLOW PINE @ 12" O.C. UNLESS. 2- ATTACH RIM JOIST TO EXISTING BUILDING WITH 2 ROWS 3-5/8" LEDGER LOK @ 12" OC. 3- LEDGER TO BE FLASHED TO PREVENT WATER FROM CONTACTING THE HOUSE BAND JOIST 4- INSTALL SIMPSON DTT1Z DECK TIES @ 4' OC (4 TOTAL) 5- ALL STRUCTURAL BACKFILL MUST BE COMPACTED TO 95% STANDARDPROCTOR. 6- ALL CONCRETE DESIGN IS BASED UPON "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14). 7-CONCRETE SPECIFICATIONS: Fc = 3,500 psi @ 28 DAYS WITH 6% AIR (Ø 1.5%) 8- WOOD POST JOIST AND BEAMS SUPPORTING THE DECK SHALL BE NATURALLY DURABLE OR PRESSURES TREATED AS DEMONSTRATED FOR THIS GEOGRAPHICAL AREA. 9- ALL PIERS TO BE 12" Ø UNLESS SPECIFIED OTHERWISE. NOTES: SHEET TITLE: 1 CLIENT: SHEET PROJECT TITLE: 1966-001 JOB NO. SHEET DATE: SCALE: 05/21/2021 AS SHOWN APPROVED BY:MST REVISION:BY: CHECKED BY: DRAWN BY: DESIGNED BY: DATE: MST MST MST JIM & GAIL SHROYER 2018 CORNERSTONE ENGINEERING & SURVEYING, INC. COPYRIGHT - ALL RIGHTS RESERVED 1692 BIG THOMPSON AVE. SUITE 200 ESTES PARK, CO 80517 PH: (970) 586-2458 FAX: (970) 586-2459 SCALE 1/4"=1'-0" DECK REPLACEMENT PLAN UNIT 7, MOUNTAIN HAVEN CONDOMINIUMS PARCEL # 3526-45-0007 LEGAL DESCRIPTION VICINITY MAP SCALE 1"=700' N SITE PLAN SCALE 1"=40' 690 MORAINE AVE, # 7 ESTES PARK, CO 80517 DECK ADDITION NOTE: THIS DRAWING DOES NOT REPRESENT A MONUMENTED BOUNDARY SURVEY, BOUNDARY INFORMATION WAS ACQUIRED FROM FINAL MAP OF MOUNTAIN HAVEN CONDOMINIUMS PREPARED BY VAN HORN ENGINEERING AND DATED 2-21-03. 1 1 1 1 1 1 MSTREVIEW COMMENTS 06/09/202106/10/2021 1 1 11 1 Michael Todd, P.E. 2021.06.1 0 17:29:49 -06'00'