HomeMy WebLinkAboutLETTER Structural Framing 2774 Ypsilon Circle 2022-04-22 2 5 3 5 1 7 T H S T R E E T , S U I T E A , D E N V E R , C O 8 0 2 1 1  3 0 3 - 7 8 3 - 4 7 9 7  3 0 3 - 8 3 0 - 9 1 3 3 F A X  Structural Wood Framing Observation TO: Kinley Built DATE: 03/11/2022 Revised: 4/20/2022 2774 Ypsilon Circle INSP. DATE: 03/08/2022 Estes Park, CO 80517 WEATHER: Sunny 20 deg PROJECT: Wieber Residence ADDRESS: 2774 Ypsilon Circle ATTN: Nathan Kinley LOCATION: Estes Park, CO 80517 Wall Framing Observed: Floor Framing Observed: Roof Framing Observed: Stud Wall Framing Floor Framing Roof Framing Stud Wall Sheathing Timber Frame (by others) Floor Sheathing Timber Frame (by others) Roof Sheathing (SIPS panels – by others) Wall Items Checked: Floor Items Checked: Roof Items Checked: Stud Grade/ Size/Spacing Floor Joist Grade/Size/Spacing Roof Framing Grade/Size/Spacing Wall Sheathing Grade/Size Floor Sheathing Roof Sheathing Wall Sheathing Nail Spacing Floor Sheathing Nail Spacing Roof Sheathing Nail Spacing Anchor Bolt Size/Spacing Steel Framing Other Hold downs/Strap Ties Steel Columns Other Framing appears to be installed in conformance with approved drawings and standard construction practice with exception to the deficiencies noted below. Remarks or Deficiencies Noted: - Several double-sided shear wall locations were located directly adjacent to the interior timber frames and could not have the interior sheathing/nailing installed. Please see revised structural plans dated 4/4/2022 for updated shear wall types. - (4) 2x6 posts were installed at grids 5 and G and at grids 5 and B in lieu of the 3” steel pipe columns called out on the structural plans. - The W10x45 floor beam along grid G was installed as a continuous span connecting to the wood beams at gridline 5. This revised span condition has been verified and no further action is required. - Sole plate nailing of shearwalls to foundation sill plate not installed per the shearwall schedule. Per communication with the contractor, this nailing is not required as the exterior sheathing extends to the foundation sill plate without a sheathing splice and shearwall boundary nailing was provided to the foundation sill plate. All items indicated above have been communicated to the contractor prior to leaving the site. Supplemental structural drawings will be provided to the contractor for the required repairs/revisions. Photos showing the repaired condition need to be sent to our office once the repairs are completed. Scott Jackson Ysidoro Gutierrez P.E. Design Engineer Associate Principal 04/20/2022