HomeMy WebLinkAboutPLANS Residential Addition 531 Highland Ln 2020-05-08APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
05/08/2020
This structure must comply
with the requirements of the
2017 National Electrical Code
General Notes:
-Min (1) emergency escape
and rescue opening req’d
per bedroom
-Glazing to be tempered per
R308
-Min (1) programmable
thermostat req’d
-Smoke alarm req’d in each
sleeping room
-Smoke/CO alarm req’d w/in
15’ vicinity of bedroom
exterior.
-Fireblock/Draftstop all
chases and penetrations
General Notes All Elevations:
-Asphalt shingles to meet 175 MPH wind-speed
-All stone, stucco and siding to have barrier
underneath at exterior walls
-Roof slopes from 2:12 UP to 4:12 req double
underlayment
-Sills less than 24” w/72+” of fall req fall protection
-Roof ventilation per R806
-All stairs, landings, guards, rails and walking
surfaces to comply with R311 and R312
Reviewed by
SAFEbuilt
05/08/2020
Reviewed by
SAFEbuilt
05/08/2020
General Residential Electrical Requirements
- Smoke detectors required inside and outside all
bedrooms.
- Min. one smoke detector required on each level.
- Carbon monoxide detectors required within 15' of
all bedrooms throughout home.
- All outlets less than 5'6" AFF to be tamper
resistant.
- All circuits arc-fault except bathrooms and
unfinished areas.
- Min. (2) 20A, dedicated, GFCI/AFCI protected,
small appliance, countertop circuits required in
kitchens.
- Min. (1) 20A, dedicated, GFCI protected outlet
required within 36" of all lavs.
- Garage circuits to be dedicated, 20A, and GFCI
protected.
- Laundry circuit to be 20A, GFCI protected.
- All GFCI devices must be readily accessible.
- Crawlspace lighting circuits to be GFCI protected.
- Service receptacles required within 25' of all
appliances.
Reviewed by
SAFEbuilt
05/08/2020