Loading...
HomeMy WebLinkAboutPLANS Remodel 184 E Elkhorn Ave 2020-03-19Reviewed by SAFEbuilt 02/19/2020 WH WH VICINITY MAP OWNER:IJ ESTES PARK LLC 1769 ROCKY MOUNTAIN AVE LOVELAND, CO 80538 TEL: FAX: E-MAIL: CONTACT: RANDELL JOHNSON @ INFUSION ARCHITECTS, LLC 206 EAST 4TH STREET, SUITE 250 LOVELAND, CO 80537 TEL: 970-775-2925 E-MAIL: CHAD.ARTHUR@INFUSIONARCHITECTS.COM CONTACT: CHAD ARTHUR MECHANICAL/ PLUMBING DESIGN: G2 CONSULTING ENGINEERS 1029 MAIN STREET WINDSOR, CO 80550 TEL: 970.460.7400 E-MAIL: DSMITH@G2CE.COM CONTACT: DAVE SMITH PROJECT TEAM ABBREVIATIONS INTERIOR ELEVATION DETAIL SECTION DOOR NUMBER WINDOW NUMBER WALL TYPE COLUMN GRID REVISION ROOM NAME & NUMBER LEVEL 1 24 3 I2.11 VIEW TITLE STUD SIZE FINISH MATERIAL GRAPHIC SYMBOLS A2.11 BUILDING ELEVATION EQUIPMENT TAG A1.01 1 SIM Room 101 A A 1 101A 1 Title 1/8" = 1'-0"A1.01 P3 AS 1 P-1 TS-1 CPT-1 RB-1 FLOORING WALL FINISHES TRANSITION STRIP INTERIOR ELEVATION KEYNOTE06 01 1 ELECTRICAL DESIGN: NORTH ARCHITECT OF RECORD NAME ADDRESS CITY, STATE ZIP TEL: FAX: E-MAIL: CONTACT: GENERAL CONTRACTOR: DRAWING INDEX INTAJUICE ESTES PARK, COLORADO 1 DEMOLITION TAG PROJECT DESCRIPTION 815 SF TENANT FINISH WITHIN AN EXISTING BUILDING IN ESTES PARK, COLORADO. TENANT FINISH TO INCLUDE FRONT OF HOUSE AND BACK OF HOUSE KITCHEN FOR SMOOTHIE PREP AS WELL AS A FRONT CUSTOMER TAKE OUT AREA. 1 A101 SIM PROJECT LOCATION G2 CONSULTING ENGINEERS 1029 MAIN STREET WINDSOR, CO 80550 TEL: 970.460.7400 E-MAIL: DSMITH@G2CE.COM CONTACT: DAVE SMITH E A S T E L K H O R N A V E . WEST ELKHORN AVE. MO R A I N E A V E . BIG H O R N D R I V E W E I S T D R I V E CLEAVE STREET CODE STUDY 95A-2 519 1 WAITING LINE 365A-2 2001.8 1 FOOD PREP AREA OL = REQUIRED: PROVIDED: AT DOOR 32.0" 32.9" 26.2 TRAVEL DISTANCE = 63' - 0" FE 38A-2 152.6 1 DINING 131M 602.2 1 RETAIL 171S-2 3000.6 1 STORAGE NOT IN SCOPE NOT IN SCOPE 3'- 2 " 5'-2" 5'-4" 3'- 2 " TRASH ENCLOSURE STAIR ACCES TO BASEMENT TOILET TOILET SUBWAY CUSTOMER AREA SUBWAY CUSTOMER AREA SUBWAY B.O.H. SUBWAY F.O.H.NOT IN SCOPE NOTE: INTAJUICE EMPLOYEES WILL USE SUBWAY RESTROOMS. INTAJUICE AND SUBWAY ARE OWNED AND OPERATED BY THE SAME BUSINESS OWNER. TO RESTROOMS EMPLOYEE PATH 1 OCCUPANCY GROUP NUMBER OF OCCUPANTS OCCUPANT LOAD FACTOR NOMINAL SQ. FT. NUMBER OF EXITS REQUIRED OCCUPANT LOAD APPLICABLE CODES PROJECT DESCRIPTION: 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL EXISTING BUILDING CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE OCCUPANCY CLASSIFICATION: EXISTING BUILDING OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: EXISTING BUILDING SEE CODE PLAN FOR OCCUPANT LOADS AND EXITING WIDTHS. LEGEND FE FIRE EXTINGUISHER B V-B, 1 HOUR FIRE BARRIER EXIT ACCESS TRAVEL DISTANCE 13085E 2042 2 AREA NON-SPRINKLED 815 SF TENANT FINISH WITHIN AN EXISTING BUILDING IN ESTES PARK, COLORADO. TENANT FINISH TO INCLUDE FRONT OF HOUSE AND BACK OF HOUSE KITCHEN FOR SMOOTHIE PREP AS WELL AS A FRONT CUSTOMER TAKE OUT AREA. 26 TOTAL OCCUPANTS IBC SECTION 303.1.1, EXCEPTION 1: A BUILDING OR TENANT SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY. 1-HR RATED WALL ASSEMBLY 1 NOTES FOR GENERAL CONTRACTOR: 1. EXISTING EXIT DOOR TO PROVIDE FREE EGRESS AT ALL TIMES. LOCKING HARDWARE IS PERMITTED, PROVIDED THE HARDWARE AND SIGNAGE COMPLIES WITH IBC SEC 1010.1.9.3 "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" 2. TACTILE EXIT SIGNAGE REQUIRED PER IBC SEC 1013.4 3. HEADROOM AND PROJECTIONS MUST COMPLY WITH IBC SEC 1003.2 & 1003.3 4. PROVIDE THE 1-HR WALL ASSEMBLY CUTSHEETS ON SITE FOR CONSTRUCTION AND INSPECTION 1 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:18:53 AM A0.0 CO V E R S H E E T IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS A0.7 Unnamed ARCHITECTURAL A0.0 COVER SHEET A0.2 GENERAL NOTES A1.0 DEMOLITION PLAN A1.1 FIRST FLOOR PLAN A2.1 ROOF PLAN A3.1 FIRST FLOOR REFLECTED CEILING PLAN A8.2 FIRST FLOOR FINISH PLAN A8.4 INTERIOR FINISH ELEVATIONS A9.1 EQUIPMENT PLAN MECHANICAL M0.1 MECHANICAL INDEX, LEGEND AND NOTES M0.2 MECHANICAL SCHEDULES AND DIAGRAMS M0.3 MECHANICAL SPECIFICATIONS M1.1 FLOOR PLAN - MECHANICAL M2.1 ROOF PLAN - MECHANICAL PLUMBING P0.1 PLUMBING INDEX, LEGEND AND NOTES P0.2 PLUMBING SCHEDULES P0.3 PLUMBING DIAGRAMS P1.1 FLOOR PLAN - PLUMBING ELECTRICAL E0.0 ELECTRICAL LEGENDS & GENERAL NOTES E0.1 ELECTRICAL SPECIFICATIONS E0.2 ELECTRICAL ONE-LINE E0.3 COMCHECK ED1.0 FIRST FLOOR DEMOLITION PLAN E1.0 OVERALL PLAN E1.1 FIRST FLOOR POWER PLAN E1.2 FIRST FLOOR PLAN - KITCHEN EQUIPMENT E2.1 FIRST FLOOR LIGHTING PLAN E2.2 ROOF PLAN REQ REQUIRED RESIL RESILIENT RR RESTROOM REV REVISIONS, REVISED ROW RIGHT OF WAY RD ROOF DRAIN RTU ROOF TOP UNIT RV ROOF VENT RFG ROOFING RM ROOM RO ROUGH OPENING RB RUBBER BASE SAN SANITARY SMH SANITARY MANHOLE SCHED SCHEDULE SECT SECTION SERV SERVICE SHT SHEET SIM SIMILAR SC SOLID CORE SS SOLID SURFACE S SOUTH SPEC SPECIFICATIONS SOV SPRAY ON VINYL SQ SQARE SF SQUARE FEET SSTL STAINLESS STEEL STD STANDARD STL STEEL STOR STORAGE SD STORM DRAIN STRUCT STRUCTURAL SUSP SUSPENDED S.A.T. SUSPENDED ACOUSTICAL TILE SYM SYMMETRICAL SYST SYSTEM TEL TELEPHONE TV TELEVISION TEMP TEMPERATURE, PEMPERED (T) TEMPERED GLAZING THK THICK THRES THRESHOLD TP TOILET PARTITION T&G TONGUE AND GROOVE T.O. TOP OF TRANS TRANSFORMER TS TRANSISTION STRIP TR TREAD TYP TYPICAL UV ULTRA VIOLET UG UNDERGROUND UNFIN UNFINISHED UH UNIT HEATER UNO UNLESS NOTED OTHERWISE VENT VENTILATOR VIF VERIFY IN FIELD VERT VERTICAL VCT VINYL COMPOSITION TILE VWC VINYL WALL COVERING WC MATER CLOSET WSCT WAINSCOT WH WATER HEATER WR WATER RESISTANT WV WATER VALVE WP WATERPROOF WT WEIGHT WWF WELDED WIRE FABRIC W WEST W/ WITH W/O WITHOUT WD WOOD WPT WORK POINT YD YARD ZVB ZONE VALUE BOX LAM LAMINATED LAV LAVATORY LCC LEAD COATED COPPER LH LEFT HAND LT(G) LIGHT (ING) LP LIGHTING PANEL LTWT LIGHTWEIGHT LF LINEAR FEET LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LB(S) POUND(S) MDP MAIN DISTRIBUTION PANEL MH MANHOLE MFR MANUFACTURER MAS MASONRY MO MASONRY OPENING MAX MAXIMUM MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MTL METAL MIN MINIMUM MISC MISCELLANEOUS MTD MOUNTED NOM NOMINAL N NORTH NIC NOT IN CONTRACT NTS NOT TO SCHALE NO. NUMBER OC ON CENTER(S) OI OPEN ITEM OPG OPENING OPP OPPOSITE OZ OUNCE OD OUTSIDE DIAMETER ORD OVERFLOR ROOF DRAIN P PAINT PTD PAINTED PR PAIR PNL PANEL PRTN PARTITION PAT PATTERN PVMT PAVEMENT PERF PERFORATED PLAS PLASTER PLAM PLASTIC LAMINATE PL PLATE PLBG PLUMBING PV PLUMBING VENT PLYWD PLYWOOD PT POINT POL POLISH(ED) PVC POLYVINELY CHLORIDE PCF POUNDS PER CUBIC FOOT PLF POUNDS PER LINEAR ROOT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PP POWER PANEL PROJ PROJECT PA PROJECT ARCHITECT QTY QUANTITY QT QUARRY TILE RH IRGHT HAND R RADIUS RWL RAIN WATER LEADER RECPT RECEPTACLE RE REFER REF REFERENCE RCP REFLECTED CEILING PLAN REINF REINFORCE (D) (ING) EA EACH E EAST EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER ELEC ELECTRICAL EP ELECTRICAL PANEL MONOMER EL ELEVATION EMERG EMERGENCY ENCL ENCLOSURE ENGR ENGINEER EF EPOXY FLOORING EQ EQUAL EQUIP EQUIPMENT EPDM ETHYLENE PROPYLENE DIENE MONOMER EXH EXHAUST EXIST EXISTING EXP EXPANSION EJ EXPANSION JOINT EXT EXTERIOR EIF EXTERIOR INSULATION FINISH SYSTEM FWC FABRIC WALL COVERING FO FACE OF FRP FIBER REINFORCED PANEL FIN FINISH(ED) FF FINISHED FLOOR FG FINISHED GRADE FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FHC FIRE HOSE CABINET FP FIREPROOF FIXT FIXTURE FLASH FLASHING FD FLOOR DRAIN FS FLOOR SINK FLR(G) FLOOR(ING) FL FLOW LINE FLUOR FLUORESCENT FT FOOT, FEET FTG FOOTING FDN FOUNDATION FURN FURNISH(ED) FRR FURRING GALV GALVANIZED GA GAUGE, GAGE GC GENERAL CONTRACTOR GFI GROUND FAULT INTERRUPTER GYP GYPSUM HDWR HARDWARE HDWD HARDWOOD HVAC HEAT, VENT, A/C HGT HEIGHT HID HIGH INTENSITY DISCHARGE HC HOLLOW CORE HM HOLLOW METAL HORIZ HORIZONTAL HB HOSE BIBB HW HOT WATER INCAND INCANDESCENT IN INCH INCL INCLUDE (D) (ING) ID INSIDE DIAMETER INSUL INSULAT(ED)(ION) INT INTERIOR INV INVERT JT JOINT JB JUNCTION BOX K KIP (1,000 POUNDS) K-FT KIP FEET & AND @ AT ℄ CENTERLINE # POND, NUMBER AFF ABOVE FINISHED FLOOR ACOUS ACOUSTIC / ACOUSTICAL ACT ACOUSTICAL CEILING TILE ADDN ADDITION ADJ ADJACENT A/C AIR CONDITIONING AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANCH ANCHOR ANG ANGLE ANOD ANODIZED APPROX APPROXIMATE ARCH ARCHITECT ASSOC ASSOCIATED B&B BALLED AND BURLAPPED BSMT BASEMENT BM BEAM BRG BEARING B.M. BENCH MARK BIT BITUMINOUS BLK'G BLOCK(ING) BD BOARD BOT BOTTOM B.O. BOTTOM OF BRK BRICK BLDG BUILDING BL BUILDING LINE BUR BUILT-UP ROOFING CAB CABINET CUH CABINET UNIT HEATER CPT CARPET CI CAST IRON CB CATCH BASIN CLG CEILING CD CEILING DIFFUSER CR CEILING REGISTER CEM CEMENT CTR CENTER CT CERAMIC TILE CO CLEAN OUT CLR CLEAR CW COLD WATER COL COLUMN CONC CONCRETE CMU CONCRETE MASONRY UNIT CU CONDENSING UNIT CONN CONNCECTION CONST CONSTRUCTION CONTR CONTRACT(OR) CJ CONTROL JOINT CG CORNER GUARD CFM CUBIC FEET PER MINUTE CUSP CUSPIDOR CONT OCNTINUOUS DL DEAD LOAD DET DETAIL DIA DIAMETER DIM DIMENSION DISP DISPENSER DP DISTRIBUTION PANEL DR DOOR DBL DOUBLE DN DOWN DS DOWNSPOUT DMH DRAINAGE MANHOLE DWG DRAWING DF DRINKING FOUNTAIN 1/8" = 1'-0" FIRST FLOOR CODE PLAN 12" = 1'-0" CODE - 2015 COMMERCIAL NOTES Revision Number Revision Date 1 2/18/2020 APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:18:55 AM A0.2 GE N E R A L N O T E S IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS Revision Number Revision Date Reviewed by SAFEbuilt 02/19/2020 UP UP UP WH 2 1 5 5 2 5 5 11 3 3 5 4'-9" 1'-0" 3 3 5 5 5 6 7 NOT IN SCOPE NOT IN SCOPE 9 1 4 5 5 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:18:56 AM A1.0 DE M O L I T I O N P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS DEMOLITION LEGEND NO.DESCRIPTION 1 REMOVE WALL 2 REMOVE DOOR 3 REMOVE WOOD TRIM, PATCH AND REPAIR GYP. BEHIND 4 REMOVE CEILING 5 REMOVE T&G CLADDING 6 PATCH AND REPAIR GYP. BOARD OF EXISTING WATER DAMAGE @ SINK 7 REMOVE EXISTING FLOORING & BASE 9 REMOVE EXISTING WATER CLOSET 3/8" = 1'-0"A1.0 1 DEMO PLAN 3/16" = 1'-0"A1.0 2 DEMO RCP Revision Number Revision Date 1 2/18/2020 1 Reviewed by SAFEbuilt 02/19/2020 UPWH UP WH ALIG N ALIGN INTERIOR WALLS SYSTEM NOTES INTERIOR PARTITION SUFFIXES A -STANDARD WALL, 1x LAYER 5/8" GYP. BD. ON EACH SIDE OF STUD FRAMING. TERMINATE FRAMING ABOVE HIGHEST ADJACENT FINISHED CEILING. LATERALLY BRACE FRAMING AT 4-'0" MIN. O.C. AND AT ENDS. PROVIDE SOUND BATT INSULATION FULL HEIGHT. B -1-SIDE FINISHED, 1x LAYER 5/8" GYP. BD. ON ONE SIDE OF STUD FRAMING ONLY. TERMINATE FRAMING ABOVE HIGHEST ADJACENT FINISHED CEILING. LATERALLY BRACE FRAMING AT 4-'0" MIN. O.C. AND AT ENDS. D -DEMISING WALL, 1x LAYER 5/8" GYP. BD. EACH SIDE OF STUD FRAMING. TERMINATE GYP. BD. ON ONE SIDE 2" ABOVE HIGHEST ADJACENT FINISHED CEILING. EXTEND FRAMING FULL HEIGHT AND ATTACH TO DECK ABOVE W/ SLIP TRACK. EXTEND GYP. BD. ON OTHER SIDE TO BOTTOM OF DECK. PROVIDE SOUND BATT INSULATION FULL HEIGHT TO DECK. F1 -1 -HR RATED WALL, 1X LAYER 5/8" TYPE 'X' GYP. BD. ON EACH SIDE OF THE STUD FRAMING, STUD FRAMING SHALL EXTEND FULL HEIGHT TO UNDERSIDE OF DECK/STRUCTURE, SEAL W/ FIRE-RATED SEALANT. M -MOISTURE WALL, APPLY FIBER REINFORCED PANELS (FRP) FROM FLOOR TO 4'-0" A.F.F. OVER 5/8" MOISTURE RESISTANCE GYP. BD. 1 -ALL WALLS ARE P4-A UNLESS NOTED OTHERWISE. 2 -ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUD FRAMING OR NOMINAL FACE OF MASONRY WALLS UNLESS NOTED OTHERWISE. 3 -PROVIDE GYP. BOARD CONTROL JOINTS AT WALLS OVER 25'-0" IN LENGTH 4 -FRAME DOOR OPENINGS 5" FROM FACE OF PERPENDICULAR WALL ON HINGE SIDE AND 1'-7" FROM FACE OF PERP. WALL ON LATCH SIDE UNLESS NOTED OTHERWISE. 5 -ALL ANGLED WALLS ARE A MULTIPLE OF 45° U.N.O. 6 -PROVIDE WOOD BLOCK OR METAL STRAP BACKING IN PARTITIONS AS NEEDED TO PROVIDE FOR WALL MOUNTED EQUIPMENT, CABINETS, ACCESSORIES, ETC. IT SHALL BE THE RESPONSIBILITY OF THE GC TO COORDINATE THE REQUIRED LOCATIONS FOR BACKING. INTERIOR NOTES P2 -2 1/2" WOOD STUD FRAMING AT 16" O.C. P3 -3 5/8" WOOD STUD FRAMING AT 16" O.C. P4 -2X4 WOOD STUD FRAMING AT 16" O.C. P6 -6" WOOD STUD FRAMING AT 16" O.C. LEGEND BULKHEAD P6 D B.O.H. 103 F.O.H. PREP 102 CUSTOMER 101 TRASH ENCLOSURE 103 NOTE: USE 1/2" PLYWOOD SHEATHING (IN LIEU OF 5/8" GYP BD) BEHIND FRP IN BACK AREA REMOVABLE CHAIN FOR LINE MANAGEMENT 105 E104 COMMON AREA P3 L P3 L 2'-7" 8'-1 1/2"5'-4 1/2" CLEAR 10'-7" 7'- 3 1 / 2 " 4'- 7 1 / 2 " 2'- 4 " 3'- 6 " 2'- 8 1 / 2 " 5'-11 1/2" KNOXBOX LOCK BOX INFILL OPENING WITH 1-HOUR WALL ASSEMBLY 26'-10 1/2" P6 F1 42" H. RECESSED ELEC PANEL 36" MIN CLEAR 3'- 2 " 36" MIN CLEAR 3'- 2 " 60" MIN CLEAR 5'-2" 5'-1" 60" MIN CLEAR 5'-4" STAINLESS STEEL GUIDE RAILS, MOUNTED TO FLOOR STRUCTURE BELOW 1/2" PLYWD GOES OVER 5/8" TYPE 'X' GYP BD AT DEMISING WALL 1 COMMON HALL STAIR ACCESS TO 2ND FLOOR STAIR ACCES TO BASEMENT NOT IN SCOPENOT IN SCOPE NOT IN SCOPE SUBWAY CUSTOMER AREA SUBWAY B.O.H. 5'- 2 " 4'- 2 " IN F I L L F R A M E FL O O R O P E N I N G PROVIDE 30X48 FLOOR HATCH FOR BASEMENT ACCESS 1 FLOOR LINE PE R S C H E D U L E DO O R H E I G H T PER SCHED WIDTH TYPE 'F' FLUSH PANEL SET 1B 2 HINGE ENTRY 1 SPRING HINGE 1 ENTRANCE LOCK SET 1 SILENCERS SET 2A 3 HINGE PASSAGE 1 SCHLAGE KEYPAD HANDLE 1 WALL STOP 3 SILENCERS SET 4A 3 HINGE PRIVACY 1 PRIVACY SET 1 GASKETING SET (HEAD & JAMBS) 1 WALL STOP PE R S C H E D U L E DO O R H E I G H T 2 " 2" PER SCHED WIDTH 2" TYPE '1' Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:18:57 AM A1.1 FI R S T F L O O R P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS TRUE NORTH PLAN NORTH 3/8" = 1'-0"A1.1 1 FIRST FLOOR PLAN 1/4" = 1'-0" DOOR & FRAME ELEVATIONS 12" = 1'-0" HARDWARE SETS DOOR AND FRAME SCHEDULE MARK DOOR FRAME HDWR SET FIRE RATING (MIN.) GLASS TYPE PANIC HDWR COMMENTS NUMBER WIDTH HEIGHT THICK TYPE MAT'L FINISH MAT'L FINISH TYPELEAF 1 LEAF 2 103 3' - 0" 7' - 0" 0' - 1 3/4" F WOOD STAIN HM PAINT 1 2A No 103 105 3' - 0" 7' - 0" 0' - 1 3/4" F HM PAINT HM PAINT 1 1B 45 MIN. No OWNER TO PROVIDE KEYMARK HARDWARE 105 NOTES: 1. DOOR LOCKSETS TO BE SCHLAGE. 2. LOCKSET CYLINDERS TO BE KEYMARK (PROVIDED BY OWNER). 3. PROVIDE SIGNAGE FOR DOOR E104 THAT COMPLIES WITH IBC SEC 1010.1.9.3 "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED"1 Revision Number Revision Date 1 2/18/2020 DOOR 104 REMOVED FROM SCOPE 1 Reviewed by SAFEbuilt 02/19/2020 R1 1. ROOFS NOTES EXISTING ROOF IS EPDM ROOF MEMBRANE PATCH AND REPAIR ALL NEW ROOF PENETRATIONS SYSTEM NOTES EX. EX. EX. EX. EX. EX. EX. EX. TENANT FINISH SPACE REMOVE EXISTING CONDENSER (PATCH & REPAIR ROOF) PLACE NEW RTU OVER EXISTING BEARIING WALL CONDENSING UNITS FOR WALK-IN COOLERS, POSITION OVER TRASH ENCLOSURE ROOM WALL 27'-0" 16 ' - 1 0 " Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:18:58 AM A2.1 RO O F P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS 3/16" = 1'-0"A2.1 1 ROOF PLAN Revision Number Revision Date Reviewed by SAFEbuilt 02/19/2020 BH BH C5 3. 2. 1. C3 C4 CEILINGS NOTES EXPOSED STRUCTURE (DECK) - PAINTED 2'x2' SUSPENDED ACOUSTICAL CEILING TILE SYSTEM - PROVIDE COST OPTIONS FOR ARMSTRONG OPTIMA & ULTIMA LAY-IN, OR APPROVED EQUAL W/ .70 NRC OR GREATER, WASHABILITY, SCRUBABILITY, WHITE. AT S.A.T. CEILINGS, EXTEND GYPSUM BOARD TO ABOVE CEILING. AT GYP. BD. CEILINGS, TERMINATE GYP. BD. AT CEILING UNLESS OTHERWISE NOTED. SEE INTERIOR ELEVATION AND OR SECTIONS FOR MOUNTING HEIGHTS OF ALL WALL MOUNTED FIXTURE. ALL S.A.T. CEILINGS TO BE STANDARD 15/16" WHITE METAL TEE GRID. U.N.O. EXPOSED STRUCTURE (DECK) - UNPAINTED SYSTEM NOTES ELEVATION IDENTIFICATION 2'x4' LAY-IN FIXTURE 2'x2' LAY-IN FIXTURE 4' SURFACE MOUNTED LIGHT FIXTURE RECESSED CAN LIGHT PENDANT LIGHT FIXTURE EXIT LIGHT SUPPLY DIFFUSER RETURN DIFFUSER EXHAUST FAN GRILL 2'x2' SUSPENDED ACOUSTICAL CEILING LEGEND 5'- 6 " 2'- 6 " 6'-0" 6'-0" 4'-2 1/2" COMPASSO EDGE C5 10' - 6" CUSTOMER 101 F.O.H. PREP 102 B.O.H. 103 C5 10' - 6" C4 OPEN SIGN, PLAN FOR OUTLET OPEN SIGN, PLAN FOR OUTLET TV'S TO BE CEILING HUNG FAN/LIGHT COMBO NOT IN SCOPE NOT IN SCOPE NEW EGRESS DOWNLIGHT W/ BATTERY BACKUP (CENTERED IN SOFFIT) 1 COMMON HALL TRASH ENCLOSURE COMMON AREA SUBWAY B.O.H. SUBWAY CUSTOMER AREA STAIR ACCESS TO 2ND FLOOR COMPASSO EDGE, 6" HIGH (WHITE) 2x2 ACOUSTIC CEILING TILE PAINT STRUCTURE ABOVE FLAT BLACK PAINT WIRE HANGERS FLAT BLACK Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:18:59 AM A3.1 FI R S T F L O O R RE F L E C T E D CE I L I N G P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS 1/4" = 1'-0"A3.1 1 FIRST FLOOR RCP 1" = 1'-0"A3.1 15 COMPASSO EDGE DETAIL Revision Number Revision Date 1 2/18/2020 Reviewed by SAFEbuilt 02/19/2020 WH WH CUSTOMER 101 TB-1 PT-1 F.O.H. PREP 102 TB-1 PT-1 B.O.H. 103 TB-1 PT-1 A8.4 17 1619 A8.4 12 11 6 13 A8.4 8 7 10 9 14 STAINLESS STEEL BRAKE METAL WRAPPED AROUND ENDS OF OPENINGS, FROM FLOOR TO 96" AFF CG FRP-1 FR P - 1 FR P - 1 NOT IN SCOPE NOT IN SCOPE WF-1RBL-1 RBL-1 RBL-1 WF-1 WF-1RBL-1 RB L -1 RB L -1 STAINLESS STEEL BRAKE METAL WRAPPED AROUND ENDS OF OPENINGS, FROM FLOOR TO 96" AFF Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:19:01 AM A8.2 FI R S T F L O O R FI N I S H P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS 3/8" = 1'-0"A8.2 1 FINISH PLAN BASE NO. MATERIAL MANUFACTURER PRODUCT NAME / # COLOR NAME / # REMARKS TB-1 TILE BASE CROSSVILLE CROSS-COLORS MINGLES GRAPHITE A850 TEXTURE CROSS TREAD (CTS), INSTALLED PRIOR TO FLOOR TILE FLOORS NO. MATERIAL MANUFACTURER PRODUCT NAME/# COLOR NAME/# REMARKS CT-1 CERAMIC WALL TILE MS INTERNATIONAL METRO 12X24 CHARCOAL STACK BOND, 1/16" GROUT JOINT CT-2 CERAMIC WALL TILE DALTILE FESTIVA GREEN APPLE QF30 3X6 TILE, STRETCHER BOND LAYOUT (BRICK PATTERN) PT-1 PORCELAIN FLOOR TILE CROSSVILLE CROSS-COLORS MINGLES GRAPHITE A850 TEXTURE CROSS-TREAD (CTS), INSTALLED AFTER COVE TILE BASE OTHER FINISHES NO. MATERIAL MANUFACTURER PRODUCT NAME / # COLOR NAME / # REMARKS AT-1 ACOUSTIC TILE FILZ FELT 3MM WOOL DESIGN FELT 175 GRAPHITE, 423 HELLGRAU, 377 MAIGRUN CG-1 CORNER GUARD STAINLESS STEEL FRP-1 FIBER REINFORCED PANEL WHITE RBL-1 ROLLER BLINDS TS-1 TRANSITION STRIP SCHLUTER JOLLY BRUSHED CHROME WF-1 WINDOW FILM BLACK 100% OPAQUE FILM WALLS NO. MATERIAL MANUFACTURER PRODUCT NAME / # COLOR NAME / # REMARKS P-1 PAINT SHERWIN WILLIAMS LATEX EG-SHELL 7646 FIRST STAR INTAJUICE MAIN COLOR P-2 PAINT SHERWIN WILLIAMS LATEX EG-SHELL 7649 SILVER PLATE COMMON AREA & RESTROOMS P-3 PAINT SHERWIN WILLIAMS ACRYLIC SEMI-GLOSS 7067 CITYSCAPE DOOR FRAMES, STAIRS, RAILINGS P-4 PAINT SHERWIN WILLIAMS DRYFALL FLAT 7062 ROCK BOTTOM DRYFALL CEILINGS/STRUCTURE WD-1 RECYCLED WOOD WALL TILE EVERITT & SCHILLING CO. NOKOMIS NATURAL UNFINISHED 1 1 1 Revision Number Revision Date 1 2/18/2020 Reviewed by SAFEbuilt 02/19/2020 P- P- TB-1 OPEN P-4 WD-1 CT-1 P- TS-1 TB-1 CT-1 CT-2 P- TS- TB-1 2'-8 1/2"4'-0"18'-10 1/2" P- P- TB-1 TB-1 FRP-1 CG-1 WALK IN FREEZER WALK IN COOLER TB-1 FRP-1 TB-1 FRP-1 OPEN TB-1 CG-1 FRP-1 TB-1 FRP-1 P-2 TB-1 P-2 TB-1 FRP-1 P-2 TB-1 FRP-1 P-2 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:19:03 AM A8.4 IN T E R I O R F I N I S H EL E V A T I O N S IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS 3/8" = 1'-0"A8.4 14 FOH - NORTH 3/8" = 1'-0"A8.4 16 FOH - EAST 3/8" = 1'-0"A8.4 17 FOH - SOUTH 3/8" = 1'-0"A8.4 19 FOH - WEST 3/8" = 1'-0"A8.4 6 BOH - NORTH 3/8" = 1'-0"A8.4 11 BOH - EAST 3/8" = 1'-0"A8.4 12 BOH - SOUTH 3/8" = 1'-0"A8.4 13 BOH - WEST 3/8" = 1'-0"A8.4 7 RR 104 - NORTH 3/8" = 1'-0"A8.4 8 RR 104 - EAST 3/8" = 1'-0"A8.4 9 RR 104 - SOUTH 3/8" = 1'-0"A8.4 10 RR 104 - WEST Revision Number Revision Date Reviewed by SAFEbuilt 02/19/2020 WH UP WH RBC60 ICS BC60 RBC60 JD JD WGJ VJ CAB60 B CAB60 POS POS CAB60 DGC WIC WIF IM S3024 BBB SG E104 TR HAND SINK VEGGIE SINK 4-COMP SINK FLOOR ACCESS HATCH MOP SINK B OJ DB63 4'- 1 " 6'-0" RBR REMOVABLE CHAIN FOR LINE MANAGEMENT NOT IN SCOPE NOT IN SCOPE RR RR RR IB RBC60 HALF WALL TO RECEIVE STAINLESS STEEL WALL CAP FLOOR SINK FLOOR SINKFLOOR SINK HAND SINK VEGGIE SINK BC48 EL E C P A N E L DRAINBOARD MOUNTED ABOVE SINK, FULL WIDTH COMMON AREA SUBWAY B.O.H. COMMON HALL STAIR ACCESS TO 2ND FLOOR TRASH ENCLOSURE CUSTOMER 101 F.O.H. PREP 102 B.O.H. 103 S4824 STAIR ACCES TO BASEMENT SUBWAY CUSTOMER AREA 1 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: 11/15/2019 12/04/2019 11/1/2019 Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 7:19:05 AM A9.1 EQ U I P M E N T P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 19040 CONTRACT DOCUMENTS EQUIPMENT SCHEDULE NO. EQUIPMENT NAME LOCATION SPEC'D SUPPLY INSTALL HEIGHT WIDTH DEPTH SUPPORT REMARKSPOWER HVAC PLUMBING B F- BLENDTEC BLENDER OWNER OWNER OWNER 2' 0" 0' 8" 0' 9" 15A, 1800W -- -- -- BC48 P- 48" DUKE BACK COUNTER OWNER OWNER CONTR 2' 8" 4' 0" 2' 6"---- BC60 P- 60" DUKE BACK COUNTER OWNER OWNER CONTR 2' 8" 5' 0" 2' 6"---- CAB60 CABINET, 60"OWNER OWNER OWNER 36" 60" 32" -- -- -- -- IB ICE BIN OWNER OWNER OWNER 10" 15.25" 20.375" -- -- -- -- ICS ICE CREAM STORAGE - DIPPING CABINET OWNER OWNER OWNER 34 1/8" 66 5/8" 30 1/8" 115/60/1, 5-15P, 7.3A -- WATER SUPPLY & FLOOR SINK INCLUDES DIPPER WELL IM ICE MAKER Small OWNER OWNER OWNER 39.52" 29.06" 27.17" 115/60/1 -- 14-80 PSI WATER IN -- JD JUICE DISPENSER OWNER OWNER OWNER 29.3" 15" 24.3" 115V/60 -- 0.375" SAE MALE FLARE, 50PSI DYNAMIC OPERATING PRESSURE -- POS Q- POS RBC60 P- 60" REGENCY BACK COUNTER OWNER OWNER CONTR 2' 8" 60" 18"---- RBC60 RBC60 - Under Refrigerator OWNER OWNER OWNER 40" 60.09375" 29.5" 6A, 60HZ, 120V/1 -- -- -- RR RETAIL DISPLAY RACK OWNER OWNER OWNER -- -- -- -- S4824 Baker's Rack 48 OWNER OWNER OWNER -- -- -- -- SG K- SNEEZE GUARD TR N- TRASH OWNER OWNER OWNER 32" 4' 1 -- -- -- -- VJ H- VEGGIE JUICER OWNER OWNER OWNER 21.30" 18.10" 12.20" 110V/60HZ, 10A -- ---- WGJ G- WHEATGRASS JUICER OWNER OWNER OWNER 11" 6" 10" 115 VAC, 50-60 HZ -- -- -- WIC S- 5'x6' WALK-IN FREEZER OWNER OWNER OWNER 103" 5' 0" 6'-0" 1-1/2HP 208-230/60/1 -- -- -- WIF S- 10'x6' WALK-IN FREEZER OWNER OWNER OWNER 103" 6' 10' 1-1/2HP 208-230/60/1 -- -- -- 3/8" = 1'-0"A9.1 1 EQUIPMENT PLAN Revision Number Revision Date 1 2/18/2020 Reviewed by SAFEbuilt 02/19/2020 SHEET NUMBER SHEET TITLE MECHANICAL DRAWING INDEX ...... TOTAL:5 ... M0.1 MECHANICAL INDEX, LEGEND AND NOTES 12 / 0 9 / 2 0 1 9 PE R M I T I S S U E ISSUED FOR REFERENCE ONLY ISSUED FOR CONSTRUCTION LOCATION:ESTES PARK, CO ALTITUDE: 7,500 FT DENSITY RATIO: 0.760 ASHRAE CLIMATE ZONE:5B OUTDOOR CONDITIONS:SUMMER DESIGN DB = 95 °F COINCIDENT WB = 61 °F WINTER DESIGN DB = -20 °F INDOOR CONDITIONS:SUMMER DESIGN DB = 75 °F WINTER DESIGN DB = 70 °F CODES:2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2012 IECC ALL APPLICABLE LOCAL AMENDMENTS VENTILATION:SEE VENTILATION SCHEDULE PER 2015 IMC. ENVELOPE CHARACTERISTICS:REFERENCE ARCHITECTURAL PLANS. DESIGN DATA SECTION REFERENCE NUMBER. SECTION SHEET NUMBER WORK NOTE DESIGNATION. EQUIPMENT DESIGNATION. PIPE ANCHOR,ALIGNMENT GUIDE DUCT TRANSITION COMBINATION FIRE/SMOKE DAMPER. HUMIDITY SENSOR TEMPERATURE SENSOR. CHECK VALVE PIPE CAP, BLIND FLANGE PIPE DOWN AND PIPE TEE DOWN PIPE UP AND PIPE TEE UP PRESSURE REDUCING VALVE BALANCING VALVE A 8"Ø 200 ALL SYMBOLS IN LEGEND MAY NOT BE USED ON THIS PROJECT. MECHANICAL LEGEND ABBREVIATIONS SHEET METAL FITTINGS AND EQUIPMENT PIPING DESIGNATIONS AND FITTINGS HEATING WATER SUPPLY HEATING WATER RETURN HEAT RECOVERY SUPPLY HEAT RECOVERY RETURN CHILLED WATER SUPPLY CHILLED WATER RETURN CONDENSER WATER SUPPLY CONDENSER WATER RETURN LOW PRESSURE STEAM STEAM (CONDENSATE) RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION REFRIGERANT HOT GAS CONDENSATE DRAIN PUMPED CONDENSATE DRAIN RADIANT HEATING SNOWMELT ARROW IN LINE INDICATES DIRECTION OF FLOW HWS HWR HRS HRR CHWS CHWR CWS CWR LPS LPR RL RS RHG CD PCD RH AD ACCESS DOOR AFF ABOVE FINISH FLOOR AFMS AIR FLOW MEASURING STATION AFUE ANNUAL FUEL UTILIZATION EFFICIENCY AHU (AH)AIR HANDLING UNIT AP ACCESS PANEL BAS BUILDING AUTOMATION SYSTEM BOD BOTTOM OF DUCT BOP BOTTOM OF PIPE BHP BRAKE HORSE POWER BMS BUILDING MANAGEMENT SYSTEM BTU BRITISH THERMAL UNIT CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CO CARBON MONOXIDE CO2 CARBON DIOXIDE COP COEFFICIENT OF PERFORMANCE CU CONDENSING UNIT CV CONSTANT VOLUME CWP CONDENSER WATER PUMP DB DRY BULB TEMPERATURE dB DECIBEL DDC DIRECT DIGITAL CONTROL DN DOWN DP DIFFERENTIAL PRESSURE DS DUCT SUMP DX DIRECT EXPANSION (E)EXISTING EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO EFF EFFICIENCY ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK EWT ENTERING WATER TEMPERATURE °F DEGREES FAHRENHEIT FCU (FC)FAN COIL UNIT FLA FULL LOAD AMPS FPM FEET PER MINUTE FPS FEET PER SECOND FT FEET GAL GALLONS GPH GALLONS PER HOUR GPM GALLONS PER MINUTE HD HEAD HP HORSE POWER HR HOUR HZ HERTZ IN INCH I.E.INVERT ELEVATION KW KILOWATT KWH KILOWATT-HOUR LAT LEAVING AIR TEMPERATURE LBS POUNDS LF LINEAR FEET LWT LEAVING WATER TEMPERATURE MAT MIXED AIR TEMPERATURE MBH 1000 BRITISH THERMAL UNITS PER HOUR MCA MINIMUM CIRCUIT AMPS MERV MINIMUM EFFICIENCY REPORTING VALUE MOCP MAXIMUM OVER CURRENT PROTECTION NA NOT APPLICABLE NC NORMALLY CLOSED NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NO NORMALLY OPEN NPSHA NET POSITIVE SUCTION HEAD AVAILABLE NPSHR NET POSITIVE SUCTION HEAD REQUIRED OA OUTSIDE AIR P PUMP PCF POUND PER CUBIC FOOT PD PRESSURE DROP PH PHASE PPM PARTS PER MILLION PRV PRESSURE REDUCING VALVE PSI POUND PER SQUARE INCH PSIA POUND PER SQUARE INCH ABS. PSIG POUND PER SQUARE INCH GAUGE RA RETURN AIR RH RELATIVE HUMIDITY RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT SEER SEASONAL ENERGY EFFICIENCY RATIO SA SUPPLY AIR SP STATIC PRESSURE SQ FT SQUARE FEET TAB TESTING AND BALANCING TDH TOTAL DEVELOPED HEAD TEL TOTAL EQUIVALENT LENGTH TSP TOTAL STATIC PRESSURE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UV ULTRA VIOLET V VOLT VAV VARIABLE AIR VOLUME VD VOLUME DAMPER (MANUAL) VFD VARIABLE FREQUENCY DRIVE VTR VENT THRU ROOF WB WET BULB TEMPERATURE WC WATER COLUMN WPD WATER PRESSURE DROP (N)NEW (E)EXISTING (F)FUTURE (REL)RELOCATED EF X DUCT TRANSITION SQUARE TO ROUND DUCT TRANSITION # ISOLATION VALVE AIRFLOW - SUPPLY AIRFLOW - RETURN OR EXHAUST MANUAL VOLUME DAMPER MANUAL VOLUME DAMPER WITH REMOTE OPERATION FIRE DAMPER. SMOKE DAMPER. MOTORIZED CONTROL DAMPER ## @-### DEMOLITION NOTE DESIGNATION. POINT OF CONNECTION. NEW TO EXISTING AIR DEVICE DESIGNATION EXISTING DUCTWORK / PIPING TO REMAIN EXISTING DUCTWORK / PIPING TO BE REMOVED. NECK SIZE DEVICE TYPE AIRFLOW RETURN AIR GRILLE SUPPLY AIR DIFFUSER EXHAUST AIR GRILLE SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN DUCT UP RETURN DUCT DOWN EXHAUST DUCT UP EXHAUST DUCT DOWN LINEAR SLOT DIFFUSER SYMBOLS AND DESCRIPTIONS TEMPERATURE TRANSMITTER CARBON MONIXIDE SENSOR. CARBON DIOXIDE SENSOR. INDOOR AIR QUALITY SENSOR. # FS F S M TWO-WAY CONTROL VALVE THREE-WAY CONTROL VALVE TEST PORT, UNION THERMOMETER, PRESSURE GAUGE WELL, MANUAL AIR VENT STRAINER PLUG VALVE SM A 4FL/8"Ø 200 LINEAR SLOT DESIGNATION SLOT LENGTH AX-XX-H TERMINAL UNIT TAG AHU OR MAU DESIGNATION BOX DESIGNATION REHEAT DESIGNATION REB 200 REBALANCE EXISTING DIFFUSER DYNAMIC VALVE X" PIPE TYPE (XXX) XXX = GPM OF FLOW FOR PIPING PIPING NOTATION OCCUPANCY SENSOR. MECHANICAL GENERAL NOTES 1.DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY. WHATEVER IS CALLED FOR IN EITHER IS BINDING AS THOUGH CALLED FOR IN BOTH. 2.ALL WORK SHALL CONFORM WITH ALL APPLICABLE BUILDINGS CODES, FIRE CODES, AND ALL AUTHORITIES HAVING JURISDICTION. 3.THE EQUIPMENT SPECIFIED ON THE DRAWINGS HAVE BEEN SELECTED AS THE BASIS OF DESIGN. THE USE OF REVIEWED OR SPECIFIED EQUALS SHALL BE COORDINATED BY THE CONTRACTOR FOR SPACE REQUIREMENTS, EQUIPMENT DIMENSIONS, AND PERFORMANCE. 4.DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL DESIGN INTENT, ARRANGEMENT, AND GENERAL EXTENT OF SYSTEMS. DO NOT SCALE DRAWINGS NOR USE AS SHOP DRAWINGS. WHERE ALTERNATIVE ROUTING, OFFSETS, AND TRANSITIONS ARE REQUIRED FOR FIELD COORDINATION OF ALL OTHER TRADES, THIS CONTRACTOR SHALL FIELD COORDINATE WITH ALL OTHER TRADES, AND SHALL MAKE CHANGES WITHOUT ADDITIONAL COSTS. 5.CONTRACTOR SHALL CLOSELY COORDINATE NEW MECHANICAL WORK WITH ALL NEW AND EXISTING MECHANICAL, PLUMBING, ELECTRICAL, FIRE PROTECTION, ARCHITECTURAL, AND STRUCTURAL MEMBERS. RELOCATE EXISTING MECHANICAL, PLUMBING AND FIRE PROTECTION WORK AS REQUIRED TO ACCOMMODATE ALL NEW WORK (ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, FIRE ALARM, LOW VOLTAGE, A/V, ETC. 6.ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION UNLESS SPECIFICALLY DIRECTED OTHERWISE. 7.COORDINATE ALL DIFFUSER AND GRILLE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS, FIRE PROTECTION AND ELECTRICAL DRAWINGS. 8.INSTALL CONDENSATE DRAINS FOR ALL COOLING COILS WITH TRAP DEPTH EQUAL TO 1.5 TIMES THE UNIT'S TOTAL STATIC PRESSURE. DISCHARGE CONDENSATE TO FLOOR SINK/FLOOR DRAIN UNLESS NOTED OTHERWISE. 9.ALL ROOF WORK SHALL BE PER THE ROOFING MANUFACTURE'S INSTALLATION INSTRUCTIONS TO MAINTAIN THE EXISTING ROOF WARRANTY. 10.CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION AND INSTALLING SLEEVES, INSERTS AND SUPPORTS AS REQUIRED FOR THIS SCOPE OF WORK AND/OR CORE DRILL REQUIREMENTS. COORDINATE WITH GENERAL CONTRACTOR AND STRUCTURAL ENGINEER AS REQUIRED. 11.CONTRACTOR SHALL FIELD VERIFY ALL MECHANICAL ITEMS PRIOR TO SUBMITTING A BID. 12.THE MECHANICAL DIAGRAMS SHALL BE INCORPORATED INTO THE ASSOCIATED WORK AND PROVIDE GENERAL GUIDANCE AS TO THE INSTALLATION INTENT WHETHER REFERENCED TO OR NOT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY COMPONENTS FOR A COMPLETE INSTALLATION, AND INSURE THAT ALL INSTALLATIONS ARE IN ACCORDANCE WITH THE EQUIPMENT'S MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. 13.WHERE PIPING AND/OR DUCTWORK IS TO BE REMOVED TO A POINT, IT SHALL BE CAPPED OFF AND PROTECTED (WHERE APPLICABLE) FOR CONNECTION TO NEW WORK. INSULATION ON EXISTING PIPING AND DUCTWORK SHALL BE REPAIRED EQUAL TO NEW CONDITION. 14.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND PATCHING OF DAMAGED ARCHITECTURAL COMPONENTS TO REMAIN DURING THE REMOVAL OF THE DESIGNATED SYSTEMS. COORDINATE REPAIR WITH ARCHITECT. 15.THE OWNER RESERVES FIRST CHOICE TO KEEP EXISTING EQUIPMENT AND MATERIALS. COORDINATE WITH OWNER AND DELIVER DESIGNATED EQUIPMENT AND MATERIALS REMOVED UNDER THIS CONTRACT TO OWNERS DESIGNATED STORAGE AREA. 16.THE LOCATION AND CONDITION OF THE EXISTING PROPERTY AND MECHANICAL SYSTEMS WERE TAKEN FROM PREVIOUS CONSTRUCTION DRAWINGS, OBSERVED FIELD CONDITIONS, AND ASSUMED FIELD CONDITIONS. CERTAIN ASSUMPTIONS MAY BE MADE REGARDING EXISTING CONDITIONS BECAUSE THE ASSUMPTION MAY NOT BE VERIFIED WITHOUT DESTROYING THE EXISTING SPACE. CONTRACTOR SHALL VERIFY EXISTING SYSTEMS PRIOR TO SUBMITTING FINAL BIDS, FABRICATION, OR SUBMITTALS. MECHANICAL DUCT SYSTEM NOTES 1.DUCT SIZES AS INDICATED ON THE DRAWINGS ARE OUTSIDE SHEET METAL DIMENSIONS. WHERE DUCT LINER IS USED THE DUCTWORK DIMENSIONS ACCOMMODATE THE DUCT LINER. 2.CONTRACTOR SHALL CONSTRUCT AND INSTALL DUCTWORK PER SMACNA STANDARDS. 3.BRANCH DUCT CONNECTIONS TO DIFFUSERS SHALL BE THE SAME SIZE AS THE DIFFUSER NECK UNLESS NOTED OTHERWISE. 4.SPIN-IN FITTINGS TO DIFFUSERS SHALL BE CONICAL TYPE (EXCEPT LOCATIONS WHERE LISTED DUCT HEIGHT DOES NOT ACCOMMODATE). 5.DAMPERS: SINGLE BLADE TYPE VOLUME DAMPERS SHALL BE INSTALLED AT ALL DIFFUSER TAKEOFFS AND WHERE REQUIRED FOR PROPER BALANCING. HANDLE SHALL BE VISIBLE THROUGH INSULATION. 6.PROVIDE A MINIMUM 12” LONG RED RIBBON LOCATOR ON VOLUME DAMPER VALVE HANDLES. 7.SPIRAL EXPOSED DUCTWORK SHALL BE GALVANIZED SHEET STEEL SPIRAL. PROVIDE MILL PHOSPHATIZED FINISH THAT IS FREE FROM VISUAL IMPERFECTIONS, INCLUDING PITTING, SEAM MARKS, ROLLER MARKS, STAINS, DENTS AND DISCOLORATIONS, INCLUDING THOSE THAT WOULD IMPAIR PAINTING. 8.RECTANGULAR DUCT TURNS/ELBOWS: ALL 90 DEGREE ELBOWS SHALL BE LONG RADIUS ELBOWS OR SHALL HAVE TURNING VANES CONSISTING OF SINGLE BLADE DUCT VANES WITH 2-1/2 INCH BLADE SPACING. 9.INSULATED FLEXIBLE DUCT MAY BE USED FOR THE CONNECTION TO SUPPLY AIR OUTLETS/DIFFUSERS PROVIDED THE FLEXIBLE CONNECTION DOES NOT EXCEED 6 LINEAR FEET IN LENGTH. INSTALL DUCTS FULLY EXTENDED. DO NOT INSTALL IN THE COMPRESSED STATE OR USE EXCESS LENGTH. DUCT SCHEDULE MATERIAL PRESSURE CLASS MINIMUM SMACNA SEAL CLASS SMACNA LEAKAGE CLASS FOR RECT. SMACNA LEAKAGE CLASS FOR ROUND DUCT SYSTEM NOTES SUPPLY AND RETURN DUCTS UPSTREAM AND DOWNSTREAM OF FANS WITH LESS THAN 2" ESP GALVANIZED STEEL 4-INCH WG B 24 12 ALL EXTERIOR DUCTWORK TO BE SEAL CLASS A EXHAUST DUCTS UPSTREAM AND DOWNSTREAM OF FANS WITH LESS THAN 2" ESP GALVANIZED STEEL 2-INCH WG B 24 12 INSULATION SCHEDULE SYSTEM LINER/WRAP THICKNESS (IN) DENSITY (LBS/FT3) MINIMUM R-VALUE NOTES FIRST 20 FEET FROM AIR HANDLING UNITS, AND ROOFTOP UNITS SUPPLY LINER 1"1.5 R-8 RETURN LINER 1"1.5 R-8 DUCTWORK IN UNVENTILATED ATTIC (NO RA PLENUM) SUPPLY WRAP 2"0.75 R-6 WITH FSK FACING RETURN WRAP 2"0.75 R-6 WITH FSK FACING EXPOSED SPIRAL DUCT SUPPLY/ RETURN NONE N/A N/A N/A UNLESS NOTED ON PLANS ALL OTHER EXHAUST EXHAUST NONE N/A N/A N/A REL 200 RELOCATE AND REBALANCE EXISTING DIFFUSER M0.2 MECHANICAL SCHEDULES AND DIAGRAMS M1.1 FLOOR PLAN - MECHANICAL M2.1 ROOF PLAN - MECHANICAL M0.3 MECHANICAL SPECIFICATIONS 5 02 / 1 9 / 2 0 2 0 PL A N R E V I E W C O M M E N T S 1 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 M0.1 ME C H A N I C A L IN D E X , L E G E N D A N D NO T E S 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 NOTES: 1.FOR DUCTS OVER 48" WIDE, BOTTOM SHALL BE ANGLE BRACED. FOR CROSS SECTION AREA GREATER THAN 8 SQUARE FEET, DUCT SHALL BE ANGLE BRACED ON ALL FOUR SIDES. 2.SUPPORTS SHALL BE SPACED AND SIZED PER SMACNA STANDARDS. 3.REFERENCE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, 60" MAXIMUM OVER 60" 1" GALVANIZED HANGER THREADED HANGER ROD HANGER STRAP UNISTRUT OR ANGLE IRON DUCT CEILING DIFFUSER INSTALLATION DIFFUSER / REGISTER INSULATED SQUARE TO ROUND ADAPTER WHERE REQUIRED EQUAL TO OR GREATER THAN DIAMETER OF FLEXIBLE DUCT MAXIMUM 6'-0" LONG FLEXIBLE DUCT (TYP.) STAINLESS STEEL BAND OR NYLON STRAP (TYP.) MIN 3" WIDE SHEET METAL STRAP NOTES: 1.EXHAUST AIR REGISTERS SIMILAR WITH RIGID DUCT IN LIEU OF FLEX. 2.FOR CEILING SPACES WITHOUT CLEARANCE FOR PROPER BEND AT FLEX DUCT, PROVIDE FULL SIZE INSULATED SHEET METAL ELBOW WITH TURNING VANES FOR SIDE CONNECTION TO DUCTWORK. WATERTIGHT GASKET ALL AROUND UNIT CASING COUNTERFLASHING WITH DRIP FACTORY SUPPLIED ROOF CURB WITH FIELD SUPPLIED RIGID INSULATION PRESSURE TREATED CANT STRIP ALL AROUND ROOF INSULATION ROOFING FELT ROOF STRUCTURE HARDWOOD OR STEEL SHIMS BETWEEN ROOF DECKING AND SUPPORT STRUCTURE WOOD NAILER (SUPPLIED WITH CURB) ROOF INSULATION 2 LAYERS 5/8" GYP. BOARD NOTES: 1.ROOFING MEMBRANE TO BE FLASHED WATERTIGHT TO THE CURB (BY GENERAL CONTRACTOR). 2.CUTTING OF THE ROOF ASSEMBLY TO ACCOMMODATE DUCT PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 3.SEAL ALL AROUND BETWEEN DUCT(S) AND GYPSUM BOARD WITH AN APPROVED ACOUSTIC SEALANT (BY GENERAL CONTRACTOR). 4.SEAL AROUND FULL PERIMETER OF CURB / GYPSUM BOARD INTERFACE WITH AN APPROVED ACOUSTIC SEALANT (BY GENERAL CONTRACTOR). 1N.TS.3N.TS.RTU ROOF CURB 2N.TS.DUCT HANGER SUPPORT 1 11 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 M0.2 ME C H A N I C A L SC H E D U L E S A N D DI A G R A M S 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 MECHANICAL SPECIFICATIONS GENERAL 1.1 MECHANICAL GENERAL REQUIREMENTS: 1.1.1 PROVIDE ALL ITEMS FOR COMPLETE AND SUCCESSFUL OPERATION OF ALL MECHANICAL SYSTEMS. 1.1.2 DEMONSTRATE THE OPERATION OF ALL SYSTEMS FOR THE OWNER AT A TIME AS DIRECTED BY THE OWNER. 1.1.3 FIELD VERIFY ALL EXISTING CONDITIONS AND INCLUDE AN ALLOWANCE IN BID FOR REMOVAL AND/OR RELOCATION OF EXISTING PIPING, DUCTWORK, EQUIPMENT, ETC. AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING SYSTEMS TO ALL OTHER WORK. CONTRACTORS SHALL VERIFY OPERATIONAL CONDITION OF ALL EQUIPMENT LOCATED WITHIN THE AREA PRIOR TO BEGINNING WORK. THE CONTRACTORS SHALL PREPARE A LIST OF DEFICIENCIES FOR THE PROPERTY MANAGER/OWNER PRIOR TO THE START OF CONSTRUCTION. THIS LIST SHALL ALSO INCLUDE ANY ITEMS THAT WERE NOT, OR COULD NOT BE VERIFIED. 1.1.4 REPLACE ANY WORK OR MATERIAL INSTALLED OR FURNISHED UNDER THIS CONTRACT WHICH DEVELOPS DEFECTS, EXCEPT FOR NORMAL WEAR, WITHIN ONE (1) YEAR AFTER CERTIFICATE OF COMPLETION IS SECURED. RETURN DEFECTIVE MATERIALS TO OWNER. 1.1.5 CONTRACTOR SHALL OBTAIN OWNER OR BUILDING MANAGEMENT APPROVAL BEFORE CUTTING ANY FLOOR PENETRATIONS. 1.1.6 THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH. IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND/OR OWNER AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. 1.2 INSPECTION OF SITE: 1.2.1 PRIOR TO SUBMITTING BID, VISIT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 1.3 MATERIAL AND WORKMANSHIP: 1.3.1 PROVIDE NEW MATERIAL, EQUIPMENT, AND APPARATUS UNDER THIS CONTRACT UNLESS OTHERWISE STATED HEREIN, OF BEST QUALITY NORMALLY USED FOR THE PURPOSE IN GOOD COMMERCIAL PRACTICE, AND FREE FROM ANY DEFECTS. MODEL NUMBERS LISTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS ARE NOT NECESSARILY INTENDED TO DESIGNATE THE REQUIRED TRIM, WRITTEN DESCRIPTIONS OF THE TRIM GOVERN MODEL NUMBERS. 1.3.2 WORK PERFORMED UNDER THIS CONTRACT SHALL PROVIDE A NEAT AND "WORKMANLIKE" APPEARANCE WHEN COMPLETED, TO THE SATISFACTION OF THE ARCHITECT AND ENGINEER. WORKMANSHIP SHALL BE THE FINEST POSSIBLE BY EXPERIENCED MECHANICS. INSTALLATIONS SHALL COMPLY WITH APPLICABLE CODES AND LAWS. 1.3.3 THE COMPLETE INSTALLATION SHALL FUNCTION AS DESIGNED AND INTENDED WITH RESPECT TO EFFICIENCY, CAPACITY, NOISE LEVEL, ETC. ABNORMAL NOISE CAUSED BY RATTLING EQUIPMENT, PIPING, DUCTS, AIR DEVICES, AND SQUEAKS IN ROTATING COMPONENTS WILL NOT BE ACCEPTABLE. IN GENERAL, MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTED. 1.3.4 REMOVE FROM THE PREMISES WASTE MATERIAL PRESENT AS A RESULT OF WORK, INCLUDING CARTONS, CRATING, PAPER, STICKERS, AND/OR EXCAVATION MATERIAL NOT USED IN BACKFILLING, ETC. CLEAN EQUIPMENT INSTALLED UNDER THIS CONTRACT TO PRESENT A NEAT AND CLEAN INSTALLATION AT THE TERMINATION OF THE WORK. 1.3.5 REPAIR OR REPLACE PROPERTY DAMAGED AS A RESULT OF WORK PERFORMED UNDER THIS CONTRACT TO THE SATISFACTION OF AUTHORITIES AND REGULATIONS HAVING JURISDICTION. 1.4 COORDINATION: 1.4.1 COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT THE VARIOUS COMPONENTS OF THE SYSTEMS THAT ARE BEING INSTALLED AND/OR EXISTING SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO THOSE ITEMS REQUIRING MAINTENANCE. COMPONENTS WHICH ARE INSTALLED WITHOUT REGARD TO THE ABOVE SHALL BE RELOCATED AT NO ADDITIONAL COST TO THE OWNER. 1.4.2 UNLESS OTHERWISE INDICATED, THE GENERAL CONTRACTOR WILL PROVIDE CHASES AND OPENINGS IN BUILDING CONSTRUCTION REQUIRED FOR INSTALLATION OF THE SYSTEMS SPECIFIED HEREIN. MECHANICAL CONTRACTOR SHALL FURNISH THE GENERAL CONTRACTOR WITH INFORMATION WHERE CHASES AND OPENINGS ARE REQUIRED, KEEP INFORMED AS TO THE WORK OF OTHER TRADES ENGAGED IN THE CONSTRUCTION OF THE PROJECT, AND EXECUTE WORK IN A MANNER AS TO NOT INTERFERE WITH OR DELAY THE WORK OF OTHER TRADES. 1.4.3 FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALE DIMENSIONS. MECHANICAL CONTRACTOR SHALL TAKE HIS OWN MEASUREMENTS AT THE BUILDING, AS VARIATIONS MAY OCCUR. MECHANICAL CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION. 1.4.5 MECHANICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR DUCTWORK LAYOUT TO THE ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. 1.5 ORDINANCES AND CODES: 1.5.1 WORK PERFORMED UNDER THIS CONTRACT SHALL, AT A MINIMUM, BE IN CONFORMANCE WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES HAVING JURISDICTION. EQUIPMENT FURNISHED AND ASSOCIATED INSTALLATION WORK PERFORMED UNDER THIS CONTRACT SHALL BE IN STRICT COMPLIANCE WITH CURRENT APPLICABLE CODES ADOPTED BY THE LOCAL AHJ INCLUDING ANY AMENDMENTS AND STANDARDS AS SET FORTH BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), UNDERWRITERS LABORATORIES (UL), OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME), AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS (ASHRAE), AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM) AND OTHER NATIONAL STANDARDS AND CODES WHERE APPLICABLE. WHERE THE CONTRACT DOCUMENTS EXCEED THE REQUIREMENTS OF THEIR REFERENCED CODES, STANDARDS, ETC., THE CONTRACT DOCUMENTS SHALL TAKE PRECEDENCE. 1.5.2 PROCURE AND PAY FOR PERMITS AND LICENSES REQUIRED FOR THE ACCOMPLISHMENT OF THE WORK HEREIN DESCRIBED. WHERE REQUIRED, OBTAIN, PAY FOR AND FURNISH CERTIFICATES OF INSPECTION TO OWNER. MECHANICAL CONTRACTOR WILL BE HELD RESPONSIBLE FOR VIOLATIONS OF THE LAW. 1.6 PROTECTION OF EQUIPMENT AND MATERIALS: 1.6.1 STORE AND PROTECT FROM DAMAGE EQUIPMENT AND MATERIALS DELIVERED TO JOB SITE. COVER WITH WATERPROOF, TEAR-RESISTANT, HEAVY TARP OR POLYETHYLENE PLASTIC AS REQUIRED TO PROTECT FROM PLASTER, DIRT, PAINT, WATER, OR PHYSICAL DAMAGE. EQUIPMENT AND MATERIAL THAT HAS BEEN DAMAGED BY CONSTRUCTION ACTIVITIES WILL BE REJECTED, AND MECHANICAL CONTRACTOR IS OBLIGATED TO FURNISH NEW EQUIPMENT AND MATERIAL OF A L LIKE KIND AS APPROVED BY OWNER. 1.6.2 KEEP PREMISES ROOM CLEAN FROM FOREIGN MATERIAL CREATED DURING WORK PERFORMED UNDER THIS CONTRACT. PIPING, EQUIPMENT, ETC., SHALL HAVE A NEAT AND CLEAN APPEARANCE AT THE TERMINATION OF THE WORK. 1.6.3 PLUG OR CAP OPEN ENDS OF DUCTWORK AND PIPING SYSTEMS WHILE STORED OR INSTALLED DURING CONSTRUCTION WHEN NOT IN USE TO PREVENT THE ENTRANCE OF DEBRIS INTO THE SYSTEMS. 1.7 OPERATION AND MAINTENANCE INSTRUCTIONS: 1.7.1 COLLECT AND COMPILE A COMPLETE BROCHURE OF FIXTURES, MATERIALS, AND EQUIPMENT FURNISHED AND INSTALLED ON THIS PROJECT. INCLUDE OPERATIONAL AND MAINTENANCE INSTRUCTIONS, MANUFACTURER'S CATALOG SHEETS, WIRING DIAGRAMS, PARTS LISTS, APPROVED SHOP DRAWINGS, AND DESCRIPTIVE LITERATURE FURNISHED BY THE MANUFACTURER. INCLUDE AN INSIDE COVER SHEET THAT LISTS THE PROJECT NAME, DATE, OWNER, ARCHITECT, ENGINEER, GENERAL CONTRACTOR, SUBCONTRACTOR, AND AN INDEX OF CONTENTS. 1.7.2 SUBMIT COPIES OF LITERATURE BOUND IN APPROVED BINDERS TO THE ARCHITECT AND OWNER AT THE TERMINATION OF THE WORK. PAPER CLIPS, STAPLES, RUBBER BANDS, AND MAILING ENVELOPES ARE NOT CONSIDERED APPROVED BINDERS. FINAL APPROVAL OF MECHANICAL AND PLUMBING SYSTEMS WILL BE WITHHELD UNTIL THIS EQUIPMENT BROCHURE IS DEEMED COMPLETE BY THE ARCHITECT, ENGINEER, AND OWNER. 1.8 WARRANTIES: 1.8.1 WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. 1.8.2 WARRANTIES SHALL INCLUDE LABOR AND MATERIAL. MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. 1.8.3 PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ARCHITECT OR OWNER. 1.8.4 AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM LIMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 1.9 CUTTING AND PATCHING: 1.9.1 PERFORM CUTTING OF WALLS, FLOORS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. OBTAIN PERMISSION FROM THE ARCHITECT PRIOR TO CUTTING. DO NOT CUT OR DISTURB STRUCTURAL MEMBERS WITHOUT PRIOR APPROVAL FROM THE ARCHITECT. CUT HOLES AS SMALL AS POSSIBLE. GENERAL CONTRACTOR SHALL PATCH WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. PATCHING SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. REPAIR AND REFINISH AREAS DISTURBED BY WORK TO THE CONDITION OF ADJOINING SURFACES IN A MANNER SATISFACTORY TO THE ARCHITECT. 1.10 STRUCTURAL STEEL: 1.10.1 STRUCTURAL STEEL USED FOR PIPE SUPPORTS, EQUIPMENT SUPPORTS, ETC., SHALL BE NEW, CLEAN, AND CONFORM TO ASTM DESIGNATION A-36. 1.10.2 SUPPORT PLUMBING AND MECHANICAL EQUIPMENT AND PIPING FROM THE BUILDING STRUCTURE. DO NOT SUPPORT PLUMBING EQUIPMENT FROM CEILINGS, OTHER MECHANICAL OR ELECTRICAL COMPONENTS, AND OTHER NON-STRUCTURAL ELEMENTS. 1.11 PENETRATIONS: 1.11.1 SEAL FLOOR, EXTERIOR WALL AND ROOF PENETRATIONS WATER AND WEATHER TIGHT WITH APPROPRIATE NON-SHRINK, NON-HARDENING COMMERCIAL CONSTRUCTION SEALANT. SEALROOF PENETRATIONS WITH 4 POUND PER SQUARE FOOT LEAD FLASHING. PROVIDE A SLEEVE, AND SEAL NON-FIRE-RATED FLOOR AND WALL PENETRATIONS WITH FIBERGLASS PACKING AND SILICONE CAULK (FOR ACOUSTICAL INSULATION). 1.11.2 COORDINATE FIRE RATING REQUIREMENTS AND LOCATIONS WITH THE ARCHITECT. SEAL PENETRATIONS OF FIRE-RATED ASSEMBLIES WITH 3M # CP-25 FIRE BARRIER CAULK (PROVIDE THICKNESS AND METHOD AS REQUIRED AND RECOMMENDED BY MANUFACTURER) TO MAINTAIN THE FIRE RESISTANCE RATING OF FIRE-RATED ASSEMBLIES. HEATING, VENTILATION, AND AIR CONDITIONING 2.1 AIR DISTRIBUTION: 2.1.1 PROVIDE ALL SHEET METAL DUCT SYSTEMS, CONNECTIONS, DAMPERS, HOUSINGS, SHEET METAL DOORS FOR THE COMPLETE SUPPLY, RETURN, AND EXHAUST SYSTEMS. 2.1.2 ALL DUCTWORK IDENTIFICATION AND INSTALLATION TO ADHERE TO SMACNA STANDARDS AND ALL GOVERNING CODES. 2.1.3 METAL AND GAUGE: UNLESS SPECIFIED OTHERWISE GALVANIZED IRON SHALL BE USED THROUGHOUT, FABRICATED AND INSTALLED SO THAT NO VIBRATING OR NOISE RESULTS. SHEET STEEL SHALL BE OF THE US STANDARD GAUGE AS RECOMMENDED IN THE LATEST EDITION OF SMACNA. 2.1.4 DUCT WORKMANSHIP: ALL DUCTWORK SHALL BE CONSTRUCTED AND ERECTED IN A WORKMANLIKE MANNER. DUCTS SHALL BE STRAIGHT AND SMOOTH ON THE INSIDE WITH NEATLY FINISHED JOINTS, AIRTIGHT, AND SHALL BE FREE FROM VIBRATION UNDER ALL CONDITIONS OF OPERATION. THE INTERNAL ENDS OF SLIP JOINTS SHALL BE MADE IN THE DIRECTION OF AIRFLOW. DUCTS SHALL BE SECURELY ATTACHED TO THE BUILDING CONSTRUCTION IN AN APPROVED MANNER. 2.1.5 DUCT TURNS: ALL 90 DEGREE ELBOWS UP TO 18 INCHES WIDE AND ALL 45 DEGREE ELBOWS SHALL HAVE AN INSIDE RADIUS OF NOT LESS THAN ONE HALF THE WIDTH OF THE DUCT. 90 DEGREE ELBOWS WITH TURNING VANES SHALL BE USED CONSISTING OF SINGLE BLADE DUCT VANES WITH 2.5 INCH BLADE SPACING. 2.1.6 DAMPERS: SINGLE BLADE TYPE VOLUME DAMPERS SHALL BE INSTALLED AT DIFFUSER TAKEOFFS, AND WHERE REQUIRED FOR PROPER BALANCING. HANDLE SHALL BE VISIBLE THROUGH INSULATION. 2.1.8 GRILLES, REGISTERS, AND DIFFUSERS: PROVIDE SUPPLY, RETURN, AND EXHAUST REGISTERS AND DIFFUSERS AS NOTED ON THE EQUIPMENT SCHEDULE FOR THE TYPE, SIZE, MATERIAL, AND FINISH. 2.1.7 FLEX DUCT SHALL BE OWENS-CORNING FOIL-BACK HIGH QUALITY U/L APPROVED. PLASTIC WRAPPED FLEX DUCT IS NOT ACCEPTABLE. 2.2 INSULATION: 2.2.1 ALLOWABLE MANUFACTURERS: JOHNSONS-MANVILLE CORP. MANSON INSULATION CO. OWENS-CORNING OR APPROVED EQUAL. 2.2.1 DUCT INSULATION TO BE FIBERGLASS INSULATION, WITH VAPOR BARRIER, UL APPROVED, CLASS I AIR DUCT. 2.2.2 SEE DUCT SYSTEM NOTES AND INSULATION SCHEDULE FOR LOCATIONS AND INSULATION THICKNESSES. 2.2.3 ALL INSULATION SHALL MEET ALL CODE REQUIREMENTS AND FIRE AND SMOKE HAZARD RATINGS OF ASTM E-84, NATIONAL FIRE PROTECTION ASSOCIATION 225 AND UL 723, NOT EXCEEDING FLAME SPREAD 25 AND SMOKE DEVELOPED 50 RATINGS. 2.3 TESTING, ADJUSTING, AND BALANCING: 2.3.1 SUBMIT TEST REPORTS FOR TESTING, ADJUSTING, AND BALANCING. 2.3.2 TOTAL SYSTEM BALANCE SHALL BE PERFORMED IN ACCORDANCE WITH NEBB OR AABC PROCEDURAL STANDARDS. 2.3.3 BEFORE COMMENCING WORK, VERIFY THAT SYSTEMS ARE COMPLETE AND OPERABLE, WITH CLEAN FILTERS. 2.3.4 PROMPTLY REPORT ABNORMAL CONDITIONS IN MECHANICAL SYSTEMS OR CONDITIONS WHICH PREVENT SYSTEM BALANCE. 2.3.5 ADJUSTING AND BALANCING: 2.3.5.1 ADJUST AIR HANDLING SYSTEM TO WITHIN 10 PERCENT FROM INDICATED FIGURES. 2.3.5.2 RECORDED DATA SHALL REPRESENT MEASURED OR OBSERVED INITIAL CONDITION AND CONDITION AFTER BALANCING. 2.3.5.3PERMANENTLY MARK SETTINGS OF DAMPERS, AND OTHER ADJUSTMENT DEVICES ALLOWING SETTINGS TO BE RESTORED. 2.3.5.4LEAVE SYSTEMS IN PROPER WORKING ORDER, REPLACING BELT GUARDS, CLOSING ACCESSORY DOORS, CLOSING DOORS TO ELECTRICAL SWITCH BOXES, AND RESTORING THERMOSTATS TO SPECIFIED SETTINGS. 2.4 ELECTRICAL: 2.4.1 LOW VOLTAGE WIRING - ALL PROVISIONS FOR LOW VOLTAGE WIRING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR UNLESS CODES OR LABOR SITUATIONS DO NOT PERMIT. IF THE MECHANICAL CONTRACTOR CAN NOT PERFORM LOW VOLTAGE WIRING, THE MECHANICAL CONTRACTOR SHALL INFORM THE GENERAL CONTRACTOR, AS PART OF THE HVAC BID DOCUMENT, TO HAVE THE ELECTRICAL SUBCONTRACTOR INCLUDE THIS WORK IN THEIR BID. 2.4.2 POWER WIRING - ALL ELECTRICAL POWER WIRING TO INCLUDE FINAL CONNECTIONS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR'S ELECTRICAL SUBCONTRACTOR. 2.5 GAS PIPING: 2.5.1 SCHEDULE 40 BLACK CARBON STEEL WITH MALLEABLE IRON THREADED FITTINGS. PROVIDE SHUT-OFF VALVE, DIRT LEG, AND UNION AT EACH ROOFTOP UNIT. PAINT ALL GAS PIPING EXPOSED TO WEATHER WITH ONE COAT OF PRIMER, AND TWO COATS OF RUST-PROOF PAINT. COLOR SHALL MATCH BUILDING COLORS. COORDINATE WITH OWNER'S CONSTRUCTION MANAGER. 2.5.2 TREATED WOOD BLOCKING 6x6x12, 8'-0" OC MAS WITH GALVANIZED PIPE STRAP, 1-1/4" ZINC COATED LAG SCREWS AND RUBBER WALKPAD ADHERED TO ROOF. 2.6 MECHANICAL CONTRACTOR RESPONSIBILITIES: 2.6.1 AFTER COMPLETION OF THE WORK DESCRIBED IN THIS SPECIFICATION AND SHOWN ON THE DRAWINGS, THE MECHANICAL CONTRACTOR SHALL THOROUGHLY CLEAN ALL EXPOSED EQUIPMENT, REMOVING ALL LABELS AND STICKERS NOT CONTAINING OPERATION INSTRUCTION. MECHANICAL CONTRACTOR SHALL REMOVE CRATING DEBRIS, LEAVING THE INSTALLATION FINISHED AND READY FOR OPERATION, TO INCLUDING CLEAN FILTERS IN AIR HANDLING UNITS. Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 M0.3 ME C H A N I C A L SP E C I F I C A T I O N S 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 UP UP B.O.H. 103 F.O.H. PREP 102 CUSTOMER 101 RR 104 TRASH ENCLOSURE COMMON AREA A 10"Ø 225 (2) 16X14 SA 18x18 RA (1" LNR) B 18x8 400 (2) A 10"Ø 350 (2) EF 1 EF 2 C 18x18 8"Ø EA UP 1 2 328x16 RA (1" LNR) 12x12 SA 6"Ø EA UP 6"Ø EA 28x14 SA (1" LNR) 1 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 M1.1 FL O O R P L A N - ME C H A N I C A L SCALE: FLOOR PLAN - MECHANICAL 1/4" = 1'-0" TRUE1 M1.1 WORK NOTES:# 1.SUPPLY AND RETURN DUCT UP TO RTU. PROVIDE FLEX CONNECTION AND TRANSITION DUCTWORK AS REQUIRED. 2.PROVIDE 1" UNDERCUT AT DOOR. 3.3" FLUE AND COMBUSTION AIR UP THRU ROOF WITH CONCENTRIC VENT KIT. 4.PAINT DUCTWORK ABOVE CEILING IN PREP AREA PER ARCHITECTS SELECTED PAINT COLOR. 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 RTU 1 1 2" G ( 2 6 0 , 7 " W C ) 1-1/2" G (130, 7" WC) 2 3 1 4 1-1/2" G (130, 7" WC) 5 1 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 M2.1 RO O F P L A N - ME C H A N I C A L SCALE: ROOF PLAN - MECHANICAL 1/4" = 1'-0" TRUE1 M2.1 WORK NOTES:# 1.EXHAUST DUCT WITH ROOF CAP. 2.1-1/2" G DOWN. REFER TO SHEET P1.1 FOR CONTINUATION. 3.2" G CONTINUED TO EXISTING GAS METER BANK LOCATION. APPROXIMATE DISTANCE FROM THIS POINT TO METER BANK IS 200'. PLUMBING CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE FOR LOCATION. COORDINATE WITH GAS SERVICE PROVIDER FOR ADDITIONAL METER LOAD OF 260 MBH (325 CFH) AT A DELIVERY PRESSURE OF 7" WC. IF DELIVERY PRESSURE DIFFERS NOTIFY GENERAL CONTRACTOR AND ENGINEER. 4.CONDENSING UNITS FOR WALK IN COOLER/FREEZER. COORDINATE EXACT LOCATION WITH EQUIPMENT SUPPLIER AND ARCHITECT. 5.COORDINATE EXACT LOCATION OF RTU WITH ARCHITECTURAL DRAWINGS. 1 1 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 SHEET NUMBER SHEET TITLE PLUMBING DRAWING INDEX TOTAL:4 P0.1 PLUMBING INDEX, LEGEND AND NOTES 12 / 0 9 / 2 0 1 2 9 PE R M I T I S S U E ISSUED FOR REFERENCE ONLY ISSUED FOR CONSTRUCTION SECTION REFERENCE NUMBER. SECTION SHEET NUMBER WORK NOTE DESIGNATION. EQUIPMENT DESIGNATION. PIPE ANCHOR,ALIGNMENT GUIDE CHECK VALVE PIPE CAP, BLIND FLANGE PIPE DOWN AND PIPE TEE DOWN PIPE UP AND PIPE TEE UP PRESSURE REDUCING VALVE BALANCING VALVE ALL SYMBOLS IN LEGEND MAY NOT BE USED ON THIS PROJECT. PLUMBING LEGEND ABBREVIATIONS PIPING DESIGNATIONS AND FITTINGS COMPRESSED AIR DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER CIRCULATION DOMESTIC NON-POTBALE WATER DOMESTIC SOFT COLD WATER DOMESTIC SOFT HOT WATER EXISTING DOMESTIC WATER EXISTING SANITARY GAS PIPING ABOVE GRADE SANITARY BELOW GRADE SANITARY GREASE SANITARY SS - COMBINATION WASTE AND VENT VENT CIRCUIT VENT STORM DRAIN PIPING ABOVE GRADE STORM DRAIN PIPING BELOW GRADE OVERFLOW STORM DRAIN PIPING CA CW HW HWC NP SCW SHW G SS SS SD AD ACCESS DOOR AFF ABOVE FINISH FLOOR AP ACCESS PANEL BAS BUILDING AUTOMATION SYSTEM BOP BOTTOM OF PIPE BHP BRAKE HORSE POWER BMS BUILDING MANAGEMENT SYSTEM BTU BRITISH THERMAL UNIT CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CP CONDENSATE PUMP DN DOWN (E)EXISTING ET EXPANSION TANK EWT ENTERING WATER TEMPERATURE °F DEGREES FAHRENHEIT FLA FULL LOAD AMPS FPM FEET PER MINUTE FPS FEET PER SECOND FT FEET FM FORCED MAIN GAL GALLONS GPH GALLONS PER HOUR GPM GALLONS PER MINUTE HD HEAD HP HORSE POWER HR HOUR HZ HERTZ IN INCH I.E.INVERT ELEVATION KW KILOWATT KWH KILOWATT-HOUR LBS POUNDS LF LINEAR FEET LWT LEAVING WATER TEMPERATURE MBH 1000 BRITISH THERMAL UNITS PER HOUR MCA MINIMUM CIRCUIT AMPS MOCP MAXIMUM OVER CURRENT PROTECTION NA NOT APPLICABLE NC NORMALLY CLOSED NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NO NORMALLY OPEN NPSHA NET POSITIVE SUCTION HEAD AVAILABLE NPSHR NET POSITIVE SUCTION HEAD REQUIRED P PUMP PCF POUND PER CUBIC FOOT PD PRESSURE DROP PH PHASE PRV PRESSURE REDUCING VALVE PSI POUND PER SQUARE INCH PSIA POUND PER SQUARE INCH ABS. PSIG POUND PER SQUARE INCH GAUGE RPM REVOLUTIONS PER MINUTE SQ FT SQUARE FEET TAB TESTING AND BALANCING TDH TOTAL DEVELOPED HEAD TEL TOTAL EQUIVALENT LENGTH TYP TYPICAL UNO UNLESS NOTED OTHERWISE UV ULTRA VIOLET V VOLT VAV VARIABLE AIR VOLUME VD VOLUME DAMPER (MANUAL) VFD VARIABLE FREQUENCY DRIVE VTR VENT THRU ROOF WC WATER COLUMN WH WATER HEATER (N)NEW (E)EXISTING (F)FUTURE (R)RELOCATED WH X # ISOLATION VALVE ## @-### DEMOLITION NOTE DESIGNATION. POINT OF CONNECTION. NEW TO EXISTING EXISTING PIPING TO REMAIN EXISTING PIPING TO BE REMOVED. SYMBOLS AND DESCRIPTIONS # TWO-WAY CONTROL VALVE THREE-WAY CONTROL VALVE TEST PORT, UNION THERMOMETER, PRESSURE GAUGE WELL, MANUAL AIR VENT STRAINER PLUG VALVE X" PIPE TYPE (XXX) XXX = FIXTURE UNITS FOR WATER AND SANITARY PIPING XXX = GPM OF FLOW FOR HWC PIPING XXX = MBH CONNECTED LOAD FOR GAS PIPING XXX, XX = ROOF AREA IN SQFT. AND GPM FOR STORM PIPING PIPING NOTATION SD OSD GSS CWV V CV DYNAMIC VALVE LOCATION:ESTES PARK, CO RAINFALL RATE:3" PER HOUR CODES:2015INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2012 IECC ALL APPLICABLE LOCAL AMENDMENTS DESIGN DATA 1.DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY. WHATEVER IS CALLED FOR IN EITHER IS BINDING AS THOUGH CALLED FOR IN BOTH. 2.THE EQUIPMENT SPECIFIED ON THE DRAWINGS HAVE BEEN SELECTED AS THE BASIS OF DESIGN. THE USE OF REVIEWED OR SPECIFIED EQUALS SHALL BE COORDINATED BY THE CONTRACTOR FOR SPACE REQUIREMENTS, EQUIPMENT DIMENSIONS, AND PERFORMANCE. 3.ALL WORK SHALL CONFORM WITH ALL APPLICABLE BUILDINGS CODES, FIRE CODES, AND ALL AUTHORITIES HAVING JURISDICTION. 4.DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL DESIGN INTENT, ARRANGEMENT, AND GENERAL EXTENT OF SYSTEMS. DO NOT SCALE DRAWINGS NOR USE AS SHOP DRAWINGS. WHERE ALTERNATIVE ROUTING, OFFSETS, AND TRANSITIONS ARE REQUIRED FOR FIELD COORDINATION OF ALL OTHER TRADES, THIS CONTRACTOR SHALL PROVIDE FIELD COORDINATION OF ALL OTHER TRADES, THIS CONTRACTOR SHALL MAKE CHANGES WITHOUT ADDITIONAL COSTS. 5.CONTRACTOR SHALL CLOSELY COORDINATE NEW PLUMBING WORK WITH ALL NEW AND EXISTING MECHANICAL, PLUMBING, ELECTRICAL, FIRE PROTECTION, ARCHITECTURAL, AND STRUCTURAL MEMBERS. RELOCATE EXISTING MECHANICAL, PLUMBING AND FIRE PROTECTION WORK AS REQUIRED TO ACCOMMODATE ALL NEW WORK (ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, FIRE ALARM, LOW VOLTAGE, A/V, ETC. 6.CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION AND INSTALLING SLEEVES, INSERTS AND SUPPORTS AS REQUIRED FOR THIS SCOPE OF WORK AND/OR CORE DRILL REQUIREMENTS. COORDINATE WITH GENERAL CONTRACTOR AND STRUCTURAL ENGINEER AS REQUIRED. 7.ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION UNLESS SPECIFICALLY DIRECTED OTHERWISE. 8.THE PLUMBING DIAGRAMS SHALL BE INCORPORATED INTO THE ASSOCIATED WORK AND PROVIDE GENERAL GUIDANCE AS TO THE INSTALLATION INTENT WHETHER REFERENCED TO OR NOT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL NECESSARY COMPONENTS FOR A COMPLETE INSTALLATION, AND INSURE THAT ALL INSTALLATIONS ARE IN ACCORDANCE WITH THE EQUIPMENT'S MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. 9.CONTRACTOR SHALL VERIFY THE EXACT LOCATION AND INVERT ELEVATIONS OF ALL EXISTING UTILITIES AT THE SITE PRIOR TO THE INSTALLATION OF ANY PIPING SYSTEMS. 10.ALL SANITARY SEWER PIPING 3” AND LARGER SHALL SLOPE AT 1% OR 1/8” PER FOOT, UNLESS NOTED OTHERWISE. ALL SANITARY SEWER PIPING 2” AND SMALLER SHALL SLOPE AT 2% OR 1/4” PER FOOT. 11. ALL WALL AND FLOOR CLEAN OUTS, SERVING 4” AND SMALLER, SHALL BE THE SAME SIZE AS THE PIPING SYSTEM THEY SERVE. CLEAN OUTS SERVING 5” AND 6” PIPE SYSTEMS SHALL BE 4”. CLEAN OUTS SERVING 8” PIPING SYSTEMS SHALL BE 6”. CLEAN OUTS SERVING, 10” AND LARGER, SHALL BE 8”. 12.ALL ROOF WORK SHALL BE PER THE ROOFING MANUFACTURE'S INSTALLATION INSTRUCTIONS TO MAINTAIN THE EXISTING ROOF WARRANTY. 13.PROVIDE TEMPERING VALVES FOR ALL LAVATORIES AND HAND WASHING SINKS. TEMPERING VALVES SHALL CONFORM WITH ASSE 1070 (POWERS MODEL LFG480 OR EQUIVALENT). 14.PROVIDE WATER HAMMER ARRESTERS AT ALL QUICK CLOSING VALVES WITH ISOLATION VALVE AND WITH ACCESS OR ACCESS PANEL. 15.ALL THREADED HOSE CONNECTIONS TO DOMESTIC WATER SYSTEM SHALL HAVE AN APPROVED VACUUM BREAKER. IE: HOSE BIBS, WALL HYDRANTS, SYSTEM DRAINS, EQUIPMENT DRAINS, ETC. 16.PROVIDE ACCESS PANELS IN HARD CEILINGS AND WALLS FOR ACCESS TO ALL PLUMBING EQUIPMENT, ISOLATION VALVES, ETC. THIS SHALL INCLUDE ALL NEW AND EXISTING PLUMBING ITEMS REQUIRING ACCESS. 23.FURNISH AND INSTALL WATTS SD-2 REDUCED PRESSURE BACKFLOW PREVENTION DEVICE WITH AIR GAP DRAIN FITTING FOR ALL CARBONATORS AND SODA STATIONS. 24.FURNISH AND INSTALL WATTS SD-3 BACKFLOW PREVENTION DEVICE FOR ALL COFFEE URNS AND TEA DISPENSERS. 25.FURNISH AND INSTALL WATTS 9DM3 FOR 1/2" OR 9DM2 FOR 3/4" BACKFLOW PREVENTION DEVICE FOR ALL ICE MACHINES. 26.REFERENCE KITCHEN DRAWINGS FOR PLUMBING REQUIREMENTS. 27.WHERE PIPING IS TO BE REMOVED TO A POINT, IT SHALL BE CAPPED OFF AND PROTECTED (WHERE APPLICABLE) FOR CONNECTION TO NEW WORK. INSULATION ON EXISTING PIPING SHALL BE REPAIRED EQUAL TO NEW CONDITION. 28.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND PATCHING OF DAMAGED ARCHITECTURAL COMPONENTS TO REMAIN DURING THE REMOVAL OF THE DESIGNATED SYSTEMS. COORDINATE REPAIR WITH ARCHITECT. 29.THE LOCATION AND CONDITION OF THE EXISTING PROPERTY AND PLUMBING SYSTEMS WERE TAKEN FROM PREVIOUS CONSTRUCTION DRAWINGS, OBSERVED FIELD CONDITIONS, AND ASSUMED FIELD CONDITIONS. CERTAIN ASSUMPTIONS MAY BE MADE REGARDING EXISTING CONDITIONS BECAUSE THE ASSUMPTION MAY NOT BE VERIFIED WITHOUT DESTROYING THE EXISTING SPACE. CONTRACTOR SHALL VERIFY EXISTING SYSTEMS PRIOR TO SUBMITTING FINAL BIDS, FABRICATION, OR SUBMITTALS. PLUMBING GENERAL NOTES PIPING SYSTEM NOTES 1.ALL NEW COLD, HOT AND HOT WATER CIRC WATER PIPING SHALL BE TYPE "L" HARD DRAWN COPPER CONFIRMING TO LEAD-FREE STANDARDS WITH CAST BRONZE OR WROUGHT COPPER FITTINGS, SOLDER JOINT TYPE USING ONLY LEAD FREE SOLDER. 2.PROVIDE 1 1/2" FIBERGLASS INSULATION ON ALL HOT AND HOT WATER CIRC PIPING. CW PIPING DOES NOT REQUIRE INSULATION. 3.PIPE INSULATION SHALL BE SNAP-ON TYPE, FIBERGLASS PIPE INSULATION WITH WHITE SELF-SEALING FLAME RETARDANT VAPOR BARRIER JACKET. ALL VALVES AND FITTINGS SHALL BE INSULATED. 4.PROVIDE CALCIUM SILICATE INSERT AT ALL HANGER LOCATIONS. PROVIDE INSULATION SHIELDS AT ALL HANGERS WITH HANGERS LOCATED UNDER THE INSULATION AND NOT IN CONTACT WITH THE PIPING. 5.PROVIDE PIPE MARKERS AND FLOW ARROWS FOR ALL PIPING. 6.ALL BELOW GRADE SANITARY PIPING SHALL BE SCHEDULE 40 PVC. ABOVE GRADE SANITARY SEWER SHALL BE CAST IRON WITH NO-HUB FITTINGS. 7.ABOVE GRADE GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL WITH MALLEABLE IRON FITTINGS. BELOW GRADE GAS PIPING SHALL BE POLYETHENE PIPING WITH SOCKET FUSION FITTINGS. 8.UPON THE COMPLETION OF THE DOMESTIC WATER SUPPLY SYSTEM PIPING SHALL BE TESTED AND PROVED AIR TIGHT UNDER A WATER PRESSURE TEST NOT LESS THAN THE WORKING PRESSURE OF THE SYSTEM, OR, FOR PIPING SYSTEMS EXCLUDING PLASTIC PIPE, BY AN AIR TEST OF NOT LESS THAN 50 PSIG. PIPING SHALL HOLD PRESSURE FOR A MINIMUM ONE (1) HOUR. FLOOR SINK FLOOR DRAIN FROST PROOF WALL HYDRANT HOSE BIB CLEANOUT, WALL (WCO) CLEANOUT, FINISH FLOOR (FCO) CLEANOUT, PLUG (CO) FPWH HB SPRINKLER HEAD DOWNSPOUT (DS) ROOF DRAIN (RD), OVERFLOW ROOF DRAIN (ORD) FIXTURE SUPPORT (WALL CARRIER) P0.2 PLUMBING SCHEDULES P0.3 PLUMBING DIAGRAMS P1.1 FLOOR PLAN - PLUMBING 02 / 1 9 / 2 0 2 0 PL A N R E V I E W C O M M E N T S 1 4 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 P0.1 PL U M B I N G I N D E X , LE G E N D A N D NO T E S 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 P0.2 PL U M B I N G SC H E D U L E S 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 GAS BALL SHUT-OFF VALVE DIRT LEG FULL SIZE X 6" LONG GAS EQUIPMENT UNION GAS PIPING NOTES: 1.REFERENCE PLANS FOR LOCATION AND SIZE OF TRANSFER AIR DUCTS. CLEANOUT DETAIL END OF SERVICE LINE. 0'-10" WYE. 4" PVC. 10'-0" MIN.EXPANSION JOINT MATERIAL. CONCRETE SUPPORT PAD. PVC PIPE STUB. ADAPTER. FITTING GLEANOUT THREADED PLUG. SEE SECTION DETAIL AT RIGHT. NEENAH R-1976 OR CLEANOUT COVER & FRAME APPROVED EQUAL. BALANCE PIPING SAME AS CLEANOUT GRADE 1/8"C.I. BEND CHROME WALLCOVER AND PLUGGED TEE WITH CLEANOUT FINISHED FLOOR SCREW WALL *NOTE: LOCATE CLEANOUTS WHERE THERE IS 18" CLEARANCE AROUND. NOTICE: 1.SIZE AND PROVIDE WATER HAMMER ARRESTORS PER MANUFACTURER'S RECOMMENDATIONS. 2.TYPICAL APPLICATION FOR BOTH DOMESTIC COLD AND HOT WATER SYSTEMS. 3.WATER HAMMER ARRESTORS SHOWN ON DETAIL ARE PER MINIMUM REQUIREMENTS. CONTRACTOR SHALL VERIFY EACH INSTALLATION. 4.ADD ADDITIONAL WATER HAMMER ARRESTORS AS REQUIRED PER PLUMBING AND DRAINAGE INSTITUTE (PDI) STANDARDS OR PER MANUFACTURER'S RECOMMENDATIONS. TO FIXTURES OPTION A TO FIXTURES OPTION B TO FIXTURES OPTION C TO FIXTURES OPTION D ROOF INSULATION PLUMBING CONTRACTOR OF VENT THRU ROOF IS BY TO COORDINATE INSTALL. ROOFING CONTRACTOR. FLASHING AND COUNTERFLASHING ROOF DECK REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR A MINIMUM OF 3'-0" FROM PROPERTY LINES, 10'-0" HORIZONTALLY OR 3'-0" VERTICALLY ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKES, 1'-0" FROM ANY VERTICAL SURFACE, 5'-0" FROM PARAPETS, AND 1'-6" FROM EXPANSION JOINTS, EQUIPMENT CURBS, ETC. OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS. ANCHOR PIPE TO ROOF DECK WITH U-BOLT AROUND PIPE AND ANGLE IRON WELDED OR SCREWED TO ROOF DECK OR JOIST. MINIMUM 12" BELOW ROOF NO-HUB PIPE CONNECTORS ON CAST IRON PIPE OR BELL AND SPIGOT IF PVC. PROVIDE PIPE INCREASER IF/WHERE CODE REQUIRES A MINIMUM 3" VENT THRU ROOF CORE DRILL ROOF OR PROVIDE SLEEVE IF REQUIRED BY TYPE OF ROOF DECK. PROVIDE FIRE STOP SEAL BETWEEN PIPE AND SLEEVE OR DECK MINIMUM 12" ABOVE ROOF NORMALLY. EXTEND TO HEIGHT OF PARAPET WHEN WITHIN 10' OF PARAPET. FINISHED GRADE. PROVIDE 18"x8"x6" DEEP CLEANOUT ACCESS COVER (TYP). C.I. CLEANOUT FERRULE AND PLUG (TYP). SS PIPING. RE: PLANS FOR SIZE FLOW 3'-5"4'-7" 8'-0" 7'-0" 5' - 0 " 4' - 0 " 2' - 6 " 6" WALLS, TYP. 1'-6 1/2" 1'-6 1/2" 8" BLOCK OUT WITH KOR-N-SEAL BOOT FOR PVC INLET / OUTLET PIPING, TYP. REFER TO PLANS FOR PIPE SIZE. 4" BAFFLE WALL 10"x5" BLOCK OUT IN BAFFLE WALL 24"Ø HS-20-44 MANHOLE COVERS, TYP. 8'-0" 4'-6"2'-2" 4" 5' - 1 0 " 4' - 9 " 4' - 0 " ( 4 " P V C ) 3' - 1 1 " ( 6 " P V C ) F.L. IN 24"Ø BLOCK OUT IN LID, TYP. WATER LINE 4" PVC VENT 24"Ø HS-20-44 MANHOLE COVERS, TYP. 17" 10"x5" BLOCK OUT IN BAFFLE 4' - 4 " 8" BLOCK OUT WITH KOR-N-SEAL BOOT FOR PVC INLET / OUTLET PIPING, TYP. REFER TO PLANS FOR PIPE SIZE. 3' - 9 " ( 6 " P V C ) 3' - 1 0 " ( 4 " P V C ) PROVIDE CONCRETE SHIMS AS REQUIRED FOR A FLUSH INSTALLATION. PLAN VIEW SECTION VIEW REFER TO PLAN NOTES AND FIXTURE SCHEDULE FOR MORE INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. VERIFY ALL CONNECTION SIZES AND LOCATIONS PER MANUFACTURERS REQUIREMENTS. ADJUST TO SUIT FIELD CONDITIONS. REFER TO FLOOR PLANS FOR PIPE SIZES. PROVIDE SEISMIC STRAP OR BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. PROVIDE HEAT TRAP AND AUTOMATIC VACUUM RELIEF VALVE WHEN REQUIRED BY LOCAL AUTHORITIES. FULL SIZE DRAIN LINE TO FLOOR DRAIN WATER HEATER PRESSURE & TEMP. RELIEF VALVE ISOLATION VALVE (TYP.) UNION (TYP.) EXPANSION TANK PROVIDE SUPPORTS AS NECESSARY CHECK VALVE (TYP.) 3N.TS.GREASE INTERCEPTOR - 750 GALLONS 7N.TS.DOUBLE CLEANOUT TO GRADE 1N.TS.4N.TS.GAS APPLIANCE CONNECTION 2N.TS.VENT THROUGH ROOF DETAIL TANK WATER HEATER 5N.TS.WALL CLEANOUT DETAIL 6N.TS.WATER HAMMER ARRESTROR8N.TS. Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 P0.3 PL U M B I N G DI A G R A M S 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 UP UP B.O.H. 103 F.O.H. PREP 102 CUSTOMER RR 104 TRASH ENCLOSURE COMMON AREA 3/4" CW (7) 3/4" CW 3/4" CW (5.5)3/4" CW (1) 3/4" CW (4.5) 3/4" HW (7)3/4" HW (5.5) 3/4" HW (1) 3/4" HW (0.5)3/4" HWC (0.5) 1/2" CW 3/4" CW DWH 1 CP 1 SS-1 1 2 HAND SINK HAND SINK 3-COMP SINK PREP SINK 5 3 4 12 1314 ET 1 101 VEGGIE SINK 16 1 UP UP 2" FD-1 2" FD-1 2" FD-1 2" FS-1 2" FS-1 2" FS-1 2" FD-1 3" GSS 3" G S S 4" G S S 4" G S S 3" GSS DWH 1 SS-1 3" GSS3" GSS 2" GSS 2" GSS 4" GSS 4" COTG-1 2" FCO-1 4" SS 2" V 2" V GI 1 2" V 2" V 6 6 7 7 8 9 10 11 5 15 B.O.H. 103 CUSTOMER RR 104 TRASH ENCLOSURE COMMON AREA 101 F.O.H. PREP 102 1 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 11/6/2019 12:25:20 PM - IN T A J U I C E T E N A N T F I N I S H ES T E S P A R K , C O L O R A D O 19040 PERMIT ISSUE Revision Number Revision Date G2#: 2019075 P1.1 FL O O R P L A N - PL U M B I N G SCALE: FLOOR PLAN - PLUMBING 1/4" = 1'-0" TRUE1 P1.1 SCALE: FLOOR PLAN - PLUMBING 1/4" = 1'-0" TRUE2 P1.1 WORK NOTES:# 1.CONNECT NEW 3/4" CW TO EXISTING IN BACK OF HOUSE. PLUMBING CONTRACTOR TO FIELD VERIFY CONNECTION POINT. 2.1-1/2" GAS UP TO ROOF. REFER TO SHEET M2.1 FOR CONTINUATION. 3.3/4" HW DOWN WALL. ROUTE IN WALL TO FIXTURES AS SHOWN. 4.SET DYNAMIC BALANCING VALVE TO 0.5 GPM. 5.EXISTING RESTROOM LAV TO REMAIN. DEMO EXISTING WATER CLOSET AND ASSOCIATED SANITARY BELOW FLOOR, VENT IN CEILING AND WATER LINE IN CEILING. 6.2" V UP TO 3" VTR. 7.GREASE SANITARY VENTED USING THE COMBINATION WASTE AND VENT METHOD PER 2015 IPC, SECTION 915.2. 8.(2) 2" VENTS UP THROUGH SLAB. COMBINE INTO (1) 2" VENT AND CONTINUE UP TO 3" VTR. 9.4" SS CONTINUED. COORDINATE WITH GENERAL CONTRACTOR FOR ROUTING AND CONNECTING TO EXISTING SANITARY. 10.EXISTING FLOOR SINK SERVING 3-COMP SINK AT ADJACENT TENANT SPACE. DEMO EXISTING SANITARY AND REPLACE WITH NEW 3" GSS. 11.ROUTE DRAIN TO SERVICE SINK WITH AIR-GAP. 12.1/2" CW TO ICE MACHINE. 13.1/2" TO JUICE DISPENSER. 14.1/2" CW TO ICE CREAM STORAGE. 15.ROUTE CONDENSATE DRAINS TO FLOOR DRAIN WITH AIR-GAP. 16.ROUTE 3/4" CW & HW DOWN WALL. PROVIDE 1/2" CW & HW TO VEGGIE SINK AND HAND SINK. PROVIDE TEMPERING VALVE AT HAND SINK. 1 1 02/19/2020 Reviewed by SAFEbuilt 02/19/2020 P P S S COMMUNICATIONS SYMBOL DESCRIPTION DESCRIPTIONSYMBOL CARD READER TELECOM OUTLET: PROVIDE FLUSH MOUNT 4S JUNCTION BOX WITH 2-GANG OPENING AND MUD-RING. ROUTE (1) 3/4" CONDUIT TO ACCESSIBLE ABOVE CEILING SPACE COMPLETE WITH PULLSTRING. FUTURE CABLING BY OTHERS. INTERCOMM CLOCK OUTLET PUBLIC ADDRESS SPEAKER CEILING MOUNT PUBLIC ADDRESS SPEAKER WALL MOUNTED SPEAKER WALL MOUNTED WIRELESS ACCESS POINT TV CR WAP IC A/V SYSTEM SCREEN OUTLET BELL SPEAKER CEILING MOUNT TELECOM OUTLET COMPLETE WITH CABLING/, JACKS, CONVENTIONS AS FOLLOWS: D = DATA V = VOICE P = POINT-OF-SALE # = QUANTITY OF CABLES/RJ45 JACKS, EACH D2 V2 D1/V1 TELECOM OUTLET FLUSH FLOOR MOUNTTELECOM CABINET, FLUSH MOUNT TELECOM CABINET, SURFACE MOUNT TELECOM RACK, 2-POST, 45U, UON TELECOM RACK, 4-POST, 45U, UON C N.O.N.C. PES TC J * C VFD * * GAP #GFI * SPD SA # * * M * * NAME ONE-LINE DIAGRAM AND SCHEMATIC LEGEND SYMBOL DESCRIPTION DESCRIPTIONSYMBOL FEEDER KEY PANELBOARD DISCONNECT SWITCH DISTRIBUTION BOARD MOUNTED GROUND FAULT INTERRUPTER MEDIUM VOLTAGE BLADE SWITCH MEDIUM VOLTAGE FUSED SWITCH MEDIUM VOLTAGE SWITCH WITH OPERATOR CIRCUIT BREAKER DISTRIBUTION BOARD MOUNTED POTENTIAL TRANSFORMER CURRENT TRANSFORMER MEDIUM VOLTAGE VACUUM SWITCH STRESS RELIEF DEVICE MEDIUM VOLTAGE ELBOW CONNECTOR TRANSFORMER (LINES INDICATE SHIELDED) GROUND FUSED DISCONNECT 600 VOLTS AND UNDER SHORT CIRCUIT CURRENT KEY GENERATOR ANNUNCIATOR PANEL LOCAL DISCONNECT WITH OVERCURRENT PROTECTION FUSE DISTRIBUTION BOARD MOUNTED DRAWOUT DEVICE OVERHEAD POWER SERVICE ENTRANCE LOCAL DISCONNECT VARIABLE FREQUENCY DRIVE LOCAL CONTACTOR GENERATOR METER PUSH BUTTON START STOP PUSHBUTTON SELECTOR SWITCH (*=POSITION) CONVERTER (*=TYPE) LINE FILTER JUNCTION BOX TIMECLOCK PROTECTIVE RELAY PHOTO ELECTRIC SWITCH SURGE ARRESTOR SURGE PROTECTIVE DEVICE CONTACTS ELECTRICAL EQUIPMENT ENCLOSURE COIL TRANSFER SWITCH (*=TYPE) MOTOR STARTER (*=TYPE) LOCAL MOTOR STARTER/ COMBO (*=TYPE) FVR/NR FULL VOLTAGE REVERSE/ NON-REVERSE RV REDUCED VOLTAGE 2S TWO SPEED H HAND (ON) O OFF A AUTO ATS AUTOMATIC MTS MANUAL MCC DISTRIBUTION BOARD MOUNTED AC DC ABBREVIATIONS A ABBR. DESCRIPTION ABBR.DESCRIPTION ABBR. DESCRIPTION AMPERE EP EXPLOSION PROOF NO NORMALLY OPEN AC ALT. CURRENT OR ABOVE COUNTER NTS NOT TO SCALE AF AMPERE FRAME EPO EMERGENCY POWER OFF OC ON CENTER AIC AMPERE INTERRUPTING CAPACITY FC FOOTCANDLE (R) RELOCATED AFF ABOVE FINISHED FLOOR FLUOR FLUORESCENT (RR) REMOVE & RELOCATE AFG ABOVE FINISHED GRADE G GROUND AL ALUMINUM GC GENERAL CONTRACTOR P POLE AT AMPERE TRIP GEC GROUND ELECTRODE CONDUCTOR PB PUSH BUTTON OR PULL BOX ATS AUTOMATIC TRANSFER SWITCH GEN GENERATOR PC PLUMBING CONTRACTOR AUX AUXILIARY (F)FUTURE BJ BONDING JUMPER GFCI GROUND FAULT CIRCUIT INTERRUPTER PF POWER FACTOR C CONDUIT HID HIGH INTENSITY DISCHARGE PH/Ø PHASE HPS HIGH PRESSURE SODIUM HV HIGH VOLTAGE PNL PANEL (OR PANELBOARD) CB CIRCUIT BREAKER IG ISOLATED GROUND PRI PRIMARY CCT CIRCUIT INC INCANDESCENT PVC POLYVINYL CHLORIDE CLG CEILING ISC SHORT CIRCUIT CURRENT RCPT RECEPTACLE CMS COMBINATION MOTOR STARTER JB JUNCTION BOX RMC RIGID METALLIC CONDUIT COMM COMMUNICATION MC MECHANICAL CONTRACTOR SCH SCHEDULE CPT CONTROL POWER TRANSFORMER MCB MAIN CIRCUIT BREAKER CT CURRENT TRANSFORMER MERC MERCURY VAPOR SEC SECONDARY CU COPPER MH METAL HALIDE SPD SURGE PROTECTION DEVICE DIA DIAMETER MLO MAIN LUG ONLY SPKR SPEAKER DISC DISCONNECT (N)NEW SS STAINLESS STEEL (D) DEMOLISH & REMOVE MV MEDIUM VOLTAGE SV SOLENOID VALVE DIST DISTRIBUTION N NEUTRAL SW SWITCH EC ELECTRICAL CONTRACTOR NC NORMALLY CLOSED SWBD SWITCHBOARD EM EMERGENCY SYM SYMMETRICAL EMT ELECTRICAL METALLIC TUBING NIC NOT IN CONTRACT TCC TEMP. CONTROLS CONTRACTOR (E) EXISTING TELE TELEPHONE LV LOW VOLTAGE TR TAMPER RESISTANT TVSS TRANSIENT VOLTAGE SURGE SUPPR. UF UNDER FLOOR UG UNDERGROUND UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VA VOLT-AMPERE W WIRE OR WATT WP WEATHERPROOF XFMR TRANSFORMER GENERAL SYMBOLS SYMBOL DESCRIPTION DESCRIPTIONSYMBOL EXISTING CONDITION LINEWEIGHT NEW WORK LINEWEIGHT POINT OF CONNECTION NEW TO EXISTINGEXISTING TO BE REMOVED ACCESS DOOR/PANEL WORK NOTE DESIGNATION REVISION DESIGNATION EQUIPMENT DESIGNATION ENLARGED PLAN DRAWN ON THIS SHEET ENLARGED PLAN DESIGNATION SECTION DRAWN ON THIS SHEET SECTION DESIGNATION EXXX X EXXX X X X X X DEMOLITION WORK NOTE DESIGNATIONX LCS RC OS DS VS PS IR T SWITCHING, SENSORS & CONTROLLERS SYMBOL DESCRIPTION DESCRIPTIONSYMBOL POWER STATION TRANSFORMEROCCUPANCY SENSOR VACANCY SENSOR DAYLIGHT SENSOR INFRARED SENSOR LIGHTING CONTROL STATION ROOM CONTROLLERDIMMER SWITCH, SINGLE POLE DIMMER SWITCH, THREE POLE OCCUPANCY SWITCH, SINGLE POLE, DUAL- TECHNOLOGY, UON SWITCH, SINGLE POLE SWITCH, THREE POLE SWITCH, MANUAL MOTOR STARTER * * 3 * * 3 M * RC LIGHTING SYMBOL DESCRIPTION DESCRIPTIONSYMBOL SURFACE OR PENDANT MOUNTED LUMINAIRE WALL BRACKET LUMINAIRE RECESSED LUMINAIRE SURFACE OR PENDANT MOUNTED LUMINAIRE UPPERCASE LETTER INDICATES LUMINAIRE TYPE LOWERCASE LETTER INDICATES EQUIPMENT CONTROLLED FLOODLIGHT EMERGENCY WITH BATTERY BACKUP FLOODLIGHT EMERGENCY REMOTE HEAD SURFACE DIRECTIONAL LUMINAIRE STRIP LUMINAIRE A a EXIT LUMINAIRE, ARROW SHOWS DIRECTION, SHADING INDICATES LIGHTED FACES LIGHT TRACK # OF LUMINAIRES AS SHOWN POLE MOUNTED LUMINAIRE NUMBER OF HEADS AS INDICATED ROOM CONTROLLER # RACEWAYS SYMBOL DESCRIPTION DESCRIPTIONSYMBOL MODULAR CONNECTOR AND FLEXIBLE CABLE RACEWAY OR WIRING ASSEMBLY RUN, UNDERGROUND OR UNDERFLOOR RACEWAY OR WIRING ASSEMBLY RUN SEAL OFF FITTING SURFACE RACEWAY, DEVICES AS INDICATED CAPPED CONDUIT MULTI-OUTLET ASSEMBLY (#=ON CENTER DEVICES) HOME RUN TO PANELBOARD, CIRCUITS AS INDICATED RACEWAY OR WIRING ASSEMBLY UP RACEWAY OR WIRING ASSEMBLY DOWN BUSHED CONDUIT POWER OUTLETS SYMBOL DESCRIPTION DESCRIPTIONSYMBOL SPECIAL PURPOSE FLOOR RECEPTACLE SPECIAL PURPOSE RECEPTACLE DUPLEX FLOOR RECEPTACLE GROUND FAULT RECEPTACLE GROUND FAULT CEILING RECEPTACLE DUPLEX CEILING RECEPTACLE SPECIAL PURPOSE CEILING RECEPTACLE JUNCTION BOX FLOOR SECURITY CAMERA GROUND FAULT FLOOR RECEPTACLE DUPLEX RECEPTACLE SPLIT WIRED RECEPTACLE S J JDOUBLE DUPLEX FLOOR RECEPTACLE DOUBLE DUPLEX CEILING RECEPTACLE DOUBLE DUPLEX RECEPTACLE ISOLATED GROUND RECEPTACLE ISOLATED GROUND CEILING RECEPTACLE ISOLATED GROUND FLOOR RECEPTACLE JUNCTION BOX CEILING JUNCTION BOX J SPLIT WIRED CEILING RECEPTACLE SPLIT WIRED FLOOR RECEPTACLE DOUBLE GROUND FAULT RECEPTACLE DOUBLE GROUND FAULT CEILING RECEPTACLE DOUBLE GROUND FAULT FLOOR RECEPTACLE J T PB * TC J * C VFD * * GAP SPD M POWER DISTRIBUTION LEGEND SYMBOL DESCRIPTION DESCRIPTIONSYMBOL GROUND GENERATOR ANNUNCIATOR PANEL LOCAL DISCONNECT WITH OVERCURRENT PROTECTION OVERHEAD POWER SERVICE ENTRANCE LOCAL DISCONNECT LOCAL MOTOR STARTER/ COMBO (*=TYPE) VARIABLE FREQUENCY DRIVE LOCAL CONTACTOR METER PUSH BUTTON START STOP PUSHBUTTON JUNCTION BOX TIMECLOCK SURGE PROTECTIVE DEVICE PULL BOX PANELBOARD TRANSFORMER JUNCTION BOX FLOOR MOUNTED FVR/NR FULL VOLTAGE REVERSE/ NON-REVERSE RV REDUCED VOLTAGE 2S TWO SPEED ELECTRICAL DISTRIBUTION EQUIP. (*=TYPE) MBD MAIN DISTRIBUTION BOARD MCC MOTOR CONTROL CENTER DB DISTRIBUTION BOARD BR BUS RISER SELECTOR SWITCH (*=POSITION) H HAND (ON) O OFF A AUTO ELECTRICAL DRAWING INDEX SHEET NUMBER SHEET NAME 12 / 1 7 / 1 9 - P E R M I T S E T 12 / 1 8 / 1 9 - 1 0 0 % C D ' S 02 / 1 9 / 2 0 2 0 - P L A N R E V I E W C O M M E N T S E0.0 ELECTRICAL LEGENDS & GENERAL NOTES ● ● ● E0.1 ELECTRICAL SPECIFICATIONS ● ● ● E0.2 ELECTRICAL ONE-LINE, PANEL SCHEDULE AND COMCHECK ● ● ● ED1.0 FIRST FLOOR DEMOLITION PLAN ● ● ● E1.0 OVERALL PLAN ● ● ● E1.1 FIRST FLOOR POWER PLAN ● ● ● E1.2 FIRST FLOOR PLAN - KITCHEN EQUIPMENT ● ● ● E2.1 FIRST FLOOR LIGHTING PLAN ● ● ● E2.2 ROOF PLAN ● ● ● Grand total: 9 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 1:07:16 PM E0.0 EL E C T R I C A L LE G E N D S & GE N E R A L N O T E S IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT FOOD SERVICE COORDINATION 1. COMPLETE FOOD SERVICE EQUIPMENT LAYOUTS, ELEVATI ONS, MEP ROUGH-IN LOCATIONS, CONNECTION TYPES, EXPLANATION OF LOADS, SCHEDULES, ETC. HAS NOT BEEN PROVIDED TO THE ELECTRICAL ENGINEER TO COORDINATE THESE DRAWINGS WITH. INSTEAD, GENERAL LAYOUTS AND EQUIPMENT DATA HAVE BEEN PROVIDED. REFER TO FOOD SERVICE CONSULTANT AND/OR OWNER PROVIDED FOOD SERVICE EQUIPMENT LAYOUTS, LOCATIONS, QUANTITIES, CONNECTION TYPES AND LOCATIONS, DIMENSIONAL DATA ETC. 2. COMPLETE REFRIGERATION EQUIPMENT LAYOUTS, MEP ROUGH-IN LOCATIONS, CONNECTION TYPES, EXPLANATION OFFLOADS, SCHEDULES, ETC. HAS NOT BEEN PROVIDED TO THE ELECTRICAL ENGINEER TO COORDINATE THESE DRAWINGS WITH. INSTEAD, GENERAL LAYOUTS AND EQUIPMENT DATA HAVE BEEN PROVIDED. REFER TO REFRIGERATION CONSULTANT AND/OR OWNER PROVIDED REFRIGERATION LAYOUTS, LOCATIONS, QUANTITI ES, CONNECTION TYPES AND LOCATIONS, DIMENSIONAL DATA, ETC. 3. ELECTRICAL CIRCUITING TO FOOD SERVICE AND REFRIGERATION EQUIPMENT INCLUDED HEREIN IS SHOWN FOR BIDDING PURPOSES ONLY. VERIFY ALL ELECTRICAL LOADS AND CHARACTERISTICS WITH ACTUAL EQUIPMENT PROVIDED. COORDINATE INSTALLATION WITH OWNER/ARCHITECT. Revision Number Revision Date 02/19/2020 PART 1 -GENERAL 1. GENERAL CONDITIONS, SPECIAL REQUIREMENTS, OR GENERAL REQUIREMENTS OF THE PROJECT SPECIFICATIONS MANUAL (WHERE PROVIDED) ARE MADE PART OF THIS SPECIFICATION AND HAVE THE SAME FORCE AND EFFECT AS IF COMPLETELY REPRODUCED. 2. DEFINITIONS: THE WORD "WORK" SHALL MEAN LABOR AND ANY INCIDENTAL ITEMS OR SERVICES NECESSARY FOR THE PROPER INSTALLATION AND OPERATION OF THE COMPLETE SYSTEMS NOTED ON THESE DRAWINGS AND ASSOCIATED SPECIFICATIONS. THE WORD "PROVIDE" SHALL MEAN FURNISH, INSTALL, FEED, MAKE FINAL CONNECTIONS, COMMISSION AND LEAVE IN AN APPROVED COMPLETE OPERATING CONDITION. 3. WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE LATEST ADOPTED EDITIONS OF THE APPLICABLE NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL ENERGY CONSERVATION CODE (IECC), NFPA 110, AND ALL OTHER APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS INCLUDING AMENDMENTS. 4. OBTAIN AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS REQUIRED FOR THIS WORK. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FITTING OF MATERIAL INTO THE BUILDING AS INDICATED ON THE DRAWINGS, WITHOUT INTERFERENCE WITH OTHER WORK, AND SHALL MAKE REASONABLE MODIFICATIONS IN THE LAYOUTS NEEDED TO PREVENT CONFLICT WITH OTHER TRADES, TO PROVIDE ACCESS AND FOR THE PROPER EXECUTION OF THE WORK. 6. THE WORK SHALL BE COORDINATED WITH THE WORK OF OTHER TRADES INCLUDING CONTRACT DOCUMENTS, SHOP DRAWINGS, AND EXISTING SYSTEMS (WHERE APPLICABLE). 7. DO NOT SCALE DRAWINGS AS THEY ARE DIAGRAMMATIC AND SCHEMATIC IN NATURE. CONTRACTOR SHALL PROVIDE NECESSARY ITEMS TO COMPLETE THE WORK ACCORDING TO INDUSTRY STANDARDS. IT IS THE INTENT OF THE DRAWINGS AND SPECIFICATIONS TO CALL OUT FOR FINISHED WORK, TESTED AND READY FOR OPERATION. ARRANGEMENT OF EQUIPMENT AND ROUTING OF RACEWAYS INDICATED ON ON DRAWINGS SHALL BE ROUTED PLUMB AND AT RIGHT ANGLES TO BUILDING STRUCTURE. INSTALLATION OF SYSTEMS MAY REQUIRE MODIFICATION DUE TO UNFORESEEN CONDITIONS. 8. VERIFY ALL SIZES DIMENSIONS, AND CONDITIONS BEFORE STARTING ANY WORK. ANY DEVIATIONS OR ISSUES SHALL BE TRANSMITTED TO THE ARCHITECT FOR REVIEW. 9. CONTRACTOR SHALL SUBMIT A BID BASED ON MANUFACTURER NAMES LISTED UNLESS "OR EQUAL" IS INDICATED. SUBSTITUTION REQUESTS WILL BE REVIEWED BY THE ENGINEER PROVIDED THEY ARE SUBMITTED A MINIMUM OF SEVEN (7) BUSINESS DAYS PRIOR TO THE BID DATE. CLOSING ACCEPTABILITY OF SUBSTITUTION WILL BE SOLELY DETERMINED BY THE OWNER. 10. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. 11. EXAMINATION OF BIDDING DOCUMENTS: 1. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS CAREFULLY AND, NOT LATER THAN SEVEN (7) DAYS PRIOR TO THE DATE OF RECEIPT AND SHALL MAKE WRITTEN REQUEST TO THE ARCHITECT FOR INTERPRETATION OR CORRECTION OF ANY DISCREPANCIES, AMBIGUITY, INCONSISTENCY OR ERROR THEREIN WHICH HE MAY DISCOVER. ANY INTERPRETATION OR CORRECTION WILL BE ISSUED AS AN ADDENDUM BY THE ARCHITECT. ONLY A WRITTEN INTERPRETATION OR CORRECTION BY ADDENDUM SHALL BE BINDING, NO BIDDER SHALL RELY UPON INTERPRETATIONS OR CORRECTIONS GIVEN BY ANOTHER METHOD. IF DISCREPANCIES, AMBIGUITY, INCONSISTENCY OR ERROR ARE NOT COVERED BY ADDENDUM OR WRITTEN DIRECTIVE, CONTRACTOR SHALL INCLUDE IN HIS BID, LABOR, MATERIALS AND METHODS OF CONSTRUCTION RESULTING IN HIGHER COST. AFTER AWARD OF CONTRACT, NO ALLOWANCE OR EXTRA COMPENSATION WILL BE MADE IN BEHALF OF THE CONTRACTOR DUE TO HIS FAILURE TO MAKE THE WRITTEN REQUESTS AS DESCRIBED ABOVE. 2. THE COMPANY/CONTRACTOR SUBMITTING THE REQUEST WILL BE RESPONSIBLE FOR ITS PROMPT DELIVERY. FAILURE TO SO REQUEST CLARIFICATION OF ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. THE SIGNING OF THE CONTRACT WILL BE AS CONSIDERED AS IMPLICITLY DENOTING THAT THE CONTRACTOR HAS A THOROUGH COMPREHENSION OF THE FULL INTENT AND SCOPE OF THE W ORKING DRAWINGS AND SPECIFICATIONS. 12. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 13. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNERS ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 14. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TEST SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO THE OWNER. 15. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 16. SYSTEMS SHALL BE PROVIDED COMPLETE, OPERABLE AND READY FOR CONTINUOUS OPERATIONS. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. 17. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER NATIONALLY RECOGNIZED TESTING LABORATORIES (NRTL). 18. IN INSTANCES WHERE THE PROJECT DOES NOT INCLUDE AN ARCHITECT, THE ENGINEER SHALL RECEIVE ALL CORRESPONDENCE AS DIRECTED HEREIN. B. EXISTING CONDITIONS 1. THIS PROJECT INVOLVES CONSTRUCTION INSIDE AN EXISTING STRUCTURE. CONTRACTORS, BY SUBMITTING A BID ARE DEEMED TO BE COMPLETELY FAMILIAR WITH THE EXISTING CONDITIONS OF THE BUILDING AS IT INFLUENCES THE WORK DESCRIBED. NO CLAIMS FOR EXTRA COMPENSATION WILL BE CONSIDERED FOR EXISTING CONDITIONS VISIBLE OR REASONABLY INFERABLE FROM A CAREFUL EXAMINATION OF THE EXISTING BUILDING CONDITIONS. 2. CONTRACTOR SHALL INSPECT THE EXISTING FIELD CONDITIONS AT THE SITE AND THE CONTRACT DOCUMENTS PRIOR TO THE START OF ANY WORK TO DETERMINE WHAT EFFECT THE EXISTING CONDITIONS WILL HAVE ON THE WORK. CONTRACTOR SHALL REPORT DISCREPANCIES TO THE ARCHITECT AND INCLUDE IN HIS BID ALL COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 3. CONTRACTOR SHALL CONNECT THEIR WORK TO VARIOUS EXISTING ELECTRICAL SYSTEMS. THE NEW WORK SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM CONDITIONS. 4. CARE SHALL BE TAKEN DURING INSTALLATION OF THE NEW WORK, AS NOT TO DAMAGE OR INTERRUPT THE EXISTING BUILDING SYSTEMS AND SERVICES INSTALLED. DAMAGE TO EXISTING SYSTEMS AND EQUIPMENT CAUSED BY CONTRACTOR DURING THE INSTALLATION OF THEIR WORK SHALL BE REPAIRED AND/OR REPLACED AT THE CONTRACTORS EXPENSE TO THE SATISFACTION OF THE BUILDING OWNER. 5. SHUTDOWN OF EXISTING SYSTEMS FOR CONNECTION TO EXISTING SERVICES SHALL BE COORDINATED WITH THE OWNER. CONTRACTOR SHALL SUBMIT REQUESTS WHERE THEY AFFECT THE OPERATION OF THE BUILDING SYSTEMS AT LEAST ONE (1) WEEK IN ADVANCE OF ANY REQUIRED SHUTDOWN. THE ACTUAL SHUTDOWN PERIOD SHALL BE AS SHORT AS POSSIBLE AND AT A TIME AGREED TO BY THE OWNER. 6. DEMOLITION SHALL BE COORDINATED WITH OWNER, ARCHITECT, AND GENERAL CONTRACTOR. 7. CONTRACTOR SHALL REPORT ANY EQUIPMENT DISCREPANCIES FOUND TO THE ARCHITECT WITHIN FIVE (5) DAYS OF DISCOVERY 8. CONTRACTOR SHALL REPORT DISCREPANCIES TO THE ARCHITECT AND INCLUDE IN HIS BID ALL COSTS REQUIRED TO MAKE HIS WORK MEET THE EXISTING CONDITIONS. 9. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE THE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS AS REQUIRED TO MAINTAIN AND/OR RESTORE CONTINUITY OF SERVICE TO EXISTING CIRCUITS. 10. CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY EXISTING EQUIPMENT OR CIRCUITS THAT ARE REMAINING TO BE RECONNECTED TO NEW OR EXISTING SWITCHGEAR. PROVIDE SWITCHES RECEPTACLES, CONDUIT, WIRE, ETC., AS REQUIRED TO RESTORE CONTINUITY OF CIRCUIT(S). 11. CONTRACTOR SHALL PROVIDE NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, JUNCTION BOXES, RECEPTACLES, SWITCHES, LIGHTS, FIRE ALARM DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUIT TO SOURCE. 12. EXISTING LIGHT FIXTURES, SWITCHGEAR, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR THOSE BEING RELOCATED. C.SUBMITTALS 1. CONTRACTOR SHALL SUBMIT FIVE (5) SETS OF SHOP DRAWINGS AND TECHNICAL DATA SHEETS FOR EQUIPMENT AND MATERIALS SPECIFIED. THE ENGINEER SHALL REVIEW SHOP DRAWINGS AND TECHNICAL DATA SHEETS FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS AND ISSUE A WRITTEN ASSESSMENT TO THE OWNER PRIOR TO COMMENCEMENT OF WORK. 2. CONTRACTOR SHALL IDENTIFY ANY DEVIATIONS IN THE SHOP DRAWINGS FROM THE DESIGN DOCUMENTS. 3. SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT FOR CONSIDERATION PRIOR TO BIDDING. SUBSTITUTIONS SHALL BE PRE-APPROVED IN WRITING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING REQUIREMENTS ASSOCIATED WITH SUBSTITUTED EQUIPMENT OR MATERIALS WITH OTHER BUILDING TRADES. CONTRACTOR SHALL IDENTIFY AND ANNOTATE REVISED REQUIREMENTS PER BUILDING TRADE ON THE SHOP DRAWINGS. CONTRACTOR SHALL ALSO IDENTIFY COST DEBITS OR CREDITS IN WRITING FOR THE PROPOSED CHANGES PER BUILDING TRADE. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ENGINEERING FEES NECESSARY TO CHANGE PERMIT DOCUMENTS BASED ON ALTERNATE SUBMITTAL PACKAGES/EQUIPMENT SUBSTITUTIONS. 5. PRESENT SHOP DRAWING SUBMITTAL DATA AT ONE TIME, IN ELECTRONIC PORTABLE DOCUMENT FORMAT (.PDF) IN A NEAT AND ORDERLY MANNER. PARTIAL SUBMITTALS WILL NOT BE ACCEPTED. SUBMITTALS SHALL INCLUDE BUT NOT BE LIMITED TO LIGHTING FIXTURES, SWITCHGEAR, PANELBOARDS, WIRING DEVICES, SAFETY SWITCHES, FUSES, MOTOR CONTROLLERS, LAMPS, CONDUIT, FITTINGS, TRANSFORMERS AND LIGHTING CONTROLS. 6. CONTRACTORS FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS OR EQUIPMENT. D.DRAWINGS 1. CONTRACTOR SHALL MAINTAIN, TWO (2) SETS OF WHITE PRINTS OF DRAWINGS PERTAINING TO THE WORK. ONE (1) SET OF PRINTS SHALL BE KEPT ON SITE AND CHANGES OR DEVIATIONS FROM THE CONTRACT DRAWINGS SHALL BE CAREFULLY NOTED AS CHANGES OR DEVIATIONS ARE MADE. E.OPERATING AND MAINTENCE INSTRUCTIONS 1. CONTRACTOR SHALL PROVIDE THREE (3) COPIES OF MANUFACTURERS OPERATING AND MAINTENANCE INSTRUCTIONS FOR EACH PIECE OF EQUIPMENT AND SYSTEM. COPIES SHALL BE COMPILED IN SETS AND PLACED IN A HARD COVER THREE RING BINDER WITH INDEX PAGE AND INDEX TABS. ALL NAME TAG INFORMATION SUCH AS THE MANUFACTURER, TYPE, SIZE, CAPACITY, SERIAL NUMBER, ETC. SHALL BE INCLUDED AS PART OF THE MANUAL. 2. PROVIDE WRITTEN OPERATING INSTRUCTIONS WITH DIAGRAMS FOR ELECTRICAL EQUIPMENT. 3. OPERATING AND MAINTENANCE MANUALS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW. A.GENERAL 1. PROVIDE EQUIPMENT AS SPECIFIED AND/OR SCHEDULED AND IN ACCORDANCE WITH MANUFACTURERS PUBLISHED INSTALLATION INSTRUCTIONS. EQUIPMENT SHALL OPERATE ACCORDING TO THE MANUFACTURERS "OWNERS OPERATING AND MAINTENANCE MANUAL" TROUBLE-FREE. B.WIRE AND CABLE 1. WIRE SHALL BE COPPER, 75°C RATED FOR GENERAL USE. FOR HID FIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER MINIMUM 90°C RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30°C AMBIENT. CONDUCTOR AMPACITY SHALL DERATED FOR HIGHER AMBIENT INSTALLATIONS. C.RACEWAYS AND FITTINGS 1. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. RACEWAYS IN SLAB-ON- GRADE OR BELOW GRADE SHALL BE SCHEDULE 40 PVC, WITH PVC WRAPPED (OR EQUIVALENT PROTECTION) RIGID STEEL ELBOWS AT BENDS AND TRANSITIONS FROM BELOW TO ABOVE GRADE. EMT FITTINGS SHALL BE STEEL. CONNECTORS SHALL BE INSULATED THROAT TYPE. 2. RGS OR IMC SHALL BE USED IN ALL AREAS SUBJECT TO WEATHER OR MECHANICAL DAMAGE. 3. ALL CIRCUITING SHALL BE CONCEALED. WHERE CONCEALMENT IS IMPRACTICAL, AND WITH THE SPECIFIC APPROVAL FROM THE ARCHITECT, SURFACE RACEWAY AND OUTLETS MAY BE INSTALLED, FINISHED TO MATCH ADJACENT SURFACES. 4. METAL-CLAD (TYPE MC) CABLE MAY BE USED IN THE FOLLOWING LIMITED LOCATIONS: 1. 6'-0" MAXIMUM LIGHT FIXTURE WHIPS. 2. DEAD-END RUNS TO THE LAST WIRING DEVICE ON A CIRCUIT. 3. IN AREAS CONSIDERED "TIGHT" WITHIN MILLWORK AND CASEWORK INSTALLATIONS. 5. TYPE ENT RACEWAY IS NOT ALLOWED. 6. NON-METALLIC AND FLEXIBLE METAL CONDUITS SHALL HAVE A CODE SIZED COPPER GROUNDING CONDUCTOR. INCREASE CONDUIT SIZE AS REQUIRED. 7. WHERE MECHANICAL EQUIPMENT IS INSTALLED ABOVE A GYPSUM BOARD CEILING REQUIRING ACCESS THROUGH AN ACCESS PANEL, PROVIDE A RECEPTACLE, SWITCH, AND LIGHT IN THE CEILING SPACE AT THE ACCESS LOCATION. 8. RECESSED LIGHT FIXTURES INSTALLED IN GYPSUM BOARD OR PLASTER CEILINGS SHALL HAVE PLASTER FRAMES INSTALLED PRIOR TO THE CEILING MATERIAL. 9. MULTI-BALLSTED OR DRIVER FLUORESCENT OR LED FIXTURES SHALL BE DUAL-SWITCHED UNLESS NOTED OTHERWISE. D.DISTRIBUTION EQUIPMENT 1. SWITCHBOARDS, DISTRIBUTION BOARDS, PANELBOARDS, DISCONNECT SWITCHES, MOTOR CONTROL CENTERS, ETC. SHALL BE FURNISHED BY SQUARE D (SCHNEIDER ELECTRIC), GENERAL ELECTRIC, EATON CUTLER HAMMER, OR SIEMENS. FLOOR MOUNTED EQUIPMENT SHALL INSTALLED ATOP 4" HIGH CONCRETE HOUSEKEEPING PADS. 2. TRANSFORMERS SHALL BE COPPER WOUND, 115° RISE WITH 220°C INSULATION. MOUNT ON RUBBER-IN-SHEAR ISOLATORS. MANUFACTURERS SHALL BE SQUARE D (SCHNEIDER ELECTRIC), GENERAL ELECTRIC, EATON CUTLER HAMMER, OR SIEMENS. INSTALL ATOP 4" HIGH CONCRETE HOUSEKEEPING PAD. 3. PROVIDE ENGRAVED NAMEPLATES MECHANICALLY FASTENED WITH A MINIMUM OF TWO (2) SCREWS ON ALL SWITCHBOARDS, PANELBOARDS DISCONNECT SWITCHES, MOTOR CONTROL CENTERS, TRANSFORMERS, ETC. INDICATING EQUIPMENT DESIGNATION (OR DESIGNATION OF EQUIPMENT SERVED), VOLTAGE, AND SOURCE. EXAMPLE: "PANEL HPA, SERVED FROM SWITCHBOARD 'MSB', 480/277V, 3PH, 4W". 4. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE. FUSIBLE SWITCHES SHALL ACCEPT CLASS 'R' FUSES ONLY AND REJECT OTHERS. INSTALL DISCONNECT SWITCH ON TWO (2) 24" LONG UNITSTRUT CHANNELS DRILLED AND BOLTED TO HVAC UNIT FRAME WHERE POSSIBLE (COORDINATE LOCATION W/HVAC MANUFACTURER TO AVOID WARRANTY INFRACTIONS). SILICONE SEAL ALL HOLES IN UNIT. 5. CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE AND FUSES SHALL BE BUSSMAN OR APPROVED EQUIVALENT. CIRCUIT BREAKERS SHALL BE FULLY RATED IN EXCESS OF AVAILABLE FAULT CURRENT LEVELS. SERIES RATING OF EQUIPMENT IS PROHIBITED. 6. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT BREAKERS, SAFETY SWITCHES, AND ALL OTHER ELECTRICAL APPARATUS SHALL BE LISTED AS SUITABLE FOR 75°C. 7. ALL EQUIPMENT SUCH AS SWITCHBOARDS, DISTRIBUTION BOARDS, DISCONNECT SWITCHES, TRANSFORMERS AND PANELBOARDS SHALL BE BY THE SAME MANUFACTURER. ALL FUSES PROVIDED SHALL BE OF THE SAME MANUFACTURER. 8. PROVIDE HANDLE TIES OR MULTI-POLE CIRCUIT BREAKERS FOR SIMULTANEOUS OPERATION OF ALL MULTI-WIRE BRANCH CIRCUITS. 9. PROVIDE ARC-FLASH LABELING ON ALL DISTRIBUTION EQUIPMENT. E.WIRING DEVICES 1. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES. THE DEVICE PLATES SHALL BE LEXAN OR NYLON UNLESS OTHERWISE NOTED. THE COLOR OF THE DEVICES AND COVERPLATES SHALL BE AS DIRECTED BY THE ARCHITECT. 2. SMOKE-DETECTORS SHALL BE SELF-CONTAINED WITH AUDIBLE ALARM, UL LISTED AND COMPLY WITH NFPA STANDARD 72. INTERCONNECT DETECTORS WITHIN A DWELLING UNIT OR GUESTROOM TO SOUND A COMMON ALARM. 3. ALL 120 VOLT 15-AND 20-AMPERE RECEPTACLES LOCATED IN DWELLING UNITS, GUEST ROOMS AND SUITES, AND CHILD CARE FACILITIES SHALL BE TAMPER-RESISTANT TYPE. 4. LIGHT SWITCHES IN PUBLIC AREAS SHALL BE SPECIFICATION GRADE ROCKER TYPE, UON. LIGHT SWITCHES IN BACK OF HOUSE AREAS SHALL BE SPECIFICATION GRADE TOGGLE TYPE, UON. F.BOXES 1. FLUSH FLOOR OUTLETS SHALL BE CAST IRON, QUANTITY OF GANGS AND CONDUIT ENTRIES AS REQUIRED. PROVIDE BRASS COVERPLATE FOR THE OUTLET TYPES INDICATED. PROVIDE CARPET OR TILE FLANGE TO MATCH FLOOR FINISH. 2. BOXES SHALL BE A MINIMUM OF 4" SQUARE WITH REQUIRED EXTENSIONS AND PLASTER OR TILE RINGS. G.LIGHT FIXTURES 1. RECESSED FIXTURES INSTALLED INDOORS SHALL BE THERMALLY PROTECTED. 2. FIXTURES INDICATED AS BEING EMERGENCY SHALL BE PROVIDED WITH BATTERY POWERED INVERTER UNIT MOUNTED IN, OR ADJACENT TO, FIXTURE. PROVIDE UNIT WITH FULLY AUTOMATIC TWO-RATE CHARGER, NICKEL CADMIUM BATTERY, AC "ON" PILOT LIGHT, AND TEST SWITCH. DESIGN AND WIRE UNIT TO AUTOMATICALLY TRANSFER TO BATTERY SUPPLY UPON LOSS OF NORMAL AC POWER AND TO OPERATE ONE LAMP AT 1300 LUMENS MINIMUM FOR LINEAR LAMPS, 700 LUMENS FOR COMPACT LAMPS FOR A MINIMUM OF 90- MINUTES. LED LUMEN LEVELS VARY, AND SHALL BE AS SPECIFIED. ALL EMERGENCY LIGHTING UNITS SHALL BE CONNECTED TO AN UNSWITCHED SOURCE. IN LOCATIONS ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION, EMERGENCY LIGHTING MAY BE CONNECTED TO THE EMERGENCY LEG OF A GENERATOR POWER SYSTEM IN LIEU OF BATTERY POWER. A.GENERAL 1. FINAL CONNECTIONS AND ROUGH-IN REQUIREMENTS TO EQUIPMENT SHALL BE PER MANUFACTURERS APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED INCLUDING ALL RACEWAYS, BOXES, WIRING, WIRING DEVICES, ETC. 2. CONTRACTOR SHALL PROVIDE CONTROLS, INTERLOCKS, ACCESSORIES, ETC. AS REQUIRED FOR MOTOR CONTROL. EACH STARTER SHALL CONTAIN 120V CONTROL TRANSFORMER, LED PILOT LIGHT, AND PUSHBUTTONS OR SELECTOR SWITCH AS REQUIRED, IN ADDITION TO OTHER ITEMS (AUXILIARY CONTACTS, DOOR SWITCHES, RELAYS, ETC.) REQUIRED. REFER TO CONTROL DRAWINGS AND CONTROL DIAGRAMS FOR ADDITIONAL CONDUIT, WIRE, RELAYS, TRANSFORMERS, CONNECTIONS, ETC. REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. 3. EMPTY RACEWAY SYSTEMS SHALL HAVE A #12 PULLWIRE OR EQUAL AND SHALL BE IDENTIFIED AT JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. STUB CONDUIT OUT 6" INTO AN ACCESSIBLE AREA. CAP OPEN ENDS NOT TERMINATED IN A JUNCTION BOX. 4. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH- IN. 5. RECEPTACLES WHICH ARE SHOWN WALL MOUNTED ON THE ELECTRICAL DRAWINGS ON WALLS WHICH, ON THE ARCHITECTURAL DRAWINGS AND ELEVATIONS ARE SHOWN AS GLASS OR PARTITIONS, SHALL BE FLUSH FLOOR DUPLEX RECEPTACLES MOUNTED ADJACENT TO BASE OR WALLS. COORDINATE MOUNTING HEIGHTS AND LOCATIONS OF OUTLETS AND DEVICES WITH ARCHITECTURAL MILLWORK DRAWINGS AND INTERIOR ELEVATIONS. 6. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH ARC-FAULT, GROUND FAULT, OR DIMMED CIRCUIT. 7. PROVIDE MAINTENANCE RECEPTACLE WITHIN 25'-0" OF ALL MECHANICAL, MOTORIZED, OR REFRIGERATION EQUIPMENT. 8. WHERE MECHANICAL EQUIPMENT IS INSTALLED ABOVE A GYPSUM BOARD CEILING REQUIRING ACCESS THROUGH AN ACCESS PANEL, PROVIDE A RECEPTACLE, SWITCH, AND LIGHT IN THE CEILING SPACE AT THE ACCESS LOCATION. 9. RECESSED LIGHT FIXTURES INSTALLED IN GYPSUM BOARD OR PLASTER CEILINGS SHALL HAVE PLASTER FRAMES INSTALLED PRIOR TO THE CEILING MATERIAL. 10. MULTI-BALLSTED OR DRIVER FLUORESCENT OR LED FIXTURES SHALL BE DUAL-SWITCHED UNLESS NOTED OTHERWISE. 11. LIGHT FIXTURES RECESSED IN T-BAR CEILING SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING SYSTEM WITH A MINIMUM OF TWO (2) #12 HANGAR WIRES UP TO STRUCTURE. SECURE HANGAR WIRES TO CORNERS OF FIXTURE. CLIP FIXTURE TO GRID ON TWO (2) SIDES WITH FACTORY-FURNISHED CLIPS. FINAL CONNECTION TO FIXTURE SHALL BE MADE WITH A FLEXIBLE U.L. APPROVED ASSEMBLY. 12. CONTRACTOR SHALL REFER TO FOOD SERVICE DRAWINGS FOR EXACT LOCATIONS AND ADDITIONAL ELECTRICAL REQUIREMENTS. PROVIDE JUNCTION BOXES, RECEPTACLES, CONNECTIONS, CONDUITS (TO INCLUDE SODA AND LIQUOR DISPENSING SYSTEMS), WIRE, INTERLOCKS, CONTROLS, ETC. AS REQUIRED BY THE FOOD SERVICE EQUIPMENT SUPPLIER. 13. SEE DIVISION 23 DRAWINGS FOR LOCATION OF MECHANICAL EQUIPMENT. PROVIDE SERVICE TO AND CONNECT EQUIPMENT AS REQUIRED. PROVIDE FUSES OR HACR-TYPE CIRCUIT BREAKERS FOR AIR CONDITIONING EQUIPMENT SIZED IN ACCORDANCE WITH MANUFACTURERS NAMEPLATE. WHERE FACTORY-PROVIDED DISCONNECT SWITCHES ARE UTILIZED, THEY SHALL BE RATED TO EXCEED THE AVAILABLE FAULT CURRENT AT THE EQUIPMENT. 14. HVAC CONTROLS: PROVIDE LINE VOLTAGE WIRING, RACEWAYS, AND POWER CONNECTIONS AS REQUIRED TO ACCOMMODATE HVAC CONTROL SYSTEMS. COORDINATE REQUIREMENTS WITH TEMPERATURE CONTROL, MECHANICAL, PLUMBING, AND GENERAL CONTRACTORS PRIOR TO BID. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO COMPLY WITH THIS REQUIREMENT. LOW VOLTAGE HVAC CONTROL RACEWAY SYSTEMS SHALL BE PER THE TEMPERATURE CONTROLS CONTRACTOR. THESE DOCUMENTS DO NOT INDICATE ALL CONNECTION POINTS NECESSARY FOR A COMPLETE AND OPERABLE SYSTEM. 15. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. 16. PROVIDE DYMO-TAPE TAG PRINTED LABEL INSIDE COVER OF EACH FUSIBLE SWITCH, INDICATING SIZE AND TYPE OF FUSES PROVIDED. 17. PROVIDE TWO (2) SETS OF THREE (3) SPARE FUSES FOR EACH SIZE AND TYPE PROVIDED ON THIS PROJECT. INSTALL FUSES IN A HINGED DOOR, SHEET METAL STORAGE CABINET EQUIPPED WITH CLIPS OR CUBICLES, EACH MARKED WITH THE SIZE AND TYPE OF FUSE STORED THEREIN. PROVIDE NAMEPLATE "SPARE FUSES". INSTALL IN LOCATIONS AS DIRECTED BY OWNER. 18. PROVIDE 4" HIGH CONCRETE EQUIPMENT PADS FOR FLOOR MOUNTED EQUIPMENT SUCH AS SWITCHBOARDS, MOTOR CONTROL CENTERS, TRANSFORMERS, ETC. COORDINATE WITH DISTRIBUTION EQUIPMENT TO ENSURE ALL SWITCH AND CIRCUIT BREAKER HANDLES ARE BELOW 6'-6" TO THE HIGHEST POINT. 19. CONTRACTOR SHALL PROVIDE NEW UPDATED TYPE WRITTEN PANEL DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF THIS PROJECT. 20. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING AND/OR ROTATING EQUIPMENT SHALL BE MADE WITH SEAL-TITE FLEXIBLE FLEXIBLE CONDUIT WITH APPROVED FITTINGS (3''0" MAXIMUM LENGTH). DO NOT SECURE CONDUITS OR DEVICES TO DUCTWORK OR OTHER MECHANICAL EQUIPMENT. 21. DEVICES INSTALLED IN FIRE-RATED WALLS SHALL HAVE NELSON FSP PUTTY PADS INSTALLED TO MAINTAIN FIRE INTEGRITY -ONE PAD PER HOUR OF RATING. CONDUIT PENETRATING FIRE-RATED WALLS SHALL COMPLY WITH THE REQUIREMENTS OF U.L. SYSTEM 147A FOR SINGLE CONDUITS OR U.L. SYSTEM 322 FOR MULTIPLE CONDUITS. DEVICES INSTALLED IN SOUND-RATED WALLS SHALL HAVE NELSON FSP (STC 54) SOUND RATED PUTTY PADS INSTALLED TO MAINTAIN THE SOUND INTEGRITY OF THE WALL. 22. RECEPTACLES INSTALLED OUTSIDE, ON THE BUILDING EXTERIOR OR ROOF, IN KITCHENS OR WITHIN 6'-0" MEASURED HORIZONTALLY FROM A SINK OR DRINKING FOUNTAIN UNLESS LOCATED BELOW A COUNTER OR OTHERWISE PROTECTED SHALL BE GFCI TYPE OR PROTECTED BY A GFI CIRCUIT BREAKER. 23. COORDINATE THE LOCATION OF LIGHTING FIXTURES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. UNLESS VERIFIED IN WRITING THE REFLECTED CEILING PLAN LOCATIONS SHALL GOVERN. 24. COORDINATE THE LOCATION OF WALL MOUNTED EQUIPMENT WITH THE ARCHITECTURAL INTERIOR AND EXTERIOR ELEVATIONS. UNLESS OTHERWISE VERIFIED IN WRITING THE ARCHITECTURAL DRAWINGS SHALL GOVERN. A.GENERAL 1. CONTRACTOR SHALL PROVIDE, INSTALL, TEST, AND COMMISSION A FULLY OPERATIONAL, APPROVED, FIRE ALARM AND DETECTION SYSTEM. 2. FIRE ALARM AND DETECTION SYSTEM SHALL BE PROVIDED BY THIS CONTRACTOR, PERFORMED UNDER A DESIGN-BUILD DELIVERY METHOD. 3. FIRE ALARM AND DETECTION SYSTEM SHALL BE IN FULL COMPLIANCE WITH ALL LOCAL, STATE, FEDERAL, AND ADA REQUIREMENTS. 4. CONTRACTOR SHALL PROVIDE SUBMITTALS. SUBMITTAL REQUIREMENTS: 1. SUBMITTALS SHALL BE APPROVED BY AUTHORITIES HAVING JURISDICTION PRIOR TO SUBMITTING THEM TO THE ARCHITECT. 2. DRAWINGS SHALL BE PREPARED BY PERSONS WITH THE FOLLOWING QUALIFICATIONS: 1. TRAINED AND CERTIFIED BY MANUFACTURER IN FIRE-ALARM SYSTEM DESIGN. 2. NICET-CERTIFIED, FIRE ALARM TECHNICIAN; LEVEL III MINIMUM. 3. LICENSED OR CERTIFIED BY AUTHORITIES HAVING JURISDICTION. 3. DELEGATED-DESIGN: FOR NOTIFICATION APPLIANCES AND SMOKE AND HEAT DETECTORS, IN ADDITION TO THE SUBMITTALS LISTED ABOVE, INDICATE COMPLIANCE WITH PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA, INCLUDING ANALYSIS DATA SIGNED AND SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION. 1. DRAWINGS SHOWING THE LOCATION OF EACH NOTIFICATION APPLIANCE AND SMOKE AND HEAT DETECTOR, RATINGS OF EACH, AND INSTALLATION DETAILS AS NEEDED TO COMPLY WITH LISTING CONDITIONS OF THE DEVICE. 2. DESIGN CALCULATIONS: CALCULATE REQUIREMENTS FOR SELECTING THE SPACING AND SENSITIVITY OF DETECTION, COMPLYING WITH NFPA 72. CALCULATE SPACING AND INTENSITIES FOR STROBE SIGNALS AND SOUND-PRESSURE LEVELS FOR AUDIBLE APPLIANCES. 3. INDICATED AUDIBLE APPLIANCES REQUIRED TO PRODUCE SQUARE WAVE SIGNAL PER NFPA 72. 5. EXISTING FIRE ALARM EQUIPMENT (WHERE APPLICABLE) SHALL BE MAINTAINED AND FULLY OPERATIONAL UNTIL NEW EQUIPMENT PROVIDED UNDER THIS PROJECT HAS BEEN TESTED AND ACCEPTED. NEW COMPONENTS SHALL BE COMPATIBLE WITH, AND OPERATE AS AN EXTENSION OF, EXISTING SYSTEM. PROVIDE SYSTEM MANUFACTURERS CERTIFICATION THAT ALL COMPONENTS PROVIDED HAVE BEEN TESTED AS, AND WILL OPERATE AS, A SYSTEM. 6. WARRANTY: CONTRACTOR SHALL AGREE TO REPAIR OR REPLACE FIRE ALARM SYSTEM EQUIPMENT AND COMPONENTS THAT FAIL IN MATERIALS OR WORKMANSHIP FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. 7. COMPLY WITH NFPA 72, NFPA 101, AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION FOR INSTALLATION AND TESTING OF FIRE-ALARM EQUIPMENT. INSTALL ALL ELECTRICAL WIRING TO COMPLY WITH REQUIREMENTS IN NFPA 70 INCLUDING, BUT NOT LIMITED TO, ARTICLE 760, "FIRE ALARM SYSTEMS." B.SYSTEM DESCRIPTION 1. NONCODED, UL-CERTIFIED ADDRESSABLE SYSTEM, WITH MULTIPLEXED SIGNAL TRANSMISSION AND VOICE/STROBE EVACUATION MEETING AUDIBILITY AND INTELLIGIBLE REQUIREMENTS. 2. AUTOMATIC SENSITIVITY CONTROL OF CERTAIN SMOKE DETECTORS. 3. ALL COMPONENTS PROVIDED SHALL BE LISTED FOR USE WITH THE SELECTED SYSTEM. 4. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. C.OPERATIONAL DESCRIPTION 1. NOTE: THE FOLLOWING DESCRIPTIONS REPRESENT A MASTER LIST. NOT ALL DEVICES, SYSTEMS, AND FUNCTIONS LISTED HEREIN MAY BE REPRESENTED ON THIS PROJECT. APPLICABILITY SHALL BE DETERMINED BY QUALIFIED SYSTEM DESIGN PROFESSIONAL. 2. FIRE-ALARM SIGNAL INITIATION SHALL BE BY ONE OR MORE OF THE FOLLOWING DEVICES AND SYSTEMS: 1. MANUAL STATIONS. 2. HEAT DETECTORS. 3. FLAME DETECTORS. 4. SMOKE DETECTORS. 5. DUCT SMOKE DETECTORS. 6. AIR-SAMPLING SMOKE-DETECTION SYSTEM (VESDA). 7. CARBON MONOXIDE DETECTORS. 8. COMBUSTIBLE GAS DETECTORS. 9. AUTOMATIC SPRINKLER SYSTEM WATER FLOW. 10. PREACTION SYSTEM. 11. FIRE-EXTINGUISHING SYSTEM OPERATION. 12. FIRE STANDPIPE SYSTEM. 13. DRY SYSTEM PRESSURE FLOW SWITCH. 14. FIRE PUMP RUNNING. 3. FIRE-ALARM SIGNAL SHALL INITIATE THE FOLLOWING ACTIONS: 1. CONTINUOUSLY OPERATE ALARM NOTIFICATION APPLIANCES. 2. IDENTIFY ALARM AND SPECIFIC INITIATING DEVICE AT FIRE-ALARM CONTROL UNIT. 3. TRANSMIT AN ALARM SIGNAL TO THE REMOTE ALARM RECEIVING STATION. 4. UNLOCK ELECTRIC DOOR LOCKS IN DESIGNATED EGRESS PATHS. 5. RELEASE FIRE AND SMOKE DOORS HELD OPEN BY MAGNETIC DOOR HOLDERS. 6. ACTIVATE VOICE/ALARM COMMUNICATION SYSTEM. 7. SWITCH HEATING, VENTILATING, AND AIR-CONDITIONING EQUIPMENT CONTROLS TO FIRE-ALARM MODE. 8. ACTIVATE SMOKE-CONTROL SYSTEM (SMOKE MANAGEMENT) AT FIREFIGHTERS' SMOKE-CONTROL SYSTEM PANEL. 9. ACTIVATE STAIRWELL AND ELEVATOR-SHAFT PRESSURIZATION SYSTEMS. 10. CLOSE SMOKE DAMPERS IN AIR DUCTS OF DESIGNATED AIR-CONDITIONING DUCT SYSTEMS. 11. ACTIVATE PREACTION SYSTEM. 12. RECALL ELEVATORS TO PRIMARY OR ALTERNATE RECALL FLOORS. 13. ACTIVATE ELEVATOR POWER SHUNT TRIP. 14. ACTIVATE EMERGENCY LIGHTING CONTROL. 15. ACTIVATE EMERGENCY SHUTOFFS FOR GAS AND FUEL SUPPLIES. 16. RECORD EVENTS IN THE SYSTEM MEMORY. 17. RECORD EVENTS BY THE SYSTEM PRINTER. 18. INDICATE DEVICE IN ALARM ON THE GRAPHIC ANNUNCIATOR. 4. SUPERVISORY SIGNAL INITIATION SHALL BE BY ONE OR MORE OF THE FOLLOWING DEVICES AND ACTIONS: 1. VALVE SUPERVISORY SWITCH. 2. HIGH-OR LOW-AIR-PRESSURE SWITCH OF A DRY-PIPE OR PREACTION SPRINKLER SYSTEM. 3. ALERT AND ACTION SIGNALS OF AIR-SAMPLING DETECTOR SYSTEM. 4. ELEVATOR SHUNT-TRIP SUPERVISION. 5. FIRE PUMP RUNNING. 6. FIRE-PUMP LOSS OF POWER. 7. FIRE-PUMP POWER PHASE REVERSAL. 8. INDEPENDENT FIRE-DETECTION AND -SUPPRESSION SYSTEMS. 9. USER DISABLING OF ZONES OR INDIVIDUAL DEVICES. 10. LOSS OF COMMUNICATION WITH ANY PANEL ON THE NETWORK. 5. SYSTEM TROUBLE SIGNAL INITIATION SHALL BE BY ONE OR MORE OF THE FOLLOWING DEVICES AND ACTIONS: 1. OPEN CIRCUITS, SHORTS, AND GROUNDS IN DESIGNATED CIRCUITS. 2. OPENING, TAMPERING WITH, OR REMOVING ALARM-INITIATING AND SUPERVISORY SIGNAL-INITIATING DEVICES. 3. LOSS OF COMMUNICATION WITH ANY ADDRESSABLE SENSOR, INPUT MODULE, RELAY, CONTROL MODULE, REMOTE ANNUNCIATOR, PRINTER INTERFACE, OR ETHERNET MODULE. 4. LOSS OF PRIMARY POWER AT FIRE-ALARM CONTROL UNIT. 5. GROUND OR A SINGLE BREAK IN INTERNAL CIRCUITS OF FIRE-ALARM CONTROL UNIT. 6. ABNORMAL AC VOLTAGE AT FIRE-ALARM CONTROL UNIT. 7. BREAK IN STANDBY BATTERY CIRCUITRY. 8. FAILURE OF BATTERY CHARGING. 9. ABNORMAL POSITION OF ANY SWITCH AT FIRE-ALARM CONTROL UNIT OR ANNUNCIATOR. 10. VOICE SIGNAL AMPLIFIER FAILURE. 11. HOSE CABINET DOOR OPEN. 6. SYSTEM SUPERVISORY SIGNAL ACTIONS: 1. INITIATE NOTIFICATION APPLIANCES. 2. IDENTIFY SPECIFIC DEVICE INITIATING THE EVENT AT FIRE-ALARM CONTROL UNIT. 3. RECORD THE EVENT ON SYSTEM PRINTER. 4. AFTER A TIME DELAY OF 200 SECONDS (OR PER AHJ REQUIREMENTS), TRANSMIT A TROUBLE OR SUPERVISORY SIGNAL TO THE REMOTE ALARM RECEIVING STATION. 5. TRANSMIT SYSTEM STATUS TO BUILDING MANAGEMENT SYSTEM. 6. DISPLAY SYSTEM STATUS ON GRAPHIC ANNUNCIATOR. ELECTRICAL SPECIFICATIONS A. GENERAL PART 2 -PRODUCTS PART 3 -EXECUTION PART 4 -DESIGN BUILD FIRE ALARM AND DETECTION SYSTEM PERFORMANCE CRITERIA Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:34 PM E0.1 EL E C T R I C A L SP E C I F I C A T I O N S IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT Revision Number Revision Date 02/19/2020 M E TENANT 'D' M TENANT 'H' M TENANT 'J' M NEW TENANT 'A' (E) 200/2 (E) 200/2 (E) 200/2 (E) 200/2 TENANT 'I' M (E) 200/2 TENANT 'G2' M (E) 200/2 M (X) TENANT 'A' M TENANT 'E' M TENANT 'HOUSE' M (E) 100/2 (E) 100/2 (E) 100/2 TENANT 'F' M (E) 100/2 TENANT 'B' M (E) 100/2 (E) 800/2 E E E E X E E E E (E) METER STACK 1200A, 120/240V, 1PH/3W (E) METER STACK 800A, 120/240V, 1PH/3W 1 2 T NEUTRAL GROUND (E) UTILITY XFMR ESTIMATED 167KVA PAD MOUNTED 49,400 AIC Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:34 PM E0.2 EL E C T R I C A L ON E - L I N E , P A N E L SC H E D U L E A N D CO M C H E C K IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT 1/8" = 1'-0" SINGLE LINE DIAGRAM1 1. PROVIDE GFCI TYPE CIRCUIT BREAKER (5mA). 2. PROVIDE HANDLE LOCKING DEVICE ON CIRCUIT BREAKER IN ACCORDANCE WITH NEC 422.31(B). 3. PROVIDE GFCI TYPE CIRCUIT BREAKER (30mA). NOTES: MISC. (NEC 210.19 & 215.2) 0 VA 0.00% 0 VA WATER HEATER (NEC 210.19 & 215.2) 2250 VA 100.00% 2250 VA KITCHEN EQUIPMENT (NEC 220.56) 19185 VA 65.00% 12470 VA HEATING (NEC 220.51) 500 VA 100.00% 500 VA REMAINING MOTORS (NEC 430.24) 6150 VA 107.01% 6581 VA TOTAL AVAILABLE (AMPERES):200 LARGEST MOTOR (NEC 430.24) 10660 VA 125.00% 13325 VA SPARE CAPACITY (AMPERES):15 7 % RECEPTACLES (220.44) 3940 VA 100.00% 3940 VA NEC LOAD (AMPERES):185 LIGHTING (NEC 220.42) 1063 VA 125.00% 1329 VA LOAD TYPE CONNECTED LOAD NEC DEMAND FACTOR NEC LOAD PANELBOARD LOAD SUMMARY TOTAL AMPS BY PHASE:215 A 183 A TOTAL LOAD BY PHASE:25803 VA 21905 VA 41 42 1 RBR 1 20 A 39 720 40 1 RBC48 1 20 A 37 720 1800 38 20 A 1 BLENDER TF 101 1 ROOF TOP RECEPTACLE 1 20 A 35 180 500 36 20 A 1 WIF HEAT TRACE 3 ---- -- 33 5330 1800 34 20 A 1 BLENDER TF 101 RTU-1 2 60 A 31 5330 1600 32 20 A 1 A/V MENU SCREENS 1 ORANGE JUICER 1 20 A 29 240 1063 30 20 A 1 LIGHTING 2 (E) WATER HEATER 1 20 A 27 1500 1230 28 20 A 1 OAC 1 WATER HEATER 1 20 A 25 750 1000 26 20 A 1 EXTERIOR SIGNAGE 1 ---- -- 23 500 660 24 20 A 1 CIRCULATION POWER 1 WIC CONDENSING UNIT 2 20 A 21 500 500 22 -- -- -- 1 FREEZER LIGHTING 1 20 A 19 800 500 20 20 A 2 WIF CONDENSING UNIT 1 VJ TF 101 1 20 A 17 1500 960 18 20 A 1 POS TF 101 BOH RECEPTACLES 1 20 A 15 540 0 16 -- -- --1 CONVENIENCE RECEPTACLES 1 20 A 13 720 1725 14 20 A 2 WIF 1 1 RBC60 TF 101 1 20 A 11 720 1800 12 20 A 1 BLENDER TF 101 1 1 JD TF 101 1 20 A 9 1800 0 10 -- -- --1 1 JD TF 101 1 20 A 7 1800 1725 8 20 A 2 WIC 1 1 BLENDER TF 101 1 20 A 5 1800 1800 6 20 A 1 BLENDER TF 101 1 1 IM BOH 1 20 A 3 1500 300 4 20 A 1 WGJ TF 101 1 CONVENIENCE RECEPT TF 101/ EF-2 1 20 A 1 940 855 2 20 A 1 ICS TF 101 1 NOTES LOAD DESCRIPTION P CB CKT A (VA) B (VA) CKT CB P LOAD DESCRIPTION NOTES FEED THRU:MODIFICATIONS: VOLTAGE:120/240V 1PH 3W FED FROM:MOUNTING:FLUSH MOUNTED AIC RATING:10,000 GROUND BUS:MAINS:200 A BUS RATING:225 A NEUTRAL RATING:MAIN DEVICE TYPE:MCB MANUFACTURER AND TYPE:PANELBOARD PANELBOARD: A WORK NOTES □ 1 NEW PANEL TO BE CONNECTED TO EXISTING BREAKER. ROUTE (3) 2/0 CU AND (1) #6 CU GRD IN 3" C. 2 EXISTING PANEL 'A' TO BE DEMOLISHED. Revision Number Revision Date 02/19/2020 DN PANEL A (E) IRRIGATION PANEL (E) IRRIGATION PANEL (E) PANEL (E) HOUSE PANEL (E) METER STACK (E) SERVICE ENTRANCE (E) TELECOM CABINET 1 (E) TIME CLOCK (E) METER (E) LGT CONT. Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:34 PM E1.0 OV E R A L L P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT NOT TO SCALE OVERALL PLAN1 WORK NOTES □ 1 ROUTE FEEDER FOR NEW PANEL FROM SERVICE ENTRANCE TO PANEL 'A' ON ROOF. COORDINATE ALL WORK WITH BUILDING OWNER. Revision Number Revision Date 02/19/2020 J J J J J J J J J JJ A 1 7 8 TRASH ENCLOSURE 102 TF 101 A-13 A-13 A-13 A-13 A-13 A-1 A-1 A-1 A-15 A-15 A-15 A-15 1 TYP. OF 5 PANEL A CTR 2 2 A-1 CP 1 DWH 1 A-24 A-25 A-26 4 DWH 2 A-27 3 5 A-32 A-32 A-32 A-26 2 A-32 A-32 4 EF 1 EF 2 6 6 A-1 A-1 LC-1 3-POLE, 30 AMP ELECTRICALLY HELD LIGHTING CONTACTOR A-26 PC C FRONT SIGN Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:34 PM E1.1 FI R S T F L O O R PO W E R P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT WORK NOTES □ 1 CEILING MOUNTED DUPLEX RECEPTACLE IN ACCORDANCE WITH NEC 210-62. 2 NO NEW WORK IN THIS AREA. MAINTAIN AND PROTECT THROUGH COURSE OF CONTRUCTION. 3 CONNECT CIRCUIT TO EXISTING INSTANT HOT WATER HEATER. 4 ROUTE CIRCUIT THROUGH LIGHT CONTACTOR. CONNECT ILLUMINATED SIGNAGE. VERIFY EXACT LOCATION AND ELECTRICAL CHARACTERISTICS PRIOR TO ROUGH-IN. 5 PROVIDE RECEPTACLE FOR CONNECTION TO A/V SCREEN. VERIFY EXACT LOCATION AND MOUNTING HIEGHT WITH OWNER PRIOR TO ROUGH-IN. 6 CONNECT TO LOCAL LIGHTING CIRCUIT. 1/4" = 1'-0" FIRST FLOOR POWER PLAN1 GENERAL NOTES 1 VERIFY EXACT LOCATION OF ALL EQUIPMENT WITH OWNERS REPRESENTATIVE PRIOR TO ROUGH IN. 2 CONTRACTOR TO PROVIDE ALL RACEWAYS BACK BOXES, MUD-RINGS, J-HOOKS, ETC FOR A COMPLETE TELECOM PATHWAY SYSTEM. ALL DEVICES CABLING, EQUIPMENT, ETC BY OTHERS. NOT TO SCALE EXTERIOR LIGHTING CONTROLS2 Revision Number Revision Date 02/19/2020 F F J J J J J A 1 7 8 TRASH ENCLOSURE 102 TF 101 JD JD RBC60 VJ WGJ POSPOS WIC WIF ICS B IM 1 A-8,10 2 2 A-19 A-19 3 3 A-14,16 PANEL A OAC OJ 4 4 1 S.O S.O S.O A-36 TYP. 6 RBR RBC48 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:35 PM E1.2 FI R S T F L O O R P L A N - K I T C H E N EQ U I P M E N T IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT 1. COMPLETE FOOD SERVICE EQUIPMENT LAYOUTS, ELEVATIONS, MEP ROUGH-IN LOCATIONS, CONNECTION TYPES, EXPLANATION OF LOADS, SCHEDULES, ETC. HAS NOT BEEN PROVIDED TO THE ELECTRICAL ENGINEER TO COORDINATE THESE DRAWINGS WITH. INSTEAD, GENERAL LAYOUTS AND EQUIPMENT DATA HAVE BEEN PROVIDED. REFER TO FOOD SERVICE CONSULTANT AND/OR OWNER PROVIDED FOOD SERVICE EQUIPMENT LAYOUTS, LOCATIONS, QUANTITIES, CONNECTION TYPES AND LOCATIONS, DIMENSIONAL DATA ETC. 2. COMPLETE REFRIGERATION EQUIPMENT LAYOUTS, MEP ROUGH-IN LOCATIONS, CONNECTION TYPES, EXPLANATION OFFLOADS, SCHEDULES, ETC. HAS NOT BEEN PROVIDED TO THE ELECTRICAL ENGINEER TO COORDINATE THESE DRAWINGS WITH. INSTEAD, GENERAL LAYOUTS AND EQUIPMENT DATA HAVE BEEN PROVIDED. REFER TO REFRIGERATION CONSULTANT AND/OR OWNER PROVIDED REFRIGERATION LAYOUTS, LOCATIONS, QUANTITIES, CONNECTION TYPES AND LOCATIONS, DIMENSIONAL DATA, ETC. 3. ELECTRICAL CIRCUITING TO FOOD SERVICE AND REFRIGERATION EQUIPMENT INCLUDED HEREIN IS SHOWN FOR BIDDING PURPOSES ONLY. VERIFY ALL ELECTRICAL LOADS AND CHARACTERISTICS WITH ACTUAL EQUIPMENT PROVIDED. COORDINATE INSTALLATION WITH OWNER/ARCHITECT. EQUIPMENT SCHEDULE TAG VOLTAGE PHASE LOAD (A) PANEL CIRCUIT NUMBER WIRE/CONDUIT B 120 1 PHASE 15 A 12 (3) #12, 3/4"C B 120 1 PHASE 15 A 6 (3) #12, 3/4"C B 120 1 PHASE 15 A 5 (3) #12, 3/4"C B 120 1 PHASE 15 A 34 (3) #12, 3/4"C ICS 120 1 PHASE 5.7 A 2 (3) #12, 3/4"C RBC60 120 1 PHASE 6 A 11 (3) #12, 3/4"C JD 120 1 PHASE 15 A 7 (3) #12, 3/4"C JD 120 1 PHASE 15 A 9 (3) #12, 3/4"C WGJ 120 1 PHASE 2 A 4 (3) #12, 3/4"C VJ 120 1 PHASE 10 A 17 (3) #12, 3/4"C POS 120 1 PHASE 4 A 18 (3) #12, 3/4"C IM 120 1 PHASE 10 A 3 (3) #12, 3/4"C IM 120 1 PHASE 8.2 A 28 (3) #12, 3/4"C OJ 120 1 PHASE 2 A 29 (3) #12, 3/4"C POS 120 1 PHASE 4 A 18 (3) #12, 3/4"C B 120 1 PHASE 15 A 38 (3) #12, 3/4"C RBC48 120 1 PHASE 6 A 37 (3) #12, 3/4"C RBR 120 1 PHASE A 39 (3) #12, 3/4"C GENERAL NOTES 1 THE EQUIPMENT TAGS SHOWN HERE ARE FOR REFERENCE AND TO BE USED FOR CIRCUITING PURPOSES ONLY. SEE "FOOD SERVICE" DRAWINGS PREPARED BY OTHERS FOR ACTUAL INFORMATION AND ADDITIONAL REQUIREMENTS NOT SHOWN HERE. 2 COORDINATE EQUIPMENT LOCATION AND CONNECTION REQUIREMENTS WITH OWNER. 1. CONSULT WITH ARCHITECT/OWNER FOR ADDITIONAL INFORMATION REGARDING ELECTRICAL REQUIREMENT, INCLUDING BUT NOT LIMITED TO EXPLANATION OF SYMBOLS, LOADS AND CHARACTERISTICS, ROUGH-IN REQUIREMENTS, MOUNTING HEIGHTS, EXACT LOCATIONS, INTERCONNECTION REQUIREMENTS, ETC. 2. ALL WIRING DEVICES IN FOOD SERVICE AREAS SHALL INCLUDE BLACK FINISH WITH STAINLESS STEEL COVERPLATES. 3. ALL 120VAC 15 AND 20 AMP RECEPTACLES LOCATED IN FOOD SERVICE AREAS SHALL INCLUDE GFCI PROTECTION. RECEPTACLES WHICH ARE READILY ACCESSIBLE (HOUSEKEEPING, ETC) SHALL BE GFCI TYPE. RECEPTACLES WHICH ARE NOT CONSIDERED READILY ACCESSIBLE ( LOCATED BEHIND EQUIPMENT, ETC) SHALL INCLUDE GFCI(5mA) CLASS A CIRCUIT BREAKER AT CORRESPONDING PANELBOARD. 4. WHERE THE BRANCH CIRCUIT OVERCURRENT PROTECTION DEVICE SERVES AS THE DISCONNECTING MEANS FOR PERMANENTLY CONNECTED (HARD-WIRED) APPLIANCES RATED OVER 300VA, IT SHALL BE LOCKABLE. 5. FOR APPLIANCES SERVED BY MORE THAN ONE BRANCH CIRCUIT OR FEEDER, THE DISCONNECTING MEANS SHALL BE GROUPED AND IDENTIFIED AS THE APPLIANCE DISCONNECT. 6. PROVIDE MOISTURE SEAL-OFF ASSEMBLY WHERE POWER/CONTROL CIRCUITING ENTERS COOLER AND/OR FREEZER UNITS. 7. FOR WALK-IN COOLER AND/OR FREEZER UNITS WHICH HAVE AUXILIARY DEVICES SHIPPED LOOSE (LIGHTING, SWITCHES, HEATED DAMPERS, HEATED DOOR FRAMES, ETC), PROVIDE FIELD ASSEMBLY AS NECESSARY FOR A COMPLETE AND OPERABLE SYSTEM. 8. FOR COOLER AND/OR FREEZER UNITS WHICH INCLUDE REMOTE REFRIGERATION, PROVIDE ALL INTERCONNECTIONS AND CONTROL WIRING FOR SOLENOIDS VALVE(S), POWER WIRING, THERMOSTAT(S), DRAIN HEAT TAPE, TIME CLOCK, MOTORS, ETC AS DIRECTED BY THE FOOD SERVICE EQUIPMENT MANUFACTURER/VENDOR. 9. FINAL CONNECTION TO ALL HARDWIRED FOOD SERVICE EQUIPMENT SHALL BE MADE VIA LFNC TYPE CONDUIT. 10. VERIFY FOOD SERVICE EQUIPMENT CONNECTION TYPE WITH OWNER/ARCHITECT. 11. PROVIDE RECEPTACLE TO MATCH EQUIPMENT CORD CAP NEMA PLUG CONGIGUARATION AND AMP RATING. FOOD SERVICE COORDINATION FOOD SERVICE SYSTEM NOTES WORK NOTES □ 1 PROVIDE MOISTURE-PROOF SEAL OFF FITTING WHEN ENTERING/LEAVING COOLER AND/OR FREEZER AREAS. TYP. 2 PROVIDE (4) #14 IN (1) 3/4"C. TO LOCAL COMPRESSOR FOR THERMOSTAT CONTROL WIRING. 3 PROVIDE CIRCUIT FOR WALK IN FREEZER/COOLER INTERNAL LIGHTING. 4 LOCATE DISCONNECTING SWITCH ON WALL NEAR EQUIPMENT SERVED. PROVIDE PERMANENT NAME PLATE INDICATING LOAD SERVED AND PANEL/CIRCUIT INFORMATION. 5 POS IS PART OF A CIRCUIT. 6 PROVIDE DRAIN LINE HEAT TRACE: 120-VAC, 8 WATTS/LINEAR FOOT, SELF-REGULATING. COORDINATE INSTALLATION WITH KITCHEN EQUIPEMNT CONTRACTOR. 5 5 Revision Number Revision Date 1/4" = 1'-0" FIRST FLOOR POWER PLAN - EQUIPMENT1 02/19/2020 OS PS J A 1 7 8 TRASH ENCLOSURE 102 TF 101 BE b A-30 B b A-30 BE b A-30 B d A-30 BE d A-30 C a A-30 CE a A-30 C a A-30 C a A-30 C a A-30 C a A-30 A c A-30 A c A-30 A c A-30 A c A-30 A c A-30 A c A-30 PANEL 'A' a cb BE d A-30 X1 A-30 X1 A-30 1 2 3 4 5 6 B b A-30 A-30 5 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:35 PM E2.1 FI R S T F L O O R LI G H T I N G P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT WORK NOTES □ 1 POWER PACK FOR ON/OFF CONTROL OF FIXTURES AND INTERCONNECTION OF OCCUPANCY SENSORS, 120/277 INPUT VOLTAGE, 24VDC SECONDARY VOLTAGE. 2 DIMMING SWITCH, ON/OFF, 0-10V DIMMING, LOW VOLTAGE WIRING, PLENUM RATED, 120/277 VOLT RATED. PROVIDE LOW VOLTAGE IRING TO FIXTURE AS NECESSARY FOR A COMPLETE INSTALLATION, TYP. 3 CEILING MOUNTED OCCUPANCY SENSOR, LINE VOLTAGE, DUAL TECHNOLOGY, 360 DEGREES FOV, 120/277 VOLT RATED. 4 WALL SWITCH OCCUPANCY SENSOR, DUAL TECHNOLOGY, DIMMING, MANUAL ON DEFAULT OPERATION, 120/277 VOLT RATED. 5 ROUTE UN-SWITCHED CIRCUIT TO EMERGENCY LIGHTING. 6 DIMMING SWITCH, ON/OFF, ELV DIMMING. 120/277 VOLT RATED. LIGHT FIXTURE SCHEDULE FIXTURE DESIGNATINON DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING LAMP WATTAGE VOLTAGE NOTES A ELV DIMMABLE LED PENDANT, WHITE FINISH, 120V, 4800LM, 3000K LITHONIA PD13124 SUSPENDED LED 74.5 120 B LED PANEL, 3300LM, 4000K, 0-10V DIMMABLE LITHONIA CPANL 2X2 33 35K LAY-IN LED 28 120 BE LED PANEL, 3300LM, 4000K, 0-10V DIMMABLE,WITH BATTERY BACKUP LITHONIA CPANL 2X2 33 35K M4PS1055CP FMC BRKT LAY-IN LED 28 120 1 C 6IN ROUND LED DOWNLIGHT, 3000LM , 3500K, WHITE WITH LENS, 0-10V DIMMABLE LITHONIA LDN6 3500K 3000LM L06 WR LSS MVOLT EZ10 LAY-IN/RECESS ED LED 34.8 120 1 CE 6IN ROUND LED DOWNLIGHT, 3000LM , 3500K, WHITE WITH LENS, 0-10V DIMMABLE WITH BATTERY BACKUP LITHONIA LDN6 3500K 3000LM L06 WR LSS MVOLT EZ10 ELR LAY-IN/RECESS ED LED 34.8 120 1 D COMPACT FLUORESCENT, NON-METALLIC VAPOR PROOF, LEXAN PRISMATIC POLYCARBONATE GUARD, WHITE REFLECTOR EATON SELDWA50BKSD SURFACE LED 4 120 X1 LED EXIT SIGN, GREEN LETTERS ON WHITE BACKGROUND, WHITE DIE-CAST ALUMINUM HOUSING, WITH 90 MINUTE BATTERY BACKUP LITHONIA EDGW1G LAY-IN/RECESS ED LED 5 120 NOTE: 1. COORDINATE MOUNTING HARDWARE WITH CEILING TYPES. Revision Number Revision Date 1/4" = 1'-0" FIRST FLOOR LIGHTING PLAN1 02/19/2020 EX. EX. EX. EX. EX. F F F J RTU 1 A-31,33 CU 1 CU 2 A-20,22 A-21,23 1 1 2 3 A-35 WP PC 4 Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:35 PM E2.2 RO O F P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT GENERAL NOTES 1 THE FUSE SIZE IS NOTED AS TO BE PER MANUFACTURER RECOMMENDATION WORK NOTES □ 1 PROVIDE WEATHER PROOF, 30/2 DISCONNECT 2 PROVIDE WEATHER PROOF, 60/2 DISCONNECT. ROUTE (3) #4 CU, (1) #10 GRD IN 1-1/4" C. 3 VERIFY LOCATION OF CONDENSING UNIT PRIOR TO ROUGH-IN. 4 PROVIDE PHOTOCELL. CONNECT TO 'LC-1' Revision Number Revision Date 1/8" = 1'-0" ROOF PLAN1 02/19/2020 A 1 7 8 A Issued For SD: Plot Date: Issued For DD: Issued For Permit: Issued For Construction: Seal: 206 East 4th Street, Loveland, Colorado 80537 2/19/2020 12:55:36 PM ED1.0 FI R S T F L O O R DE M O L I T I O N P L A N IJ E S T E S P A R K L L C IN T A J U I C E T E N A N T F I N I S H 18 4 E . E L K H O R N A V E , E S T E S P A R K , C O 8 0 5 1 7 2019075 PERMIT 1/4" = 1'-0" FIRST FLOOR DEMOLITION PLAN1 DEMOLITION WORK NOTES ◊ A PROVIDE COMPLETE ELECTRICAL DEMOLITION UNLESS OTHERWISE NOTED. REMOVE EXISTING OUTLETS AND EQUIPMENT IN CONFLICT WITH NEW CONDITIONS. EXISTING CONDUITS REMOVED FROM SERVICE IN BELOW-SLAB LOCATIONS MAY BE ABANDONED. REMOVE ALL WIRE FROM ABANDONED RACEWAYS. CONTRACTOR SHALL ENSURE CONTINUITY OF EXISTING CIRCUITING PASSING THROUGH DEMOLITION AREAS. EXTEND AND/OR RELOCATE AS NECESSARY. SHIFT AND/OR RELOCATE EXISTING EQUIPMENT AS NECESSARY TO ACCOMODATE NEW WORK. Revision Number Revision Date 02/19/2020