HomeMy WebLinkAboutPLANS Garage 850 Morgan St 2024-01-29APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 01/29/2024 This installation must comply with the requirements of the 2023 National Electrical Code 2015 IECC -75% OF LAMPS SHALL BE HIGH EFFICIENCY General Notes: -Min (1) emergency escape and rescue opening req’d per bedroom -Glazing to be tempered per R308 -Min (1) programmable thermostat req’d -Smoke alarm req’d in each sleeping room -Smoke/CO alarm req’d w/in 15’ vicinity of bedroom exterior. -Fireblock/Draftstop all chases and penetrations Approved by SAFEbuilt 01/29/2024 4:03:40 PM N1102.2.11 (R402.2.11) Crawl space walls. As an alternative to insulating floors over crawl spaces, crawl space walls shall be permitted to be insulated when the crawl space is not vented to the outside. Crawl space wall insulation shall be permanently fastened to the wall and extend downward from the floor to the finished grade level and then vertically and/or horizontally for at least an additional 24 inches (610 mm). Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder in accordance with this code. All joints of the vapor retarder shall overlap by 6 inches (153 mm) and be sealed or taped. The edges of the vapor retarder shall extend not less than 6 inches (153 mm) up the stem wall and shall be attached to the stem wall. Approved by SAFEbuilt 01/29/2024 4:03:46 PM