HomeMy WebLinkAboutPLANS Kitchen Remodel 1101 Sunrise Ln 2020-06-24APPROVED by SAFEbuilt;
2015 International Codes
Subject to inspection and compliance to all
Relevant, adopted Building & Municipal
Codes
06/24/2020
General Residential Electrical Requirements
- Smoke detectors required inside and outside all
bedrooms.
- Min. one smoke detector required on each level.
- Carbon monoxide detectors required within 15' of
all bedrooms throughout home.
- All outlets less than 5'6" AFF to be tamper
resistant.
- All circuits arc-fault except bathrooms and
unfinished areas.
- Min. (2) 20A, dedicated, GFCI/AFCI protected,
small appliance, countertop circuits required in
kitchens.
- Min. (1) 20A, dedicated, GFCI protected outlet
required within 36" of all lavs.
- Garage circuits to be dedicated, 20A, and GFCI
protected.
- Laundry circuit to be 20A, GFCI protected.
- All GFCI devices must be readily accessible.
- Crawlspace lighting circuits to be GFCI protected.
- Service receptacles required within 25' of all
appliances.
This structure must comply
with the requirements of the
2017 National Electrical Code
Vent dryer to exterior
Per contact via email flue was
moved/removed prior to this
remodel 6/23/20
Reviewed by
SAFEbuilt
06/24/2020
Reviewed by
SAFEbuilt
06/24/2020