HomeMy WebLinkAboutPLANS Kitchen Remodel 1101 Sunrise Ln 2020-06-24APPROVED by SAFEbuilt; 2015 International Codes Subject to inspection and compliance to all Relevant, adopted Building & Municipal Codes 06/24/2020 General Residential Electrical Requirements - Smoke detectors required inside and outside all bedrooms. - Min. one smoke detector required on each level. - Carbon monoxide detectors required within 15' of all bedrooms throughout home. - All outlets less than 5'6" AFF to be tamper resistant. - All circuits arc-fault except bathrooms and unfinished areas. - Min. (2) 20A, dedicated, GFCI/AFCI protected, small appliance, countertop circuits required in kitchens. - Min. (1) 20A, dedicated, GFCI protected outlet required within 36" of all lavs. - Garage circuits to be dedicated, 20A, and GFCI protected. - Laundry circuit to be 20A, GFCI protected. - All GFCI devices must be readily accessible. - Crawlspace lighting circuits to be GFCI protected. - Service receptacles required within 25' of all appliances. This structure must comply with the requirements of the 2017 National Electrical Code Vent dryer to exterior Per contact via email flue was moved/removed prior to this remodel 6/23/20 Reviewed by SAFEbuilt 06/24/2020 Reviewed by SAFEbuilt 06/24/2020