Loading...
HomeMy WebLinkAboutCompliance Certificate Carriage House 333 E Wonderview Ave 2020-08-07COMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Vertical Glazing / Wall Area:21% Location:Estes Park, Colorado Climate Zone:5b Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: Stanley Carriage House 2015 Dedicated Outdoor Air System Additional Efficiency Package(s) Building Area Floor Area 1-Dining: Bar Lounge/Leisure : Nonresidential 5130 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 5130 ---30.0 0.032 0.032 NORTH Ext. Wall-North 1: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 655 20.0 0.0 0.064 0.064 Ext. Wall-North 4: Solid Concrete, 10in. Thickness, Light Density, Furring: None, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 231 ---13.0 0.062 0.090 Ext. Wall-North 3: Solid Concrete, 10in. Thickness, Light Density, Furring: None, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 19 ---0.0 0.380 0.090 Ext. Wall-North 2: Steel-Framed, 16in. o.c., [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 411 13.0 9.8 0.056 0.064 Door: Wood, Swinging, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 60 ------0.310 0.370 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 28 ------0.110 0.370 Door: Insulated Metal, Swinging, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 21 ------0.110 0.370 EAST Ext. Wall-East: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 835 20.0 0.0 0.064 0.064 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 43 ------0.310 0.450 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 43 ------0.310 0.450 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 43 ------0.310 0.450 Door: Wood, Swinging, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 60 ------0.310 0.370 Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 81 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Door: Wood, Swinging, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 60 ------0.310 0.370 Ext. Wall-East Well: Concrete Block, 10in., Partially Grouted, Cells Empty, Light Density, Furring: None, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 55 ---13.0 0.063 0.090 SOUTH Ext. Wall-South: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 1084 20.0 0.0 0.064 0.064 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 122 ------0.310 0.450 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 122 ------0.310 0.450 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 122 ------0.310 0.450 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 122 ------0.310 0.450 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 122 ------0.310 0.450 WEST Ext. Wall-West 1: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 375 20.0 0.0 0.064 0.064 Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b) 122 ------0.310 0.450 Ext. Wall-West 2: Solid Concrete, 6in. Thickness, Light Density, Furring: None, [Bldg. Use 1 - Dining: Bar Lounge/Leisure] 454 ---13.0 0.065 0.090 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 19% better than code Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 82 ofPage Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version COMcheckWeb Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable C402.4.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable C402.4.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable C402.4.2 [PR14]1 In enclosed spaces > 2,500 ft2 directly under a roof with ceiling heights >15 ft. and used as an office, lobby, atrium, concourse, corridor, storage, gymnasium/exercise center, convention center, automotive service, manufacturing, non- refrigerated warehouse, retail store, distribution/sorting area, transportation, or workshop, the following requirements apply: (a) the daylight zone under skylights is >= half the floor area; (b) the skylight area to daylight zone is >= 3 percent with a skylight VT >= 0.40; or a minimum skylight effective aperture >= 1 percent. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 83 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 84 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 85 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable C402.5.5, C403.2.4. 3 [ME58]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 86 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable C402.2.1 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable C104 [IN6]1 Installed above-grade wall insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable C104 [IN2]1 Installed roof insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 87 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C402.5 [FI55]1 Building envelope contains a continuous air barrier that has been tested and deemed to limit air leakage <= 0.40 cfm/ft2. Complies Does Not Not Observable Not Applicable C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo doors. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Stanley Carriage House 2015 08/07/20Report date: 88 ofPage