HomeMy WebLinkAboutCompliance Certificate Carriage House 333 E Wonderview Ave 2020-08-07COMcheck Software Version COMcheckWeb
Envelope Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Vertical Glazing / Wall Area:21%
Location:Estes Park, Colorado
Climate Zone:5b
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Stanley Carriage House 2015
Dedicated Outdoor Air System
Additional Efficiency Package(s)
Building Area Floor Area
1-Dining: Bar Lounge/Leisure : Nonresidential 5130
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
5130 ---30.0 0.032 0.032
NORTH
Ext. Wall-North 1: Wood-Framed, 16in. o.c., [Bldg. Use 1 -
Dining: Bar Lounge/Leisure]
655 20.0 0.0 0.064 0.064
Ext. Wall-North 4: Solid Concrete, 10in. Thickness, Light
Density, Furring: None, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
231 ---13.0 0.062 0.090
Ext. Wall-North 3: Solid Concrete, 10in. Thickness, Light
Density, Furring: None, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
19 ---0.0 0.380 0.090
Ext. Wall-North 2: Steel-Framed, 16in. o.c., [Bldg. Use 1 -
Dining: Bar Lounge/Leisure]
411 13.0 9.8 0.056 0.064
Door: Wood, Swinging, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
60 ------0.310 0.370
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
28 ------0.110 0.370
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
21 ------0.110 0.370
EAST
Ext. Wall-East: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Dining:
Bar Lounge/Leisure]
835 20.0 0.0 0.064 0.064
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
43 ------0.310 0.450
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
43 ------0.310 0.450
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
43 ------0.310 0.450
Door: Wood, Swinging, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
60 ------0.310 0.370
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
81 ofPage
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Door: Wood, Swinging, [Bldg. Use 1 - Dining: Bar
Lounge/Leisure]
60 ------0.310 0.370
Ext. Wall-East Well: Concrete Block, 10in., Partially Grouted,
Cells Empty, Light Density, Furring: None, [Bldg. Use 1 -
Dining: Bar Lounge/Leisure]
55 ---13.0 0.063 0.090
SOUTH
Ext. Wall-South: Wood-Framed, 16in. o.c., [Bldg. Use 1 - Dining:
Bar Lounge/Leisure]
1084 20.0 0.0 0.064 0.064
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
122 ------0.310 0.450
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
122 ------0.310 0.450
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
122 ------0.310 0.450
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
122 ------0.310 0.450
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
122 ------0.310 0.450
WEST
Ext. Wall-West 1: Wood-Framed, 16in. o.c., [Bldg. Use 1 -
Dining: Bar Lounge/Leisure]
375 20.0 0.0 0.064 0.064
Window: Wood Frame, Perf. Specs.: Product ID 1, SHGC 0.09,
[Bldg. Use 1 - Dining: Bar Lounge/Leisure] (b)
122 ------0.310 0.450
Ext. Wall-West 2: Solid Concrete, 6in. Thickness, Light Density,
Furring: None, [Bldg. Use 1 - Dining: Bar Lounge/Leisure]
454 ---13.0 0.065 0.090
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2015 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Envelope PASSES: Design 19% better than code
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
82 ofPage
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version COMcheckWeb
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR1]1
Plans and/or specifications provide all
information with which compliance
can be determined for the building
envelope and document where
exceptions to the standard are
claimed.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1
[PR10]1
The vertical fenestration area <= 30
percent of the gross above-grade wall
area.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1
[PR11]1
The skylight area <= 3 percent of the
gross roof area.
Complies
Does Not
Not Observable
Not Applicable
C402.4.2
[PR14]1
In enclosed spaces > 2,500 ft2
directly under a roof with ceiling
heights >15 ft. and used as an office,
lobby, atrium, concourse, corridor,
storage, gymnasium/exercise center,
convention center, automotive
service, manufacturing, non-
refrigerated warehouse, retail store,
distribution/sorting area,
transportation, or workshop, the
following requirements apply: (a) the
daylight zone under skylights is >=
half the floor area; (b) the skylight
area to daylight zone is >= 3 percent
with a skylight VT >= 0.40; or a
minimum skylight effective aperture
>= 1 percent.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
83 ofPage
Section
#
& Req.ID
Footing / Foundation Inspection Complies?Comments/Assumptions
C303.2.1
[FO6]1
Exterior insulation protected against
damage, sunlight, moisture, wind,
landscaping and equipment
maintenance activities.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
84 ofPage
Section
#
& Req.ID
Framing / Rough-In Inspection Complies?Comments/Assumptions
C303.1.3
[FR12]2
Fenestration products rated in
accordance with NFRC.
Complies
Does Not
Not Observable
Not Applicable
C303.1.3
[FR13]1
Fenestration products are certified as
to performance labels or certificates
provided.
Complies
Does Not
Not Observable
Not Applicable
C402.4.3
[FR10]1
Vertical fenestration SHGC value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.3,
C402.4.3.
4
[FR8]1
Vertical fenestration U-Factor.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.4
[FR14]2
U-factor of opaque doors associated
with the building thermal envelope
meets requirements.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.5.7
[FR17]3
Vestibules are installed on all building
entrances. Doors have self-closing
devices.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
85 ofPage
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies?Comments/Assumptions
C402.5.5,
C403.2.4.
3
[ME3]3
Stair and elevator shaft vents have
motorized dampers that automatically
close.
Complies
Does Not
Not Observable
Not Applicable
C402.5.5,
C403.2.4.
3
[ME58]3
Outdoor air and exhaust systems have
motorized dampers that automatically
shut when not in use and meet
maximum leakage rates. Check
gravity dampers where allowed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
86 ofPage
Section
#
& Req.ID
Insulation Inspection Complies?Comments/Assumptions
C303.1
[IN3]1
Roof insulation installed per
manufacturer’s instructions. Blown or
poured loose-fill insulation is installed
only where the roof slope is <=3 in
12.
Complies
Does Not
Not Observable
Not Applicable
C303.1
[IN10]2
Building envelope insulation is labeled
with R-value or insulation certificate
providing R-value and other relevant
data.
Complies
Does Not
Not Observable
Not Applicable
C303.2
[IN7]1
Above-grade wall insulation installed
per manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[IN14]2
Exterior insulation is protected from
damage with a protective material.
Verification for exposed foundation
insulation may need to occur during
Foundation Inspection.
Complies
Does Not
Not Observable
Not Applicable
C402.2.1
[IN17]3
Insulation intended to meet the roof
insulation requirements cannot be
installed on top of a suspended
ceiling. Mark this requirement
compliant if insulation is installed
accordingly.
Complies
Does Not
Not Observable
Not Applicable
C104
[IN6]1
Installed above-grade wall insulation
type and R-value consistent with
insulation specifications reported in
plans and COMcheck reports.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[IN18]3
Radiant panels and associated
components, designed for heat
transfer from the panel surfaces to the
occupants or indoor space are
insulated with a minimum of R-3.5.
Complies
Does Not
Not Observable
Not Applicable
C104
[IN2]1
Installed roof insulation type and R-
value consistent with insulation
specifications reported in plans and
COMcheck reports. For some ceiling
systems, verification may need to
occur during Framing Inspection.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.5.1.
1
[IN1]1
All sources of air leakage in the
building thermal envelope are sealed,
caulked, gasketed, weather stripped
or wrapped with moisture vapor-
permeable wrapping material to
minimize air leakage.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
87 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C402.5
[FI55]1
Building envelope contains a
continuous air barrier that has been
tested and deemed to limit air leakage
<= 0.40 cfm/ft2.
Complies
Does Not
Not Observable
Not Applicable
C402.5.6
[FI37]1
Weatherseals installed on all loading
dock cargo doors.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Stanley Carriage House 2015 08/07/20Report date:
88 ofPage