Loading...
HomeMy WebLinkAboutLETTER Supplemental Instructions Carriage House 333 E Wonderview Ave 2021-03-17 414 14th Street, Suite 300 | Denver, Colorado 80202 | 303-308-1190 | moaarch.com COLORADO | WYOMING SUPPLEMENTAL INSTRUCTIONS PROJECT: The Stanley Carriage House SUPPLEMENTAL INSTRUCTION NO.: 07 OWNER: Grand Heritage Hotel Group MOA PROJECT NO.: 19131.00 CONTRACTOR: Saunders Heath Construction DATE OF ISSUANCE: 3/17/2021 Perform the Work in accordance with the following supplemental instructions issued in accordance with the Contract Documents without change in Contract Sum or Contract Time. Prior to proceeding in accordance with these instructions, indicate acceptance of these instructions for minor change to the Work as consistent with the Contract Documents and return one copy to the Architect. DESCRIPTION: SHEET A-090 – BASEMENT LEVEL FLOOR PLAN 1. Add Keynote 124 INSTALL STEP N PULL SNPE-B, BLACK FINISH PER MANUFACTURER 2. Tag Doors 04A and 05A with Keynote 124 3. Add acoustic batt insulation to walls tagged P6-a 4. Revise room layout and add elevations, BAR B03 5. Change wall between BAR B03 and B.O.H B02A from P3 to P6-a to accommodate plumbing 6. Revise room layout and add elevation, B.O.H B02A SHEET A-100 – LEVEL 1 FLOOR PLAN 1. Add W1 window at North facade 2. Add Door 110 at North facade SHEET A-110 – BASEMENT LEVEL REFLECTED CEILING PLAN 1. Revise ceiling in B.O.H B02A to be Type G1, gypsum board ceiling SHEET A-201 – EXTERIOR ELEVATIONS 1. Add W1 window and Door 110 to North façade 2. Add trim and cornice to match other exterior doors and windows SHEET A-451 – INTERIOR ELEVATIONS - BASEMENT 1. Add detail, AXON – BASEMENT BAR 2. Add detail, INTERIOR ELEVATION – BAR – NORTH 3. Add detail, INTERIOR ELEVATION – BAR – SOUTH 4. Add detail, INTERIOR ELEVATION – B02A - NORTH SHEET A-601 – DOOR AND WINDOW SCHEDULE 1. Add Door 110 to door schedule SHEET M-002 – MECHANICAL SCHEDULES 1. Revised EF-1 CFM value. SHEET M-200 – BASEMENT MECHANICAL PLAN 1. Modified ductwork and adjusted CFM value. 414 14th Street, Suite 300 | Denver, Colorado 80202 | 303-308-1190 | moaarch.com 2. Added transfer grilles and worknote M49. SHEET E-002 – ELECTRICAL SCHEDULES 1. Added fixture type “W2” to the Luminaire Schedule. SHEET E-200 – BASEMENT LIGHTING PLAN 1. Room B02A: Revised lighting. SHEET E-300 – BASEMENT POWER PLAN 1. Room B03: Added power for Bar Dishwasher, UC Refrigerator and GFCI receptacle above counter. 2. Room B02A: Revised Power. 3. Added Work Note E25. SHEET E-502 – PANEL SCHEDULES 1. Added new circuits to Panel “LBA” for the Bar. SHEET P-002 – PLUMBING SCHEDULES 1. Added L-2 and WB-1 to Plumbing Fixture Schedule SHEET P-100 – UNDERGROUND PLUMBING PLAN 1. Added piping for new bathroom and sinks. SHEET P-200 – BASEMENT PLUMBING PLAN 1. Added piping for new bathroom and sinks. 2. Revised and added worknotes. SHEET P-501 – PLUMBING ISOMETRICS 1. Added domestic and sanitary plumbing isometrics for BAR and BOH rooms. END OF MEMO ATTACHMENTS: • ARCH SHEETS: A-090, A-100, A-110, A-201, A-451, A-601 • MECH SHEETS: M-002, M-200 • ELEC SHEETS: E-002, E-200, E-300, E-502 • PLUMB SHEETS: P-002, P-100, P-200, P-501 ARCHITECT: MOA ARCHITECTURE ACCEPTED: By: Brian M. Konczak By: SIGNED: SIGNED: DATE: MAU-1 DOAS-1 T MAU-1 DOAS-1 MAU-1 DOAS-1 UP DN UP 3 A-201 4 A-201 E 1 3 A 3 A-301 3 A-301 D 2 2 A-301 2 A-301 4 C 4 A-310 1 A-301 1 A-301 B A-451 7 A-451 4 1 2 3 A4 A-351 5 A-311 4 A-301 4 A-301 9 A-312 7 A-311 1 A-310 8 MECH CHASE ABOVE CMU BLOCK WALL BELOW MECHANICAL LOUVER; RE: WALL SECTION 33 ' - 2 " 19 ' - 1 1 " 19 ' - 1 1 " 1" / 1 ' - 0 " 1" / 1 ' - 0 " 1" / 1 ' - 0 " 1" / 1 ' - 0 " MECH ROOM B06 TI STORAGE B08 T.O. SLAB 86' - 5" T.O. SLAB 85' - 10" . 86' - 6" A-401 1 LOUNGE B02 ELECTRICAL B07 LOBBY B01 MEN'S RESTROOM B04 WOMEN'S RESTROOM B05 BAR B03 B.O.H. B02A JANITOR B01A 02 B 04 A 05 A 02A 02C 03 A 08 A 06 A 07 A 07 B MECH CONDENSER ROOM B07A ELEVATOR B10 P6 - a T.O. SLAB 87' - 0" T.O. SLAB 87' - 0" A-411 1 T.O. SLAB 85' - 10" 01B 8" C L R 9' - 10 1/8" 8' - 0 3/4" 1' - 3" CFR3CFR3 CFR3 C6-cs BOH HALL B01B 105 10 4400.1S 10 4400.1S 105 105 105 105 106 107 107 10 4400.05 MECHANICAL WELL MECHANICAL WELL 113 114 117 P6-wsci A-412 4 OPH DN 1 A-201 2 A-201 T.O. PLATFORM 106 3 3/4"5' - 8 5/8" 1' - 0 5 / 8 " 6' - 4 7 / 8 " 8' - 7 " 14 ' - 9 7 / 8 " 11 ' - 1 0 3 / 4 " 11 ' - 1 0 1 / 2 " 13 ' - 7 " 106 106 118 BLOCKOUT TO 9'-0" AFF 6' - 0"13' - 0" 45' - 5"27' - 0"23' - 6" 5 6 105 106 A-412 4 A-412 1 SIM A-411 4 A4 A-351 SIM C4 A-351 2 A-310 105 10 A-312 6 A-311 3 A-310 8 A-312 01A 11 A-313 120 120 120 123 A-356 B3 C3 A-356 ADD 1 C1 A-354 2' - 3 3/4" ADD 1 4' - 5 3/8" ADD 1 5' - 7 " 15' - 2" ADD 4 ADD 4 124 124 ASI 07 ASI 07 3' - 1 1/4" 5' - 1 1 / 4 " 1' - 6"1' - 6" 02D 2' - 9 3 / 4 " 2' - 6"5' - 3 7/8" 125 126 127 128 1292' - 7 " 1' - 3" A-451 10 11 P6-a P6 - a ASI 07 A-451 12 1' - 3" STOREFRONTS, CURTAINWALLS, WINDOWS, AND LOUVERS (PREFIXED WITH 'L') DOOR OPENING / BORROWED LIGHT SYSTEM ASSEMBLY TYPE: FLOORS, WALLS, CEILINGS, AND ROOFS FLOOR PLAN: TAG IDENTIFIERS 20 0 A 1 1 1 EQUIPMENT / ACCESSORY / MATERIAL INDENTIFIER (ALSO ON INTERIOR ELEVATIONS) 1. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF SHEATHING/OUTSIDE FACE OF FOUNDATION. 2. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND FACE OF STUD FRAMING AT NEW CONSTRUCTION AND FACE OF WALL AT EXISTING CONSTRUCTION. 3. PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, CASEWORK AND ACCESSORIES. NO EXCEPTIONS. 4. ALL INTERIOR FRAMED WALL ASSEMBLIES TO BE TYPE P3, UNO. 5. ALL INTERIOR MASONRY WALL ASSEMBLIES TO BE TYPE M8, UNO. 6. ALL INTERIOR FRAMED FURRED WALL ASSEMBLIES TO BE TYPE FR3, UNO. 7. ISOLATE PERIMETER OF NON-BEARING WALL BOARD PARTITIONS ON SLAB ON GRADE AT INTERSECTIONS WITH EXTERIOR WALL AND/OR BEARING WALLS – PROVIDE ¼”SPACE VERTICAL SLIP JOINT TRIM EDGES WITH L-TYPE EDGE TRIM AND SEAL WITH ACOUSTIC SEALANT. 8. LOCATE TYPICAL HINGE SIDE DOOR JAMB 4”FROM FINISH WALL TO EDGE OF DOOR OPENING AT HOLLOW METAL FRAMES. COORDINATE SIZE OF CASING WITH OFFSET FOR WOOD FRAMES TO ENSURE THAT STANDARD CASING CAN BE INSTALLED PRIOR TO SETTING THE FRAME. 9. MAINTAIN A MINIMUM FINISHED CLEARANCE OF 18”TO THE STRIKE SIDE JAMB ON THE PULL SIDE OF ALL PUBLIC ACCESSIBLE DOORS. 10. THEATER SOUND AND LIGHTING SYSTEMS ARE NOT A PART OF THE SCOPE OF THIS PROJECT AND SHALL BE DESIGNED BY TENANT, OR TENANTS ENGINEERS, AFTER CONSTRUCTION OF CORE AND SHELL.TENANT SHALL PROVIDE SYSTEMS COMPLIANT WITH ALL APPLICABLE CODES AND STANDARDS, INCLUDING BUT NOT LIMITED TO ASSISTIVE LISTENING DEVICES. GENERAL NOTES SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION PLAN NORTH Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 8 / 2 0 2 1 4 : 3 7 : 2 9 P M A-090 BASEMENT LEVEL FLOOR PLAN St a n l e y H o t e l C a r r i a g e H o u s e Author 05.04.2020 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS Checker 1/4" = 1'-0" BASEMENT PLAN2 SHEET SPECIFIC IDENTIFICATION OF ITEMS DIRECTLY REFERENCED TO CORRESPONDING ARCHITECTURAL SPECIFICATION SECTIONS IN THE PROJECT MANUAL. THE DECIMAL AND SUFFIX NUMBERS / LETTERS ARE NOT IDENTIFIED IN SPECIFICATIONS. REFERENCE KEYNOTES 10 4400.1S FIRE EXTINGUISHER AND CABINET ASSEMBLY - SEMI-RECESSED TYPE 10 4400.05 FIRE EXTINGUISHER AND WALL MOUNT BRACKET NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION. SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET. SHEET KEYNOTES 102 METERS AND MECHANICAL EQUIPMENT, RE: MECH, PLUMB, ELECT 105 EXPOSED CONCRETE WALL 106 RE: MEP SHEETS FOR EQUIPMENT LAYOUT 107 MECHANICAL LOUVERS; RE: MECH 108 PLUMB FOR ROUGH IN LOCATIONS 110 FIRE DEPARTMENT CONNECTION 111 PLUMBING PIPE; RE: PLUMB 113 MOP SINK 114 CENTER WALL ON GRIDLINE/COLUMN 115 FLUSH OUT FINISH SURFACE WITH EXTRA LAYER OF SHEATHING THIS SIDE 116 FLUSH OUT EXTERIOR FINISH SURFACE WITH EXTRA 1" OF INSULATION THIS SIDE 117 ALIGN TO BYPASS GYP BD ON SIDE INDICATED BY NOTE 118 AREA FLOOR DRAIN, RE: PLUMB 119 ROOF OVERFLOW DRAIN LAMBSTOUGUE, RE: PLUMB 120 CUSTOM BUILT-IN BOOKCASE. CONTRACTOR TO PROVIDE ALLOWANCE 121 LOW WALL MOUNTED LIGHTS; RE: ELEC 122 EXISTING FYPON COLUMNS BY OWNER 123 CUSTOM BUILT-IN BENCH, CONTRACTOR TO PROVIDE ALLOWANCE 124 INSTALL STEPNPULL SNPE-B, BLACK FINISH PER MANUFACTURE 125 36" UNDER COUNTER REFRIDGERATOR 126 24 UNDER COUNTER DISHWASHER 127 OVER HEAD STORAGE 128 DASH LINE INDICATES EXTENT OF WALL BELOW 129 FLIP-UP COUNTER ADD 1 REVISION DATE ADDENDUM 1 2020.07.15 ADDENDUM 4 2021.02.16 ASI 07 2021.03.17 ASI 07 DN MM MM DN 2 A-201 3 A-201 4 A-201 E 1 3 A 3 A-301 3 A-301 W5 . 5 - w s W5.5s-ws W5.5-ws W5 . 5 s - w s 8' - 8 3 / 4 " 15 ' - 1 0 1 / 4 " 16 ' - 2 " 12 ' - 4 " 12 ' - 4 " 7' - 7 " GRATE OVER AREA WELL D 2 2 A-301 2 A-301 4 C 4 A-310 1 A-301 1 A-301 MECH CHASE B A-411 5 A-411 1 C6 - c s W5.5s-wsci P6-wsci.1 ELEVATOR B10 10 6 1 A-201 GRATE OVER AREA WELL W1 W1 4' - 5 1 / 2 " 5 A-311 4 A-301 4 A-301 9 A-312 7 A-311 39 ' - 1 0 " 10 4400.05 A-354 A2 95' - 11" SHELL SPACE FOR FUTURE TENTANT DOOR STACK 110 115 116 07 6200.2DS 102 07 6200.2DS 11' - 11 1/2"18' - 0"18' - 0"18' - 0"18' - 0"11' - 11 1/2" 10 ' - 1 1 " 18 ' - 0 " 10 ' - 1 1 " 7' - 3 1/2"20' - 5 1/8" W3W5W5 1 A-310 10 3 10 4 10 2 W2 W2 100 101 10 5 DOOR STACK W3 W4 W4 P6 106 A-354 A1 07 6200.2DS 10 7 W1 2' - 8" BLOCKOUT TO 9'-8" AFF 10' - 0"10' - 10" BLOCKOUT TO 9'-8" AFF 10' - 0"2' - 8" DOOR STACK 111 8"4' - 0 " 119 W4 2 A-310 A1 A-500 10 A-312 21' - 9" P6-ws.1 38' - 5 1/2" 07 6200.2DS 10 9 W6 6 A-311 5' - 9 " 5' - 9 " 8' - 8" 3 A-310 8 A-312 A-355 B3 SEAT WALL SEAT WALL 8' - 6 3 / 4 " 11 1/2" A-355 B1 A-355 B2 11 A-313 A-356 B1 P8 121 TYP 07 6200.2DS 122 122 B4 A-500 P3 6' - 0 " C1 A-354 ADD 4 ADD 4 11 0 W1 ASI 07 ASI 07 1. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF SHEATHING/OUTSIDE FACE OF FOUNDATION. 2. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND FACE OF STUD FRAMING AT NEW CONSTRUCTION AND FACE OF WALL AT EXISTING CONSTRUCTION. 3. PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, CASEWORK AND ACCESSORIES. NO EXCEPTIONS. 4. ALL INTERIOR FRAMED WALL ASSEMBLIES TO BE TYPE P3, UNO. 5. ALL INTERIOR MASONRY WALL ASSEMBLIES TO BE TYPE M8, UNO. 6. ALL INTERIOR FRAMED FURRED WALL ASSEMBLIES TO BE TYPE FR3, UNO. 7. ISOLATE PERIMETER OF NON-BEARING WALL BOARD PARTITIONS ON SLAB ON GRADE AT INTERSECTIONS WITH EXTERIOR WALL AND/OR BEARING WALLS – PROVIDE ¼”SPACE VERTICAL SLIP JOINT TRIM EDGES WITH L-TYPE EDGE TRIM AND SEAL WITH ACOUSTIC SEALANT. 8. LOCATE TYPICAL HINGE SIDE DOOR JAMB 4”FROM FINISH WALL TO EDGE OF DOOR OPENING AT HOLLOW METAL FRAMES. COORDINATE SIZE OF CASING WITH OFFSET FOR WOOD FRAMES TO ENSURE THAT STANDARD CASING CAN BE INSTALLED PRIOR TO SETTING THE FRAME. 9. MAINTAIN A MINIMUM FINISHED CLEARANCE OF 18”TO THE STRIKE SIDE JAMB ON THE PULL SIDE OF ALL PUBLIC ACCESSIBLE DOORS. 10. THEATER SOUND AND LIGHTING SYSTEMS ARE NOT A PART OF THE SCOPE OF THIS PROJECT AND SHALL BE DESIGNED BY TENANT, OR TENANTS ENGINEERS, AFTER CONSTRUCTION OF CORE AND SHELL.TENANT SHALL PROVIDE SYSTEMS COMPLIANT WITH ALL APPLICABLE CODES AND STANDARDS, INCLUDING BUT NOT LIMITED TO ASSISTIVE LISTENING DEVICES. GENERAL NOTES SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION STOREFRONTS, CURTAINWALLS, WINDOWS, AND LOUVERS (PREFIXED WITH 'L') DOOR OPENING / BORROWED LIGHT SYSTEM ASSEMBLY TYPE: FLOORS, WALLS, CEILINGS, AND ROOFS FLOOR PLAN: TAG IDENTIFIERS 20 0 A 1 1 1 EQUIPMENT / ACCESSORY / MATERIAL INDENTIFIER (ALSO ON INTERIOR ELEVATIONS) PLAN NORTH Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 8 / 2 0 2 1 4 : 3 7 : 2 9 P M A-100 LEVEL 1 FLOOR PLAN St a n l e y H o t e l C a r r i a g e H o u s e Author 05.04.2020 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS Checker 1/4" = 1'-0" LEVEL 1 PLAN1 SHEET SPECIFIC IDENTIFICATION OF ITEMS DIRECTLY REFERENCED TO CORRESPONDING ARCHITECTURAL SPECIFICATION SECTIONS IN THE PROJECT MANUAL. THE DECIMAL AND SUFFIX NUMBERS / LETTERS ARE NOT IDENTIFIED IN SPECIFICATIONS. REFERENCE KEYNOTES 07 6200.2DS PRE-FINISHED GALVANIZED STEEL SHEET METAL - DOWNSPOUT ASSEMBLY 10 4400.05 FIRE EXTINGUISHER AND WALL MOUNT BRACKET NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION. SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET. SHEET KEYNOTES 102 METERS AND MECHANICAL EQUIPMENT, RE: MECH, PLUMB, ELECT 105 EXPOSED CONCRETE WALL 106 RE: MEP SHEETS FOR EQUIPMENT LAYOUT 107 MECHANICAL LOUVERS; RE: MECH 108 PLUMB FOR ROUGH IN LOCATIONS 110 FIRE DEPARTMENT CONNECTION 111 PLUMBING PIPE; RE: PLUMB 113 MOP SINK 114 CENTER WALL ON GRIDLINE/COLUMN 115 FLUSH OUT FINISH SURFACE WITH EXTRA LAYER OF SHEATHING THIS SIDE 116 FLUSH OUT EXTERIOR FINISH SURFACE WITH EXTRA 1" OF INSULATION THIS SIDE 117 ALIGN TO BYPASS GYP BD ON SIDE INDICATED BY NOTE 118 AREA FLOOR DRAIN, RE: PLUMB 119 ROOF OVERFLOW DRAIN LAMBSTOUGUE, RE: PLUMB 120 CUSTOM BUILT-IN BOOKCASE. CONTRACTOR TO PROVIDE ALLOWANCE 121 LOW WALL MOUNTED LIGHTS; RE: ELEC 122 EXISTING FYPON COLUMNS BY OWNER 123 CUSTOM BUILT-IN BENCH, CONTRACTOR TO PROVIDE ALLOWANCE 124 INSTALL STEPNPULL SNPE-B, BLACK FINISH PER MANUFACTURE 125 36" UNDER COUNTER REFRIDGERATOR 126 24 UNDER COUNTER DISHWASHER 127 OVER HEAD STORAGE 128 DASH LINE INDICATES EXTENT OF WALL BELOW 129 FLIP-UP COUNTER REVISION DATE ADDENDUM 4 2021.02.16 ASI 07 2021.03.17 CO J J J J E 1 3 A 3 A-301 3 A-301 D 2 2 A-301 2 A-301 4 C 4 A-310 1 A-301 1 A-301 B MEN'S RESTROOM B04 WOMEN'S RESTROOM B05 MECH ROOM B06 TI STORAGE B08 LOUNGE B02 LOBBY B01 ELECTRICAL B07 B.O.H. B02A BAR B03 JANITOR B01A PLATFORM B02B MECH CONDENSER ROOM B07A ELEVATOR B10 5 A-311 4 A-301 4 A-301 9 A-312 8'-0" G1 9'-0" G1 7 A-311 155 BOH HALL B01B 155 155 155 155 1 A-310 B1 A-500 B2 A-500 10'-8" C4 160 EQ 36' - 0"EQ 1' - 6 " 9'-6" G1 B3 A-500 6' - 4 7 / 8 " 24 ' - 0 " 7' - 0 5 / 8 " C1 A-500 9'-0" C3 9'-0" G1 9'-0" C3 TYP 10'-0" C2 161 2 A-310 10 A-312 6 A-311 3 A-310 8 A-312 11 A-313 9'-10" C3 9'-0" C3 9'-0" C3 163 08 3100.03 B4 A-500 PTI-2 PTI-2 PTI-2 PTI-2 PTI-2 161 11'-8" C3 B1 A-500 C3 A-356 ADD 1 ~ 1' - 8" C1 A-354 ~1 0 " 1' - 8 " PTI-2 166 ADD 1 ASI 06 ASI 07 1. THIS PLAN SHOWS LOCATIONS OF ITEMS IN ARCHITECTURALLY SIGNIFICANT SPACES ONLY. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL PLANS FOR ALL ITEMS NOT SHOWN. 2. CENTER SUSPENDED ACOUSTICAL CEILING GRID BOTH DIRECTIONS IN ROOMS, UNLESS SHOWN OTHERWISE. 3. CENTER ALL CEILING MOUNTED ITEMS LOCATED IN ACOUSTICAL PANELS, GYPSUM BOARD SOFFITS, AND BETWEEN OTHER CEILING MOUNTED FIXTURES, UNO. SPEAKERS, SMOKE DETECTORS AND HEAT DETECTORS MAY BE CENTERED AT ¼ POINT ON ACOUSTICAL PANELS. 4. ALL CEILING ELEVATION REFERENCES ARE RELATIVE TO FINISHED FLOOR SLAB BELOW. 5. COORDINATE LIGHTING LAYOUTS IN UTILITY/STORAGE/ELECTRICAL/IDF/MDF ROOMS WITH OVERHEAD PIPING, DUCTS, AND OTHER CEILING SUSPENDED EQUIPMENT. 6. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICES AND REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT PLACEMENT OF DEVICES WITHIN CEILING GRIDS. 7. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE. 8. NOT USED 9. EAVE VENTING TO BE COORDINATED BY THE GC. GENERAL NOTES SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION ADD 1 RECESSED LINEAR LUMINAIRE LIGHT FIXTURE PENDANT OR SURFACE LUMINAIRE LIGHT FIXTURE CEILING SYMBOLS LEGEND EMERGENCY LINEAR LUMINAIRE LIGHT FIXTURE REFER TO ENGINEERING MECHANICAL, ELECTRICAL, & FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION RECESSED DOWNLIGHT LUMINAIRE LIGHT FIXTURE PENDANT OR SURFACE STRIP OR INDUSTRIAL LUMINAIRE LIGHT FIXTURE PENDANT OR SURFACE LINEAR LUMINAIRE LIGHT FIXTURE MECHANICAL -SUPPLY DIFFUSER SURFACE DIRECTIONAL LIGHT LUMINAIRE MECHANICAL -RETURN GRILLE RECESSED WALL WASHER LUMINAIRE LIGHT FIXTURE PENDANT OR SURFACE STRIP OR INDUSTRIAL EMERGENCY LUMINAIRE LIGHT FIXTURE RECESSED DOWNLIGHT EMERGENCY LUMINAIRE LIGHT FIXTURE PENDANT OR SURFACE EMERGENCY LUMINAIRE LIGHT FIXTURE PARTIAL EMERGENCY LINEAR LUMINAIRE LIGHT FIXTURE MECHANICAL -EXHAUST AIR PLAN NORTH Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 8 / 2 0 2 1 4 : 3 7 : 3 0 P M A-110 BASEMENT LEVEL REFLECTED CEILING PLAN St a n l e y H o t e l C a r r i a g e H o u s e Author 05.04.2020 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS Checker 1/4" = 1'-0" BASEMENT1 SHEET SPECIFIC IDENTIFICATION OF ITEMS DIRECTLY REFERENCED TO CORRESPONDING ARCHITECTURAL SPECIFICATION SECTIONS IN THE PROJECT MANUAL. THE DECIMAL AND SUFFIX NUMBERS / LETTERS ARE NOT IDENTIFIED IN SPECIFICATIONS. REFERENCE KEYNOTES 08 3100.03 CEILING ACCESS DOOR NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION. SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET. SHEET KEYNOTES 155 EXPOSED STRUCTURE ABOVE 160 SLOPED CEILING. 161 FOAM-IN-PLACE INSULATION, SPEC 07 2119, EXPOSED STRUCTURE ABOVE; THICKNESS TO PROVIDE R-10CI VALUE 162 SIMULATED WOOD BEAM, RECLAIMED MATERIAL FROM DEMOLITION OF CARRIAGE HOUSE 163 DECORATIVE METAL PANEL CEILING TO CONTINUE VERTICAL ALONG THIS WALL 164 COLLECTOR HEAD TO MATCH THE STANLEY CAMPUS 165 BEADBOARD SOFFIT TO MATCH STANLEY CAMPUS 166 EXTENTS OF INSULATION - RE: DETAIL C1/A-354 ADD 1 REVISION DATE ADDENDUM 1 2020.07.15 ASI 06 2021.02.23 ASI 07 2021.03.17 LEVEL 1 100' -0" 1 BASEMENT 87' -0" 3 E1 B.O. (E) TRUSS 112' -1" MECHANICAL WELL MECHANICAL LOUVER; RE: MECH 2 4 1 A-301 1 A-301 MECHANICAL WELL MECHANICAL LOUVER; RE: MECH W1W1 R1 5 A-311 4 A-301 METAL GRATE; RE: STRUCT METAL GRATE; RE: STRUCT 7 A-311 WS 07 6200.2G PRE-FINISHED GALVANIZED STEEL SHEET METAL -GUTTER ASSEMBLY 07 6200.2DS PRE-FINISHED GALVANIZED STEEL SHEET METAL -DOWNSPOUT ASSEMBLY B.O. (E) PLATE 111' -9" 101 100 6 A-311 8 A-312 206 206 W1 A-320 B2 212 WOOD BOARD SIDING WOOD BOARD SIDING ADD 1 LEVEL 1 100' -0" E BASEMENT 87' -0" A B.O. (E) TRUSS 112' -1" 3 A-301 3 A-301 WOOD MOULDING, TYP AT DOORS AND WINDOWS D 2 A-301 2 A-301 C B WOOD CORNICE, TYP R1 WS 07 6200.2G PRE-FINISHED GALVANIZED STEEL SHEET METAL -GUTTER ASSEMBLY W3 W5 1 A-310 B.O. (E) PLATE 111' -9" 103 102104 W4 W4 W5 W3 205 210 2 A-310 212 ADD 4 ADD 4 LEVEL 1 100' -0" E BASEMENT 87' -0" A B.O. (E) TRUSS 112' -1" 3 A-301 3 A-301 D 2 A-301 2 A-301 EXTERIOR STAIR WELL C 4 A-310 B R1 STRUCTURAL POSTS, TYPICAL, RE: STRUCT 9 A-312 02B 07 6200.2G PRE-FINISHED GALVANIZED STEEL SHEET METAL -GUTTER ASSEMBLY 07 6200.2DS PRE-FINISHED GALVANIZED STEEL SHEET METAL -DOWNSPOUT ASSEMBLY WSWSWS WS 07 6200.2DS PRE-FINISHED GALVANIZED STEEL SHEET METAL -DOWNSPOUT ASSEMBLY B.O. (E) PLATE 111' -9" 105 FUTURE KNOCKOUT A-320 A1 10 A-312 106 07 6200.2DS PRE-FINISHED GALVANIZED STEEL SHEET METAL -DOWNSPOUT ASSEMBLY R1 210 ADD 1 110 W1 LEVEL 1 100' -0" 1 BASEMENT 87' -0" 3 B.O. (E) TRUSS 112' -1" 24 1 A-301 1 A-301 4 A-301 R1 WS WS 07 6200.2G PRE-FINISHED GALVANIZED STEEL SHEET METAL -GUTTER ASSEMBLY W2W2 B.O. (E) PLATE 111' -9" R1 203 205 A-320 B2 3 A-310 W4 W4 WALL CLADDING LEGEND WS -WOOD SIDING -1/2" X 6" WOOD BEVEL SIDING, PTE-1 PAINTWS Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 8 / 2 0 2 1 4 : 3 7 : 3 5 P M A-201 EXTERIOR ELEVATIONS St a n l e y H o t e l C a r r i a g e H o u s e Author 05.04.2020 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS Checker 1/8" = 1'-0" EAST ELEVATION4 1/8" = 1'-0" SOUTH ELEVATION1 1/8" = 1'-0" NORTH ELEVATION3 1/8" = 1'-0" WEST ELEVATION2 SHEET SPECIFIC IDENTIFICATION OF ITEMS DIRECTLY REFERENCED TO CORRESPONDING ARCHITECTURAL SPECIFICATION SECTIONS IN THE PROJECT MANUAL. THE DECIMAL AND SUFFIX NUMBERS / LETTERS ARE NOT IDENTIFIED IN SPECIFICATIONS. REFERENCE KEYNOTES 07 6200.2DS PRE-FINISHED GALVANIZED STEEL SHEET METAL - DOWNSPOUT ASSEMBLY 07 6200.2G PRE-FINISHED GALVANIZED STEEL SHEET METAL - GUTTER ASSEMBLY NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION. SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET. SHEET KEYNOTES 203 ROOF OVERFLOW DRAIN LAMBSTOUGUE, RE: PLUMB 205 EXTERIOR LIGHTING; RE: ELEC 206 GAS METER 210 CONCRETE SEAT WALL, RE: CIVIL 212 EXISTING FYPON COLUMNS BY OWNER REVISION DATE ADDENDUM 1 2020.07.15 ADDENDUM 4 2021.02.16 ASI 07 2021.03.17 ASI 07 01B RB-1 B1 A-500 CUSTOM BUILT-IN BOOKCASE. CONTRACT OR TO PROVIDE ALLOWANCE RB-1 10 4400.1S FIRE EXTINGUISHER AND CABINET ASSEMBLY - SEMI-RECESSED TYPE EXPOSED CONCRETE WALL 03A04A05A RB-1 CUSTOM BUILT-IN BOOKCASE. CONTRACTOR TO PROVIDE ALLOWANCE NOTE: REFER TO DOOR AND WINDOW SCHEDULE FOR DOOR PANEL DESIGN 02A CUSTOM BUILT-IN BOOKCASE. CONTRACT OR TO PROVIDE ALLOWANCE CUSTOM BUILT-IN BOOKCASE. CONTRACT OR TO PROVIDE ALLOWANCE B3 A-500 02A 02C10 4400.1S FIRE EXTINGUISHER AND CABINET ASSEMBLY - SEMI-RECESSED TYPE RB-1 238 239 PTI-1 C4 A-351 ADD 1 02B RB-1 TIERED RAISERS 238 239 239 RB-1 A3 A-413 PLATFORM BEYOND B2 A-500 B2 A-413 RB-1 238 COVE LIGHTING BEYOND; RE: ELEC 239 PTI-1 P3 3' - 6 " UNDER COUNTER DISHWASHER UNDER COUNTER FRIDGE 2' - 3 7/8"5' - 6" FLIP UP COUNTER HANDSINK 3 COMPARTMENT SINK OVER HEAD STORAGE MIRROR VANITY LIGHT 3' - 0 " SOLID SURFACE COUNTERTOP - PAPERSTONE "GUNMETAL" INSULATE SUPPLY AND DRAIN LINES AT LAV 5" Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 8 / 2 0 2 1 4 : 3 7 : 3 8 P M A-451 INTERIOR ELEVATIONS - BASEMENT St a n l e y H o t e l C a r r i a g e H o u s e AO 05.04.2020 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS KB 1/4" = 1'-0" INTERIOR ELEVATION - LOBBY - EAST11/4" = 1'-0" INTERIOR ELEVATION - LOBBY - NORTH21/4" = 1'-0" INTERIOR ELEVATION - LOBBY - SOUTH4 1/4" = 1'-0" INTERIOR ELEVATION - LOBBY - WEST3 NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION. SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET. SHEET KEYNOTES 232 MECHANICAL DUCT RE; MECH 238 COVE LIGHTING BEYOND; RE: ELEC 239 RECLAIMED DIAGONAL BOARDS FROM DEMOLITION OF CARRIAGE HOUSE THIS WALL 1/4" = 1'-0" INTERIOR ELEVATION - THEATHER - EAST51/4" = 1'-0" INTERIOR ELEVATION - THEATHER - NORTH6 1/4" = 1'-0" INTERIOR ELEVATION - THEATHER - SOUTH71/4" = 1'-0" INTERIOR ELEVATION - THEATHER - WEST8 PTI-1 REVISION DATE ADDENDUM 1 2020.07.15 ASI 07 2021.03.17 AXON -BASEMENT BAR91/4" = 1'-0" INTERIOR ELEVATION- BAR - NORTH101/4" = 1'-0" INTERIOR ELEVATION - BAR - SOUTH11 ASI 07 1/4" = 1'-0" INTERIOR ELEVATION - B02A - NORTH12 DO O R P A N E L T Y P E S RE : S C H E D U L E RE: SCHED RE: SCHED RE : S C H E D U L E F FLUSH FG STILE AND RAIL GLAZED SAFETY GLAZING RE: SCHED RE : S C H E D U L E 43" MAXIMUM! 3' - 6" 6" N GLAZED (NOT USED) EXIT DEVICE 3' - 0" SAFETY GLAZING DOOR LEAF & FRAME ELEVATION TYPES FR A M E T Y P E S 1 2 RE: SCHEDULE 2" 2"RE: SCHED 2" RE: SCEDULE 2" 2"RE: SCHED 2" REMOVABLE MULLION FG4 GLAZED 3 RE: SCEDULE 2 3/4" 2 3/4"RE: SCHED 2 3/4" FG5 GLAZED 74 7/8" OVERALL FRAME WIDTH 116" OVERALL FRAME HEIGHT +/- 91 3/4" +/- 36" FG6 GLAZED 7/8" SDL 2 1/4" DOOR/FRAME THICKNESS FLAT PANEL: THICKNESS TO BE CONFIRMED 3" FRAME +/- 114 11/16" PANEL HEIGHT +/- 36 19/32" PANEL WIDTH 6"6" 6" 6" 4 1/2" SDL 36" CL OF PANIC HDW 75 5/8" OVERALL ROUGH OPENING WIDTH 116 1/2" OVERALL ROUGH OPENING HEIGHT 36" CL OF PANIC HDW 6" 6" EQ EQ 6" 4 1/2" SDL 7/8" SDL 2 1/4" DOOR/FRAME THICKNESS FLAT PANEL: THICKNESS TO BE CONFIRMED 3" FRAME DO O R P A N E L T Y P E S RE: SCHEDULE RE: SCHED G4 STILE AND RAIL GLAZED OBSCURE SAFETY GLAZING RE: SCHEDULE RE: SCHED F4 4 PANEL RECESSED PANEL SAFETY GLAZING THROUGHOUT SAFETY GLAZING THROUGHOUT WINDOW LEGEND WI N D O W / D O O R P A N E L T Y P E S W1 W2 FIXED 34 1/4" 82" OVERALL FRAME HEIGHT 76" OVERALL FRAME WIDTH BI-FOLD PARTITION RE: PLAN FOR DIRECTION FIXED W4 DOOR 103 DOOR 102 DOOR 104 W3 FIXED W4 FIXED W5 153 11/32" OVERALL FRAME WIDTH 116" OVERALL FRAME HEIGHT FIXED EQ EQ EQ 116W6 108" 94" BI-FOLD PARTITION RE: PLAN FOR DIRECTION 6" 6" 7/8" SDL 2 1/4" DOOR/FRAME THICKNESS FLAT PANEL: 1 1/4" THICKNESS 6" 1 3/16" EXPOSED FRAME 1 3/16" 1 5/16" EXPOSED FRAME 3" FRAME 6" 12' - 0" OVERALL FRAME WIDTH 116" OVERALL FRAME HEIGHT EQ EQ EQ EQ 1" SDL WITH 3/8" DEPTH (EACH SIDE) 2 3/4" DOOR/FRAME THICKNESS 3 7/8" 1 3/8" EXPOSED FRAME 1 3/8" 1 3/8" EXPOSED FRAME 2" SDL EQ 3" FRAME EQ DOOR 108 36"EQ EQ 38" EQ 4 1/2" SDL EQ 4 5/8" FRAME 116 1/2" OVERALL ROUGH OPENING HEIGHT 154 1/4" OVERALL ROUGH OPENING WIDTH 9' - 9" OVERALL ROUGH OPENING HEIGHT 12' - 3 1/2" OVERALL ROUGH OPENING WIDTH 7/8" GLAZING Cardinal LowE 272 with i89 SAFETY GLAZING THROUTHOUT INTERIOR GLAZING BEAD: BEVELED 7/8" GLAZING Cardinal LowE 272 with i89 SAFETY GLAZING THROUGHOUT INTERIOR GLAZING BEAD: BEVELED76 1/4" OVERALL ROUGH OPENING WIDTH 82" OVERALL ROUGH OPENING HEIGHT 151 5/8" OVERALL FRAME WIDTH 116" OVERALL FRAME HEIGHT EQ +/- 74 7/8"EQ 6" 6" 7/8" SDL 2 1/4" DOOR/FRAME THICKNESS FLAT PANEL: THICKNESS TO BE CONFIRMED 6" 1 3/16" EXPOSED FRAME 1 3/16" 1 5/16" EXPOSED FRAME 3" FRAME 6" 116 1/2" OVERALL ROUGH OPENING HEIGHT 152 3/8" OVERALL ROUGH OPENING WIDTH 7/8" GLAZING Cardinal LowE 272 with i89 SAFETY GLAZING THROUTHOUT INTERIOR GLAZING BEAD: BEVELED 3' - 2" EQ 4 1/2" SDL EQ 4 5/8" FRAME 151 1/4" OVERALL FRAME WIDTH 116" OVERALL FRAME HEIGHT EQ EQ EQ EQ 7/8" SDL 2 1/4" DOOR/FRAME THICKNESS FLAT PANEL: THICKNESS TO BE CONFIRMED 1 3/16" EXPOSED FRAME 1 3/16" 1 5/16" EXPOSED FRAME 38" EQ 4 1/2" SDL EQ 4 5/8" FRAME 116 1/2" OVERALL ROUGH OPENING HEIGHT 152" OVERALL ROUGH OPENING WIDTH 7/8" GLAZING Cardinal LowE 272 with i89 INTERIOR GLAZING BEAD: BEVELED 6" 6" 6" 3" FRAME 6" 4" MAPES PANEL BY GLAZER, NOT NANAWALL 38" SAFETY GLAZING REQUIRED 2 3/4" 3 1/2" Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 8 / 2 0 2 1 4 : 3 7 : 3 8 P M A-601 DOOR AND WINDOW SCHEDULE St a n l e y H o t e l C a r r i a g e H o u s e Author 05.04.2020 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS Checker DOOR AND FRAME SCHEDULE MARK PAIR DOOR FRAME HARDWARE NOTES SIZE MATL EL MATL EL SET NOWIDTH HEIGHT 01A 3' - 0" 7' - 6" WD F4 WD 1 05 01B 3' - 0" 7' - 6" WD G4 WD 1 08 02A PAIR 3'-0" 6' - 0" 7' - 6" WD F4 WD 2 09 TO BE INTEGRATED INTO BOOKSHELF LOBBY SIDE. F4 THEATER SIDE 02B 3' - 0" 7' - 6" HM F4 HM 1 02 02C 3' - 0" 7' - 6" WD F4 WD 1 04 02D 03A PAIR 3'-0" 6' - 0" 7' - 6" WD G4 WD 2 03 04A 3' - 0" 7' - 6" WD G4 WD 1 01 05A 3' - 0" 7' - 6" WD G4 WD 1 01 06A 3' - 0" 7' - 0" HM F HM 1 08 07A 3' - 0" 7' - 0" HM F HM 1 06 PANIC HARDWARE, 1HR RATED 07B 3' - 0" 7' - 0" HM F HM 1 07 EXTERIOR DOOR, 1HR RATED 08A 3' - 0" 7' - 0" HM F HM 1 05 100 PAIR 5' - 10" 9' - 6" AL/WD FG4 WD FG4 KOLBE-02 101 PAIR 5' - 10" 9' - 6" AL/WD FG4 WD FG4 KOLBE-02 102 2' - 10 1/2" 9' - 5" AL/WD FG5 WD W3 KOLBE-01 103 5' - 6" 9' - 5" AL/WD FG4 WD W4 KOLBE-02 104 2' - 10 1/2" 9' - 5" AL/WD FG5 WD W3 KOLBE-01 105 PAIR 5' - 10" 9' - 6" AL/WD FG4 WD FG4 KOLBE-02 106 3' - 6" 8' - 0" HM F HM 1 10 107 3' - 0" 7' - 0" WD F4 WD 1 04 109 3' - 2" 9' - 6" WD FG6 WD W6 INTERIOR NANAWALL 110 PAIR 5' - 10" 9' - 6" AL/WD FG4 WD FG4 KOLBE-02 GERNERAL NOTES: 1. ALL WINDOWS TO BE ALUMINUM CLAD WOOD WITH LOW E GLAZING 2. INTERIOR STAIN TO BE SELECTED BY T.I. ARCHITECT 3. ALL GLAZING WITHIN DOORS AND WINDOWS TO BE SAFETY GLAZING PER IBC 2406.4 AND 2406.3. ADD 1 ADD 1 ADD 2 ADD 2 ADD 4 ADD 4 REVISION DATE ADDENDUM 1 2020.07.15 ADDENDUM 2 2020.07.22 ADDENDUM 4 2021.02.16 ASI 07 2021.03.17 ASI 07 © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 1 / 2 0 2 1 5 : 5 8 : 1 5 P M M-002 MECHANICAL SCHEDULES St a n l e y H o t e l C a r r i a g e H o u s e KRD 2020.04.10 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS PBM BCER PROJECT 89319007 MAKE-UP AIR UNIT SCHEDULE PLAN CODE MFR. MODEL INSTALLED FAN DATA HEATER DATA COOLER DATA ELEC. DATA FILTER APPROX. OPPER. WEIGHT (LBS.) REMARKS MFR. MODEL CFM @ ALT. E.S.P. IN. W.C. @ S.L. H.P TYPE EAT (°F) LAT (°F) MBH INPUT @ S.L. MBH OUTPUT @ ALT. MIN. GAS PRESSURE (IN. W.C.) MAX. GAS PRESSURE (IN. W.C.) TURN DOWN FILL MEDIA EFF. (%) (8) MCA MOCP VOLT/PH. MAU-1 CAPTIVEAIRE A4-D.1000-920 10000 1.0 7.5 DIRECT -20 69.5 1055 725 7 14 10:1 CELDEK 80 25 30 460/3 MERV 8 2500 (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13) (7) PROVIDE SCCR RATING OF 5K. (6) PROVIDE STAINLESS STEEL HEAT EXCHANGER.(13) MOTOR HORSEPOWER ADJUSTMENTS TO INCLUDE REVISIONS NEEDED FOR UNIT DELTA P ADJUSTMENTS, COST OF INCREASE TO BE BORNE BY MANUFACTURER. (5) UNIT SHALL BE INTERLOCKED TO RUN ANYTIME KEF-1 OR KEF-2 RUNS. PROVIDE WALL THERMOSTAT FOR VENTILATION COOLING DURING SUMMERTIME OPERATION SET TO 70°F. (12) UNIT PRESSURE DROPS NEED TO BE ADJUSTED BY MANUFACTURER DURING SHOP DRAWING PHASE. (4) PROVIDE DISCHARGE AIR CONTROL TO MAINTAIN 70°F DISCHARGE AIR.(11) FILTER PRESSURE DROP FOR FAN SIZE "BASED ON MEDIUM DIRTY RANGE; NOT CLEAN". (3) PROVIDE UNIT WITH PACKAGED CONTROLS SYSTEM. INTERLOCK WITH GREASE HOOD CONTROL PANEL AND GREASE FAN. (10) PROVIDE UNIT WITH VAV PACKAGE AND MANUAL CONTROL OPTION. (2) PROVIDE AUTOMATIC FILL AND DRAIN KIT.(9) EVAPORATIVE MEDIA EFFICIENCY IS BASED ON 400 FPM. (1) PROVIDE ELECTRONIC GAS VALVE MODULATION.(8) PROVIDE AN AIR FLOW PROVING SWITCH WITH THE MAKE-UP AIR UNIT TO PREVENT ANY ONE OF THE GAS VALVES FROM OPENING PRIOR TO PROOF OF FLOW. MINI SPLIT AIR CONDITIONING UNIT SCHEDULE PLAN CODE MFR. MODEL INSTALLED SYSTEM LOCATION CFM FAN WATTS EAT LAT NOMINAL MBH AMB. TEMP. °F REFRIGERANT SEER ELEC. DATA FILTER WEIGHT REMARKS MFR. MODEL °F DB °F WB °F DB °F WB TYPE CHARGE (LBS.) MCA MOCP VOLT/PH. TYPE % EFF. AC-1 DAIKIN FTXS30LVJU CU-1 ELEC ROOM 700 64 78 58 45 54 30 - R-410A 10 19.3 19.5 20 - TA MERV 8 50 CU-1 DAIKIN RKS20LVJU AC-1 ROOF 2630 200 - - - - 30 115 / -40 R-410A 10 19.3 - - 208/1 - - 200 (3) PROVIDE UNIT WITH ENERGY COMPLIANCE TO ADOPTED ASHRAE 90.1 REQUIREMENTS. (2) PROVIDE WITH UNIT MOUNTED DISCONNECT.(5) PROVIDE WITH FIELD FABRICATED ROOF CURB. (1) PROVIDE LOW AMBIENT CONTROL FOR OPERATION DOWN TO -20°F DB.(4) PROVIDE CONDENSATE DRAIN WITH CONDENSATE PUMP. FAN SCHEDULE PLAN CODE MFR. MODEL INSTALLED SYSTEM FAN TYPE CFM @ ALT. S.P. IN. W.C. @ S.L. WHEEL TYPE / DIAMETER FAN RPM (APPROX.) DRIVE TYPE H.P. DAMPER MOUNTING TYPE ELEC. VOLT/PH. APPROX. WEIGHT (LBS.) REMARKS MFR. MODEL TYPE SIZE EF-1 GREENHECK G-143-A RESTROOM CENTR. 1935 1.2 BI / 14.6 1725 DIRECT 1 GRAVITY ROOF 460/3 100 (1)(4)(7)(8) EF-2 US DRAFT CO CBx607 DOAS FLUE CENTR. 365 0.08 - 1950 DIRECT 1/2 - INLINE 120/1 40 (6)(7)(8)(9) KEF-1 GREENHECK GB-300 GREASE HOOD CENTR. 10000 1.2 BI / 30.5 785 BELT 3 - ROOF 460/3 250 (2)(3)(4)(7)(8) KEF-2 GREENHECK GB-161HP DISHWASH CENTR. 1400 1.2 BI / 16.6 1520 BELT 3/4 GRAVITY ROOF 460/3 120 (1)(2)(7)(8) (9) PROVIDE EXHAUST FAN RATED FOR USE WITH FLUE GAS. 316L SS. PROVIDE CONTROLS. (8) MOTOR HORSEPOWER ADJUSTMENTS TO INCLUDE REVISIONS NEEDED FOR UNIT DELTA P ADJUSTMENTS, COST OF INCREASE TO BE BORNE BY MANUFACTURER. (7) UNIT PRESSURE DROPS NEED TO BE ADJUSTED BY MANUFACTURER DURING SHOP DRAWING PHASE. (6) PROVIDE WITH CONSTANT PRESSURE CONTROLLER. (5) PROVIDE INLET SCREEN. (4) PROVIDE UNIT MOUNTED SPEED CONTROL SWITCH. (3) PROVIDE WITH VFD. (2) PROVIDE BELT AND MOTOR GUARD. (1) PROVIDE WITH INLET GUARD. AIR HANDLING UNIT SCHEDULE (GAS FIRED) PLAN CODE MFR. MODEL INSTALLED LOCATION AREA SERVED SUPPLY FAN DATA HEATING DATA APPROX. UNIT DIMENSIONS ELEC. DATA OPER. WEIGHT (LBS.) REMARKS MFR. MODEL CFM @ ALT. MIN O.A. E.S.P. IN. W.C. @ S.L. RPM (APPROX.) BHP HP EAT (°F) LAT (°F) TYPE INPUT @ S.L. MBH OUTPUT @ ALT. MBH MIN GAS PRESSURE (IN. W.C.) MAX GAS PRESSURE (IN. W.C.) TURN DOWN LENGTH (IN.) WIDTH (IN.) HEIGHT (IN.) MCA MOCP VOLT/PH. DOAS-1 CAPTIVEAIRE A2-IBT-400-200 -200 MECH ROOM FCUs 3500 3500 0.7 1715 2.4 3 -20 70.7 INDIRECT 444.6 257 7 14 12:1 133 50 40 25 30 460/3 1500 (1)(2)(3)(4)(5)(6)(7) (5) MOTOR HORSEPOWER ADJUSTMENTS TO INCLUDE REVISIONS NEEDED FOR UNIT DELTA P ADJUSTMENTS, COST OF INCREASE TO BE BORNE BY MANUFACTURER. (4) UNIT PRESSURE DROPS NEED TO BE ADJUSTED BY MANUFACTURER DURING SHOP DRAWING PHASE. (3) FILTER PRESSURE DROP FOR FAN SIZE "BASED ON MEDIUM DIRTY RANGE; NOT CLEAN" (2) FILTER AIR PRESSURE DROP IS INLUDED WITH THE AIR HANDLING UNIT, THE IN THE EXTERNAL PRESSURE DROP.(7) PROVIDE UNIT WITH TERMINAL STRIP FOR CONTROLS. (1) CONTRACTOR / SUPPLIER SHALL VERIFY THE INTERNAL UNIT PRESSURE DROPS AND ADJUST THE BHP/MOTOR H.P. REQUIREMENTS.(6) UNIT SCCR RATING OF 5K. UNIT HEATER SCHEDULE (ELECTRIC) PLAN CODE MFR. MODEL INSTALLED DISCHARGE KW FLA CFM @ ALT. EAT (°F) LAT (°F) THROW (FT.) RPM H.P. ELEC. VOLT/PH. REMARKS MFR. MODEL UH-1 QMARK IUH-1048 HORIZONTAL 10 12.8 500 45 121.7 20 1550 1/10 480/3 (1)(2)(3) (3) LIGHT COMMERCIAL HORIZONTAL MOUNT UNIT HEATER WITH INTEGRAL MOUNTING BRACKET. SUSPEND FROM CEILING, WITH BOTTOM OF UNIT 8'-0" A.F.F. (2) PROVIDE INTEGRAL POWER DISCONNECT. (1) PROVIDE UNIT MOUNTED THERMOSTAT WITH SPEED CONTROL SWITCH. 6. DAIKIN BRANCH SELECTOR UNITS, BS4Q54VJ, BSQ60TVJ. 5. DAIKIN VRF TOUCHSCREEN CONTROL PANEL. INTERLOCK VRF FAN COIL UNITS, CONDENSING UNITS, AND DOAS TOGETHER. 4. TEKMAR 090 SNOWMELT SNOW/ICE SENSOR. 3. TEKMAR 665 SNOWMELT CONTROL PANEL. 2. DRAFT CO, V200-V FLUE FAN CONTROL PANEL. 1. CAPTIVEAIRE GREASE HOODS TO BE INSTALLED IN SEPARATE SUBMITTAL AND IS NOT PART OF THIS PACKAGE. GREASE HOOD ASSUMPTIONS FOR SIZING MAU FOLLOWS: 10,000 CFM OF TOTAL EXHAUST. #1: 12'-6" LENGTH. #2: 16' LENGTH. PROVIDE WITH PACKAGED CONTROLS AND DEMAND CONTROL VENTILATION TO MODULATE GREASE FAN. CONTROL PANEL TO INTERLOCK GREASE HOOD, GREASE FAN, AND MAU TOGETHER. MISC. EQUPIMENT ADD 1 07 ASI REVISION DATE ADDENDUM 1 2020.07.15 ASI 07 2021.03.17 03/17/21 MAU-1 DOAS-1 T 4 3 2 1 AC DE MEN'S RESTROOM B04 WOMEN'S RESTROOM B05 LOUNGE B02 MECH ROOM B06 TI STORAGE B08 OAL-1 110x48 3500 B-1 GF CP-1 ET-1 ER-1 8x6 100 ER-1 12x12 400 TYP.2 16x12 26x12 12Ø 12Ø 12 x 1 2 50 x 2 4 36 x 1 0 OAL-3 110x126 27000 EXHAUST INTAKE FCU-1 38 x 1 4 FCU-2 38 x 1 4 FCU-3 38 x 1 4 20 x 1 6 38x1650x24AC-1 CU-2 CU-3 CU-1 CP-2 6Ø 6Ø 1 M-401 2 M-401 EXHAUST 8Ø 28x24 M2 M1 3 M-401 M3 M4 INTAKE M5 M6M7 12Ø 12Ø 4Ø4Ø M8 M8 M9M9M9 4 M-401 B UH-1 RG-2 RG-1 RG-2 M28 M29 M29 M30 M31 M31 M31SD-1 135 8Ø TYP.6 24x1012x10 12x10 24x10 SD-1 135 8Ø TYP.6 24x12 24x12 8Ø 6Ø 32 x 1 2 12x12 12Ø SG-1 14x8 54512 Ø SG-1 8x4 50 TG-1 20x12 SG-1 10x10 115 8Ø RG-3 10x10 12 Ø 16x16 M32 OAL-2 110x34 10000 M33M33 M38 SG-1 6x6 50 18x12 B.O.H. B02A BAR B03 LOBBY B01 BOH HALL B01B LS-1 96", 2 SLOTS(S) 220 M45 8Ø 5 M-401 ER-1 6x6 70 6Ø ADD 1 TG-1 10x6 TYP.2 07 ASI 32x10 UP M49 07 ASI 07 © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 1 / 2 0 2 1 5 : 5 8 : 1 6 P M M-200 BASEMENT MECHANICAL PLAN St a n l e y H o t e l C a r r i a g e H o u s e KRD 2020.04.10 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS PBM BCER PROJECT 89319007 2. CLOSELY COORDINATE ALL DUCTWORK ELEVATIONS WITH ALL OTHER DISCIPLINES. 1. ALL EXPOSED INTERIOR DUCTWORK SHALL BE PRIMED FOR PAINTING. COORDINATE WITH ARCHITECT FOR PAINT COLOR. GENERAL NOTES N 0 4'4' 2' 1/4" = 1'-0" 1 BASEMENT MECHANICAL PLAN WORK NOTES M8 PROVIDE SHEETMETAL DIVIDER IN AREA WELL TO SEPARATE EXHAUST FROM INTAKE AIR. REFER TO SECTION VIEWS. M9 DUCT CONDENSING UNIT EXHAUST TO EXTERIOR LOUVER. REFER TO SECTION VIEWS. M28 BALANCE TO 965 CFM. M29 BALANCE TO 535 CFM. M30 BALANCE TO 535 CFM. M31 PROVIDE ACCESS PANEL UNDER FAN COIL UNIT. M32 ROUTE DUCT UP AND DOWN TO PROVIDE HIGH/LOW COMBUSTION AIR FOR DOAS-1. TERMINATE HIGH DUCT 12" FROM CEILING AND LOW DUCT 12" FROM FLOOR. M33 PROVIDE 24X24 TRANSFER GRILLE IN DOOR. COORDINATE WITH ARCHITECT. M38 PROVIDE FAN COIL UNIT AND CONDENSING UNIT, VRF SYSTEM, CONTROL PANEL LOCATED ON WALL. M45 PROVIDE 8' LINEAR SLOT GRILLE. THIS SHALL BE USED FOR SUPPLY AND RETURN AIR TO SPACE. PROVIDE WITH 4' PLENUM BOX FOR SUPPLY CONNECTION. REMAINING 4' SHALL BE RETURN PATH TO CEILING PLENUM. M49 PROVIDE TRANSFER GRILLES LOCATED BETWEEN THE TOP OF THE DOOR AND BOTTOM OF THE CEILING. WORK NOTES M1 COMBINE BOTH FURNACE FLUE DUCTS FROM DOAS INTO A COMMON FLUE. INSTALL FITTINGS PER MANUFACTURER REQUIREMENTS. M2 PROVIDE FLUE FAN, EF-2, VENT CONTROL SYSTEM PANEL LOCATED ON WALL. INSTALL PER MANUFACTURER REQUIREMENTS. DRAFT CO, V200-V. M3 MAU LOCATED ON MECH ROOM FLOOR WITH HOUSEKEEPING PAD. DOAS SUSPENDED ABOVE MAU. M4 PROVIDE PERMINATE SUPPORT STAND FOR SEVICING DOAS. FLOOR OF SUPPORT STAND SHALL BE LEVEL WITH BOTTOM OF DOAS. ENSURE CLEARANCES FOR MAU BELOW ARE MAINTAINED. M5 PROVIDE HOUSEKEEPING PAD FOR GLYCOL FEEDER. M6 ROUTE FLUE AND COMBUSTION AIR DUCT DOWN TO WATER HEATER. REFER TO PLUMBING. COORDINATE EXACT FLUE EQUIVALENT LENGTH WITH FLUE SIZE PER MANUFACTUER REQUIREMENTS. M7 ROUTE FLUE AND COMBUSTION AIR DUCT DOWN TO BOILER. COORDINATE EXACT FLUE EQUIVALENT LENGTH WITH FLUE SIZE PER MANUFACTUER REQUIREMENTS. ADD 1 REVISION DATE ADDENDUM 1 2020.07.15 ASI 07 2021.03.17 03/17/21 © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 4 : 5 9 P M E-002 ELECTRICAL SCHEDULES St a n l e y H o t e l C a r r i a g e H o u s e DAP 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS DKH BCER PROJECT 89319007 LUMINAIRE SCHEDULE KEY SOURCE POWER DESCRIPTION FINISH MOUNTING MANUFACTURER CATALOG # NOTES TYPE CRI CCT DELIVERED LUMENS VOLT VA DIMMING TYPE DEPTH MOUNT HEIGHT A4 LED 80 3500 4800 277 V 55 0-10V 4' LENSED LED STRIP STANDARD SURFACE OR CHAIN 3.06" COLUMBIA MPS4-35ML-CPW-EU B3L LED 80 3500 1268 277 V 14 0-10V 3' LONG 4" PEREMITER SLOT WITH TELESCOPING LIT END ON LEFT HAND SIDE WHITE RECESSED 5-1/8" FINELITE HP-WS-4W-2D-3'-S-835-277V -SC-WB-SW-TXL-L-SF B3R LED 80 3500 1268 277 V 14 0-10V 3' LONG 4" PEREMITER SLOT WITH TELESCOPING LIT END ON RIGHT HAND SIDE WHITE RECESSED 5-1/8" FINELITE HP-WS-4W-2D-3'-S-835-277V -SC-WB-SW-TXL-R-SF B8 LED 80 3500 2536 277 V 32 0-10V 8' LONG 4" PEREMITER SLOT WHITE RECESSED 5-1/8" FINELITE HP-WS-4W-2D-8'-S-835-277V -SC-WB-SW-xxx-SF C4 LED 80+ 3500 2500 277 V 28 0-10V 4" SQUARE LED DOWNLIGHT STANDARD RECESSED 6.02" PRESCOLITE LTR - 4SQD - H - ML25L - DM1 - LTR-4SQD-T - ML35K8WDS - XXX (1) CD LED 2700 120 V 360 NONE 6-LAMP CEILING FIXTURE BLACK SURFACE 7.5" CDS DUKE-B-USV (2) CDM LED 2700 120 V 240 NONE 4-LAMP DECORATIVE CEILNG FIXTURE BLACK SURFACE 7.5" CDS DUKE MINI-B-USV (2) D4 LED 80+ 3500 2000 277 V 23 0-10V 4" SQUARE LED DOWNLIGHT STANDARD RECESSED 6.02" PRESCOLITE LTR - 4SQD - H - ML20L - DM1 - LTR-4SQD-T - ML35K8WDS - BT - B24 E24 LED 80 3500 4103 277 V 32 0-10V 2'X4' LED EDGE LIT FLAT PANEL WHITE BAKED ENAMEL RECESSED 1.68" COLUMBIA CFP24-4135-HE F1 LED 3000 1887 277 V 22 0-10V 14" METAL DOME PENDANT WITH WIRE GUARD AND CORD DROP MOUNTING. ** PENDANT +9'-0" ABOVE STAIRS TMS CAL-I-14-19WLED-CRD-30K- 277-**-DIML-W14 F2 LED 3000 1887 277 V 22 0-10V 14" METAL DOME PENDANT WITH WIRE GUARD AND CORD DROP MOUNTING. ** PENDANT +9'-0" ABOVE STAIRS TMS CAL-I-14-19WLED-CRD-30K- 277-**-DIML-W14 F3 LED 3000 1887 277 V 22 0-10V 14" METAL DOME PENDANT WITH WIRE GUARD AND CORD DROP MOUNTING. ** PENDANT +9'-0" ABOVE STAIRS TMS CAL-I-14-19WLED-CRD-30K- 277-**-DIML-W14 TS LED 2700 120 V 40 ANTIQUE TIN PANEL WITH CUSTOM SOCKET AND BOX WITH 6' WIRE WHIP CLEAR RECESSED 4" LUMOS #TS22 (4) W2 LED 80 3500 2300 277 V 18 0-10V MULTI-PURPOSE LINEAR, STANDARD, WALL, 2'Lx3.1"Wx3.1"H, ABOVE MIRROR WALL COLUMBIA MPS-2-35MW-CW-EDU WJ LED 2700 120 V 60 NONE DECORATIVE WALL SCONCE STANDARD WALL 6" ** CDS JANELLE-B-USV (2) (3) X1 LED N/A N/A N/A 277 V 4 NONE SINGLE FACE LED EXIT SIGN WHITE UNIVERSAL --- DUAL-LITE SESGWE X2 LED N/A N/A N/A 277 V 4 NONE DOUBLE FACE LED EXIT SIGN WHITE UNIVERSAL --- DUAL-LITE SEDGWE AA LED 70 3000K 1830 277 V 25 0-10V DECORATIVE LED BOLLARD WITH TYPE III DISTRIBUTION ARCTIC WHITE GROUND MOUNTED ARCHITECTURAL AREA LIGHTING PROB-Y3-2030-WH-DSC-RD C3W LED 80+ 3000 1500 277 V 19 0-10V 3" SQUARE LED DOWNLIGHT WITH WALL WASH REFLECTOR AIMED AWAY FROM BUILDING STANDARD RECESSED 6.02" PRESCOLITE LTR-3SQD-RH-SL15L-DM1-L TR-3SQW-T-SL30K8LWW-SS (1) DD LED 277 V 0 0-10V EXTERIOR STEPLIGHT RECTANGLE WHITE 3-1/16" +3'-0" BRUCK 138022-WH-3-HC (5) EE LED 70 3000 1830 277 V 100 0-10V DECORATIVE WALL SCONCE WITH TYPE III DISTRIBUTION ARCTIC WHITE WALL ** ARCHITECTURAL AREA LIGHTING PROS-Y3-2030-WH-WMA59U (5) PROVIDE HANGER BAR SET AS REQUIRED. PART #76064. (4) PROVIDE 40W MAX LABEL. (3) ARCHITECT/OWNER TO SELECT STANDARD FINISH. (2) PROVIDE 60W MAX LABEL. (1) COORDINATE WITH CEILING TYPE AND PROVIDE REQUIRED MOUNTING HARDWARE. LUMINAIRE SCHEDULE PROJECT SPECIFIC NOTES C. SUBMITTALS FOR ALL LUMINAIRES MUST INCLUDE PROJECT SPECIFIC SHOP DRAWINGS INDICATING ALL PARTS AND ACCESSORIES REQUIRED FOR A COMPLETE AND OPERATIONAL ASSEMBLY. B. VERIFY EXACT LENGTHS OF LUMINAIRE COMPONENTS WITH ARCHITECTURAL RCP AND ARCHITECTURAL ELEVATIONS PRIOR TO STARTING WORK. A. COORDINATE AND VERIFY ALL LUMINAIRE REQUIREMENTS WITH ARCHITECT PRIOR TO SUBMITTALS INCLUDING, BUT NOT LIMITED TO, MOUNTING METHOD, MOUNTING HEIGHT(S), AND FINISHES AND/OR COLORS. LUMINAIRE SCHEDULE GENERAL NOTES MECHANICAL EQUIPMENT SCHEDULE TAG DESCRIPTION VOLTAGE PHASE HP MCA KW KVA DISC. SIZE PANEL CIRCUIT CB SIZE FEEDER SIZE REMARKS AC-1 SPLIT SYSTEM INDOOR UNIT 208 V 1 19.5 4.1 30/2 LBA 27,29 20 (2#12 & 1#12G)3/4"C ACU-1 SPLIT SYSTEM CONDENSING UNIT 208 V 1 0.0 LBA 27,29 20 (2#12 & 1#12G)3/4"C WIRE THRU AC-1 B-1 CONDENSING HOT WATER BOILER 120 V 1 0.2 STO LBA 16 20 (2#12 & 1#12G)3/4"C BS-1A BRANCH SELECTOR BOX - CU-1 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-1B BRANCH SELECTOR BOX - CU-1 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-1C BRANCH SELECTOR BOX - CU-1 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-2A BRANCH SELECTOR BOX - CU-2 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-2B BRANCH SELECTOR BOX - CU-2 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-2C BRANCH SELECTOR BOX - CU-2 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-3A BRANCH SELECTOR BOX - CU-3 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-3B BRANCH SELECTOR BOX - CU-3 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C BS-3C BRANCH SELECTOR BOX - CU-3 208 V 1 0.1 STO LBA 33,35 15 (2#12 & 1#12G)3/4"C CP-1 CIRCULATION PUMP 120 V 1 1/10 0.2 STO LBA 18 20 (2#12 & 1#12G)3/4"C CP-2 CIRCULATION PUMP 120 V 1 1/10 0.2 STO LBA 14 20 (2#12 & 1#12G)3/4"C CU-1 CONDENSING UNIT 480 V 3 39.8 33.1 60/3 HMA 14,16,18 45 (3#8 & 1#10G)3/4"C CU-2 CONDENSING UNIT 480 V 3 43.3 36.0 60/3 HMA 19,21,23 50 (3#6 & 1#10G)3/4"C CU-3 CONDENSING UNIT 480 V 3 43.3 36.0 60/3 HMA 20,22,24 50 (3#6 & 1#10G)3/4"C DCP-1 DOMESTIC CIRCULATION PUMP 120 V 1 0.2 STO LBA 28 20 (2#12 & 1#12G)3/4"C DOAS-1 AIR HANDLING UNIT 480 V 3 3 4.0 30/3 HMA 1,3,5 15 (3#12 & 1#12G)3/4"C DWH-1 DOMESTIC WATER HEATER 120 V 1 0.2 STO LBA 30 20 (2#12 & 1#12G)3/4"C EF-1 EXHAUST FAN 120 V 1 3/4 1.6 30/1 LBA 41 20 (2#12 & 1#12G)3/4"C EF-2 EXHAUST FAN 120 V 1 1/2 0.5 30/1 L1A 13 20 (2#12 & 1#12G)3/4"C ESP-1 ELEVATOR SUMP PUMP 480 V 3 1 1.8 30/3 HMA 31,33,35 20 (3#12 & 1#12G)3/4"C FCU-1 FAN COIL UNIT 208 V 1 1.8 0.4 30/2 LBA 7,9 15 (2#12 & 1#12G)3/4"C FCU-2 FAN COIL UNIT 208 V 1 1.8 0.4 30/2 LBA 11,13 15 (2#12 & 1#12G)3/4"C FCU-3 FAN COIL UNIT 208 V 1 1.8 0.4 30/2 LBA 15,17 15 (2#12 & 1#12G)3/4"C FCU-4 FAN COIL UNIT 208 V 1 2.8 0.6 30/2 L1A 1,3 15 (2#12 & 1#12G)3/4"C FCU-5 FAN COIL UNIT 208 V 1 2.8 0.6 30/2 L1A 2,4 15 (2#12 & 1#12G)3/4"C FCU-6 FAN COIL UNIT 208 V 1 2.8 0.6 30/2 L1A 5,7 15 (2#12 & 1#12G)3/4"C FCU-7 FAN COIL UNIT 208 V 1 2.8 0.6 30/2 L1A 6,8 15 (2#12 & 1#12G)3/4"C FCU-8 FAN COIL UNIT 208 V 1 2.8 0.6 30/2 L1A 9,11 15 (2#12 & 1#12G)3/4"C FCU-9 FAN COIL UNIT 208 V 1 2.8 0.6 30/2 L1A 10,12 15 (2#12 & 1#12G)3/4"C IBT-1 INDIRECT BENT TUBE HEATER 120 V 1 1.2 STO LBA 37 15 (2#12 & 1#12G)3/4"C KEF-1 KITCHEN EXHAUST FAN 480 V 3 5 6.3 30/3 HMA 7,9,11 20 (3#12 & 1#12G)3/4"C KEF-2 KITCHEN EXHAUST FAN 480 V 3 3/4 1.3 30/3 HMA 8,10,12 15 (3#12 & 1#12G)3/4"C MAU-1 MAKE-UP AIR UNIT 480 V 3 7.5 9.1 30/3 HMA 2,4,6 30 (3#10 & 1#10G)3/4"C SP-1 SUMP PUMP 480 V 3 1 0.5 30/3 HMA 26,28,30 20 (3#12 & 1#12G)3/4"C UH-1 UNIT HEATER 480 V 3 10 10.0 30/3 HMA 25,27,29 20 (3#12 & 1#12G)3/4"C 1 1 1 1 1 1 1 1 7 ASI 07 REVISION DATE ADDENDUM 1 07/14/2020 ASI 07 03/17/2021 03/17/21 OS OS OS OS OS OS OS OS OS OS J J J J J J J J J J J J J J J J J J 4 3 2 1 AC DE A4 A4 A4A4 A4 A4A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 A4 B A4D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 D4 C4 B8 B8 B3L B3R B3R B3L X1 X1 X1 HBA-1 HBA INV L1 C4 INV-1 C1 C1 C1 MEN'S RESTROOM B04 WOMEN'S RESTROOM B05 MECH ROOM B06 TI STORAGE B08 LOUNGE B02 ELECTRICAL B07 B.O.H. B02A BAR B03 JANITOR B01A PLATFORM B02B MECH CONDENSER ROOM B07A ELEVATOR B10 BOH HALL B01B C2 L2 L2 L2 WJWJ WJ WJ WJ WJ CDM CDM CD CD L3 L3 L3 L3 WJWJ WJWJ WJWJ WJWJ C4 C4 TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS TS LBA LBA-21 LBA-23 L4 L4 INV-3 INV-4 LBA-25 INV-5 A4 A4 C4 C5 C5 C6 INV-6 C1 L6 C7 C8 TS 1 1 W2 C4 C4 © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 5 : 0 0 P M E-200 BASEMENT LIGHTING PLAN St a n l e y H o t e l C a r r i a g e H o u s e DAP 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS DKH BCER PROJECT 89319007 WORK NOTES C8 LIGHTING IN THIS ROOM SHALL BE CONTROLLED VIA LINE VOLTAGE WALL SWITH WITH INTEGRAL OCCUPANCY SENSOR AND 0-10V DIMMING. SENSOR SHALL BE SET TO 15 MINUTE TIME DELAY. L1 PROVIDE 3.7 KVA EMERGENCY LIGHTING INVERTER FOUR 277V-1PH OUTPUT BREAKERS, TWO 120V-1PH OUTPUT BREAKERS AND FACTORY STARTUP SERVICE. BASIS OF DESIGN IS DUAL-LITE D277-55S120/277-AC2006 (4X 277, 2X120)-SBC-CL60-FSL. L2 PROVIDE CONTECH TAPE LIGHT IN CHANNEL CREATED AT TOP OF DECORATIVE WALL TREATMENT. PROVIDE CONTECT TLT24V1RGBW, WITH REEL LENGTH AS REQUIRED. PROVIDE WITH POWER SUPPLIES, REPEATERS, CONNECTORS, ACCESSORIES, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. PROVIDE WITH ALUMINUM MOUNTING CHANNEL (TLACS6), QUANTITY AS REQUIRED. PROVIDE WITH FROSTED LENS (TLALF6), QUANTITY AS REQUIRED. PROVIDE WITH RGBW CONTROLLER (TLPRGBWRF). ALL TAPE LIGHT SHALL BE CONTROLLED FROM ONE REMOTE. DESIGN ASSUMES APPROXIMATELY 110' OF TAPE LIGHT FOR THE ENTIRE ROOM. COORDINATE EXACT MOUNTING WITH ARCHITECT. COORDINATE CONTROL INTENTION WITH OWNER. L3 LIGHT COVE TO BE CONTINUOUS. PROVIDE ALL NECESSARY ACCESSORIES FOR A COMPLETE INSTALLATION. L4 ALL LIGHTS IN THIS OUTLINE NOT CONNECTED TO THE INVERTER SHALL BE ON THE SAME CIRCUIT. L6 LIGHTING CONTROL PANEL. WORK NOTES C1 LIGHTING IN THIS ROOM SHALL BE CONTROLLED VIA LINE VOLTAGE WALL SWITCHES. PROVIDE A SEPARATE SWITCH FOR NORMAL POW ER LIGHTING, AND INVERTER POWER LIGHTING. NO AUTOMATIC CONTROLS ARE BEING PROVIDED FOR OCCUPANT SAFETY. C2 LIGHTING IN THIS ROOM SHALL BE CONTROLLED VIA LINE VOLTAGE WALL SWITCHES AND OCCUPANCY SENSORS. PROVIDE A SEPARATE SWITCH FOR NORMAL POWER LIGHTING, AND INVERTER POWER LIGHTING. OCCUPANCY SENSORS SHALL BE SET TO AUTO ON/AUTO OFF MODE FOR OCCUPANT SAFETY. EM LIGHTING SHALL NOT BE CONTROLLED BY OCCUPANCY SENSORS. C5 LIGHTING IN THIS ROOM SHALL BE CONTROLLED VIA CEILING MOUNTED OCCUPANCY SENSORS, AND A LINE VOLTAGE WALL SWITCH. EM LIGHTING SHALL BE UNSWITCHED. OCCUPANCY SENSORS SHALL BE SET TO AUTO ON/AUTO OFF WITH A 15 MINUTE TIME DELAY. C6 LIGHTING IN THIS ROOM SHALL BE CONTROLLED VIA CEILING OCCUPANCY SWITCH AND LOW VOLTAGE WALL SWITCH. WALL SWITCH SHALL PROVIDE ON/OFF AND 0-10V DIMMING CONTROL. OCCUPANCY SENSOR SHALL BE SET TO MANUAL ON/AUTO OFF MODE WITH A 30 MINUTE TIME DELAY. C7 LIGHTING IN THIS ROOM SHALL BE CONTROLLED VIA LOW VOLTAGE WALL SWITCHES. EACH WALL SWITCH SHALL PROVIDE 0-10V DIMMING AND ON/OFF CONTROL OF DOWNLIGHTS. ROOM CONTROLLER SHALL BE CONNECTED TO TIME CLOCK, AND PROGRAMMED FOR AUTO OFF OPERATION BASED UPON OWNER'S SCHEDULED HOURS. LIGHTS SHALL AUTOMATICALLY TURN OFF 1 HOUR AFTER NORMAL HOURS. TAPE LIGHT SHALL BE CONTROLLED SEPARATELY VIA REMOTE SWITCH LOCATED IN B.O.H. ROOM. COORDINATE WITH OWNER FOR CONTROLS IN THIS SPACE PRIOR TO ORDERING AND INSTALLATION. N 0 4'4' 2' 1/4" = 1'-0" 1 BASEMENT LIGHTING PLAN 7 ASI 07 REVISION DATE ADDENDUM 1 07/14/2020 ASI 07 03/17/2021 03/17/21 VFD M VFD M M TOM TOM TOM J J M M M VFD M VFD M VFD M M TOM TOM M J M TOM TOM TOM TOM TOM TOM TOM TOM TOM TOM J J 4 3 2 1 AC DE MDP XLDP XLBA HBALBAHMA LDP LBT E6 LBA-1 MECH ROOM B06 BAR B03 B.O.H. B02A MEN'S RESTROOM B04 WOMEN'S RESTROOM B05 LOUNGE B02 LOBBY B01 TI STORAGE B08 ELECTRICAL B07 LBT-1 LBT-3 LBA-3 LBA-5 JANITOR B01A LBA-8 LBA-6 LBA-10 ac ac E13 DOAS-1 MAU-1 AC-1 B-1 CP-1 CP-2 +36" FCU-2FCU-2 FCU-1 FCU-3 CU-1 CU-2 CU-3 B LBA-12 LBA-20 LBA-22 LBA-24 INV E16 UH-1 E18 DWH-1 DCP-1 SP-1 ESP-1 LBA-26 MECH CONDENSER ROOM B07A 1 E21 BS-1A BS-1B BS-1C BS-2A BS-2B BS-2C BS-3A BS-3B BS-3C 1 IBT-1 E22 LBA-39 1 ac LBA-2 UC FRIG DW LBA-38 LBA-40 LBA-42 ac POS 7 ASI 07 E25 © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 5 : 0 0 P M E-300 BASEMENT POWER PLAN St a n l e y H o t e l C a r r i a g e H o u s e DAP 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS DKH BCER PROJECT 89319007 N 0 4'4' 2' 1/4" = 1'-0" 1 BASEMENT POWER PLAN WORK NOTES E6 PROVIDE G.E. FUSIBLE SHUNT TRIP ELEVATOR SWITCH, PART #ES1T48R2GC OR APPROVED EQUAL. PROVIDE ALL REQUIRED CONNECTIONS TO FIRE ALARM. COORDINATE RELAY VOLTAGE WITH FIRE ALARM CONTRACTOR PRIOR TO ORDERING. PROVIDE WITH J-CLASS FUSES, REFER TO ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION. E13 PANEL TO BE PROVIDED FOR THEATER COMPANY USE. EXACT LOCATION TO BE COORDINATED WITH OWNER PRIOR TO INSTALLATION. E16 PROVIDE PLYWOOD BACKING FOR OWNER'S TELECOM EQUIPMENT. COORDINATE EXACT SIZE AND LOCATION WITH OWNER'S TELECOM CONTRACTOR. E18 FOR GLYCOL FEEDER. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. E21 PROVIDE DOOR WITH PANIC HARDWARE. E22 POWER FOR CONTROL PANEL HEATER ENCLOSURE. FIELD VERIFY AND COORDINATE ALL REQUIREMENTS WITH EQUIPMENT PROVIDED PRIOR TO ROUGH IN. E25 BLANK GFCI OUTLET DEVICE FOR PROTECTION OF ADJACENT DEDICATED DISHWASHER AND REFRIGERATOR RECEPTACLES. COORDINATE ACCESSIBLE LOCATION OF SUCH DEVICE WITH ARCHITECT AND OWNER. 1 REVISION DATE ADDENDUM 1 07/14/2020 ASI 07 03/17/2021 7 ASI 07 03/17/21 © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 5 : 0 0 P M E-502 PANEL SCHEDULES St a n l e y H o t e l C a r r i a g e H o u s e DAP 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS DKH BCER PROJECT 89319007 [1] LOAD SHOWN IS CONNECTED LOAD. PANEL CAPACITY:225 A Appliance - Commercial 1700 VA 100.00% 1700 VA SPARE CAPACITY:188 A Lighting 8947 VA 125.00% 11184 VA DEMAND CURRENT:37 A Equipment 1050 VA 100.00% 1050 VA Receptacle 5520 VA 100.00% 5520 VA DEMAND LOAD:30356 VA Motor 9877 VA 110.38% 10902 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS TOTAL CONNECTED LOAD:10622 VA 8885 VA 7587 VA 41 SPARE 1 20 0 7587 -- -- -- 42 39 SPARE 1 20 0 8240 -- -- -- 40 37 SPARE 1 20 0 5080 70 3 XLBA 38 35 SPARE 1 20 0 0 20 1 SPARE 36 33 SPARE 1 20 0 0 20 1 SPARE 34 31 SPARE 1 20 0 0 20 1 SPARE 32 29 SPACE -- --0 0 -- -- SPACE 30 27 SPACE -- -- 0 0 -- -- SPACE 28 25 SPACE -- -- 0 0 -- -- SPACE 26 23 SPACE -- --0 0 -- -- SPACE 24 21 SPACE -- -- 0 0 -- -- SPACE 22 19 SPACE -- -- 0 0 -- -- SPACE 20 17 SPACE -- --0 0 -- -- SPACE 18 15 SPACE -- -- 0 0 -- -- SPACE 16 13 SPACE -- -- 0 0 -- -- SPACE 14 11 SPACE -- --0 0 -- -- SPACE 12 9 SPACE -- -- 0 0 -- -- SPACE 10 7 SPACE -- -- 0 0 -- -- SPACE 8 5 SPARE 1 20 0 0 20 1 SPARE 6 3 FIRST LVL LIGHTING 1 20 220 425 20 1 LIGHTING 4 1 BASEMENT LIGHTING 1 20 1033 4510 20 1 INVERTER [1] 2 CKT DESCRIPTION P CB A B C CB P DESCRIPTION CKT PANEL NOTES: MCB RATING:-LOCATION:ELECTRICAL B07 VOLTAGE:480Y/277V, 3-PH MAINS TYPE:MLO FED FROM:MDP AIC RATING:22,000 GROUNDING BUS:Yes ENCLOSURE:NEMA 1 AMPACITY:225 A NEUTRAL BUS:100%MOUNTING:SURFACE PANEL: HBA PANEL CAPACITY:400 A SPARE CAPACITY:223 A DEMAND CURRENT:177 A DEMAND LOAD:147105 VA Motor 138105 VA 106.52% 147105 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS TOTAL CONNECTED LOAD:46035 VA 46035 VA 46035 VA 41 SPACE -- --0 0 -- -- SPACE 42 39 SPACE -- -- 0 0 -- -- SPACE 40 37 SPACE -- -- 0 0 -- -- SPACE 38 35 -- -- --583 0 -- -- SPACE 36 33 -- -- -- 583 0 -- -- SPACE 34 31 ESP-1 3 20 583 0 -- -- SPACE 32 29 -- -- --3333 167 -- -- -- 30 27 -- -- -- 3333 167 -- -- -- 28 25 UH-1 3 20 3333 167 20 3 SP-1 26 23 -- -- --12000 12000 -- -- -- 24 21 -- -- -- 12000 12000 -- -- -- 22 19 CU-2 3 50 12000 12000 50 3 CU-3 20 17 -- -- --0 11033 -- -- -- 18 15 -- -- -- 0 11033 -- -- -- 16 13 SPARE 3 20 0 11033 45 3 CU-1 14 11 -- -- --2106 433 -- -- -- 12 9 -- -- -- 2106 433 -- -- -- 10 7 KEF-1 3 15 2106 433 15 3 KEF-2 8 5 -- -- --1330 3048 -- -- -- 6 3 -- -- -- 1330 3048 -- -- -- 4 1 DOAS-1 3 15 1330 3048 30 3 MAU-1 2 CKT DESCRIPTION P CB A B C CB P DESCRIPTION CKT PANEL NOTES: MCB RATING:-LOCATION:ELECTRICAL B07 VOLTAGE:480Y/277V, 3-PH MAINS TYPE:MLO FED FROM:MDP AIC RATING:22,000 GROUNDING BUS:Yes ENCLOSURE:NEMA 1 AMPACITY:400 A NEUTRAL BUS:100%MOUNTING:SURFACE PANEL: HMA [1] DO NOT PROVIDE THIS CIRCUIT BREAKER. SHOWN ONLY TO CONNECT ASSUMED LOAD. PANEL CAPACITY:400 A SPARE CAPACITY:80 A DEMAND CURRENT:320 A DEMAND LOAD:115200 VA Equipment 115200 VA 100.00% 115200 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS TOTAL CONNECTED LOAD:38400 VA 38400 VA 38400 VA 83 84 81 82 79 80 77 78 75 76 73 74 71 72 69 70 67 68 65 66 63 64 61 62 59 60 57 58 55 56 53 54 51 52 49 50 47 48 45 46 43 44 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 -- -- --38400 6 3 -- -- -- 38400 4 1 ASSUMED LOAD [1] 3 20 38400 2 CKT DESCRIPTION P CB A B C CB P DESCRIPTION CKT PANEL NOTES:FUTURE PANEL TO BE PROVIDED IN KITCHEN TENANT FINISH. MCB RATING:-LOCATION:B.O.H. 104 VOLTAGE:208Y/120V, 3-PH MAINS TYPE:MLO FED FROM:LDP AIC RATING:10,000 GROUNDING BUS:Yes ENCLOSURE:NEMA 1 AMPACITY:400 A NEUTRAL BUS:100%MOUNTING:SURFACE PANEL: K1A PANEL CAPACITY:100 A SPARE CAPACITY:82 A DEMAND CURRENT:18 A Equipment 1000 VA 100.00% 1000 VA Receptacle 1440 VA 100.00% 1440 VA DEMAND LOAD:6595 VA Motor 4010 VA 103.62% 4155 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS TOTAL CONNECTED LOAD:2410 VA 2020 VA 2020 VA 41 SPARE 1 20 0 0 20 1 SPARE 42 39 SPARE 1 20 0 0 20 1 SPARE 40 37 SPARE 1 20 0 0 20 1 SPARE 38 35 SPACE -- --0 0 -- -- SPACE 36 33 SPACE -- -- 0 0 -- -- SPACE 34 31 SPACE -- -- 0 0 -- -- SPACE 32 29 SPACE -- --0 0 -- -- SPACE 30 27 SPACE -- -- 0 0 -- -- SPACE 28 25 EXT SOFFIT REC 1 20 180 0 -- -- SPACE 26 23 EXT SOFFIT REC 1 20 180 0 -- -- SPACE 24 21 EXT SOFFIT REC 1 20 180 0 -- -- SPACE 22 19 EXT SOFFIT REC 1 20 180 0 -- -- SPACE 20 17 EXT SOFFIT REC 1 20 180 500 20 1 SIGN PROVISION 18 15 EXT SOFFIT REC 1 20 180 500 20 1 SIGN PROVISION 16 13 EF-2 1 20 530 360 20 1 MAIN LEVEL RECEP 14 11 -- -- --290 290 -- -- -- 12 9 FCU-8 2 15 290 290 15 2 FCU-9 10 7 -- -- -- 290 290 -- -- -- 8 5 FCU-6 2 15 290 290 15 2 FCU-7 6 3 -- -- -- 290 290 -- -- -- 4 1 FCU-4 2 15 290 290 15 2 FCU-5 2 CKT DESCRIPTION P CB A B C CB P DESCRIPTION CKT PANEL NOTES: MCB RATING:-LOCATION:B.O.H. 104 VOLTAGE:208Y/120V, 3-PH MAINS TYPE:MLO FED FROM:LDP AIC RATING:10,000 GROUNDING BUS:Yes ENCLOSURE:NEMA 1 AMPACITY:100 A NEUTRAL BUS:100%MOUNTING:SURFACE PANEL: L1A PANEL CAPACITY:150 A Appliance - Commercial 1700 VA 100.00% 1700 VA SPARE CAPACITY:87 A Lighting 2760 VA 125.00% 3450 VA DEMAND CURRENT:63 A Equipment 1050 VA 100.00% 1050 VA Receptacle 5520 VA 100.00% 5520 VA DEMAND LOAD:22622 VA Motor 9877 VA 110.38% 10902 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS TOTAL CONNECTED LOAD:5080 VA 8240 VA 7587 VA 41 EF-1 1 20 1587 180 20 1 BAR POS 42 39 MAU CONTROL PANEL 1 20 1200 1200 20 1 BAR DISHWASHER 40 37 IBT HEATER (DOAS) 1 20 1200 500 20 1 BAR FRIG BAR 38 35 -- -- --450 0 -- -- SPACE 36 33 BRANCH SEL BOXES 2 15 450 0 -- -- SPACE 34 31 SPARE 1 20 0 0 -- -- SPACE 32 29 -- -- --2050 200 20 1 DWH-1 30 27 AC-1 2 20 2050 180 20 1 DCP-1 28 25 LTG BSMT RESTROOM 1 20 840 350 20 1 SUMP PUMP CONTROL 26 23 LTG BSMT LOBBY 1 20 760 350 20 1 FLUE FAN CONTROL 24 21 LTG BSMT LOBBY 1 20 1160 350 20 1 SNOWMELT CONTROL 22 19 REC ROOF 1 20 180 180 20 1 REC GLYCOL FEED 20 17 -- -- --185 200 20 1 CP-1 18 15 FCU-3 2 15 185 200 20 1 B-1 16 13 -- -- -- 185 200 20 1 CP-2 14 11 FCU-2 2 15 185 720 20 1 REC MECH 12 9 -- -- -- 185 180 20 1 REC CONDENSORS 10 7 FCU-1 2 15 185 180 20 1 WEST REC RM B03 8 5 REC JAN & RESTRM 1 20 540 180 20 1 EAST REC RM B03 6 3 REC BSMNT 1 20 900 0 20 1 SPARE 4 1 REC ELEV SHAFT TOP 1 20 540 540 20 1 RECPTS RM B02A 2 CKT DESCRIPTION P CB A B C CB P DESCRIPTION CKT PANEL NOTES: MCB RATING:150 A LOCATION:ELECTRICAL B07 VOLTAGE:208Y/120V, 3-PH MAINS TYPE:MCB FED FROM:XLBA AIC RATING:10,000 GROUNDING BUS:Yes ENCLOSURE:NEMA 1 AMPACITY:225 A NEUTRAL BUS:100%MOUNTING:SURFACE PANEL: LBA [1] DO NOT PROVIDE THIS CIRCUIT BREAKER. SHOWN ONLY TO CONNECT ASSUMED LOAD. PANEL CAPACITY:150 A SPARE CAPACITY:73 A DEMAND CURRENT:77 A Equipment 27000 VA 100.00% 27000 VA DEMAND LOAD:27720 VA Receptacle 720 VA 100.00% 720 VA LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR DEMAND LOAD TOTALS TOTAL CONNECTED LOAD:9360 VA 9360 VA 9000 VA 41 SPARE 1 20 0 0 20 1 SPARE 42 39 SPARE 1 20 0 0 20 1 SPARE 40 37 SPARE 1 20 0 0 20 1 SPARE 38 35 SPARE 1 20 0 0 20 1 SPARE 36 33 SPARE 1 20 0 0 20 1 SPARE 34 31 SPARE 1 20 0 0 20 1 SPARE 32 29 SPACE -- --0 0 -- -- SPACE 30 27 SPACE -- -- 0 0 -- -- SPACE 28 25 SPACE -- -- 0 0 -- -- SPACE 26 23 SPACE -- --0 0 -- -- SPACE 24 21 SPACE -- -- 0 0 -- -- SPACE 22 19 SPACE -- -- 0 0 -- -- SPACE 20 17 SPACE -- --0 0 -- -- SPACE 18 15 SPACE -- -- 0 0 -- -- SPACE 16 13 SPACE -- -- 0 0 -- -- SPACE 14 11 SPACE -- --0 0 -- -- SPACE 12 9 SPACE -- -- 0 0 -- -- SPACE 10 7 SPACE -- -- 0 0 -- -- SPACE 8 5 SPACE -- --0 9000 -- -- -- 6 3 REC THEATER 1 20 360 9000 -- -- -- 4 1 REC STAGE 1 20 360 9000 100 3 ASSUMED LOAD [1] 2 CKT DESCRIPTION P CB A B C CB P DESCRIPTION CKT PANEL NOTES: MCB RATING:150 A LOCATION:B.O.H. B02A VOLTAGE:208Y/120V, 3-PH MAINS TYPE:MCB FED FROM:LDP AIC RATING:10,000 GROUNDING BUS:Yes ENCLOSURE:NEMA 1 AMPACITY:150 A NEUTRAL BUS:100%MOUNTING:SURFACE PANEL: LBT 1 1 1 1 7 ASI 07 REVISION DATE ADDENDUM 1 07/14/2020 ASI 07 03/17/2021 03/17/21 © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 4 : 1 4 P M P-002 PLUMBING SCHEDULES St a n l e y H o t e l C a r r i a g e H o u s e REG 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS PBM BCER PROJECT 89319007 PLUMBING FIXTURE SCHEDULE PLAN CODE DESCRIPTION LOCATION FIXTURE FLUSH VALVE / FAUCET GPF/GPM FIXTURE MOUNTING HEIGHT A.F.F. REMARKS MFGR. MODEL MOUNTING STYLE FIXTURE INSTALLED MFGR. MODEL FIXTURE INSTALLED STYLE MFGR. MODEL MFGR. MODEL WC-1 WATER CLOSET - STANDARD PUBLIC TOILET ROOMS KOHLER K-4323 WALL SLOAN CX 8158-1.28-GR-OR SENSOR 1.28 STANDARD (7)(11) PROVIDE COLOR BLACK WC-2 WATER CLOSET - STANDARD PUBLIC TOILET ROOMS KOHLER K-4325 WALL SLOAN CX 8158-1.28-GR-OR - 1.28 STANDARD (7)(11) PROVIDE COLOR BLACK UR-1 URINAL - STANDARD PUBLIC TOILET ROOMS KOHLER K-5452-ER WALL SLOAN CODE #34532004 SENSOR 0.125 STANDARD (7)(11) PROVIDE COLOR BLACK UR-2 URINAL - ADA PUBLIC TOILET ROOMS KOHLER K-5452-ER WALL SLOAN CODE #34532004 SENSOR 0.125 STANDARD (7)(11) PROVIDE COLOR BLACK L-1 LAVATORY - ADA PUBLIC TOILET ROOMS KOHLER K-3202 COUNTER MAC FAUCETS FA43-129 SINGLE HANDLE 0.5 - (5)(6)(10) 4" CENTERS L-2 LAVATORY - STANDARD RE: PLANS KOHLER K-2196-4 COUNTER CHICAGO 802-E70-1000ABCP HANDLE 0.5 RE: ARCH DWGS PROVIDE WITH TMV-1. MSB-1 MOP SERVICE BASIN JANITORS CLOSET FIAT MSB 2424 FLOOR CHICAGO 897-CRCF MANUAL - - - WB-1 WALL BOX RE: PLANS SIOUX CHIEF 696-3 WALL PROVIDE WITH SECONDARY DRAIN FUNNEL HB-1 HOSE BIBB - - WALL CHICAGO 998-XKRCF LEVER - RE: ARCH DWGS AD-1 FLOOR DRAIN FINISHED AREAS J.R. SMITH 2110 FLOOR (12) FD-1 FLOOR DRAIN FINISHED AREAS J.R. SMITH 2005Y FLOOR (1)(4) FD-2 FLOOR DRAIN FINISHED AREAS J.R. SMITH 2005Y-B FLOOR (1)(8) FS-1 FLOOR SINK MECH ROOM JAY R. SMITH 3150T-CI-12 FLOOR (1)(2)(9) DSN-1 DOWNSPOUT NOZZLE EXTERIOR LOCATIONS J.R. SMITH 1770 WALL OFD-1 OVERFLOW DRAIN ROOF J.R. SMITH 1070 ROOF (3) RD-1 ROOF DRAIN ROOF J.R. SMITH 1010 ROOF (3) (6) PROVIDE TRUEBRO INSULATION KIT ON ALL EXPOSED PIPING.(12) PROVIDE WITH FLAT BOTTOM STRAINER. (5) PROVIDE OPEN GRID STRAINER.(11) PROVIDE WITH SHOCK ARRESTER WHERE INDICATED ON ISOMETRIC. (4) ROUND NICKEL BRONZE STRAINER.(10) PROVIDE WITH 0.5 GPM AERATOR. (3) PROVIDE WITH CAST IRON DOME STRAINER, UNDERDECK CLAMP, SUMP RECEIVER.(9) PROVIDE WITH BOTTOM DOME STRANER. (2) PROVIDE WITH NICKEL BRONZE 1/2 GRATE, CAST IRON INTERIOR.(8) PROVIDE WITH SEDIMENT BUCKET. (1) PROVIDE WITH TRAP SEAL DEVICE ASSE 1072 APPROVED.(7) PROVIDE COMMERCIAL GRADE CARRIER WITH FEET SECURELY BOLTED TO THE FLOOR AND ALL FIXTURE MOUNTING ACCESSORIES. PLUMBING FIXTURE CONNECTION SCHEDULE FIXTURE TYPE SYMBOL MIN. TRAP SIZE SOIL OR WASTE VENT (1) COLD WATER HOT WATER REMARKS WATER CLOSET WC - 4" 2" 1" - (3)(4) PROVIDE COLOR BLACK WATER CLOSET - ADA WC - 4" 2" 1/2" - (3)(4) PROVIDE COLOR BLACK URINAL UR - 2" 2" 3/4" - LAVATORY L 1-1/4" 2" 2" 1/2" 1/2" MOP SERVICE BASIN MSB 3" 3' 2" 1/2" 1/2" (2) 2" MINIMUM WASTE BELOW GRADE. (4) ADA ACCESSIBLE W.C. - LOCATE FLUSH VALVE HANDLE ON WIDE SIDE OF STALL. HANDLE SHALL MEET ADA REQUIREMENTS. (1) 2" MINIMUM VENT BELOW GRADE. (3) PROVIDE SHOCK ARRESTOR ON COLD WATER SUPPLY W/ ACCESS DOOR. BACKFLOW PREVENTER ASSEMBLY SCHEDULE PLAN CODE TYPE SYSTEM MFGR. MODEL INSTALLED QUANTITY LINE SIZE (INCHES) PRESSURE DROP (PSIG) MIN. FUNNEL DRAIN SIZE REMARKS MFGR. MODEL BFP-1 HORIZONTAL REDUCED PRESSURE DOMESTIC WATER WILKINS FICS 1 2-1/2 14 - (1)(2)(3)(5)(6) BFP-2 COMPACT REDUCED PRESSURE IRRIGATION WILKINS 975XL2 1 1-1/2 12 - (1)(3)(4)(6) BFP-3 COMPACT REDUCED PRESSURE EVAP COOLER WILKINS 975XL2 1 1 12 - (1)(3)(4)(6) (3) PROVIDE TESTING AND CERTIFICATION IN ACCORDANCE WITH COLORADO REQUIREMENTS. (6) REFER ALSO TO DETAIL. (2) ASSEMBLY PROVIDED WITH SHUTDOWN DEVICE.(5) PROVIDE FUNNEL WITH FULL SIZE DRAIN TO FLOOR SINK. (1) COMPLETE ASSEMBLY WITH VALVES, FULL LINE SIZE.(4) PROVIDE WITH BALL VALVE AND UNION. DOMESTIC WATER EXPANSION TANK SCHEDULE PLAN CODE MFGR. MODEL INSTALLED SERVICE CHARGE PRESSURE ACCEPT. VOLUME (GAL.) TOTAL VOLUME (GAL.) OPERATING WEIGHT (LBS.) WATER VOLUME (GAL.) REMARKS MFGR. MODEL DET-1 THERM-X-TROL ST-30VC DOM. HOT WATER 80 9.0 14 134 119 (1) (1) FLOOR MOUNTED TYPE. GAS DOMESTIC WATER HEATER SCHEDULE (CLOSED COMBUSTION) PLAN CODE MFGR. MODEL NO. SERVICE/LOC ATION INSTALLED CAPACITY (GALLONS) DIM. DIA.xH RECOVER IN GPH @ 80 DEG. TEMP. @ S.L. MBH INPUT @ S.L. EFFICIENCY (%) GAS TYPE GAS CONN. (IN) MIN. GAS PRESSURE (IN. W.C.) MAX GAS PRESSURE )IN. W.C.) FLUE CONN. (IN. W.C.) (8) COMBUSTION AIR INLET (IN. DIA.) REMARKS MFGR. MODEL NO. DWH-1 AO SMITH BTH-500 DOM. HOT WATER 119 33"x76" 576 500 95 NATURAL GAS 1-1/2" 4.8" 14" 4 4 (1)(2)(3)(4)(5)(6) (3) FACTORY INSTALLED T&P VALVE.(6) COORDINATE SPECIAL FLUE REQUIREMENTS WITH MFG. (2) ET-1, EXPANSION TANK; SEE PLAN FOR SIZE.(5) PROVIDE GAS PRESSURE REGULATOR UPSTREAM OF UNITS; MINIMUM OF 5" W.C. & 14 W.C. MAXIMUM GAS TO UNIT. (1) SET MAXIMUM HOT WATER DISCHARGE TEMP. TO 140°F.(4) ASTM STAMPED. (OVER 190 MBH OR 119 GALLON) SUMP PUMP SCHEDULE PLAN CODE MFGR. MODEL INSTALLED GPM TOTAL CAPACITY HEAD BASIN HP VOLT/PH REMARKS MFGR. MODEL ESP-1 WEIL 1413 50 25 - 1.0 480/3 (2) SP-1 WEIL 1418 40 28 30"x60" 1.0 480/3 (1) (2) PROVIDE WITH OIL DETECTION SYSTEM. (1) PROVIDE SIMPLEX PUMP SYSTEM, CONTROL PANEL, WITH EXTRA SET OF DRY CONTACTS FOR CONNECTIONS TO BAS. PROVIDE HIGH WATER ALARM (AUDIBLE) AND LIGHT. PROVIDE 3 FLOAT SYSTEM. ALL COMPONENTS TO BE COMPATIBLE. THERMOSTATIC MIXING VALVE SCHEDULE PLAN CODE MFGR. MODEL INSTALLED SERVICE MINIMUM FLOW (GPM) FLOW (GPM) @ 10 PSI P.D. INLET TEMP. °F OUTLET TEMP. °F ASSE STANDARD REMARKS MFGR. MODEL TMV-1 LEONARD 170A-LF POINT OF USE 0.25 1.25 140 110 1070 (1)(2) (2) ALL MIXING VALVES TO HAVE CHECK VALVES ON BOTH HOT AND COLD SUPPLIES. SOME UNITS HAVE INTEGRAL CHECK VALVES. VERIFY EACH LOCATION HAS CHECK VALVES. (1) LOCATE IN ACCESSIBLE LOCATION OR PROVIDE ACCESS DOOR. WATER HAMMER ARRESTER SCHEDULE PLAN CODE FIXTURE UNIT RATING P.D.I. SIZE ARRESTOR THROAT SIZE REMARKS SA-4 61-113 D 1-1/4" (1) (1) PROVIDE ISOLATION VALVE ON SUPPLY PIPING TO SHOCK ARRESTER. DOMESTIC CIRCULATING PUMP SCHEDULE PLAN CODE MFGR. MODEL INSTALLED SERVICE/LOCATION FLANGE SIZE CAPACITY (GPM) HEAD FT. WATER MOTOR REMARKS MFGR. MODEL HP (EACH) VOLTS/PH DCP-1 GRUNDFOS 32-100 F N MECH ROOM 3/4" 2.0 30 178 W 115/1 (1)(2)(3)(4) (2) PROVIDE ON/OFF WALL SWITCH.(4) PROVIDE TIMER FOR UNOCCUPIED SHUTDOWN. (1) LEAD FREE BRONZE OR STAINLESS STEEL PUMP. PROVIDE AQUASTAT CONTROLLER. (3) SET CONTROL MODE TO AUTO ADAPT. ASI-02 07 ASI 07 ASI REVISION DATE ASI-02 05.22.2020 ASI-07 03.17.2021 03/17/21 M BFP DCP-1 BFP SA-4 4 3 2 1 AC DE 2"PD UP SP-1 3"SD 4"BD 4"W UP TO WCO 2"V UP 3"W UP TO MSB 2"W UP TO FD2"W UP TO FD 2"V UP 3"SD UP TO AD 3"SD UP TO AD 3"SD 3"SD 3"SD UP TO AD IE=83.47' P-501 1 2"W UP TO UR 2"W UP TO UR 3"W UP TO FD 3"W UP TO FS 2"V UP 4"W UP TO FS 4"BD 2"V UP4"W UP TO FS 4" B D 2"W DN P7 ESP-1ESP-1 2"PD UP B IE=85.96' IE=85.10' P1 IE=85.50' P17 P24 3"W UP TO FS IE=84.23' IE=86.50' 2"V UP 3"SD 3"SD UP TO FCO 3"SD UP TO FCO 3" S D 4"BD 4"BD 4"BD 4"W UP 3"W UP 3"W UP 3"W UP 4" B D 3"BD 2"V UP P31 4"BD P32 07 ASI P-501 6 2"W UP 4"W UP 3"W UP 2"W UP 4"W UP 4"BD4"BD 2" B D © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 4 : 1 6 P M P-100 UNDERGROUND PLUMBING PLAN St a n l e y H o t e l C a r r i a g e H o u s e REG 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS PBM BCER PROJECT 89319007 N 0 8'8' 4' 1/4" = 1'-0" 1 UNDERGROUND PLUMBING PLAN 2. BUILDING AND STORM DRAIN TO BE SLOPED AT 1/8"/FT. 1. GREASE WASTE TO BE SLOPED AT 1/4"/FT. GENERAL NOTES WORK NOTES P1 REFER TO CIVIL DRAWINGS FOR CONTINUATION. P7 BACKWATER VALVE, JR SMITH MODEL 7012 OR EQUAL, SUPPORT FROM BASE. PROVIDE 48"ØX4'-0" DEEP FIBERGLASS BASIN AS MANUFACTURED BY TOPP INDUSTRIES, OR EQUAL. REFER TO DETAIL NO. 4 ON SHEET P-602 FOR ADDITIONAL INFORMATION. P17 SD TOP OF PIPE = 84.90', BD INVERT = 85.32'. P24 ESP-1, ELEVATOR SUMP PUMP. REFER TO DETAIL NO. 3 ON SHEET P-602 FOR ADDITIONAL INFORMATION. P31 PROVIDE SLEEVE THROUGH STEM WALL. P32 CIVIL TO PROVIDE PROVIDE 4" TWO-WAY GCO IN PARKING AREA TO THE EAST. ASI-01 ASI-02 ASI-02 ASI-02 REVISION DATE ASI-01 05.15.2020 ASI-02 05.22.2020 ASI-07 03.17.2021 03/17/21 L-1 MSB-1 UR-1 UR-2 WC-1 WC-1 WC-1WC-1 WC-2 WC-2 M BFP DET-1 TMV-1 TMV-1 DCP-1 BFP SA-4 TMV-1 MSB-1 WB-1 L-2 WC-2 4 3 2 1 AC DE 2"FD-12"FD-1 2"FD-12"FD-1 4" G W 4"GW DN BFP-2 SP-1 P5 3"FD-23"FD-2 3" 3/4"2" 2 1/2" P6 P4 2"V DN 1/2" 2" 3"AD-13"AD-1 3"AD-13"AD-1 3"AD-13"AD-1 P-501 1 P-501 2 MAU-1 DOAS-1 IE=92.00' 4"FS-14"FS-1 G G G P8 P11 P10 BFP-1 P9 3"FS-13"FS-1 2"V DN IE=95.00' P1 2"PD DN PD 2" IE=98.00' P12 4"SD 1 1/2" G G 2"V DN TI STORAGE B08 LOUNGE B02 LOBBY B01 BAR B03 B.O.H. B02A ELECTRICAL B07 LOBBY B01 1 1/4" 4"W DN P5 2"PD DN PD BFP-3 P1 P14 P15 DWH-1 P16 B P18 2" 3" P21 B-1 HB-1 3/4"CW DN 2"V DN 3"FS-13"FS-1 2" 2" P25 2" TI STORAGE B08 G G G 4" 4" 1 1/4" 4"G UP P1 P1 3"SD UP P1 LCO P1 P30 P29 P23 4"FS-14"FS-1 P15 3"FCO3"FCO 3"FS-13"FS-1 4"FCO4"FCO 2"V DN 3"FD-13"FD-1 IE=92.00' P20 P1 4"LCO 4"SD UP 4"SD UP TMV-1 P28 P34 P33 4"WCO SA-1TMV-1 P13 P19 (3)WB-1 P-501 6 P-501 5 2"V 2"V 2"V 2"CW 1 1/4"HW 1/2"HWC 07 ASI © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 4 : 1 9 P M P-200 BASEMENT PLUMBING PLAN St a n l e y H o t e l C a r r i a g e H o u s e REG 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS PBM BCER PROJECT 89319007 1. GREASE WASTE PIPING TO BE SLOPED AT 1/4"/FT. GENERAL NOTES N 0 8'8' 4' 1/4" = 1'-0" 1 BASEMENT PLUMBING PLAN WORK NOTES P15 REFER TO ISOMETRIC NO. 3 ON SHEET P-501 FOR PIPING ARRANGEMENT OF WATER METER, PRESSURE REDUCING VALVE, AND BACKFLOW PREVENTERS. P16 KEEP GREASE WASTE PIPING AS LOW AS POSSIBLE AT THIS POINT TO ALLOW FOR 1/4"/FT SLOPE FROM THE KITCHEN. P18 1-1/4"G CAPPED FOR FUTURE EXTENSION TO PATIO FIREPIT. P19 ROUTE DRAIN PIPE FROM GLASSWASHER TO WB-1. P20 CIVIL TO PROVIDE PROVIDE 4" TWO-WAY GCO WITHIN 5'-0" OF THE SOUTH EDGE OF THE PATIO AREA. P21 SP-1, SUMP PUMP CONTROL PANEL. REFER TO DETAIL NO.1 ON SHEET P-602 FOR ADDITIONAL SUMP PUMP INFORMATION. P23 REFER TO GAS WATER HEATER DETAIL NO. 4 ON SHEET P-602 FOR VALVES AND ADDITIONAL INFORMATION. P25 REFER TO WATER HEATER DETAIL FOR CW, HW, HWC ROUTING FROM THIS POINT. PROVIDE SHUTOFF VALVE ON CW AT TAKEOFF FROM MAIN. P28 SET TO 0.5 GPM. P29 (2) 2"VENT FROM GREASE INTERCEPTOR. P30 (2) 2"VENT UP, DO NOT COMBINE UNTIL 42" MINIMUM ABOVE FINISHED FLOOR. P33 3/4"HW/CW DOWN, ROUTE 1/2"HW/CW TO HANDSINK AND LAVATORY. P34 1/2"HW DOWN TO SERVE GLASSWASHER. WORK NOTES P1 REFER TO CIVIL DRAWINGS FOR CONTINUATION. P4 CAP FOR FUTURE EXTENSION. P5 TRANSITION 2"PD TO 4"W GRAVITY DRAIN AT THIS POINT. P6 3"V, 2"CW, 2"HW, 1/2"HWC UP. P8 1"G DOWN TO BOILER. CONTRACTOR TO COORDINATE GAS CONNECTION LOCATION OF UNIT AND ROUTE PIPING ACCORDINGLY. TERMINATE WITH SHUTOFF VALVE, UNION AND 6" DIRT LEG. P9 2"G DOWN TO WATER HEATER. CONTRACTOR TO COORDINATE GAS CONNECTION LOCATION OF UNIT AND ROUTE PIPING ACCORDINGLY. TERMINATE WITH SHUTOFF VALVE, UNION AND 6" DIRT LEG. P10 3"G DOWN TO MAKEUP AIR UNIT. CONTRACTOR TO COORDINATE GAS CONNECTION LOCATION OF UNIT AND ROUTE PIPING ACCORDINGLY. TERMINATE WITH SHUTOFF VALVE, UNION AND 6: DIRT LEG. P11 2"G DOWN TO DEDICATED OUTDOOR AIR SYSTEM. CONTRACTOR TO COORDINATE GAS CONNECTION LOCATION OF UNIT AND ROUTE PIPING ACCORDINGLY. TERMINATE WITH SHUTOFF VALVE, UNION AND 6" DIRT LEG. P12 REFER TO IRRIGATION DRAWINGS FOR CONTINUATION. P13 1-1/2"W FROM EACH SINK COMPARTMENT TO BE INDIVIDUALLY ROUTED TO WB-1. P14 REFER TO FIRE PROTECTION DRAWINGS FOR CONTINUATION. ASI-01 ASI-02 ASI-02 07 ASI 07 ASI 07 ASI 07 ASI REVISION DATE ASI-01 05.15.2020 ASI-02 05.22.2020 ASI-07 03.17.2021 03/17/21 2" 4"4" 4"4" 2" 4"WCO 4"WCO 4"WCO WC-2 WC-2 UR-2 UR-1 L-1 L-1 L-1 L-1 2"WCO 2"WCO WC-1 WC-1 WC-1 WC-1 2"FD-1 2"FD-1 2"WCO 2"WCO 2"2" 2" 2" 2" 2" 2" 2" 2" 2" 3" 2" 2" 2" 2" 2" 4" 4" 3" 3" WC-2 WC-2 UR-2 UR-1 L-1 L-1 L-1 L-1 WC-1 WC-1 WC-1 WC-1 2"HEADER SA-4 2"HEADER 1/2" 1" 2" MSB-1 3/4" 2-1/2" 1" 1-1/2" TO IRRIGATION TO MAU-1 BFP-3 BFP-2 BFP-11" 2" TO BLDG 2" WATER METER, COORDINATE TYPE AND MODEL WITH ESTES PARK WATER DISTRICT STRAINER ACV PRESSURE REDUCING VALVE, ZURN MODEL ZW209BP. SET AT 95 PSI. NOTES: REFER TO DETAIL NO. 5 ON SHEET P-601 FOR ADDITIONAL VALVES AND INFORMATION FOR BFP-1 REFER TO DETAIL NO. 6 ON SHEET P-601 FOR ADDITIONAL VALVES AND INFORMATION FOR BFP-2 REFER TO DETAIL NO. 2 ON SHEET P-602 FOR ADDITIONAL VALVES AND INFORMATION FOR BFP-3 IRRIGATION TO BE OPERATED AT OFF PEAK RESTAURANT HOURS 2-1/2" 2" 1-1/2" TO CITY MAIN M BSMT LVL (F)KITCHEN 2500 MBH 3113.3 CFH (ESTIMATE) GAS METER SET BY EXCEL ENERGY, SET PRESSURE TO 10" W.C. (4904.5 MBH) (6107.7 CFH) 3" 2" MAU-1 1055 MBH 1313.8 CFH DOAS-1 444 MBH 553.7 CFH 4"1-1/4" (F)FIRE PIT 200 MBH 249.1 CFH (ESTIMATE) 4" (F)FIREPLACE 60 MBH 74.7 CFH (ESTIMATE) (F)FIREPLACE 60 MBH 74.7 CFH (ESTIMATE) 4" 4" 3/4"B-1 85 MBH 105.9 CFH 2" DWH-1 500 MBH 622.5 CFH 4" ALL GAS CONNECTIONS TO BE HARD TYPE WITH SHUTOFF VALVE, UNION AND 6" DIRT LEG 5" L-2 HANDSINK 3-COMP SINK WC-2 GLASSWASHER 1" 1/2"HWC 2"CW SA-1 TMV-1 TMV-1 1/2"HW 1-1/4"HW 3/4"3/4" 1/2" 0.5 GPM 4"WCO L-2 HANDSINK 3-COMP SINK (3)WB-1 WC-2 WB-1 4"W 4"W 4"W 2"W 3"W 2"V 2"V © Copyright BCER Engineering ALL DRAWINGS, SPECIFICATIONS, AND OTHER WORK PRODUCT PREPARED BY BCER ENGINEERING FOR THIS PROJECT ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF BCER ENGINEERING. BCER ENGINEERING SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF MOA ARCHITECTURE 3/ 1 7 / 2 0 2 1 5 : 3 4 : 1 9 P M P-501 PLUMBING ISOMETRICS St a n l e y H o t e l C a r r i a g e H o u s e REG 2020.05.04 19131.00 33 3 E W o n d e r v i e w A v e E s t e s P a r k , C O 8 0 5 1 7 100% CONSTRUCTION DOCUMENTS PBM BCER PROJECT 89319007 NOT TO SCALE 1 TOILET ROOM WASTE/VENT ISOMETRIC NOT TO SCALE 2 TOILET ROOM DOMESTIC WATER ISOMETRIC NOT TO SCALE 3 BACKFLOW PREVENTER ARRANGEMENT ISOMETRIC NOT TO SCALE 4 GAS PIPING SCHEMATIC ADD 1 6.00 14400 0.99 14256.00 5.00 8880 0.99 8791.20 4.00 4910 0.99 4860.90 3.00 2410 0.99 2385.90 2.50 1360 0.99 1346.40 2.00 854 0.99 845.46 1.50 443 0.99 438.57 1.25 296 0.99 293.04 1.00 144 0.99 142.56 0.75 77 0.99 76.23 0.5 175 P.D. L.F. Pipe Size (inch) Pipe capacity CFH Based... Specific Gravity Factor Actual CFH Low Pressure Pipe Sizing Chart - 2018 IFGC Table402.4(2) Total Equivalent Length:172.5 Lineal Feet Equivalent Length Factor:X 1.5 Measured Distance of Pipe: 115 Total CFH:6,107.7 CFH Gas Heating Value:803 BTU/CF (3) Total BTUH:4,904,500 Totals 4,904,500 0 0 6"-8" 0 0 0 6"-8" 0 1 KITCHEN 2500 6"-8" 2,500,000 1 FIRE PIT 200 6"-8" 200,000 1 FIREPLACE - EXTERIOR 60 6"-8" 60,000 1 FIREPLACE - INTERIOR 60 6"-8" 60,000 1 DWH-1 500 6"-8" 499,900 1 B-1 85 6"-8" 85,000 1 MAU-1 1055 6"-8" 1,055,000 1 DOAS-1 445 6"-8" 444,600 Quantity Equipment MBH/Unit @ S.L. Required W.C. Total BTUH Gas Heating Value 803 BTU/CF Specific...0.61 Natural Gas Sizing For Building Mains - Low Pressure ADD 2 ADD 2 NOT TO SCALE 5 DOMESTIC WATER ISOMETRIC - BAR AND BOH NOT TO SCALE 6 SANITARY WASTE AND VENT ISOMETRIC - BAR AND BOH 07 ASI REVISION DATE ADDENDUM 1 07.15.2020 ADDENDUM 2 07.22.2020 ASI-07 03.17.2021 03/17/21