Loading...
HomeMy WebLinkAboutPLANS Deck 409 Pawnee Ln 2023-06-075/9/23 5/9/23 5/9/23 5/9/23 Hurd Deck Expansion and Remodel Notes Applicable Codes – but not limited to 2015 IRC Structural Notes General 1. 68 PSF ground snow load and deck load 2. 173 MPH Vult wind speed Footings, foundations and slabs 1. Sized assuming standard soils with 2500 pounds per square foot bearing capacity (without having actual soils borings or soil testing). 2. Concrete to be 3000 PSI mix for foundations and 3500 PSI for slabs. 3. All rebar to be 60 ksi steel and minimum 2” clear to concrete edge or 3” to bottom of footing 4. Cast-in anchors shall be in accordance with ASTM F1554 Grade 36 or equivalent with ASTM A563 Grade A nuts, and ASTM F436 washers. All parts to be hot dipped galvanized in accordance with ASTM A153 or ASTM F2329. 5. Excavation contractor to assure that all footing is placed on undisturbed soil. 6. Piers shall have 30” minimum embedment from final grade to bottom of footing. General 1. Provide temporary bracing to withstand all construction, snow and wind loads until all field connections are completed Framing 1. All new deck framing wood to be #2 Hem Fir treated or better. 2. Within joist cavities beneath solid or built-up columns provide squash blocking of area equivalent to the columns above. 3. Fasten wood members with common nails according to the requirements listed in the IBC fastening Schedule Table 2304.9.1. Anchor engineered joist and pre-engineered trusses per the manufacturer’s requirements. 4. All OSB wall sheathing to be installed horizontally, with end joints offset a minimum of 32”, attached with 8d nails at 6” o.c. at edges and 12” o.c. in the field. 5. Fasten 19/32” roof sheathing with 8d nails at 6” o.c. at edges and 12” o.c. in the field Provide the following Simpson connectors at the noted locations: 1. 6 x 6 post to a concrete pier – ABA66Z 2. Rafter tie to wall – H3 3. 2 x 10 joist hanger – LU210 4. 6 x 6 post to a 6 x beam – PC66-16 6.5.23 Windows All door/windows sizes shown are based on existing size. All door/new window are tempered. All new windows are aluminum clad wood window. All windows are minimum U .30 or better. General Notes 1. All new 2 x deck framing to be treated lumber for exterior exposure. 2. Decking surface to be thermoplastic composite lumber with ASTM E84 flame spread index less than 200. 3. Gravel under deck and 2‘beyond drip line of deck to be ¾” minimum washed rock, 2” thick over landscape barrier over weed barrier. Electrical 1. Provide remote control fan for new fan under new deck roof. 2. Provide 4 LED can downlights in ceiling of new deck roof.