HomeMy WebLinkAboutSITE PLAN New SFD 1877 Ptarmigan Trl 2020-04-09# OF BARS, E.W.PAD SIZE
13" - 18"3 - #4 REBAR
19" - 24" 4 - #4 REBAR
25" - 30" 5 - #4 REBAR
31" - 36" 6 - #4 REBAR
37" - 42"7 - #4 REBAR
NOTE: CONTRACTOR TO VERIFY
ALL DIMENSIONS PRIOR TO
CONSTRUCTION. AN OPEN HOLE
OBSERVATION IS REQUIRED.
= SIMPSON STHD14
SHOWN AT APPROXIMATE LOCATION
FO
U
N
D
A
T
I
O
N
P
L
A
N
LATERAL LOAD DESIGN CHART
- ANY HEADERS OR COLUMNS SHOWN ON THIS PLAN SUPERSEDE THIS CHART.
- ANY HEADERS THAT WILL BE BEARING BEAMS OR GIRDER TRUSSES THAT ARE
NOT SHOWN ON THIS PLAN SHOULD BE BROUGHT TO THE ATTENTION OF THE
ENGINEER. HEADERS MAY NOT BE DESIGNED TO SUPPORT GIRDER TRUSS, OR
OTHER, POINT LOADS.
-NON BEARING HEADERS COULD BE 2-2x10 HF, OR BETTER (1T, 1K)
UP TO 4'-6"(2) 2x12 HF#2 OR BETTER
OPENING SIZE MIN. HEADER SIZE 2x TRIMMERS 2x KINGS
1 1
OVER 4'-6" UP TO 8'-0"(2) 912" ML OR BETTER 2 2
MAIN FLOOR HEADER CHART
NOTE: ALL EXTERIOR SHEAR WALLS
ARE TYPE TYP. U.N.O. REFER TO
LATERAL LOAD DESIGN CHART. NO
INTERIOR WALLS ARE DESIGNED AS
SHEAR WALLS.
A
NOTE: THIS SHEAR WALL DESIGN
SUPERCEDES BRACED WALL DESIGN.
BEAM TO POST CONNETION DETAIL
SCALE: N.T.S.
POST BASEPOST CAPPOST SIZE
INSTALL PER MANUFACTURERS SPECIFICATIONS
ABU88ZPC8Z8x8
SIMPSON, OR EQUAL, POST BASE/CAP INSTALLATION DETAIL
SCALE: N.T.S.
UP
P
E
R
F
L
O
O
R
A
N
D
L
O
W
E
R
RO
O
F
F
R
A
M
I
N
G
P
L
A
N
GENERAL NOTES
FOUNDATION WALL DETAIL
SCALE: N.T.S.
EXTERIOR PAD DETAILINTERIOR PAD DETAIL
SCALE: N.T.S.SCALE: N.T.S.
PORTAL FRAME DETAIL
SCALE: N.T.S.
OVER CONCRETE OR MASONRY BLOCK FOUNDATION
OVER RAISED WOOD FLOOR - FRAMING ANCHOR OPTION
(WHEN PORTAL SHEATHING DOES NOT LAP OVER RIM JOIST)
INTERIOR FRAME WALL/FOOTING DETAIL
SCALE: N.T.S.
ROOF BEAM TO POST CONNETION DETAIL
SCALE: N.T.S.
LATERAL LOAD DESIGN CHART
- ANY HEADERS OR COLUMNS SHOWN ON THIS PLAN SUPERSEDE THIS CHART.
- ANY HEADERS THAT WILL BE BEARING BEAMS OR GIRDER TRUSSES THAT ARE
NOT SHOWN ON THIS PLAN SHOULD BE BROUGHT TO THE ATTENTION OF THE
ENGINEER. HEADERS MAY NOT BE DESIGNED TO SUPPORT GIRDER TRUSS, OR
OTHER, POINT LOADS.
-NON BEARING HEADERS COULD BE 2-2x10 HF, OR BETTER (1T, 1K)
UP TO 4'-6"(2) 2x12 HF#2 OR BETTER
OPENING SIZE MIN. HEADER SIZE 2x TRIMMERS 2x KINGS
1 1
OVER 4'-6" UP TO 8'-0"(2) 912" ML OR BETTER 2 2
UPPER FLOOR HEADER CHART
NOTE: ALL EXTERIOR SHEAR WALLS
ARE TYPE TYP. U.N.O. REFER TO
LATERAL LOAD DESIGN CHART. NO
INTERIOR WALLS ARE DESIGNED AS
SHEAR WALLS.
A
NOTE: THIS SHEAR WALL DESIGN
SUPERCEDES BRACED WALL DESIGN.
UP
P
E
R
R
O
O
F
F
R
A
M
I
N
G
&
D
E
T
A
I
L
P
L
A
N