Loading...
HomeMy WebLinkAboutSITE PLAN New SFD 1877 Ptarmigan Trl 2020-04-09# OF BARS, E.W.PAD SIZE 13" - 18"3 - #4 REBAR 19" - 24" 4 - #4 REBAR 25" - 30" 5 - #4 REBAR 31" - 36" 6 - #4 REBAR 37" - 42"7 - #4 REBAR NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. AN OPEN HOLE OBSERVATION IS REQUIRED. = SIMPSON STHD14 SHOWN AT APPROXIMATE LOCATION FO U N D A T I O N P L A N LATERAL LOAD DESIGN CHART - ANY HEADERS OR COLUMNS SHOWN ON THIS PLAN SUPERSEDE THIS CHART. - ANY HEADERS THAT WILL BE BEARING BEAMS OR GIRDER TRUSSES THAT ARE NOT SHOWN ON THIS PLAN SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER. HEADERS MAY NOT BE DESIGNED TO SUPPORT GIRDER TRUSS, OR OTHER, POINT LOADS. -NON BEARING HEADERS COULD BE 2-2x10 HF, OR BETTER (1T, 1K) UP TO 4'-6"(2) 2x12 HF#2 OR BETTER OPENING SIZE MIN. HEADER SIZE 2x TRIMMERS 2x KINGS 1 1 OVER 4'-6" UP TO 8'-0"(2) 912" ML OR BETTER 2 2 MAIN FLOOR HEADER CHART NOTE: ALL EXTERIOR SHEAR WALLS ARE TYPE TYP. U.N.O. REFER TO LATERAL LOAD DESIGN CHART. NO INTERIOR WALLS ARE DESIGNED AS SHEAR WALLS. A NOTE: THIS SHEAR WALL DESIGN SUPERCEDES BRACED WALL DESIGN. BEAM TO POST CONNETION DETAIL SCALE: N.T.S. POST BASEPOST CAPPOST SIZE INSTALL PER MANUFACTURERS SPECIFICATIONS ABU88ZPC8Z8x8 SIMPSON, OR EQUAL, POST BASE/CAP INSTALLATION DETAIL SCALE: N.T.S. UP P E R F L O O R A N D L O W E R RO O F F R A M I N G P L A N GENERAL NOTES FOUNDATION WALL DETAIL SCALE: N.T.S. EXTERIOR PAD DETAILINTERIOR PAD DETAIL SCALE: N.T.S.SCALE: N.T.S. PORTAL FRAME DETAIL SCALE: N.T.S. OVER CONCRETE OR MASONRY BLOCK FOUNDATION OVER RAISED WOOD FLOOR - FRAMING ANCHOR OPTION (WHEN PORTAL SHEATHING DOES NOT LAP OVER RIM JOIST) INTERIOR FRAME WALL/FOOTING DETAIL SCALE: N.T.S. ROOF BEAM TO POST CONNETION DETAIL SCALE: N.T.S. LATERAL LOAD DESIGN CHART - ANY HEADERS OR COLUMNS SHOWN ON THIS PLAN SUPERSEDE THIS CHART. - ANY HEADERS THAT WILL BE BEARING BEAMS OR GIRDER TRUSSES THAT ARE NOT SHOWN ON THIS PLAN SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER. HEADERS MAY NOT BE DESIGNED TO SUPPORT GIRDER TRUSS, OR OTHER, POINT LOADS. -NON BEARING HEADERS COULD BE 2-2x10 HF, OR BETTER (1T, 1K) UP TO 4'-6"(2) 2x12 HF#2 OR BETTER OPENING SIZE MIN. HEADER SIZE 2x TRIMMERS 2x KINGS 1 1 OVER 4'-6" UP TO 8'-0"(2) 912" ML OR BETTER 2 2 UPPER FLOOR HEADER CHART NOTE: ALL EXTERIOR SHEAR WALLS ARE TYPE TYP. U.N.O. REFER TO LATERAL LOAD DESIGN CHART. NO INTERIOR WALLS ARE DESIGNED AS SHEAR WALLS. A NOTE: THIS SHEAR WALL DESIGN SUPERCEDES BRACED WALL DESIGN. UP P E R R O O F F R A M I N G & D E T A I L P L A N